Preview only show first 10 pages with watermark. For full document please download

Crc220 Card Insert Riro V3.indd

   EMBED


Share

Transcript

Note 2 V+ (12v) 0v Clock/D1 Data/D0 LED Capture Note 2 0v 12vdc Note 1 V+ (12v) 0v Clock/D1 Data/D0 LED Capture N/O N/C Com Tamper Arming Reader 1 Arming Reader 2 Fire Alarm 0v Input 5 Input 6 Input 7 Input 8 0v 12v Out Tamper / Door 1 Fault Door 2 Fault Output 3 Output 4 5v Out Use for powering 5v readers D+ D0v D+ D0v N/O N/C Com 0v REX 1 Door Mon 1 0v REX 2 Door Mon 2 Note 3 Notes: 1. The reader wiring shown is for a standard format Nortech reader (MP1-EM1-0000) configured for Wiegand format. For other readers, refer to the reader manual. 2. The power supply to readers at the reader interfaces is fixed at 12v dc. Ensure that this is appropriate for the reader(s) that you wish to connect to the controller. If the reader requires a 5v dc supply, connect the +v power lead to the 5v pin on the opposite edge of the PCB. 3. The maximum distance between 1st and last device = 1,200m. Use 2 twisted pair screened cable such as Belden 9729. Use 1 twisted pair for D+ and Dand the other twisted pair for signal ground. Connect the screen to ground at one end only. Other twisted pair screened cables such as CAT5 may be used as long as all unused pairs are connected to ground at one end (same as screen). Node Selection DIP Switches 1 to 5 are used to set the node address in binary format: 5 4 3 2 1 5 4 3 2 1 5 4 3 2 1 =Node 0, =Node 1, 5 4 3 2 1 =Node 2, = Node 3, etc. DOC0056 V3.0