Transcript
nnnnnEPP
POWER QUALITY ANALYSIS
EPPE CX Power Quality
Power Quality Analysis – EPPE CX
EPPE C8 Outstanding features of the EPPE C8 include…
Intuitive operation with 5" TFT graphical touch screen
IEC 61850 protocol Parametrisation via USB stick Integrated web server Multi-client capability 2-GB internal flash memory Multi-processor system
Power Quality Analysis – EPPE CX
EPPE C8 Outstanding features of the EPPE C8 include…
Integrated energy meter Numerous communication interfaces
Direct current measurement up to 40A
Time synchronisation via GPS, DCF, NTP, PC-time
12 binary inputs, 8 relay outputs …..
Power Quality Analysis – EPPE CX
EPPE CX – What´s new?
New design Improved performance Increased computing capacity Various measurement models Integrated sensor card (PV systems, wind power plants, industrial plants)
Replaceable measurement data memory
6 current inputs (differential current measurement)
Power Quality Analysis – EPPE CX
EPPE CX
Model 1 (the same as before): 4 current inputs 4 voltage inputs Can monitor one voltage system Direct current measurement up to 40A for an unlimited period
Numerous interfaces for communication and time synchronisation
+ Replaceable measurement data memory
Power Quality Analysis – EPPE CX
EPPE CX
Model 2
8 voltage inputs - 8 x 600 V - 4 x 600 V / 4 x 2 V
Can monitor two voltage systems - Cost optimization - Monitoring complies with EN50160
Current clamps/sensors can be connected
Power Quality Analysis – EPPE CX
Applications
Current sensors
Connection for current sensors -Circuit does not have to be interrupted - Freely selectable measuring ranges (z.B. 0-10A, 3000A, 10000A)
Power Quality Analysis – EPPE CX
EPPE CX
- Sensor card -
Additional sensor card
High flexibility Various sensors can be connected - Temperature, light irradiation, wind speed,…
Control of external machines / plants (equipment)
Differential current measurement …
Power Quality Analysis – EPPE CX
EPPE CX
- Sensor card -
4 analog inputs Sampling rate 30KHz Measuring ranges: - 300 Vrms (voltage measurement, sensors) - 10 V (sensors) - 2 Vrms (current clamps / sensors) - 20 mA (sensors)
4 analog inputs Sampling rate 100Hz Measuring ranges: - 10 V (sensors) - 2 Vrms (current clamps / sensors)
Power Quality Analysis – EPPE CX
EPPE CX
- Sensor card -
2 direct temperature inputs
1 analog output
Sampling rate: 100Hz
Type: PT 100
Adjustable output to drive other systems Selectable output signal: - 10 V - 20 mA
Power Quality Analysis – EPPE CX
Application
Application example EN50160 (Low Cost) U1, U2, U3, U (EN)
Ethernet
GPS PE
N
L1
L2
L3
PE
N
L1
L2
L3
Binary signals
U1, U2, U3, U (EN)
Power supply
Power Quality Analysis – EPPE CX
Application
Application example EN50160 U1, U2, U3, U (EN)
Ethernet
GPS Cabinet temperature Outside temperature
PE
N
L1
L2
L3
PE
N
L1
L2
L3
Sensor card
I1, I2, I3, IN
Power Supply
U1, U2, U3, U (EN)
Power Quality Analysis – EPPE CX
Application
U1, U2, U3, U (EN)
GPS
Ethernet
Application example: PV system
Sensor card Light irradiation
Outside temperature Module temperature Humidity sensor DC Current DC Voltage I1, I2, I3, IN
Power Supply
Power Quality Analysis – EPPE CX
Application
Application example: Wind power plant U1, U2, U3, U (EN) GPS
Sensor card Wind intensity
Wind direction Acoustic noise Rotor oscillation Generator temperature UMTS
Outside temperature
I1, I2, I3, IN
Ethernet
Power Supply
Power Quality Analysis – EPPE CX
Application
Application example: differential current measurement U1, U2, U3, U (EN)
Ethernet Sensor card
GPS I (PE)
Cabinet temperature Outside temperature IN
I1 I2
Power Supply
I3
PE
N
L1
L2
L3
Power Quality Analysis – EPPE CX
EPPE CX
- Overview Analog Inputs -
Analog Model 1
Analog Model 2
•
4 voltage inputs (600V)
•
•
4 current inputs (5A / 40A)
- 4 x 600V
8 voltage inputs
- 4 x 600V or 4 x 2V (current sensors)
Sampling rate 30 KHz
Measurement to IEC 61000-4-30 class A
Resolution 16 Bit
Sensor Card • 4 analog inputs (sampling rate 30KHz)
- Selectable measuring range: 300Vrms / 10V / 2Vrms (current sensors) / 20 mA • 4 analog inputs (sampling rate 100Hz) - Selectable measuring range : 10V / 2Vrms (current sensors)
• 2 temperature inputs • 1 process output
Power Quality Analysis – EPPE CX
EPPE CX 4 x analog inputs (30KHz)
-Overview-
4 x analog inputs (100Hz)
RS232 / RS485 4 x voltage
14 binary inputs
4 x currrent or 4 x voltage
8 relay outputs
Electr. Ethernet
GPSantenna
Opt. Ethernet External time synchronisation (DCF, GPS)
Memory slot USB (passive)
Power supply 2 x temperature inputs
1 process output (U/I)
Intercommuni cation interfaces
Power Quality Analysis – EPPE CX
EPPE CX
- Front -
NEW front design
New layout Advanced display functions 2 additional LEDs NEW
additional EPPE software
-
Basic software Additional expert software
Thank you !!!
Breaker Analysis n Relay Testing n Digital Fault Recording n Meter Testing n Power Quality Analysis n Optical Measurement n
© T. Wild