Transcript
Prices as of October 21, 2015. Check Web site for most current prices.
General Purpose Midget Class MEQ Fuses Features
Company Information Terminal Blocks Power Distribution Blocks
MEQ Specifications
• Compact dimensions • Fiber tube construction • Time-delay allows harmless inductive surges to pass without needless fuse opening
Applications • Supplemental protection of transformers, solenoids, and other high- inrush circuits • For motor branch circuit applications, refer to EDCC fuses
Wiring Accessories
Time-Delay Voltage Rating: MEQ - 500 VAC Ampere Rating: 0.25 - 30 Amps
ZIPLink Connection System
Interrupting Rating: 10,000 RMS Amps
Multi-wire Connectors
Agency Approvals
Sensor Cables and Connectors
• (0.25 - 30) UL Listed, File E162443 • (0.25 - 30) CSA Certified C22.2, Part 59.2, LR700489 • CE Compliant
M12 Junction Blocks Panel Interface Connectors
MEQ General Purpose Midget Class Fuses
$65.00
MEQ1-5 1.5
$70.00
MEQ2
$65.00
MEQ2-5 2.5
$70.00
MEQ3
$65.00
3
MEQ3-5 3.5
$75.00
MEQ4
$65.00
4 10
0.2 lb
40
$65.00
MEQ7
7
$70.00
MEQ8
8
$65.00
MEQ10 10
$65.00
MEQ12 12
$65.00
MEQ15 15
$65.00
MEQ20 20
$65.00
MEQ25 25
$65.00
MEQ30 30
$65.00
DC Converters
20
8
6
Power Supplies
30
$65.00
MEQ6
Wire Management Products
60
10
5
Bulk Multi-conductor Cables
80
$81.00
MEQ5
AMPERE RATING
100
Transformers and Filters Circuit Protection
6
Tools
4 TIME IN SECONDS
2
Wire
7. 5
1
5
MEQ1
1
$70.00 0.5
0.5
Cable Ties
Characteristic Curves
$75.00
MEQ-5
MEQ4-5 4.5
Wiring Duct
Package Price Weight
3
Part AMP Pcs/ Number Rating Pkg MEQ-25 0.25
3
Test Equipment
2 Enclosures Enclosure Climate Control
1 0.8 0.6
Safety: Electrical Components
0.4
Safety: Protective Wear
0.3 0.2
DIMENSIONS
Terms and Conditions
0.1
Amps
Ferrule (in)
Length (in)
0.08
0.25 - 30
13/32
1-1/2
0.06 0.04 0.03
CROSS REFERENCE
0.02
200
80 100
60
40
30
20
8 10
6
4
0.01
3
FLQ
2
ATQ
0.8 1
FNQ
0.4
MEQ
0.6
EDISON BUSSMANN GOULD LITTELFUSE
RMS SYMMETRICAL CURRENT IN AMPERES Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-169
Prices as of October 21, 2015. Check Web site for most current prices.
Selection Guide Line Overview
Company Information Terminal Blocks
The fuse selection guide below is a general summary of the specifications included for each fuse type. This selection guide does not include the many variables that can exist for specific situations such as local codes, unusual temperature, or other operating conditions. When selecting fuses, be sure to comply with any applicable PUBLIC SAFETY standards that apply to Overcurrent Protection Devices (OPD).
The Edison family of fuses, fuse blocks and fuse holders is divided into two classes: 1. Current Limiting: Class CC, Class J, Class L, Class RK, Class T 2. General Purpose: Class M Midget and Small Dimension
Edison Fuses Selection Guide and General Specifications Description
Class J Fuse Type Fast-Acting Time-Delay Part Number JHL JDL Voltage Rating Amp Rating Interrupting Rating Current Limiting
Agency Approvals
Dimensions
600VAC 450VDC
Current Limiting Class RK1 Class T
Class RK5
Time-Delay
ECNR
ECSR LENRK LESRK
TJN
250VAC 250VAC VDC* 125VDC* 600VAC 125 600VAC 600VAC 300VAC (1-200A) 300VDC* (10-60A) 300VDC* 160 VDC 300VDC* 250VDC* 250VDC* (15-600A) (201-600A) (70-600A)
1 - 600
1 - 600
3 - 600
10 - 600
5 - 600
Class CC
Fast-Acting Fast-Acting
TJS
LCU
HCLR
600VAC
600V
600VAC 300VDC (15-20A)
1 - 600
601 - 1200
Time-Delay
HCTR
0.5 - 30
EDCC
600VAC 600VAC 300VDC (0.5-2.25A) (20–30A) 0.25 - 30
0.5 - 30
Class RK5
Class RK1
Class T
Class L
* Self-certified DC ratings
Edison Fuses Selection Guide and General Specifications General Purpose – Midget
Fuse Type
Fast-Acting
Part Number Voltage Rating
MCL
MOL
Time-Delay
MEQ
MEN
250 VAC to 30A) 600 VAC 250 VAC 500 VAC 250 VAC (0.5 125VDC: (0.5 to 30A)
Amp Rating 0.5 to 50 0.5 to 30 0.25 to 30 0.5 to 30 Interrupting 100,000 10,000 RMS Amps RMS Amps Rating Current N/A Limiting
Agency Approvals
ABC
UL Listed to 248.14, File E162443 CSA Cert. C22.2 Part 59.2, LR 700489
0.5 to 30
Fast-Acting Glass
AGC
GMA
250VAC: 250VAC (0.1 to 10A) (0.063 - 3A) 32VAC: 125VAC (15 to 30A) (4 - 15A) 0.10 to 30
0.063 to 15
Medium Time- Time-Delay Time-Delay Fast-Acting Delay Glass Ceramic Glass Glass
S500
TimeDelay Glass
GMC
MDA
MDL
S506
250VAC (0.5 - 3A) 125VAC (4 - 10A)
250VAC 125VDC (20A)
250VAC: (0.0625 to 8A) 32VAC: (10 to 20A)
250VAC
250VAC
0.5 to 10
0.5 to 20
0.0625 to 20
0.032 to 10
0.25 to 6.3
See specifications table on product pages
UL Listed standard 248-14 UL Listed Guide and File nos. Designed to UL/CSA 248-14 (ABC 0.25-20 A): UL Listed, Guide JDYX, File (AGC 1/100-10 A) E19180 63mA-6A JDYX and E19180 UL Recognition Guide and UL Recognition, Guide JDYX2, File nos. (ABC 20-30A):(AGC File E19180, 7A-15A 11-30) CSA Certified, File JDYX2 and E19180 053787_C_000, CSA Certification Record No: 63mA-6A Class 1422-01 053787 C 000 and Class No: 1422 01 and 1422 30 0.197” x 0.788” (5mm x 20mm)
UL Listed standard 248-14 UL Listed Card: MDA 2/10-20A , MDL 1/16-8A (Guide JDYX, File E19180 UL Recognized Card: MDA 25-30A MDL 9-30A (Guide JDYX2, File E19180) CSA Certification Card: MDA 2/10-15A (Class No. 1422-01)
L Recognized Guide U JDYX2, File E19180 Semko Approval VDE Approval BSI Approval IMQ Approval RoHS compliant
1/4” x 1-1/4”, (6.3mm x 32mm)
0.197” x 0.788” (5mm x 20mm) Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Wiring Duct
Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters
Tools Test Equipment Enclosures
Safety: Electrical Components Safety: Protective Wear Terms and Conditions
N/A
1/4” x 1-1/4”, (6.3mm x 32mm)
Panel Interface Connectors
Enclosure Climate Control
RoHS
Dimensions ferrule (in): 13/32 length (in): 1-1/2
M12 Junction Blocks
Circuit Protection
General Purpose – Small Dimension Electronic Fast-Acting Ceramic
Sensor Cables and Connectors
Wire
Class CC
UL Listed Class J UL Listed Guide JDDZ Class J UL Listed, File E162363 Guide JDDZ UL Listed, Class RK, Guide JDDZ, UL Listed, Class T, Std. 248-10 UL Listed to 248.4, Class CC, CSA Certified File E162363 File E162363 Guide JDDZ, File E162363 CSA Certified, Guide JDDZ, File E162363, HRCI-J per CSA Certified CSA Certified HRCI-R per C22.2, No. 248.12, CSA Certified HRCI-T per HRC-L C22.2 certified HRCI-MISC per C22.2 C22.2, HRCI-J per File 700489 C22.2, No. 248.12, File 53787, No. 248.10, CSA No. 248.8 C22.2, No. (LENRK CSA File 053787) Class 1422-02 & 1422-82 Class 1422-02, No. 248.4, File 700489 File 700489 248.8 File 53787 RoHS File 700489 compliant See product specification pages. ferrule (in): 13/32, length (in): 1-1/2
Description
ZIPLink Connection System
Cable Ties
200,000 RMS Symmetrical Amps Class J
Wiring Accessories
Multi-wire Connectors
Class L
Extremely Fast-Acting
Power Distribution Blocks
Circuit Protection
eCP-143
Prices as of April 15, 2015. Check Web site for most current prices.
Fuse Terminal Blocks
Company Information Terminal Blocks
Fuse blocks are available for 1/4”, 5mm, Class CC and midget size fuses, either with or without a blown fuse LED. LED fuse blocks are polarity sensitive and are 35mm DIN-rail mountable. The hinge side is positive.
” 1/4 ock bl e s Fu /LED w
” 1/4 ock bl e s Fu
m 5m ock bl e s Fu /LED w
m 5m ock ebl s u F
Power Distribution Blocks Wiring Accessories ZIPLink Connection System Multi-wire Connectors
DN-F6 Series: EURO S 10H/35
DN-F6L Series: EURO S 10H/35
DN-F10 Series: EURO S 4LH/35
DN-F10L Series: EURO S 4LH/35
Ordering Information Part Pcs/ Price Part Pcs/ Price Part Pcs/ Price Part Pcs/ Number Pkg Number Pkg Number Pkg Number Pkg 25 $93.00 50 $149.00 DN-F10 DN-F6 – – Gray Terminal Block 7 $20.00 10 $22.75 DN-F6MN DN-F10MN 10 $54.00 10 12-24 VAC/DC* DN-F6L24 DN-F10L24 10 $54.00 – – 110 VAC/DC* DN-F6L110 DN-F10L110 10 10 $54.00 220 VAC/DC* DN-F6L220 DN-F10L220 10 Stripping Length Tightening Torque Density UL Approval** CSA Approval VDE Approval Fuse Size (not supplied) Indicator Type Operating Temperature SCCR Rating CE Conformity Agency File #
Price
$53.00 $53.00 $53.00
Technical Specifications
10 2 10 2 50 20 50 10 50 10 50 500/ 100
Included
DN-R35S1 DN-R35S1-2 DN-R35HS1 DN-R35HS1-2 DN-EB35 DN-EB35MN DN-EB35-A DN-EB35-A-10 DN-QEB35 DN-QEB35-10 DN-ASB1 DN-L*** or various DN-LT**** $28.00 $9.00 $49.50 $12.00 $39.50 $18.00 $28.50 $7.50 $25.50 $7.50 $49.50
10 2 10 2 50 20 50 10 50 10 50 500/ 100
Included
Included 10 2 10 2 50 20 50 10 50 10 50 500/ 100
10 $28.00 DN-R35S1 DN-R35S1 2 $9.00 DN-R35S1-2 DN-R35S1-2 10 $49.50 DN-R35HS1 DN-R35HS1 DN-R35HS1-2 2 $12.00 DN-R35HS1-2 50 $39.50 DN-EB35 DN-EB35 20 $18.00 DN-EB35MN DN-EB35MN 50 $28.50 DN-EB35-A DN-EB35-A DN-EB35-A-10 10 $7.50 DN-EB35-A-10 50 $25.50 DN-QEB35 DN-QEB35 DN-QEB35-10 10 $7.50 DN-QEB35-10 50 $49.50 DN-ASB1 DN-ASB1 DN-L*** or DN-L*** or 500/ various 100 various DN-LT**** DN-LT**** $28.00 $9.00 $49.50 $12.00 $39.50 $18.00 $28.50 $7.50 $25.50 $7.50 $49.50
$28.00 $9.00 $49.50 $12.00 $39.50 $18.00 $28.50 $7.50 $25.50 $7.50 $49.50 various
DN-F6L
DN-F6 / DN-F6MN 10 mm [0.39 in]
DN-F10L
DN-F10 / DN-F10MN
82 mm [3.23 in]
52 mm [2.05 in]
52 mm [2.05 in]
82 mm [3.23 in]
44 mm [1.73 in]
44 mm [1.73 in]
66 mm [2.6 in]
10 mm [0.39 in]
66 mm [2.6 in]
10 mm [0.39 in]
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / t e r m i n a l - b l o c k s
Terminal Blocks
Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters
Tools Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
*Working voltage **For copper wire only ***On lever arm ****On terminal body Note: DN-F6 series fuse holders will accommodate the following AutomationDirect fuses: ABC, AGC, MDA and MDL Series. DN-F10 series fuse holders will accommodate the following AutomationDirect fuses: GMA, GMC, S500, and S506 Series. For more information on accessories, see the DINnectors Accessories section of this chapter.
10 mm [0.39 in]
Cable Ties
Circuit Protection
Accessories Included
Wiring Duct
Wire
12mm [0.47 in] 12mm [0.47 in] 10mm [0.39 in] 10mm [0.39 in] 2.0 N·m [17.7 lb·in] 2.0 N·m [17.7 lb·in] 0.6 N·m [5.3 lb·in] 0.6 N·m [5.3 lb·in] 100/m [30 pcs/ft] 100/m [30 pcs/ft] 100/m [30 pcs/ft] 100/m [30 pcs/ft] 600V 30A 20-6 AWG 600V 30A 20-6 AWG 300V 15A 24-10 AWG 300V 15A 24-10 AWG 600V 30A 18-6 AWG 600V 30A 18-6 AWG 300V 8A 18-12 AWG 300V 8A 18-12 AWG 750V 8A – 750V 8A – 500V 8A 4mm² 500V 8A 4mm² 1 1/4” X 1/4” 1 1/4” X 1/4” 5x20mm-5x25mm 5x20mm-5x25mm Non-indicating LED blown fuse indicator Non-indicating LED blown fuse indicator Ambient air temperature: -20°C to 85°C [-4°F to 185°F] / Relative humidity: 50% max at 40°C [104°F]; 90% max at 20°C [68°F] 10kA per Table SB4.1, 2009, UL 508A, Maximum short circuit current rating for unmarked components CE (EN 60947-1 / 60947-7-3) UL E179129 / LR84816
DN-R35S1 DN-R35S1-2 DN-R35HS1 DN-R35HS1-2 DN-EB35 DN-EB35MN DN-EB35-A End Brackets DN-EB35-A-10 DN-QEB35 DN-QEB35-10 Angled Support Bracket DN-ASB1 or Marking Tags DN-L*** DN-LT****
M12 Junction Blocks Panel Interface Connectors
Note: To obtain the most current agency approval information, see the Agency Approval Checklist section on the specific part number's web page.
End Covers 7.5 mm high 35mm DIN Rail 15mm high
Sensor Cables and Connectors
eTB-57
Prices as of October 21, 2015. Check Web site for most current prices.
Fuse Blocks for Class CC and Midget Class Fuses
Company Information Terminal Blocks Power Distribution Blocks
Description
Specifications
These panel-mount fuse blocks are for use with Class CC Fuses (Edison EDCC, HCTR and HCLR).
Terminal type: Pressure plate with quick connect terminal Base: Thermoplastic Clips: Bright tin-plated bronze
Wiring Accessories ZIPLink Connection System Multi-wire Connectors
UL Flammability: 94V-0 Ratings: 600 VAC, 30 Amps
Sensor Cables and Connectors
Agency Approvals • UL listed to 512 , Guide IZLT, File 14853 • CSA C22.2 No. 39 Class 6225-01, File LR47235 • CE Compliant
M12 Junction Blocks Panel Interface Connectors Wiring Duct Cable Ties
Part Amps Number BC6031PQ
Poles AWG
Pcs/ Wt. Price Pkg (lbs.)
1
10
BC6032PQ 0.1 to 30 2 BC6033PQ
0.1
$62.00
18 - 8 8
0.16
$77.00
6
0.22
$72.00
3
Wire
CROSS REFERENCE
BC Series Fuseblocks EDISON
OLD EDISON BUSSMANN GOULD LITTELFUSE
BC6031PQ
EMR631-77
BC6031PQ
30321R
L60030C-1PQ
BC6032PQ
EMR632-77
BC6032PQ
30322R
L60030C-2PQ
BC6033PQ
EMR633-77
BC6033PQ
30323R
L60030C-3PQ
Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters
Description
Specifications
These panel-mount fuse blocks are for use with any 13/32” x 1-1/2” Class M Fuses (Edison MCL, MEQ, MEN and MOL).
Terminal type: Pressure plate with quick connect terminal
Tools
Base: Thermoplastic
Test Equipment
Circuit Protection
Clips: Bright tin-plated bronze
Enclosures
UL Flammability: 94V-0 Ratings: 600 VAC, 30 Amps
Enclosure Climate Control
Agency Approvals
Safety: Electrical Components
• UL Recognized to 512, Guide IZLT2, File E14853 • CSA C22.2, No.39, Class 6225-01, File 47235
Safety: Protective Wear Terms and Conditions
CROSS REFERENCE
BM Series Fuseblocks Part Amps Number BM6031PQ
Poles AWG
Pcs/ Wt. Price Pkg (lbs.)
1
10
BM6032PQ 0.1 to 30 2 BM6033PQ
3
0.1
$45.00
18 - 8 8
0.16
$64.00
6
0.22
$59.00
EDISON
OLD EDISON BUSSMANN GOULD LITTELFUSE
BM6031PQ
EM631-44
BM6031PQ
30321
L60030M-1PQ
BM6032PQ
EM632-44
BM6032PQ
30322
L60030M-2PQ
BM6033PQ
EM633-44
BM6033PQ
30323
L60030M-3PQ
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-209
Prices as of October 21, 2015. Check Web site for most current prices.
Fuse Blocks for Class CC and Midget Class Fuses One Pole BC6031PQ
CC Class Dimensions -
3.000" + 0.015"
(76.20mm + 0.38mm)
1 POLE
0.828" + 0.015"
inches(mm)
(21.03mm + 0.38mm)
0.360"
(9.14mm)
0.200" + 0.003"
(5.08mm + 0.08mm)
Two Pole BC6032PQ 2 POLE
0.425"
(10.80mm)
1.625" + 0.015"
0.765"
(41.28mm + 0.38mm)
(19.43mm)
0.200" + 0.003"
(5.08mm + 0.08mm)
Three Pole
3BC6033PQ POLE
0.425"
(10.80mm)
1.530"
2.375" + 0.015"
(38.86mm)
(60.33mm + 0.38mm)
0.200" + 0.003"
(5.08mm + 0.08mm)
Buss ®
BC6031PQ 1.210" + 0.015"
(30.73mm + 0.38mm)
Dimensional Data
30A
BUSSMANN COOPER INDUSTRIES ST. LOUIS, MO 63178 MADE IN U.S.A.
600V
CLASS CC FUSES ONLY
75 C WIRE 200,000A RMS SYM WITHSTAND RATING
CU ONLY 10 AWG 20 LBJN.
R
0.77"
M Class Dimensions
(19.4mm)
0.36"
1.22"
(9.1mm)
(31.0mm)
1.53"
(38.9mm)
0.42"
(10.7mm)
0.42"
(10.7mm)
inches(mm)
3"
(76.2mm)
1.5"
(38.1mm)
0.86"
(21.8mm)
1.63"
2.38"
(41.3mm)
One Pole BM6031PQ
(60.3mm)
Two Pole BM6032PQ
Three Pole BM6033PQ
Book 3 (14.3)
eCP-210
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Modular Fuse Holders for Class CC & Midget Class Fuses Features • EHCC Series: High SCCR rated, UL Listed CC holder with indicator option for 600VAC/DC • EHM Series: UL Recognized midget holders • Minimum 90VAC/DC required for illumination • Rated for use with 75°C or 90°C wire, fine stranded wire, spade terminals and comb-bus bars. Use any higher temperature rated wire with appropriate derating. • Complete range of UL Listed and high SCCR rated 1-phase and 3-phase finger-safe comb-bus bars and power feed lugs • Polyester material is UL 94V0 rated, self extinguishing • Multi-phase connections available for ganging up to 4 poles* • Mounts on 35 mm DIN rail • IP20 rated • Spade terminals are accepted (Max width-10mm, Min ID of slot 4mm Max ID of slot 5mm) • Wire ferrules may not be used.
Company Information Terminal Blocks Power Distribution Blocks Wiring Accessories
Agency Approvals/ Standards Class CC • UL File E300536 Guide IZLT Listed • CSA File 47235, Class 6225-01 • CE Compliant • RoHS, Reach
Agency Approvals/ Standards Midget • UL File E300536 IZLT2 Recognized • CSA File 47235, Class 6225-30 • IEC 60269-2 • CE Compliant • RoHS, Reach
EHM Midget Class
UL 600V/30A IEC 690V/32A
• •
• • • ••
EHCC Class CC
UL 600V/30A
2 pole 3 pole 1 pole
••
2 pole
••
3 pole
EHM1DU EHM1DU-12 EHM2DU EHM2DU-6 EHM3DU EHM3DU-4 EHCC1DU EHCC1DU-12 EHCC2DU EHCC2DU-6 EHCC3DU EHCC3DU-4
Cable Ties Wire
Power Supplies
Transformers and Filters Circuit Protection Tools
Pkg. Wt. (lb.)
Price
1
0.12
$8.00
12
1.42
$75.00
1
0.24
$16.50
6
1.42
$78.00
1
0..36
$25.00
4
1.42
$79.00
1
0.12
$9.25
12
1.42
$88.00
1
0.24
$19.00
6
1.42
$90.00
1
0.36
$29.00
4
1.42
$91.00
Test Equipment
Fuse Holder with NEON Indication
Product Weight (lb.)
Box Qty.
Price
EHM1DIU EHM1DIU-12 EHM2DIU EHM2DIU-6 EHM3DIU EHM3DIU-4 EHCC1DIU EHCC1DIU-12 EHCC2DIU EHCC2DIU-6 EHCC3DIU EHCC3DIU-4
0.12
1
$10.75
1.42
12
$101.00
0.24
1
$21.50
1.42
6
$103.00
0.36
1
$32.50
1.42
4
$106.00
0.12
1
$12.00
1.42
12
$114.00
0.24
1
$24.50
1.42
6
$117.00
0.36
1
$37.00
1.42
4
$119.00
* To add additional poles, see multi-pole connection kit JV-L in accessories. One JV-L kit is sufficient to gang up to 4 poles. • UL Recognized, CSA •• UL Listed, CSA
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Wiring Duct
DC Converters
Fuse Holder Box Phase Without Configuration Indication Qty. 1 pole
Panel Interface Connectors
Wire Management Products
Modular Fuse Holder Selection Table
•
Sensor Cables and Connectors
Bulk Multi-conductor Cables
• EHM: Edison MCL, MOL, MEQ, MEN, or midget fuses • EHCC: Edison HCLR, HCTR, EDCC fuses, or class CC fuses
UL
Multi-wire Connectors
M12 Junction Blocks
Application
Max Series Voltage & IEC Size Current
ZIPLink Connection System
Circuit Protection
eCP-211
Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Prices as of October 21, 2015. Check Web site for most current prices.
Modular Fuse Holders for Class CC & Midget Class Fuses Modular Fuse Holder Specifications Part Number Part Number w/o Indication w/ Indication EHM1DU EHM1DIU EHM1DU-12 EHM1DIU-12 EHM2DU EHM2DIU EHM2DU-6 EHM2DIU-6 EHM3DU EHM3DIU EHM3DU-4 EHM3DIU-4 EHCC1DU EHCC1DIU EHCC1DU-12 EHCC1DIU-12 EHCC2DU EHCC2DIU EHCC2DU-6 EHCC2DIU-6 EHCC3DU EHCC3DIU EHCC3DU-4 EHCC3DIU-4
Holder Max Voltage Number Size & Current of poles
Wire Range
Maximum Operating SCCR Terminal Flammability Torque Temperature Rating Rating Rating
1 EHM Midget Class and 10x38
UL/CSA 600V/30A IEC 690V/32A
100kA rms sym
2 3 1
EHCC Class CC
UL/CSA 600V/30A
18-4 AWG (0.8-21 mm²)
30 lb-in (3.4 N•m) maximum
-20˚C to +90˚C -4˚F to 194˚F (indicating) -20˚C to +120˚C -4˚F to 248˚F (non-indicating) 200kA rms sym
2
Solid, Stranded, Fine stranded, Spade lug, UL 94V0 Comb-bus bar; self-extinguishing Single and dual wire; 75˚C and 90˚C Cu wire
3
CHCC and EHM Wire Range, Type and Torque Wire Range
Conductor Type
18-14 AWG (0.8-2.0 mm²) 18-16 AWG (0.8-1.3 mm²)
Solid, Stranded
14-10 AWG (2.0-5.2 mm²)
Number of Conductors
Torque
Single
20 lb-in (2.3 N•m)
Dual
25 lb-in (2.8 N•m)
12-10 AWG (3.3-5.2 mm²) 8-4 AWG (8.3-21.1 mm²)
Stranded, Fine Stranded
18-14 AWG (0.8-2.0 mm²)
Spade Terminal
N/A
Comb Bus
Single
30 lb-in (3.4 N•m)
Fuse Holder Dimensions mm [inches]
EHM Midget Class / EHCC Class CC
Book 3 (14.3)
eCP-212
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Accessories Accessories Part Number
Description
FP-2
Fuse puller for fuse dia. 13/32” - 13/16”. Fuse type: 0-60A, 250V; 0-30A, 600V Multi-pole connection kit to connect new design multiple Class CC and Midget Class fuse holders together. Kit consists of 6 connectors and 3 handle pins to connect up to 4 fuse holders.
JV-L* (Not Field Installable)
Pcs/Pkg Price 1
$16.00 $6.25
Note: Will not work with retired design fuse holders shipped before November 1, 2009. *Roll pin punch or installation tool is required to install handle pins (Tool not sold by Automationdirect.com).
FP2
Handle Pin Dimensions Diameter = 0.0625 in [1.58 mm] Length = 0.632 in [16.07 mm]
JV-L JV-L
Book 3 (14.3)
eCP-218
Circuit Protection
1 - 8 0 0 - 633 - 0 4 0 5
Prices as of October 21, 2015. Check Web site for most current prices.
Cross Reference Guide
Company Information Terminal Blocks Power Distribution Blocks
CROSS REFERENCE GUIDE By manufacturers type reference or series number. Ampere ratings must be added for ordering purposes. FUSE TYPE
VOLT EDISON
BRUSH/ BUSSMANN MERSEN / GEC/CEFCO LITTELFUSE DORMAN GOULD
UL CLASS CURRENT LIMITING FUSES (CSA CLASS) CC (HRCI-CC)
Time-Delay
600
EDCC
–
LP-CC
ATDR
–
CCMR
Time-Delay
600
HCTR
–
FNQ-R
ATQR
–
KLDR
Fast-Acting RK1 RK5 J T
Time-Delay Dual Element Time-Delay Dual Element
600
HCLR
HCLR
KTK-R
ATMR
CTK-R
KLKR
250
LENRK
–
LPN-RK-SP
A2DR
–
LLNRK
600
LESRK
–
LPS-RK-SP
A6DR
–
LLSRK
250
ECNR
–
FRN-R
TR
–
FLNR
600
ECSR
–
FRS-R
TRS
–
FLSR
JDL
–
LPJ
AJT
–
JTD
Time-Delay Dual Element 600 High-Speed AC Drive Extremely Fast-Acting
600
JHL
–
DFJ
HSJ
–
–
300
TJN
–
JJN
A3T
–
JLLN
600
TJS
–
JJS
A6T
–
JLLS
Midget
1/4”x1/4” Ceramic 1/4”x1/4”Glass 1/4”x1/4” Ceramic 1/4”x1/4”Glass 5x20 mm Glass 5x20 mm Glass
600
MCL
MCL
KTK
ATM
CTK
KLK
250
MOL
MOL
BAF/BAN
OTM
–
BLF
500
MEQ
MEQ
FNQ
ATQ
–
FLQ
MEN
MEN
FNM
TRM
–
FLM
250/125 ABC
ABC
ABC
GAB
–
314
250/32 AGC
AGC
AGC
GGC
–
312
250
MDA
MDA
MDA
–
–
326
250/32 MDL
MDL
MDL
GDL
–
313
Fast-Acting
250/125 GMA
GMA
GMA
GGM
–
235
Medium Time-Delay
250/125 GMC
GMC
GMC
GSC
–
–
Fast-Acting
250
S500
BDB
GDB
GSB
–
217
Time-Delay
250
S506
BDC
GDC
GDG
–
218
FP-2
–
–
–
Fast-Acting Time-Delay
–
old - 38072 – new - FP-2
Sensor Cables and Connectors M12 Junction Blocks
Wiring Duct Cable Ties
Bulk Multi-conductor Cables Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Tools
Fuse Puller Fuse Puller FP-2
Multi-wire Connectors
Wire
250
Time-Delay
ZIPLink Connection System
Panel Interface Connectors
UL CLASS GENERAL PURPOSE FUSES Fast-Acting
Wiring Accessories
Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Terms and Conditions
Book 3 (14.3)
w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n
Circuit Protection
eCP-219