Transcript
AM DIRECTIONAL ANTENNA PHASING SYSTEMS
“LTU SERIES LINE TERMINATING UNITS”
ALUMINUM CONSTRUCTION PRE-FABRICATED BUILDINGS ADVANTAGES OF PRE-FAB CONSTRUCTION
When it come to AM directional antenna (DA) systems, Kintronic Laboratories, Inc. (KTL) embodies complete design, manufacturing and installation capabilities. From the transmitter output port, KTL can supply all of the antenna system equipment necessary to put your station on the air.
• All Aluminum Construction - No Rust or Corrosion • Minimal Installation Time and Expense • Tailor-made to the Customer’s specificatinos • Maximum Exterior Building Dimensions: 12 ft.W x 30 ft. L x 10 ft. H • Lightweight aluminum construction to yield optimum transportability • Provisions for lifting by boom truck equipment • in the case of AM broadcast tuning and matching, all networks arrive pre-tuned to theoretical values • Versatile for broadcast, cellular, PCS, paging and many other applications • Suitable for shipment worldwide
WEATHERPROOF HOUSING
A DA system is typically comprised of three major elements: 1. Common point, phasing and power dividing equipment configuration options • single or multi-cabinet • open panel and shelf 2. Line terminating units (LTUs) options • weatherproof REAR VIEW OF DIRECTIONAL ANTENNA PHASOR CABINET • wall mountable open panel and shelf 3. Transmitter and/or pattern selection controller options • Electromechanical relay-type • Programmable Logic Controller (PLC) with Touch Screen Interface
CUSTOM AM/MW MULTIPLEXING SYSTEMS
MODEL*
XMTR. POWER/ FREQ. BAND
LTU-1B-550 LTU-1B-1600 LTU-2.5B-550 LTU-2.5B-1600 LTU-5B-550 LTU-5B-1600 LTU-10B-550 LTU-10B-1600 LTU-12B-550 LTU-12B-1600
1KW/550-1000 KHz 1KW/1010-1600 KHz 2.5KW/550-1000 KHz 2.5KW/1010-1600 KHz 5KW/550-1000 KHz 5KW/1010-1600 KHz 10KW/550-1000 KHz 10KW/1010-1600 KHz 12KW/550-1000 KHz 12KW/1010-1600 KHz
LTUOP-1B-550 LTUOP-1B-1600 LTUOP-2.5B-550 LTUOP-2.5B-1600 LTUOP-5B-550 LTUOP-5B-1600 LTUOP-10B-550 LTUOP-10B-1600 LTUOP-12B-550 LTUOP-12B-1600
1KW/550-1000 KHz 1KW/1010-1600 KHz 2.5KW/550-1000 KHz 2.5KW/1010-1600 KHz 5KW/550-1000 KHz 5KW/1010-1600 KHz 10KW/550-1000 KHz 10KW/1010-1600 KHz 12KW/550-1000 KHz 12KW/1010-1600 KHz
MODEL*
*Weatherproof Housing and Open Panel sold without meter. Base current meters are optional
Kintronic Laboratories, Inc. offers custom AM/MW multiplexing systems for omni-directional or directional antenna applications. Complete system integration services from concept to operation are available from KTL: 1.Site planning and building layouts utilizing state-of-the art CAD. 2.Computer modeling to yield oprimum isolation and bandwidth. 3.Complete system fabrication facilities. 4.Personnel to supervise and assist in on-site equipment installation. 5.Technical staff and large component inventory to provide long-term maintenance support. CUSTOM AM/MW DIPLEXER IN WEATHERPROOF ENCLOSURE
www.kintronic.com FAX (423) 878-4224
Email: ktl@kintronic .com
AM/MW RADIO BROADCAST ANTENNA SYSTEMS AND ACCESSORIES FOR THE DIGITAL REVOLUTION
MAIL: P.O. BOX 845 • BRISTOL, TN 37621 • PHONE (423) 878-3141
SHIPPING: 144 PLEASANT GROVE RD., BLUFF CITY, TN 37618
RF PATCH PANEL SERIES
VARIABLE ARC GAP
DL-10-158EIA** DL-10-158CC** DL-10-7B** DL-10-LCF** DL-20-158EIA** DL-20-158CC** DL-20-7B** DL-25-318EIA* DL-25-7B*
STOCK #
DESCRIPTION
AG-1-2701
Adjustable Nickel-plated Brass Horn Gap For Installation On LTU With 7" Bowl Insulator Adjustable Nickel-plated Brass Horn Gap For Installation On LTU With 5" Bowl Insulator Adjustable Arc Gap Adjustable Arc Gap For High Voltage Tower Applications Adjustable Ball Gap With 1" Balls High Voltage Adjustable Ball Gap with 2" Balls Extra High Voltage Adjustable Ball Gap with 2-3/4” Balls Ultraviolet Arc Detector in Wall Mountable Shielded Housing
AG-1-306 AG-2 AG-2-HV AG-3 AG-3-HV AG-3-XHV ARCDET
RIGID TRANSMISSION LINE & ACCESSORIES
DL-50-318EIA* DL-50-7B* DL-100-318EIA* DL-200-618EIA* DL-250-618EIA DL-300-8316EIA DL-600-9316EIA
ISOLATION INDUCTORS & HOUSINGS/PANELS
ISOLATION COIL HOUSING
RIGHT: MODEL CB-200X
Stock # IC-FSJ1-50S
RF SAMPLING LOOP
MODEL CB-100X
INPUT POWER (KW)/CONNECTOR
DL-1-12CC DL-1-NF DL-1-UHFF DL-2-12CC** DL-5-78 EIA** DL-5-78CC** DL-5-5B**
EQUIPMENT FOR ANCILLARY ANTENNA OR SAMPLING LOOP ISOLATION ON AM/MW BROADCAST TOWER KTL VERSATILE ISOCOUPLERS (FM/VHF/UHF ISOLATION TRANSFORMERS)
AM/MW DUMMY LOADS
OPEN PANEL
PHASE SAMPLING LOOPS
AM/MW TRANSMITTER COMBINER/PARALLELING UNIT SERIES
1/ 1/2" Cable Clamp 1/ Type N Female 1/ Type UHF Female 2/ 1/2" Cable Clamp 5/ 7/8" EIA Flange 5/ 7/8" Cable Clamp 5/ 5" Porcelain Bowl Insulator 10/ 1-5/8" EIA Flange 10/ 1-5/8" Cable Clamp 10/ 7" Porcelain Bowl Insulator MODEL DL-5/10/20 (SHOWN WITH OPTIONAL SWITCH 10/ Female LC 20/ 1-5/8" EIA Flange 20/ 1/ 1-5/8" Cable Clamp 20/ 7" Porcelain Bowl Insulator 25/ 3-1/8" EIA Flange 25/ 7" Porcelain Bowl Insulator 50/ 3-1/8" EIA Flange 50/ 7" Porcelain Bowl Insulator 100/ 3-1/8" EIA Flange 200/ 6-1/8" EIA Flange 250/ 6-1/8" EIA Flange MODEL DL-25/50 300/ 8-3/16" EIA Flange 600/ 9-3/16" EIA Flange NOTE: Power Rating Is
Carrier Power + 140% Mod. *These Include Input Toroidal Current Meter. **Supplied with optional transmitter to dummy load or antenna manual selection switch.
MAIN/AUXILARY/DUMMY SWITCHING UNITS
STOCK #
DESCRIPTION
CB-5X CB-10X CB-20X CB-50X CB-100X CB-200X
2 2 2 2 2 2
x x x x x x
2.5 KW 5 KW 10 KW 25 KW 50 KW 100 KW
Stock # SLA-5312G SLA-5312I SLSS-5312G SLSS-5312I SLA-8512G SLA-8512I SLSS-8512G SLSS-8512I SL-SB-A SL-SB-SS SLC-N
WEATHERPROOF ANTENNA TUNING UNIT HOUSING
STOCK #
UNPAINTED LTU BOXES
LTU-1U LTU-2U LTU-3U
32"W x 20"D x 28"H 36"W x 24"D x 32"H 40"W x 27"D x 35"H
NOTE: Bowl Insulator and Stand are optional
Description Aluminum Angle, 53"H x 12"D, Grounded Aluminum Angle, 53"H x 12"D, Insulated Stainless Steel, 53"H x 12"D, Grounded Stainless Steel, 53"H x 12"D, Insulated Aluminum Angle, 85"H x 12"D, Grounded Aluminum Angle, 85"H x 12"D, Insulated Stainless Steel, 85"H x 12"D, Grounded Stainless Steel, 85"H x 12"D, Insulated Aluminum Shorting Bar Stainless Steel Shorting Bar Replacement Connector Assembly (Specify UHF or Type N) OTHER SIZES AVAILABLE ON REQUEST.
SINGLE POINT BULKHEAD GROUND PANELS STOCK # PAINTED LTU BOXES
KTL manufactures a complete line of Single Point Bulkhead Ground Panels to provide a shunt path to ground for any lightning-induced transients that occur on a tower or tower array. These panesl consist of an Aluminum Wall Insert with a Weatherproof Boot Panel on the exterior side and a Brass Ground Panel on the interior side.
INTERIOR
LTU-1P 32"W x 20"D x 28"H LTU-2P 36"W x 24"D x 32"H LTU-3P 40"W x 27"D x 35"H
STOCK #
HEATER
MRH-TCH
Thermostatically Controlled Heater For Any Above Housing
Includes Bowl Insulator Hole and Door Keylock. LTU Boxes Do Not Include Light, Receptacle or Bridge Shelf
Seperate brass ground clamps are provided for each RF and/or sample cable. Barrier strips with appropriatelyrated Metal Oxide Varistors (MOV’s) are provided to terminate each AC power, telephone, or control/monitor conductor that enters the building.
MODEL FMC-30
MODEL FMC-0.1
MODEL FMC-O.2P
Model Description FMC-1.9G-PCS Frequency Range 1.85-2.05 GHZ (Includes Mounting Kit) Maximum Power Rating >30 KV Peak AM Base Voltage FMC-2.4G-SS Frequency Range 2.4-2.5 GHZ (Includes Mounting Kit) Maximum Power Rating >30 KV Peak AM Base Voltage FMC-0.5A Frequency Range 35-87 MHZ Maximum Power Rating 0.5 KW FMC-0.5B Frequency Range 150-699 MHZ Maximum Power Rating 0.5 KW MODEL FMC-1.9G-PCS FMC-0.1 Frequency Range 700-957 MHZ Maximum Power Rating 0.1 KW FMC-0.1X Frequency Range 920-957 MHZ Maximum Power Rating 0.3* KW * Power Rate Decreases to 0.2 KW for 860-920 MHz. FMC-0.1S FMC-0.1 with Customized Bandpass FMC-0.2P Frequency Range 935-985 MHz (Includes Mounting Kit) Maximum Power Rating 0.2 KW FMC-0.2P/S FMC-0.2P with Customized Bandpass FMC-1.0LPTV Frequency Range 174-450* MHZ (LOW POWER TV) Maximum Power Rating 1 KW 7/8" EIA Flange * Higher Frequency Operation Available at Reduced Power Rating. FMC-1.5 Frequency Range 88-149 MHZ Maximum Power Rating 1.5 KW FMC-7.5 Frequency Range 88-108 MHZ (FM BAND) Maximum Power Rating 7.5 KW FMC-20 Frequency Range 88-108 MHZ (FM BAND) Maximum Power Rating 20 KW FMC-30 Frequency Range 88-108 MHZ (FM BAND) Maximum Power Rating 30 KW
Description Andrew 1/4" Foam Dielectric Heliax (Phase Stabilized) IC-LDF2-50 Andrew 3/8" Foam Dielectric Heliax Cable (Phase Stabilized) IC-FLC38-50J Cablewave 3/8" Foam Flexwell (Phase Stabilized) IC-LDF4-50A Andrew 1/2" Foam Dielectric Heliax Cable IC-FLC12-50J Cablewave 1/2" Foam Foam Flexwell IC-FLC78-50J Cablewave 7/8" Foam Foam Flexwell IC-FLC114-50J Cablewave 1-1/4" Foam Foam Flexwell IC-FLC158-50J Cablewave 1-5/8" Foam Foam Flexwell IC-EW64 Andrew Heliax Elliptical Waveguide (5.3-7.75 GHz) IC-B1 Aluminum Box 30"W x 30"D x 35"H for 1/4" & 3/8" IC-B2 Aluminum Box 30"W x 30"D x 47"H for 1/2" IC-B3 Aluminum Box 48"W x 50"D x 47"H for 7/8" IC-B4 Aluminum Box 60"W x 60"D x 54"H for 1-5/8" IC-B5 Aluminum Box 52"W x 46"D x 54"H for EW64 IC-P1 Aluminum Panel 24"W x 30"H for 1/4" & 3/8" IC-P2 Aluminum Panel 30"W x 40"H for 1/2" IC-P3 Aluminum Panel 48"W x 48"H for 7/8" or EW64 IC-P4 Aluminum Panel 56"W x 54"H for 1-1/4" or 1-5/8" Optional Items: Variable Vacuum Capacitor and Mounting Hardware. These items will be specified in accordance with the installation requirements.
CUSTOM MULTI-CONDUCTOR ISOLATION INDUCTORS Stock # MCII-78-7 MCII-118-14 MCII-138-21
Description Slotted 7/8” Copper Tube, 7 Conductors Slotted 1-1/8” Copper Tube, 14 Conductors Slotted 1-3/8” Copper Tube, 21 Conductors
Optional Items: Aluminum Weatherproof Housing Aluminum Knockdown Stand for Housing Amuminum Wall Mountable Open Panel
CUSTOM MULTI-CONDUCTOR ISOLATION INDUCTOR STOCK # MCII-138-21
KINTRONIC LABS EXTERIOR
continues...
MADSH4221154158* RFC-40-20-2-115 RF Contactor 158 Cable Terminating Clamps MADSH4222304158* RFC-40-20-2-230 RF Contactor 158 Cable Terminating Clamps MADSH4221154158E RFC-40-20-2-115 RF Contactor for Four 1-5/8" EIA Flanges MADSH4222304158E RFC-40-20-2-230 RF Contactor for Four 1-5/8" EIA Flanges
and Four CC-
RACK MOUNTABLE CONTROLLERS
and Four CCwith Provision
WEATHERPROOF HOUSING FOR ELECTRONIC EQUIPMENT
RF METER SWITCHES & PANEL
with Provision MODEL MRH-1-60
115 or 230 Volt Contactor Operation *Append Stock No. With E for 7/8" and 1-5/8" EIA Instead of Cable Clamps
RIGID TRANSMISSIION LINES
STOCK #
DESCRIPTION
CK3-78-50
20' Section of 7/8" EIA Transmission Line With No Flanges 20' Section of 1-5/8" EIA Transmission Line With No Flanges 20' Section of 3-1/8" EIA Transmission Line With No Flanges
CK3-158-50 CK3-318-50 MODEL PP-318-7U
STOCK #
DESCRIPTION
PP-78-3U
Three Ports, One U-Link, Two Interlock Microswitches, For 7/8" Line Four Ports, Two U-Links, Four Interlock Microswitches, For 7/8" Line Five Ports, Two U-Links, Five Interlock Microswitches, For 7/8" Line Seven Ports, Three U-Links, Seven Interlock Microswitches, For 7/8" Line Three Ports, One U-Link, Two Interlock Microswitches, For 1-5/8" Line Four Ports, Two U-Links, Four Interlock Microswitches, For 1-5/8" Line Five Ports, Two U-Links, Five Interlock Microswitches, For 1-5/8" Line Seven Ports, Three U-Links, Seven Interlock Microswitches, For 1-5/8" Line Three Ports, One U-Link, Two Interlock Microswitches, For 3-1/8" Line Four Ports, Two U-Links, Four Interlock Microswitches, For 3-1/8" Line Five Ports, Two U-Links, Five Interlock Microswitches, For 3-1/8" Line Seven Ports, Three U-Links, Seven Interlock Microswitches, For 3-1/8" Line Three Ports, One U-Link, Two Interlock Microswitches, For 6-1/8" Line Four Ports, Two U-Link, Four Interlock Microswitches, For 6-1/8" Line Five Ports, Two U-Link, Four Interlock Microswitches, For 6-1/8" Line Seven Ports, Three U-Link, Five Interlock Microswitches, For 6-1/8" Line
PP-78-4U PP-78-5U PP-78-7U PP-158-3U PP-158-4U PP-158-5U PP-158-7U PP-318-3U PP-318-4U PP-318-5U PP-318-7U PP-618-3U PP-618-4U PP-618-5U
Special lengths available on request. Flanges installed on one or both ends are also available RIGID LINE UNPRESSURIZED ELBOW
ACCESSORIES STOCK #
DESCRIPTION
CK13-78 CK13-158 CK13-318 CK18-78-50 CK18-158-50 CK18-318-50 CK25-78-50 CK25-158-50 CK25-318-50 CK4-78-50* CK4-158-50* CK4-318-50* CK45-78-50 CK45-158-50 CK45-318-50 CK5-78-50* CK5-158-50* CK5-318-50* CK11-78 CK11-158 CK11-318 CK23-158-50 CK23-318-50 CK-78-FA CK-158-FA CK-318-FA CK-416-FA CK-618-FA
Fixed Flange, 7/8" EIA (Includes Installation) Fixed Flange, 1-5/8" EIA (Includes Installation) Fixed Flange, 3-1/8" EIA (Includes Installation) Swivel Flange, 7/8" EIA (Includes Installation) Swivel Flange, 1-5/8" EIA (Includes Installation) Swivel Flange, 3-1/8" EIA (Includes Installation) Unpressurized 90 Degree Miter Elbow, 7/8" EIA Unpressurized 90 Degree Miter Elbow, 1-5/8" EIA Unpressurized 90 Degree Miter Elbow, 3-1/8" EIA Pressurized 90 Degree Miter Elbow, 7/8" EIA Pressurized 90 Degree Miter Elbow, 1-5/8" EIA Pressurized 90 Degree Miter Elbow, 3-1/8" EIA Unpressurized 45 Degree Miter Elbow, 7/8" EIA Unpressurized 45 Degree Miter Elbow, 1-5/8" EIA Unpressurized 45 Degree Miter Elbow, 3-1/8" EIA Pressurized 45 Degree Miter Elbow, 7/8" EIA Pressurized 45 Degree Miter Elbow 1-5/8" EIA Pressurized 45 Degree Miter Elbow 3-1/8" EIA Unpressurized Field Flange, 7/8" EIA Unpressurized Field Flange, 1-5/8" EIA Unpressurized Field Flange, 3-1/8" EIA 1-5/8" EIA-to-7/8" EIA Plate Reducer 3/8" EIA-to-1-5/8" EIA Plate Reducer Female Adaptor 7/8" EIA Female Adaptor 1-5/8" EIA Female Adaptor 3-1/8" EIA Female Adaptor 4-1/16" EIA Female Adaptor 6-1/8" EIA
WALL MOUNTABLE MAIN/AUX/ DUMMY SWITCH
RACK MOUNTABLE MAIN/AUX/DUMMY SWITCH
STOCK #
DESCRIPTION
MADSH421115312
RFC-40-20-1-115 RF Contactor and Three CC12 Cable Terminating Clamps RFC-40-20-1-230 RF Contactor and Three CC12 Cable Terminating Clamps RFC-40-20-1-115 RF Contactor and Three CC78 Cable Terminating Clamps RFC-40-20-1-230 RF Contactor and Three CC78 Cable Terminating Clamps RFC-40-20-1-115 RF Contactor with Provision for Three 7/8" EIA Flanges RFC-40-20-1-230 RF Contactor with Provision for Three 7/8" EIA Flanges RFC-40-20-1-115 RF Contactor and Three CC114 Cable Terminating Clamps RFC-40-20-1-230 RF Contactor and Three CC114 Cable Terminating Clamps RFC-40-20-1-115 RF Contactor and Three CC158 Cable Terminating lamps RFC-40-20-1-230 RF Contactor and Three CC1158 Cable Terminating Clamps RFC-40-20-1-115 RF Contactor with Provision for Three1-5/8" EIA Flanges RFC-40-20-1-230 RF Contactor with Provision for Three1-5/8" EIA Flanges RFC-40-20-2-115 RF Contactor and Four CC-12 Cable Terminating Clamps RFC-40-20-2-230 RF Contactor and Four CC-12 Cable Terminating Clamps RFC-40-20-2-115 RF Contactor and Four CC-78 Cable Terminating Clamps RFC-40-20-2-230 RF Contactor and Four CC-78 Cable Terminating Clamps RFC-40-20-2-115 RF Contactor with Provision for Four 7/8" EIA Flanges RFC-40-20-2-230 RF Contactor with Provision for Four 7/8" EIA Flanges RFC-40-20-2-115 RF Contactor and Four CC114 Cable Terminating Clamps RFC-40-20-2-230 RF Contactor and Four CC114 Cable Terminating Clamps
MADSH421230312 MADSH421115378* MADSH421230378* MADSH421115378E MADSH421230378E MADSH4211153114 MADSH42123053114 MADSH4211153158* MADSH4212303158* MADSH4211153158E MADSH4212303158E MADSH422115412 MADSH422230412 MADSH422115478* MADSH422230478* MADSH4221115478E MADSH4221230478E MADSH4221154114
XMTR-ANTENNA-DUMMY OR MAIN-AUXILARYDUMMY SWITCHES IN WALL MOUNTABLE HOUSING 16"D X 24"W X 24"H STOCK #
DESCRIPTION
MADSH8311103158* RFC-80-30-1- XXX RF Contactor and Three CC158 Cable Terminating Clamps MADSH8312203158* RFC-80-30-1-XXX RF Contactor and Three CC158 Cable Terminating Clamps MADSH8311103158E RFC-80-30-1- XXX RF Contactor with Provision for Three 1-5/8" EIA Flanges MADSH8312203158E RFC-80-30-1- XXX RF Contactor with Provision for Three 1-5/8" EIA Flanges MADSH111103318E RFC-100-35-1-XXX RF Contactor With Three 31/8" EIA Female Flanged Ports MADSH112203318E RFC-100-35-1-XXX RF Contactor With Three 31/8" EIA Female Flanged Ports MADSH211153618E RFC-200-30-1- XXX RF Contactor With 6-1/8" EIA Female Flanged Ports MADSH8321104158* RFC-80-30-2-XXX RF Contactor and Four CC158 Cable Terminating Clamps MADSH8322204158* RFC-80-30-2-XXX RF Contactor and Four CC158 Cable Terminating Clamps MADSH8321104158E RFC-80-30-2-XXX RF Contactor with Provision for Four 1-5/8" EIA Flanges MADSH8322204158E RFC-80-30-2-XXX RF Contactor with Provision for Four 1-5/8" EIA Flanges MADSH121104318E RFC-100-35-2-XXX RF Contactor With Four 31/8" EIA Female Flange Terminations MADSH122204318E RFC-100-35-2-XXX RF Contactor With Four 31/8" EIA Female Flange Terminations MADSH221154618E RFC-200-30-2-XXX RF Contactor With Four 61/8" EIA Female Flanged Ports XXX Indicates 110 or 220 Volt Contactor Operation. Please Specify. *Append Stock No. With E for 7/8" and 1-5/8" EIA Instead of Cable Clamps
KINTRONIC LABS PP-618-7U
Other Patch Panel Configurations Are Available Upon Request
*Includes Qty. 2 anchor inner connectors
MADSH4222304114
continues...
PLC CONTROLLER W/TOUCH SCREEN INTERFACE
RACK MOUNTABLE CONTROLLER
FOR MAIN/AUX DUMMY AND PS-1 POWER CUTBACK UNITS STOCK #
DESCRIPTION
PS-C-1R
Controller For 19" Rack/Remote Control Only of MAIN or AUX Transmitter Select and Dry Closure Status. Also Includes Time Adjustable Failsafe Transmitter Switching Logic, Key Operated Interlock Bypass Switch and Socket-Mounted 24VDC Power Supply PS-C-1R/L
Controller For 19" Rack/Local and Remote Control. This Controller Incorporates the Same Features as the PS-C-1R As Well As Front Panel Illuminated Pushbutton Selector Switches for MAIN or AUX Transmitter.
FOR PS-2 AND PS-3 POWER CUTBACK UNITS STOCK #
DESCRIPTION
PS-C-2R PS-2R/L
Controller For Controller For Remote Controller For Controller For and Remote
PS-C-3R PS-C-3R/L
DESCRIPTION
MRH-1-24 MRH-1-36 MRH-1-48 MRH-1-60
22"W 22"W 22"W 22"W
x x x x
29"H, 41"H, 53"H, 65"H,
24" 36" 48" 60"
Rack Rack Rack Rack
Space Space Space Space
DOUBLE-WALL INSULATED WEATHERPROOF RACKS
19" Rack/Three Power Levels/Remote 19" Rack/Three Power Levels/Local
DESCRIPTION
STOCK #
RF METER SWITCHES
STOCK #
DESCRIPTION
MS-1 MS-2 MS-3 MS-4 MS-5 MS-MP
MBB* Type, 60 Amp., For Weatherproof Housing MBB* Type, 60 Amp., For Open Panel MBB* Type, 80 Amp., For Weatherproof Housing MBB* Type, 80 Amp., For Open Panel MBB* Type, 20 Amp., For Weatherproof Housing Meter Panel For Use With MS-1,. MS-3, & MS-5
TOWER LIGHTING & STATIC DRAIN CHOKES
DESCRIPTION
MRH-1-24DW Double-Wall 24"W x 26"D x 33"H, 24" Rack Space MRH-1-36DW Double-Wall 24"W x 26"D x 43"H, 36" Rack Space MRH-1-48DW Double-Wall 24"W x 26"D x 57"H, 48" Rack Space Includes Thermostatically Controlled Fan and Dual AC Recepticle. TOWER LIGHTING CHOKES
STANDARD EQUIPMENT RACK
Programmable Logic Based (PLC) Controller With Color Touch Screen Interface for Directional Arrays. Standard Unit Controls Up to 10 RFC Contactors With Slave Panels Standard Unit Includes All Features Of Relay Based Controller Plus Integrated Pattern Switching Clock. Flexible Architecture Permits Future Expansion and Logic Modification. Hardware Expansion and Logic/Software Modification Requires Service by Kintronic Labs or Purchase of PC Based Software to Program Unit.
DAC-MOD-2-12-X
24"D 24"D 24"D 24"D
Weatherproof 19" Electronic Equipment Rack For Outdoor Installation. The Above Standard Sizes Are Available. Optional Sizes Are Available Upon Request. Standard Features Include Dual AC Receptacle, Thermostatically Controlled Muffin Fan, Light With Switch and Guard.
DAC-MOD-2-12
DAC-MOD-2-12-C
x x x x
MODEL MRH-1-24DW
19" Rack/Two Power Levels/Remote 19" Rack/Two Power Levels/Local and
FOR DIRECTIONAL SYSTEMS STOCK #
STOCK #
DESCRIPTION
SER-1-72
Standard Equipment Rack (Height: 72") Rack Space 67" Standard Equipment Rack (Height 78") Rack Space 73"
SER-1-78
Standard Features Include Thermostatically Controlled Fan Installed In Top, AC Power Strip and Rear Hinged Door.
DOOR OPTIONS
Option to Add Remote Current Monitoring Capability For Up To Eight Delta Current Meters Option to Add Ability To Control An Additional 8 Contactors To PLC Standard Controller
Prices for modem and other options or custom requirements are available upon request.RELAY BASED DIRECTIONAL SYSTEM CONTROLLERS ARE PRICED ON A CUSTOM BASIS.
STOCK #
SER-LD-72 Hinged Lexan Front Door For 72" Rack SER-LD-78 Hinged Lexan Front Door For 78" Rack STANDARD EQUIPMENT RACK
Other Heights and Options Are Available Upon Request
STATIC DRAIN CHOKE WITH CORONA RING
WEATHERPROOF HOUSING STOCK #`
TOWER LIGHTING CHOKES
LC-2-12 LC-2-10 LC-2-8 LC-3-12 LC-3-10 LC-3-8 LC-3-12HV LC-3-10HV LC-4-12 LC-4-10 LC-IH LC-H
Two Wire (#12), 15 Amp Current Rating Two Wire (#10), 25 Amp Current Rating Two Wire (#8), 35 Amp Current Rating Three Wire (#12), 15 Amp Current Rating Three Wire (#10), 25 Amp Current Rating Three Wire (#8), 35 Amp Current Rating Three Wire (#12) High Voltage Lighting Choke 15A/20KV Three Wire (#10) High Voltage Lighting Choke 25A/20KV Four Wire (#12), 15 Amp Current Rating Four Wire (#10), 25 Amp Current Rating Lighting Choke Installation In Housing Weatherproof Housing Only 12"W x 12"D x 24"H
STOCK #
STATIC DRAIN CHOKES
SDC-1F SDC-CR SDC-1FS/CR
Fiberglass Form, Frequency Range 500-1700 KHZ Corona Ring Fiberglass Form, High Current With Corona Ring Frequency Range 500-1700 KHZ
FEED-THRU BOWL INSULATOR ASSEMBLIES STOCK #
FIXED INDUCTORS
VARIABLE INDUCTORS
STRAP AND TUBING
INDUCTOR CLIPS
TRANSMITTING CAPACITORS TYPE 291 MICA CAPACITORS
DESCRIPTION
Insulator Bowl High Power 9-1/2" O.D. x 8-1/2" I.D. 2-1/8" Hole IBCG-5003 Insulator Bowl Cork Gasket for I2698 IB-HS-20-158 Insulator Bowl (I2698) Hollow Pipe 20"L x 1-5/8" O.D. x 1-1/2" I.D. With Hardware and Adaptor Plate ISO3460B Insulator Bowl High Voltage 7" O.D. x 6-1/2" I.D. 1-5/8" Hole IBAR-3460B Insulator Bowl Aluminum Ring With Holes for I3460B IBCG-3460B Insulator Bowl Cork Gasket IBBR-3460B Insulator Bowl Bakelite Ring With Holes IB-HS-14-118 Insulator Bowl Hollow Pipe 14"L x 1-1/8" O.D. x 1" I.D. IBCR-3460B Insulator Bowl Corona Ring For 3460B ISO 804005 (BI-1)(2701) Insulator Bowl 7" O.D. x 5-1/2" I.D. 1/2" Hole ISO 8040075 Insulator Bowl 7" O.D. x 5-1/2" I.D. 3/4" Hole ISO 804010 Insulator Bowl 7" O.D. x 5-1/2" I.D. 1" Hole IBCG-2701 Insulator Bowl Cork Gasket for 2701 IBAR-2701 Insulator Bowl Aluminum Ring With Holes For 2701 IBCR-2701 Insulator Bowl Corona Ring For 2701 IBPR-2701 Insulator Bowl Bakelite Ring For 2701 ISO 306 (BI-2) Insulator Bowl 5-5/8" O.D. x 3-1/8" I.D. 9/ 16" Hole With 6 9-32 Mounting Holes ISO 306A Insulator Bowl 4-3/4" O.D. x 3-1/4" I.D. 9/16 “ Hole IBCG-306 Insulator Bowl Cork Gasket For 306 IBAR-306A Insulator Bowl Aluminum Ring With Holes for 306A IBAP-SS Insulator Bowl Adaptor Plate For RF Connection to Solid Stud IB-SS-09-12WHD Insulator Bowl Solid Stud 9"L x 1/2" O.D. With Hardware IB-HS-09-12WHD Insulator Bowl Hollow Stud 9"L x 1/2" O.D. With Hardware ISO 306 + Accessories IB-SS-11-12WHD Insulator Bowl Solid Stud 11"L x 1/2"O.D. With Hardware IB-HS-11-12WHD Insulator Bowl Hollow Stud 11"L x 1/2" O.D. With Hardware IB-SS-16-12WHD Insulator Bowl Solid Stud 16"L x 1/2" O.D. With Hardware IB-HS-16-12WHD Insulator Bowl Hollow Stud ISO 804005 + Accessories 16"L x 1/2" O.D. With Hardware IB-SS-20-12WHD Insulator Bowl Solid Stud 20"L x 1/2" O.D. With Hardware IB-HS-20-12WHD Insulator Bowl Hollow Stud 20"L x 1/2" O.D. With Hardware IB-SS-11-34WHD Insulator Bowl Solid Stud 11" x ISO 3460B + Accessories 3/4" O.D. With Hardware IB-HS-11-34WHD Insulator Bowl Hollow Stud 11"L x 3/4" O.D. With Hardware ISO503 Insulator Double Bowl Assembly, 1-3/4" Bowls IBDP-06-14 Insulator Bowl Dielectric Panel ISO 5003 6"W x 6"H x 1/4"T IBDP-12-14 Insulator Bowl Dielectric Panel 12"W x 12"H x 1/4"T IBDP-24-14 Insulator Bowl Dielectric Panel 24"W x 24"H x 1/4"T IBDP-12-12 Insulator Bowl Dielectric Panel 12W” x 12H” x 1/2"T IBDP-24-12 Insulator Bowl Dielectric Panel 24"W x 24"H x 1/2"T
NOTE: First number represents inductance in microphenries and the second number represents current in amperes.
J-PLUGS AND PLUG-IN METER HANDLES
R.F. CONTACTORS & PARTS
RIGHT: 10, 15, 20 AMP FIXED RIBBON TYPE
SILVERPLATED COPPER TUBING
20A VARIABLE
ABOVE: 7 AMP FIXED RIBBON TYPE
LEFT: 30, 40, 50, 60, 80, 100, 150, 200 AMP FIXED TUBING TYPE
7A HI-Q FIXED
10A HI-Q FIXED
15A HI-Q FIXED
20A HI-Q FIXED
30A HI-Q FIXED
40A HI-Q FIXED
L11-7 L19-7 L26-7 L33-7 L40-7 L47-7 L61-7 L74-7
L5-10 L10-10 L15-10 L20-10 L27-10 L32-10 L37-10 L40-10 L45-10 L60-10 L65-10 L70-10 L85-10 L100-10 L110-10 L120-10 L148-10
L5-15 L10-15 L15-15 L20-15 L26-15 L35-15 L40-15 L45-15 L50-15 L60-15 L70-15 L80-15 L95-15 L100-15 L110-15 L120-15 L145-15
L5-20 L10-20 L15-20 L20-20 L26-20 L35-20 L40-20 L50-20 L60-20 L70-20 L80-20 L98-20 L110-20 L120-20 L150-20
L6-30 L10-30 L15-30 L20-30 L26-30 L30-30 L35-30 L42-30 L45-30 L50-30 L55-30 L65-30 L72-30 L92-30 L108-30 L130-30
L5-40 L7-40 L9-40 L10-40 L12-40 L15-40 L18-40 L20-40 L25-40 L30-40 L40-40 L50-40 L58-40 L65-40 L86-40 L94-40
50A HI-Q FIXED
60A HI-Q FIXED
80A HI-Q FIXED
100A HI-Q FIXED
150A HI-Q FIXED
200A HI-Q FIXED
L5-50 L10-50 L15-50 L20-50 L25-50 L35-50 L48-50 L60-50 L78-50
L5-60 L8-60 L12-60 L15-60 L22-60 L30-60 L40-60 L51-60 L66-60 L76-60 L91-60
L6-80 L10-80 L15-80 L20-80 L25-80 L30-80 L48-80 L65-80 L74-80 L85-80 L100-80
L6-100 L10-100 L15-100 L20-100 L25-100 L30-100 L40-100 L48-100 L65-100 L74-100 L85-100 L100-100
L6-150 L10-150 L14-150 L19-150 L24-150 L29-150 L34-150 L40-150 L52-150 L65-150 L78-150 L98-150
L4-200 L9-200 L15-200 L21-200 L28-200 L35-200 L43-200 L51-200 L59-200 L68-200 L76-200 L85-200 L93-200 L102-200
30A/40A VARIABLE
20A HI-Q VARIABLE
30A HI-Q VARIABLE
40A HI-Q VARIABLE
50A HI-Q VARIABLE
60A HI-Q VARIABLE
80A HI-Q VARIABLE
LV5-20 LV10-20 LV16-20 LV20-20 LV25-20 LV35-20 LV40-20 LV50-20 LV60-20 LV70-20 LV80-20 LV90-20 LV100-20 LV105-20 LV110-20 LV120-20
LV5-30 LV8-30 LV10-30 LV15-30 LV17-30 LV21-30 LV28-30 LV35-30 LV48-30 LV63-30 LV70-30 LV80-30 LV90-30 LV125-30
LV5-40 LV7-40 LV9-40 LV14-40 LV19-40 LV24-40 LV32-40 LV40-40 LV50-40 LV56-40 LV70-40
LV5-50 LV10-50 LV15-50 LV20-50 LV25-50 LV35-50 LV48-50 LV60-50 LV73-50
LV5-60 LV8-60 LV12-60 LV15-60 LV22-60 LV30-60 LV40-60 LV51-60 LV66-60 LV76-60 LV91-60
LV6-80 LV10-80 LV15-80 LV20-80 LV25-80 LV30-80 LV48-80
LEFT: J-PLUG AND METER PLUG OPTIONS
ABOVE:RFC-40-20
ABOVE: RFC-100-35 RIGHT: METER PLUG FOR SAMPLED METER SYSTEM
JP-J1 JP-J1HV JP-J2 JP-J2HV JP-BD1 JP-SB1 JP-SB2 JP-SB3 JP-MP1
J-Plug Two Terminal Jack (30 AMP) J-Plug Two Terminal Jack (60 AMP) J-Plug Three Terminal Jack J-Plug Three Terminal Jack High Voltage Boltdown Two Terminal Shorting Jack (100 Amp) J-Plug Shorting Bar (Handle 3"W x 4"H) J-Plug Shorting Bar (Handle 3"W x 7"H) J-Plug Shorting Bar (Handle 4"W x 6"H) Plug-In Meter Handle (Internal Thermocouple Meters) Plug-In Meter Handle (External Thermocouple Meters) Delta Meter Handle For Use With JP-J1HV
JP-MP2 JP-MPD
CABLE TERMINATING CLAMPS
RFC-200-30
Stock # RFC-40-20-1-115 RFC-40-20-1-230 RFC-40-20-2-115 RFC-40-20-2-230 RFC-80-30-1-110 RFC-80-30-1-220 RFC-80-30-2-110 RFC-80-30-2-220 RFC-100-35-110-1 RFC-100-35-220-1 RFC-100-35-110-2 RFC-100-35-220-2 RFC-150-55-1-240 RFC-150-55-2-240 RFC-200-30-1-220 RFC-200-30-2-220 RFC-200-100-1S RFC-200-100-1 RFC-02P
STOCK #
DESCRIPTION
CC-12 CC-17 CC-78 CC-114 CC-158 CC-214 CBGC-38 CBGC-12 CBGC-114 CBGC-158
1/2" Cable Clamp RG-17 or RG-19 Cable Clamp 7/8" Cable Clamp 1-1/4" Cable Clamp 1-5/8" Cable Clamp 2-1/4" Cable Clamp Box Grounding Clamp 3/8" Box Grounding Clamp 1/2" Box Grounding Clamp 1-1/4" Box Grounding Clamp 1-5/8"
RFC-50 RFC-61 RFC-80 RFC-03P RFC-03LP RFC-75P RFC-19 RFC-19-L RFC-52 RFC-82 RFC-20 RFC-20-L
RFC-200-100
DESCRIPTION R.F. Contactor, 40A, 20 KV, SPDT (115 VAC) R.F. Contactor, 40A, 20 KV, SPDT (230 VAC) R.F. Contactor, 40 A, 20 KV, DPDT (115 VAC) R.F. Contactor, 40 A, 20 KV, DPDT (230 VAC) R.F. Contactor, 80 A, 30 KV, SPDT (110 VAC) R.F. Contactor, 80 A, 30 KV, SPDT (220 VAC) R.F. Contactor, 80 A, 30 KV, DPDT (110 VAC) R.F. Contactor, 80 A, 30 KV, DPDT (220 VAC) R.F. Contactor, 100 A, 35 KV, SPDT (110 VAC) R.F. Contactor, 100 A, 35 KV, SPDT (220 VAC) R.F. Contactor, 100 A, 35 KV, DPDT (110 VAC) R.F. Contactor, 100 A, 35 KV, DPDT (220 VAC) R.F. Contactor, 150 A, 55 KV, SPST (240 VAC) R.F. Contactor, 150 A, 55 KV, DPST (240 VAC) R.F. Contactor, 200 A, 30 KV, SPDT (220 VAC) R.F. Contactor, 200 A, 30 KV, DPDT (220 VAC) R.F. Motorized Switch, Single Pole Single Throw, 200A/100KV R.F. Motorized Switch, Single Pole Double Throw, 200A/100KV Finger Contact Holder For RFC40-20 and RFC80-30 Finger Contact Holder For RFC-100-35 Finger Contact Holder For RFC-150-55 Finger Contact Holder For RFC-200-30 Spring Finger Contact For RFC-40/RFC-100 Spring Finger Contact For RFC-80 Sprint Finger Contact for RFC-15 Stationary Insulator Bar For RFC-40-20 Stationary Insulator Bar For RFC-80-30 Side Insulator Bar For RFC-100-35 Side Insulator Bar For RFC-200-30 Movable Insulator Bar For RFC-40-20 Movable Insulator Bar For RFC-80-30
SILVERPLATED COPPER STRAP STOCK #
COPPER COPPER COPPER COPPER COPPER COPPER
DESCRIPTION
34200500P 34200625P 34200750P 34201000P 34201250P 34201500P
1/2" Silver-plated Copper Strap 5/8" Silver-plated Copper Strap 3/4" Silver-plated Copper Strap 1" Silver-plated Copper Strap 1-1/4" Silver-plated Copper Strap 1-1/2" Silver-plated Copper Strap
COPPER TUBING
40A/50A/60A VARIABLE 80A/100A VARIABLE
RADIAL ARM INDUCTORS
STOCK # COPPER 36103315P
DESCRIPTION 5/16" OD x .032" Silver-plated Copper Tubing (25 Amp) (.109 lb/ft)
COPPER 36103877P
3/8" OD x .032" Silver-plated Copper Tubing (30 Amp) (.134 lb/ft) 1/2" OD x .032" Silver-plated Copper Tubing (40 Amp) (.182 lb/ft) 5/8" OD x .035" Silver-plated Copper Tubing (50 Amp) (.252 lb/ft) 3/4" OD x .035 Silver Plated Copper Tubing (60 Amp) (.306 lb/ft) 7/8" OD x .045 Silver Plated Copper Tubing (80 Amp) (.456 lb/ft) 1-1/8" OD x .050 Silver Plated Copper Tubing (100 Amp) (.656 lb/ft) 1-3/8" OD x .055 Silver Plated Copper Tubing (150 Amp) (.884 lb/ft)
COPPER 36107811P COPPER 36108371P
80A HI-Q RADIAL
100A HI-Q RADIAL
150A HI-Q RADIAL
200A HI-Q RADIAL
L6-80-RA L10-80-RA L15-80-RA L20-80-RA L25-80-RA L30-80-RA L48-80-RA L65-80-RA L74-80-RA L85-80-RA L100-80-RA
L6-100-RA L10-100-RA L15-100-RA L20-100-RA L25-100-RA L30-100-RA L40-100-RA L48-100-RA L65-100-RA L74-100-RA L85-100-RA L100-100-RA
L6-150-RA L10-150-RA L14-150-RA L19-150-RA L24-150-RA L29-150-RA L34-150-RA L40-150-RA L52-150-RA L65-150-RA L78-150-RA L98-150-RA
L4-200-RA L9-200-RA L15-200-RA L21-200-RA L28-200-RA L35-200-RA L43-200-RA L51-200-RA L59-200-RA L68-200-RA L76-200-RA L85-200-RA L93-200-RA L102-200-RA
COPPER 36108934P COPPER 36109007P
COPPER GROUND STRAP STOCK #
DESCRIPTION
COPPER 34301000
1" x .020" Copper Ground Strap (8 ft./lb.) (.078 lb/ft) 2" x .022" Copper Ground Strap (4 ft./lb.) (.155 lb/ft) 3" x .032 Copper Ground Strap (3 ft./lb.) (.372 lb/ft) 4" x .032" Copper Ground Strap (2 ft./lb.) (.497 lb/ft) 4" x .025" Copper Ground Strap (3 ft./lb.) (.3866 lb/ft)
COPPER 34202000 COPPER 34303000 COPPER 34304000 COPPER 34254000
L19-150-RA RADIAL ARM INDUCTOR
DI 7612-S DI 3501-M-1 RFC-26 RFC-35 RFC-37 RFC-38 RFC-39 RFC-40 RFC-45-115 RFC-45-230 RFC-40-20-CK RFC-80-30-CK RFC-100-35-CK RFC-150-55-CK RFC-200-30-CK
Center Insulator Bar For RFC-100-35 Center Insulator Bar For RFC-200-30 Solenoid For RFC-40-20 (115 VAC) Solenoid For RFC-40-20 (230 VAC) Solenoid For RFC-80-30 or RFC-100-35 (110 VAC) Solenoid For RFC-80-30 or RFC-100-35 (220 VAC) Solenoid For RFC-200-30 (115 VAC) Solenoid For RFC-150-55 (240 VAC) Rubber Mounting Grommet T-Bar Contact (RFC-40-20 or RFC-80-30) #1 Microswitch Assembly #2 Microswitch Assembly #3 Microswitch Assembly #4 Microswitch Assembly Wiring Harness Wiring Harness DPDT Conversion Kit For RFC-40-20-1 DPDT Conversion Kit For RFC-80-30-1 DPDT Conversion Kit For RFC-100-35-1 DPST Conversion Kit For RFC-150-55-1 DPDT Conversion Kit For RFC-200-30-1
RF AMMETERS WESCHLER RT-351, 0-5 AMP SQUARE LAW SCALE RF AMMETER
STOCK #
DESCRIPTION
WI WI WI WI WI WI WI WI WI WI
Weschler Weschler Weschler Weschler Weschler Weschler Weschler Weschler Weschler
409C549A09 409C549A10 409C549A11 409C549A12 409C549A13 409C549A14 409C549A15 409C549A16 409C549A17 409C549A38/ 878651
WI 409C549A38/ 878654 WI 409C549A21
OTHER PARTS AVAILABLE UPON REQUEST
VACUUM CAPACITOR END PLATES
WI 409C549A22 WI 409C549A23 WI 409C549A24 WI 409C549A25 WI 409C549A26 WI 409C549A27 WI 409C549A28 WI 409C549A29
STOCK #
DESCRIPTION
CEP-3.5
END PLATE SPECIFY CAPACITOR FOR MOUNTING END PLATE SPECIFY CAPACITOR FOR MOUNTING END PLATE SPECIFY CAPACITOR FOR MOUNTING END PLATE SPECIFY CAPACITOR FOR MOUNTING CAPACITOR MOUNTING ASSEMBLY Plate For Mounting 293/294 Capacitors On Insulators
CEP-6 CEP-7 CMA-CKTVCNCLF1 CMP-293/294
DESCRIPTION
L-10 CLIP L-15 CLIP L-20 CLIP L-25 CLIP L-30 CLIP L-40 CLIP L-50 CLIP L-60 CLIP L-80 CLIP L-100 CLIP L-150 CLIP L-200 CLIP
Inductor Inductor Inductor Inductor Inductor Inductor Inductor Inductor Inductor Inductor Inductor Inductor
Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip Clip
for for for for for for for for for for for for
10 Amp or .054" Thick Ribbon 15 Amp or .072" Thick Ribbon 20 Amp or .090" Thick Ribbon 25 Amp or .25" Thick Ribbon 30 Amp or 3/8" Tubing 40 Amp or 1/2" Tubing 50 Amp or 5/8" Tubing 60 Amp or 3/4" Tubing 80 Amp or 7/8" Tubing 100 Amp or 1-1/8" Tubing 150 Amp or 1-3/8" Tubing 200 Amp or 1-5/8" Tubing
STANDOFF INSULATORS STOCK #
DESCRIPTION
ISO 348L1 ISO 348L1-1/2 ISO 348L2 ISO 348L2-1/2 ISO 348L3 ISO 348L4 ISO 348L5 ISO 348L6 ISO 3322L2 ISO 3322L3 ISO 3322L4 ISO 3322L5 ISO 3322L6 ISO 3322L7 ISO 3322L8 ISO 325L9 ISO 3336L12 ISO 415L12 ISO 415L14 ISO 415L16 IMEC-1P IMEC-2P IME-N-1 IME-N-2 IMEC-2CR IMEC-3.5CR
1" Diameter x 1" Long 1" Diameter x 1-1/2" Long 1" Diameter x 2" Long 1" Diameter x 2-1/2" Long 1" Diameter x 3" Long 1" Diameter x 4" Long 1" Diameter x 5" Long 1" Diameter x 6" Long 1-1/4" Diameter x 2" Long 1-1/4" Diameter x 3" Long 1-1/4" Diameter x 4" Long 1-1/4" Diameter x 5" Long 1-1/4" Diameter x 6" Long 1-1/4" Diameter x 7" Long 1-1/4" Diameter x 8" Long 1-1/4" Diameter x 9" Long 1" Diameter x 12" Long With Metal End Caps 1-3/4" Diameter x 12" Long With Metal End Caps 1-3/4" Diameter x 14" Long With Metal End Caps 1-3/4" Diameter x 16" Long With Metal End Caps Aluminum End Cap For 1" Insulator Aluminum End Cap For 1-1/4" Insulator IMEC-1 or IMEC-2 Installed On Insulator (One End) IMEC-1 or IMEC-2 Installed On Insulator (Both Ends) Corona Ring for 1-1/4" Insulator Corona Ring for 1-3/4" Insulator
COMPLETE HF/SHORTWAVE ANTENNA SYSTEMS & ACCESSORIES
STOCK #
DESCRIPTION
CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM
.0001 .00015 .0002 .00024 .00025 .0003 .0004 .0005 .0006 .00062 .00075 .0008 .00082 .001 .0015 .002 .0024 .003 .004 .005 .01 .015 .02 .024 .03 .1
29160B101J02 29160B151J02 29160B201J02 29160B241J02 29160B251J02 29160B301J02 29160B401J02 29160B501J02 29160B601J02 29160B621J02 29160B751J02 29160B801J02 29160B821J02 29160B102J02 29160B152J02 29160B202J02 29160B242J02 29160B302J02 29160B402J02 29160B502J02 29140B103J02 29130B153J02 29120B203J02 29120B243J02 29115B303J02 29110B104J02
0-1 Amp Square Law Scale 0-1.5 Amp Square Law Scale 0-2 Amp Square Law Scale 0-3 Amp Square Law Scale 0-5 Amp Square Law Scale 0-8 Amp Square Law Scale 0-10 Amp Square Law Scale 0-15 Amp Square Law Scale 0-20 Amp Square Law Scale
Weschler RT-351, Meter 0-30 RFA Square Law Scale with 30 RFA External Thermocouple Weschler RT-351, Meter 0-50 RFA Square Law Scale with 50 RFA External Thermocouple Weschler RT-351, 0-1 Amp Linear Expanded Scale Meter Weschler RT-351, 0-1.5 Amp Linear Expanded Scale Meter Weschler RT-351, 0-2 Amp Linear Expanded Scale Meter Weschler RT-351, 0-3 Amp Linear Expanded Scale Meter Weschler RT-351, 0-5 Amp Linear Expanded Scale Meter Weschler RT-351, 0-8 Amp Linear Expanded Scale Meter Weschler RT-351, 0-10 Amp Linear Expanded Scale Meter Weschler RT-351, 0-15 Amp Linear Expanded Scale Meter Weschler RT-351, 0-20 Amp Linear
Kintronic Labs is now manufacturing custom HF/shortwave broadcast antennas. The capabilities available to the broadcast community include: • Selection of the antenna design tailored to direct the transmitted signal to a specific target area of the world with optimum efficiency. • Complete facilities for fabrication, erection and testing of the antenna system. Types of antenna systems offered are: A. Dipole curtain arrays • Model 22-100: 2x2 dipole array rated for 100 KW • Model 44-100: 4x4 dipole array rated for 100 KW B. Rhombic C. Lazy H D. Dipole arrays for “umbrella-type” close proximity coverage
ACCESSORIES • • • •
Open wire transmission line Transmission line manual or motor-driven switches RF feedthrough panels Single band and multi-band antenna baluns
2.0 AMPS 2.4 AMPS 3.0 AMPS 3.0 AMPS 3.6 AMPS 3.9 AMPS 4.5 AMPS 5.1 AMPS 6.2 AMPS 6.2 AMPS 6.8 AMPS 6.8 AMPS 6.8 AMPS 7.5 AMPS 9.1 AMPS 11.0 AMPS 12.0 AMPS 13.0 AMPS 15.0 AMPS 16.0 AMPS 20.0 AMPS 20.0 AMPS 22.0 AMPS 22.0 AMPS 22.0 AMPS 22.0 AMPS
6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 6 KV 4 KV 3 KV 2 KV 2 KV 1.5 KV 1 KV
3.0 AMPS 3.6 AMPS 4.3 AMPS 5.1 AMPS 5.6 AMPS 6.2 AMPS 6.8 AMPS 7.5 AMPS 8.2 AMPS 8.2 AMPS 8.2 AMPS 9.1 AMPS 9.1 AMPS 10.0 AMPS 11.0 AMPS 12.0 AMPS 13.0 AMPS 15.0 AMPS 16.0 AMPS 18.0 AMPS 20.0 AMPS 22.0 AMPS
10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 10 KV 8 KV 8 KV 8 KV 6 KV 5 KV
TYPE 292 MICA CAPACITORS STOCK #
DESCRIPTION
CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM
.0001 .00015 .0002 .00025 .0003 .00039 .0005 .00056 .0006 .00062 .00075 .0008 .00082 .001 .0013 .0015 .002 .0024 .003 .004 .005 .0068
292100B101J02 292100B151J02 292100B201J02 292100B251J02 292100B301J02 292100B391J02 292100B501J02 292100B561J02 292100B601J02 292100B621J02 292100B751J02 292100B801J02 292100B821J02 292100B102J02 292100B132J02 292100B152J02 292100B202J02 29280B242J02 29280B302J02 29280B402J02 29260B502J02 29250B682J02
MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD
HOLES
DESCRIPTION
PS-1 PS-2 PS-3
1 KW Maximum Input Power With 1 Output Level 1 KW Maximum Input Power With 2 Output Level 1 KW Maximum Input Power With 3 Output Level
.01 .016 .02 .024 .051 .1
MFD MFD MFD MFD MFD MFD
24.0 27.0 30.0 33.0 36.0 39.0
AMPS AMPS AMPS AMPS AMPS AMPS
5 KV 4 KV 3 KV 3 KV 2 KV 1.5 KV
3.6 AMPS 4.7 AMPS 6.8 AMPS 9.1 AMPS 11.0 AMPS 11.0 AMPS 12.0 AMPS 12.0 AMPS 13.0 AMPS 16.0 AMPS 20.0 AMPS 22.0 AMPS 24.0 AMPS 27.0 AMPS 30.0 AMPS 30.0 AMPS 33.0 AMPS 36.0 AMPS 39.0 AMPS 43.0 AMPS 47.0 AMPS 51.0 AMPS 51.0 AMPS
20 KV 20 KV 20 KV 20 KV 20 KV 20 KV 20 KV 20 KV 20 KV 15 KV 15 KV 12 KV 12 KV 12 KV 10 KV 10 KV 10 KV 10 KV 8 KV 5 KV 5 KV 3 KV 2 KV
6.2 AMPS 9.1 AMPS 11.0 AMPS 12.0 AMPS 13.0 AMPS 15.0 AMPS 15.0 AMPS 16.0 AMPS 20.0 AMPS
30 30 30 30 30 30 30 30 25
TYPE 293 MICA CAPACITORS STOCK #
DESCRIPTION
CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM
.0001 .00015 .0003 .0005 .0006 .00068 .00075 .00082 .001 .0015 .002 .0024 .003 .004 .005 .0051 .006 .0082 .01 .015 .02 .03 .1
293200B101J02 293200B151J02 293200B301J02 293200B501J02 293200B601J02 293200B681J02 293200B751J02 293200B821J02 293200B102J02 293150B152J02 293150B202J02 293120B242J02 293120B302J02 293120B402J02 293100B502J02 293100B512J02 293100B602J02 293100B822J02 29380B103J02 29350B153J02 29350B203J02 29330B303J02 29320B104J02
MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD
TYPE 294 MICA CAPACITORS STOCK #
DESCRIPTION
CDM CDM CDM CDM CDM CDM CDM CDM CDM
.00015 .0003 .00039 .0005 .00068 .00075 .00082 .001 .0015
294300B151J02 294300B301J02 294300B391J02 294300B501J02 294300B681J02 294300B751J02 294300B821J02 294300B102J02 294250B152J02
MFD MFD MFD MFD MFD MFD MFD MFD MFD
KV KV KV KV KV KV KV KV KV
294200B202J02 294200B242J02 294200B302J02 294200B402J02 294150B502J02 294150B752J02 294120B822J02 294100B103J02 29480B153J02 29460B203J02 29460B243J02 29450B403J02 29450B473J02‘ 29430B104J02
.002 .0024 .003 .004 .005 .0075 .0082 .01 .015 .02 .024 .04 .047 .1
MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD
22.0 24.0 27.0 30.0 33.0 36.0 39.0 43.0 47.0 51.0 56.0 56.0 56.0 62.0
AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS AMPS
20 KV 20 KV 20 KV 20 KV 15 KV 15 KV 12 KV 10 KV 8 KV 6 KV 6 KV 6 KV 5 KV 3 KV
INSULATED SHAFT COUPLINGS, KNOBS, COUNTER DIALS, RIGHT ANGLE DRIVE
INSULATED COUPLINGS (CERAMIC, TEFLON)
STOCK # CC 104-251-3 CC 104-251-1 CC 104-251-2 ISC-1412 ISC-1212 ISC-1438 ISC-3838 ISC-1414 ISC-12HV STOCK # IK-12 IK-38 REID DK-1 REID DK-2 STOCK # CD-2 CD-3 CD-3L CDK-2-AL STOCK # RAD-1
INSULATED KNOBS
FAR LEFT: COUNTER DIAL LEFT: RIGHT ANGLE DRIVE
INSULATED SHAFT COUPLINGS 1/4" to 3/8" Ceramic (Voltage Rating 14 KV) 3/8" to 3/8" Ceramic 1/4" to 1/4" Ceramic 1/4" to 1/2" Teflon (Voltage Rating 20 KV) 1/2" to 1/2" Teflon 1/4" to 3/8" Teflon 3/8" to 3/8" Teflon 1/4" to 1/4" Teflon Teflon EXHV INSULATED KNOBS Variable Capacitor Knob 1/2'” Hole, Clear Polystyrene Variable Inductor Knob 3/8" Hole, Clear Polystyrene Variable Inductor Knob 3/8" Hole, Black Plastic Variable Capacitor Knob 1/2" Hole, Black Plastic COUNTER DIAL Counter Dial With Knurled Aluminum Knob Counter Dial Oversized With Knurled Aluminum Knob Locking Counter Dial with Oversized Knob Knurled Aluminum Knob RIGHT ANGLE DRIVE Ball Bearing Right Angle Drive 2:1 Ratio
continues...
Stainless Steel Screw, 1/4-20 x 1-1/8" Pan Head Stainless Steel Screw, 1/4-20 x 1" Phillips Pan Head Stainless Steel Screw, 1/4-20 x 7/8" Pan Head Stainless Steel Screw, 1/4-20 x 3/4" Pan Head Stainless Steel Screw, 1/4-20 x 5/8" Pan Head Stainless Steel Screw, 1/4-20 x 1/2" Pan Head Stainless Steel Screw, 1/4-20 x 3/8" Pan Head Brass Stud, 1/4-20 x 1" Brass Stud, 1/4-20 x 1-1/8" Stainless Steel Stud, 1/4-20 x 1-3/4" Stainless Steel Stud, 1/4-20 x 1-1/2" Stainless Steel Stud, 1/4-20 x 1-1/4" Stainless Steel Stud, 1/4-20 x 1-3/8" Stainless Steel Hex Acorn Nut, 1/4-20 Stainless Steel Hex Thin Nut, 1/4-20 Lock Washer, Silicone Bronze 1/4" Nickel Plated Brass Flat Washer, 1/4" Nickel Plated Black Fiber Washer, 1" O.D. x 1/4" I.D. x 1/16" Thick Black Fiber Washer, 1-1/4" O.D. x 1/4" I.D. x 1/16" Thick Above sold in 100 pc bags. KTL AFW-1 Aluminum Flat Washer 1" Dia x 1/8" Thick x 1/4-20 Thread KTL AFW-2 Aluminum Flat Washer 1-1/4" Dia x 1/8" Thick x 1/4-20 Thread
CUSTOM DETUNING UNITS
QUASI-COAXIAL TRANSMISSION LINE FOR HIGH POWER AM/MW APPLICATIONS
TECHNICAL FEATURES • Less than one third electrical height of quarter wave mast on the same frequency. • Requires five vertical supports that may be wooden utility poles or guyed, lattice masts depending on the frequency of operation. • Requires 120-radial quarter wave ground system. • Radiating efficiency of 98% compared to quarter wave mast. • Vertical pattern is predictable. • Input bandwidth compatible with High Definition (HD) and Digital Radio Mondiale (DRM) digital audio broadcast transmitters.
CUSTOM FOLDED MONOPOLE KITS WHY USE A FOLDED MONOPOLE? • To eliminate the need for a static drain choke or lighting transformer on an AM tower • To permit AM operation on a grounded tower so that FM, STL, Paging, Cellular, PCS or other antennas may be installed on the tower without isolation transformers • To raise the drive impedance of an electrical short AM/MW antenna
FEATURES:
SINGLE BAND ANTENNA BALUN
STOCK #
DESCRIPTION
29250B103J02 29240B163J02 29230B203J02 29230B243J02 29220B513J02 29215B104J02
CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM CDM
DESCRIPTION
HDWR 91772A543 HDWR 91772A542 HDWR 91772A541 HDWR 91772A540 HDWR 91772A539 HDWR 91772A537 HDWR 91772A535 HDWR 93025A542 HDWR 93025A543 HDWR 95412A548 HDWR 95412A546 HDWR 95412A544 HDWR 95412A545 HDWR 91855A350 HDWR 91847A029 HDWR 92165A029 HDWR 92916A365 HDWR 96100A101 HDWR 96100A189
HOLES
MODEL PS-3
STOCK #
CDM CDM CDM CDM CDM CDM
KINSTAR AM/MW LOW PROFILE ANTENNA TECHNOLOGY
HARDWARE
HOLES
HOLES
LEFT TO RIGHT: TYPE 291, 292, 293, 294 MICA CAPACITORS
continues...
STOCK #
RT-351, RT-351, RT-351, RT-351, RT-351, RT-351, RT-351, RT-351, RT-351,
MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD MFD
PRE-SUNRISE OR POST-SUNRISE POWER CUTBACK UNITS
STOCK # CMA-CKTVCNCLF1
CEP-5
STOCK #
(Above sold only in 25 Ft Rolls)
COPPER 36106680P
RFC-53 RFC-83 RFC-25-40-115 RFC-25-40-230 RFC-25-80100-110
ABOVE: RFC-80-30
COPPER GROUND STRAP
COPPER 36105567P
RFC-25-80100-220
DESCRIPTION
continued...
WITH TWO MOUNTING FLANGES
ISO 5003
STOCK #
continued...
MULTI-BAND ANTENNA BALUN OPEN WIRE FEEDLINE SUPPORT
OPEN WIRE FEEDLINE DEAD END
• Three Wire, Four Wire and Six Wire Kits are available. • Tailored for installation on any type of tower • Fixed Cross Section, Guyed • Self Supporting • Cellular Telephone Monopole • Wind Load Capacity • 90 MPH (no ice) Standard • Optional designs for higher wind load • Transmitter Power Rating: 1-100KW • Frequency Range: 525-1705 KHZ
CUSTOM DETUNING UNIT
Custom Detuning Units are utilized for detuning cellular, paging, microwave, etc. tower in the near vicinity of an AM radio transmitting site. Features include: • Fixed or variable inductors with silverplated finish. • Mica or vacuum capacitors. • AC or DC motor drive with limit switches for variable inductors or capacitors. • Motor drive control unit. • Ammeters installed on meter panel in base unit. • Two or three terminal J-plugs for impedance measurement, current measurement or skirt grounding purposes. • All aluminum weatherproof housing with multi-coat lacquet paint finish. • Copper strap for RF grounding. • Bowl insulator assembly for attachment to tower detuning skirt. • Complete installation documentation.
TOWER SKIRT DETUNING KITS A Tower Skirt Detuning Kit is utilized to effectively remove the effects of a tower structure on the radiated pattern of an AM/MW antenna located in close proximity to the re-radiating structure. These kits are custom-fabricated to the customer’s specifications.
KINTRONIC LABS Kintronic labs manufacturers a complete line of custom support frames, dead ends, and wall feed-through panels for quasi-coaxial transmission line.
INSTALLED DETUNE SKIRT KIT