Transcript
LANmark-OF Pigtails • • • •
Optical fiber pigtails 62.5 - 50 - 9 micron Compliant for OM1 - OM2 - OM3 - OS1 Available in 1.5m for use in splice trays Maxi-strip construction allows stripping over 1m lengths
Operating temperature, range -10 .. 50 °C
Generated 9/17/04
http://www.nexans.be/e-service
Page 1 / 3
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
Description Application Nexans LANmark-OF optical fibre pigtails have been designed for applications where a high level of optical features is required. • Suitable for use in Patch Panels using Splice Tray. • Our pigtails are very easy to strip thanks to use of Maxi-strip instead of Tight Buffer fibre. • Easy differentiation of cable type by using coloured pigtails. -Yellow for Singlemode -Blue for MM62.5 -Green for MM50 -Green with black rings for OM3 MM50 Applications support : • • • • • • • • •
FDDI 100 Mbps Ethernet 10 base FL Fast Ethernet 100 base FX Gigabit Ethernet 1000 base SX/LX 10 Gigabit Ethernet 10G base LX Fibre Channel 266 Mbps 1000 Mbps ATM 155 Mbps 622 Mbps
Performance Nexans LANmark-OF pigtails are available in all standardised optical fibre classes, multimode and singlemode. The MM62.5 version is designed for use in an OM1 compliant system, the MM50 version for OM2 systems and the MM50 OM3 for OM3 systems. The singlemode version is OS1 compliant. The multimode versions can be used in laser optmised systems using the LANmarkOF xt cables.
Guarantees Nexans LANmark-OF pigtails are guaranteed to support usual LED based applications as well as Laser based applications. They are covered by Nexans warranty as described in the General Terms and Conditions.
Technical data - Physical Temperature rating
-10/+50°C
Technical data - Optical Typical Insertion Loss Minimum Return Loss
MM50&MM62.5&OM3 0.3dB MM50&MM62.5&OM3 30dB
SM 0.25dB SM 50dB
Operating temperature, range -10 .. 50 °C
Generated 9/17/04
http://www.nexans.be/e-service
Page 2 / 3
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.
LANmark-OF Pigtails Characteristics Usage characteristics Operating temperature, range Length Component function
-10 .. 50 °C 1.5 m Pigtail
Optical characteristics Mated pair transmission performance of OF connecting hardware
Insertion loss min. Return loss max.
MM50 & MM62,5 ST&SC/PC&LC MT-RJ 0,3dB 0,3dB >40dB >35dB
SM ST&SC/PC&LC 0,2dB 45dB
MT-RJ N/A N/A
Product List Nexans ref. N890.061 N890.062 N890.071 N890.072 N890.046 N890.047 N890.039 N890.038 N890.051 N890.052 N890.037 N890.036 N890.081 N890.042 N890.041 N890.040
Name LANmark-OF Pigtail MM 50/125, LC,1,5m, LSZH LANmark-OF Pigtail MM 50/125, MTRJ,1,5m, LSZH LANmark-OF Pigtail MM 50/125, OM3, LC, 1,5m LSZH LANmark-OF Pigtail MM 50/125, OM3, MTRJ, 1,5m LSZH LANmark-OF Pigtail MM 50/125, OM3, SC/PC, 1,5m, LSZH LANmark-OF Pigtail MM 50/125, OM3, ST/PC, 1,5m, LSZH LANmark-OF Pigtail MM 50/125, SC/PC, 1,5m, LSZH LANmark-OF Pigtail MM 50/125, ST/PC, 1,5m, LSZH LANmark-OF Pigtail MM 62,5/125, LC,1,5m, LSZH LANmark-OF Pigtail MM 62,5/125, MTRJ,1,5m, LSZH LANmark-OF Pigtail MM 62,5/125, SC/PC, 1,5m, LSZH LANmark-OF Pigtail MM 62,5/125, ST/PC, 1,5m, LSZH LANmark-OF Pigtail Single Mode, LC,1,5m, LSZH LANmark-OF Pigtail Single Mode, SC/APC, 1,5m, LSZH LANmark-OF Pigtail Single Mode, SC/PC, 1,5m, LSZH LANmark-OF Pigtail Single Mode, ST/PC, 1,5m, LSZH
Generated 9/17/04
http://www.nexans.be/e-service
Insertion loss of optical connector (dB) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.35 0.2 0.2
Page 3 / 3
All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.