Transcript
System Remote MIC Station/Keypad
RM-6024/6012KP Remote MIC Extender
RME-6108
M E T S Y S 0 0 0 6
System Remote MIC Station/ 12Key MIC Station Keypad
RM-6024 RM-6012KP RM-6024 is remote microphone for activating Mic, Chime and BGM by controlling a 6000 SYSTEM from a distance. RM-6012KP is key pad expansion unit for RM-6024.
•24 ConTRol KEY - 24 different zone can be controlled with 24 control key. •KEY Pad ExPanSion - The control key can be expanded up to 48 keys with RM-6012KP. •ZonE MaCRo funCTion - Many different zone can be set as a single button to operate through PC window program. •all BuTTon - All button for selecting entire broadcasting zone.
•aux inPuT - Route for external sound source to broadcasting. •ouTPuT lEvEl lEd - Monitoring a output signal level with LED level meter. •BRoadCaSTinG STaTuS diSPlaY - It shows the remote amp status with power,communication fault and priority broadcasing. •laBEl - Label for distinguishable broadcasting area.
•MiC BRoadCaSTinG - High spec condensing mic for high quality sound announcement.
•CaT5 CaBlE - Single CAT5 line delievers both audio and data which enable to accomplish a easy installation and maintenance.
•CHiME BRoadCaSTinG - Chime notification before and after broadcasting.
•voluME ConTRol - Adjusting indivisual volume of MIC/CHIME/AUX.
FRONT/REAR PANEL
2
1
4
3
5 7
6
8
9
10
1 ALL BUTTON 2 MIC 3 OUTPUT LEVEL LED 4 POWER/FAULT/BUSY LED 5 CHIME BUTTON
6 TALK ON/OFF BUTTON 7 ZONE DISPLAY LED AND LABEL 8 ZONE SELECTION BUTTON 9 SIDE PAD EXPANSION KEYPAD (RM-6012KP)
4 1
1 DC INPUT TERMINAL 2 ADDRESS SWITCH 3 DATA & AUDIO TERMINAL (RJ-45)
2
3
5
4 MIC/AUX/CHIME VOLUME 5 AUX INPUT TERMINAL
Remote MIC Extender
RME-6108
The RME-6108 remote microphone extender adds additional microphone stations
•REMoTE MiC ExTEnSion - 8 RM-6024 can be connects to single RME-6108 - 6000 1BUS: expansion up to 16 units of RM-6024 - 6000 8BUS: expansion up to 32 units of RM-6024
•PRioRiTY SETTinG funCTion - Sets the priority for each connected RM-6024.
•STaTuS diSPlaY lEd - It shows the remote amp status such as connection/operation/communication of remote mic.
•STand-BY lEd - It shows the remote amp status such as power and communication fault
FRONT/REAR PANEL
1
1 2
1 RM(REMOTE MIC) OPERATION DISPLAY LED (1CH ~ 8CH) 2 STAND-BY LED
2 1
1 OUTPUT TERMINAL 2 INPUT TERMINAL (1CH ~ 8CH)
3
3 DC INPUT TERMINAL
System Remote MIC Station/ 12Key MIC Station Keypad
RM-6024/6012KP SPECIFICATIONS RM-6024/6012KP Channel
24CH
Communication Protocol
RS-422(Maximum 1km/3,280 feet)
Audio INPUT SENSTIVITY MIC
-60dB
THD+N
Less than 0.5%
FREQUENCY RESPONSE
120Hz ~ 20kHz
S/N
Better than 50dB
INPUT SENSTIVITY AUX
-10dB
THD+N
Less than 0.5%
FREQUENCY RESPONSE
120Hz ~ 20kHz
S/N
Better than 60dB
Operation Temperature
-10°C ~ +40°C / 14°F ~ 104°F
Power Source Weight (Set)
DC 24V RM-6024
1.2kg/2.6lb
RM-6024KP
250g/0.55Ib
Dimensions
RM-6024
456(W) x 65(H) x 200(D)mm/17.9(W)x2.5(H)x7.9(D)in
(Set)
RM-6024KP
137(W) x 54(H) x 155(D)mm/5.3(W)x2.1(H)x6.1(D)in
※ Specifications and design are subject to change without notice.
137.5 120
456
65
199
Remote MIC Extender
RME-6108 SPECIFICATIONS RME-6108 Channel
8CH
Communications Protocol Operating Temperature
RS-422 (Maximum 1km/3,280 feet) -10°C ~ +40°C / 14°F ~ 104°F
Power Source
DC 24V
Weight (Set)
2.8kg/6.17lbs
Dimensions (Set)
482(W)x44(H)x280(D)mm/19(W)x1.7(H)x11(D)in
※ Specifications and design are subject to change without notice.
37.5
tb4p-2
5
280
440
44
482
REMoTE ConTRollER
Inter-M Corp. (IMK) 653-5 Banghak-Dong, Dobong-Ku, Seoul, Korea Overseas Sales Team Tel_ +82-2-2289-8141~7 Fax_ +82-2-2289-8149
E-mail_
[email protected]
* Design and specification are subject to be changed without pre notice.
www.inter-m.com 2013. 1