Preview only show first 10 pages with watermark. For full document please download

0012_schema_web_en_20100611

   EMBED


Share

Transcript

DiV-1271 Searching Light *) Type: Sunshin HR1012-24V Searching Light *) Type: Sunshin HR1012-24V Horn *) AHD-EST AHD-DACP AHD-DEOP Wing Port Signal Ignition Ignition NAVNET 3D *) RPU-013 *) (Option) AHD-TP 2 EC-1000C *) AHD-WOP 90 START START STOP STOP Emerg. Emerg. STOP STOP 60 AHD-DEOP 5m 5m 10m 90 Ext. Signal 10m DVI-Splitter Termination resistor I gnition Ignition ST ART START STOP ST OP E m erg. Em erg. STOP STOP Wing Stbd. Start Stop DANGER AHD-CUC CAN AHD-EST A HD-DEOP 120 Start Stop DANGER AHD-EST A HD-DAP I nterv al 120 Ext. Signal AHD-DACP Signal Sec. 60 Interval (Option) AHD-TP 2 AHD-EST AH D-DEOP AHD- DAP Sec. AHD-WOP CAN DVI-Splitter 25m 25m 25m Termination resistor 25m 25m 5m AHD-1019 #1 AHD-1019 #2 AHD 1019 5m 5m AHD-919 5m AHD-1019 #3 AHD 1019 AHD-919 AHD-1019 #4 AHD 1 019 AHD 1019 A HD 1019 AHD 1 019 10m Power Power ECDIS CAN5 CAN3 CAN2 Power ECDIS Fault Video Video CAN5 CAN3 CAN2 Power ECDIS Power ECDIS Fault CAN1 Fau lt Video CAN5 CAN3 Power ECDIS ECDIS Fault CAN1 CAN2 Fault CAN1 Video CAN5 VGA CAN3 CAN2 Fau lt CAN1 Termination resistor Termination Termination Termination resistor resistor resistor 2m Bridge Desk (Option) AHD-SLP Bridge AHD-DC AHD-DRM T AHD-WOP AHD-DC AHD-DACP AHD-EST AHD-DPS 02 B21 AHD-EOP AHD- DAP A H D-DRM T Fa ult 1 Fast M enu AHD-DC AHD-EOP 2m Stbd Top 10 4 Stern 11 5 Anchor 12 6 R ed/Red Upper 13 7 R ed/Red Lower 14 (Option) AHD-TP 2 A H D-DRM T Dis play Po wer 8 Port 2 3 (Option) AHD-SLP AHD-DRM T AH D-DC AHD-DP S02 B14 Fa ult Fast Signal Slow AHD-EST AHD-EOP A HD-EOP Nav ./Signal Light Control Panel Display P ower 2m 2m START Ignition 9 START Ignition Slow Menu Device Device Int erval 60 90 Sec. Intern Extern Menu S tart S top Speed Intern E xtern M enu 120 Ext. Signal Emerg. Emerg. STOP STOP STOP STO P Speed OK OK Fault Fa ult DANGER Supply failure 2000 hours remaining Sys tem fail ure Dim. / Check Enable DISPLAY OPERATION D IS PLAY OPERATION CAN CAN CAN DPS02 Switch Switch 1 0 2 2 X 15m 2m 0 - OFF 1 - Main Power Supp ly 2 - Emergency Power Sup ply 2m 2m 2m AHD-UCC Position and Signal Lights Control AHD-DPS02 G14 AHD-UCC AHD-UCC Extension Module AHD-DPS02 A07 P ower F ault P ower F ault Po wer Fa ult Data Station AHD-SAS 15 (Sea Fire) 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Binary Data Station AHD-PS 30 10m 2m 28 29 30 31 32 33 34 35 36 37 38 39 40 41 POWER 28 29 30 31 32 33 34 35 36 37 38 39 40 41 CAN Sensor In 13 In 14 In 15 In 11 In 12 In 8 In 9 In 10 In 5 In 6 In 7 In 3 In 4 In 1 In 2 Power Fault IN30 IN29 IN28 IN27 IN26 IN25 IN24 IN23 IN22 IN21 IN20 IN19 IN18 IN16 IN17 IN15 IN14 IN13 IN12 IN11 IN10 IN9 IN8 IN7 IN6 IN5 IN4 IN3 IN2 L8 L9 L10 L11 L12 L13 L14 IN1 28, 29 30, 31 32, 33 34, 35 36, 37 38, 39 40, 41 S3 L1 L2 L3 L4 L5 L6 L7 S2 14, 15 16, 17 17, 19 20, 21 22, 23 24, 25 26, 27 AHD-DPS 02 G14 / DC24 3 5 7 10 12 14 16 2 4 V DC 9 11 13 15 Lam p voltage 24VDC CAN Device number C o n trol In put S2 Ext. Bus Output E xt. Bus In put in tern S1 Control Input C OM2 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 COM1 intern Common alarm 8 PWR fail 6 CAN Terminal FURUNO NMEA 2000 *) 42 43 44 45 46 47 48 49 50 51 52 53 Quit input - + - + SH 42 43 44 45 46 47 48 49 50 51 52 53 2 3 4 5 6 1 4 1 L a m p voltage E xt. B us Ou tput 2 U+ U- 1N 2N 3N 4N 5N 6N 7N 8N 9N 10N11N12N13N14N15N 16N17N18N19N20N21N22N23N24N25N26N27N28N29N30N Common 24 VDC ±25 % CAN - Lamp fail Powe r supply + 1 PE 2 + Main 4 Power 6 + Emergency 8 Power 3 S+ M-PWR 7 S+ E-PWR 10 S+ PWR-In S1 14 15 16 17 18 19 20 21 22 23 24 25 26 27 5 S- M-PWR 9 S- E-PWR 12 S- PWR-In 1 11 + Lamp 13 - PWR-Out 9 10 11 12 13 2 8 3 7 4 6 5 5 7 6 1 PE 2 + Lamp 4 - PWR-In 3 + Lamp 5 - PWR- Out D P S 0 2 - G14 4 8 L1 L2 L3 L4 L5 L6 L7 DPS 02 - A 07 / D C24 P o w e r supply 3 6, 7 8, 9 10, 11 12, 13 14, 15 16, 17 18, 19 2 19 18 17 16 15 14 13 12 11 10 9 S1+ S1- S2 S3 1P 2P 3P 4P 5P 6P 7P 8P 9P 10P11P12P13P14P15P 16P 17P18P 19P20P 21P22P 23P 24P25P26P27P28P29P30P 1 19 18 17 16 15 14 13 12 11 10 9 8 7 6 TEST 42 43 44 45 46 47 48 49 50 51 52 53 1 2 3 5 6 4 5 6 1 2 3 4 Termination resistor CAN CAN Terminal CAN Terminal 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 Termination resistor Seafire System *) 2m 2m 2m 4 X 10m Termination resistor 4 X 50m 8 X 2m Video Recorder AHD-VC VR8 Interface Converter POWER CAN Sensor In 1 5 In 1 2 In 1 3 Fault In 1 4 STOP In 9 E merg. STOP In 1 0 Eme rg. In 1 1 STOP In 6 ST OP Data Station AHD-PS 15 IN16 IN15 IN14 IN13 IN12 IN11 IN10 IN9 IN8 IN7 IN6 IN5 IN4 IN3 IN1 IN2 S3 Opt oIn3Opt oIn3+ Opt oIn2Opt oIn2+ PS15PS15+ RS 485RS 485+ CAN2L CAN2H CAN1L CAN1H -24V +24V Video Distribution Unit AHD-VDCU 16/16 Power supply DANGER S2 TEST Start Stop S1 120 Ext. Signal In 7 START VGA Signal Sec. 60 90 Interval In 8 START Data Station AHD-SAS 15 (Monitoring) Power I gnition In 4 AHD-D EOP Ignit ion In 5 AHD-DEOP AHD-EST In 1 AHD-EST AHD-DAP Signal In 2 AHD-DACP AFT Station In 3 AHD-WOP (Option) AHD-TP 2 2 1 S1+ S1- S2 S3 1P 2P 3P 4P 5P 6P 7P 8P 9P 10P11P12P13P14P15P 24 VDC ±25% 4 3 6 5 8 7 10 12 14 16 9 11 13 15 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 + 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 - U+ U- 1N 2N 3N 4N 5N 6N 7 N 8N 9N 10N11N12N13N14N15N BNC CAN RJ45 CAN 2X Level sensor AHD-S 201 Termination resistor 40m CAN 2m 4 X 30m 5 X 50m 40m 2m 2m serial data 25m AHD-VCS QC 2m 2m BNC CAN Sensor In 1 5 In 1 2 In 1 3 In 1 4 In 9 In 1 0 In 1 1 In 7 In 8 In 4 In 5 In 6 In 1 In 2 In 3 Fault Power Data Station AHD-SAS 15 (Monitoring) CAN Sensor In 1 4 In 1 5 In 1 2 In 1 3 In 9 In 1 0 In 1 1 In 6 In 7 In 8 In 3 In 4 In 5 In 1 In 2 Fault Power Data Station AHD-SAS 15 (Monitoring) VGA RJ45 F-BUS Option DVI VGA Furuno Chart + Option Navigation DVI Signal AHD-VCS QC Pow er supply 2 1 24 VDC ±25% 4 3 6 5 8 7 Power supp ly 10 12 14 16 9 11 13 15 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 2 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 1 4 3 AHD-VC 751 #1 24 VDC ±25% 6 5 8 7 10 12 14 16 9 11 13 15 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 CAN BNC RJ45 AHD-VC 751 #2 Termination resistor AHD-VC 751 #3 AHD-VC 751 #6 AHD-VC 751 #4 AHD-VC 751 #5 AHD-VC 740 #2 Camera in Stbd Anchor Pocket IN30 IN29 IN28 IN27 IN26 IN25 IN24 IN23 IN22 IN21 IN20 IN19 IN18 IN16 IN17 IN15 IN14 IN13 IN12 IN11 IN10 IN9 IN8 IN7 IN6 IN5 IN4 IN3 IN1 IN2 S3 S2 POWER S1 Night Vision Camera (Option) *) BNC RJ45 Binary Data Station AHD-PS 30 S1+ S1- S2 S3 1P 2P 3P 4P 5P 6P 7P 8P 9P 10P11P12P13P14P15P 16P 17P18P 19P 20P21P22P 23P 24P25P26P27P 28P29P30P - VGA AHD-VCS CF 2m + F-BUS DVI CAN 5x Level sensor AHD-S 201 TEST VGA U+ U- 1N 2N 3N 4N 5N 6N 7N 8N 9N 10N11N12N13N14N15N 16N17N18N19N20N21N22N23N24N25N26N27N28N29N30N 24VDC **) AHD-VC 740 #1 Camera in Port Anchor Pocket serial data 24VDC **) AHD-1015 MTC (Engine Room) AHD-1015 MTC (Crew) AHD-1015 MTC (Captain) AH D 101 5TC AHD 1015TC Colour display AHD 880 (Crew) Master TV *) A HD 1 015TC Colour display AHD 880 (Crew) AHD-VCP Colour display AHD 880 (Crew) 15m Camera prev. Camera next P reset Memory P reset next Zoom In Zoom Out Quick Tab CAN Tab VIDEO CAN Video CAN3 CAN2 CAN Video CAN3 CAN2 CAN1 E n ter Video 55m 55m RS232 Power RS232 Failure RS422/485 (1) Failure RS422/485 (1) CAN RS422/485 (2) LAN 8 Rx/Tx9 n.c. 16 Low 18...32 VDC 17 Shield 10 n.c. 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 1 4 6 8 1 5 7 9 25m 25m 25m 25m Main Switchboard LAN 11 R x/Tx+ 10 11 12 13 14 15 16 17 PSU + 2 3 2 3 RS232 12 R x/Tx- 6 GND 13 n.c. 7 Rx/Tx+ 14 n.c. 9 n.c. 10 n.c. 16 Low 17 S hield 5 6 7 8 9 10 11 12 13 14 15 16 17 4 5 7 9 10 11 12 13 14 15 16 17 6 8 Adaptor 15 High 4 CAN RS485 (2) 5 Rx 8 Rx/TxPower supply PSU + 1 2 3 3 CAN 4 Tx LAN 15 High RS485 (1) RS232 14 n.c. RS485 (1) 13 n.c. 7 Rx/Tx+ RS485 (2) 12 Rx/T x- 6 GND CAN 5 Rx 18...32 VDC 2 CAN1 CAN 11 Rx/T x+ 4 Tx LAN Main Engine Port *) Video CAN CAN 40m CAN1 25m Modbus Converter AHD-UIC Power Power supply CAN2 25m 25m 55m RS422/485 (2) Adaptor CAN3 Termination resistor 25m Modbus Converter AHD-UIC VIDEO En ter CAN1 Termination resistor Engine Room Tab VIDEO En ter Main Engine Stbd *) CAN 40m 2m MODBUS RTU MODBUS RTU Power Management System *) GenSets *) *) shipyard supply BNC Signal *) VGA Signal *) CAN Bus Engine DVI Signal CAN Bus Monitoring System CAN Bus Device Control Spill Warning AHD-SW II AHD- SW II 100 CAN Bus Anchor Control 100l remain 95 30 PORT Status AHD-SW II 100 100 95 90 60 Composite Video Cable with BNC Connector Horn *) Outside 95 90 % 100l remain 60 30 STBD 95 90 60 30 P ORT Status 100 90 % 60 30 STBD CAT 5 Cable with RJ45 Connector 8-pole preconfigured Cable Wiring *) Ribbon Cable Wiring *) Power Supply 24VDC +30% / -25% Böning Automationstechnologie GmbH & Co. KG Am Steenöver 4 D-27777 Ganderkesee Tel: +49(0)4221 9475-0 Fax: +49(0)4221 9475-22 [email protected] www.boening.com Beschreibung / Description BIBS Integrated Bridge System with Alarm- und Monitoring System Dateiname / Filename 0012_Schema_Web_en_20100611.tcw Geändert/Modified Datum/Date Dieckmann 11.06.2010 Geprüft/Checked Datum/Date Lg.Nr./Art.no. Seite/Page ##### 1/1 0012_Text_Web_en_20100618.doc Description „BIBS Integrated Bridge System with Alarm and Monitoring System“ The scheme presents a system application for a larger mega yacht with approval of a classification society, where a BIBS Integrated Bridge System is combined with a decentralized designed ship alarm and monitoring system as well as various additional control systems of Böning Automationstechnologie GmbH. BIBS Integrated Bridge System The BIBS Integrated Bridge System is designed as the central control and presentation platform, where all data existing in the system are processed and visualized. Therefore, 19” AHD 1019 colour displays with integrated PC (Panel Computer) are installed in bridge control console, which are controlled by a novel operation concept. By means of a control CAN bus, each AHD 1019 colour display (max. 8 displays) can be selected and operated centrally by an operating panel AHD-DC. Additionally, each AHD-DC unit is combined with an operating panel AHD-DRM T, which allows comfortable control of system menus and operating elements in graphical visualization by means of a trackball. AHD-DC and AHD-DRM T are installed as operating stations within the bridge control console. Anyhow, the units may also be fitted i.e. into the arm rest of the pilot chair. The data of all connected systems are graphically formatted and visualized individually on colour displays with inclusion of ships graphics and general arrangement plans. Following functions are displayed and controlled: Furuno NAVNET 3D for navigation with sea charts and Radar (via DVI interface and integration of the Furuno control via CANUSB converter AHD-CUC) Data visualization of main engines port and starboard (via separated engine CAN bus per engine) Interconnection with ship alarm and monitoring system Tank monitoring system with continuous tank content measurement with hydrostatic tank level probes Door monitoring of all relevant doors, hatches and flaps, alarm signaling depending of ship speed Integration of CCTV camera control (video signal via video input of displays) Display and control of navigation and signal lights Visualization of generator data and power management system from foreign manufacturers Monitoring of fuse automats with remotely operated re-engagement Interfacing of the fire detection system Conning page with convenient presentation of all relevant information like depth sounding progress and indication of roll and pitch movement of the ship Visualization of windlass data with chain link counter and alarm function Control of pumps and valves In order to comply with equipment requirements of classification societies, the BIBS Integrated Bridge System is completed by two additional 19“ colour displays AHD 919. These monitors are approved and certified by classification societies and by national German authority „Bundesamt für Seeschifffahrt und Hydrographie (BSH)” for presentation of Radar and ECDIS sea charts. For each function, Radar and ECDIS sea chart presentation, one monitor is applied. The presentation control is performed directly from the appropriate external system (Furuno). Ship Alarm and Monitoring System The ship alarm and monitoring system is designed decentralized with components for monitoring of ship alarms and status messages. The complete system performance (delay timing, blockings, display texts etc.) is defined by means of a PC based configuration tool. The data communication for transmission of acquired data to the connected operating and display units as well as the system control is performed via three individual CAN bus systems (one engine CAN bus per engine and one CAN bus monitoring system for further ships data). Operating and display units Beside the colour displays of the BIBS Integrated Bridge System, the data of the ship alarm and monitoring system are transmitted via the three CAN bus systems to further colour displays AHD 1015 MTC with touchscreen operation. The units are distributed in different areas of the yacht (engine room, in crew area and in captain´s cabin). The colour displays present all information of the ship alarm and monitoring system on multiple visualization pages with appropriate menu control. A separate alarm table is applied for indication of currently existing alarms, with automatic call at occurrence of a new alarm. Engine CAN Bus The data of main engines port and starboard are transmitted with SAE J1939 protocol via engine CAN bus from the engine electronics of the corresponding engine to the CAN-to-CAN data converter AHD-UCC, which converts the data protocol with required engine data into the Böning AHD-SAS protocol. CAN Bus Monitoring System The remaining data acquisition is performed with components connected to the CAN bus of the monitoring system. Signal data of analog and binary sensors are acquired either directly by connection to data stations or by importing via data communication with data converter units with conversion into the Böning AHD-SAS protocol. The data stations AHD-SAS 15 with CAN bus connection consists of 15 input channels for analog and binary sensors, prepared for connection of sensors with different signal types (current, voltage, resistance, contacts etc.). All input channels can be monitored for sensor failure. Pluggable terminal lists are provided for the connection of sensors. Binary data stations AHD-PS 15 / 30 or 47 consist of 15, 30 resp. 47 input channels for connection of potential free contacts, contacts with single-sided ground connection or contacts, which are switching voltage potentials. The input status is acquired via optocouplers, transformed into a serial output signal and transmitted via a serial interface to a AHD-SAS 15 unit. Each input is provided with an individual status-LED, activated at shorted input. By operation of the TEST push button, each channel can be easily checked for short circuit to earth or ground. A data station AHD-SAS 15 combined with a binary data station AHD-PS 30 is used here especially for integration of the Seafire fire detection system, in order to allow i.e. quick localization of fire alarms of detectors by graphical visualization in deck arrangement plans. Two spill warning gauges AHD-SW II are installed in outdoor deck area for level monitoring of fuel tanks. Each unit consists of LEDscales for level monitoring of two tanks with audible and visual warning at 95% resp. alarm at 100% tank content. Connection and control of the gauge is applied by serial communication with data station AHD-SAS 15. The data converter AHD-UIC consists of two galvanically isolated RS485 interfaces for acquisition of data from external systems via ModBus RTU data protocol. Two of these units are integrated in this system for import of data from generators and from the power management system into the ship alarm and monitoring system. A further CAN-to-CAN data converter AHD-UCC is connected to the CAN bus for monitoring system for data import via CAN bus with NMEA 2000® data protocol from further Furuno devices applied on board of the yacht. The AHD-UCC unit is approved by the NMEA as a „Listen Only NMEA 2000® Certified Product“. Navigation and Signal Light Control and Monitoring AHD-DPS02 For connection, control and monitoring of the navigation and signal lights of the yacht, the AHD-DPS02 system is integrated in the CAN bus monitoring system. The system consists of the basic module AHD-DPS02 G14 for monitoring and control of max. 14 lamps resp. LED-lanterns as well as monitoring of main and emergency power supply (source selectable via separate toggle switch in bridge control console). A further extension module AHD-DPS02 A07 is connected with the basic module via internal bus for extension of the system by additional max. 7 lamps resp. LED-lanterns. The operation of the system is as a standard performed via separate visualization page of connected colour displays. The basic and the extension module are internally connected with an additional operating panel AHD-DPS02 BS2, which also allows monitoring of all 21 navigation and signal light including operation by individual on/off-switches. Video System AHD-VCS The Böning video system AHD-VCS is also applied to the ship alarm and monitoring system via CAN bus monitoring system. The video distribution and control unit AHD-VDCU 16/16 (video cross bar) is provided as the central unit of the system, consisting of each 16 video in- and output channels. In this application, six high resolution Motor Dome cameras AHD-VC 751 with remote controllable pan/tilt/zoom and focus function as well as two anchor pocket cameras AHD-VC 740 for fixed image monitoring of ship anchors are connected to the input channels with RJ45 sockets via a single CAT5 network cable, which includes transmission of video signal, camera control commands and the 12 V DC power supply for the cameras. Each camera is therefore provided with a signal converter unit AHD-VSC C. The anchor pocket cameras are supplied in a set with an additional LED spot light for illumination. The 24 V DC power supply including on/off-switch for the spot light has to be provided by the shipyard. The camera as well as the LED spot light is installed in a submersible IP68 special housing. As an option, the system can be extended via signal converter unit AHD-VSC CF by a Night Vision thermal image camera from Flir Systems. Also optionally, the image presentation for Radar and sea chart can be adapted via DVI interface of the Furuno system to input channels of the video crossbar (signal converter unit AHD-VSC QC). The video output channels of the video crossbar AHD-VDCU 16/16 are equipped with BNC sockets for connection of displays, monitors and television sets with a 75 video coaxial cable (i.e. RG-59). The first 8 video outputs are used in this application for free selection and presentation of video signals from input channels. The selection and the control is performed via operating elements on separate video visualization page of connected multifunction colour displays or, for monitors or television sets, by external video operating unit AHD-VCP with data communication via CAN bus with control software of video crossbar. In this application, the last 8 video outputs are assigned fixed to camera inputs, to ensure a comprehensible video recording with the digital 8-channel video recorder AHD-VC VR8. The video recorder is provided with a 500 GB hard disc for settable recording of video signals (extendable with up to 4 hard discs to max. 2000 GB). The device consists also of monitor outputs for inspection of executed video recordings during running recording operation (VGA interface, resp. CVBS video signal). Additional Control Systems Engine Operation System AHD-EOP/AHD-DEOP Engine operation panels AHD-EOP are installed in bridge control desk per main engine for ignition release as well as for starting and stopping of both main engines. Instead of a conventional starter lock, the AHD-EOP is equipped with a pluggable transponder key for the execution of ignition release. Both AHD-EOP units are connected via internal bus lines with dual operation panels AHD-DEOP. These devices are used for starting and stopping of both main engines, in dependence of inserted transponder key in appropriate AHD-EOP unit. The AHD-DEOP units are cascadable and are installed wing control station port and starboard as well as in AFT station. In compliance with regulations of classification societies, emergency stop units AHD-EST are installed separately for each main engine in bridge control console, wing control station port and starboard as well as in AFT station. The units are connected in series directly with emergency stop circuit in appropriate engine terminal box. The monitoring of the emergency stop circuit is performed by the corresponding engine electronics. Windlass Control AHD-DACP For the up/down control of both windlasses port and starboard, dual windlass control units AHD-DACP are installed in bridge control console, wing control station port and starboard as well as in AFT station. The units are interfaced by a system-own CAN bus and have equal control function. The feedback messages from the anchor system are comfortably visualized on the 19” colour displays. Whistle Control AHD-WOP As a further control system, whistle control unit AHD-WOP is also installed in bridge control console, wing control station port and starboard as well as in AFT station. These units are applied for operation and control of the ship whistle of the yacht. The device is provided with preprogrammed controls for execution of sound signals for maneuvering and warning as well as sound signals in restricted visibility according to “Convention on the International Regulations for Preventing Collisions at Sea, 1972 (COLREGs)”. The devices are interconnected by a serial data link and have equal control function. Search Light Control AHD-SLP (Option) Search light control units AHD-SLP can be installed as an option in bridge control console for on/off- as well as pan/tilt-control of Sunshin HR1012-24V search lights. Thruster Control AHD-TP2 (Option) Also as an option, dual thruster control panels AHD-TP2 can be installed in bridge control console, wing control station port and starboard as well as in AFT station. These units allow comfortable and individual control of two hydraulically and/or VFD (electrically) driven ABT thruster. The devices are interconnected by a serial data link and have equal control function.