001694spc-02 - Rh-12-hac Single Stage R410a 230-1-60

   EMBED


Share

Transcript

ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd. P.O. Box 2555 Petitcodiac, N.B. E4Z 6H4 Ph. (506) 756-8135 Email: [email protected] Web: www.nordicghp.com Document Number: 001694SPC-02 DATE: 24-July-2015 MODEL NOMENCLATURE RH—12—HAC—P—1L—C—SDELF—xx Series: RH = Horizontal Liquid to Air Revision: 01, 02 etc. Nominal Size: 12 = 1 Ton Fan Discharge: F= Field Configurable Functions: H = Heating AC = Active Cooling Fan Return: L= Left Hand Return R= Right Hand Return Fan Motor: E = ECM (Variable Speed) Refrigerant: P = R410a Fan Type: D = Direct Drive Voltage Code: 1 = 208/230-1-60 Air Coil: S = Standard Compressor Stages: L = 1 Stage rotary Outdoor Loop Exchanger: C = Copper The models and revisions covered by this document are listed in the table below. MODEL REVISION RH-12-HAC-P-1L-C-SDELF 02 RH-12-HAC-P-1L-C-SDERF 02 Maritime Geothermal Ltd. has a continuous improvement policy and reserves the right to modify specification data at any time without prior notice . 24-July-2015 Page 2 001694SPC-02 NORDIC® DESIGN FEATURES LIST The heat pump described in this specification document comes with the following features:                          CSA certified for safety (CSA 22.2 No 236-05). 20ga satin galvanized case with reinforcing channel stiffeners and corner posts. Corner brackets for hanger applications. Acoustically insulated cabinet (1/2” thick) ECM fan motor with removable blower for changing blower motor Field configurable fan outlet, side or end. Air filter accessible from either end of rack. ABS condensate drip tray. Condensate drain with 3/4” PVC FPT connection. Condensate overflow protection. Multi-circuit high efficiency air-coil. Refrigeration service ports located inside unit (1/4” Schrader) Insulated copper coaxial heat exchangers and piping 1/2” brass FPT fittings for Outdoor Loop connections. High efficiency single stage rotary compressor Double grommet compressor isolation for reduced noise and vibration. Suction line accumulator Liquid line filter-dryer Liquid line sight glass Balanced port Thermostatic Expansion Valve with internal bleed 4-way reversing valve High and low pressure safety controls Control board with random start, anti-short cycle timer, 3 re-start attempts and permanent lockout mode. Electrical box layout and schematic diagrams Installation and service manual OPTIONAL EQUIPMENT The following is a list of optional equipment that may be ordered with the heat pump:     Programmable thermostat. Circulator pump module with loop / unit isolation valves (230VAC) for ground loop applications. Various adapters for unit and loop connections to pump module. Electric plenum heater 24-July-2015 Page 3 001694SPC-02 NORDIC® DESIGN FEATURES Heavy duty cabinet, satin galvanized with powder coated doors for premium appearance Cabinet completely insulated with 1/2” acoustic insulation. Multi-circuit high efficiency air coil. Condensate drain with 3/4” PVC FPT connection. Fault monitoring board with random start, lock -out indicator and antishort cycle timer. ABS condensate drip tray. Bi-flow filter dryer. Corner hangers for concealed ceiling applications. Balanced port TXV with external equalization port. 1/2” Brass FPT fittings for Outdoor Loop connections. Field replaceable variable speed ECM fan motor with ball bearings and resilient mounting bracket. Field configurable fan outlet: SIDE or END Suction line accumulator. Dual mount compressor for reduced noise and vibration. Sight glass. High efficiency LG® rotary compressor. 24-July-2015 Page 4 High & Low 4-way refrigerant reversing access ports. valve. Insulated High Efficiency Turbotec® coaxial heat exchanger. Resistant to accidental freezing. 001694SPC-02 DIMENSIONS - LEFT RETURN 24-July-2015 Page 5 001694SPC-02 DIMENSIONS - RIGHT RETURN 24-July-2015 Page 6 001694SPC-02 ELECTRICAL BOX LAYOUT Legend 13. 14. 15. 16. compressor contactor run capacitor 40VA control transformer thermostat terminal strip 17. ground lug 18. condensate overflow safety control 19. control board ELECTRICAL SPECIFICATIONS Heat Pump Electrical Information Voltage Identifier 1 V-ø-Hz MIN MAX RLA LRA RLA Circ. Pump Max. A 208/230-1-60 187 253 5.5 26 2.8 1.5 Power Supply Compressor Fan Amps Max. Fuse / Breaker Amps Minimum Wire Size ga 11.4 15 #14-2 FLA MCA Amps 10.0 MISCELLANEOUS INFORMATION Unit Weight Lbs. kg Refrigerant Type 172 78 R410a Refrigerant Charge Nominal Airflow Lbs. kg CFM L/s 2.0 0.91 400 189 MINIMUM AND MAXIMUM OPERATING TEMPERATURES* Loop Outdoor Indoor (Duct) Parameter Mode (°F) (°C) Note Minimum ELT Heating / Cooling 41 5 Ground water system. Minimum ELT Heating / Cooling 23 -5 Ground loop system. Adequate freeze protection required. Maximum ELT Heating 80 27 Maximum ELT Cooling 110 43 Minimum EAT Heating / Cooling 60 16 Maximum EAT Heating 80 27 Reduce air flow if necessary during heating startup. * Values in this table are for rated liquid and airflow values. 24-July-2015 Page 7 001694SPC-02 ELECTRICAL DIAGRAMS (208/230-1-60) 24-July-2015 Page 8 001694SPC-02 REFRIGERATION CIRCUIT DIAGRAMS 24-July-2015 Page 9 001694SPC-02 REFRIGERATION CIRCUIT DIAGRAMS (continued) 24-July-2015 Page 10 001694SPC-02 STANDARD CAPACITY RATINGS The tables below depict the results of standard capacity rating tests according to C13256-1 standards. C13256-1 is identical to ISO13256-1. Standard Capacity Ratings - Ground Loop Heating* 60Hz EAT 68°F (20°C) Model 12 ELT 32°F (0°C) Liquid Flow USG 3.0 L/s 0.189 Pressure Drop PSI 3.5 kPA 24.1 Airflow CFM 400 L/s 189 Input Energy Watts 920 Capacity BTU/Hr 11,800 kW 3.5 COPH W/W 3.75 * 15% NaCl by Weight Ground Loop Fluid Standard Capacity Ratings - Ground Water Heating EAT 68°F (20°C) Model 12 ELT 50°F (10°C) Liquid Flow USG 3.0 60Hz L/s 0.189 Pressure Drop PSI 3.2 kPA 22.1 Airflow CFM 400 L/s 189 Input Energy Watts 945 Capacity BTU/Hr 13,500 kW 4.0 Standard Capacity Ratings - Ground Loop Cooling* EAT 80.6°F (27°C) Model 12 W/W 4.18 60Hz ELT 77°F (25°C) Liquid Flow USG 3.0 COPH L/s 0.189 Pressure Drop PSI 3.3 kPA 22.7 Airflow CFM 400 L/s 189 Input Energy Watts 740 Capacity BTU/Hr 12,800 kW 3.8 COPH W/W 5.07 * 15% NaCl by Weight Ground Loop Fluid Standard Capacity Ratings - Ground Water Cooling EAT 80.6°F (27°C) Model 12 24-July-2015 ELT 59°F (15°C) Liquid Flow USG 3.0 60Hz L/s 0.189 Pressure Drop PSI 3.1 kPA 21.4 Airflow CFM 400 Page 11 L/s 189 Input Energy Watts 600 Capacity BTU/Hr 13,600 kW 3.9 COPH W/W 6.64 001694SPC-02 CAPACITY RATINGS Heating Mode RH-12-HAC-P-1L Source Data (Outdoor Loop) Nominal 1 ton Power Consumption ELT Evap. Temp Flow LLT Delta T HAB Compressor Fan* °F °C °F °C USGPM L/s °F °C °F °C BTU/Hr Watts Watts Amps Watts Watts 29.0 20 3.0 23.1 5.9 8,397 104 916 -1.7 -6.7 0.189 -4.9 3.3 2,460 35.0 25 3.0 28.8 6.2 8,862 1.7 -3.9 0.189 -1.8 3.5 2,597 41.0 30 3.0 34.5 6.5 9,314 5.0 -1.1 0.189 1.4 3.6 2,729 47.0 35 3.0 40.1 6.9 9,794 8.3 1.7 0.189 4.5 3.8 2,870 51.0 40 3.0 44.0 7.0 10,523 10.6 4.4 0.189 6.7 3.9 3,083 57.0 45 3.0 49.3 7.7 11,528 13.9 7.2 0.189 9.6 4.3 3,378 63.0 50 3.0 54.7 8.3 12,506 17.2 10.0 0.189 12.6 4.6 3,664 69.0 55 3.0 60.1 8.9 13,309 20.6 12.8 0.189 15.6 4.9 3,899 812 3.7 824 3.7 EAT Cond. Temp. Flow LAT Delta T Net Output W/W °F °C °F °C CFM L/min °F °C °F °C BTU/Hr Watts 3.69 68 102 400 96.8 28.8 11,523 20.0 38.9 189 36.0 16.0 3,376 Effective COPh 104 928 3.80 834 3.8 104 938 3.91 835 3.8 104 939 4.06 843 3.9 104 947 4.26 859 3.9 104 963 4.51 875 4.0 104 979 4.74 887 4.1 104 991 R410a 60 Hz Sink Data (Indoor Loop) 4.94 68 104 400 98.1 30.1 12,029 20.0 40.0 189 36.7 16.7 3,525 68 106 400 99.3 31.3 12,514 20.0 41.1 189 37.4 17.4 3,666 68 108 400 100.5 32.5 12,997 20.0 42.2 189 38.1 18.1 3,808 68 110 400 102.4 34.4 13,754 20.0 43.3 189 39.1 19.1 4,030 68 112 400 105.0 37.0 14,815 20.0 44.4 189 40.6 20.6 4,341 68 114 400 107.6 39.6 15,847 20.0 45.6 189 42.0 22.0 4,643 68 116 400 109.7 41.7 16,689 20.0 46.7 189 43.2 23.2 4,890 * @ 24.9Pa (0.10inH2o) Ext. Static Compressor: GKS120KAB Cooling Mode RH-12-HAC-P-1L Source Data (Indoor Loop) EAT Evap. Airflow Temp LAT Delta T Latent Sensible °F °C °F °C CFM L/s °F °C °F °C BTU/Hr BTU/Hr Watts Watts 80.6 44 400 57.0 23.6 4,433 9,421 Power Consumption HAB BTU/Hr Watts 13,854 27.0 6.7 189 13.9 13.1 1,299 2,760 4,059 80.6 44 400 57.4 23.2 4,367 9,281 13,648 27.0 6.8 189 14.1 12.9 1,280 2,719 3,999 80.6 44 400 57.7 22.9 4,308 9,154 13,462 27.0 6.9 189 14.3 12.7 1,262 2,682 3,944 80.6 45 400 58.1 22.5 4,242 9,014 13,256 27.0 7.0 189 14.5 12.5 1,243 2,641 3,884 80.6 45 400 58.4 22.2 4,178 8,877 13,055 27.0 7.1 189 14.7 12.3 1,224 2,601 3,825 80.6 45 400 58.8 21.8 4,104 8,722 12,826 27.0 7.2 189 14.9 12.1 1,203 2,555 3,758 80.6 45 400 59.2 21.4 4,021 8,546 12,567 27.0 7.3 189 15.1 11.9 1,178 2,504 3,682 80.6 45 400 59.6 21.0 3,945 8,383 12,328 27.0 7.4 189 15.4 11.6 1,156 2,456 3,612 Compressor ELT Cond. Temp. Flow LLT Watts EER COPc °F °C °F °C USGPM L/s °F °C 27.8 51 70 3.0 382 2.2 116 498 451 2.4 116 567 8.15 24.1 7.06 514 2.6 116 630 21.4 6.26 550 2.7 116 666 578 2.8 116 694 19.9 5.83 18.8 5.51 626 2.9 116 742 17.3 5.07 671 3.1 116 787 715 3.3 116 831 16.0 4.68 14.8 4.35 10.6 21.1 56 75 13.3 23.9 61 80 16.1 26.7 66 85 18.9 29.4 72 90 22.2 32.2 77 95 25.0 35.0 82 100 27.8 37.8 87 105 30.6 40.6 5.8 4,574 5.8 4,550 6.0 4,519 6.0 4,500 92.7 10.7 15,253 0.189 33.7 3.0 4,566 87.8 10.8 15,358 0.189 31.0 3.0 5.8 82.8 10.8 15,425 0.189 28.2 3.0 4,557 76.4 10.4 15,530 0.189 24.6 3.0 5.8 71.4 10.4 15,612 0.189 21.9 3.0 BTU/Hr Watts 66.4 10.4 15,583 0.189 19.1 3.0 °F °C 61.4 10.4 15,554 0.189 16.3 3.0 Delta Rejection T 5.9 4,469 97.6 10.6 15,164 0.189 36.5 5.9 4,443 * @ 24.9Pa (0.10inH2o) Ext. Static Compressor: GKS120KAB 24-July-2015 Efficiency Fan* Effective Watts Amps Watts R410a 60 Hz Sink Data (Outdoor Loop) Page 12 001694SPC-02 LIMITED WARRANTY MARITIME GEOTHERMAL LTD. warrants that its commercial geothermal heat pumps shall be free from defects in materials and workmanship for a period of ONE (1) YEAR after the date of installation or for a period of ONE (1) YEAR AND SIXTY (60) DAYS after the date of shipment, whichever occurs first. This warranty covers all internal components of the heat pump. MARITIME GEOTHERMAL LTD. shall, at its option, repair or replace any part covered by this warranty. Defective parts shall be returned to MARITIME GEOTHERMAL LTD., transportation charges prepaid. Replacement or repaired parts and components are warranted only for the remaining portion of the original warranty period. This warranty is subject to the following conditions: 1. The geothermal heat pump must be properly installed and maintained in accordance with MARITIME GEOTHERMAL LTD. guidelines. 2. The installer must complete the Startup Record and return it to MARITIME GEOTHERMAL LTD. within 21 days of unit installation. 3. For new construction, it is the responsibility of the building or general contractor to supply temporary heat to the structure prior to occupancy. Geothermal heat pumps are designed to provide heat only to the completely finished and insulated structure. Startup of the unit shall not be scheduled prior to completion of construction and final duct installation for validation of this warranty. 4. It is the customer's responsibility to supply the proper quantity and quality of water or properly sized ground loop with adequate freeze protection. If a geothermal heat pump manufactured by MARITIME GEOTHERMAL LTD. fails to conform to this warranty, MARITIME GEOTHERMAL LTD.'s sole and exclusive liability shall be, at its option, to repair or replace any part or component which is returned by the customer during the applicable warranty period set forth above, provided that (1) MARITIME GEOTHERMAL LTD. is promptly notified in writing upon discovery by the customer that such part or component fails to conform to this warranty; (2) the customer returns such part or component to MARITIME GEOTHERMAL LTD., transportation charges prepaid, within (30) thirty days of failure, and (3) MARITIME GEOTHERMAL LTD.'s examination of such component discloses to its satisfaction that such part or component fails to conform to this warranty and the alleged defects were not caused by accident, misuse, neglect, alteration, improper installation, repair or improper testing. MARITIME GEOTHERMAL LTD. will not be responsible for any consequential damages or labour costs incurred. In additional, MARITIME GEOTHERMAL LTD. will not be responsible for the cost of replacement parts purchased from a third party. 24-July-2015 Page 13 001694SPC-02