GOLD Sizing, Installation, Dimensions and Weights The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be carried out in the ProUnit air handling unit selection program. Contents Prerequisites for Sizing..................................................................................................... 43 GOLD RX, One-piece air handling units with rotary heat exchanger ........................... 44 GOLD PX, One-piece air handling units with plate heat exchanger ............................. 74 GOLD CX, One-piece air handling units with coil heat exchanger ............................... 90 GOLD SD, Supply air and extract air handling units ................................................... 102 We reserve the right to alter specifications. 20090415 www.swegon.com 41 GOLD 42 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Prerequisites for Sizing Fan Charts The SFPV chart on the following pages indicates the fanpower efficiency rating of the air handling unit computed according to Swedish Ventilation guidelines (V Publication 1995:1, Revision 2000). The SFPV should be calculated according to guidelines in the V Publication under clean filter load conditions. GOLD RX/PX/CX The SFPV and Extract Air Fan Charts are computed on condition that the supply and extract air fans generate the same airflow and available total pressure rise. Consideration has been taken to leakage and purging air flows and extra pressure drop in the extract air required to ensure the correct leakage airflow direction under pressure conditions that conform to a normal installation under a specific available pressure conditions. Acoustic calculations The sound emitted by Swegon products is measured according to the method defined in ISO 5136, the most widely used method in Europe. Acoustic measurements are sometimes taken using other methods. The total sound power level LW, tot emitted from the fan outlet to the ducting can be read from each of the fan charts. The following formula can be used for breaking down the total sound power level into octave bands: LW, ok = LW, tot + Kok. Kok can be obtained from the tables on the following pages. The Extract Air Fan and Supply Air Fan Charts indicate available total pressure rise to cover duct pressure drop and external functional sections, and total sound power level LW, tot emitted to connecting outlet duct, dB (relative to 10 -12 W), in the 125 – 8 000 Hz octave band frequencies. Available pressure rise, based on the design pressure drop across filters, is specified in all the charts. The blue broken line defines range numbers (1,2,3,4) for details on correction factors KOK in a specific table. Range 1 is most favourable from an acoustic point of view. GOLD SD The Fan Charts indicate the total pressure rise to cover possible internal total pressure losses for, e.g. filter, duct pressure drop and external functional sections, and total sound power level LW, tot emitted to a connecting outlet duct, dB (relative to 10-12 W), in the 125 – 8,000 Hz octave band frequencies. The total pressure loss for an optional filter (all sizes), coil heat exchanger and droplet eliminator (sizes 14-80) are specified in the lower chart. The blue broken line defines the limits of the numbered ranges (1,2,3,4) for particulars of the correction factors KOK in a separate table. Range 1 is the most favourable range from an acoustic point of view. We reserve the right to alter specifications. 20090415 www.swegon.com 43 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 04 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 Supply air fan 2 1 L w,tot 75dB 80 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 04 288 0,08 Max. airflow m3 /h m3 /s 1620 0,45 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 0 -10 -12 -5 -4 -11 -13 -8 -10 0 -5 -6 -13 -16 -25 To the inlet duct* 1 2 -5 -2 -10 -17 -4 -10 -15 -19 -28 -30 -28 -33 -32 -40 -45 -46 To the AHU surroundings** 1 2 -14 -24 -35 -32 -11 -19 -27 -34 -41 -43 -33 -38 -40 -47 -47 -56 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 44 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 04 Delivery and transport within the site The GOLD RX 04 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The air handling unit is supplied on a wooden pallet. Stand/Base The design of the GOLD RX 04 makes it necessary to mount it on a stand or other form of base. Otherwise it will not be possible to open the inspection doors of the unit. Right-hand version The stand is available as an accessory. Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The air handling unit can be installed up ended. Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply Size A B C D E F G H I L Ø Weight, kg 04 750 820 236 345 239 268 385 920 267 1500 315 258 Clear space for inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 04: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A The air handling unit is internally wired for a single-phase, 230 V supply. Therefore ensure a correct neutral connection when connecting to a 3phase, 400 V power supply. Rated data per fan GOLD 04: 3 x 230 V, 50 Hz, 1.1 kW (0.55 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 45 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 05 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa 4 Extract air fan 2 3 1 L w,tot 75dB 80 4 85 2 Supply air fan 3 1 L w,tot 75dB 80 85 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 05 288 0,08 Max. airflow m3 /h m3 /s 2230 0,62 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 3 4 -3 -10 -12 -5 -11 -10 0 -5 -4 11 -6 -5 -11 -14 -13 -10 -8 -5 -10 -7 0 -1 -5 -4 -6 -7 -13 -10 -16 -14 -25 -20 To the inlet duct* 1 2 3 4 -5 -9 -2 2 -10 -11 -4 -8 -17 -18 -10 -12 -15 -25 -19 -18 -28 -26 -30 -28 -28 -26 -33 -32 -32 -32 -40 -37 -45 -47 -46 -48 To the AHU surroundings** 1 2 3 4 -14 -16 -11 0 -24 -25 -19 -20 -35 -32 -33 -35 -27 -34 -28 -31 -41 -38 -43 -40 -33 -34 -38 -37 -40 -41 -47 -44 -47 -45 -56 -51 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 46 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 05 Delivery and transport within the site The GOLD RX 05 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The air handling unit is supplied on a wooden pallet. Stand/Base The design of the GOLD RX 05 makes it necessary to mount it on a stand or other form of base. Otherwise it will not be possible to open the inspection doors of the unit. Right-hand version The stand is available as an accessory. Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The air handling unit can be installed up ended. Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply Size A B C D E F G H I L Ø Weight, kg 05 750 820 236 345 239 268 385 920 267 1500 315 258 Clear space for inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 05: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 16 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A The air handling unit is internally wired for a single-phase, 230 V supply. Therefore ensure a correct neutral connection when connecting to a 3phase, 400 V power supply. Rated data per fan GOLD 05: 3 x 230 V, 50 Hz, 1.1 kW We reserve the right to alter specifications. 20090415 www.swegon.com 47 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 08 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 85 Supply air fan 2 1 L w,tot 75dB 80 85 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 08 360 0,10 Max. airflow m3 /h m3 /s 3240 0,90 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 1 2 -4 -4 -6 -8 -10 -9 -12 -11 -11 -9 -15 -12 -27 -24 To the inlet duct* 1 2 -2 -2 -3 -9 -4 -10 -14 -15 -27 -30 -31 -31 -38 -36 -46 -34 To the AHU surroundings** 1 2 -10 -18 -29 -31 -9 -18 -31 -30 -45 -44 -44 -42 -49 -46 -58 -55 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 48 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 08 Delivery and transport within the site The GOLD RX 08 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The air handling unit is supplied on a wooden pallet. Stand/Base The design of the GOLD RX 08 makes it necessary to mount it on a stand or other form of base. Otherwise it will not be possible to open the inspection doors of the unit. Right-hand version The stand is available as an accessory. Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The air handling unit can be installed up ended. Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply Size A B C D E F G H I L Ø Weight, kg 08 800 990 274 440 276 293 500 1085 292 1600 400 313 Clear space for inspection A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 08: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 20 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A The air handling unit is internally wired for a single-phase, 230 V supply. Therefore ensure a correct neutral connection when connecting to a 3phase, 400 V power supply. Rated data per fan GOLD 08: 3 x 230 V, 50 Hz, 1.4 kW We reserve the right to alter specifications. 20090415 www.swegon.com 49 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 12 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan Will be available later! Supply air fan Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 12 720 0,20 Max. airflow m3 /h m3 /s 4680 1,30 Ljudväg Område i Oktavband, nr / medelfrekvens, Hz 1 2 3 4 5 6 Will be available later! diagram 7 8 63 125 250 500 1000 2000 4000 8000 Till utlopps- kanal 1 2 -3 1 -12 -14 -8 -9 -3 -5 -6 -6 -9 -8 -7 -9 -15 -19 Till inlopps- kanal* 1 2 -8 -3 -14 -23 -5 -12 -14 -14 -31 -30 -31 -31 -38 -36 -31 -33 Till aggregatets omgivning** 1 2 -14 -26 -37 -10 -22 -32 -24 -26 -39 -39 -42 -41 -41 -43 -46 -50 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 50 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 12 Delivery and transport within the site The GOLD RX 12 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Fan arrangement 2 Fan arrangement 1 Installation/duct connection options Right-hand version A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply K 16 J 50 50 K 16 52 52 J 50 50 The dimension print shows the connection configuration for fan arrangement 1. For fan arrangement 2 the connections are mirror-inverted. Size A B C D F G H J K L Ø Weight, kg 12 655 1199 324 550 324 647 1295 935 551 1860 500 518 Clear space for inspection Division into sections for transport within the site A D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 14: A = 132 kg, D = 155 kg. We reserve the right to alter specifications. A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 12: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 12: Motor shaft power: 1.6 kW, motorized control: 3 x 400 V, 50 Hz 20090415 www.swegon.com 51 GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 12 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan Will be available later! Supply air fan Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 12 720 0,20 Max. airflow m3 /h m3 /s 4680 1,30 Ljudväg Område i Oktavband, nr / medelfrekvens, Hz 1 2 3 4 5 6 Will be available later! diagram 7 8 63 125 250 500 1000 2000 4000 8000 Till utlopps- kanal 1 2 -3 1 -12 -14 -8 -9 -3 -5 -6 -6 -9 -8 -7 -9 -15 -19 Till inlopps- kanal* 1 2 -8 -3 -14 -23 -5 -12 -14 -14 -31 -30 -31 -31 -38 -36 -31 -33 Till aggregatets omgivning** 1 2 -14 -26 -37 -10 -22 -32 -24 -26 -39 -39 -42 -41 -41 -43 -46 -50 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 52 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX Top, rotary heat exchanger, size 12 Delivery and transport within the site The GOLD RX 12 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Left-hand version Installation/duct connection options A: The COMPACT Top unit is produced in one variant in which all the components are arranged at their given physical location inside the unit. All the duct connections are arranged from the top of the air handling unit. B: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. 16 Outdoor air Supply air Right-hand version Extract air Exhaust air 16 52 52 J 50 50 Connection to Power Supply C K C Size A B C D F G H J K L Ø Weight, kg Top 12 655 1199 332 550 333 533 1295 935 1196 1860 500 504 Clear space for inspection Division into sections for transport within the site A D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 14: A = 125 kg, D = 155 kg. We reserve the right to alter specifications. A clear space of 800 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 12: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 12: Motor shaft power: 1.6 kW, motorized control: 3 x 400 V, 50 Hz 20090415 www.swegon.com 53 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 14 Airflow, m3/h 2.5 SFP v 2.0 1.5 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 Supply air fan 2 1 L w,tot 75dB 80 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 14 720 0,20 Max. airflow m3 /h m3 /s 3960 1,10 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 1 -12 -14 -8 -9 -3 -5 -6 -6 -9 -8 -7 -9 -1 -19 To the inlet duct* 1 2 -8 -3 -14 -23 -5 -12 -14 -14 -31 -30 -31 -31 -38 -36 -31 -33 To the AHU surroundings** 1 2 -14 -26 -37 -10 -22 -32 -24 -26 -39 -39 -42 -41 -41 -43 -46 -50 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 54 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 14 Delivery and transport within the site The GOLD RX 14 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Upward Upward Forward A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. D: Specify when ordering whether the unit shall have an air intake from above for outdoor air or extract air. Fan arrangement 2 Fan arrangement 1 Installation/duct connection options Forward Right-hand version Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply E 28 28 50 Size A B C D E F G H I J K L Weight, kg 14 765 1295 1036 550 196 400 1000 1295 252 122 146 2080 634 Clear space for inspection Division into sections for transport within the site A 50 D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 14: A = 235 kg, D = 164 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 14: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 14: 3 x 400 V, 50 Hz, 3.0 kW (1.2 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 55 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 20 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa 2 1 L w,tot 75dB 80 85 90 Supply air fan 2 1 L w,tot 75dB 80 85 90 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 20 720 0,20 Max. airflow m3 /h m3 /s 6480 1,80 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 1 -12 -14 -8 -9 -3 -5 -6 -6 -9 -8 -7 -9 -15 -19 To the inlet duct* 1 2 -8 -3 -14 -23 -5 -12 -14 -14 -31 -30 -31 -31 -38 -36 -31 -33 To the AHU surroundings** 1 2 -14 -26 -37 -10 -22 -32 -24 -26 -39 -39 -42 -41 -41 -43 -46 -50 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 56 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 20 Delivery and transport within the site The GOLD RX 20 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Forward Fan arrangement 2 Fan arrangement 1 Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. D: Specify when ordering whether the unit shall have an air intake from above for outdoor air or extract air. Upward Upward Forward Right-hand version Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply E 28 28 50 Size A B C D E F G H I J K L Weight, kg 20 765 1295 1036 550 196 400 1000 1295 252 122 146 2080 634 Clear space for inspection Division into sections for transport within the site A 50 D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 20: A = 235 kg, D = 164 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 20: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 20: 3 x 400 V, 50 Hz, 3.0 kW 20090415 www.swegon.com 57 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 25 Airflow, m3/h SFP v 2.5 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 Supply air fan 2 1 L w,tot 80dB 85 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 Size Min. airflow m3 /h m3 /s Max. airflow m3 /h m3 /s To the outlet duct 1 2 -8 1 -7 -6 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 GOLD 25 1080 7920 To the inlet duct* 1 2 -10 -14 -14 -5 -9 -14 -19 -27 -28 -30 -28 -32 -33 -33 -33 -32 To the AHU surroundings** 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 0,30 2,20 -15 -6 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 58 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 25 Delivery and transport within the site The GOLD RX 25 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Upward Upward Forward Fan arrangement 2 Fan arrangement 1 Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. D: Specify when ordering whether the unit shall have an air intake from above for outdoor air or extract air. Forward Right-hand version Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply E 28 28 50 Size A B C D E F G H I J K L Weight, kg 25 835 1595 1336 550 180 500 1200 1596 300 148 194 2220 836 Clear space for inspection Division into sections for transport within the site A 50 D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 25: A = 310 kg, D = 216 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 25: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 25: 3 x 400 V, 50 Hz, 4.6 kW (2.3 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 59 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 30 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 90 Supply air fan 2 1 L w,tot 80dB 85 90 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 30 1080 0,30 Max. airflow m3 /h m3 /s 10800 3,00 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -8 1 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 To the inlet duct* 1 2 -10 -14 -14 -19 -5 -9 -14 -27 -28 -30 -28 -32 -33 -33 -33 -32 To the AHU surroundings** 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 -15 -6 -7 -6 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 60 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 30 Delivery and transport within the site The GOLD RX 30 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Upward Upward Forward Forward Installation/duct connection options Fan arrangement 2 Fan arrangement 1 A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. D: Specify when ordering whether the unit shall have an air intake from above for outdoor air or extract air. Right-hand version Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply E 28 28 50 Size A B C D E F G H I J K L Weight, kg 30 835 1595 1336 550 180 500 1200 1596 300 148 194 2220 836 Clear space for inspection Division into sections for transport within the site A 50 D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 30: A = 310 kg, D = 216 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 30: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 20 A Rated data per fan GOLD 30: 3 x 400 V, 50 Hz, 4.6 kW 20090415 www.swegon.com 61 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 35 Airflow, m3/h SFP v 2.5 2.0 1.5 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 85 Supply air fan 2 1 L w,tot 75dB 80 85 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s Max. airflow m3 /h m3 /s GOLD 35 2160 11160 0,60 3,10 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -6 1 -7 -5 -6 -4 -5 -5 -7 -8 -7 -12 -20 -25 To the inlet duct* 1 2 -10 -16 -15 -1 -3 -13 -21 -28 -31 -29 -29 -32 -38 -37 -43 -36 To the AHU surroundings** 1 2 -17 -29 -30 -10 -23 -28 -27 -25 -38 -38 -40 -41 -41 -46 -51 -56 -15 -9 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 62 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 35 Delivery and transport within the site The GOLD RX 35 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Fan arrangement 2 Fan arrangement 1 Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. Right-hand version Upward Upward Forward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 50 Size A B C D E F G H I J K L Weight, kg 35 875 1885 1626 550 125 600 1400 1885 300 192 242 2300 1100 Clear space for inspection Division into sections for transport within the site A 50 D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 35: A = 405 kg, D = 290 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 35: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 35: 3 x 400 V, 50 Hz, 6.5 kW (3.1 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 63 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 40 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Extract air fan Available total pressure rise, Pa 2 1 L w,tot 75dB 80 85 90 95 Supply air fan 2 1 L w,tot 75dB 80 85 90 95 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 40 2160 0,60 Max. airflow m3 /h m3 /s 14760 4,10 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -6 1 -7 -5 -6 -4 -5 -5 -7 -8 -7 -12 -20 -25 To the inlet duct* 1 2 -10 -16 -15 -1 -3 -13 -21 -28 -31 -29 -29 -32 -38 -37 -43 -36 To the AHU surroundings** 1 2 -17 -29 -30 -10 -23 -28 -27 -25 -38 -38 -40 -41 -41 -46 -51 -56 -15 -9 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 64 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 40 Delivery and transport within the site The GOLD RX 40 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. Fan arrangement 2 Fan arrangement 1 Installation/duct connection options A: The air handling unit is supplied in a right-hand version. The unit can be changed to the left-hand version at the building site by a simple modification in the control equipment. Right-hand version Upward Upward Forward Forward B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 50 Size A B C D E F G H I J K L Weight, kg 40 875 1885 1626 550 125 600 1400 1885 300 192 242 2300 1100 Clear space for inspection Division into sections for transport within the site A 50 D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 40: A = 405 kg, D = 290 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 40: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 32 A Rated data per fan GOLD 40: 3 x 400 V, 50 Hz, 6.5 kW 20090415 www.swegon.com 65 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 50 Airflow, m3/h 2.5 SFP v 2.0 1.5 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 90 Supply air fan 2 1 L w,tot 80dB 85 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 50 2880 0,80 Max. airflow m3 /h m3 /s 16560 4,60 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -12 -17 -12 -5 -8 -9 -7 -7 -6 -6 -6 -7 -7 -11 -21 -23 To the inlet duct* 1 2 -16 -18 -14 -6 -8 -11 -12 -19 -31 -28 -26 -27 -38 -37 -43 -36 To the AHU surroundings** 1 2 -23 -31 -35 -16 -22 -32 -28 -28 -39 -39 -39 -40 -41 -45 -52 -54 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 66 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 50 Delivery and transport within the site The GOLD RX 50 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel.Installation/duct connection options Fan arrangement 1 A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 2 Right-hand version Upward Upward Forward C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air 34 Connection to Power Supply 28 28 76 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. Size A B D E F G H I J K L Weight, kg 50 1050 2318 570 150 800 1600 2253 423 115 360 2670 1690 Clear space for inspection Division into sections for transport within the site A D A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 50: A = 638 kg, D = 414 kg. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 50: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 25 A Rated data per fan GOLD 50: 3 x 400 V, 50 Hz, 4.6 kW (2.3 kW)* two parallel fans *) The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 67 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 60 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 90 95 Supply air fan 2 1 L w,tot 80dB 85 95 90 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 60 2880 0,80 Max. airflow m3 /h m3 /s 21600 6,00 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -12 -17 -12 -5 -8 -9 -7 -7 -6 -6 -6 -7 -7 -11 -21 -23 To the inlet duct* 1 2 -16 -18 -14 -6 -8 -11 -12 -19 -31 -28 -26 -27 -38 -37 -43 -36 To the AHU surroundings** 1 2 -23 -31 -35 -16 -22 -32 -28 -28 -39 -39 -39 -40 -41 -45 -52 -54 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 68 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 60 Delivery and transport within the site The GOLD RX 60 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Upward Forward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel. Fan arrangement 1 Fan arrangement 2 Right-hand version Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Upward Upward Forward C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air 34 Connection to Power Supply 28 28 76 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. Size A B D E F G H I J K L Weight, kg 60 1050 2318 570 150 800 1600 2253 423 115 360 2670 1690 Clear space for inspection Division into sections for transport within the site A D A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 60: A = 638 kg, D = 414 kg. We reserve the right to alter specifications. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 60: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 40 A Rated data per fan GOLD 60: 3 x 400 V, 50 Hz, 4.6 kW, two parallel fans 20090415 www.swegon.com 69 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 70 Airflow, m3/h 2.5 SFP v 2.0 1.5 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan 2 L w,tot 1 80dB 85 90 Supply air fan 2 1 L w,tot 80dB 90 85 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 70 3600 1,00 Max. airflow m3 /h m3 /s 22680 6,30 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -14 -16 -3 -6 -11 -19 -22 -30 -27 -29 -31 -38 -37 -43 -36 To the AHU surroundings** 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 70 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 70 Delivery and transport within the site The GOLD RX 70 is always supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section where the fan is located in the lower level. Upward Upward Forward The air handling unit can be split into three sections to facilitate transporting it within the building site. Forward Fan arrangement 1 The three sections are joined together by bolts and the electrical and control cables have quick connectors. Fan arrangement 2 Right-hand version The unit is delivered on 100 mm high support feet made of steel. Upward Upward Forward Installation/duct connection options Forward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 Fan arrangement 2 Left-hand version C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 76 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. Size A B D E F G H I J K L Weight, kg 70 1250 2637 570 150 1000 1800 2640 319 161 419 3070 2379 Clear space for inspection Division into sections for transport within the site A D+45 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 70: A = 900 kg, D = 579 kg. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 70: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 32 A Rated data per fan GOLD 70: 3 x 400 V, 50 Hz, 6.5 kW (3.7 kW)* two parallel fans *) The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 71 GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 80 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 90 95 Supply air fan 2 1 L w,tot 80dB 85 90 95 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 80 3600 1,00 Max. airflow m3 /h m3 /s 29520 8,20 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -14 -16 -3 -6 -11 -19 -22 -30 -27 -29 -31 -38 -37 -43 -36 To the AHU surroundings** 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * Includes the integral attenuation of filters and the rotary heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 72 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD RX, rotary heat exchanger, size 80 Delivery and transport within the site The GOLD RX 80 is always supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section where the fan is located in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel. Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward Upward Forward Installation/duct connection options Forward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 76 76 Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. The unit has provision for fitting the adjustable support feet. Size A B D E F G H I J K L Weight, kg 80 1250 2637 570 150 1000 1800 2640 319 161 419 3070 2379 Clear space for inspection Division into sections for transport within the site A D+45 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 80: A = 900 kg, D = 579 kg. We reserve the right to alter specifications. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 80: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 50 A Rated data per fan GOLD 80: 3 x 400 V, 50 Hz, 6.5 kW, two parallel fans 20090415 www.swegon.com 73 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 04 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program.. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 Supply air fan 2 1 L w,tot 75dB 80 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 04 288 0,08 Max. airflow m3 /h m3 /s 1870 0,52 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 0 -10 -12 -5 -4 -11 -13 -8 -10 0 -5 -6 -13 -16 -25 To the inlet duct* 1 2 -5 -2 -10 -17 -4 -10 -15 -19 -28 -30 -28 -33 -32 -40 -45 -46 To the AHU surroundings** 1 2 -14 -24 -35 -32 -11 -19 -27 -34 -41 -43 -33 -38 -40 -47 -47 -56 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 74 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 04 Delivery and transport within the site The GOLD PX 04 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Right-hand version Stand/Base The GOLD PX 04 is supplied on a base frame with integrated openings for the forks of a fork-lift truck. The stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 180 28 28 28 32 50 50 80 80 Size A B C D E F G H I L Ø Weight, kg 04 800 820 236 345 239 268 385 920 267 2000 315 355 Clear space for inspection A clear space of 1,000 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 04: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A The air handling unit is internally wired for a single-phase, 230 V supply. Therefore ensure a correct neutral connection when connecting to a 3phase, 400 V power suppl Rated data per fan GOLD 04: 3 x 230 V, 50 Hz, 1.1 kW (0.55 kW)* *The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 75 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 05 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa 4 Extract air fan 2 3 1 L w,tot 75dB 80 4 85 90 Supply air fan 2 3 1 L w,tot 75dB 80 85 90 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 05 288 0,08 Max. airflow m3 /h m3 /s 2450 0,68 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 3 4 -3 -10 -12 -5 -11 -10 0 -5 -4 11 -6 -5 -11 -14 -13 -10 -8 -5 -10 -7 0 -1 -5 -4 -6 -7 -13 -10 -16 -14 -25 -20 To the inlet duct* 1 2 3 4 -5 -9 -2 2 -10 -11 -4 -8 -17 -18 -10 -12 -15 -25 -19 -18 -28 -26 -30 -28 -28 -26 -33 -32 -32 -32 -40 -37 -45 -47 -46 -48 To the AHU surroundings** 1 2 3 4 -14 -16 -11 0 -24 -25 -19 -20 -35 -32 -33 -35 -27 -34 -28 -31 -41 -38 -43 -40 -33 -34 -38 -37 -40 -41 -47 -44 -47 -45 -56 -51 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 76 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 05 Delivery and transport within the site The GOLD PX 05 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Right-hand version Stand/Base The GOLD PX 05 is supplied on a base frame with integrated openings for the forks of a fork-lift truck. The stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 180 28 28 28 32 50 50 80 80 Size A B C D E F G H I L Ø Weight, kg 05 800 820 236 345 239 268 385 920 267 2000 315 355 Clear space for inspection A clear space of 1,000 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 05: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 16 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A The air handling unit is internally wired for a single-phase, 230 V supply. Therefore ensure a correct neutral connection when connecting to a 3phase, 400 V power supply. Rated data per fan GOLD 05: 3 x 230 V, 50 Hz, 1.1 kW We reserve the right to alter specifications. 20090415 www.swegon.com 77 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 08 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 85 Supply air fan 2 1 L w,tot 75dB 80 85 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 08 360 0,10 Max. airflow m3 /h m3 /s 3600 1,00 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 2 1 2 1 2 -4 -4 -6 -8 -10 -9 -12 -11 -11 -9 -15 -12 -27 -24 To the inlet duct* 1 2 -2 -2 -3 -9 -4 -10 -14 -15 -27 -30 -31 -31 -38 -36 -46 -34 To the AHU surroundings** 1 2 -10 -18 -29 -31 -9 -18 -31 -30 -45 -44 -44 -42 -49 -46 -58 -55 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 78 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 08 Delivery and transport within the site The GOLD PX 08 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Right-hand version Stand/Base The GOLD PX 08 is supplied on a base frame with integrated openings for the forks of a fork-lift truck. The stand is available as an accessory. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 180 28 28 28 32 50 50 80 80 Size A B C D E F G H I L Ø Weight, kg 08 915 990 274 440 276 293 500 1085 292 2230 400 455 Clear space for inspection A clear space of 1,000 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 08: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 20 A or 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A The air handling unit is internally wired for a single-phase, 230 V supply. Therefore ensure a correct neutral connection when connecting to a 3phase, 400 V power supply. Rated data per fan GOLD 08: 3 x 230 V, 50 Hz, 1.4 kW We reserve the right to alter specifications. 20090415 www.swegon.com 79 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 12 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan Will be available later! Supply air fan Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 12 720 0,20 Max. airflow m3 /h m3 /s 4680 1,40 Ljudväg Område i Oktavband, nr / medelfrekvens, Hz 1 2 3 4 5 6 Will be available later! diagram 7 8 63 125 250 500 1000 2000 4000 8000 Till utlopps- kanal 1 2 1 2 -4 -4 -6 -8 -10 -9 -12 -11 -11 -9 -15 -12 -27 -24 Till inlopps- kanal* 1 2 -2 -2 -3 -9 -4 -10 -14 -15 -27 -30 -31 -31 -38 -36 -46 -34 Till aggregatets omgivning** 1 2 -10 -18 -29 -31 -9 -18 -31 -30 -45 -44 -44 -42 -49 -46 -58 -55 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 80 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 12 Leverans och intransport The GOLD PX 12 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The GOLD PX 12 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Right-hand version The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Left-hand version Installation/duct connection options A: Specify right-hand or left-hand version when ordering! Outdoor air Supply air Extract air Exhaust air Connection to Power Supply K 16 J 50 50 K 52* E 52 E 52 50 J 50 80 D If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Size A B C D E F G H J K L Ø Weight, kg 12 655 1199 324 1200 397 324 647 1295 935 551 2510 500 617 Clear space for inspection Division into sections for transport within the site A D + 19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 14: A = 132 kg, D = 275 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 12: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10A Rated data per fan GOLD 12: Motor shaft power: 1.6 kW, motorized control: 3 x 400 V, 50 Hz 20090415 www.swegon.com 81 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 14 Airflow, m3/h SFP v 2.5 2.0 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 75dB 80 85 Supply air fan 2 1 L w,tot 75dB 80 85 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 14 720 0,20 Max. airflow m3 /h m3 /s 5040 1,40 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 1 -12 -14 -8 -9 -3 -5 -6 -6 -9 -8 -7 -9 -15 -19 To the inlet duct* 1 2 -8 -3 -14 -23 -5 -12 -14 -14 -31 -30 -31 -31 -38 -36 -31 -33 To the AHU surroundings** 1 2 -14 -26 -37 -10 -22 -32 -24 -26 -39 -39 -42 -41 -41 -43 -46 -50 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 82 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 14 Delivery and transport within the site The GOLD PX 14 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. Right-hand version The air handling unit is delivered on wooden beams. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! Left-hand version B: Specify when ordering whether the unit shall have an outdoor air intake from above and/or extract air discharge upward! Outdoor air Supply air Extract air Exhaust air Connection to Power Supply M M E 28 E 50 50 28 80 D If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Size A B C D E F G H I J K L M Weight, kg 14 765 1295 1036 1200 400 400 1000 1295 252 122 146 2730 196 760 Clear space for inspection Division into sections for transport within the site A D + 19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 14: A = 235 kg, D = 290 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 14: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 14: 3 x 400 V, 50 Hz, 3.0 kW (1.2 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 83 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 20 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 Available total pressure rise, Pa 1.5 Extract air fan 2 1 L w,tot 75dB 80 85 90 Supply air fan 2 1 L w,tot 75dB 80 85 90 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 20 720 0,20 Max. airflow m3 /h m3 /s 6840 1,90 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 1 -12 -14 -8 -9 -3 -5 -6 -6 -9 -8 -7 -9 -15 -19 To the inlet duct* 1 2 -8 -3 -14 -23 -5 -12 -14 -14 -31 -30 -31 -31 -38 -36 -31 -33 To the AHU surroundings** 1 2 -14 -26 -37 -10 -22 -32 -24 -26 -39 -39 -42 -41 -41 -43 -46 -50 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 84 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 20 Delivery and transport within the site The GOLD PX 20 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Right-hand version The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Installation/duct connection options A: Specify right-hand or left-hand version when ordering! Left-hand version B: Specify when ordering whether the unit shall have an outdoor air intake from above and/or extract air discharge upward! Outdoor air Supply air Extract air Exhaust air Connection to Power Supply M M E 28 E 50 50 28 80 D If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Size A B C D E F G H I J K L M Weight, kg 20 765 1295 1036 1200 400 400 1000 1295 252 122 146 2730 196 760 Clear space for inspection Division into sections for transport within the site A D + 19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 20: A = 235 kg, D = 290 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 20: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 20: 3 x 400 V, 50 Hz, 3.0 kW 20090415 www.swegon.com 85 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 25 Airflow, m3/h 2.5 SFP v 2.0 1.5 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 Supply air fan 2 1 L w,tot 80dB 85 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 Size Min. airflow m3 /h m3 /s Max. airflow m3 /h m3 /s To the outlet duct 1 2 -8 1 -7 -6 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 GOLD 25 1080 9360 To the inlet duct* 1 2 -10 -14 -14 -5 -9 -14 -19 -27 -28 -30 -28 -32 -33 -33 -33 -32 To the AHU surroundings** 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 0,30 2,60 -15 -6 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 86 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 25 Delivery and transport within the site The GOLD PX 25 is always supplied as two units. The one unit consists of a centre section with heat exchanger and fan/filter section to the right of the centre section (viewed from the inspection side). The other unit consists of a fan/filter section to the left of the centre section (viewed from the inspection side). The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Right-hand version Left-hand version Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: Specify when ordering whether the unit shall have an outdoor air intake from above and/or extract air discharge upward! Outdoor air Supply air Extract air Exhaust air Connection to Power Supply M M E 28 E 50 50 28 80 D If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Size A B C D E F G H I J K L M Weight, kg 25 835 1595 1336 1500 550 500 1200 1595 300 148 194 3170 180 1020 Clear space for inspection Division into sections for transport within the site A D + 19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 25: A = 310 kg, D = 400 kg. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 25: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 25: 3 x 400 V, 50 Hz, 4.6 kW (2.3 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 87 GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 30 Airflow, m3/h SFP v 2.5 2.0 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 1.5 Available total pressure rise, Pa Extract air fan 2 1 L w,tot 80dB 85 90 Supply air fan 2 1 L w,tot 80dB 85 90 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 30 1080 0,30 Max. airflow m3 /h m3 /s 12240 3,40 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -8 1 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 To the inlet duct* 1 2 -10 -14 -14 -19 -5 -9 -14 -27 -28 -30 -28 -32 -33 -33 -33 -32 To the AHU surroundings** 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 -15 -6 -7 -6 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 88 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD PX, plate heat exchanger, size 30 Delivery and transport within the site The GOLD PX 30 is always supplied as two units. The one unit consists of a centre section with heat exchanger and fan/filter section to the right of the centre section (viewed from the inspection side). The other unit consists of a fan/filter section to the left of the centre section (viewed from the inspection side). The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. The electrical equipment cubicle and the drain pipe at the front of the air handling unit can be dismantled, if required, for transporting the unit within the building site. Right-hand version Left-hand version Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: Specify when ordering whether the unit shall have an outdoor air intake from above and/or extract air discharge upward! Outdoor air Supply air Extract air Exhaust air Connection to Power Supply M M E 28 E 50 50 28 80 D If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Size A B C D E F G H I J K L M Weight, kg 30 835 1595 1336 1500 550 500 1200 1595 300 148 194 3170 180 1020 Clear space for inspection Division into sections for transport within the site A D + 19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 30: A = 310 kg, D = 400 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit and at least 200 mm must be provided above the junction hood. Connection to Power Supply GOLD 30: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 20 A Rated data per fan GOLD 30: 3 x 400 V, 50 Hz, 4.6 kW 20090415 www.swegon.com 89 GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 35 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan The pressure drop in the chart does not include that of a droplet eliminator, if fitted. 2 1 L w,tot 75dB 80 85 90 Supply air fan 2 1 L w,tot 75dB 80 85 90 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 35 2160 0,60 Max. airflow m3 /h m3 /s 12240 3,40 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -6 1 -7 -5 -6 -4 -5 -5 -7 -8 -7 -12 -20 -25 To the inlet duct* 1 2 -10 -16 -15 -1 -3 -13 -21 -28 -31 -29 -29 -32 -38 -37 -43 -36 To the AHU surroundings** 1 2 -17 -29 -30 -10 -23 -28 -27 -25 -38 -38 -40 -41 -41 -46 -51 -56 -15 -9 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 90 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 35 Delivery and transport within the site The GOLD CX 35 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The air handling unit is delivered on wooden beams. The coil heat exchanger system is filled with liquid from the factory. Forward Installation/duct connection options Forward Upward Upward Forward Fan arrangement 2 Fan arrangement 1 Right-hand version Upward Upward Forward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 50 50 250 M If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Size A B C D E F G H I J K L M Weight, kg 35 875 1885 1626 680 125 600 1400 1885 300 192 242 2430 600 1450 Clear space for inspection Division into sections for transport within the site A D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 35: A = 405 kg, D = 640 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit. Connection to Power Supply GOLD 35: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 20 A Rated data per fan GOLD 35: 3 x 400 V, 50 Hz, 6.5 kW (3.1 kW)* * The frequency inverter restricts the output power to the values specified. 20090415 www.swegon.com 91 GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 40 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 L w,tot The pressure drop in the chart does not include that of a droplet eliminator, if fitted. 1 75dB 80 85 90 95 Supply air fan 2 L w,tot 1 75dB 80 85 90 95 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 40 2160 0,60 Max. airflow m3 /h m3 /s 15840 4,40 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -6 1 -7 -5 -6 -4 -5 -5 -7 -8 -7 -12 -20 -25 To the inlet duct* 1 2 -10 -16 -15 -1 -3 -13 -21 -28 -31 -29 -29 -32 -38 -37 -43 -36 To the AHU surroundings** 1 2 -17 -29 -30 -10 -23 -28 -27 -25 -38 -38 -40 -41 -41 -46 -51 -56 -15 -9 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 92 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 40 Delivery and transport within the site The GOLD CX 40 is always supplied as one complete unit. The air handling unit can be split into three sections to facilitate transporting it within the building site. Upward Forward The three sections are joined together by bolts and the electrical and control cables have quick connectors. Upward Forward Fan arrangement 2 Fan arrangement 1 The air handling unit is delivered on wooden beams. Right-hand version The coil heat exchanger system is filled with liquid from the factory. Upward Upward Forward Installation/duct connection options Forward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! Fan arrangement 1 C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 50 50 250 M If a water trap (accessory) is fitted, the air handling unit must be raised at least 50 mm to provide space for the water trap. Support feet (accessories) can be used for this purpose. Applicable to the right-hand version, fan arrangement 2 and the left-hand version, fan arrangement 1. Size A B C D E F G H I J K L M Weight, kg 40 875 1885 1626 680 125 600 1400 1885 300 192 242 2430 600 1450 Clear space for inspection Division into sections for transport within the site A D+19 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 40: A = 405 kg, D = 640 kg. We reserve the right to alter specifications. A clear space of 900 mm must be provided in front of the unit. Connection to Power Supply GOLD 40: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 32 A Rated data per fan GOLD 40: 3 x 400 V, 50 Hz, 6.5 kW 20090415 www.swegon.com 93 GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 50 Airflow, m3/h 2.5 SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.0 1.5 Available total pressure rise, Pa Extract air fan The pressure drop in the chart does not include that of a droplet eliminator, if fitted. 2 1 L w,tot 80dB 85 90 Supply air fan 2 1 L w,tot 80dB 85 90 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 50 2880 0,80 Max. airflow m3 /h m3 /s 18000 5,00 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -12 -17 -12 -5 -8 -9 -7 -7 -6 -6 -6 -7 -7 -11 -21 -23 To the inlet duct* 1 2 -16 -18 -14 -6 -8 -11 -12 -19 -31 -28 -26 -27 -38 -37 -43 -36 To the AHU surroundings** 1 2 -23 -31 -35 -16 -22 -32 -28 -28 -39 -39 -39 -40 -41 -45 -52 -54 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 94 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 50 Delivery and transport within the site The GOLD CX 50 is always supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section where the fan is located in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel. The coil heat exchanger system is filled with liquid from the factory. Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward Upward Forward Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 76 76 254 M Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. Applicable to the right-hand version, fan arrangement 2 and the left-hand version, fan arrangement 1: If a water trap is fitted, in addition to the base beams, the air handling unit must be raised at least 50 mm to provide space for the water trap. It is advisable to let these support feet remain on the unit. They can also be removed and adjustable support feet (accessories) can be installed. Size A B D E F G H I J K L M Weight, kg 50 1050 2318 760 150 800 1600 2253 423 115 360 2860 650 2237 Clear space for inspection Division into sections for transport within the site A D A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 50: A = 638 kg, D = 961 kg. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 50: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 25 A Rated data per fan GOLD 50: 3 x 400 V, 50 Hz, 4.6 kW (2.3 kW)* two parallel fans *) The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 95 GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 60 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan 2 The pressure drop in the chart does not include that of a droplet eliminator, if fitted. 1 L w,tot 80dB 85 90 95 Supply air fan 2 1 L w,tot 80dB 85 90 95 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 60 2880 0,80 Max. airflow m3 /h m3 /s 23400 6,50 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -12 -17 -12 -5 -8 -9 -7 -7 -6 -6 -6 -7 -7 -11 -21 -23 To the inlet duct* 1 2 -16 -18 -14 -6 -8 -11 -12 -19 -31 -28 -26 -27 -38 -37 -43 -36 To the AHU surroundings** 1 2 -23 -31 -35 -16 -22 -32 -28 -28 -39 -39 -39 -40 -41 -45 -52 -54 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 96 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 60 Delivery and transport within the site The GOLD CX 60 is always supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section where the fan is located in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel. The coil heat exchanger system is filled with liquid from the factory. Installation/duct connection options Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward Upward Forward A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Forward Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air Connection to Power Supply 28 28 76 76 254 M Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. Applicable to the right-hand version, fan arrangement 2 and the left-hand version, fan arrangement 1: If a water trap is fitted, in addition to the base beams, the air handling unit must be raised at least 50 mm to provide space for the water trap. It is advisable to let these support feet remain on the unit. They can also be removed and adjustable support feet (accessories) can be installed. Size A B D E F G H I J K L M Weight, kg 60 1050 2318 760 150 800 1600 2253 423 115 360 2860 650 2237 Clear space for inspection Division into sections for transport within the site A D A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 60: A = 638 kg, D = 961 kg. We reserve the right to alter specifications. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 60: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 40 A Rated data per fan GOLD 60: 3 x 400 V, 50 Hz, 4.6 kW, two parallel fans 20090415 www.swegon.com 97 GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 70 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan The pressure drop in the chart does not include that of a droplet eliminator, if fitted. 2 1 L w,tot 80dB 85 90 Supply air fan 2 1 L w,tot 80dB 85 90 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 70 3600 1,00 Max. airflow m3 /h m3 /s 25200 7,00 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -14 -16 -3 -6 -11 -19 -22 -30 -27 -29 -31 -38 -37 -43 -36 To the AHU surroundings** 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 98 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 70 Delivery and transport within the site The GOLD CX 70 is always supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section where the fan is located in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel. The coil heat exchanger system is filled with liquid from the factory. Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward Upward Forward Forward Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air 27 Connection to Power Supply 28 28 76 76 254 M Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. Applicable to the right-hand version, fan arrangement 2 and the left-hand version, fan arrangement 1: If a water trap is fitted, in addition to the base beams, the air handling unit must be raised at least 50 mm to provide space for the water trap. It is advisable to let these support feet remain on the unit. They can also be removed and adjustable support feet (accessories) can be installed. Size A B D E F G H I J K L M Weight, kg 70 1250 2637 760 150 1000 1800 2640 319 161 419 3260 800 3092 Clear space for inspection Division into sections for transport within the site A D+45 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 70: A = 900 kg, D = 1292 kg. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 70: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 32 A. Rated data per fan GOLD 70: 3 x 400 V, 50 Hz, 6.5 kW (3.7 kW)* two parallel fans *) The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 99 GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 80 Airflow, m3/h SFP v The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. 2.5 2.0 1.5 Available total pressure rise, Pa Extract air fan The pressure drop in the chart does not include that of a droplet eliminator, if fitted. 2 1 L w,tot 80dB 85 90 95 Supply air fan 2 1 L w,tot 80dB 85 90 95 Airflow, m3/s Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Correction factors KOK , dB Sound path Size Min. airflow m3 /h m3 /s GOLD 80 3600 1,00 Max. airflow m3 /h m3 /s 32400 9,00 Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -14 -16 -3 -6 -11 -19 -22 -30 -27 -29 -31 -38 -37 -43 -36 To the AHU surroundings** 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * Includes the integral attenuation of filters and the plate heat exchanger. ** The total sound power level emitted to the surroundings is the sum of the supply air and extract air sound levels. 100 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD CX, coil heat exchanger, size 80 Delivery and transport within the site The GOLD CX 80 is always supplied as two units. The one unit consists of the centre section with heat exchanger and fan/filter section where the fan is located in the upper level. The other unit consists of a fan/filter section where the fan is located in the lower level. The air handling unit can be split into three sections to facilitate transporting it within the building site. The three sections are joined together by bolts and the electrical and control cables have quick connectors. The unit is delivered on 100 mm high support feet made of steel. The coil heat exchanger system is filled with liquid from the factory. Upward Upward Forward Forward Fan arrangement 1 Fan arrangement 2 Right-hand version Upward Upward Forward Forward Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The arrangement of the functional sections can be vertically reversed. Specify this by selecting fan arrangement 1 or 2 when ordering! C: The fan outlet at the top of the air handling unit is covered by a cover panel. This cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for discharging air both forward and upward. Fan arrangement 1 Fan arrangement 2 Left-hand version Outdoor air Supply air Extract air Exhaust air 27 Connection to Power Supply 28 28 76 76 254 M Supplied on 100 mm high support feet. They can be removed or kept as they are when the unit is in place. Applicable to the right-hand version, fan arrangement 2 and the left-hand version, fan arrangement 1: If a water trap is fitted, in addition to the base beams, the air handling unit must be raised at least 50 mm to provide space for the water trap. It is advisable to let these support feet remain on the unit. They can also be removed and adjustable support feet (accessories) can be installed. Size A B D E F G H I J K L M Weight, kg 80 1250 2637 760 150 1000 1800 2640 319 161 419 3260 800 3092 Clear space for inspection Division into sections for transport within the site A D+45 mm A The unit can be divided into three sections at the building site. Dimensions: See A and D in the table above. Weight, size 80: A = 900 kg, D = 1292 kg. We reserve the right to alter specifications. A clear space of 1,100 mm must be provided in front of the unit. Connection to Power Supply GOLD 80: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 50 A Rated data per fan GOLD 80: 3 x 400 V, 50 Hz, 6.5 kW, two parallel fans 20090415 www.swegon.com 101 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 04 Airflow, m3/h Total pressure rise, Pa 85 L w,tot 2 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Fan 1 SFPv=1,25 1,00 0,75 70dB 75 80 Total pressure loss, Pa L w,tot F7 F5 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 04 288 0,08 Max. airflow m3 /h m3 /s 1870 0,52 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -3 0 -10 -12 -5 -4 -11 -13 -8 -10 0 -5 -6 -13 -16 -25 To the inlet duct* 1 2 -5 -2 -9 -3 -8 -12 -16 -18 -11 -16 -12 -20 -32 -33 To the AHU surroundings 1 2 -14 -24 -35 -32 -11 -19 -27 -34 -41 -43 -33 -38 -40 -47 -47 -56 -10 -3 * The integral attenuation of filters is not included. 102 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 04 Delivery and transport within the site The GOLD SD 04 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. Filter holders are available for pleated filters. Set of filters with pleated medium, pressure sensor, hoses and communication cable are optional extras. The air handling unit can be upended or turned upside down. The unit can also be installed with the inspection door upward, but not downward. Horizontal GOLD units can be installed outdoors if they are equipped with the roof, air intake section and exhaust air hood accessories. Stand/Base The air handling unit must be mounted on a stand (accessory) or some other form of base support, so that its inspection doors can be opened. Connection to Power Supply L B E 12 16 A D H F 16 C 12 D Ø Ø Size L B H A C D E F Ø Weight, kg 04 1100 820 490 948 152 245 236 410 315 115 Clear space for inspection A clear space of 1,100 mm should be provided in front of the unit. Connection to Power Supply GOLD 04: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 04: 3 x 230 V, 50 Hz, 1.1 kW (0.55 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 103 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 05 Total pressure rise, Pa Airflow, m3/h 2 4 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Fan 1 3 SF Pv= 70dB 75 80 85 5 1,0 0 90 Total pressure loss, Pa L w,tot 0,75 1,2 F7 F5 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 05 288 0,08 Max. airflow m3 /h m3 /s 2450 0,68 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 3 4 -3 -10 -12 -5 -11 -10 0 -5 -4 11 -6 -5 -11 -14 -13 -10 -8 -5 -10 -7 0 -1 -5 -4 -6 -7 -13 -10 -16 -14 -25 -20 To the inlet duct* 1 2 3 4 -5 -9 -2 2 -9 -10 -10 -11 -3 -3 -7 -5 -8 -18 -12 -11 -16 -14 -18 -16 -11 -9 -16 -15 -12 -12 -20 -17 -32 -34 -33 -35 To the AHU surroundings 1 2 3 4 -14 -16 -11 0 -24 -25 -19 -20 -35 -32 -33 -35 -27 -34 -28 -31 -41 -38 -43 -40 -33 -34 -38 -37 -40 -41 -47 -44 -47 -45 -56 -51 * The integral attenuation of filters is not included. 104 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 05 Delivery and transport within the site The GOLD SD 05 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. Filter holders are available for pleated filters. Set of filters with pleated medium, pressure sensor, hoses and communication cable are optional extras. The air handling unit can be upended or turned upside down. The unit can also be installed with the inspection door upward, but not downward. Horizontal GOLD units can be installed outdoors if they are equipped with the roof, air intake section and exhaust air hood accessories. Stand/Base The air handling unit must be mounted on a stand (accessory) or some other form of base support, so that its inspection doors can be opened. Connection to Power Supply L B E 12 16 A D H F 16 C 12 D Ø Ø Size L B H A C D E F Ø Weight, kg 05 1100 820 490 948 152 245 236 410 315 115 Clear space for inspection A clear space of 1,100 mm should be provided in front of the unit. Connection to Power Supply GOLD 05: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 05: 3 x 230 V, 50 Hz, 1.1 kW We reserve the right to alter specifications. 20090415 www.swegon.com 105 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 08 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan 2 1 SFP v=1 ,25 1,0 75dB 80 85 0,75 90 Total pressure loss, Pa L w,tot 0 F7 F5 Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 08 360 0,10 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 Max. airflow m3 /h m3 /s To the outlet duct 1 2 1 2 -4 -4 -6 -8 -10 -9 -12 -11 -11 -9 -15 -12 -27 -24 3780 To the inlet duct* 1 2 -2 -2 -2 -3 -2 -3 -7 -8 -15 -18 -14 -14 -18 -16 -33 -21 To the AHU surroundings 1 2 -10 -18 -29 -31 -9 -18 -31 -30 -45 -44 -44 -42 -49 -46 -58 -55 1,05 * The integral attenuation of filters is not included. 106 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 08 Delivery and transport within the site The GOLD SD 08 is produced in one single variant. All of its components are arranged at their given physical location inside the air handling unit. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. Filter holders are available for pleated filters. Set of filters with pleated medium, pressure sensor, hoses and communication cable are optional extras. The air handling unit can be upended or turned upside down. The unit can also be installed with the inspection door upward, but not downward. Horizontal GOLD units can be installed outdoors if they are equipped with the roof, air intake section and exhaust air hood accessories. Stand/Base The air handling unit must be mounted on a stand (accessory) or some other form of base support so that the inspection doors can be opened. Connection to Power Supply L B E 12 16 A D H F 16 C 12 D Ø Ø Size L B H A C D E F Ø Weight, kg 08 1175 990 575 1023 152 288 321 495 400 150 Clear space for inspection A clear space of 1,100 mm should be provided in front of the unit. Connection to Power Supply GOLD 08: 1-phase, 3-wire, 230 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 08: 3 x 230 V, 50 Hz, 1.4 kW We reserve the right to alter specifications. 20090415 www.swegon.com 107 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 14 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan L w,tot 85 1,25 SFPv= 2 1,0 0 0,75 1 70dB Total pressure loss, Pa L w,tot 80 75 il Co he at h e xc an ge r F7 Droplet elimina tor Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 14 720 0,20 Max. airflow m3 /h m3 /s 5760 1,60 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -8 1 -15 -6 -7 -6 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 To the inlet duct* 1 2 -10 -13 -5 -8 -7 -7 -12 -20 -16 -18 -11 -15 -13 -13 -20 -19 To the AHU surroundings 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 * The integral attenuation of filters and coil heat exchangers are not included. 108 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 14 Right-hand version Delivery and transport within the site The size 14 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The air handling unit is delivered on wooden beams. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 Fan B G I Fan + Filter Fan + Filter + Coil heat exchanger L2 L1 12 21 21 F F H Size J 100 A E C D 21 J 45 L3 E 100 21 14 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 230 340 475 28 Size L1 L2 L3 B H A C D E F G I J 14 1040 1909 2505 1295 756 1146 1012 619 919 400 1000 146 178 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 14: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 14: 3 x 400 V, 50 Hz, 3.0 kW (1.2 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 109 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 20 Total pressure rise, Pa Airflow, m3/h 1 2 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Fan SFPv =1,2 5 1,0 0 0,7 5 70dB 75 Total pressure loss, Pa L w,tot 80 Co il h 85 t ea ex c n ha ge r F7 Droplet e liminator Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 20 720 0,20 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 Max. airflow m3 /h m3 /s To the outlet duct 1 2 -8 1 -15 -6 -7 -6 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 9000 To the inlet duct* 1 2 -10 -13 -5 -8 -7 -7 -12 -20 -16 -18 -11 -15 -13 -13 -20 -19 To the AHU surroundings 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 2,50 * The integral attenuation of filters and coil heat exchangers are not included. 110 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 20 Right-hand version Delivery and transport within the site The size 20 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The air handling unit is delivered on wooden beams. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 Fan Fan + Filter B G I Fan + Filter + Coil heat exchanger L2 L1 12 21 21 F E C D 21 J F H Size J 100 45 L3 E 100 21 A 28 20 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 230 340 475 Size L1 L2 L3 B H A C D E F G I J 20 1040 1909 2505 1295 756 1146 1012 619 919 400 1000 146 178 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 20: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 20: 3 x 400 V, 50 Hz, 3.0 kW We reserve the right to alter specifications. 20090415 www.swegon.com 111 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 25 Airflow, m3/h Total pressure rise, Pa L w,tot 90dB 2 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Fan SFPv=1,25 1,0 0 1 75dB Total pressure loss, Pa L w,tot 0,75 80 85 l he C oi xc at e han ger F7 Droplet elimina tor Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s Max. airflow m3 /h m3 /s GOLD 25 1080 9720 0,30 2,70 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -8 1 -15 -6 -7 -6 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 To the inlet duct* 1 2 -10 -13 -5 -8 -7 -7 -12 -20 -16 -18 -11 -15 -13 -13 -20 -19 To the AHU surroundings 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 * The integral attenuation of filters and coil heat exchangers are not included. 112 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 25 Right-hand version Delivery and transport within the site The size 25 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The air handling unit is delivered on wooden beams. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 Fan B G I Fan + Filter Fan + Filter + Coil heat exchanger L2 L1 12 21 21 F E C D 21 J F H Size J 100 45 L3 E 100 21 A 28 25 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 310 450 670 Size L1 L2 L3 B H A C D E F G I J 25 1145 2014 2610 1595 1446 1336 1117 619 919 500 1200 194 263 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 25: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 25: 3 x 400 V, 50 Hz, 4.6 kW (2.3 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 113 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 30 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan 2 1 SFPv= 1,25 1,00 95 0,75 75dB 80 Total pressure loss, Pa L w,tot 85 90 Co e il h at ex a ch ng er F7 Droplet elimina tor Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 30 1080 0,30 Max. airflow m3 /h m3 /s 13320 3,70 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -8 1 -15 -6 -7 -6 -7 -6 -6 -6 -7 -8 -7 -13 -22 -21 To the inlet duct* 1 2 -10 -13 -5 -8 -7 -7 -12 -20 -16 -18 -11 -15 -13 -13 -20 -19 To the AHU surroundings 1 2 -19 -29 -30 -28 -10 -20 -29 -27 -39 -39 -40 -41 -41 -47 -53 -52 * The integral attenuation of filters and coil heat exchangers are not included. 114 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 30 Right-hand version Delivery and transport within the site The size 30 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The air handling unit is delivered on wooden beams. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 Fan Fan + Filter B G I Fan + Filter + Coil heat exchanger L2 L1 12 21 21 F E C D 21 J F H Size J 100 45 L3 E 100 21 A 30 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 310 450 670 28 Size L1 L2 L3 B H A C D E F G I J 30 1145 2014 2610 1595 1026 1446 1117 619 919 500 1200 194 263 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 30: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 30: 3 x 400 V, 50 Hz, 4.6 kW We reserve the right to alter specifications. 20090415 www.swegon.com 115 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 35 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan 2 SFPv=1,25 1,0 0 0,75 1 75dB 80 Total pressure loss, Pa L w,tot 85 C h oil 90 ea te xc h an ge r F7 Droplet elimina tor Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 35 2160 0,60 Max. airflow m3 /h m3 /s 14040 3,90 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -13 -3 -5 -9 -4 -12 -15 -18 -15 -12 -14 -18 -17 -30 -23 To the AHU surroundings 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * The integral attenuation of filters and coil heat exchangers are not included. 116 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 35 Right-hand version Delivery and transport within the site The size 35 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The air handling unit is delivered on wooden beams. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 Fan Fan + Filter B G I Fan + Filter + Coil heat exchanger L2 L1 12 21 21 F E C D 21 J F H Size J 100 45 L3 E 100 21 A 28 35 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 365 520 760 Size L1 L2 L3 B H A C D E F G I J 35 1145 2014 2610 1885 1026 1736 1117 619 919 600 1400 242 213 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 35: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 10 A Rated data per fan GOLD 35: 3 x 400 V, 50 Hz, 6.5 kW (3.1 kW)* * The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 117 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 40 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan 1 2 SFP v=1 ,25 0 1,0 85 Total pressure loss, Pa 80 90 C l oi he 5 75dB 0,7 L w,tot at c ex ha ng 95 er F7 Droplet elim inator Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 40 2160 0,60 Max. airflow m3 /h m3 /s 18000 5,00 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -13 -3 -5 -9 -4 -12 -15 -18 -15 -12 -14 -18 -17 -30 -23 To the AHU surroundings 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * The integral attenuation of filters and coil heat exchangers are not included. 118 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 40 Right-hand version Delivery and transport within the site The size 40 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The air handling unit is delivered on wooden beams. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Installation/duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 Fan Fan + Filter B G I Fan + Filter + Coil heat exchanger L2 L1 12 21 21 F E C D 21 J F H Size J 100 45 L3 E 100 21 A 40 28 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 365 520 760 Size L1 L2 L3 B H A C D E F G I J 40 1145 2014 2610 1885 1026 1736 1117 619 919 600 1400 242 213 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 40: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 40: 3 x 400 V, 50 Hz, 6.5 kW We reserve the right to alter specifications. 20090415 www.swegon.com 119 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 50 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan 2 SFPv=1,25 1,00 0,75 1 80dB Total pressure loss, Pa L w,tot 85 90 lh C oi ex ea t cha nge r F7 Droplet elimina tor Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 50 2880 0,80 Max. airflow m3 /h m3 /s 19440 5,40 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -12 -17 -12 -5 -8 -9 -7 -7 -6 -6 -6 -7 -7 -11 -21 -23 To the inlet duct* 1 2 -16 -17 -6 -7 -7 -4 -5 -12 -19 -16 -9 -10 -18 -17 -30 -23 To the AHU surroundings 1 2 -23 -31 -35 -16 -22 -32 -28 -28 -39 -39 -39 -40 -41 -45 -52 -54 * The integral attenuation of filters and coil heat exchangers are not included. 120 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 50 Right-hand version Delivery and transport within the site The GOLD SD 50 units are available in right-hand or lefthand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. Supplied on 100 m high support feet. Duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 100 Fan Fan + Filter B G I Fan + Filter + Coil heat exchanger L2 L1 12 21 21 E C D 21 J F H Size J 100 A L3 E 100 21 F 50 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 550 760 1170 28 Size L1 L2 L3 A B H C D E F G I J 50 1145 2014 2610 2165 2313 1320 1117 619 919 800 1600 355 260 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 50: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 50: 3 x 400 V, 50 Hz, 4.6 kW (2.3 kW)* two parallel fans *) The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 121 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 60 Total pressure rise, Pa Airflow, m3/h 1 2 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Fan SFP v=1, 25 1,00 0,7 80dB 85 Total pressure loss, Pa L w,tot 90 5 95 Co il a he te x a ch ng er F7 Droplet e liminator Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 60 2880 0,80 Max. airflow m3 /h m3 /s 26280 7,30 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -12 -17 -12 -5 -8 -9 -7 -7 -6 -6 -6 -7 -7 -11 -21 -23 To the inlet duct* 1 2 -16 -17 -6 -7 -7 -4 -5 -12 -19 -16 -9 -10 -18 -17 -30 -23 To the AHU surroundings 1 2 -23 -31 -35 -16 -22 -32 -28 -28 -39 -39 -39 -40 -41 -45 -52 -54 * The integral attenuation of filters and coil heat exchangers are not included. 122 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 60 Right-hand version Delivery and transport within the site The GOLD SD 60 units are available in right-hand or lefthand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The unit is always supplied as one unit. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. Supplied on 100 m high support feet. Duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Outdoor air Supply air Extract air Exhaust air Direction of airflow Connection to Power Supply L2 L1 12 21 21 F L3 E 100 21 E C C D 21 J F H J 100 28 28 100 Fan Fan + Filter B G I Fan + Filter + Coil heat exchanger L2 L1 12 21 21 E C D 21 J F H Size J 100 A L3 E 100 21 F 60 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 550 760 1170 28 Size L1 L2 L3 A B H C D E F G I J 60 1145 2014 2610 2165 2313 1320 1117 619 919 800 1600 355 260 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 60: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 20 A Rated data per fan GOLD 60: 3 x 400 V, 50 Hz, 4.6 kW, two parallel fans We reserve the right to alter specifications. 20090415 www.swegon.com 123 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 70 Airflow, m3/h The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Total pressure rise, Pa Fan L w,tot 95dB SFPv=1,25 2 1,00 0,75 1 80dB Total pressure loss, Pa L w,tot 85 90 C h oil ea te xc h an ge r F7 Droplet elim inator Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 70 3600 1,00 Max. airflow m3 /h m3 /s 28440 7,90 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -13 -3 -5 -9 -4 -12 -15 -18 -15 -12 -14 -18 -17 -30 -23 To the AHU surroundings 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * The integral attenuation of filters and coil heat exchangers are not included. 124 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 70 Right-hand version Delivery and transport within the site The GOLD SD 70 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The air handling units are supplied as one unit if they each consist of a fan or fan+filter. If the unit consists of a fan + filter + coil heat exchanger, it is supplied as two units. The one unit then consists of a fan + coil heat exchanger and the other unit consists of a filter. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The unit is supplied on 100 m high support feet made of steel. Duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. 12 L1 F 21 Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Outdoor air Supply air Extract air Exhaust air Direction of airflow L2 21 J L3 E 100 21 E C C D Connection to Power Supply 21 F H J 100 100 28 28 Fan Fan + Filter B G I 12 L1 F 21 Fan + Filter + Coil heat exchanger L2 21 J Size J 100 E C C D 21 F H A L3 E 100 21 70 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 675 945 1700 100 28 Size L1 L2 L3 A B H C D E F G I J 70 1278 2500 3260 2484 2637 1320 1250 760 1250 1000 1800 419 160 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 70: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 16 A Rated data per fan GOLD 70: 3 x 400 V, 50 Hz, 6.5 kW (3.7 kW)* two parallel fans *) The frequency inverter restricts the output power to the values specified. We reserve the right to alter specifications. 20090415 www.swegon.com 125 GOLD Sizing, Installation, Dimensions and Weights GOLD SD, size 80 Airflow, m3/h Total pressure rise, Pa 2 The charts and tables in this documentation are intended for use as a general survey. Exact sizing can be obtained in the ProUnit air handling unit selection program. Fan 1 SFP v=1, 25 1,00 80dB 85 Total pressure loss, Pa L w,tot 90 Co 0,75 95 il h t ea ex c n ha ge r F7 Droplet elimina tor Airflow, m3/s Correction factors KOK , dB Min. and max. airflows The flows specified refer to those that can be preset in the hand-held micro terminal. The effect of external pressure drop determines the feasible flow limits that can come into use. Size Min. airflow m3 /h m3 /s GOLD 80 3600 1,00 Max. airflow m3 /h m3 /s 36000 10,00 Sound path Range in chart Octave band, no. / mid-frequency, Hz 1 2 3 4 5 6 7 8 63 125 250 500 1000 2000 4000 8000 To the outlet duct 1 2 -10 -15 -12 -4 -9 -9 -7 -5 -5 -6 -6 -8 -10 -13 -24 -25 To the inlet duct* 1 2 -10 -13 -3 -5 -9 -4 -12 -15 -18 -15 -12 -14 -18 -17 -30 -23 To the AHU surroundings 1 2 -21 -29 -35 -15 -23 -32 -28 -26 -38 -39 -39 -41 -44 -47 -55 -56 * The integral attenuation of filters and coil heat exchangers are not included. 126 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Sizing, Installation, Dimensions and Weights Left-hand version GOLD SD, size 80 Right-hand version Delivery and transport within the site The GOLD SD 80 units are available in right-hand or left-hand version as a fan section, fan + filter or fan + filter + coil heat exchanger. The air handling units are supplied as one unit if they each consist of a fan or fan+filter. If the unit consists of a fan + filter + coil heat exchanger, it is supplied as two units. The one unit then consists of a fan + coil heat exchanger and the other unit consists of a filter. The air handling unit can be split at the building site to facilitate transporting it within the site. The sections are jointed together by means of bolts. The GOLD SD can be used as a supply air or an extract air handling unit. If both supply air and extract air handling units are used in a ventilation system, the supply air unit is fitted with a control unit and the extract air unit is without. A communication cable is used to connect them to one another making it possible to control both units. The unit is supplied on 100 m high support feet made of steel. Duct connection options A: Specify right-hand or left-hand version when ordering! B: The fan outlet at the top of the air handling unit is covered by a cover panel. At the building site, this cover panel can be easily moved to the end wall panel if it is desirable for the upper fan to discharge air upwards. The fan outlet can also be used for both forward and upward air discharge. 12 L1 F 21 Fan Fan + Filter Fan + Filter + Coil heat exchanger in extract air Droplet eliminator is optional. Fan + Filter + Coil heat exchanger in supply air Outdoor air Supply air Extract air Exhaust air Direction of airflow L2 21 J L3 E 100 21 E C C D Connection to Power Supply 21 F H J 100 100 28 28 Fan Fan + Filter B G I 12 L1 F 21 Fan + Filter + Coil heat exchanger L2 21 J L3 E 100 21 Size J 100 C D 21 F H A E C 28 80 28 Weight, kg Weight, kg Weight, kg fan fan+filter fan + filter + coil 675 945 1700 Size L1 L2 L3 A B H C D E F G I J 80 1278 2500 3260 2484 2637 1320 1250 760 1250 1000 1800 419 160 Clear space for inspection A clear space of 900 mm should be provided in front of the unit. Connection to Power Supply GOLD 80: 3-phase, 5-wire, 400 V -10/+15%, 50 Hz, 25 A Rated data per fan GOLD 80: 3 x 400 V, 50 Hz, 6.5 kW, two parallel fans We reserve the right to alter specifications. 20090415 www.swegon.com 127 100 GOLD 128 We reserve the right to alter specifications. 20090415 www.swegon.com