EM-600 Flush-Mount Boundary Microphone ø28 (ø1.1")
APPEARANCE AND DIMENSIONAL DIAGRAM
Top View
60 (2.35")
4 (0.16")
8 (0.31")
VP-1061/1121
VP-1241/1361
DESCRIPTION The TOA EM-600 has an unobtrusive design that allows simple flushmounting in walls, ceilings and desktops, making it particularly well-suited for conference room recording, as well as in security monitoring applications. An electret condenser microphone element’s omnidirectional pickup pattern ensures a high degree of sensitivity and a wide frequency range. The EM-600’s has been designed to minimize interference from low-frequency sounds that may degrade audio reproduction. It also incorporates two rubber isolation rings to resist vibrations that may adversely affect audio quality.
18.7 (0.74")
unit: mm
Bottom View
Rubber Isolation Ring (accessory)
9 – 40 (0.35" – 1.57")
M20 Nut (accessory)
FEATURES • Ideal for conference room recording and security monitoring. Recommended Installation diameter ø24 (ø0.94")
• Electret condenser microphone element with omnidirectional pattern for comprehensive pickup.
Mounting example
• Two rubber isolation rings are provided as an accessory serving to reduce vibration.
ø20 (ø0.79")
30 (1.18") ø23.5 (ø0.93") ø28 (ø1.1")
6 (0.24")
• A 50 Hz low-cut filter reduces intrusive noise, such as air conditioner rumble or door opening/closing.
5 (0.20")
• Optimized to deliver best performance when used on a desk or attached to a ceiling.
2 (0.08")
• Unobtrusive design allows easy flush-mounting in walls, ceilings, and desktops.
M20 Nut (accessory)
• Wide frequency range (30Hz – 20kHz) provides well-balanced sound with clarity and a satisfying tonal response. • Phantom power range of 9 to 52 volts enhances operational versatility.
Rubber Isolation Ring (accessory)
Power circuit
Filter circuit
Hot Cold 1
2
Shield 3
Circuit diagram
Body earth
TOA Corporation EM-600 1/2
SPECIFICATIONS Element Polar Pattern Rated Impedance Rated Sensitivity Phantom Power Frequency Response Output Connector Operating Temperature Finish
Electret condenser Omnidirectional 120 Ω, balanced –36 dB (1kHz 0 dB = 1V/Pa) 9 – 52 V DC 30 Hz – 20k Hz XLR-3-12 equivalent 0°C to +40°C (32°F to 104°F) Body: Steel, white, semi-gloss, paint Head: Zinc-plated steel wire, white, semi-gloss, paint ø28 × 68mm (ø1.1" × 2.68") 85g (0.19 lb) Rubber Isolation Ring × 2, M20 Nut × 1
Dimensions Weight Accessory
CHARACTERISTIC DIAGRAMS Frequency Response [dB] 20
Response
10
ARCHITECTURAL AND ENGINEERING SPECIFICATIONS The flush-mount boundary microphone shall be designed for sound pick-up applications, be 28 mm (1.1") in diameter, and have an omnidirectional electret condenser microphone element. It shall be unobtrusively mountable into a ceiling, wall or desk. Frequency response shall be 30 Hz to 20k Hz. Rated impedance shall be 120 Ω, balanced, and rated sensitivity shall be –36 dB (1k Hz 0 dB=1 V/Pa). A 50 Hz low-cut filter shall reduce intrusive noise. The microphone shall be powered by any phantom power source supplying 9 – 52 volts. The output connector shall be XLR-3-12 equivalent. Operating temperature shall be 0° C to +40° C (32° F to 104° F). Body finish shall be steel, and head finish shall be zinc-plated steel wire, both with white semi-gloss paint. Dimensions shall be ø28 x 68 mm (ø1.1" × 2.68"), and weight shall be 85 g (0.19 lb). Two rubber isolation rings and an M20 nut shall be provided as accessories. The microphone shall provide clear and high-quality sound, and be well-suited for conference recording and security monitoring applications. The flush-mounted boundary microphone shall be TOA model EM-600.
–0 –10 –20 –30 20
50
100
500
1k
5k
Frequency
10k
20k [Hz]
Polar Response 330°
0° 5
30°
0 –5 –10
300°
60°
–15 –20
270°
90°
240°
120°
150°
210° 180°
1kHz 2kHz 4kHz 8kHz
TOA Corporation www.toa.jp TOA Corporation EM-600 2/2
Specifications are subject to change without notice. (1010) 833-62-504-3A u