GOLD Specifications Contents Air handling unit.............................................................................................................. 192 CoolDX cooling unit......................................................................................................... 197 Unit sections..................................................................................................................... 198 Duct accessories............................................................................................................... 198 Hoods................................................................................................................................ 205 Filters................................................................................................................................ 206 Outdoor installation........................................................................................................ 206 Extra Accessories.............................................................................................................. 208 We reserve the right to alter specifications. 20090415 www.swegon.com 191 GOLD Specification GOLD RX/PX/CX Air handling units, sizes 04-08 and 14-40: GOLD Size: Version: C Fan arrangement: Fan arr. 1 =1 Fan arr. 2 (sizes 14-40 only) =2 Fan arr. 3 (units with plate h. exch. only) =3 GOLD-aa-b-c-d-e-f 04, 05, 08, 14, 20, 25, 30, 35, 40 Type of heat exchanger: Rotary, standard Rotary, hygroscopic Rotary, epoxy-treated Plate (sizes 04-30 only) Coil, filled with liquid, without droplet eliminator (sizes 35-40 only) Coil, filled with liquid, with droplet eliminator (sizes 35-40 only) Coil, not filled, without droplet eliminator (sizes 35-40 only) Coil, not filled, with droplet eliminator (sizes 35-40 only) Plate, epoxy-treated (sizes 04-30 only) Voltage: 400 V (sizes 14-40 only) 230 V (sizes 04-08 only) =1 =2 =3 =4 =5 =6 =7 =8 =9 =1 =2 Version: Right-hand =1 Left-hand (units with plate and coil heat exchangers only, select the right-hand version for units with rotary heat exchanger, the unit can be converted to the left-hand version at the site) =2 Right-hand, outdoor air intake from above (applies to size 14–30 units) =3 Right-hand, extract air intake from above (applies to size 14–30 units) =4 Right-hand, outdoor air and extract air intake from above (applies to size 14–30 units with plate heat exchanger) = 5 Left-hand (outdoor air intake from above (applies to size 14–30 units with plate heat exchanger, select the right-hand version, extract air intake from above, for units with rotary heat exchanger, the unit can be converted to the left-hand version at the site) =6 Left-hand, extract air intake from above (applies to size 14–30 units with plate heat exchanger, select the right-hand version, outdoor air intake from above, for units with rotary heat exchanger, the unit can be converted to the left-hand version at the site) =7 Left-hand, outdoor air and extract air intake from above (applies to size 14–30 units with plate heat exchanger) =8 Water trap 192 We reserve the right to alter specifications. 20090415 Version: Plate heat exchanger Coil heat exchanger TBXZ-1-40-a =1 = 2 www.swegon.com GOLD Specification GOLD RX Air handling unit, size 12, rotary heat exchanger GOLD Size: Version: GOLD-aa-b-RX 12 D Configuration: Fan arrangement: Fan arrangement 1 Fan arrangement 2 Type of heat Standard exchanger: Hygroscopic Epoxy treated Right-hand Version: Left-hand Recirculation section: Utan Med GOLD RX Top Air handling unit, size 12, rotary heat exchanger GOLD Size: Version: GOLD-aa-b-RX-TOP 12 D Configuration: Type of heat Standard exchanger: Hygroscopic Epoxy treated Right-hand Version: Left-hand GOLD PX Air handling unit, size 12, plate heat exchanger GOLD Size: Version: GOLD-aa-b-PX 12 D Configuration: Type of heat Standard exchanger: Epoxy treated Version: Right-hand Left-hand We reserve the right to alter specifications. 20090415 www.swegon.com 193 GOLD Specification GOLD RX Air handling units, sizes 50-80, with rotary heat exchanger GOLD Size: Version: GOLD-aa-b-RX-2 50, 60, 70, 80 C Configuration: Fan arrangement: Fan arrangement 1 Fan arrangement 2 Standard Rotor surface finish: Hygroscopic Epoxy-coated Right-hand Version: Left-hand Without Air recircul. section: With Unit connections for cooling section or heating section: Without With GOLD CX Air handling units, sizes 50-80, coil heat exchanger GOLD Size: Version: GOLD-aa-b-CX-2 50, 60, 70, 80 C Configuration: Fan arrangement: Fan arrangement 1 Fan arrangement 2 Right-hand Version: Left-hand Without Air recircul. section: With 30% ethylene glycol Filled with: Not filled Unit connections for cooling section or heating section: Without With Droplet eliminator Without With Water trap For coil heat exchanger 194 We reserve the right to alter specifications. TBXZ-1-40-2 20090415 www.swegon.com GOLD Specification GOLD SD Air handling unit Sizes 04 – 08 Sizes 50-80 GOLD SD GOLD SD GOLD-aa-b-c-d-SD Size 04, 05, 08 Version C Size: Version: GOLD-aa-b-SD-2 50, 60, 70 ,80 C Configuration: Type of control equipment Incl. control unit =1 Excl. control unit =2 (for use when two units can be controlled from same control unit) Filter (pleated filter) Without F5 F7 =0 =1 =2 Sizes 14-40 GOLD SD Size: Version: GOLD-aa-b-SD 14, 20, 25, 30, 35, 40 Type of control equip. Incl. control unit Excl. control unit (for use when two units can be controlled from same control unit) Filter Without F7 Coil heat exchanger Without With, supply air AHU With, exhaust air AHU Droplet eliminator Without With Duct Coil Conn. fan outlet size (sizes 50-80 only) Version C Right-hand Left-hand Configuration: Type of control equipment Incl. control unit Excl. control unit (for use when two units can be controlled from same control unit) Filter Without F7 Coil heat exchanger Without With, supply air AHU With, exhaust air AHU Droplet eliminator Without With Duct Coil Conn. fan outlet size (sizes 50-80 only) Version Pipework package for the GOLD SD For unit size 14, 20 25, 30 35, 40 50, 60 70, 80 Right-hand Left-hand = 20 = 30 = 40 = 60 = 80 Floor stand for pipework package GOLD SD Water trap For coil heat exchanger GOLD SD 14-60 GOLD SD 70-80 TBXZ-1-40-a =1 =2 We reserve the right to alter specifications. 20090415 For unit size 14, 20 25-80 TBXZ-1-42-aa TBXZ-1-43-a =1 =2 www.swegon.com 195 GOLD Specification Replacement material Set of filters, bag For one airflow direction For unit size: 04, 05 08 14, 20 25, 30 35, 40 50, 60 70, 80 = 05 = 08 = 20 = 30 = 40 = 60 = 80 Filter class: F7 =7 TBFZ-2-01-aa-b Set of filters, prefilters For one airflow direction. Set of filters, pleated filter, 300 mm TBFZ-1-03-aa-b For one airflow direction, to GOLD PX 14-30, air inlet from above. For unit size: 14, 20 = 20 25, 30 = 30 Filter class: F7 =7 Set of filters, pleated filter, GOLD SD 04-08 For one airflow direction TBFZ-1-05-aa-b For unit size: 04, 05 08 = 05 = 08 Filter class: F5 F7 = 5 =7 Set of filters, pleated filter, GOLD SD 14-80 For one airflow direction TBFZ-1-08-aaa-aaa-b Connection size: Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600  1600x800  1800x1000 = 000-031 = 000-040 = 000-050 = 100-040 = 120-050 = 140-060 = 160-080 = 180-100 Filter type: Aluminium Compact =1 =2 Set of filters, carbon filters For one airflow direction. Size 17 24 36 50 72 98 TBFZ-1-09 TBFZ-1-11-aaa = 017 = 024 = 036 = 050 = 072 = 098 TBFZ-1-06-aa-b For unit size: 14, 20 25, 30 35, 40 50, 60 70, 80 = 20 = 30 = 40 = 60 = 80 Filter class: F7 =7 196 Set of filters, pleated filters, GOLD RX Top For one airflow direction, size 12 We reserve the right to alter specifications. 20090415 www.swegon.com GOLD Specification Cooling units CoolDX cooling unit COOLDX-aa-b-c-d-e Cool DXS cooling unit COOLDXS-aa-b-c-d-e-1 For GOLD, size: 08 = 08 12 = 12 14/20 = 20 25/30 = 30 35/40 = 40 50/60 = 60 For GOLD, size: 12 14/20 25/30 35/40 50/60 70/80 = 12 = 20 = 30 = 40 = 60 = 80 Version A: =A Capacity variant 1 2 =1 =2 Inspection side Right-hand Left-hand =1 =2 Version A: Capacity variant 1 2 3 (not size 08 and 12) =A = 1 = 2 =3 Position of cooling coil Top = 1 Bottom =2 Inspection side Right-hand = 1 Left-hand =2 Droplet collector Without With =0 =1 Size 08 is only available according to the following codes: COOLDX-08-A-c-2-1 COOLDX-08-A-c-1-2 Accessories Base for the CoolDX For CoolDX, size 08 TBLZ-1-44 Base for the CoolDX TBFZ-1-02-aa-b For unit size: 08 = 08 12 = 12 20 = 20 30 = 30 40 = 40 60 = 60 Filter class: F7 =7 Water trap TBXZ-1-40-3 For CoolDX We reserve the right to alter specifications. 20090415 www.swegon.com 197 GOLD Specification Duct accessories Unit sections Air recirculation section For recirculated air TBBR-1-aa-b-c Damper Damper with motor Tightness class 3 Unit size: 14, 20 25, 30 35, 40 Fan arrangement: For GOLD units with rot. heat + coil heat exch., fan arrangement 1 and plate heat exch., fan arrangement 3 with supply air at bottom right (viewed from the inspection side). = 1 For GOLD units with rot. heat + coil heat exch., fan arrangement 2 and plate heat exch., fan arrangement 3 with supply air at bottom left (viewed from the inspection side). = 2 Version: Right-hand Left-hand = 20 = 30 = 40 Version: Version 1* = 1 Version 2** = 2 =1 =2 Air recirculation section For recirculated air, GOLD RX/PX size 12. TCBR-1-12 Configuration: Fan arrangement 1 2 Version: Right-hand Left-hand Duct connection dimensions: Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600  1600x800  1800x1000 Damper blades: Uninsulated Insulated (rectangular dampers only) Damper motor: With spring return =1 On/off = 2 Modulating with spring return = 3 (Applicable to rectangular damper and 500 mm dia. only) =1 =2 ** Duct connection dimensions: 100-040, 180-100 Weather protection for damper actuator TBLZ-1-45 Silencer 20090415 TBDA-1-aaa-aaa-bbb Duct connection dimensions: Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600  1600x800  1800x1000 Length: 900 mm. 1,200 mm. 1,200 mm. 650 mm. 650 mm. 650 mm. 650 mm. 1,250 mm. We reserve the right to alter specifications. = 000-031 = 000-040 = 000-050 = 100-040 = 120-050 = 140-060 = 160-080 = 180-100 * Duct connection dimensions: 000-031, 000-040, 000-050, 120-050, 140-060, 160-080 Unit-silencer 198 TBSA-X-aaa-aaa-b-c For silencer: Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600  1600x800  1800x1000 = 000-031 = 000-040 = 000-050 = 100-040 = 120-050 = 140-060 = 160-080 = 180-010 = 090 = 120 = 120 = 065 = 065 = 065 = 065 = 125 www.swegon.com GOLD Specification Air heater (coil) Air heater for hot water (size 05-12) Air heater for hot water (size 50-80) TBLA-5-aaa-aaa-b-c Connection dimensions: Ø 315 Ø 400 Ø 500 = 000-031 = 000-040 = 000-050 Version: Standard =2 Capacity variant: Capacity variant 1 = 1 (standard version) Capacity variant 2 =2 (Applicable to size 400 and 500 mm dia. only) Air heater for hot water (size 05-40) Connection dimensions: 1600x800 1800x1000 Configuration: Version: Casing only Water coil Capacity variant: Casing only Capacity variant 1 Capacity variant 2 Capacity variant 3 Connection side: Right-hand Left-hand TBLA-5-aaa-aaa = 160-080 = 180-100 TBLA-4-aaa-aaa-b-c Connection dimensions: Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600 Version: Thermoguard =1 (cap. variant 1 only) Standard = 2 (Applicable to sizes 1000x400-1400x600 only) Capacity variant: Capacity variant 1 = 1 (applicable to size Ø 500, standard version only) Capacity variant 2 =2 (applicable to size 1000x400-1400x600, standard version only) Capacity variant 3 =3 (applicable to size 1000x400-1400x600, standard version only) = 000-031 = 000-040 = 000-050 = 100-040 = 120-050 = 140-060 We reserve the right to alter specifications. 20090415 www.swegon.com 199 GOLD Specification Set of valves, heating TBVL-2-aaa 2(3)-way valve including actuator, cable and insertion sensor Not used for the Xzone control function. See the TBVA valve set. (If the liquid flow exceeds 2.5 l/s, pls. contact Swegon) Valve size: Kvs 0.25 Kvs 0.40 Kvs 0.63 Kvs 1.0 Kvs 1.6 Kvs 2.5 Kvs 4 Kvs 6.3 Kvs 10 Kvs 16 Kvs 25 = 002 = 004 = 006 = 010 = 016 = 025 = 040 = 063 = 100 = 160 = 250 Set of electrical connections: For water coil Cable, resistor and insertion sensor. Cable, resistor and snap-on sensor. TBLZ-1-27-a =1 =2 Circulation pump TBPA-3-aaa Set of pump components for the secondary side for heating coils without anti-frost protection, including non-return valve and adjustment valve. Capacity at max 25 kPa pressure drop in coil and pipework: < 0,09 l/s =009 0,091-0,17 l/s =017 0,171 - 0,35 l/s =035 0,351 - 0,6 l/s =060 0,601 - 1,0 l/s =100 Circulation pump TBPA-2-aaa Set of pump components for the secondary side for heating coils without anti-frost protection, including non-return valve and adjustment valve. Capacity at max 25 kPa pressure drop in coil and pipework: 1,01- 1,5 l/s =150 1,501 - 2,5 l/s =250 200 We reserve the right to alter specifications. Air heater for preheating, hot water TBLF-1-aaa-aaa Including control components, TBLZ-1-53-1 Connection size: Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600  1600x800  1800x1000 = 000-031 = 000-040 = 000-050 = 100-040 = 120-050 = 140-060 = 160-080 = 180-100 Valve set for cooling and heating TBVA-1-aaa 2(3)-way valve including actuator Also used for the Xzone control function with the TBLA air heater (The SEBG pipework package is recommended for liquid flows exceeding 5 l/s.) Valve size Kvs 0,25 Kvs 0,40 Kvs 0,63 Kvs 1,0 Kvs 1,6 Kvs 2,5 Kvs 4 Kvs 6,3 Kvs 10 Kvs 16 Kvs 25 Kvs 40 Kvs 49 Kvs 63 Kvs 78 = 002 = 004 = 006 = 010 = 016 = 025 = 040 = 063 = 100 = 160 = 250 = 400 = 490 = 630 = 780 Electric air heater TBLE-3-aaa-aaa-bbb-c Including built-in controller and connection cable with quick connector Duct connection dimensions: Ø 315 = 000-031 Capacity variant: For air heater: 3.0 kW Ø 315 = 030 4.5 kW Ø 315 = 045 7.5 kW Ø 315 = 075 Voltage: 400V =1 230V (Norway) =2 20090415 www.swegon.com GOLD Specification Electric air heater TBLE-4-aaa-aaa-bb-c Including built-in controller and connection cable with quick connector Duct connection dimensions: Ø 315 = 000-031 Ø 400 = 000-040 Ø 500 = 000-050  1000x400 = 100-040  1200x500 = 120-050  1400x600 = 140-060 Capacity variant: For air heater: 12 kW Ø 315 = 12 20 kW Ø 315 = 20 27 kW Ø 315 = 27 6.0 kW Ø 400 = 06 12 kW Ø 400 = 12 20 kW Ø 400 = 20 27 kW Ø 400 = 27 36 kW Ø 400 = 36 47.5 kW Ø 400 = 47 8 kW Ø 500 = 08 12 kW Ø 500 = 12 20 kW Ø 500 = 20 27 kW Ø 500 = 27 36 kW Ø 500 = 36 47 kW Ø 500 = 47 69 kW Ø 500 = 69 8.0 kW  1000x400 = 08 12 kW  1000x400 = 12 20 kW  1000x400 = 20 36 kW  1000x400 = 36 47.5 kW  1000x400 = 47 69 kW  1000x400 = 69 79 kW  1000x400 = 79 12 kW  1200x500 = 12 20 kW  1200x500 = 20 27 kW  1200x500 = 27 34 kW  1200x500 = 34 47.5 kW  1200x500 = 47 69 kW  1200x500 = 69 79 kW  1200x500 = 79 90 kW  1200x500 = 90 12 kW  1400x600 = 12 20 kW  1400x600 = 20 27 kW  1400x600 = 27 36 kW  1400x600 = 36 47.5 kW  1400x600 = 47 69 kW  1400x600 = 69 79 kW  1400x600 = 79 90 kW  1400x600 = 90 Voltage: 400V =1 230V (Norway) =2 We reserve the right to alter specifications. Electric air heater Including built-in controller and connection cable with quick connector TBLE-5-aaa-aaa Duct connection dimensions:  1600x800 = 160-080  1800x1000 = 180-100 Configuration: Capacity variant: Casing only 24 kW 34 kW 47 kW 63 kW 79 kW 90 kW 135 kW 34 kW 45 kW 55 kW 69 kW 90 kW 135 kW 170 kW Voltage: Casing only 400V 230V (Norway) Connection side: Right-hand Left-hand 20090415 For air heater:  1600x800  1600x800  1600x800  1600x800  1600x800  1600x800  1600x800  1800x1000  1800x1000  1800x1000  1800x1000  1800x1000  1800x1000  1800x1000 www.swegon.com 201 GOLD Specification Cooling coil Air cooler for chilled water (sizes 04-40) TBKA-4-aaa-aaa-b Connection dimensionn: Ø 315 Ø 400 Ø 500  1000x400  1200x400  1200x500  1400x500  1400x600  1600x600 Capacity variant: Capacity variant 1 = 1 (not sizes 1200x400, 1400x500, 1600x600) Capacity variant 2 =2 (Not sizes 1200x400, 1400x500, 1600x600) Capacity variant 3 = 3 (Sizes 1000x400, 1200x500, 1400x600 only) Capacity variant 4 = 4 (Sizes 1200x400, 1400x500, 1600x600 only) Capacity variant 5 = 5 (Size Ø 500 only) = 6 Capacity variant 6 (Size Ø 500 only) = 000-031 = 000-040 = 000-050 = 100-040 = 120-040 = 120-050 = 140-050 = 140-060 = 160-060 Air cooler for chilled water (sizes 50-80) TBKA-3-aaa-aaa Connection dimensions:  1600x800  1800x1000 Configuration: capacity variant: Casing only, L = 570 mm Casing only, L = 792 mm Capacity variant 1 Capacity variant 2 Capacity variant 3(size 1800x1000 only) Capacity variant 4(size 1800x1000 only) Capacity variant 5 (size 1600x800 only) Capacity variant 6 (size 1600x800 only) Droplet eliminator Without With Connection side: Right-hand Left-hand = 160-080 = 180-100 We reserve the right to alter specifications. Valve set for cooling and heating 2 (3)-way valve including actuator. 202 20090415 Valve size: Kvs 0,25 Kvs 0,40 Kvs 0,63 Kvs 1.0 Kvs 1.6 Kvs 2.5 Kvs 4 Kvs 6.3 Kvs 10 Kvs 16 Kvs 25 Kvs 40 Kvs 49 Kvs 63 Kvs 78 TBVA-1-aaa = 002 = 004 = 006 = 010 = 016 = 025 = 040 = 063 = 100 = 160 = 250 = 400 = 490 = 630 = 780 www.swegon.com GOLD Specification Air cooler, direct expansion (sizes 04-12) Connection dimensions: Ø 315 Ø 400 Ø 500 Capacity variant: Capacity variant 1 Capacity variant 3 (size Ø 500 only) Number of sections: 1 section TBKC-3-aaa-aaa-b-c = 000-031 = 000-040 = 000-050 =1 =3 =1 Air cooler, direct expansion (sizes 14-40) TBKC-2-aaa-aaa-b-c Connection dimensions:  1000x400  1200x500  1400x600 Capacity variant: Capacity variant 1 =1 Capacity variant 2 =2 Capacity variant 3 =3 (sizes 1200x50-1400x600 only) Number of sections: 1 section 2 sections = 100-040 = 120-050 = 140-060 Air cooler, direct expansion (sizes 50-80) TBKC-3-aaa-aaa Connection dimensions:  1600x800 = 160-080  1800x1000 = 180-100 Configuration: Capacity variant: Casing only, L = 570 mm Casing only, L = 792 mm Capacity variant 1 Capacity variant 2 Capacity variant 3 Number of sections: Casing only 1 section 2 sections Droplet eliminator Without With Connection side: Right-hand Left-hand =1 =2 We reserve the right to alter specifications. 20090415 www.swegon.com 203 GOLD Specification Coil section, heating and cooling Electric heating and cooling Connection dimensions:  1600x800  1800x1000 TBEK-2-aaa-aaa = 160-080 = 180-100 Configuration: Capacity variant: Without electric air heater 25 kW 34 kW 47 kW 63 kW 79 kW 90 kW (400 V only) 135 kW (400 V only ) 34 kW 45 kW 55 kW 69 kW 90 kW 135 kW (400 V only ) Connection dimensions:  1600x800  1800x1000 TBLK-3-aaa-aaa = 160-080 = 180-100 Configuration:  1600x800  1600x800  1600x800  1600x800  1600x800  1600x800  1600x800  1800x1000  1800x1000  1800x1000  1800x1000  1800x1000  1800x1000 Voltage: 400V 230V Cooling coil: Without air cooler (length 570 mm) Without air cooler (length 792 mm) Capacity variant 1 Capacity variant 2 Capacity variant 3 (size 1800x1000 only) Capacity variant 4 (size 1800x1000 only) Capacity variant 5 (size 1600x800 only) Capacity variant 6 (size 1600x800 only) Direct expansion, capacity variant 1 Direct expansion, capacity variant 2 Direct expansion, capacity variant 3 Sections: (Applicable to direct expansion) 1 section 2 sections Droplet eliminator for air cooler: Without With Connection side: Right-hand Left-hand 204 Coil section, heating and cooling We reserve the right to alter specifications. Capacity variant, air heater: Without air heater Capacity variant 1 Capacity variant 2 Capacity variant 3 Air cooler: Without air cooler (length 570 mm) Without air cooler (length 792 mm) Water, capacity variant 1 Water, capacity variant 2 Capacity variant 3 (size 1800x1000 only) Capacity variant 4 (size 1800x1000 only) Capacity variant 5 (size 1600x800 only) Capacity variant 6 (size 1600x800 only) Direct expansion, capacity variant 1 Direct expansion, capacity variant 2 Direct expansion, capacity variant 3 Sections: (Applicable to direct expansion) 1 section 2 sections Droplet eliminator for air cooler: Without With Connection side: Right-hand Left-hand 20090415 www.swegon.com GOLD Specification Mixing section GOLD SD Mixing section for the GOLD SD For unit size 04, 05 08 14, 20 25, 30 35, 40 50, 60 70, 80 Variant: Two dampers Three dampers Installation Alternative 1 Alternative 2 (three dampers only) Hoods Outdoor air hood Including roof duct TBBD-1-aa-b-c = 05 = 08 = 20 = 30 = 40 = 60 = 80 = 0031 = 0040 = 0050 = 0606 = 0909 Exhaust air hood Including roof duct =1 = 2 =1 = 2 For unit size: 04, 05 08 12 14, 20 25, 30, 35, 40 TBHA-1-aaaa For unit size: 04, 05 08 12 14, 20 25, 30, 35, 40 TBHB-1-aaaa = 0031 = 0040 = 0050 = 0606 = 0909 Dual-purpose hood Including roof duct For unit size: 04, 05 08 12 TBHC-1-aaaa = 0031 = 0040 = 0050 Exterior Wall Hood We reserve the right to alter specifications. 20090415 For unit size: 04, 05 08 12 TBHE-1-aaaa = 0031 = 0040 = 0050 www.swegon.com 205 GOLD Specification Outdoor installation Filters Carbon filter TBFK-3-aa-b Number of carbon filter cartridges 17 = 017 24 = 024 36 = 036 50 = 050 72 = 072 98 = 098 Carbon filter cartridges:: Without With =0 =1 Prefilter Connection size Ø 315 Ø 400 Ø 500  1000x400  1200x500  1400x600  1600x800  1800x1000 TBFA-1-aaa-aaa-b = 000-031 = 000-040 = 000-050 = 100-040 = 120-050 = 140-060 = 160-080 = 180-100 Type of filter Aluminium Compact Version: 1 m 3 m 5 m 10 m 15 m = 01 = 03 = 05 = 10 = 15 =1 =2 Pressure transducer TBLZ-1-23-aa Contains pressure transducer and connection cable. Roof for outdoor installation GOLD RX/PX/CX, sizes 04-40 TBTB-1-aa-b-c-d-e-f Complete with necessary assembly parts For unit size: 04, 05 = 05 08 = 08 12 = 12 14, 20 = 20 25, 30 = 30 35, 40 = 40 50, 60 = 60 70, 80 = 80 For air handling unit combination: GOLD RX, (rotary heat exchanger) = 1 GOLD PX (plate heat exchanger, not applicable to sizes 35-80) =2 GOLD CX (coil heat exchanger, not applicable to sizes 04-30) =3 GOLD SD, Fan (not applicable to sizes 04-08) =4 GOLD SD, fan + filter (all SD sizes 04-08 and SD sizes 14-80 in this combination) =5 GOLD SD, fan + filter + coil heat exch. (SD sizes 14-80 in this combination) = 6 Air recirculation section Without =0 With (not SD) =1 206 We reserve the right to alter specifications. 20090415 CoolDX Without =0 With roof, assem. with GOLD (not appl. to sizes 04/05/80, not GOLD SD) =1 With roof, stand-alone (not appl. to sizes 04/05/80, not GOLD SD) =2 Coil section Without =0 TBLA air heater (not applicable to sizes 04-40) =1 TBLE air heater, length = 632 mm (not applicable to sizes 04-40) =2 Air heater, TBLE, length = 792 mm or Air cooler TBKA or TBKC, length = 792 mm (not sizes 04-40) =3 Air cooler TBKA or TBKC, length = 570 mm (not sizes 04-40) =4 Dual-purpose section, TBLK, length = 1654 mm (not sizes 04-40) =5 1,716 mm (not appl. to sizes 04-40) = 6 TBEK dual-purpose section, length = Dual-purpose section, TBEK or TBLK, length = 1876 mm (not sizes 04-40) = 7 Dual-purpose section, TBEK, length = 1938 or 2098 mm (not sizes 04-40) = 8 Coil location (to be left out for sizes 04-40) Lower level = 1 Upper level = 2 www.swegon.com GOLD Specification Roof for outdoor installation, CoolDX Complete with necessary assembly parts For CoolDX size: 08 12 20 30 40 TBTA-3-aa-04 = 08 = 12 = 20 = 30 = 40 Intake air section for outdoor installation TBTA-3-aa-b-1 Complete with raindrop separator and means of attachment For unit size: 04, 05 = 05 08 = 08 12 = 12 14, 20 = 20 25, 30 = 30 35, 40 = 40 50, 60 = 60 70, 80 = 80 Version Louvre Casing for silencer installed outdoors TBTA-1-aa-01 For unit size: 14, 20 = 20 25, 30 = 30 35, 40 = 40 50, 60 = 60 70, 80 = 80 Casing for damper installed outdoors TBTA-1-aa-02 For unit size: 14, 20 = 20 25, 30 = 30 35, 40 = 40 50, 60 = 60 70, 80 = 80 =1 Extract air hood for outdoor installation TBTA-2-aa-2 Complete with netting and means of attachment For unit size: 04, 05 = 05 08 = 08 12 = 12 14, 20 = 20 25, 30 = 30 35, 40 = 40 50, 60 = 60 70, 80 = 80 Cover hood, for GOLD CX pipework pack. TBXZ-1-41-aa For unit size: 35, 40 50, 60 70, 80 = 40 = 60 = 80 We reserve the right to alter specifications. 20090415 www.swegon.com 207 GOLD Specification Extra Accessories Mechanical equipment Electrical and control equipment Stand, GOLD RX Mounting kit For unit size: 04, 05 08 TBLZ-1-aa-02 = 05 = 08 Stand, GOLD SD Mounting kit. For unit size: 04, 05 08 TBLZ-1-aa-04 = 05 = 08 Legs,GOLD PX GOLD Air handling units, sizes 04-40: TBLZ-1-43 Base frame, CoolDX TBLZ-1-44 Used also as a base beam for the CoolDX in combination with the GOLD PX Cover holder For unit sizes 04, 05 and 08 TBLZ-1-10-07 Slip clamps Set for one joint TBLZ-2-aa-08 For unit size: 14, 20 25, 30 35, 40 50, 60 70, 80 Metu connection Connection side:  1000x400  1200x500  1400x600  1600x800  1800x1000 = 20 = 30 = 40 = 60 = 80 Extension cable TBLZ-1-05-a With quick connector Version: 5 m long for heater, el. or water coil = 1 5 m long for supply air sensor = 2 8 m long for hand-held micro terminal TBIQ pressure transducers =3 Connection cable TBLZ-1-26-aa For hand-held micro terminal, pressure transducers, TBIQ Version: 0,25 m = 00 1 m = 01 3 m = 03 5 m = 05 10 m = 10 15 m = 15 Extension kit for hand-held micro terminal TBLZ-2-13 For extending the cable 6 - 50 m Communication unit For interface: LON FFT-10 Trend TBLZ-3-1-a-41 = 1 =2 External connection of the GOLD unit TBXZ-1-aaa-aaa-10 = 100-040 = 120-050 = 140-060 = 160-080 = 180-100 Support foot, 1 pc For base beams for size 12, 14, 20, 25, 30, 35, 40, 50, 60, 70 and 80 units TBXZ-1-36 Rubber tile, 1 pc For support foot TBXZ-1-37 Modem, GSM Modem, analogue =1 =2 Room sensor For wall mounting, enclosure class IP20. We reserve the right to alter specifications. TBLZ-1-24 Sensor, outdoor/room TBLZ-1-25 Watertight for wall mounting, enclosure class IP43. Can also be used as a room sensor if specs require a higher enclosure class. Pressure transducer TBLZ-1-23-aa Contains pressure transducer and connection cable. Version: 1 m 3 m 5 m 10 m 15 m = 01 = 03 = 05 = 10 = 15 Extra hand-held micro terminal Including holder and 3 m long cable 208 TBLZ-2-3-41-a 20090415 TBLZ-1-22 www.swegon.com GOLD Specification MMC circuit card Multi-media circuit card for program transmissions and logging Version: Without software = 1 With software, GOLD = 2 TBLZ-1-28-a Transformer, 230/400V TBLZ-2-aa-11 For connecting the air handling unit to 230V mains power supply Transformer capacity: 7 kVA 11 kVA 13.9 kVA 17.5 kVA 22.2 kVA 27.7 kVA 34.6 kVA 43.6 kVA 55,4 kVA = 07 = 11 = 14 = 18 = 22 = 28 = 35 = 44 = 55 TBIQ-2-1-aa Strap-on sensor ELQZ-1-428-3-a With spring return =1 With spring return and limit switch =2 Timer 0-2 hour prolonged operation Version: For strap-on mounting ELQZ-1-406-a =1 TBLZ-1-30 TBLZ-1-31-a Version: For strap-on mounting =1 Without indicating LED With indicating LED =0 =1 Adaptor, modular/terminal TBLZ-1-55 Occupant detection sensor TBLZ-1-56 Internal duct temperature sensor TBLZ-1-32 Length of cable Air quality sensor, room 20090415 TBLZ-1-58-aa 1 m = 01 2,2 m = 02 4,3 m = 04 Air quality sensor, in-duct We reserve the right to alter specifications. =1 =2 Push button for prolonged operation ELQZ-2-455-a-b = 00 = 01 = 03 = 05 = 10 = 15 Humidity sensor For dehumidification and dew point control Measuring point: Supply air duct =1 Extract air duct =2 600 mm 1500 mm Damper actuator TBLZ-1-47 External duct temp. sensor, IQnomic Plus TBLZ-2-49-a Mounting fittings for smoke detector, for circular or insulated ducts TBLZ-1-53 Timer, electronic Version: 0,25 m 1 m 3 m 5 m 10 m 15 m Separate cubicle for smoke function TBLZ-2-48-2 Including control unit for smoke detector and damper exercising, damper: 24 V AC Venturie tube TBLZ-1-46 IQnomic Plus Functional module and connection cable TBLZ-1-48-a Including control unit for smoke detector =1 Including control unit for smoke detector and damper installation =2 Smoke detector, optical Transformer 230/24 VAC Separate cubicle for smoke function ELQZ-2-504-2 ELQZ-2-504 www.swegon.com 209 GOLD Specification Control box for Xzone TBLZ-2-50-a-b-cc Control of one extra temperature zone, max. Junction box conforming to IP54 TBLZ-1-61 For TBLZ-1-05-a extension cable and TBLZ-1-55 adaptor. Freeze protection sensor Without = 0 With =1 Type of sensor Supply air = 1 Supply air/Extract air = 2 Supply air/Room air = 3 Connection cable 1 metre 3 metres 5 metres 10 metres 15 metres = 01 = 03 = 05 = 10 = 15 TBLZ-1-51 ReCO2 Complete set of components for controlling the function for mixing. The pressure sensor and the IQnomic Plus are included. The air quality sensor must be ordered separately. The outdoor air damper must be of modulating type. The air handling unit must be equipped with an air recirculation section. Applicable to sizes 14-80 only. Control of air heater, preheating Including temperature sensor for duct and IQnomic Plus with 0.25 metre long cable TBLZ-1-53-a Freeze protection sensor Without =0 With =1 All Year Comfort TBLZ-1-59-a-b-cc El. equipment cubicle for control of inlet flow water. Function Cooling reg. = 1 Heating reg. = 2 Cooling and heating reg. = 3 Room sensor Without = 0 With = 1 Connection cable 1 metre = 01 3 metres = 03 5 metres = 05 10 metres = 10 15 metres = 15 > 15 metres = xx 210 We reserve the right to alter specifications. 20090415 www.swegon.com