Preview only show first 10 pages with watermark. For full document please download

0.8 1.0 1.2 1.4 1.6 0 100 200 300 400 500 600 700 Discharge Time

   EMBED


Share

Transcript

Type : Alkaline High Drain Button Cell Chemical System : Alkaline Manganese Dioxide Nominal Voltage : 1.5Volts Model No.: GP192 Nominal Dimensions : Ø7.9mm×3.6mm Application : Watch (with alarm and lamp), Average Weight calculator, electronic toys, melody card, ... etc. : 0.5g Date Code : Unless otherwise specified, each cell Will carry a numeric year code and an alphabetical month code. Shelf Life : Not less than 90% of the service capacity within first year. , not less than 85% of the service capacity with third year storage at 20 ±2 oC 45-75%RH Close Circuit Voltage : 1.30 Volts (min.)(load resistor 100Ω at 20 ± 2 oC for 0.1 to 2 seconds) : 900hrs (at 50 kΩ load) Nominal Service Life(to 1.0V at 20 ±2 150 days (at 200 kΩ load) o C) : 24mAh(at 30 kΩ load) Average Service Capacity (to 1.0V at 20 ±2 oC) LR41 JIS LR41 Voltage(V) 1.6 30kΩ load 1.4 Cross References: IEC Typical Discharge characteristics at 20 ± 2 oC Eveready 192 Varta V3GA 1.2 1.0 0.8 0 100 200 300 400 500 600 700 Discharge Time(hrs) The information (subject to change without prior notice) contained in this document is for reference only and should not be used as a basis for product guarantee or warranty. For applications other than those described here, please consult your nearest GP Sales and Marketing Office or Distributors. www.gpbatteries.com Manufacturer reserves the right to alter or amend the design, model and specification without prior notice. Copyright@GPI International Ltd. – All rights reserved BQS10010 Rev.02