Preview only show first 10 pages with watermark. For full document please download

088u0215 - Danfoss Heating

   EMBED


Share

Transcript

088U0215 GB Instruction CF-RF Room Thermostat with Infrared Floor Sensor Instruction CF-RF Room Thermostat with Infrared Floor Sensor 2 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011 Instruction CF-RF Room Thermostat with Infrared Floor Sensor Index 1. Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. Temperature Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 4. Transmission Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5. Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6. Uninstallation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 7. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 8. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figures and illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 © Danfoss 05/2011 VIUHR402 Danfoss Heating Solutions 3 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 1. Functional Overview Front (fig. 1)  Up/down selector  Push button  Red LED (behind the cover) InfraRed floor sensor LED modes Permanent light . . . . . . ON No light . . . . . . . . . . . . . . OFF Slow flashing . . . . . . . . Flashes Fast flashing . . . . . . . . . Flickers Back (fig. 2)  Back plate  Back plate lock/unlock (turn 90°)  Screw hole for wall mounting  Battery placement  Screw and wall plug Note: To activate batteries please remove enclosed strips from batteries. 4 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 2. Installation Note: Assignment of Room Thermostats to Master Controller should be within a distance of 1.5 m. Activate Install mode on Master Controller (fig. 1) • Use the menu selection button  to select the Install mode. Install LED  flashes. • Activate Install mode by pressing OK. Install LED  goes ON. Activate Install mode on room thermostat • Press the push button . LED  and  flicker during communication. Select output on Master Controller • All available output LEDs on Master Controller  light up, and the first one flashes. • Press output selection button  to select desired output (flashes). Accept with OK . • All output LEDs  go OFF. Selected output stays ON shortly. Room thermostat installation status • Satisfactory: LED  goes OFF. • Not satisfactory: LED  flashes 5 times. Note: A room thermostat can be assigned to several outputs if needed by repeating the installation process. © Danfoss 05/2011 VIUHR402 Danfoss Heating Solutions 5 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 3. Temperature Settings Digital Display (fig. 1) SET Set value adjustment MIN Minimum temperature limitation MAX Maximum temperature limitation Transmission link icon Low battery indicator Alarm icon Settings only available from CF-RC Remote controller: Lock icon Timer icon Room temperature icon Floor temperature icon Changing default display temperature (fig. 1) 1. The actual room temperature is shown in the display as default. 2. To change default display from actual room tempera- ture to actual floor surface temperature, press and hold the push button  until SET MAX is shown in the display. 3. Press the button  shortly and repeatedly until or is flashing in the display. 4. Press the up/down selector  to select the new default display temperature: Room temperature Floor surface temperature. 6 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011 Instruction CF-RF Room Thermostat with Infrared Floor Sensor Setting of room temperature 1. Make sure actual room temperature is shown in the display. 2. Press the up/down selector  to set the desired room temperature value. SET is shown in the display. 3. When releasing the up/down selector  the display returns to actual temperature. Note: The thermostat regulates the floor heating system according to room temperature set point, within the maximum and minimum limitations defined for the floor surface temperature. Room temperature limitation 1. Make sure actual room temperature is shown in the display. 2. Press the push button  until SET MAX is shown in the display. 3. Press the up/down selector  to set the maximum room temperature limitation. 4. Press the push button  shortly, SET MIN is shown in the display. 5. Press the up/down selector  to set the minimum room temperature limitation. 6. Press the push button  shortly and the actual floor surface temperature is shown in the display. © Danfoss 05/2011 VIUHR402 Danfoss Heating Solutions 7 Instruction CF-RF Room Thermostat with Infrared Floor Sensor Floor surface temperature limitation 1. Ensure actual floor surface temperature is shown in the display illustrated by . 2. Press and hold the push button  until SET MAX is also shown in the display. 3. Press the up/down selector  to set the maximum floor surface temperature limitation. 4. Press the push button  shortly, SET MIN is also shown in the display. 5. Press the up/down selector  to set the minimum floor surface temperature limitation. IMPORTANT! As heat emission from the floor may vary slightly depending on floor covering - and thereby cause inaccurate temperature measurement - it may be necessary to adjust the setting of max. and min. floor surface temperatures accordingly. It is important always to follow recommendations from the floor manufacturer regarding max. floor surface temperature. It is recommended always to include mixing shunt for floor heating circuits in order to ensure optimal flow temperature. - In addition to minimised energy consumption, correct setting of the flow temperature will eliminate the risk of excessive heat transfer to the floor. 8 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 4. Transmission Test Initiate transmission test on room thermostat (fig. 1) • Press the push button . • LED  goes ON. Link test is satisfactory • LED  goes OFF. Link test is unsatisfactory • LED  flashes 5 times. No Link connection to room thermostat • Try to relocate room thermostat in the room. • Or install CF-RU Repeater Unit and locate between Master Controller and room thermostat. Note: When connected to a room thermostat, the Master Controller output LED(s)  flash(es) during Link test. © Danfoss 05/2011 VIUHR402 Danfoss Heating Solutions 9 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 5. Mounting Placing a room thermostat (fig. 3) • A room thermostat should be placed in accordance with fig. 3. IMPORTANT! Wherever possible, a room thermostat should be installed at a place where the effect of sunlight, strong artificial light (e.g. halogen spotlight), draught, other heat-emitting equipment (e.g. TVs) etc. is avoided. Please note that no furniture, rugs etc. should be permanently placed within the area of the InfraRed Floor Sensor as shown in fig. 3. 6. Uninstallation Activate Uninstall mode on Master Controller (fig. 1) • Use the Menu selection button  to choose the Uninstall menu. Uninstall LED  flashes. • Activate Uninstall mode by pressing OK . Uninstall LED  goes ON. Deselect output on Master Controller • Select output to be removed by output selection button . • Remove flashing output  with OK . 10 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 7. Specifications Temperature setting range 5-35°C Transmission frequency 868.42 MHz Transmission range in normal buildings (up to) 30 m Transmission power < 1 mW Battery Alkaline 2xAA, 1.5 V Battery lifetime (up to) 1-3 years Ambient temperature 0-50°C IP class 21 Floor ensor accuracy +/- 1°C Floor sensor emission coefficient 0.9 © Danfoss 05/2011 VIUHR402 Danfoss Heating Solutions 11 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 8. Troubleshooting Error Indication Possible Cause The LED, and flashes every 5th minute Low battery The LED, and flashes every 30 sec. Critical low battery The LED, flashes Critical low battery - transmission has stopped The LED, 5 times , and and E03 and E05 and 12 Danfoss Heating Solutions flashes Installation/Link Test is unsatisfactory Actuator error on output (CF-MC) Room temperature below 5°C VIUHR402 © Danfoss 05/2011 Instruction © Danfoss 05/2011 CF-RF Room Thermostat with Infrared Floor Sensor VIUHR402 Danfoss Heating Solutions 13 Instruction CF-RF Room Thermostat with Infrared Floor Sensor Fig. 1 14 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011 Instruction CF-RF Room Thermostat with Infrared Floor Sensor Fig. 2 Fig. 3 1,5 m. 0,5 m. 0,25 m. © Danfoss 05/2011 VIUHR402 Danfoss Heating Solutions 15 Instruction CF-RF Room Thermostat with Infrared Floor Sensor 16 Danfoss Heating Solutions VIUHR402 © Danfoss 05/2011