Preview only show first 10 pages with watermark. For full document please download

1 2 3 4 5 6 Abcde 1 2 3 4 5 6 Abcde

   EMBED


Share

Transcript

6 5 4 3 (2) 1 1/4" CONDUITS 2 1 ROUGH-IN GENERAL NOTES: (2) 1 1/4" CONDUITS CEILING 1. TERMINATE ALL ROUGH-IN CONDUITS WITH 90 DEGREE SWEEP AND BUSHINGS IN NEAREST CONCEALED ACCESSIBLE CEILING SPACE. (2) 1 1/4" CONDUITS POWER RECEPTACLE +96" A.F.F. U.N.O. REFER TO FLOOR PLANS TWO-GANG EACH OUTLET BOX FLOOR E 2. CONDUIT BEND RADIUS TO BE COMPLIANT WITH BICSI TDMM MANUAL 12TH ED. DM CUT AND GROMMET REAR OF CABINET FOR CABLE AND POWER ACCESS UNLESS MANUFACTURER PROVIDED. +36" A.F.F. E TWO-GANG OUTLET BOX WALL MOUNT CABINET 3. ALL ROUGH-IN CONDUITS ARE 1" UNLESS OTHERWISE NOTED. 4. PROVIDE NO MORE THAN THE EQUIVALENT OF (2) 90 DEGREE BENDS IN A SINGLE CONDUIT RUN. 5. ROUGH-IN OUTLET BOXES TO HAVE 90 DEGREE OPENING CORNERS ON FACE OF BOX. 6. ALL ROUGH-INS BY ELECTRICAL CONTRACTOR. Project No. 2013-005.GVE Project Date 02.27.2017 Produced MD, JB FLOOR 4E WALL-MOUNT SOUND CABINET ROUGH-IN DETAIL D 2E WALL-MOUNTED DISPLAY MONITOR ROUGH-IN D INTERIOR CEILING SPACE THREADED ROD (TYPICAL) # Revision Date CABLE SUPPORT (TYPICAL) SINGLE-GANG OUTLET BOX MAXIMUM = 60" POINT TO POINT EXTERIOR GRADE NOTE: PROVIDE ADDITIONAL SUPPORT HARDWARE AS REQUIRED TO COMPLY WITH REFERENCED STANDARDS 36" MAXIMUM CR 12" MINIMUM +48" A.F.F. These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. CEILING 4D 1D CABLE SUPPORT DETAIL C W P 3 C ACCESS CONTROL CARD READER ROUGH-IN ACCESSIBLE CEILING (1) 1"CONDUIT PROVIDE (3) HORIZONTAL UTP CABLES PROVIDE (1) HORIZONTAL UTP CABLE SURV CEILING S AP 2230 Green Valley Road New Albany, IN 47150 S SINGLE-GANG OUTLET BOX NEAREST FULL HEIGHT WALL NON-FULL HEIGHT WALL (2) 1" CONDUITS EXTERIOR WALL C 1 BUILDING INTERIOR +18" A.F.F. TELECOM OUTLET BOX GRADE NOTE: REFER TO ARCHITECTURAL ELEVATIONS FOR SURVEILLANCE CAMERA LOCATIONS. CONFIRM FINAL OUTLET BOX LOCATIONS IN FIELD. SLAB EXTERIOR SURVEILLANCE ROUGH-IN 1B KEY PLAN TELECOM OUTLET ROUGH-IN IN NON-FULL HEIGHT WALL PROVIDE (4) HORIZONTAL UTP CABLES New Albany-Floyd County CSC GENERAL NOTES: QUANTITY OF RJ 45 JACKS ASINDICATED HDMI HDMI GENERAL NOTES 1. WHERE TELECOMMUNICATIONS OUTLETS ARE INSTALLED IN MULTICOMPARTMENT SURFACE RACEWAY, PROVIDE 106 JACK FRAMES AS REQUIRED AND STANDARD FACEPLATES TO MATCH ELECTRICAL POWER OUTLET. CEILING PLAN NOTES: 1 VGA REFER TO SCHEDULE FOR CONDUIT QUANTITY FIRST POSITION DESIGNATED FOR VOICE SERVICES AT FACULTY AND STAFF DESK LOCATIONS. REFER TO SCHEDULE FOR OUTLET TYPE 3.5 AUDIO FLOOR A .# / V A PROVIDE QUANTITY OF HORIZONTAL UTP CABLES AS INDICATED 2/24/2017 2:42:26 PM C:\_RevitLocal\2013-005.GVE_Bldg001_T_2016\2013-005.GVE_Bldg001_T_2016_jboosey.rvt 2013-005.GVE_New Albany-Floyd County CSC_Green Valley Elementary_ T-501_ TELECOMMUNICATIONS DETAILS REFER TO SCHEDULE FOR MOUNTING HEIGHT 6A 1A TYPICAL WALL-MTD. TELECOM. ROUGH-IN Green Valley Elementary TELECOMMUNICATIONS DETAILS FACE PLATE DETAILS 6 5 N 4B PROVIDE (2) HORIZONTAL UTP CABLES A B 4 2 B B FINISHED FLOOR D 4 3 2 1 T-501