Transcript
SIMATIC NET Industrial Ethernet SCALANCE X101-1 SCALANCE X101-1FL SCALANCE X101-1LD SCALANCE X101-1POF Commissioning Manual
07/2008 A2B00051521A
Preface
1
Introduction
2
Network Topologies
3
Product Characteristics
4
Installation and Maintenance
5
Notes on the CE Mark
6
References
7
Dimension Drawings
8
Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to avoid property damage. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only have no safety alert symbol. Depending on the danger level, the notices are displayed in descending order as follows. Danger indicates that death or severe personal injury will result if proper precautions are not taken. Warning indicates that death or severe personal injury may result if proper precautions are not taken. Caution with safety alert symbol indicates that minor personal injury can result if proper precautions are not taken. Caution without safety alert symbol indicates that property damage can result if proper precautions are not taken. Notice indicates that an unintended result or situation can occur if the corresponding information is not taken into account. When several danger levels apply, the notices of the highest level (lower number) are always displayed. If a notice refers to personal damages with the safety alert symbol, then another notice may be added warning of property damage.
Qualified Personnel The device/system may only be set up and operated in conjunction with this documentation. Only qualified personnel should be allowed to install and work on the equipment. Only qualified personnel should be allowed to install and work on the equipment. Qualified persons are defined as persons who are authorized to commission, to earth, and to tag circuits, equipment and systems in accordance with established safety practices and standards.
Intended Use Please note the following: Warning This device and its components may only be used for the applications described in the catalog or technical description, and only in connection with devices or components from other manufacturers approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and maintained as recommended.
Trademarks All designations marked with ® are registered trademarks of Siemens AG. Other designations in this documentation might be trademarks which, if used by third parties for their purposes, might infringe upon the rights of the proprietors.
Copyright Siemens AG 2008. All rights reserved. Reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in the manual are reviewed regularly, and any necessary corrections will be included in subsequent editions.
Siemens AG Automation and Drives Group P.O. Box 4848, D-90327 Nuremberg (Germany)
Siemens AG 2008 Technical data subject to change
Siemens Aktiengesellschaft
A2B00051521A
Table of Contents 1
Preface ................................................................................................................................................... 1-1 1.1
2
Introduction............................................................................................................................................. 2-1 2.1
3
4
Preface....................................................................................................................................... 1-1 Introduction ................................................................................................................................ 2-1
Network Topologies ................................................................................................................................ 3-1 3.1
Network Topologies ................................................................................................................... 3-1
3.2
Coupling of Network Segments ................................................................................................. 3-4
Product Characteristics........................................................................................................................... 4-1 4.1
Overview .................................................................................................................................... 4-1
4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 4.2.6 4.2.7 4.2.8 4.2.9 4.2.10
SCALANCE X101-1 ................................................................................................................... 4-2 SCALANCE X101-1 Components Supplied .............................................................................. 4-2 SCALANCE X101-1 Unpacking and Checking.......................................................................... 4-2 SCALANCE X101-1 Product Characteristics............................................................................. 4-3 SCALANCE X101-1 TP Port...................................................................................................... 4-4 SCALANCE X101-1 FO Port ..................................................................................................... 4-5 SCALANCE X101-1 Power Supply and Signaling Contact ....................................................... 4-6 SCALANCE X101-1 Button........................................................................................................ 4-7 Cascade Connection of two Media Converters ......................................................................... 4-8 SCALANCE X101-1 Displays .................................................................................................... 4-9 SCALANCE X101-1 Technical Specifications ......................................................................... 4-11
4.3 4.3.1 4.3.2 4.3.3 4.3.4 4.3.5 4.3.6 4.3.7 4.3.8 4.3.9 4.3.10
SCALANCE X101-1FL............................................................................................................. 4-14 SCALANCE X101-1FL Components Supplied ........................................................................ 4-14 SCALANCE X101-1FL Unpacking and Checking.................................................................... 4-14 SCALANCE X101-1FL Product Characteristics ...................................................................... 4-15 SCALANCE X101-1FL TP Port................................................................................................ 4-16 SCALANCE X101-1FL FO Port ............................................................................................... 4-17 SCALANCE X101-1FL Power Supply and Signaling Contact ................................................. 4-18 SCALANCE X101-1FL Button ................................................................................................. 4-20 Cascade Connection of two Media Converters ....................................................................... 4-20 SCALANCE X101-1FL Displays .............................................................................................. 4-21 SCALANCE X101-1FL Technical Specifications ..................................................................... 4-23
4.4 4.4.1 4.4.2 4.4.3 4.4.4 4.4.5 4.4.6 4.4.7 4.4.8 4.4.9 4.4.10
SCALANCE X101-1LD ............................................................................................................ 4-26 SCALANCE X101-1LD Components Supplied........................................................................ 4-26 SCALANCE X101-1LD Unpacking and Checking ................................................................... 4-26 SCALANCE X101-1LD Product Characteristics ...................................................................... 4-27 SCALANCE X101-1LD TP Port ............................................................................................... 4-28 SCALANCE X101-1LD FO Port............................................................................................... 4-29 SCALANCE X101-1LD Power Supply and Signaling Contact................................................. 4-30 SCALANCE X101-1LD Button ................................................................................................. 4-32 Cascade Connection of two Media Converters ....................................................................... 4-32 SCALANCE X101-1LD Displays.............................................................................................. 4-33 SCALANCE X101-1LD Technical Specifications..................................................................... 4-35
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
iii
Table of Contents 4.5 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.5.6 4.5.7 4.5.8 4.5.9 4.5.10 5
6
Installation and Maintenance .................................................................................................................. 5-1 5.1 5.1.1 5.1.2 5.1.3
Installation .................................................................................................................................. 5-1 Installation on a DIN Rail............................................................................................................ 5-2 Installation on a SIMATIC S7 DIN Rail ...................................................................................... 5-4 Wall Mounting ............................................................................................................................ 5-5
5.2
Grounding .................................................................................................................................. 5-5
5.3
Assembling the IE FC Standard Cable ...................................................................................... 5-6
5.4
Maintenance............................................................................................................................... 5-8
Notes on the CE Mark ............................................................................................................................ 6-1 6.1
7
Notes on the CE Mark................................................................................................................ 6-1
References ............................................................................................................................................. 7-1 7.1
8
SCALANCE X101-1POF.......................................................................................................... 4-38 SCALANCE X101-1POF Components Supplied ..................................................................... 4-38 SCALANCE X101-1POF Unpacking and Checking ................................................................ 4-38 SCALANCE X101-1POF Product Characteristics ................................................................... 4-39 SCALANCE X101-1POF TP Port ............................................................................................ 4-40 SCALANCE X101-1POF FO Port ............................................................................................ 4-41 SCALANCE X101-1POF Power Supply and Signaling Contact .............................................. 4-42 SCALANCE X101-1POF Button .............................................................................................. 4-44 Cascade Connection of two Media Converters ....................................................................... 4-44 SCALANCE X101-1POF Displays ........................................................................................... 4-45 SCALANCE X101-1POF Technical Specifications .................................................................. 4-47
References ................................................................................................................................. 7-1
Dimension Drawings............................................................................................................................... 8-1 8.1
Dimension Drawing .................................................................................................................... 8-1
Tables Table 4-1
Overview of the product characteristics ..................................................................................... 4-1
Table 4-2
Overview of the possible attachments ....................................................................................... 4-1
Figures Figure 3-1
Electrical/optical bus topology with SCALANCE X101-1 ........................................................... 3-1
Figure 3-2
Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a extension for Optical Lines with SCALANCE X101-1LD Media converter ................................ 3-2
Figure 3-3
Electrical Ring, Example with SCALANCE X204IRT as Redundancy Manager, X208 and conversion to a Optical Line with SCALANCE X101-1 or X101-1LD Media converter ............. 3-2
Figure 3-4
Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a extension for Optical Lines with SCALANCE X101-1LD Media converter ................................ 3-3
iv
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Table of Contents Figure 3-5
Stand-By Coupling of two Redundant Rings via Master / Slave Concept of SCALANCE X-400. Coupling is realized with SCALANCE X101-1 or X101-1LD Media converter .......................... 3-4
Figure 4-1
SCALANCE X101-1 ................................................................................................................... 4-3
Figure 4-2
RJ-45 connector pinout.............................................................................................................. 4-4
Figure 4-3
Power supply SCALANCE X101-1 ............................................................................................ 4-6
Figure 4-4
Connector pinout........................................................................................................................ 4-6
Figure 4-5
Signaling contact SCALANCE X101-1 ...................................................................................... 4-7
Figure 4-6
Connector pinout........................................................................................................................ 4-7
Figure 4-7
SCALANCE X101-1FL............................................................................................................. 4-15
Figure 4-8
RJ-45 connector pinout............................................................................................................ 4-16
Figure 4-9
Power supply SCALANCE X101-1FL ...................................................................................... 4-18
Figure 4-10
Connector pinout...................................................................................................................... 4-18
Figure 4-11
Signaling contact SCALANCE X101-1FL ................................................................................ 4-19
Figure 4-12
Connector pinout...................................................................................................................... 4-19
Figure 4-13
SCALANCE X101-1LD ............................................................................................................ 4-27
Figure 4-14
RJ-45 connector pinout............................................................................................................ 4-28
Figure 4-15
Power supply SCALANCE X101-1LD...................................................................................... 4-30
Figure 4-16
Connector pinout...................................................................................................................... 4-30
Figure 4-17
Signaling contact SCALANCE X101-1LD ............................................................................... 4-31
Figure 4-18
Connector pinout...................................................................................................................... 4-31
Figure 4-19
SCALANCE X101-1POF.......................................................................................................... 4-39
Figure 4-20
RJ-45 connector pinout............................................................................................................ 4-40
Figure 4-21
Power supply SCALANCE X101-1POF................................................................................... 4-42
Figure 4-22
Connector pinout...................................................................................................................... 4-42
Figure 4-23
Signaling contact SCALANCE X101-1POF ............................................................................. 4-43
Figure 4-24
Connector pinout...................................................................................................................... 4-43
Figure 5-1
Installation on a DIN rail (35 mm) .............................................................................................. 5-2
Figure 5-2
Removing from a DIN rail (35 mm) ............................................................................................ 5-3
Figure 5-3
Installation on a SIMATIC S7-300 DIN rail ................................................................................ 5-4
Figure 5-4
IE FC RJ-45 plug 180 ................................................................................................................ 5-6
Figure 5-5
Inserting the IE FC RJ-45 plug 180 ........................................................................................... 5-7
Figure 5-6
Unlatching the RJ-45 plug.......................................................................................................... 5-8
Figure 8-1
Dimension drawing .................................................................................................................... 8-1
Figure 8-2
Dimension drawing / Side view .................................................................................................. 8-2
Figure 8-3
Bending radii .............................................................................................................................. 8-3
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
v
1
Preface 1.1 Preface Purpose of the Commissioning Manual
This commissioning manual supports you when commissioning networks with the media converters of the SCALANCE X-100 series.
Validity of this Commissioning Manual This commissioning manual is valid for the following devices: SIMATIC NET SCALANCE X101-1 SIMATIC NET SCALANCE X101-1FL SIMATIC NET SCALANCE X101-1LD SIMATIC NET SCALANCE X101-1POF
6GK5101-1BB00-2AA3 6GK5101-1BY00-2AA3 6GK5101-1BC00-2AA3 6GK5101-1BH00-2AA3
Further Documentation The “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” manual contains additional information on other SIMATIC NET products that you can operate along with the media converters of the SCALANCE X-100 series in an Industrial Ethernet network.
Finding information To help you to find the information you require more quickly, the manual includes not only the table of contents but also the following sections in the Appendix: • Glossary • Index
Audience This commissioning manual is intended for persons involved in the commissioning of networks with the media converters of the SCALANCE X-100 series.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
1-1
Preface 1.1 Preface
Standards and Approvals The media converters of the SCALANCE X-100 series meet the requirements for the CE mark. For detailed information please refer to the chapter “ Notes on the CE Mark” of this commissioning manual. The media converters of the SCALANCE X-100 series meet the requirements for the UL , CTick , FM and ATEX marks . For detailed information please refer to the technical specifications of the respective media converter in the “Approvals” heading of this commissioning manual.
1-2
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Introduction
2
2.1 Introduction This chapter provides you with an overview of the functions of the unmanaged Industrial Ethernet media converters of the SCALANCE X-100 series.
What Is Possible? The media converters of the SCALANCE X-100 series enable the cost-effective installation of Industrial Ethernet bus and star structures with media transitions.
Note The passive use of two identical SCALANCE X-100 media converters1 in cascade connection (series connection) within a redundant ring is possible. The media converters act as a “ line section” . A simple, passive coupling of two rings is also possible. Compare chapter 3.2 Coupling of Network Segments.
Note The requirements of EN61000-4-5, surge test on power supply lines, are met only when a Blitzductor VT AD 24V type no. 918 402 is used Manufacturer: DEHN+SÖHNE GmbH + Co. KG Hans Dehn Str.1 Postfach 1640 D-92306 Neumarkt, Germany
1
Only SCALANCE X101-1 or SCALANCE X101-1LD or SCALANCE X101-1POF
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
2-1
Introduction 2.1 Introduction
Warning When used under hazardous conditions (zone 2), the media converter of the SCALANCE X100 series must be installed in an enclosure. In the scope of ATEX100a (EN 60079-15), this enclosure must at least comply with IP54 according to EN 60529. WARNING – EXPLOSION HAZARD: DO NOT DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT.
:
Note The specified approvals apply only when the corresponding mark is printed on the product.
2-2
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Network Topologies
3
3.1 Network Topologies Which network topologies can be implemented? With an Industrial Ethernet media converter of the SCALANCE X-100 series, bus and star topologies can be implemented. In addition, it is possible to couple rings and the usage of two identical media converters2 in a ring network. Please compare in chapter 4 Product Characteristics, subsection Cascade, of the concerning media converter.
Bus Topology
Figure 3-1
2
Electrical/optical bus topology with SCALANCE X101-1
Only SCALANCE X101-1 or SCALANCE X101-1LD or SCALANCE X101-1POF
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
3-1
Network Topologies 3.1 Network Topologies
Star Topology
Figure 3-2
Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a extension for Optical Lines with SCALANCE X101-1LD Media converter
Ring Topology See in chapter 4 Product Characteristics, subsection Cascade, of the concerning media converter.
Figure 3-3
3-2
Electrical Ring, Example with SCALANCE X204IRT as Redundancy Manager, X208 and conversion to a Optical Line with SCALANCE X101-1 or X101-1LD Media converter
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Network Topologies 3.1 Network Topologies
Figure 3-4
Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a extension for Optical Lines with SCALANCE X101-1LD Media converter
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
3-3
Network Topologies 3.2 Coupling of Network Segments
3.2 Coupling of Network Segments The coupling of two ring network topologies using two SCALANCE X101-1 media converters shown here as an example is only possible indirectly via nodes with redundancy capability (e.g. SCALANCE X-400). This applies to all media converters of the SCALANCE X-100 series.
Figure 3-5
3-4
Stand-By Coupling of two Redundant Rings via Master / Slave Concept of SCALANCE X-400. Coupling is realized with SCALANCE X101-1 or X101-1LD Media converter
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4
Product Characteristics 4.1 Overview Table 4-1
Overview of the product characteristics
Characteristics
Device type X101-1
X101-1FL
X101-1LD
X101-1POF
SIMATIC environment
+
+
+
+
Diagnostics LED
+
+
+
+
24V DC
+
+
+
+
Compact housing 40mm (securing collar, etc.)
+
+
+
+
2x 24 V DC
+
+
+
+
Signaling contact + on-site operation
+
+
+
+
Diagnostics: Web, SNMP, PROFINET
-
-
-
-
C-PLUG
-
-
-
-
Ring redundancy with RM
-
-
-
-
Ring redundancy passive
+
+
+
+
Standby redundancy
-
-
-
-
IRT capability
-
-
-
-
Fast learning
-
-
-
-
Passive listening
-
-
-
-
Log table
-
-
-
-
SNTP + SICLOCK
-
-
-
-
Cut through
+
+
+
+
Table 4-2
Overview of the possible attachments
Cable type/transceiver wavelength
Device type, interface X101-1
X101-1FL
X101-1LD
X101-1POF
TP(RJ-45)
1
1
1
1
Fiber multimode (BFOC) / 1300nm
1
Fiber multimode (BFOC) / 820nm Fiber long distance monomode (BFOC) /1310nm Plastic optical fiber (SC-RJ) / 650nm
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
1 1 1
4-1
Product Characteristics 4.2 SCALANCE X101-1
4.2 SCALANCE X101-1
4.2.1
SCALANCE X101-1 Components Supplied
What ships with the media converter? • SCALANCE X101-1 device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) – PST tool (only for devices of the SCALANCE X-200 product line) – GSD file (only for devices of the SCALANCE X-200 product line) – SNMP OPC profile (only for devices of the SCALANCE X-200 product line)
4.2.2
SCALANCE X101-1 Unpacking and Checking
Unpacking, Checking 1.
Make sure that the package is complete.
2.
Check all parts for transport damage.
Warning Do not use any parts that show evidence of damage!
Warning If the SCALANCE X101-1 device is operated in ambient temperatures between 55°C60°C, the temperature of the device housing may be higher than 70°C. The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 55°C-60°C.
4-2
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.2 SCALANCE X101-1
4.2.3
SCALANCE X101-1 Product Characteristics
Possible Attachments The SCALANCE X101-1 media converter features an RJ-45 jack and a BFOC port for the connection of DTEs or other network segments.
Note The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket
Figure 4-1
SCALANCE X101-1
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-3
Product Characteristics 4.2 SCALANCE X101-1
4.2.4
SCALANCE X101-1 TP Port
Connector Pinout RJ-45 jack
Figure 4-2
RJ-45 connector pinout
Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
NC NC TDNC NC TD+ RDRD+
On SCALANCE X101-1, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP port. Depending on the cable type, a total cable length of up to 100 m is permitted between two devices with the IE FC cables and IE FC RJ-45 plug 180.
Autonegotiation Autonegotiation means the automatic detection of the functionality of the port at the opposite end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the port of a partner device allowing automatic configuration of different types of device. With autonegotiation, two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality.
4-4
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.2 SCALANCE X101-1
Note Devices not supporting autonegotiation must be set to 100 Mbps / half duplex.
MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user. All media converters of the SCALANCE X-100 series support the MDI / MDIX autocrossover function.
4.2.5
SCALANCE X101-1 FO Port
Transmission Speed The transmission rate of the optical Fast Ethernet port is 100 Mbps.
Transmission Mode The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be selected.
Transmission Medium The data are transferred over multimode fiber-optic cable (FOC). The transceiver wavelength is 1300 nm. Multimode fiber-optic cables are used with a core diameter of 50 or 62.5 µm, the light source is an LED. The outer diameter of the FOC is 125 µm.
Range The maximum transmission range (segment length) is 3 km if the signal attenuation of the FOC is ≤ 1 dB/km at 1300 nm.
Connectors The cables are connected to BFOC sockets.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-5
Product Characteristics 4.2 SCALANCE X101-1
4.2.6
SCALANCE X101-1 Power Supply and Signaling Contact
Power Supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When using a redundant power supply, the power supply unit with the higher output voltage supplies SCALANCE X101-1 alone. The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup.
Figure 4-3
Power supply SCALANCE X101-1
Figure 4-4 Connector pinout Pin number Pinout Pin 1 Pin 2 Pin 1 Pin 2
L1+ M1 M2 L2+
(+18 - 32V DC) (ground) (ground) (+18 - 32V DC)
Warning The SCALANCE X101-1 device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1 must comply with NEC Class 2 (voltage range 18-32 V, current requirement 200 mA). If the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements. The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV), DC 24 V). Never connect SCALANCE X101-1 to AC voltage. Never operate SCALANCE X101-1 with DC voltage higher than 32 V DC.
4-6
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.2 SCALANCE X101-1
Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation.
Figure 4-5 Signaling contact SCALANCE X101-1
Figure 4-6
Connector pinout
Pin number
Pinout
Pin 1 Pin 2
F1 F2
The following errors/faults can be signaled by the signaling contact: • The failure of a link at one of the two monitored ports. • The failure of one of the two redundant power supply units. Connecting or disconnecting a communication node at an unmonitored port does not cause an error message. The signaling contact remains activated until the error/fault is eliminated or until the current status is applied as new desired status by the button. When turning off the device, the signaling contact is always activated (open).
4.2.7
SCALANCE X101-1 Button
What is the function of the button? Using the button, you can display and modify the set fault mask and set the transparent link mode (see chapter 4.2.8). After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds. The LED of the monitored port flashes at a frequency of 5 Hz. Keep the button pressed to modify the fault mask. After another 3 seconds, the current link status of the ports and the indicator of the power supply LEDs are displayed at a flashing frequency of 2.5 Hz. Keep the button pressed. After another 3 seconds, this status is applied as new fault mask and saved. The now monitored ports are indicated by the permanently lit LEDs until the button is released. As long as the LEDs are still flashing, the saving can be canceled by releasing the button.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-7
Product Characteristics 4.2 SCALANCE X101-1 If an empty fault mask (no port is monitored) is set or is to be set, the 2 port LEDs flash alternatingly. Simultaneously with the fault mask, the monitoring of the connected power supply is set. The existence of the two power supply units is only monitored if both power supplies are connected during saving the fault mask. The failure of the link on a monitored port or of one of the monitored power supplies is indicated by the illuminated red error LED. The signaling contact is opened simultaneously.
Note The factory default is no port monitoring but monitoring of the power supply L1+/M1. If necessary, error LED and signaling contact have to be cleared by pressing the button for an appropriate period or the feeding point has to be changed when connecting only one power supply to L2+/M2.
The setting remains after turning off/on.
4.2.8
Cascade Connection of two Media Converters If you cascade two media converters, i.e. connect the converters via the FO port, it is mandatory to previously activate this operating mode using the button. Keep the button pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated by the illuminated “TL” (transparent link) LED. Again press the button for 1-2 seconds to exit this operating mode. The “TL” LED is extinguished. Important notes:
4-8
•
Max. two media converters can be cascaded
•
mixed cascading with SCALANCE X-100 Media converter and OMC-Media converter is not possible
•
The cascade connection is only permitted via the connection of the FO ports!
•
It is mandatory that a cascade connection is set at both (!) media converters using the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur.
•
The setting remains after turning on/off.
•
The factory setting is “ stand-alone mode” , i.e. no cascade is set
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.2 SCALANCE X101-1
4.2.9
SCALANCE X101-1 Displays
Fault indicator (red LED) ) Status
Meaning
Lit red
SCALANCE X101-1 detects an error. Simultaneously the signaling contact opens. The following errors are detected: 1. Link down event at a monitored port. 2. Failure of the supply voltage or supply voltage less than 14 V of one of the two redundant power supplies. See also note in chapter 4.2.7
Not lit
No error was detected by SCALANCE X101-1.
Power indicator (green LED) The status of the power supply is indicated by a green LED: Status
Meaning
Lit green
Power supply L1 or L2 are connected.
Not lit
Power supply L1 and L2 is not connected or L1 and L2 <14 V Comment: If the green LED is not lit, no other signal LED is lit.
Port status indicator (green/yellow LEDs) ) The status of the ports is indicated by 2 LEDs: Status
Meaning
Port 1: LED lit green
link exists, no data reception at TP port
Port 2: LED lit green
link exists, no data reception at FOC
Port 1: LED lit yellow
link exists, data received at TP port
Port 2: LED lit yellow
link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow
Setting or display of the fault mask
Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time. In transparent link mode the link state is also recognized and indicated by the optical port(P2) without a link at the port P1 (see chapter 4.2.8).
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-9
Product Characteristics 4.2 SCALANCE X101-1
Transparent link display (green LED) “TL” (transparent link) LED: Status
Meaning
Lit green
Transparent link parameterized.
Not lit
Stand-alone mode. DTEs are connected to both ports of the media converter (no cascading)
See chapter 4.2.8 "Important notes"!
4-10
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.2 SCALANCE X101-1
4.2.10
SCALANCE X101-1 Technical Specifications
Technical Specifications of SCALANCE X101-1 Ports Attachment of DTEs or network components over twisted pair
1xRJ-45 socket with MDI-X pinning 100 Mbps full duplex
Connection of further network components over FOC
2 BFOC sockets (100 Mbps, full duplex to 100 BaseFX)
Connector for power supply
1x4-pin plug-in terminal block
Connector for signaling contact
1x2-pin plug-in terminal block
Electrical Data Power supply
2 x DC 24 V (DC 18 - 32 V) safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.)
3W
Current consumption at rated voltage (typ.)
120 mA
Minimum rated current of the power supply
170 mA
Overvoltage protection at input
PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths Network span parameter/TP cable length 0 – 100 m
0 – 85 m
Network span parameter/FO cable length 0 - 3000 m
IE FC TP standard cable with IE FC RJ-45 plug 180 or IE FC outlet RJ-45 with IE FC TP standard cable (0 - 90 m) + 10 m TP cord IE FC TP marine/trailing/flexible with IE FC RJ-45 plug 180 or IE FC TP marine/trailing/flexible (0 – 75 m) + 10 m TP cord over IE FC outlet RJ-45 Glass FOC 62.5/125 µm or 50/125 µm glass fiber; ≤ 1 dB/km at 1300 nm; 1200 MHz x km at 1300 nm; 6 dB max. permitted FO cable attenuation with 3 dB link power margin Bending radius once without tensile force: 100 mm bending radius repeatedly with tensile force: 150 mm
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-11
Product Characteristics 4.2 SCALANCE X101-1
Permitted Environmental Conditions / EMC Operating temperature
-10°C to +60°C
Storage/transport temperature
-40°C to +80°C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature
RF interference level
EN 61000-6-3
Noise immunity
EN 61000-6-2
Degree of protection
IP30
Approvals c-UL-us
UL 60950 CSA C22.2 No. 60950
c-Ul-us for hazardous locations 3
UL 1604, UL 2279Pt.15 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. CL. 1, Zone2, AEx nC IIC T..
FM 3
FM 3611 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. Ta: ..
C-Tick
AS/NZS 2064 (Class A). EN 61000-6-2, EN 61000-6-4
CE ATEX Zone 2
3
EN60079-15:2005 EN60079-0:2006 II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X
MTBF MTBF
134 years
Construction
3
Dimensions (W x H x D) in mm
40 x 125 x 124
Weight in g
550
Installation options
DIN rail S7-300 DIN rail Wall mounting
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
4-12
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.2 SCALANCE X101-1
Order Numbers SCALANCE X101-1
6GK5101-1BB00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool
6GK1901-1GA00
IE FC blade cassettes
6GK1901-1GB00
IE FC TP standard cable GP
6XV1840 2AH10
IE FC TP trailing cable
6XV1840-3AH10
IE FC TP marine cable
6XV1840-4AH10
IE FC TP trailing cable GP
6XV1870-2D
IE FC TP flexible cable GP
6XV1870-2B
IE FC RJ-45 plug 180 pack of 1
6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10
6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50
6GK1 901-1BB10-2AE0
Note The number of SCALANCE X Industrial Ethernet devices connected in a line influences the frame propagation time. When a frame passes through the media converters of the SCALANCE X-100 series, it is typically delayed by approx. 8µs by the “Cut Through” function of the internal switch - At a network load of 100% these times can increase system-dependently (max. 140 µs)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-13
Product Characteristics 4.3 SCALANCE X101-1FL
4.3 SCALANCE X101-1FL
4.3.1
SCALANCE X101-1FL Components Supplied
What ships with the media converter? • SCALANCE X101-1FL device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) – PST tool (only for devices of the SCALANCE X-200 product line) – GSD file (only for devices of the SCALANCE X-200 product line) – SNMP OPC profile (only for devices of the SCALANCE X-200 product line)
4.3.2
SCALANCE X101-1FL Unpacking and Checking
Unpacking, Checking 1.
Make sure that the package is complete.
2.
Check all parts for transport damage.
Warning Do not use any parts that show evidence of damage!
Warning If the SCALANCE X101-1FL device is operated in ambient temperatures between 55°C60°C, the temperature of the device housing may be higher than 70°C. The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 55°C-60°C .
4-14
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.3 SCALANCE X101-1FL
4.3.3
SCALANCE X101-1FL Product Characteristics
Possible Attachments The SCALANCE X101-1FL media converter features an RJ-45 jack and a BFOC port for the connection of DTEs or other network segments.
Note The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket
Figure 4-7
SCALANCE X101-1FL
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-15
Product Characteristics 4.3 SCALANCE X101-1FL
4.3.4
SCALANCE X101-1FL TP Port
Connector Pinout RJ-45 jack
Figure 4-8
RJ-45 connector pinout
Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
NC NC TDNC NC TD+ RDRD+
On SCALANCE X101-1FL, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP port. Depending on the cable type, a total cable length of up to 100 m is permitted between two devices with the IE FC cables and IE FC RJ-45 plug 180.
Note The SCALANCE X101-1FL works with a fixed transmission speed of 10 Mbps in half duplex. Devices not supporting autonegotiation must be set to 10 Mbps half duplex.
4-16
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.3 SCALANCE X101-1FL
MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user. All media converters of the SCALANCE X-100 series support the MDI / MDIX autocrossover function.
Note Autopolarity is not support by the SCALANCE X101-1FL.
4.3.5
SCALANCE X101-1FL FO Port
Transmission Speed The transmission rate of the optical Ethernet port is 10 Mbps.
Note The SCALANCE X101-1FL works with a fixed transmission speed of 10 Mbps in half duplex.
Transmission Mode The transmission mode for 10Base-FL is specified in the IEEE 802.3 standard. Since the half duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be applied.
Transmission Medium The data are transferred over multimode fiber-optic cable (FOC). The transceiver wavelength is 820 nm. Multimode fiber-optic cables are used with a core diameter of 50 or 62.5 µm, the light source is an LED. The outer diameter of the FOC is 125 µm.
Range The maximum transmission range (segment length) is 3 km if the signal attenuation of the FOC is ≤ 3 dB/km at 850 nm. Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-17
Product Characteristics 4.3 SCALANCE X101-1FL
Connectors The cables are connected to BFOC sockets.
4.3.6
SCALANCE X101-1FL Power Supply and Signaling Contact
Power Supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When using a redundant power supply, the power supply unit with the higher output voltage supplies SCALANCE X101-1FL alone. The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup.
Figure 4-9
Power supply SCALANCE X101-1FL
Figure 4-10
Connector pinout
Pin number Pinout Pin 1 Pin 2 Pin 1 Pin 2
L1+ M1 M2 L2+
(+18 - 32V DC) (ground) (ground) (+18 - 32V DC)
Warning The SCALANCE X101-1FL device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1FL must comply with NEC Class 2 (voltage range 18-32 V, current requirement 200 mA). If the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements. The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV), DC 24 V). Never connect SCALANCE X101-1FL to AC voltage. Never operate SCALANCE X101-1FL with DC voltage higher than 32 V DC.
4-18
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.3 SCALANCE X101-1FL
Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation.
Figure 4-11
Signaling contact SCALANCE X101-1FL
Figure 4-12
Connector pinout
Pin number
Pinout
Pin 1 Pin 2
F1 F2
The following errors/faults can be signaled by the signaling contact: • The failure of a link at one of the two monitored ports. • The failure of one of the two redundant power supply units. Connecting or disconnecting a communication node at an unmonitored port does not cause an error message. The signaling contact remains activated until the error/fault is eliminated or until the current status is applied as new desired status by the button. When turning off the device, the signaling contact is always activated (open).
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-19
Product Characteristics 4.3 SCALANCE X101-1FL
4.3.7
SCALANCE X101-1FL Button
What is the function of the button? Using the button , you can display and modify the set fault mask. After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds. The LED of the monitored port flashes at a frequency of 5 Hz. Keep the button pressed to modify the fault mask. After another 3 seconds, the current link status of the ports and the indicator of the power supply LEDs are displayed at a flashing frequency of 2.5 Hz. Keep the button pressed. After another 3 seconds, this status is applied as new fault mask and saved. The now monitored ports are indicated by the permanently lit LEDs until the button is released. As long as the LEDs are still flashing, the saving can be canceled by releasing the button. If an empty fault mask (no port is monitored) is set or is to be set, the 2 port LEDs flash alternatingly. Simultaneously with the fault mask, the monitoring of the connected power supply is set. The existence of the two power supply units is only monitored if both power supplies are connected during saving the fault mask. The failure of the link on a monitored port or of one of the monitored power supplies is indicated by the illuminated red error LED. The signaling contact is opened simultaneously.
Note The factory default is no port monitoring but monitoring of the power supply L1+/M1. If necessary, error LED and signaling contact have to be cleared by pressing the button for an appropriate period or the feeding point has to be changed when connecting only one power supply to L2+/M2.
The setting remains after turning off/on.
4.3.8
Cascade Connection of two Media Converters If you cascade two media converters, i.e. connect the converters via the FO port, it is mandatory to previously activate this operating mode using the button. Keep the button pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated by the illuminated “TL” (transparent link) LED. Again press the button for 1-2 seconds to exit this operating mode. The “TL” LED is extinguished. Important notes:
4-20
•
Max. two media converters can be cascaded
•
mixed cascading with SCALANCE X-100 Media converter and OMC-Media converter is not possible
•
The cascade connection is only permitted via the connection of the FO ports!
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.3 SCALANCE X101-1FL
4.3.9
•
It is mandatory that a cascade connection is set at both (!) media converters using the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur.
•
The setting remains after turning on/off.
•
The factory setting is “ stand-alone mode” , i.e. no cascade is set
SCALANCE X101-1FL Displays
Fault indicator (red LED) Status
Meaning
Lit red
SCALANCE X101-1FL detects an error. Simultaneously the signaling contact opens. The following errors are detected: 1. Link down event at a monitored port. 2. Failure of the supply voltage or supply voltage less than 14 V of one of the two redundant power supplies. See also note in chapter 4.3.7
Not lit
No error was detected by SCALANCE X101-1FL.
Power indicator (green LED) The status of the power supply is indicated by a green LED: Status
Meaning
Lit green
Power supply L1 or L2 are connected.
Not lit
Power supply L1 and or L2 is not connected or L1 and L2 <14 V Comment: If the green LED is not lit, no other signal LED is lit.
Port status indicator (green/yellow LEDs The status of the ports is indicated by 2 LEDs: Status
Meaning
Port 1: LED lit green
link exists, no data reception at TP port
Port 2: LED lit green
link exists, no data reception at FOC
Port 1: LED lit yellow
link exists, data received at TP port
Port 2: LED lit yellow
link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow
Setting or display of the fault mask
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-21
Product Characteristics 4.3 SCALANCE X101-1FL
Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time.
Transparent link display (green LED) “TL” (transparent link) LED: The TL LED has no function. Status
Meaning
Not lit
Stand-alone mode. DTEs are connected to both ports of the media converter (no cascading)
A direct cascade connection of two SCALANCE X101-1FL media converters is not possible, thus no transparent link.
4-22
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.3 SCALANCE X101-1FL
4.3.10
SCALANCE X101-1FL Technical Specifications
SCALANCE X101-1FL Technical Specifications Ports Attachment of DTEs or network components over twisted pair
1xRJ-45 socket with MDI-X pinning 10 Mbps half duplex
Connection of further network components over FOC
2 BFOC sockets (10 Mbps, half duplex to 10 BaseFL)
Connector for power supply
1x4-pin plug-in terminal block
Connector for signaling contact
1x2-pin plug-in terminal block
Electrical Data Power supply
2 x DC 24 V (DC 18 - 32 V) safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.)
3W
Current consumption at rated voltage (typ.)
120 mA
Minimum rated current of the power supply
200 mA
Overvoltage protection at input
PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths Network span parameter/TP cable length 0 – 100 m
0 – 85 m
Network span parameter/FO cable length 0 - 3000 m
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
IE FC TP standard cable with IE FC RJ-45 plug 180 or IE FC outlet RJ-45 with IE FC TP standard cable (0 - 90 m) + 10 m TP cord IE FC TP marine/trailing/flexible with IE FC RJ-45 plug 180 or IE FC TP marine/trailing/flexible (0 – 75 m) + 10 m TP cord over IE FC outlet RJ-45 Glass FOC 62.5/125 µm or 50/125 µm glass fiber; ≤ 3 dB/km at 850 nm; 600 MHz x km at 850 nm; 12 dB max. permitted FO cable attenuation with 3 dB link power margin Bending radius once without tensile force: 100 mm bending radius repeatedly with tensile force: 150 mm
4-23
Product Characteristics 4.3 SCALANCE X101-1FL
Permitted Environmental Conditions / EMC Operating temperature
-10°C to +60°C
Storage/transport temperature
-40°C to +80°C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature
RF interference level
EN 61000-6-3
Noise immunity
EN 61000-6-2
Degree of protection
IP30
Approvals c-UL-us
UL 60950 CSA C22.2 No. 60950
c-Ul-us for hazardous locations 4
UL 1604, UL 2279Pt.15 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. CL. 1, Zone2, AEx nC IIC T..
FM 4
FM 3611 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. Ta: ..
C-Tick
AS/NZS 2064 (Class A).
CE
EN 61000-6-2, EN 61000-6-4
ATEX Zone 2 4
EN60079-15:2005 EN60079-0:2006 II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X
MTBF MTBF
134 years
Construction
4
Dimensions (W x H x D) in mm
40 x 125 x 124
Weight in g
550
Installation options
DIN rail S7-300 DIN rail Wall mounting
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
4-24
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.3 SCALANCE X101-1FL
Order Numbers SCALANCE X101-1FL
6GK5101-1BY00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool
6GK1901-1GA00
IE FC blade cassettes
6GK1901-1GB00
IE FC TP standard cable GP
6XV1840 2AH10
IE FC TP trailing cable
6XV1840-3AH10
IE FC TP marine cable
6XV1840-4AH10
IE FC TP trailing cable GP
6XV1870-2D
IE FC TP flexible cable GP
6XV1870-2B
IE FC RJ-45 plug 180 pack of 1
6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10
6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50
6GK1 901-1BB10-2AE0
Note The number of SCALANCE X Industrial Ethernet devices connected in a line influences the frame propagation time. When a frame passes through the media converters of the SCALANCE X-100 series, it is typically delayed by approx. 40 µs by the “Cut Through” function of the internal switch - At a network load of 100%, these times can increase system-dependently (max. 180 µs)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-25
Product Characteristics 4.4 SCALANCE X101-1LD
4.4 SCALANCE X101-1LD
4.4.1
SCALANCE X101-1LD Components Supplied
What ships with the media converter? • SCALANCE X101-1LD device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) – PST tool (only for devices of the SCALANCE X-200 product line) – GSD file (only for devices of the SCALANCE X-200 product line) – SNMP OPC profile (only for devices of the SCALANCE X-200 product line)
4.4.2
SCALANCE X101-1LD Unpacking and Checking
Unpacking, Checking 1.
Make sure that the package is complete.
2.
Check all parts for transport damage.
Warning Do not use any parts that show evidence of damage!
Warning If the SCALANCE X101-1LD device is operated in ambient temperatures between 55°C60°C, the temperature of the device housing may be higher than 70°C. The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 55°C-60°C.
4-26
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.4 SCALANCE X101-1LD
4.4.3
SCALANCE X101-1LD Product Characteristics
Possible Attachments The media converter of SCALANCE X101-1LD features an RJ-45 jack and a BFOC port for the connection of DTEs or other network segments.
Note The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket
Figure 4-13
SCALANCE X101-1LD
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-27
Product Characteristics 4.4 SCALANCE X101-1LD
4.4.4
SCALANCE X101-1LD TP Port
Connector pinout RJ-45 jack
Figure 4-14
RJ-45 connector pinout
Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
NC NC TDNC NC TD+ RDRD+
On SCALANCE X101-1LD, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP port. Depending on the cable type, a total cable length of up to 100 m is permitted between two devices with the IE FC cables and IE FC RJ-45 plug 180.
Autonegotiation Autonegotiation means the automatic detection of the functionality of the port at the opposite end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the port of a partner device allowing automatic configuration of different types of device. With autonegotiation, two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality.
4-28
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.4 SCALANCE X101-1LD
Note Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex.
MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user. All media converters of the SCALANCE X-100 series support the MDI / MDIX autocrossover function.
4.4.5
SCALANCE X101-1LD FO Port
Transmission Speed The transmission rate of the optical Fast Ethernet port is 100 Mbps.
Transmission Mode The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be applied.
Transmission Medium The data are transferred over monomode fiber-optic cable (FOC). The transceiver wavelength is 1310 nm. Monomode fiber-optic cables are used with a core diameter of 10 µm. The outer diameter of the FOC is 125 µm.
Source The light source is an “eye-safe” Class1 laser with a wavelength of 1310 nm
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-29
Product Characteristics 4.4 SCALANCE X101-1LD
Range The maximum transmission range (segment length) is 26 km if the signal attenuation of the FOC is ≤ 0.5 dB/km.
Connectors The cables are connected to BFOC sockets.
4.4.6
SCALANCE X101-1LD Power Supply and Signaling Contact
Power Supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When using a redundant power supply, the power supply unit with the higher output voltage supplies SCALANCE X101-1LD alone. The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup.
Figure 4-15
Power supply SCALANCE X101-1LD
Figure 4-16
Connector pinout
Pin number Pinout Pin 1 Pin 2 Pin 1 Pin 2
4-30
L1+ M1 M2 L2+
(+18 - 32V DC) (ground) (ground) (+18 - 32V DC)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.4 SCALANCE X101-1LD
Warning The SCALANCE X101-1LD device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1LD must comply with NEC Class 2 (voltage range 18-32 V, current requirement 200 mA). If the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements. The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV), DC 24 V). Never connect SCALANCE X101-1LD to AC voltage. Never operate SCALANCE X101-1LD with DC voltage higher than 32 V DC.
Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation.
Figure 4-17
Signaling contact SCALANCE X101-1LD
Figure 4-18 Connector pinout Pin number
Pinout
Pin 1 Pin 2
F1 F2
The following errors/faults can be signaled by the signaling contact: • The failure of a link at one of the two monitored ports. • The failure of one of the two redundant power supply units. Connecting or disconnecting a communication node at an unmonitored port does not cause an error message. The signaling contact remains activated until the error/fault is eliminated or until the current status is applied as new desired status by the button. When turning off the device, the signaling contact is always activated (open).
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-31
Product Characteristics 4.4 SCALANCE X101-1LD
4.4.7
SCALANCE X101-1LD Button
What is the function of the button? Using the button , you can display and modify the set fault mask and set the transparent link mode (see chapter 4.4.8). After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds. The LED of the monitored port flashes at a frequency of 5 Hz. Keep the button pressed to modify the fault mask. After another 3 seconds, the current link status of the ports and the indicator of the power supply LEDs are displayed at a flashing frequency of 2.5 Hz. Keep the button pressed. After another 3 seconds, this status is applied as new fault mask and saved. The now monitored ports are indicated by the permanently lit LEDs until the button is released. As long as the LEDs are still flashing, the saving can be canceled by releasing the button. If an empty fault mask (no port is monitored) is set or is to be set, the 2 port LEDs flash alternatingly. Simultaneously with the fault mask, the monitoring of the connected power supply is set. The existence of the two power supply units is only monitored if both power supplies are connected during saving the fault mask. The failure of the link on a monitored port or of one of the monitored power supplies is indicated by the illuminated red error LED. The signaling contact is opened simultaneously.
Note The factory default is no port monitoring but monitoring of the power supply L1+/M1. If necessary, error LED and signaling contact have to be cleared by pressing the button for an appropriate period or the feeding point has to be changed when connecting only one power supply to L2+/M2.
The setting remains after turning off/on.
4.4.8
Cascade Connection of two Media Converters If you cascade two media converters, i.e. connect the converters via the FO port, it is mandatory to previously activate this operating mode using the button. Keep the button pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated by the illuminated “TL” (Transparent Link) LED. Again press the button for 1-2 seconds to exit this operating mode. The “TL” LED is extinguished. Important notes:
4-32
•
Max. two media converters can be cascaded
•
mixed cascading with SCALANCE X-100 Media converter and OMC-Media converter is not possible
•
The cascade connection is only permitted via the connection of the FO ports!
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.4 SCALANCE X101-1LD
4.4.9
•
It is mandatory that a cascade connection is set at both (!) media converters using the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur.
•
The setting remains after turning on/off.
•
The factory setting is “ stand-alone mode” , i.e. no cascade is set
SCALANCE X101-1LD Displays
Fault indicator (red LED) Status
Meaning
Lit red
SCALANCE X101-1LD detects an error. Simultaneously the signaling contact opens. The following errors are detected: 1. Link down event at a monitored port. 2. Failure of the supply voltage or supply voltage less than 14 V of one of the two redundant power supplies. See also note in chapter 4.4.7
Not lit
No error was detected by SCALANCE X101-1LD.
Power indicator (green LED) The status of the power supply is indicated by a green LED: Status
Meaning
Lit green
Power supply L1 or L2 are connected.
Not lit
Power supply L1 and or L2 is not connected or L1 and L2 <14 V Comment: If the green LED is not lit, no other signal LED is lit.
Port status indicator (green/yellow LEDs) The status of the ports is indicated by 2 LEDs: Status
Meaning
Port 1: LED lit green
link exists, no data reception at TP port
Port 2: LED lit green
link exists, no data reception at FOC
Port 1: LED lit yellow
link exists, data received at TP port
Port 2: LED lit yellow
link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow
Setting or display of the fault mask
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-33
Product Characteristics 4.4 SCALANCE X101-1LD
Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time. In transparent link mode the link state is also recognized and indicated by the optical port(P2) without a link at the port P1 (see chapter 4.4.8).
Transparent link display (green LED) “TL” (transparent link) LED: Status
Meaning
Lit green
Transparent link parameterized.
Not lit
Stand-alone mode. DTEs are connected to both ports of the media converter (no cascading)
See chapter 4.4.8 "Important notes"!
4-34
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.4 SCALANCE X101-1LD
4.4.10
SCALANCE X101-1LD Technical Specifications
SCALANCE X101-1LD Technical Specifications Ports Attachment of DTEs or network components over twisted pair
1xRJ-45 socket with MDI-X pinning 100 Mbps full duplex
Connection of further network components over FOC
2 BFOC sockets (100 Mbps, full duplex to 100 BaseFX)
Connector for power supply
1x4-pin plug-in terminal block
Connector for signaling contact
1x2-pin plug-in terminal block
Electrical Data Power supply
2 x DC 24 V (DC 18 - 32 V) safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.)
3W
Current consumption at rated voltage (typ.)
120 mA
Minimum rated current of the power supply
200 mA
Overvoltage protection at input
PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths Network span parameter/TP cable length 0 – 100 m
0 – 85 m
Network span parameter/FO cable length 0 – 26.000 m
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
IE FC TP standard cable with IE FC RJ-45 plug 180 or IE FC outlet RJ-45 with IE FC TP standard cable (0 - 90 m) + 10 m TP cord IE FC TP marine/trailing/flexible with IE FC RJ-45 plug 180 or IE FC TP marine/trailing/flexible (0 – 75 m) + 10 m TP cord over IE FC outlet RJ-45 Glass FOC 10/125 µm single mode fiber; ≤ 0.5 dB/km at 1300 nm; 13 dB max. permitted FO cable attenuation with 2 dB link power margin Bending radius once without tensile force: 100 mm bending radius repeatedly with tensile force: 150 mm
4-35
Product Characteristics 4.4 SCALANCE X101-1LD
Permitted Environmental Conditions / EMC Operating temperature
-10°C to +60°C
Storage/transport temperature
-40°C to +80°C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature
RF interference level
EN 61000-6-4
Noise immunity
EN 61000-6-2
Degree of protection
IP30
Approvals c-UL-us
UL 60950 CSA C22.2 No. 60950
c-Ul-us for hazardous locations 5
UL 1604, UL 2279Pt.15 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. CL. 1, Zone2, AEx nC IIC T..
FM 5
FM 3611 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. Ta: ..
C-Tick
AS/NZS 2064 (Class A). EN 61000-6-2, EN 61000-6-4
CE ATEX Zone 2
5
EN60079-15:2005 EN60079-0:2006 II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X
MTBF MTBF
134 years
Construction Dimensions (W x H x D) in mm
5
40 x 125 x 124
Weight in g
550
Installation options
DIN rail S7-300 DIN rail Wall mounting
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
4-36
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.4 SCALANCE X101-1LD
Order Numbers SCALANCE X101-1LD
6GK5101-1BC00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool
6GK1901-1GA00
IE FC blade cassettes
6GK1901-1GB00
IE FC TP standard cable GP
6XV1840 2AH10
IE FC TP trailing cable
6XV1840-3AH10
IE FC TP marine cable
6XV1840-4AH10
IE FC TP trailing cable GP
6XV1870-2D
IE FC TP flexible cable GP
6XV1870-2B
IE FC RJ-45 plug 180 pack of 1
6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10
6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50
6GK1 901-1BB10-2AE0
Note The number of SCALANCE X Industrial Ethernet devices connected in a line influences the frame propagation time. When a frame passes through the media converters of the SCALANCE X-100 series, it is typically delayed by approx. 8µs by the “Cut Through” function of the internal switch - At a network load of 100% these times can increase system-dependently (max. 140 µs)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-37
Product Characteristics 4.5 SCALANCE X101-1POF
4.5 SCALANCE X101-1POF
4.5.1
SCALANCE X101-1POF Components Supplied
What ships with the media converter? • SCALANCE X101-1POF device • 2-pin plug-in terminal block • 4-pin plug-in terminal block • Product information • CD – Commissioning manual (this document) – PST tool (only for devices of the SCALANCE X-200 product line) – GSD file (only for devices of the SCALANCE X-200 product line) – SNMP OPC profile (only for devices of the SCALANCE X-200 product line)
4.5.2
SCALANCE X101-1POF Unpacking and Checking
Unpacking, Checking 1.
Make sure that the package is complete.
2.
Check all parts for transport damage.
Warning Do not use any parts that show evidence of damage!
Warning If the SCALANCE X101-1POF device is operated in ambient temperatures between 55°C-60°C, the temperature of the device housing may be higher than 70°C. The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 55°C-60°C.
4-38
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.5 SCALANCE X101-1POF
4.5.3
SCALANCE X101-1POF Product Characteristics
Possible Attachments The media converter of SCALANCE X101-1POF features an RJ-45 jack and an SC-RJ interface for the connection of DTEs or other network segments.
Figure 4-19
SCALANCE X101-1POF
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-39
Product Characteristics 4.5 SCALANCE X101-1POF
4.5.4
SCALANCE X101-1POF TP Port
Connector pinout RJ-45 jack
Figure 4-20
RJ-45 connector pinout
Pin number Pinout Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1
NC NC TDNC NC TD+ RDRD+
On SCALANCE X101-1POF, the twisted pair port is implemented as RJ-45 jack with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP port. Depending on the cable type, a total cable length of up to 100 m is permitted between two devices with the IE FC cables and IE FC RJ-45 plug 180.
Autonegotiation Autonegotiation means the automatic detection of the functionality of the port at the opposite end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the port of a partner device allowing automatic configuration of different types of device. With autonegotiation, two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality.
4-40
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.5 SCALANCE X101-1POF
Note Devices not supporting autonegotiation must be set to 100 Mbps / half duplex.
MDI /MDIX Autocrossover Function The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user. All media converters of the SCALANCE X-100 series support the MDI / MDIX autocrossover function.
4.5.5
SCALANCE X101-1POF FO Port
Transmission Speed The transmission rate of the optical Fast Ethernet port is 100 Mbps.
Transmission Mode The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be applied.
Transmission Medium The data are transferred over plastic optical fiber cable (FOC). The wavelength is 650 nm. Plastic optical fiber cables are used with a core diameter of 980 µm, the light source is an LED. The outer diameter of the FOC is 1000 µm.
Range The maximum transmission range (segment length) is 50 m if the signal attenuation of the FOC is ≤ 0.23 dB/m.
Connectors The cables are connected to SC-RJ sockets.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-41
Product Characteristics 4.5 SCALANCE X101-1POF
4.5.6
SCALANCE X101-1POF Power Supply and Signaling Contact
Power Supply The power supply is connected using a 4-pin plug-in terminal block. The power supply can be connected redundantly. Both inputs are isolated. There is no distribution of load. When using a redundant power supply, the power supply unit with the higher output voltage supplies SCALANCE X101-1POF alone. The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup.
Figure 4-21
Power supply SCALANCE X101-1POF
Figure 4-22
Connector pinout
Pin number Pinout Pin 1 Pin 2 Pin 1 Pin 2
L1+ M1 M2 L2+
(+18 - 32V DC) (ground) (ground) (+18 - 32V DC)
Warning The SCALANCE X101-1POF device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals. The power supply unit to supply SCALANCE X101-1POF must comply with NEC Class 2 (voltage range 18-32 V, current requirement 200 mA). If the device is connected to a redundant power supply (two separate power supplies), both must meet these requirements. The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low voltage (SELV), DC 24 V). Never connect SCALANCE X101-1POF to AC voltage. Never operate SCALANCE X101-1POF with DC voltage higher than 32 V DC.
4-42
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.5 SCALANCE X101-1POF
Signaling Contact The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact (optical relay contact) is a floating switch with which error/fault states are signaled by contact separation.
Figure 4-23
Signaling contact SCALANCE X101-1POF
Figure 4-24 Connector pinout Pin number
Pinout
Pin 1 Pin 2
F1 F2
The following errors/faults can be signaled by the signaling contact: • The failure of a link at one of the two monitored ports. • The failure of one of the two redundant power supply units. Connecting or disconnecting a communication node at an unmonitored port does not cause an error message. The signaling contact remains activated until the error/fault is eliminated or until the current status is applied as new desired status by the button. When turning off the device, the signaling contact is always activated (open).
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-43
Product Characteristics 4.5 SCALANCE X101-1POF
4.5.7
SCALANCE X101-1POF Button
What is the function of the button? Using the button , you can display and modify the set fault mask and set the transparent link mode (see chapter 4.5.8). After continuously pressing the button, the currently valid fault mask is displayed for approximately 3 seconds. The LED of the monitored port flashes at a frequency of 5 Hz. Keep the button pressed to modify the fault mask. After another 3 seconds, the current link status of the ports and the indicator of the power supply LEDs are displayed at a flashing frequency of 2.5 Hz. Keep the button pressed. After another 3 seconds, this status is applied as new fault mask and saved. The now monitored ports are indicated by the permanently lit LEDs until the button is released. As long as the LEDs are still flashing, the saving can be canceled by releasing the button. If an empty fault mask (no port is monitored) is set or is to be set, the 2 port LEDs flash alternatingly. Simultaneously with the fault mask, the monitoring of the connected power supply is set. The existence of the two power supply units is only monitored if both power supplies are connected during saving the fault mask. The failure of the link on a monitored port or of one of the monitored power supplies is indicated by the illuminated red error LED. The signaling contact is opened simultaneously.
Note The factory default is no port monitoring but monitoring of the power supply L1+/M1. If necessary, error LED and signaling contact have to be cleared by pressing the button for an appropriate period or the feeding point has to be changed when connecting only one power supply to L2+/M2.
The setting remains after turning off/on.
4.5.8
Cascade Connection of two Media Converters If you cascade two media converters, i.e. connect the converters via the FO port, it is mandatory to previously activate this operating mode using the button. Keep the button pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated by the illuminated “TL” (Transparent Link) LED. Again press the button for 1-2 seconds to exit this operating mode. The “TL” LED is extinguished. Important notes:
4-44
•
Max. two media converters can be cascaded
•
mixed cascading with SCALANCE X-100 Media converter and OMC-Media converter is not possible
•
The cascade connection is only permitted via the connection of the FO ports!
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.5 SCALANCE X101-1POF
4.5.9
•
It is mandatory that a cascade connection is set at both (!) media converters using the button (“ TL” LED must be illuminated). If this is not done, malfunctions can occur.
•
The setting remains after turning on/off.
•
The factory setting is “ stand-alone mode” , i.e. no cascade is set
SCALANCE X101-1POF Displays
Fault indicator (red LED) Status
Meaning
Lit red
SCALANCE X101-1POF detects an error. Simultaneously the signaling contact opens. The following errors are detected: 1. Link down event at a monitored port. 2. Failure of the supply voltage or supply voltage less than 14 V of one of the two redundant power supplies. See also note in chapter.4.5.7
Not lit
No error was detected by SCALANCE X101-1POF.
Power indicator (green LED) The status of the power supply is indicated by a green LED: Status
Meaning
Lit green
Power supply L1 or L2 are connected.
Not lit
Power supply L1 and or L2 is not connected or L1 and L2 <14 V Comment: If the green LED is not lit, no other signal LED is lit.
Port status indicator (green/yellow LEDs) The status of the ports is indicated by 2 LEDs: Status
Meaning
Port 1: LED lit green
link exists, no data reception at TP port
Port 2: LED lit green
link exists, no data reception at FOC
Port 1: LED lit yellow
link exists, data received at TP port
Port 2: LED lit yellow
link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow
Setting or display of the fault mask
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-45
Product Characteristics 4.5 SCALANCE X101-1POF
Note The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if both ports have link at the same time. In transparent link mode the link state is also recognized and indicated by the optical port(P2) without a link at the port P1 (see chapter 4.5.8).
Transparent link display (green LED) “ TL” (transparent link) LED: Status
Meaning
Lit green
Transparent link parameterized.
Not lit
Stand-alone mode. DTEs are connected to both ports of the media converter (no cascading)
See chapter 4.5.8 "Important notes"!
4-46
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.5 SCALANCE X101-1POF
4.5.10
SCALANCE X101-1POF Technical Specifications
SCALANCE X101-1POF Technical Specifications Ports Attachment of DTEs or network components over twisted pair
1xRJ-45 socket with MDI-X pinning 100 Mbps full duplex
Connection of further network components over FOC
2 SC-RJ sockets (100 Mbps, full duplex to 100 BaseFX)
Connector for power supply
1x4-pin plug-in terminal block
Connector for signaling contact
1x2-pin plug-in terminal block
Electrical Data Power supply
2 x DC 24 V (DC 18 - 32 V) safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.)
3W
Current consumption at rated voltage (typ.)
120 mA
Minimum rated current of the power supply
200 mA
Overvoltage protection at input
PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths Network span parameter/TP cable length 0 – 100 m
0 – 85 m
Network span parameter/FO cable length 0 - 50 m
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
IE FC TP standard cable with IE FC RJ-45 plug 180 or IE FC outlet RJ-45 with IE FC TP standard cable (0 - 90 m) + 10 m TP cord IE FC TP marine/trailing/flexible with IE FC RJ-45 plug 180 or IE FC TP marine/trailing/flexible (0 – 75 m) + 10 m TP cord over IE FC outlet RJ-45 Plastic optical fiber cable 980/1000 µm POF; ≤ 230 dB/km at 660 nm; 11.5 dB max. permitted FO cable attenuation with 3 dB link power margin Bending radius once without tensile force: 100 mm bending radius repeatedly with tensile force: 150 mm
4-47
Product Characteristics 4.5 SCALANCE X101-1POF
Permitted Environmental Conditions / EMC Operating temperature
-10°C to +60°C
Storage/transport temperature
-40°C to +80°C
Relative humidity in operation
‹ 95% (no condensation)
Operating altitude
2000 m at max 56 °C ambient temperature 3000 m at max. 50 °C ambient temperature
RF interference level
EN 61000-6-3
Noise immunity
EN 61000-6-2
Degree of protection
IP30
Approvals c-UL-us
UL 60950 CSA C22.2 No. 60950
c-Ul-us for hazardous locations 6
UL 1604, UL 2279Pt.15 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. CL. 1, Zone2, AEx nC IIC T..
FM 6
FM 3611 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP. IIC, T.. Ta: ..
C-Tick
AS/NZS 2064 (Class A). EN 61000-6-2, EN 61000-6-4
CE ATEX Zone 2
6
EN60079-15:2005 EN60079-0:2006 II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X
MTBF MTBF
134 years
Construction Dimensions (W x H x D) in mm
6
40 x 125 x 124
Weight in g
550
Installation options
DIN rail S7-300 DIN rail Wall mounting
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
4-48
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Product Characteristics 4.5 SCALANCE X101-1POF
Order Numbers SCALANCE X101-1POF
6GK5101-1BH00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0 manual IE FC stripping tool
6GK1901-1GA00
IE FC blade cassettes
6GK1901-1GB00
IE FC TP standard cable GP
6XV1840 2AH10
IE FC TP trailing cable
6XV1840-3AH10
IE FC TP marine cable
6XV1840-4AH10
IE FC TP trailing cable GP
6XV1870-2D
IE FC TP flexible cable GP
6XV1870-2B
IE FC RJ-45 plug 180 pack of 1
6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10
6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50
6GK1 901-1BB10-2AE0
Note The number of SCALANCE X Industrial Ethernet devices connected in a line influences the frame propagation time. When a frame passes through the media converters of the SCALANCE X-100 series, it is typically delayed by approx. 8µs by the “Cut Through” function of the internal switch - At a network load of 100% these times can increase system-dependently (max. 140 µs)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
4-49
5
Installation and Maintenance
5
5.1 Installation Types of Installation The media converters of the SCALANCE X-100 series can be mounted in different ways: • Installation on a 35 mm DIN rail • Installation on a SIMATIC S7-300 DIN rail • Wall mounting
Note When installing and operating the device, keep to the installation instructions and safetyrelated notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks /2/ manual.
Warning If the cable or conduit entry point exceeds 70°C or the branching point of conductors exceeds 80°C special precautions must be taken. If the equipment is operated in an air ambient of 50°C - 60 °C, only use cables with admitted maximum operating temperature of at least 80°C.
Warning Provisions shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40%. This criteria is fulfilled, if supplies are derived from SELV (Safety Extra Low Voltage), only.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
5-1
Installation and Maintenance 5.1 Installation
5.1.1
Installation on a DIN Rail
Installation Install the media converter on a 35 mm DIN rail according to DIN EN 50022. 1. Place the upper catch of the device over the top of the rail and then push in the lower part
of the device against the rail until it clips into place.
2. Install the electrical connecting cables and the terminal block for the signaling contact. 3. Fit the connectors for the power supply and the signaling contact into the sockets on the
device.
Figure 5-1
5-2
Installation on a DIN rail (35 mm)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Installation and Maintenance 5.1 Installation
Uninstalling To remove the media converter from the DIN rail: 1. First disconnect the TP cable and the FO cables. Remove the terminal block for the
power supply and the signaling contact.
2. Use a screwdriver to release the lower rail catch of the device and pull the lower part
of the device away from the rail.
Figure 5-2
Removing from a DIN rail (35 mm)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
5-3
Installation and Maintenance 5.1 Installation
5.1.2
Installation on a SIMATIC S7 DIN Rail
Installation on a SIMATIC S7-300 DIN rail 1. Place the upper guide at the top of the SCALANCE housing in the S7 DIN rail. 2. Screw the media converter of the SCALANCE X-100 series to the underside of the DIN
rail.
3. Fit the connectors for the power supply. 4. Fit the connectors for the signaling contact. 5. Insert the terminal blocks into the sockets on the device.
Figure 5-3
Installation on a SIMATIC S7-300 DIN rail
Uninstalling To remove the media converters of the SCALANCE X-100 series from the SIMATIC S7-300 DIN rail: 1.
First disconnect all connected cables.
2. Loosen the screws on the underside of the DIN rail and lift the device away from the DIN
rail.
5-4
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Installation and Maintenance 5.2 Grounding
5.1.3
Wall Mounting
Wall Mounting 1. Use four wall plugs (6 mm diameter and 30 mm long). 2. To attach the device, use screws with a diameter of 3.5 mm and a length of 40 mm. 3. Note the drilling templates in chapter 8 Dimension Drawings.
Note The wall mounting must be capable of supporting at least four times the weight of the device.
5.2 Grounding Installation on a DIN Rail The device is grounded over the DIN rail.
S7 DIN Rail The device is grounded over its rear panel and the neck collar screw.
Wall Mounting The device is grounded by the securing screw in the unpainted hole. Please note that the media converter of the SCALANCE X-100 series must be grounded over one securing screw with minimum resistance. If a device of the SCALANCE X100 product line is mounted on a non-conducting base, a grounding cable must be installed. The grounding cable is not supplied with the device. Connect the paint-free surface of the device to the nearest grounding point using the grounding cable.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
5-5
Installation and Maintenance 5.3 Assembling the IE FC Standard Cable
5.3 Assembling the IE FC Standard Cable Assemble the IE FC RJ-45 plug 180 and the IE FC standard cable as follows For information on the assembly, please refer to the instructions that ship with the IE FC RJ-45 plug 180. The robust connectors of the nodes are designed for industry and are PROFINET-compliant. Due to the locking mechanism on the casing, they provide additional strain and torsion relief.
Figure 5-4
5-6
IE FC RJ-45 plug 180
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Installation and Maintenance 5.3 Assembling the IE FC Standard Cable
Inserting the IE FC RJ-45 plug 180 Insert the IE FC RJ-45 plug 180 in the twisted pair port of SCALANCE X005 or of the devices of the product lines SCALANCE X-100 or X-200 until it snaps into place.
Figure 5-5
Inserting the IE FC RJ-45 plug 180
Due to the closing shape and the latching with the PROFINET-compliant connector IE FC RJ-45 plug 180, the sleeve at the TP port of the media converter of the SCALANCE X-100 series ensures a robust, industry-standard node connection which provides additional strain and torsion relief of the twisted pair port.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
5-7
Installation and Maintenance 5.4 Maintenance
Removing the IE FC RJ-45 plug 180 Unlatch the IE FC RJ-45 plug 180 by slightly pressing the latching to remove the plug.
Figure 5-6
Unlatching the RJ-45 plug
If, for lack of space, a manual unlatching is not possible, you can also unlatch the plug with a 2.5 mm screwdriver. Subsequently you can remove the IE FC RJ-45 plug 180 from the twisted pair port.
5.4 Maintenance Maintenance The devices of the product lines SCALANCE X-100 and X-200 are equipped with a selfresetting fuse (resettable fuse / PTC). If the fuse blows (all LEDs are off despite correctly applied power supply), the device should be disconnected from the power supply for approx. 30 minutes before it can be turned on again. If any different fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible.
5-8
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
6
Notes on the CE Mark 6.1 Notes on the CE Mark Product Name
SIMATIC NET
SCALANCE X101-1
6GK5101-1BB00-2AA3
SIMATIC NET
SCALANCE X101-1FL
6GK5101-1BY00-2AA3
SIMATIC NET
SCALANCE X101-1LD
6GK5101-1BC00-2AA3
SIMATIC NET
SCALANCE X101-1POF
6GK5101-1BH00-2AA3
EMC Directive 89/336/EEC "Electromagnetic Compatibility"
Area of Application The products are designed for use in an industrial environment: Area of Application Industrial operation
Requirements Noise emission
Noise immunity
EN 61000-6-4 : 2001 (replaces EN 50082-2)
EN 61000-6-2 : 2001 (replaces EN 50081-2)
Installation Guidelines The products meet the requirements if you keep to the installation instructions and safetyrelated notices as described here and in the manual SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks /1/ when installing and operating the device.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
6-1
Notes on the CE Mark 6.1 Notes on the CE Mark
Conformity Certificates The EU declaration of conformity is available for the responsible authorities according to the above-mentioned EU directive at the following address: Siemens Aktiengesellschaft Bereich Automatisierungs- und Antriebstechnik Industrielle Kommunikation (A&D PT2) Postfach 4848 D-90327 Nürnberg
Notes for Manufacturers of Machines The products are not machines in the sense of the EC Machinery Directive. There is therefore no declaration of conformity for the EU directive on machines 89/392/EEC for these products. If the products are part of the equipment of a machine, they must be included in the procedure for the declaration of conformity by the manufacturer of the machine.
6-2
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
7
References
7
7.1 References Sources of Information and Other Documentation 1. SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks
Order numbers: 6GK1970-1BA10-0AA0 German 6GK1970-1BA10-0AA1 English 6GK1970-1BA10-0AA2 French 6GK1970-1BA10-0AA4 Italian
2. PROFINET Installation Guide
can be ordered from the PROFIBUS User Organization (PNO)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
7-1
8
Dimension Drawings
8
8.1 Dimension Drawing
Figure 8-1
Dimension drawing
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
8-1
Dimension Drawings 8.1 Dimension Drawing
Figure 8-2
8-2
Dimension drawing / Side view
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Dimension Drawings 8.1 Dimension Drawing
Figure 8-3
Bending radii
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
8-3
Glossary AUI Attachment Unit Interface. 10 Mbps TP port (15-pin sub D) for connecting an AUI drop cable. Can be implemented either as DTE (data terminal equipment) or as DCE (data carrier equipment). Is primarily used for the connection to triax segments.
Autocrossover Method with which a TP port is automatically switched between MDI and MDI-X assignment to establish a connection independently of the port assignment of the device to be connected. This ensures that crossover cables are not required. The autocrossover function requires that the respective port is set to autonegotiation mode.
Autonegotiation A technique standardized according to IEEE 802.3 with which the transmission parameter (e.g. 10/100 Mbps, full / half duplex) is automatically negotiated between devices.
C-PLUG The C-PLUG (configuration plug) is a swap medium for backing up the configuration data. If the device is replaced, the configuration can be applied by exchanging the C-PLUG.
CRC Cyclic Redundancy Check. A checksum used in transmission protocols to detect errors in frames.
Cut Through With this method, a frame is forwarded as soon as the destination address is recognized. Therefore the delay does not depend on the frame length. However, if there are problems in a network, also defective frames are forwarded which may increase the network load.
Event for alarms & events: An event is any incident that could be of interest to a client. Although events can also be generated when a condition is met, it is not necessary that they are linked to a condition. Events not linked to conditions include e.g. error messages of the communication system.
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Glossary-1
Glossary
Fault Mask Definition of a desired status (good status); deviations from this status during operation are considered as errors/faults.
FO Fiber optic
Monomode The monomode fiber (also single-mode fiber) typically has a core diameter of 5 to 9 µm. However, the outer diameter is also 125 µm. The actual transmission of the information takes place in the core of the fiber.
Multicast A frame with a multicast address is received by all recipients which are ready for receiving this address.
Multimode In multimode transmission, the pulse is transferred using many modes (waves) which travel along curved paths or which are reflected within the core. Attenuation is mainly caused by physical absorption and dispersion as well as by mechanical bending. Among other things, the amount of attenuation depends on the wavelength of the input light. Multimode fiber-optic cables have an outer diameter of 125 µm and a core diameter of 50 or 62.5 µm. Due to the larger core diameter, the pulse edges degrade more than in single mode transmission, which results in shorter transmission distances.
OSM Optical Switching Module – SIMATIC NET Ethernet switch with optical ports.
Glossary-2
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Glossary
Reconfiguration Time Time required to restore a functional configuration in case of a device failure or an interruption of a connection line.
Redundancy Manager (RM) Switch in a ring topology which does not forward frames between its ring ports in case of functioning connections between all other switches. As soon as a connection between two switches is interrupted, the redundancy manager forwards frames between its ring ports to re-establish an intact connection between all switches.
Ring Port Two ports in a switch via which it is connected with other switches to form a ring. One switch in the ring must be configured as redundancy manager. This switch sends test frames via the ring ports that are forwarded by all ring ports of other switches in the ring. This ensures that the ring does not have any interruptions.
Segment In the Ethernet bus system, the transceivers connected over the bus cable along with the nodes connected over patch cables form a segment. Several such segments can be connected via repeaters. When using twisted pair and fiber-optic cables, each subsection forms one segment.
Signaling Contact Floating relay contact via which detected error/fault states are signaled.
Store and Forward An entire frame is received, its validity checked (checksum, length etc.) and then buffered. Invalid frames are discarded, i.e. a frame is forwarded only if it is error-free.
TP Port Port with TP connector (RJ-45 jack)
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
Glossary-3
Index A
M
ATEX, 1-2, 2-2 Autonegotiation SCALANCE X101-1, 4-4 SCALANCE X101-1LD, 4-28 SCALANCE X101-1POF, 4-40
MDI /MDIX autocrossover function SCALANCE X101-1, 4-5 SCALANCE X101-1LD, 4-29 MDI /MDIX Autocrossover function SCALANCE X101-1FL, 4-17 SCALANCE X101-1POF, 4-41
B Button SCALANCE X101-1, 4-7 SCALANCE X101-1FL, 4-20 SCALANCE X101-1LD, 4-32 SCALANCE X101-1POF, 4-44
C CE mark, 1-2 Class1 Laser, 4-29 Connector pinout SCALANCE X101-1, 4-4 SCALANCE X101-1FL, 4-16 SCALANCE X101-1LD, 4-28 SCALANCE X101-1POF, 4-40 C-Tick mark, 1-2
F Fault indicator (red LED) SCALANCE X101-1, 4-9 SCALANCE X101-1FL, 4-21 SCALANCE X101-1LD, 4-33 SCALANCE X101-1POF, 4-45 FM mark, 1-2 Fuse, 5-8
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A
N Network topology, 3-1 Ring topology, 3-2 Star topology, 3-2
O Optical star topology, 3-2
P Port status display (green/yellow LEDs) SCALANCE X101-1POF, 4-45 Port status indicator (green/yellow LEDs) SCALANCE X101-1, 4-9 SCALANCE X101-1FL, 4-21 SCALANCE X101-1LD, 4-33 Possible Attachments SCALANCE X101-1, 4-3 SCALANCE X101-1FL, 4-15 SCALANCE X101-1LD, 4-27 SCALANCE X101-1POF, 4-39 Power indicator (green LED) SCALANCE X101-1, 4-9 SCALANCE X101-1FL, 4-21 SCALANCE X101-1LD, 4-33 SCALANCE X101-1POF, 4-45 Power supply SCALANCE X101-1, 4-6 SCALANCE X101-1FL, 4-18 SCALANCE X101-1LD, 4-30 SCALANCE X101-1POF, 4-42
Index-1
Index
R Ring topology, 3-2, 3-3
S Signaling contact SCALANCE X101-1, 4-7 SCALANCE X101-1FL, 4-19 SCALANCE X101-1LD, 4-31 SCALANCE X101-1POF, 4-43
T TL display (green LED) SCALANCE X101-1, 4-10 SCALANCE X101-1FL, 4-22 SCALANCE X101-1LD, 4-34 SCALANCE X101-1POF, 4-46
U UL mark, 1-2
Index-2
Industrial Ethernet Media Converters SCALANCE X-100 Series Commissioning Manual, 07/2008, A2B00051521A