Preview only show first 10 pages with watermark. For full document please download

1/5/17 Equipment Used Model No Stock No Calibration Due Date

   EMBED


Share

Transcript

Report No: L121605916 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com L121605916 Report No: Report Prepared For: Model Number: Test: Issue Date: 2/8/2017 Revolution Lighting 4139 Guardian St. Simi Valley CA 93063 131434-203 Electrical and Photometric tests Standards Used: Appropriate part or all test guidelines were used for test performed: IESNA LM79: 2008 Approved Methods for Electrical and Photometric Measurements of Solid-State Lighting Products ANSI NEMA ANSLG C78.377: 2008 Specification of the Chromaticity of Solid State Lighting Products ANSI C82.77:2002: Harmonic Emission Limits-Related Quality Requirements for Lighting Equipment Description of Sample: Client submitted the sample. Received in working and undamaged condition. No modifications were necessary. Testing Condition: Fixture is tested with no special conditions. Sample Arrival Date: 12/21/16 Date of Tests: 12/22/16 Seasoning of Sample: No seasoning was performed in accordance with IESNA LM-79. - 1/5/17 Equipment List Equipment Used Chroma Programmable AC Source Yokogawa Digital Power Meter ITECH Fluke Digital Thermometer LLI Type C Goniophotometer System LLI 2M Sphere LLI Spectroradiometer Model No Stock No Calibration Due Date 61604 WT210 IT6122 52k/J RMG-C-MKII 2MR97 SPR-3000 PS-AC02 MT-EL06-S1 PS-DC03-S1 MT-TP02-GC CD-LL04-GC CD-SN03-S2 MT-SC01-S2 -11/28/17 11/28/17 11/28/17 --Before Use *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 1 of 4 Report No: L121605916 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Test Summary Manufacturer: Model Number: Driver Model Number: Total Lumens: Input Voltage (VAC/60Hz): Input Current (Amp): Input Power (W): Input Power Factor: Current ATHD @ 120V(%): Current ATHD @ 277V(%): Efficacy: Color Rendering Index (CRI): Correlated Color Temperature (K): Chromaticity Coordinate x: Chromaticity Coordinate y: Ambient Temperature (oC): Stabilization Time (Hours): Total Operating Time (Hours): Off State Power(W): Revolution Lighting 131434-203 N/A 3639.87 120.00 0.24 27.98 0.99 13% N/A 130 84 4016 0.3803 0.3785 25.0 1:20 1:55 0.00 FIG. 1 LUMINAIRE *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 2 of 4 Report No: L121605916 Percent Output 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Spectral Power 1.0 0.8 0.6 0.4 0.2 0.0 380 Wavelength W/m2nm 380 390 400 410 420 430 0.0011 0.0015 0.0036 0.0153 0.0674 0.2036 CRI & CCT x 0.3803 y 0.3785 u' 0.2243 v' 0.5023 CRI 83.90 CCT 4016 Duv 0.00086 R Values R1 81.99 R2 90.05 R3 95.82 R4 82.76 R5 82.32 R6 86.29 R7 86.36 R8 65.30 R9 10.88 R10 76.57 R11 81.90 R12 66.70 R13 83.98 R14 97.66 430 440 450 460 470 480 490 500 480 0.5164 1.0000 0.6162 0.4022 0.3249 0.4044 0.5192 530 510 520 530 540 550 560 570 580 Wavelength(nm) 0.6034 0.6519 0.6926 0.7420 0.7961 0.8511 0.9059 580 590 600 610 620 630 640 630 680 0.9546 0.9860 0.9833 0.9418 0.8618 0.7526 0.6326 650 660 670 680 690 700 710 730 0.5122 0.4033 0.3092 0.2325 0.1733 0.1277 0.0936 780 720 730 740 750 760 770 780 0.0683 0.0495 0.0362 0.0268 0.0198 0.0147 0.0126 CIE 1931 Chromaticity Diagram Y 0.9 520 0.8 530 540 510 0.7 550 560 0.6 570 500 0.5 580 590 0.4 600 0.3803, 0.3785 0.3 610 620 630 640 650 700 490 0.2 480 0.1 470 460 0 0 0.1 440 430 380 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 X *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 3 of 4 Report No: L121605916 8165 E Kaiser Blvd. Anaheim, CA 92808 www.lightlaboratory.com Test Methods Photometric Measurements - Goniophotometer A Custom Light Laboratory Type C Rotating Mirror Goniophotometer was used to measure candelas(intensity) at each angle of distribution as defined by IESNA for the appropriate fixture type. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Spectral Measurements - Integrating Sphere A Sensing Spectroradiometer SPR-3000, in conjunction with Light Laboratory 2 meter integrating sphere was used to measure chromaticity coordinates, correlated color temperature(CCT) and the color rendering index(CRI) for each sample. Ambient temperature is set to 25oC and is measured from the center of the fixture, within 1ft from the outside of the fixture. Temperature is maintained at 25oC throughout the testing process and the sample is stabilized for at least 30mins and longer as necessary for the sample to achieve stabilization. Electrical measurements are measured using the listed equipment. Disclaimers: This report must not be used by the customer to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Government. Report Prepared by : Keyur Patel Test Report Released by: Test Report Reviewed by: Jeff Ahn Engineering Manager Steve Kang Quality Assurance *Attached are photometric data reports. Total number of pages: 9 *All Results in accordance to IESNA LM-79-2008: Approved Method for the Electrical and Photometric Testing of Solid-State Lighting. Page 4 of 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605916.IES DESCRIPTION INFORMATION (From Photometric File) IESNA:LM-63-2002 [TEST] L121605916 [TESTLAB] LIGHT LABORATORY, INC. [ISSUEDATE] 1/5/2017 [MANUFAC] REVOLUTION LIGHTING [LUMCAT] 131434-203 [LUMINAIRE] 27W 4000K EX39 OMNIDIRECTIONAL UTILITY LAMP [BALLASTCAT] N/A [LAMPPOSITION] 0,0 [LAMPCAT] N/A [OTHER] INDICATING THE CANDELA VALUES ARE ABSOLUTE AND [MORE] SHOULD NOT BE FACTORED FOR DIFFERENT LAMP RATINGS. [INPUT] 120VAC, 27.98W [TEST PROCEDURE] IESNA:LM-79-08 CHARACTERISTICS Lumens Per Lamp Total Lamp Lumens Luminaire Lumens Total Luminaire Efficiency Luminaire Efficacy Rating (LER) Total Luminaire Watts Ballast Factor CIE Type Spacing Criterion (0-180) Spacing Criterion (90-270) Spacing Criterion (Diagonal) Basic Luminous Shape Luminous Length (0-180) Luminous Width (90-270) Luminous Height N.A. (absolute) N.A. (absolute) 3640 N.A. 130 27.98 1.00 General Diffuse N.A. N.A. N.A. Circular w/ Sides 0.29 ft (Diameter) 0.29 ft (Diameter) 0.33 ft LUMINANCE DATA (cd/sq.m) Angle In Degrees Average 0-Deg Average 45-Deg Average 90-Deg 45 55 65 75 85 32500 33565 33178 33165 35803 32500 33565 33178 33165 35803 32500 33565 33178 33165 35803 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 1 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605916.IES CANDELA TABULATION 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175 180 0 196.69 198.06 205.30 220.14 239.14 262.73 289.87 312.82 331.36 345.66 356.65 362.93 362.64 353.72 343.23 337.81 336.11 336.57 336.17 335.02 330.95 324.51 315.09 302.45 286.73 268.11 245.75 220.01 190.67 156.75 121.84 91.71 64.65 36.73 14.05 3.04 0.00 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 2 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605916.IES ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-20 0-30 0-40 0-60 0-80 0-90 10-90 20-40 20-50 40-70 60-80 70-80 80-90 90-110 90-120 90-130 90-150 90-180 110-180 0-180 82.24 204.81 401.03 992.47 1701.43 2068.41 2049.27 318.80 586.06 942.06 708.96 358.34 366.98 707.30 1006.9 1246.88 1516.02 1571.46 864.16 3639.87 N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. 2.30 5.60 11.00 27.30 46.70 56.80 56.30 8.80 16.10 25.90 19.50 9.80 10.10 19.40 27.70 34.30 41.70 43.20 23.70 100.00 Total Luminaire Efficiency = N.A.% ZONAL LUMEN SUMMARY Zone Lumens 0-10 10-20 20-30 30-40 40-50 50-60 60-70 70-80 80-90 90-100 100-110 110-120 120-130 130-140 140-150 150-160 160-170 170-180 19.15 63.09 122.57 196.23 267.27 324.17 350.62 358.34 366.98 364.74 342.56 299.60 239.98 170.15 98.99 43.42 11.37 0.65 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 3 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605916.IES COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD Effective Floor Cavity Reflectance 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 109 109 109 109 94 88 82 77 84 74 66 59 75 63 54 46 68 55 45 38 62 48 39 31 57 43 33 27 52 38 29 23 48 34 26 20 45 31 23 17 42 28 20 15 101 101 101 101 87 81 76 71 77 68 61 54 69 58 50 43 62 51 42 35 57 44 36 29 52 39 31 25 48 35 27 21 44 32 24 18 41 29 21 16 38 26 19 14 87 69 57 49 43 37 33 30 27 25 22 74 58 48 41 35 31 28 25 22 20 19 62 47 39 33 28 25 22 20 18 17 15 57 37 27 21 17 13 11 9 8 7 6 87 65 52 42 36 30 26 23 20 18 16 87 61 47 37 30 25 21 18 16 14 12 74 54 43 35 30 25 22 19 17 15 14 74 52 39 31 25 21 18 15 13 11 10 62 45 35 29 24 20 18 15 14 12 11 Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. 62 43 32 25 20 17 14 12 10 9 8 Page 4 IES INDOOR REPORT PHOTOMETRIC FILENAME : L121605916.IES POLAR GRAPH 363 272 181 2 91 1 Maximum Candela = 362.93 Located At Horizontal Angle = 0, Vertical Angle = 55 # 1 - Vertical Plane Through Horizontal Angles (0 - 180) (Through Max. Cd.) # 2 - Horizontal Cone Through Vertical Angle (55) (Through Max. Cd.) Photometric Toolbox Professional Edition - Copyright 2002-2012 by Lighting Analysts, Inc. Calculations based on published IES Methods and recommendations, values rounded for display purposes. Results derived from content of manufacturers photometric file. Page 5