Preview only show first 10 pages with watermark. For full document please download

1 Contents • Please Read The Manual Carefully Before Using This Unit

   EMBED


Share

Transcript

Contents • • • Please read the manual carefully before using this unit. Please refer to cautions mentioned in the manual to avoid improper usage of this unit. Please keep the manual for your future reference. Safety Cautions. .....................................................................................................2 Brief Introduction to PHC-208TM...........................................................................3 Description of the Main Unit ...................................................................................4 Operation for Manual Mode & Auto Mode .............................................................5 Electrodes & Accessories .......................................................................................6 Large LCD Screen Introduction ..............................................................................7 Operational Instructions .........................................................................................8 Maintenance and Storage after Use .......................................................................9 Acupoint Selection and Treatment for Discomfort ...............................................10 Acupoint Selection and Relief for Discomfort ................................................ 11-14 Diagram of Palm Reflection Zones & Treatment...................................................15 Diagram of Palm Reflection Zones & Treatment...................................................16 Troubles and Solutions .........................................................................................17 Specifications .......................................................................................................18 1 Safety Cautions Brief Introduction to PHC-208TM 1 Never use the equipment with the following instruments: • Heart rate regulator and body built-in electronic therapeutic instruments • Artificial cardiopneumatic pacemaker, electronic life support and treatment instruments • Cardiometer and ambulatory electronic therapeutic instruments Properties 2 It is advised to follow a doctor’s advice for patients who are under medical treatment or suffering from the following: • Malignant tumor • VD infection • In menstrual phase or pregnancy • Do not adopt the equipment near heart for heart disease patients • Fever above 38°C • Abnormal cutaneous anaphylaxis • Do not adopt the equipment at the diseased heat region, eyeballs, inside mouth, genital parts and external skin trauma • Do not use the equipment simultaneously with other instruments Brief Introduction of PHC-208TM 3 Cautions • When you feel discomfort or abnormality while use, stop using and contact your doctor • Keep away from babies, children and others who are not able to express themselves freely • Avoid moisture, high temperature and using in the bath or bath place • Do not put battery into fire as it may explode and cause an accident • Do not attempt any repair; contact your local dealer for any technical assistance and or product failure PHC-208TM is based on super low frequency electrotherapy. The objective is to produce a therapeutic effect similar to the one produced using a traditional Chinese acupuncture needle. The low frequency electrical impulses stimulate your main and collateral body accupoints imitating the actual feeling of massaging, pounding on your back, performing acupuncture and applying cupping techniques. The user may feel relief immediately for acute conditions such as gasteralgia or lower limb pains by using the PHC-208TM. PHC-208TM offers the latest advances as a new generation health-care product. The PHC-208TM is an advanced user friendly TENS instrument. It applies the physics of bionics, traditional Chinese medicine, and clinical treatment methods. It offers not only the seven functions presented in our previous product series, but has added distinctive capabilities in treating Hypertension and Hypotension. PHC-208TM Functional Advantages • • • • • • • • Therapeutic Indications 1. 2. 3. 2 Advanced microcomputer control system with safe, easy operation Eight selectable functions that can be adjusted based on users’ preference: Acupuncture, Massage, Scraping, Beating, Manipulation, Slimming, Blood Pressure and Feet-cure Large LCD screen with easy to read full featured body display 30 mins auto-off system that automatically switches off the unit after use User selectable AUTO and MANUAL Modes with the eight functions that can be automatically circulated step by step under AUTO Mode Intensity automatically adjusts to the lowest level each time when the function is changed manually to assure optimum comfort and safety Medical pads and Acupoint Pen can be freely applied to any part of the body and attached to the separate feet massage slipper Smart outlook, portable and easy to carry General malaise: fatigue, nervosism, sore waste and back, shoulder and leg. A large variety of chronic diseases that can be cured by acupuncture and manipulation: stain, gasteralgia, toothache, ischialgia, menoxenia, impotence, sexual disorder and others. Hairdressing: bantingism, post partum belly looseness, hump breast, facial ache and facial pigment ediment. 3 Description of the Main Unit Operation for Manual Mode & Auto Mode Components of Main Unit ➅ Operation for Manual Mode & Auto Mode Electrode Socket ➄ ➀ Language Selection Key LCD Screen Power Switch Key (On/Off) ➂ Intensity Increase Key ➃ Intensity Decrease Key ➁ Function Selection Key Components & Functions of Main Unit 1. Mode selection: Manual/Auto Mode. 1) The Mode is Manual Mode after opening the device, and it can be changed to Auto Mode ➃ once pressing 4 over 3 seconds. 2) Change Manual Mode to Auto Mode, and the intensity degree decreases 1, and the time changes to 03 minutes. 3) Change Auto Mode to Manual Mode, and the intensity degree becomes 01, and the time changes to 30 minutes. ➁ 2. Manual Mode: 1) Under Manual Mode, Press 2 to change the function to next one that user needs, and the LCD arrow will direct the selected function, and the time is 30 minutes. 2) The intensity is 01 automatically to avoid the sudden change. Press 3 or 4 to in crease or decrease the intensity. 1 Power Switch key: Open: Press it to start, the original LCD shows: Manual Mode, the arrow directs function of Massage, intensity is 01, and time is 30 minutes. Close: Press it over 3 seconds to close, or close automatically after 30 minutes. 2 Function Selection key: Press it to select eight functions: Acupuncture, Massage, Scraping, Beating, Manipulation, Slimming, Blood Pressure, Feet-cure. 3 Intensity Increase key: Press once to increase 1 degree, and the maximum degree is 32. 3. Auto Mode: 1) Under Auto Mode, and the function can be automatically changed from Massage to Feet-cure every 3 minutes. 2) The time for each function is 3 minutes, and the device will be switched off automatically ➃ after all functions finish. 3) Under Auto Mode, the intensity doesn’t change when the function changes, and press 3 or 4 to in/decrease intensity. ➁ ➂ 4 Intensity Decrease key / Manual/Auto Mode Key: Press once to decrease 1 degree, and the minimum degree is 01. Press this key over 3 seconds, Mode can be changed freely between Auto and Manual. 5 LCD Screen: Directly shows the output condition. 6 Electrode Socket: Insert the plug to the device. 4 Treatment Guide 1) A standard number of treatments per day is 1-2. Some people may feel tired during the first week of use. In this case, lower the intensity, shorten the time, and also limit the number of treatments to one a day. 2) Duration — 10 to 15 minutes for each region 5 ELECTRODES & ACCESSORIES ELECTRODES Large LCD Screen Introduction Electrodes Chord Plug Acupoint pen Big Adhering Pads (x2) ACCESSORIES chord winder, leather bag, battery, foam plastic box. Foam Plastic Box Leather Bag NOTE: 7” Battery (AAAX3) When the function is certainly adjusted, the corresponding black points are shown on the human body simultaneously, then put the medical pads directly there for the treatment. Chord Winder 6 7 Operational Instructions Maintenance and Storage After Use Preparation Prior to Use 1. Cleaning the electrodes 1 Battery installation 1) Push off the battery deck cover and open the deck; 2) Insert three 7# batteries, paying attention to polarity. 3) Close the deck cover firmly. After use, wipe off the dirt on the surface of adhering pads with wet cloth (thin silk or glabrous woolen cloth) and place them against the chord winder. If the pads are more than dirty, you can wash them with clean water and regain their stickness after drying. If pad is still not adhesive after drying, skin might feel stabbing pain. In this case you may adopt one or two drops of water to moisturize the pad for better adhesion. But excessive water shall be avoided which may weaken the adhesion. Cold weather may affect the adhering force. Adhering pad is renewable. If adhesion becomes too poor, new pad is available for replacing. To keep the clips clean and dry, you can wipe them with alcohol. 2 Preparation of electrodes 1) Peel off the smooth film on the adhering pads. 2) Put the adhering pads on the chord winder after use. 3 Placing electrodes 1) Wipe the position of body to be massaged with wet towel to remove oil, dirt, sweat and makeup; 2) Stick the electrodes directly onto the skin to be massaged. 3) Treatment can not be effected unless both of the two electrodes are placed onto the body surface. It is not necessary to place the two electrodes symmetrically. 4) Before treating, you may choose two pieces of medical pads, or choose acupoint pen with one piece of medical pad, as following picture shows. 8 2. Cleaning the main unit The main unit and electrodes should be cleaned after use. Regular cleaning of accessories is necessary. Clean the main unit and electrodes with soft cloth without dilutions, patrol or other volatile solutions. 3. Storage Keep away from moisture, high temperature, direct sunlight and water. Keep away from children to avoid contrived damage. Take out the batteries if you will not use it for a certain long time. 9 Acupoint Selection and Treatment for Discomfort You should choose the acupoints to be treated according to your symptom. If you just want to have massage to release fatigue, you may choose the acupoints according to the acupoint map or just massage the sore place. However, if you want to treat various diseases, you should choose the proper acupoints according to the acupoint selection table or other medical books. Correct selection of acupoints helps a lot to cure your disease, and wrong one may cause vain effect or even side effect. Main Symptom Accompanying Symptom Acupoints Selected Therapy Neck ache Reluctant to get up, heavy head, trance, dizzy Aching point on neck, dazhui, jianjing, jianyu Massage, back stroke for 15 mins. Massage whenever aching Vertebra ache Humeral callus ache, swollen shoulder, stiff shoulder Aching point on Massage, shoulder, jianyu, jianjin, Manipulation, quchi Stroke Arm ache Swollen arm, heavy and inertia, arm muscle tension, difficult to move Shaohai, quze, qiemen, yanggu, yangchi Abdomen ache Hard to sleep deeply, getting Qihai, shenque, zhongwan, juque, up frequently during night, weiyu discomfort in abdomen Sore waste Difficult to bent Fengmen, shenyu, Back stroke, dachangyu, weizhong, Massage, Cupping chengshan Sleepy eyes Difficult to bent Hegu, yangxi, quchi, qingming Nose snuffles Faint hearing, itching nose, discomfort Yingxiang, quchi Acupuncture Sore and collap sing laps Difficult to climb stairs, heavy legs, easy to get fever, difficult toe and ankle movement, feet numbness and cold Shenyu, cichou, weizhong, zhishi Massage, Acupuncture, Manipulation Poor complexion Easy to grow comedo, dry and itching skin Hegu, quchi, yingxiang Acupuncture, Massage SYMPTOM: Abdomen Ache ACUPOINT: Qihai MODE: Massage TIME: 15 mins SYMPTOM: Atrophic Arthritis ACUPOINT: Waiguan MODE: Manipulation TIME: 15 mins SYMPTOM: Acute Lumbar Sprain ACUPOINT: Mingmen MODE: Massage TIME: 15 mins SYMPTOM: Body Fitness ACUPOINT: Guanyuan, Qihai MODE: Acupuncture TIME: 15 mins Massage, Cupping Massage, Acupuncture Massage, acupuncture, Manipulation Just choose one or several acupoint(s) for general discomfort, waist and back ache, and headache. Not necessarily treating all acupoints as listed above. 10 Acupoint Selection & Relief for Discomfort SYMPTOM: Arm Ache ACUPOINT: Chize MODE: Cupping TIME: 20 mins WARNING: Consult with your Physician prior to use. 11 Acupoint Selection & Relief for Discomfort Acupoint Selection & Relief for Discomfort SYMPTOM: Cervical Spondylopathy ACUPOINT: Tianzong MODE: Cupping TIME: 25 mins SYMPTOM: Hypertension ACUPOINT: Quchi MODE: Massage TIME: 20 mins SYMPTOM: Constipation ACUPOINT: Dachangshu MODE: Acupuncture TIME: 15 mins SYMPTOM: Impotence ACUPOINT: Ciliao MODE: Manipulation TIME: 15 mins SYMPTOM: Chronic Lumbar Muscle Strain ACUPOINT: Yaoyangguan MODE: Manipulation TIME: 20 mins SYMPTOM: Manoxenia ACUPOINT: Qihai MODE: Acupuncture TIME: 30 mins SYMPTOM: Neck Ache ACUPOINT: Jianjing MODE: Massage TIME: 15 mins SYMPTOM: Diarrhea ACUPOINT: Guanyuan MODE: Manipulation TIME: 20 mins SYMPTOM: Cold/Headache ACUPOINT: Hegu MODE: Acupuncture TIME: 15 mins SYMPTOM: Gastralgia ACUPOINT: Qimen MODE: Acupuncture TIME: 30 mins WARNING: Consult with your Physician prior to use. 12 SYMPTOM: Insomnia ACUPOINT: Pishu MODE: Manipulation TIME: 20 mins SYMPTOM: Rheumatic Arthritis ACUPOINT: Liangqiu MODE: Manipulation TIME: 20 mins WARNING: Consult with your Physician prior to use. 13 Acupoint Selection & Relief for Discomfort SYMPTOM: Sore Waste ACUPOINT: Shenshu MODE: Massage TIME: 15 mins Diagram of Palm Reflection Zones & Treatment SYMPTOM: Stomach Spasm ACUPOINT: Zhongwan MODE: Acupuncture TIME: 30 mins SYMPTOM: Sore & Collapsing Laps ACUPOINT: Zusanli MODE: Acupuncture TIME: 15 mins SYMPTOM: Vertebra Ache ACUPOINT: Dazhui MODE: Manipulation TIME: 20 mins SYMPTOM: Stiff Neck ACUPOINT: Fengchi MODE: Cupping TIME: 20 mins • WARNINGS: Consult with your Physician prior to use. 14 Palm Acupoint • Palm Edge Acupoint Main Acupoint 15 Troubles and Solutions Diagram of Palm Reflection Zones & Treatment Status of the Product Cause Solutions Battery deck is stained with foreign objects Check and remove Batteries used up or polarity incorrect Check the cause and remove or re-install batteries Plug inserted in the jack firmly? Check and correct connection between electrode and chord, chord and jack Electrode contacting skin correctly? Stick the mat firmly onto the skin Dirt on mat surface? Clean or change mat Oil on skin? Clean your skin Batteries used up Replace batteries Treated surface flushing, itching, or twinging Skin pathergy against mat contact Check skin allergic history. For slight allergy, change position or shorten treatment time. For severe allergy, stop treatment or take disentilization therapy. Power can not be turned on after automatic stop with timer Normal Turn off the power and turn on 3 seconds later. No stimulation or no LCD display Stimulation becomes weak or tingling Output stops during treatment for less than 15 minutes since use. SPECIFICATIONS Power Frequency Power consumption Service life of battery Dimensions of main unit Weight 16 AAA X 3 (7# battery, 3 pieces) 1-50 Hz Less than 180mw Continuously 45 hours in normal condition. 153X70X18 mm. About 90g 17