Preview only show first 10 pages with watermark. For full document please download

1 © Copyright 2011 – Jack Fuse Pp4f - V4 Data

   EMBED


Share

Transcript

Vin P1 Ramseon Technology  J4 F4 J3 F3 J2 F2 J1 F1 F5 SPARE PP4FR – V4 Data Sheet  REFER TO DATA BEFORE USE Fused power distribution module for electronic access control.  P2 Power Port 4F Image not to scale The Power Port 4FR is designed to provide protected power distribution for building electronic access control and security devices.   Applications  • • • • Power distribution for electronic access control and security devices  Fused over current protection  Direct expansion module for the Power Port 8FR  Green options board  Features  • • • • • Four individually fused outputs each with status LED  Individually field selectable power outputs – fire power or standard power.  On board spare fuse holder  DIN rail mounting  Drastically reduced material list, cost and install time compared to traditional methods  Technical Data  Input voltage range  0‐30V DC     Max standard power current   10A  Max fire power current  10A  Max constant current per output  2.5A   Max alarm contact current   2A      Fused outputs  4  Fuse type  2A M205 NB Mounting   DIN rail mounts supplied (other options available) On board spare fuse holders  1      Dimensions (with mounting options)  54 L X 75 W X 35 H (mm) Mounting holes  7 X 3.5mm (to suit M3 bolts or #4 Screws)   Connections  Terminal   Description  Max Conductor Size (P1) + ‐ FT ‐ Gnd  Power input  2mm (P2) 1 ‐ 4  Fused outputs 1.5mm 2 2         1  © Copyright 2011 – Jack Fuse    PP4F ‐ V4 Data    Function:  Power Input  The PP4F module can be powered in several ways; from the expansion output of the PP8FR, by any suitable DC supply connected to  the clearly marked input barrier terminals or a combination of direct DC supply and a separate fire relay.  Vin P1 J4 F4 J3 F3 J2 F2 J1 F1 F5 SPARE DC  Power  Supply REFER TO DATA BEFORE USE Power Port 4F P2 Standalone Module  Fused Outputs  The four power outputs are each individually protected by a glass fuse that will activate when a current greater than the fuse rating  is drawn via the output.   The four outputs can be fed either directly from the power input or the fire power input. This function is set via a link for each  output and can be changed at any time in the field to suit requirements.  Each output has an individual status LED. The LED will be active whenever power is available at the output. The LED will deactivate  in the event of a blown fuse or if the associated power input has been removed. Each status LED is located directly under the  appropriate glass fuse to greatly aid visual confirmation of fuse status.  Expansion  The PP4F is designed as a direct expansion module for the PP8FR. A number of additional PP4F modules can be fitted at any time as  long as current limits of the PP8FR fire relay, modules and power supply are not exceeded.   Expansion Examples  ABA JF N/C FIP  Contact PR KF ABA S P JF JR DF P1 DC  Power  Supply V In JDC REFER TO DATA J8 F8 J7 F7 J6 F6 J5 F5 J4 F4 P1 DC  Power  Supply F9 SPARE Controller/Feild  Equipment Power F10 SPARE V In JDC REFER TO DATA J8 F8 J7 F7 JR DF J6 F6 J5 F5 J4 F4 F9 SPARE F3 J3 F3 F2 J2 F2 J1 F1 J1 F1 P2 Aux Out P3 Controller/Feild  Equipment Power F10 SPARE J2 Power Port 8FR Fire Trip Alarm  Input BEFORE USE J3 P2 Aux Out S P Fire Relay BEFORE USE P1 PR KF Fire Relay Power Port 8FR P3 Vin J4 F4 J3 F3 J2 F2 J1 F1 Additional Fire Relay Or PP8FR F5 SPARE REFER TO DATA BEFORE USE Power Port 4F Further Expansion P2   Further Expansion 2  © Copyright 2011 – Jack Fuse    PP4F ‐ V4 Data  J2 F2 J1 F1 P2 Aux Out P1 Power Port 8FR P3 Vin J4 F4 J3 F3 J2 F2 J1 F1 F5 SPARE REFER TO DATA BEFORE USE P1 Power Port 4F P2 Vin J4 F4 J3 F3 J2 F2 J1 F1 F5 SPARE REFER TO DATA Further Expansion BEFORE USE Power Port 4F P2 Cascaded PP4F Modules  Additional Applications   Direct expansion for the PP8FR  Perfect size for small security installations with fuses for PIRs keypad/expander power and siren/strobes. Cascade more modules to  suit any size system.  Green options board. Save power and turn off all unnecessary security devices when the alarm system is disarmed. This can be done  by switching the secondary power input via a relay in the alarm panel or standalone key switch.  Mounting  The PP4F module is supplied pre‐fitted with cost effective DIN rail mount clips suitable for most DIN rail profiles.   Several other mounting options are possible. The PP4F PCB has a number of 3.5mm mounting holes than can be used in conjunction  with M3 spacers, standoffs or self adhesive pillars. Offset mounting holes are provided to allow use of adhesive standoffs where  modules are mounted immediately next to each other. The PP4F is also suitable for use with popular “Snap Track” made by TE  Connectivity part number 4TK2.  Ordering Codes  PP8FR  PP4F  Power Port 8FR supplied with a DIN rail mount kit, 12VDC relay and 2A NB fuses.  Power Port 4F supplied with a DIN rail mount kit and 2A NB fuses   More Information    For complete install notes, data sheets and technical support please visit www.jackfuse.com    3  © Copyright 2011 – Jack Fuse    PP4F ‐ V4 Data