Preview only show first 10 pages with watermark. For full document please download

1 Introduction............................................ 4 2

   EMBED


Share

Transcript

R REEPPA AIIR R IIN NSSTTR RU UC CTTIIO ON N Dishwasher 3.15 Filter system....................................................................... 28 3.16 Pump sump ........................................................................ 29 3.17 Water switch....................................................................... 30 3.18 Heating pump ..................................................................... 31 3.19 Drain pump......................................................................... 34 3.20 Aqua sensor (optional)...................................................... 35 Qualifications of service technicians ................................. 6 3.21 Spray system ..................................................................... 36 2.2 Identification of danger levels............................................. 6 3.22 Basket system.................................................................... 37 2.3 Identification of damage to property .................................. 6 3.23 Dosing assistant ................................................................ 45 2.4 General safety instructions ................................................. 7 3.24 Water outlet ........................................................................ 46 3 CONSTRUCTION AND FUNCTION.............. 9 3.25 Non-return valve ................................................................ 47 3.1 Chapter describing design and function............................ 9 3.26 Ventilation sequence ......................................................... 48 3.2 Door sensor ........................................................................ 10 3.27 Dispenser ........................................................................... 49 3.3 Door lock/Childproof lock ................................................. 11 3.28 Low rinse-aid sensor ......................................................... 51 3.4 Safety system ..................................................................... 13 3.29 Door springs ...................................................................... 52 3.5 Aquastop valve................................................................... 15 3.30 Variable hinge .................................................................... 53 3.6 Water inlet........................................................................... 16 3.31 Foot adjustment ................................................................. 54 3.7 Heat exchanger .................................................................. 18 3.32 Customer settings ............................................................. 55 3.8 Flow sensor ........................................................................ 19 3.33 Emotion light (optionally).................................................. 56 3.9 Expansion opening ............................................................ 20 3.34 Info light (optional) ............................................................ 57 3.10 Free flow line ...................................................................... 21 3.35 TimeLight (optional) .......................................................... 58 3.11 Heat exchanger drainage valve......................................... 22 3.36 Power module .................................................................... 60 3.12 Water softening system..................................................... 23 3.37 Power cords – country versions....................................... 61 3.13 Regeneration valve ............................................................ 25 3.38 D-bus2 / appliance software ............................................. 62 3.14 Low salt detection.............................................................. 27 3.39 Weight................................................................................. 63 1 INTRODUCTION............................................ 4 1.1 Purpose of the document .................................................... 4 1.2 General symbols .................................................................. 4 1.3 Safety-relevant symbols ...................................................... 5 2 SAFETY ......................................................... 6 2.1 155_58300000149128_ara_en_c – 12.02.13 Seite 1 von 181 5.18 Removing outer door........................................................107 5.19 Variable hinge – installation, optional.............................109 5.20 Replacing the dispenser ..................................................122 5.21 Installing the detergent cover ..........................................124 5.22 Replacing infolight............................................................127 5.23 Replacing TimeLight.........................................................128 5.24 Replacing the fascia .........................................................129 5.25 Replacing the door springs .............................................131 5.26 Replacing heat exchanger ...............................................137 Testing water hardness in the appliance ......................... 79 5.27 Replacing flow sensor......................................................140 5.2 Testing/replacing the door sensor ................................... 83 5.28 Replacing drainage valve.................................................141 5.3 Testing dispenser electrically ........................................... 84 5.29 Replacing the regeneration valve....................................142 5.4 Checking EmotionLight (optionally)................................. 85 5.30 Replacing the drainage hose ...........................................144 5.5 Testing the regeneration valve electrically ...................... 86 5.31 Replacing the supply hose ..............................................145 5.6 Testing heat exchanger drainage valve electrically........ 87 5.32 Replacing the power module ...........................................147 5.7 Testing Aquastop valve electrically.................................. 88 5.33 Replacing base panel and plate.......................................151 5.8 Testing the heating pump.................................................. 89 5.34 Replacing non-return valve..............................................154 5.9 Testing the drain pump...................................................... 91 5.35 Replacing the Aquasensor...............................................156 5.10 Testing the water points electrically................................. 92 5.36 Folding down rinsing tank ...............................................157 5.11 Power cord.......................................................................... 94 5.37 Replacing pump sump .....................................................163 5.12 Replacing feed pipe ........................................................... 95 5.38 Replacing heating pump ..................................................165 5.13 Removing the worktop....................................................... 96 5.39 Replacing water points.....................................................168 5.14 Installing optional elements in the baskets ..................... 98 5.40 Replacing water softening system ..................................170 5.15 Installing childproof lock................................................. 103 5.41 Replacing the drain pump................................................172 5.16 Replacing / resetting door lock....................................... 104 5.42 Counterweight...................................................................173 5.17 Replacing side panels...................................................... 105 5.43 Attaching the rinsing tank................................................174 4 DIAGNOSTICS ............................................ 64 4.1 Malfunctions ....................................................................... 64 4.2 Result faults........................................................................ 65 4.3 Electrical faults................................................................... 76 4.4 Mechanical faults ............................................................... 76 4.5 Leaks ................................................................................... 77 4.6 Dishwasher functions / Software...................................... 78 5 TEST AND REPAIR..................................... 79 5.1 155_58300000149128_ara_en_c – 12.02.13 Seite 2 von 181 5.44 Transparent door ............................................................. 178 5.45 Loading appliance software ............................................ 179 5.46 Technical specifications.................................................. 181 155_58300000149128_ara_en_c – 12.02.13 Seite 3 von 181 1 INTRODUCTION 1.1 Purpose of the document The repair instructions: ► guide the service technician in troubleshooting and repairing domestic appliances 1.2 General symbols Symbol Meaning Special information ► assist the technical storeman in deciding which spare parts are probably required for the repair ► inform trainers and technical personnel about design, function, troubleshooting and repairs ► as supporting documentation support the training of the technical personnel Apart from the repair instructions the service technician uses the following documents: ► Parts list ► Exploded drawing ► Circuit diagrams The described troubleshooting and repair may be carried out a service technician only. These repair instructions are assigned to specific appliances and are valid for those appliances only. 155_58300000149128_ara_en_c – 12.02.13 Seite 4 von 181 1.3 Safety-relevant symbols Symbol Meaning General warning information Danger of electric shock Risk of being cut Risk of crushing Hot surfaces Risk of explosion Strong magnetic field Non-ionising radiation 155_58300000149128_ara_en_c – 12.02.13 Seite 5 von 181 2 SAFETY 2.1 Qualifications of service technicians The described activities may be carried out only by electrical engineers and electrical engineers for specific activities if they have been trained by BSH or an authorised establishment. 2.2 Identification of danger levels Identification Meaning DANGER Imminent danger which may result in death or serious injury if it is not avoided. WARNING Potentially imminent danger which may result in death or serious injury if it is not avoided. CAUTION Potentially imminent danger which may result in minor injury or damage to property if it is not avoided. 2.3 Identification of damage to property Identification NOTE Meaning Warning of potential damage to property 155_58300000149128_ara_en_c – 12.02.13 Seite 6 von 181 2.4 General safety instructions ► Read repair manual and follow the instructions included in it. ► Proceed systematically and follow the instructions for troubleshooting and repairs. ► When repairs are complete, check the effectiveness of the protecttive measures in accordance with VDE 0701 or the corresponding country-specific regulations and perform a function test. If the test is not passed, clearly identify the appliance as not safe and inform the operator in writing. The test for the effectiveness of the protective measures must be documented in a suitable manner. It is recommended to write down the measured values. ► Use only conductors which comply with the currently valid health and safety regulations at work. WARNING Exposed conductive parts may be live if a fault has occurred. Danger to life caused by electric shock! ► Disconnect the appliance from the power supply. ► Do not touch housing, frame or components. ► Use residual-current-operated circuit-breaker if tests have to be conducted while the appliance is live. ► Ensure that the resistance of the protetive conductor does not exceed the standardised values. CAUTION Risk of being cut on sharp edges. ► Wear protective gloves. DANGER ► Wear personal protective equipment. Exposed live parts Danger to life caused by electric shock! ► Disconnect the appliance from the power supply. ► Do not touch housing, frame or components. ► Use residual-current-operated circuit-breaker if tests have to be conducted while the appliance is live. CAUTION Charged capacitors Risk of injury from electric shock and startle response. ► Discharge capacitors before working on the appliance. ► Ensure that the resistance of the protective conductor does not exceed the standardised values. 155_58300000149128_ara_en_c – 12.02.13 Seite 7 von 181 NOTE Components which come into contact with electrostatic voltage will be damaged beyond repair ► Before carrying out any work, apply protective system to components susceptible to electrical discharge. ► Observe measures to protect the components susceptible to electrical discharge. NOTE Components which are replaced haphazardly will be damaged beyond repair ► Before replacing components, perform troubleshooting. ► Check systematically. ► Observe Technical Documentation. ► Do not replace components without reason. 155_58300000149128_ara_en_c – 12.02.13 Seite 8 von 181 3 CONSTRUCTION AND FUNCTION 3.1 Chapter describing design and function Overall view of the appliance with all components 155_58300000149128_ara_en_c – 12.02.13 1 2 3 4 5 6 7 Power module Heat pump Drain pump Overflow conduit / gutter Sealsystem Sump Outlet Valve 8 9 10 11 12 13 Water softener Counter weight Heat exchanger (optinally) Outlet hose Inlet hose, cold water Inlet hose, hot water – optionally Seite 9 von 181 3.2 3.2.1 Door sensor 3.2.2 Position of the door sensor Function of the door sensor Hall sensors (also known as Hall probes, after Edwin Hall) use the Hall effect to measure magnetic fields. A permanent magnet is inserted in the door lock. When the door is closed, the permanent magnet is positioned exactly over the Hall sensor. When the door is opened or closed, the strength of the magnetic field changes on the Hall sensor. The Hall sensor modifies its power input. The electronics detect whether the door is open or closed. If the power input is outside a defined range, this is detected by the electronics as a fault. The Hall sensor responds to the direction of the magnetic field. An incorrectly fitted permanent magnet or incorrectly polarised signal lines may result in wrong information being sent to the electronics. 1 Door sensor (Hall element) 2 Screw connection for door sensor The door sensor is situated in the centre at the top of the inner door. 155_58300000149128_ara_en_c – 12.02.13 Seite 10 von 181 3.3 Door lock/Childproof lock 3.3.2 Function of the mechanical childproof lock (optional) 3.3.1 Overall view of the mechanical door lock The mechanical childproof lock prevents the door from opening. Activation: Pull lever outwards and push to the right. Deactivation: Push lever all the way in. 1 Door lock 3 Mechanical snap lock 2 Mechanical childproof lock (optional) 4 Permanent magnet The door lock is mechanical. A snap lock in the container frame engages in a recess in the door frame. 155_58300000149128_ara_en_c – 12.02.13 Seite 11 von 181 3.3.3 Electronic door lock (optional) The appliance can be secured to prevent programmes from being ended unintentionally (e.g. faulty operation by children). Deactivating button lock: Hold down button B for approx. 4 sec. until CL goes out. When the programme ends (on the digital display), the button lock is cancelled. If there is a power failure, the button lock is retained. Whenever a programme is started, the button lock must be re-activated Activating button lock: Start the required programme. Hold down button B for approx. 4 sec. until CL is indicated on the digital display. If any button is pressed while the programme is running, CL is displayed. The programme cannot be ended (reset). 155_58300000149128_ara_en_c – 12.02.13 Seite 12 von 181 3.4.3 3.4 Safety system 3.4.1 Components in the safety system Safety switch – base pan ► AquaStop / water inlet valve ► Overflow channel and drainage duct ► Safety switch – base pan ► Intelligent electronics 3.4.2 Overflow channel and drainage duct 1 Safety switch 2 Polystyrene float The safety switch is mechanically connected to the polystyrene float. 1 Overflow channel 2 Drainage duct Leakage water is conveyed out of the container via the overflow channel, through the drainage duct and into the base pan. 155_58300000149128_ara_en_c – 12.02.13 Seite 13 von 181 3.4.4 Function The safety system is based on an “active” system. The electronics continuously monitor the safety switch in the base pan. Even if the appliance is switched off. If water runs into the base pan, the safety switch is actuated. The appliance switches on. The electronics detect that the appliance was switched on via the safety system and immediately activates pump off. The AquaStop- / water inlet- valve is deactivated. Error code E:15 or a flashing tap LED indicates the error to the customer. The appliance can no longer be operated until ► The cause has been rectified and there is no longer any water in the base pan. ► The appliance has been isolated from the power supply. Auxiliary function with devices with AquaStop: If leakage water runs into the base pan via the rinsing tank and the overflow channel, a further overflow can be prevented by switching on the drainage pump. If the supply hose is defective, water runs directly into the base pan via the external hose (leakage water hose). The AquaStop valve is deactivated. 155_58300000149128_ara_en_c – 12.02.13 Seite 14 von 181 3.5 Aquastop valve 3.5.1 Design The Aquastop valve is an electromechanical safety valve. The coarse and fine filters are located on the screw connection for the tap. Under the filters is the flow limiter. It limits the water flow to 2.5 litres. The Aquastop valve is enclosed by a housing. A leakage water hose (external hose –> jacket around the supply hose) runs from the housing into the base pan. The leakage water hose contains the water supply hose and the electric control cable for the solenoid valve. 3.5.2 Function In the idle state the coil is de-energised and the seal interrupts the water flow by the effect of the spring which presses on the armature. If the Aquastop valve is connected to the water mains, the water pressure also acts from behind on the seal and supports the sealing. If leaks occur in the area of the valve or supply hose, these are conveyed into the base pan via the leakage water hose. A polystyrene float activates the electronic safety system via a microswitch. The coil of the AquaStop valve is deactivated by the electronics and interrupts the flow of water into the appliance. 155_58300000149128_ara_en_c – 12.02.13 1 Coarse filter 5 Seal 2 Fine filter 6 Control cable 3 Flow limiter 7 Leakage water hose 4 Coil 8 Pressure hose – water supply Seite 15 von 181 3.6 Water inlet When the programme starts, the electronic control opens the Aquastop/water inlet valve (filling valve) for a short time. It is expected that water runs in. Electronics evaluates the impulses of the rotating flow sensor. Are these missing, an error code is indicated, the water tap LED flash and the program does not start. If impulses are received, the program starts. The drain valve is activated and the content of the heat exchanger is discharged into the container. By launching the circulation pump a smooth running filling starts. Is recognized that too little water is in the equipment, the AquaStop- / water inlet valve is opened. Water flows into the heat exchanger via the supply hose. The flow sensor and the free flow line are located in the water channel of the heat exchanger for the water supply. The water flows either into the granulate container (soften) or into the salt container (regenerate) via the regeneration valve in the water softening system. The outlet opening of the water softening system conveys the water back to the heat exchanger. 3.6.1 Bithermal connection (optional) Appliances with bithermal water connection have 2 supply hoses with AquaStop valve. The colour of the AquaStop valve identifies the difference between cold and hot water connections. The electronics control both valves separately. The appliance is supplied with either cold water or hot water. 155_58300000149128_ara_en_c – 12.02.13 1 Free flow line 7 Impeller wheel with flow sensor 2 Heat exchanger drainage valve 8 Supply hoses 3 Water softening system 9 AquaStop valve for hot water 4 Regeneration valve 10 AquaStop valve for cold water, optionally water inlet valve 5 Outlet opening 11 Heat exchanger water channel 6 Mixing piece Seite 16 von 181 3.6.2 Appliances with liquor reservoir (optional) If the appliance has an optional liquor reservoir, the heat exchanger at the end of the final rinse is filled only to 2/3 (2.1 l). This results in an amount of water of approx. 4.2 l in the appliance. 155_58300000149128_ara_en_c – 12.02.13 Seite 17 von 181 3.7 Heat exchanger The heat exchanger is used as the water inlet, water outlet and for storing the water which exchanges the heat. The diagram shows the components and connections of the heat exchanger. 1 Free flow line 7 Inlet from detergent-solution pump 2 Heat exchanger drainage valve 8 Water drainage (to the siphon) 3 Water drainage to the rinsing tank 9 Flow sensor 4 Inlet from water softening system Water outlet to the water softening system 10 Expansion opening 11 Drainage hose ventilation valve Water supply 12 Barrier 5 6 155_58300000149128_ara_en_c – 12.02.13 Seite 18 von 181 3.8 Flow sensor 3.8.1 Function 3.8.2 Design of mechanical reed contact The flow sensor is attached in the water channel of the heat exchanger (impeller wheel counter). The impeller wheel rotates as water flows through the channel. A small permanent magnet attached to the impeller wheel switches both contacts of a magnetic switch (Reed switch). As a result, electrical pulses are generated. These pulses are counted by the electronics. The electronics use these pulses to calculate the amount of water which flows into the appliance. 1 PCB with reed contact switch 2 Glass flask 3 Contact tongues Reed contact switches switch or interrupt circuits. They are contact tongues fused in a glass flask in a vacuum or an inert gas and which simultaneously form the contact spring and the armature. The name derives from the reed of woodwind instruments as it resembles the oscillating contact tongues. The contact tongues are manufactured from a ferromagnetic material (e.g. soft iron) coated with a noble metal. The contacts are actuated by an externally acting magnetic field which is generated electrically by an approaching permanent magnet or in an appropriate magnetic coil. The magnetic field activates the two contact tongues which then close the circuit. As soon as the magnetic field declines or a certain force drops below a minimum value, the spring effect opens the contact again. Reed contact switches are very sensitive to mechanical effects such as distortion. 1 PCB with Reed contact switch 2 Permanent magnet 155_58300000149128_ara_en_c – 12.02.13 3 Impeller wheel Seite 19 von 181 3.9 Expansion opening The heat exchanger is connected to the rinsing tank by the expansion opening. During the heating process the air in the rinsing tank expands. To prevent an overpressure and to ensure that the door is pressed on, air escapes via the expansion opening. If the door is opened while the washed utensils are warm, cold air flows into the appliance. If the door is closed, the air is heated by the warm washed utensils and expands. Overpressure occurs. This overpressure is released via the expansion opening onto the heat exchanger where it is dissipated via a small air hole. 1 Expansion opening in heat exchanger 155_58300000149128_ara_en_c – 12.02.13 Seite 20 von 181 3.10 If there is low pressure in the water line, water may flow out of the machine into the water supply system in the worst case scenario. Free flow line Only air is drawn in through the opening in the flow line and the return flow of water is prevented. 3.10.1 Flow characteristics in the free flow line 1 Free flow line 2 Air equalisation opening 3 Lug The free flow line is a water bend with an opening. The curved shape accelerates the water which flows past the opening. As a result, almost no water can escape through the opening even at a low water pressure. If water nevertheless escapes, it flows into the appliance. In the case of appliances up to FD8903 the water runs into the tank via the expansion opening. With FD8904 a lug was inserted into the heat exchanger. Escaping water flows into the heat exchanger. 1 Air equalisation opening This measure is stipulated by the deutsche Vereinigung des Gas- und Wasserfaches (DVGW). 155_58300000149128_ara_en_c – 12.02.13 Seite 21 von 181 3.11 1 Heat exchanger drainage valve Heat exchanger drainage valve 2 Outlet opening Appliances with active heat exchanger have a drainage valve. If this valve is actuated by the electronics, the water flows into the rinsing tank of the appliance via the outlet opening. 155_58300000149128_ara_en_c – 12.02.13 Seite 22 von 181 3.12 Water softening system 3.12.1 Water softening The water softening system (ion exchanger) is a container which is filled with fine-grained synthetic resin granules. This synthetic resin replaces calcium and magnesium ions in the water with sodium ions which are on its surface. 1 1 Ion exchanger 5 Salt dispenser cover 2 Water inlet 6 Float element (optionally) 3 Water outlet 7 Salt dispenser 4 Regeneration valve 8 Low salt sensor Synthetic resin The untreated water with its hardness constituents is conveyed via the synthetic resin. Calcium and magnesium are bonded to the surface of the exchange compound while sodium ions are released into the water. When all sodium ions have been replaced with ions of the hardness constituents, the capacity of the water softening system is exhausted and must be regenerated. Technical specifications: Capacity: Fine-grained salt Coarse-grained salt 155_58300000149128_ara_en_c – 12.02.13 ca. 1.3 ca. 0.9 kg Seite 23 von 181 3.12.2 Regeneration 1 Synthetic resin To make the ion exchanger functional again, a concentrated salt solution (sodium chloride) is conveyed from the salt dispenser by the water softener. Due to the large surplus the sodium ions from the salt solution displace the calcium and magnesium ions and attach themselves to the exchange compound. The ion exchanger is now “loaded” (regenerated) again and ready for use. 3.12.3 Regeneration cycle In dependence of the adjusted water hardness and the recognized quantity of water the regeneration cycle is steered by electronics. 155_58300000149128_ara_en_c – 12.02.13 Seite 24 von 181 3.13 3.13.2 Water passages in the water softening system Regeneration valve A 2-way valve (regeneration valve) is installed in the water softening system. This valve controls the water flow: ► Direct path into the ion exchanger When the regeneration valve is in the idle state, the water is conveyed directly into the ion exchanger and softened. ► Regenerate via the salt dispenser 3.13.1 Design 1 Valve with armature 2 Spring 3 Coil 1 155_58300000149128_ara_en_c – 12.02.13 Untreated water inlet regeneration valve with heat exchanger 2 Untreated water outlet regeneration valve with heat exchanger Seite 25 von 181 If the regeneration valve is actuated, the water flows into the salt dispenser and is enriched with salt. The water is conveyed back to the regeneration valve via the water channels of the water softening system. The brine solution flows into the ion exchanger. The granules are regenerated. The brine solution is conveyed into the rinsing tank via the heat exchanger and pumped out. 1 Untreated water inlet regeneration valve with heat exchanger 3 Salt water inlet regeneration valve with heat exchanger 2 Untreated water outlet regeneration valve with heat exchanger 4 Salt water outlet regeneration valve with heat exchanger 155_58300000149128_ara_en_c – 12.02.13 Seite 26 von 181 3.14 1 Low salt detection Water softening system 2 PCB with light barrier The PCB for the low salt indicator is attached with clips to the right side of the water softening system (front side of appliance). 1 Photodiode 2 Regeneration salt 3 Transmitter LED The salt level is detected via a light barrier. If the regeneration salt runs low, the line in the light barrier is freed and the electronics detect “Add salt”. If the low salt indicator appears, there is still so much salt in the appliance that some more regeneration processes may occur. According to this principle it is not necessary to fill the salt dispenser with water when switching on the appliance for the first time. Filling with salt tablets is system-dependently not recognized. 155_58300000149128_ara_en_c – 12.02.13 Seite 27 von 181 3.15 3.15.1 Fine filter cylinder Filter system Conventional fine filter systems are based on a round cylinder shape. If the cylinder is rolled out, the filter surface can be seen. 1 Fine filter cylinder rolled up 2 Fine filter cylinder rolled out The new fine filter system is based on a corrugated fine filter cylinder. If it is rolled out and smoothed, a 1.5x filter surface can be seen. 1 Fine filter cylinder 2 Surface filter, alternatively stainless steel or plasic 3 Coarse filter The 3-stage filter system is intended to prevent particles from getting into the rinsing circuit and impairing the pumping or spraying system. 155_58300000149128_ara_en_c – 12.02.13 1 Corrugated fine filter cylinder, rolled up 2 Fine filter cylinder, rolled out 3 Fine filter cylinder, rolled out Seite 28 von 181 3.16 Pump sump The pump sump is illustrated here with all mounted parts. 1 Aqua sensor (optionally) 2 Drain pump cover 3 Suction cap 3.16.1 Covers in the pump sump 1 Drain pump 5 Water switch (optionally) 2 Connection for lower spray arm 6 Water switch motor with pulse generator (optionally) 3 Supply pipe connection for roof sprinkler (optionally) 7 Heating pump 4 Supply pipe connection for upper spray arm The suction cap ensures that the pump has an optimized suction performance and flow performance. No air or dirt is drawn in. This cap should not be removed by the customer. The cover of the drain pump is used to channel the water. Without the cover the drain pump cannot build up any pressure. Customers may remove the drain pump cover for cleaning purposes. If the cover is not correctly attached, the water cannot be pumped out. 155_58300000149128_ara_en_c – 12.02.13 Seite 29 von 181 3.17 The water switch controls the water passage of the 3 spray levels and the filling of the optional water storage tank. Water switch It consists of a drive motor with cam plate, pulse generator and the locking disc. When the appliance is switched on, the motor is actuated via a triac. The cam plate is attached to the motor axle. The cam plate actuates a switch (pulse generator) which transmits pulses of different length and intervals to the electronics. If the electronics detect the standard setting, the water switch is initialised. The locking disc is rotated depending on the actuation. In doing so, holes of varying size release the water passage on the particular spray level or the connection of the hose to the optional water storage tank. The arrangement of the openings in the locking plate allows several levels to be actuated simultaneously or alternately. 1 Locking disc 5 Cog with cam plate 2 Seal 6 Cog 3 Pulse generator (switch) 7 Connection water storage tank (optionally) 4 Drive motor 155_58300000149128_ara_en_c – 12.02.13 Seite 30 von 181 3.18 3.18.2 Design of the heating pump: Heating pump 3.18.1 Overall view of the heating pump The heating pump contains the heater, temperature sensors and circulation pump in one housing. 1 2 1 Pressure connection 4 Heater connection 2 Circulation pump motor 5 Housing cover 3 Circulation pump motor connection 6 Intake connection 155_58300000149128_ara_en_c – 12.02.13 Pump housing with internal temperature shield made of metal Heating tube with NTCs 3 BLDC motor Seite 31 von 181 3.18.3 Function of the circulation pump The water is drawn in via the intake connection. The guide wheel guides the water evenly along the heating tube. The water is pumped to the water points via the pressure connection. While water is being circulated, the BLDC motor (Brushless DC Motor) signals different states to the power electronics via the current consumption of the individual windings: ► No water, ► too little water, snorkels ► adequate water level, (true running) ► pump blockage. Safety-relevant states, such as “Heating without water” or “Water temperature too high”, are detected and evaluated for the heating operation. 1 Pressure connection 5 2 Heating tube with NTCs 6 Intake connection 7 Pump housing with intake and pressure connections 3 BLDC motor 4 Pump wheel 155_58300000149128_ara_en_c – 12.02.13 Guide wheel If the pump is blocked, this is detected by the electronics. By several approach attempts, the pump try to loosen the blockage. If this is not successful, the running programme ends. A corresponding error code is saved in the error memory. Seite 32 von 181 If the appliance is connected to a hot water connection or solar equipment, the heater is switched off at a supply water temperature of > 70 °C. 3.18.4 Design of the heater 1 NTCs 2 Heating paths The heating paths are applied to a specially coated metal tube. The connections and two NTCs are integrated in the heating paths. The heating tube cannot be replaced separately. 3.18.5 Function of the heater / NTCs The water temperature is determined via the NTCs. In heating mode the electronics detect the temperature increase which occurs. 155_58300000149128_ara_en_c – 12.02.13 Seite 33 von 181 3.19 Drain pump If there is too little water in the pump area, pumping is stopped. If there is no cap in the pump sump, water pressure cannot build up. An error code is saved in the electronics. If the pump is blocked, this is detected by the electronics. By brief intermittent pumping, the pump attempts to loosen the blockage. If drainage is disrupted by a blockage or a kink in the drainage hose, pumping is stopped. An error code is saved in the electronics. Detection occurs via the current input of the pump during idling and the different load states. 1 Catch mechanism 3 Impeller wheel 2 Seal 4 Cable holder The water is drawn in via the water outlet opening of the pump sump. The impeller wheel pumps the water through the non-return valve into the drainage hose. While water is being pumped out, the BLDC motor (Brushless DC Motor) signals different states to the power electronics via the current consumption of the individual windings: ► No water, (idling) ► No pressure build-up (missing service flap) ► Pump blockage ► Blocked or kinked drainage 155_58300000149128_ara_en_c – 12.02.13 Seite 34 von 181 3.20 In each programme sequence in which the Aqua sensor is active the Aqua sensor is calbrated. Aqua sensor (optional) If calibration is defective, an error is written into the error memory of the power electronics. The measured value is set to “turbid” and a maximum programme sequence occurs No Aqua sensor installed ► There are appliances which are supplied without Aqua sensors. Nevertheless, the electronics check the Aqua sensor and save an error message. 1 Seal 2 Housing 3 PCB with light barrier A infrared diode and a phototransistor are located opposite each other in a U-shaped translucent housing on a board. The infrared diode transmits infrared light through the detergent solution flowing between the U-shaped housing. Depending on the turbidity, the light-sensitive base of the phototransistor becomes conductive. The measurement is analysed in turbidity ranges. The values are saved in the electronics. The Aqua sensor is active in the prerinse, the wash and at the end of the wash. The result of the Aqua sensor analysis influences the sequence of the rinse programmes. A wide range of programme structures is possible in the automatic programme. 155_58300000149128_ara_en_c – 12.02.13 Seite 35 von 181 3.21 Spray system The spray system consists of 3 spraying levels: the lower and upper spray arms and an optional roof shower head. Water is supplied to the upper spray arm and the roof shower head via the supply pipe attached to the inside of the tank rear panel. This pipe is connected to the pump sump by a direct plug-and-socket connection. The supply pipe has 2 separate water channels. As a result, the upper spray arm and the optional roof shower head can be actuated separately. The upper spray arm is attached by its inlet pipe directly to the top basket. The supply pipe is connected by a coupling. Optionally, the height can be adjusted by max. 3 levels (Rackmatik). The lower spray arm is connected by its bearings directly to the pump sump. It has a nozzle on the underside to clean the surface filter and to rinse dirt into the filter system. Appliances without a water switch do not have the roof shower head. Both spray arms can only be operated simultaneously. 1 155_58300000149128_ara_en_c – 12.02.13 Roof shower/roof spinner (optional) 5 Heating pump 2 Coupling for upper spray arm 6 Pump sump 3 Supply pipe 7 Lower spray arm 4 Water switch (optional) 8 Upper spray arm Seite 36 von 181 3.22 3.22.1 Cutlery drawer - option Basket system The basket system consists of 2–3 levels. The baskets differ in features and colour depending on appliance class. The table indicates the differences in features (date 07.2008). Vario VarioFlex – – optional – – VarioFlexPlus Top basket Ball ends Split additional cup racks, hinged Folding spikes Optimised glass holder Height-adjustable basket (3x Rackmatic) Basket handle Dosing assistant optional – 1 Bottom basket Ball ends Split additional cup racks, hinged Holder for long-stemmed glasses High basket back Basket handle 155_58300000149128_ara_en_c – 12.02.13 – optional – – – – – – Pull-out plate 2 Basket handle The cutlery drawer is attached at the very top of the rinsing tank. It is used as a holder for cutlery, other cooking accessories and also espresso cups. The utensils are washed primarily by the roof sprinkler. See Spray system. Seite 37 von 181 Loading example: 3.22.2 VarioDrawer Plus – optionally from 10/2011 1 Lowerable elements 3 Folding spikes 2 Lowering mechanism 4 Opening Starting from 10/2011 a VarioDrawer comes to the employment. This contains 2 rows flip tiens and lowerable files in the external areas, separately for right and left. 155_58300000149128_ara_en_c – 12.02.13 Seite 38 von 181 Representation of mobile elements and loading example: 3.22.3 Top basket 1 Knife shelf 4 Rackmatik plate 2 Folding spikes 5 Basket handle 3 Split, hinged additional cup racks The extendable top basket is loaded with smaller plates, glasses and cups. The utensils are cleaned by a spray arm under the top basket. When the top basket is pushed in, it docks with the supply pipe at the rear to make the water connection (see Spray system). 155_58300000149128_ara_en_c – 12.02.13 Seite 39 von 181 Representation of mobile elements: 155_58300000149128_ara_en_c – 12.02.13 Loading example: Seite 40 von 181 3.22.4 Bottom basket 1 Ball ends 4 Folding spikes 2 Holder for long-stemmed glasses 5 Cutlery basket (optionally) 3 Split, hinged additional cup racks 6 Basket handle The bottom basket is moved out of the appliance on rollers. The fixed lower spray arm cleans the utensils in the bottom basket (see Spray system). 155_58300000149128_ara_en_c – 12.02.13 Seite 41 von 181 Representation of mobile elements: 155_58300000149128_ara_en_c – 12.02.13 Loading example: Seite 42 von 181 Loading example: 155_58300000149128_ara_en_c – 12.02.13 Seite 43 von 181 3.22.5 Ball ends 3.22.9 Holder for long-stemmed glasses Ball ends are small balls on the tips of the folding spikes. If glasses or plates are placed on standard spikes, streaks may form in the area where the utensil touches the spike. The ball ends generate a minimum gap. As a result, utensils can be washed and dried without streaks. A folding bracket on the back of the bottom basket can be folded forwards so that long-stemmed glasses can also be arranged on a 2nd row. 3.22.6 Etagere An etagere is an additional hinged shelf in the baskets. As it is attached in the top of the basket, this produces another level (etage). There is space on this level for mocha cups or small objects. 3.22.7 Folding spikes These spikes can be folded down so that utensils can be arranged more flexibly. The spikes can be folded down on several levels or only on one level. 3.22.8 Rackmatik The height adjustment for the top basket is called Rackmatik. The adjustment can be on several levels (3 levels). The supply pipe has connections for one 3-level Rackmatik. The top basket can also be tilted to the right or left. The metal holders of the Rackmatik are pressed mechanically into the top basket. If the holders are bent open, the surface of the top basket may be damaged. 155_58300000149128_ara_en_c – 12.02.13 Seite 44 von 181 3.23 The tab drops into the tray. The spray arm in the top basket sprays the tray from below to dissolve the tab. Dosing assistant The bottom basket can no longer be pulled out over the dispenser. Food remnants can no longer drop into the dosage chamber and block it. 1 Top basket 3 Dispenser 2 Handle cover 4 Spray arm top basket The dosing assistant is an interaction between the arrangement of the dispenser and the handle cover in the top basket. The dispenser is situated in the middle of the door on the upper side of the door. In the top basket is the handle cover or tab drawer. 155_58300000149128_ara_en_c – 12.02.13 Seite 45 von 181 3.24 If the drain pump is actuated for draining, the water is pumped to the heat exchanger. The water flows to the drainage hose via the heat exchanger and out of the appliance. Water outlet A non-return valve is installed in the hose connection of the pump sump. This prevents the return of waste water into the pump sump. 1 Drain pump 5 Air duct 2 Inner drainage hose 6 Float chamber with float 3 Input water outlet 7 Drainage hose 4 Output water outlet 155_58300000149128_ara_en_c – 12.02.13 Seite 46 von 181 3.25 The non-return valve prevents water from running back out of the drainage area of the appliance. Non-return valve This prevents dirt residue, dirty water or detergent residue from flowing back into the rinsing circuit. 1 Pump sump 2 Non-return valve 155_58300000149128_ara_en_c – 12.02.13 3 Sealing lip Seite 47 von 181 3.26 Ventilation sequence During pumping, water is pumped to the drainage hose via the drainage channel of the heat exchanger / water inlet. A continuous water flow occurs. If the drainage is lower than the appliance, the water flows out of the appliance by suction effect even if the drain pump is no longer actuated. In the float chamber there is so much water that the float floats and the ventilation opening closes. The ventilation opening is released by the float as soon as the water flow in the water outlet decreases. The appliance cannot be drained while the liquor pump is deactivated as air can flow in via the ventilation opening. If the drainage hose is defective (blockage, kink), pressure builds up. Electronics detects the blockage over by drain pump An error code is saved in the failure memory. 1 Input water outlet 4 Float chamber 2 Output water outlet 5 Float 3 Air duct 6 Ventilation opening 155_58300000149128_ara_en_c – 12.02.13 Seite 48 von 181 3.27 Dispenser When the dispenser is filled with rinse aid, the cover is closed. It stays closed until it is manually opened again. The dosing chamber for detergent is opened mechanically in the appropriate washing section. Powdered detergent flows into the rinsing tank. Tabs drop into the handle cover (dosing assistant). 1 Coil 3 Dosing pump 1 Rinse aid dispenser cover with seal 5 Detergent dispenser cover 2 Anchor with switching mechanism 4 Low rinse aid sensor 2 Rinse aid outlet opening 6 Detergent dosing chamber 3 Rinse aid filler opening 7 Plastic bars 4 Detergent flap locking button 155_58300000149128_ara_en_c – 12.02.13 Seite 49 von 181 3.27.1 Function The actuator mechanism for the detergent cover is actuated via a coil. The coil is actuated via pulses from the power electronics. When the coil is switched on, the anchor is moved to the left. The anchor is connected by a plastic lever to the release lever of the detergent cover. When the actuation lever is turned, the detergent cover is released and opens. There is a switching mechanism between the coil anchor and the rinse-aid valve. The switching mechanism prevents rinse aid from being metered when the coil is initially actuated. When the detergent cover is opened, the mechanism switches similar to a “ballpoint mechanism”. The detergent cover is no longer actuated, but the dosing pump for rinse aid. With each pulse 1 ml of rinse aid is dispensed. The setting stage for the rinse aid corresponds to the pulses and the dispensed amount. To ensure that the rinse aid container drains, there is a scoop chamber. This is always filled when the appliance door is fully opened. The rinse aid flows out of this scoop chamber into the appliance. If the door is not fully opened, rinse aid may not flow into the appliance because the scoop chamber was not filled. 1 Coil 3 Anchor with switching mechanism 2 Release lever 4 Dosing pump A ventilation system is used to equalise the pressure in the dispenser. If the appliance door is opened, the actuating mechanism is “reset”. This causes the detergent cover to open first the next time the coil is actuated. If there is humidity left in the detergent dispenser and a detergent tablet is inserted, the tablet begins to dissolve slowly. 2 plastic bars in the dispenser prevent the detergent from “sticking” to the housing. 155_58300000149128_ara_en_c – 12.02.13 Seite 50 von 181 3.28 Low rinse-aid sensor The optical low rinse-aid sensor consists of a transmitter diode and a photo transistor. A light beam is transmitted from the transmitter diode to the receiver diode via a prism. If the dispenser is full, the light beam in the prism is scattered. The received signal is weaker than the transmitted one. 1 Receiver diode 2 Prism 3 Transmitter diode If the dispenser is empty, the light beam in the prism is reflected. The received signal is the same as the transmitted signal. The received signal is analysed and displayed via the power electronics. 1 Receiver diode 2 Prism 155_58300000149128_ara_en_c – 12.02.13 3 Transmitter diode Seite 51 von 181 3.29 Construction-partly the following spring system can be also used: Door springs The door springs are situated on the right and left under the base pan. The tensile force is transferred to the door hinge with a tension cord via a deflection lever. The tensile force of the door springs cannot be adjusted. The installed spring and the cable system automatically adjust themselves to the door weight. Springs with different tensile forces are available. They are marked by coloured points. The allocation to the released furniture fronts is shown in a table in the chapter replacing the springs. 1 Door spring 3 Deflection lever 2 Tension cord 4 Holder for tensioning cable 155_58300000149128_ara_en_c – 12.02.13 1 Holder for tensioning cable 3 Tension cord 2 Deflection lever 4 Door spring Seite 52 von 181 3.30 Variable hinge 3.30.1 Description The variable hinge enables fully integrated dishwashers to be installed in kitchens with a low base. The device moves the decor front upwards when the door is opened. As a result, the overhang at the bottom is smaller and passes over the base. The gap between the base and furniture door can be reduced. If appliances are installed higher, the visual appearance is significantly improved. 155_58300000149128_ara_en_c – 12.02.13 Seite 53 von 181 3.31 Foot adjustment Depending on the design, the appliances feature 3 or 4 appliance feet. The adjustable heights vary. Illustration 2: Built-in & built-under appliance Illustration 1: Free-standing appliance 155_58300000149128_ara_en_c – 12.02.13 Seite 54 von 181 3.32 Customer settings Requirement: Appliance is switched on 3.32.1 Button layout 3.32.2 Selection of the customer settings 3.32.4 Possible settings Range Warm water connection Hardness range Display A:00 – A:01 Intensive drying d:00 – d:01 Rinse aid r:00 – r:06 Buzzer B:00 – b:03 Language selection Auto Power OFF L:01 – L:19 EmotionLight E:00 – E:01 On-board computer Info Light C:00 – C:01 H:00 – H:07 P:00 – P-02 I:00 – I:01 Simultaneously press button A and the “Start” button Selection Switch on and off, factory setting: A:00 - Off 8 ranges, On - Off factory setting: H:04 Switch on and off, factory setting: d:00 - Off 6 ranges, On - Off factory setting: r:05 3 ranges, off factory setting: b:02 19 languages factory setting: L:01, German P:00 – Off, Emotion light on P:01 – Off after 1 minute, Emotion light off P:02 – Off after 120 minutes, Emotion light off Factory setting: P:01 On – Off factory setting: E:01 On On – Off factory setting: C:01 On On – Off factory setting: I:01 On Partly optional functions 3.32.3 Selection ranges 3.32.5 Saving the setting To select the range, press button A. Press “Start” button To change the value, press button C. 155_58300000149128_ara_en_c – 12.02.13 Seite 55 von 181 3.33 Emotion light (optionally) Emotion light is an internal light. 1 LEDs 2 Ribbon cable 3 Cap If the “Emotion Light” function is activated in the appliance menu, 2 LEDs light up when the door is opened. The interior light (Emotion Light) comes on when the door is opened irrespective of whether the ON/OFF switch is switched on or off. When the door is closed the light is off. If the door is open for longer than 60 min., the light switches off automatically. The interior light is lit only when the set value P:00 is selected. 155_58300000149128_ara_en_c – 12.02.13 Seite 56 von 181 3.34 Info light (optional) The user is provided with additional information by fully integratable models with a programme status display visible from the outside (info light). The info light consists of an LED and a fibre-optic cable. The light is bundled via the fibre-optic cable and is projected as a red light spot on the subsurface in front of the dishwasher while the programme is running. The info light is attached between the inner and the outer door on the right hinge plate and is actuated by the module. A LED C Light spot B Fibre-optic cable D Subsurface 155_58300000149128_ara_en_c – 12.02.13 Seite 57 von 181 3.35 TimeLight (optional) TimeLight projects user information about the operating state of the appliance for fully integrated models onto the floor in front of the appliance. Function: An LED radiates light which hits a condenser lens. The function of this lens is to collimate the incoming light to ensure that the LCD panel is evenly illuminated. The LCD panel has a resolution of 34 x 34 pixels. The graphic information is deflected via mirrors. The TimeLight projection module is available only as a complete module. 1 155_58300000149128_ara_en_c – 12.02.13 LED 4 Mirror 2 Condenser lens 5 Projection lens 3 LCD panel 6 Housing Seite 58 von 181 Projection process: 34 x 34 pixel 1 Projection module in the base plate 4 Projection surface 2 Deflection mirror in the base plate 5 Base panel 3 Outer door 155_58300000149128_ara_en_c – 12.02.13 Seite 59 von 181 3.36 Power module NOTE 3.36.1 Position of the components Electrostatic sensitive devices Components will be destroyed if touched ► Before carrying out any work, apply protective system to components susceptible to electrical discharge. ► Observe measures to protect the components susceptible to electrical discharge. 1 2 3 4 5 6 7 8 TH401 = water points TH403 = reserve Optionally: Valve water storage tank / Aqua stop valve warm water connection TH404 = heat exchangerdrainage valve (optionally) TH405 = regeneration valve TH402 = filling valve K201 = reversal relay circulation pump / drain pump K202 = reversal relay circulation pump / drain pump T412 = coil - dispenser 155_58300000149128_ara_en_c – 12.02.13 9 K304 = inrush current limiter 10 K100 = bistable relay, security system 11 K303 = heater 12 13 K305 = heater zeolith K301 = relay security 14 Varistor, overvoltage protection 15 16 Seite 60 von 181 3.37 Power cords – country versions 3.37.1 Power cord The power cord has a cold appliance system connection and is enclosed with the appliance. When the appliance is switched on for the first time, the cable must be connected to the back of the appliance 3.37.2 Country versions Different power cords are offered as optional accessories via Sales. Incorrect connected loads! Destruction of the appliance ► If a power cord is replaced with a power cord with a different plug, check the connected loads of the appliance with the supply voltages and frequencies WARNING of the particular country. 3.37.3 Extension leads 3 metre extension cables are available from customer service. These are currently released by PG. Material number EU version: 644533 Material number GB version: 644534 155_58300000149128_ara_en_c – 12.02.13 Seite 61 von 181 3.38 D-bus2 / appliance software DANGER The software can be manually imported (flashed). A connection with the D-bus2 is established via the UDA. CAUTION ► Disconnect the appliance from the power supply. Voltage peaks with the release/connecting the plug contacts Destruction of the control module or the piezo power supply unit (optional) by net potential on the ground ► Do not touch housing, frame or components. wire of the bus system. ► Use residual-current-operated circuit-breaker if tests have to be conducted while the appliance is live. ► Disconnect the appliance from the power line before release/connecting plug connectors. Exposed live parts Danger to life caused by electric shock! ► Ensure that the resistance of the protective conductor does not exceed the standardised values. Communication between the electronically components is via a D-bus2. The D-bus2 consists of a 3-pole line system. The 3 lines are connected as follows: • 13,5 V d.c. via GND • GND (possibly power potential) • Data line 155_58300000149128_ara_en_c – 12.02.13 Seite 62 von 181 3.39 Weight Free-standing appliances have a weight in the rear area of the base pan. This prevents the appliance from tipping over if the door is opened and the baskets pulled out. There are 2 different concrete weights: Appliances with cutlery drawer: 6.5 kg Appliances without cutlery drawer: 5.5 kg Appliances with Zeolith additional heating system: 2.4 Kg 1 Counterweight 155_58300000149128_ara_en_c – 12.02.13 Seite 63 von 181 4 DIAGNOSTICS 4.1 Malfunctions Fault Tablet does not dissolve. Cause Spray arm stiff, sticking, touches container rear side. Fault correction Check function of the upper spray arm (Use of glass door, material number: 81cm: 341333; 86 cm: 341334). Tablet does not fall into the Tolerances basket handle on 86 cm appliances. Insert tablet chute (material number 614935) into top basket. Program Stops; Door lock not correctly closed, there door lock Program cannot be started engaged. Closing force too highly. Program suspends Close door firmly thereby the door lock works normally again. Closing force reduction by exchange of upper piping 155_58300000149128_ara_en_c – 12.02.13 Seite 64 von 181 4.2 Result faults Fault Poor rinsing result. Cause • Tablet does not fall into the basket handle on 86 cm appliances. • Spray arm stiff, sticking. • • • non-return valve defectively/blocked/clogs Dispenser does not open, because Tab blocks the dispenser cover, Tab upright inserted remainders in the dispenser • Missing cover of water softener in AU models Unsatisfactory washing Lower spray arm blocked on the blow-out cap of the zeolite result in the bottom basket container. of zeolite appliances. On account of an increased number of enquiries concerning the washing result of the series GV640, the possible reasons for the “poor washing result” complaint and information on possible remedies are listed below. Faults which can be clearly attributed to operating faults, as well as inadequate maintenance, must not be claimed under the warranty. Appropriate use and maintenance instructions can be found in the indicated chapters in the Instructions for use and Quick reference guide . • • • • Fault correction • Insert tablet chute (material number 614935) into top basket. • Check that the spray arms function (Use of glass door, material number: 81 cm: 341333; 86 cm: 341334) -> replace spray arm. • Examine, release it • Advise customer, insert Tab correctly • Spraying arm blocked, dishes, smell donors in grip cap - > advise customer • AU models are partially coated with a "dummy" equipped softener. Screw on lid. Check that the cap is secure. It must be locked all the way. Does the problem persist, sporadically or at specific intervals? Were different programmes or detergents used or tested? Has the problem been occurring since a specific time (new utensils, change in detergent, ...)? Are only utensils in certain areas (only top/bottom basket, only corner areas, ...) affected? The performance test must be conducted in the customer service test programme using the “glass door”. From experience it is important to scrutinise not only the fault description but also the circumstances of the occurrence on acceptance of the order and to mention these in the order. 155_58300000149128_ara_en_c – 12.02.13 Seite 65 von 181 1. Residue on the utensils Fault description Cause Food remnants or sandy residue Utensils placed too closely together, overfilled. Spray arm blocked by utensils or cutlery. Remedial action Observe correct arrangement of utensils (arrange according to Fig. 1, Fig. 2 and Fig. 3). Arrange utensils so that spray arm can rotate without obstruction. (arrange according to Fig. 2 and Fig. 3); see Utensils Utensils precleaned too intensely; sensors therefore decide on weak Do not prerinse utensils; remove only large food remnants. programme sequence. Stubborn soiling cannot be completely removed. Programme recommendation Eco 50°. Filter not locked in the pump sump or incorrectly inserted. Insert and lock filter correctly; see Maintenance and care Spray arm nozzles, roof shower head blocked (e.g. lemon pips, etc.). Clean nozzles and roof shower head and insert/lock filter correctly; see Maintenance and care Coarse, micro and fine filter dirty. Clean filters; see Maintenance and care Spray arm bearings do not move smoothly (dirt around the bearings). Clean parts, show customer how to insert filter correctly. Spray arm or supply pipe deformed -> spray arm strikes the basket or the docking site. Replace spray arm. Waste-water pump blocked. Check waste-water pump; see Eliminating faults yourself Dirty water runs back into the appliance -> re-soiling. Check draining, check non-return valve for leaks. Top basket on right and left not set to same height. Set top basket to same height using side levers. Utensils unfavourably arranged (very large utensils e.g. pans in the bottom basket), avoid contact points, prong rows bent. Arrange utensils so that spray jets can reach surface of utensils (arrange according to Fig. 2 and Fig. 3). Tall narrow receptacles are not rinsed adequately in the corner area. Do not place tall narrow receptacles too obliquely or in the corner area (arrange according to Fig. 2 and Fig. 3). 155_58300000149128_ara_en_c – 12.02.13 Seite 66 von 181 Fault description Cause Remedial action Detergent residue Detergent dispenser cover blocked by utensils (cover does not open fully). Check detergent dispenser function, detergent cover must not be obstructed by utensils. Do not place any utensils or aroma dispensers in the dosing assistant. Water stains on plastic parts Detergent dispenser cover is blocked by the tablet. Advise customer, insert tablet correctly (flat, not upright). Tablets used in the Quick or Short programme. -> Dissolving time of the detergent is not reached in the selected short programme. Advise customer, dissolving time of the tablets too long. Detergent residue in final rinse; detergent-solution carry-over. Check draining, check non-return valve for leaks. Detergent very lumpy, washing effect and dissolving performance are reduced after a prolonged storage time. Advise the customer. Droplet formation on plastic surface is physically unavoidable. Plastics do not store heat. − Use more intensive programme (more water changes); see Programme overview After drying, substances in water are visible. − Note inclination when arranging utensils. Use detergent powder or select a more intensive programme. Always insert tablet just before the programme starts. − Use rinse aid, if required increase see Rinse aid. − If required, increase softening setting; see Water softening system Water residues Wrong loading Soap-like layering of ingredients of food residue and lime. Coloured (yellow, orange, brown), easily removable, soapy Because of tolerances for combined detergents (3 in 1 or higher) can residue in the interior make it necessary to use the water softener already at a water hardness of 16 ° dH. Correct sequence for eliminating consider Fig 4 Residue in the pull-out rails Clean by hand, - for the upper basket use the modified pull-out rails with mat.no. 708086 - for the cutlery drawer use mat.no. 687970 Detergent and food remnants are deposited due to design. 155_58300000149128_ara_en_c – 12.02.13 Advise customer and contrary to the indication of the detergent manufacturer activate the water softener additionally Seite 67 von 181 2. Coatings: Fault description Cause Remedial action Wipe-clean or water-soluble coatings in the container or on the door Detergent substances are deposited. These coatings cannot usually be removed with chemicals (appliance cleaner, ...). Change detergent brand. Clean appliance mechanically. Water softening system set marginally; fault description occurs cyclically Increase softening setting “White coating on container floor”. and change detergent if required. Regeneration salt on the utensils: − Leaking salt dispenser cover. Advise customer, eliminate leak. − Leaking regeneration valve. Check regeneration valve or valve seat (customer service programme). Detergent residue in the final rinse; detergent-solution carry-over. Check detergent dispenser function, detergent cover must not be obstructed by utensils; Wrong programme selected. (Quick programme selected) Select suitable programme. see Programme overview Initial clouding of glass -> can only apparently be wiped off. Damage to utensils 155_58300000149128_ara_en_c – 12.02.13 Seite 68 von 181 Fault description Cause Remedial action White, stubborn coatings; limescale on the utensils, container or door Detergent substances are deposited. These coatings cannot usually be removed with chemicals (appliance cleaner, ..). Change detergent brand. Hardness range incorrectly set or untreated water hardness greater than 50 °dH. Check residual hardness in the cleaning and final rinse cycles and set water softening system according to instructions for use. Top up salt; see Water softening system Water softening system is not being regenerated. Check function of the regeneration valve in the customer service programme. 3in1 detergent or bio/eco detergent not effective enough. Set water softening system according to instructions for use; use separate agents (proprietary detergent, salt, rinse aid); see Water softening system Underdosage of detergent (verification with Minilabor mat. no. 340070). Advise customer; increase detergent dosage, change detergent. Wrong programme selection (programme too weak) selected. Advise customer; correct programme selection; see Programme overview Too low rinsing temperature. Select programme with higher washing temperature; see Eliminating faults yourself Too little detergent. Use suitable detergent at correct dosage. Starch deposits on the utensils Tea or lipstick residue on the utensils Clean appliance mechanically. Utensils precleaned too intensely; sensors therefore decide on weak Do not prerinse utensils; remove only large food remnants. programme sequence. Stubborn soiling cannot be completely removed. Programme recommendation Eco 50°. Coloured (blue, yellow, brown), difficult to remove to nonremovable coatings in the container or on the door Unsuitable detergent. Change detergent. Film formation consisting of ingredients from vegetables (e.g. cabbage, celery, potatoes, noodles, ..) or the tap water (e.g. manganese). Can be partly removed with machine cleaner (mat. no. 311313) or mechanical cleaning. Coatings are harmless. Film formation caused by metallic components. Known for silver or aluminium utensils. Can be partly removed with machine cleaner (mat. no. 311313) or mechanical cleaning. 155_58300000149128_ara_en_c – 12.02.13 Seite 69 von 181 3. Discolouration: Fault description Cause Remedial action Coloured (blue, yellow, brown), shimmering, difficult to remove to non-removable discolouration in the container or on the door Film formation consisting of ingredients from vegetables (e.g. cabbage, celery, potatoes, noodles, ..) or the tap water (e.g. manganese). Can be partly removed with machine cleaner (mat. no. 311313) or mechanical cleaning. Mechanical removal with “Vienna chalk” (mat. no. 311136) usually possible. Coatings are harmless. Film formation caused by metallic components. Known for silver or aluminium utensils. Can be partly removed with machine cleaner (mat. no. 311313) or mechanical cleaning. Wash programme too weak. Select different wash programme; see Eliminating faults yourself Too low rinsing temperature. Select programme with higher wash temperature. Discoloration on plastic parts Utensils precleaned too intensely; sensors therefore decide on weak Do not prerinse utensils; remove only large food remnants. programme sequence. Stubborn soiling cannot be completely removed. Programme recommendation Eco 50°. 4. Streaking on glasses and cutlery Removable streaking on glasses Too much rinse-aid. and cutlery Set rinse-aid amount to lower level; see Rinse aid Glasses with metallic appearance No rinse aid added or setting too low. Add rinse aid and check dosage (recommendation level 4-5); see Rinse aid Non-return valve leaking. Check non-return valve for leaks. Detergent residue in the final rinse. Detergent dispenser cover blocked by utensils (cover does not open fully). Check detergent dispenser function, detergent cover must not be obstructed by utensils. Do not place any utensils or aroma dispensers in the dosing assistant. Utensils precleaned too intensely; sensors therefore decide on weak Do not prerinse utensils; remove only large food remnants. programme sequence. Stubborn soiling cannot be completely removed. Programme recommendation Eco 50°. 155_58300000149128_ara_en_c – 12.02.13 Seite 70 von 181 5. Damage to utensils/water-insoluble residue Fault description Cause Remedial action Initial or existing irreversible clouding of glass Glasses not adequately dishwasher-proof (glasses are usually only suitable for dishwasher). Advise the customer. Reduce main causes of glass corrosion: − Use dishwasher-proof glasses. − Avoid long steam phase (standing time after wash cycle ends). − Use programme at lower temperature. − Set water softening system according to the water hardness (if required one level lower); see Water softening system − Use detergent with glass protection component. 155_58300000149128_ara_en_c – 12.02.13 Seite 71 von 181 6. Rust Fault description Cause Remedial action Rust marks on cutlery Cutlery not adequate corrosion-resistant. Knife blades are frequently more severely affected. Use corrosion-resistant cutlery. Cutlery infected by extraneous rust from rusting parts (metal lid, damaged utensils basket, etc.). Do not wash rusting parts. Salt content in the rinsing water too high, as salt dispenser lock not fastened firmly or salt was spilled while being refilled. Fasten salt dispenser lock firmly or remove spilled salt (by prerinsing cycle). Large contact surfaces between cutlery and too little inclination of e.g. spoons prevent the water from draining and cause staining. Arrange cutlery so that there are as few contact surfaces as possible. (Arrange according to Fig. 1 and Fig. 2). Coarse, micro and fine filter dirty. Clean filters; see Maintenance and care No rinse aid added or setting too low. Add rinse aid and check dosage (recommendation level 4–5); see Rinse aid Stains on the cutlery (Combination detergents have a lower final rinsing effect than separate rinse aids). Hardness range incorrectly set or untreated water hardness greater than 50 °dH. Check residual hardness in the cleaning and final rinse cycles and set water softening system according to instructions for use. Top up salt; see Water softening system Minor discolouration or residue at the contact points are physically induced and unavoidable. Minimisation possible by means of the points stated in this section. 155_58300000149128_ara_en_c – 12.02.13 Seite 72 von 181 Figures: Fig 1 A – Arrange knives and other sharp-edged or pointed cutlery with the blades face down to prevent accidental injury. B – Do not place items of cutlery on top of each other. Correct arrangement certainly aids stain-free cutlery. C – Arrange spoons and ladles at an incline. This will prevent accumulation of water and stains. Fig 2 A – Do not place utensils on top of each other. Otherwise, parts on top will not be sprayed from below with adequate water. B – Avoid large contact points between utensils. This prevents food remnants and stains on the utensils. C – Do not overload cutlery basket. Minimise contact points between items of cutlery. This ensures stain-free cutlery. D – Arrange hollow receptacles in such a way that water cannot collect inside. Do not let utensils project through the utensils basket. This ensures that the spray arm is not blocked. 155_58300000149128_ara_en_c – 12.02.13 Seite 73 von 181 Fig 3 A – Arrange hollow receptacles in such a way that water cannot collect inside. B – Do not place utensils on top of each other. Otherwise, parts on top will not be sprayed from below with adequate water. C – Arrange cups and bowls at an incline. This prevents water from accumulating in their base area. D – Do not place hollow receptacles too obliquely and do not place directly in the corner area. This ensures that they can be flushed out properly. E – If appliances feature a tablet collecting tray, do not load it with utensils or aroma dispensers, otherwise the detergent dispenser will be obstructed. Do not let utensils (e.g. small ladles) project through the utensils basket. This ensures that the spray arm is not blocked. 155_58300000149128_ara_en_c – 12.02.13 Seite 74 von 181 Fig 4 Eliminate the baskets in the following order: 1 – Lower basket. 2 – Upper basket 3 - cutlery drawer (optionally). 155_58300000149128_ara_en_c – 12.02.13 Seite 75 von 181 4.3 Electrical faults Fault Low salt indicator is constantly lit. 4.4 Cause Salt tablets used. Fault correction Advise customer: do not use salt tablets. Mechanical faults Fehler Door cannot be closed. Ursache Catch locked by the door lock. Fehlerbehebung Close door firmly until the lock is functioning normally again. Cutlery drawer clamps FD 9006 to FD 9010 incl. Change the pull out rails of the cutlery drawer (Mat.Nr. 668719). 155_58300000149128_ara_en_c – 12.02.13 Seite 76 von 181 4.5 Leaks Fault Cause Fault correction Leakage under heat exchanger Expansion opening does not bolt correctly. Consider the sequence when assembling the heat exchanger: • See also to chapter „ replacing heat exchanger” Error E:15 generated from Minimal leakage in the water softener can generate error leakage under water E:15 after many wash cycles. softener in FD 9110 ~ 9205. 155_58300000149128_ara_en_c – 12.02.13 Change water softener complete: - See also to chapter „ replacing water softener system” Seite 77 von 181 4.6 Dishwasher functions / Software Fault After switching on the dish washer, it begins with ECO 50 programme. Cause Fault correction Advise customer: EU-directive (EU1275 / in 2008, With KI 59 a new software is implemented. The default “start program” is always ECO, no matter which programme conformance index 011) specify this programming. was chosen in the last washing cycle. 155_58300000149128_ara_en_c – 12.02.13 Seite 78 von 181 5 TEST AND REPAIR 5.1.2 5.1 Testing water hardness in the appliance Operating the appliance with the water softening system switched off Some faults require that the water hardness is determined in the appliance. Check the following beforehand: If the water softening system is deactivated, detergent tablets with salt replacement substances should be used. Note what is written on the packaging. Is regeneration salt used? Has regeneration salt been added? The chemical components of multifunction tablets bind the limescale in the water to themselves. These are effective up to approx. 21° dH. Note the product description of the manufacturer. Is the water softening system switched on? Test the water hardness of the supply water. Has the correct degree of hardness been switched on? Does the customer use tablets (which ones)? 5.1.1 Testing while the water softening system is active 5.1.3 Advising the customer If the water hardness is above the range within which the utilised tablets have a softening effect, advise the customer to use the regeneration system with regeneration salt. Start test programme and let the appliance fill up to the first pause, checking visually. If the customer uses tablets without salt replacement substances, suggest that special salt is used. Determine water hardness in the appliance using the water hardness test. The appliance must be set correctly. Approx. 5° to 7° dH should be measured provided the water softening system is intact and regeneration cycles have been set correctly. If the value is significantly higher, test the water softening system. 155_58300000149128_ara_en_c – 12.02.13 Seite 79 von 181 5.1.4 Checking water supply The electronics check the water level in the appliance during the prerinse and wash cycles via the heating pump (uniformity check). If required, the water is topped up. The filling capacity for the clear rinse is filled during the inter-mediate rinse cycle and stored in the heat exchanger. The capacity is measured via the pulses of the impeller flow meter only. A uniformity check during the final rinse cycle no longer occurs. If there is too little water left in the heat exchanger for the final rinse cycle, a poor cleaning and/or drying result can be expected. Reasons for too little water may be: ► – Water pressure / - flow too low (supply hose kinked, angle valve calcified, flow rate Aquastop) ► – Heat exchanger drainage valve leaking 5.1.5 Water pressure too low There is a ventilation opening in the free flow section. Usually the water in the flow section flows past the opening. If the water pressure is so low that the impeller flow meter is just responding, the water no longer flows past the opening. Leakage water flows via the overflow channel to the expansion opening into the rinsing tank. The heat exchanger is not completely filled. 1 Leakage water 2 Expansion opening 3 Overflow channe l Since FD 8905 an additional barrier (bar) has been inserted into the over-flow channel of the heat exchanger. This barrier ensures that leakage water flows out of the free flow section into the heat exchanger. Note: Water in the heat exchanger is therefore not softened. Limescale deposits on the utensils may be an indication of this. 155_58300000149128_ara_en_c – 12.02.13 Seite 80 von 181 The heat exchanger is filled during the wash cycle. The filling should be prewarmed and be available for the intermediate rinse or final rinse cycle. New heat exchanger: 5.1.7 Consequence A filled heat exchanger is expected for the final rinse cycle (2.5 l of 3.1 l filling capacity). If water ran into the appliance for the reasons stated above, it was pumped out after the wash cycle. The power consumption of the heating pump indicates whether there is too little water in the appliance. The programme continues running without heating and error E08 is stored. In the worst case scenario the heating may function, but there is insufficient water in the appliance for adequate circulation. The appliance heats up, but the final rinse liquor does not completely reach the utensils. There is no pressure to wet and therefore to heat the utensils. 5.1.8 1 Leakage water 2 Overflow channel 3 Bar Diagnosis 1. Start customer service test programme and observe water inlet and filling of the heat exchanger. 2. Check heat exchanger drainage valve for leaks. Remedial action: 5.1.6 Heat exchanger drainage valve defective If the drainage valve of the heat exchanger is leaking, the contents run prematurely into the rinsing tank. When drainage next occurs, the complete amount of water is not available in the tank. ► Provide adequate water supply pressure. ► Check shut-off valve. ► Check strainers in the Aquastop valve. ► Prevent kinked supply hose. ► Clean the drainage valve. 155_58300000149128_ara_en_c – 12.02.13 Seite 81 von 181 Removing/installing the appliance 5.1.9 Required tools Tools: Material number: Special tool for threaded ring on the salt dispenser; cover on the expansion opening; exhaust air channel, water storage tank, water inlet bolt. 341805 5.1.10 Removing water ► To drain the heat exchanger and water storage tank, start any programme. After checking the water impeller turn off the tap. Heat exchanger and water storage tank are drained. Then reset to pump out the residual water. ► Using the suction syringe, remove remaining water from the pump sump. Dish washer with zeolite additional heating system ► With devices with zeolite additional heating system must be taken residual waters out of the equipment inside. Equipment residual water into the zeolite container, can be destroyed the material contained in it. 155_58300000149128_ara_en_c – 12.02.13 Seite 82 von 181 5.2 Testing/replacing the door sensor 5.2.2 Removal Requirement: ► Outer door removed. ► Fascia removed. ► Right side panel removed. 5.2.1 Measuring the voltage ► Very carefully remove the plug from the door sensor. Do not pull on the wires. ► Measure voltage on both contact of the power cord. ► If 13.5 V DC is supplied to door sensor, the power module and the connection cable works properly -> replace door sensor. ► If this voltage is not applied, measure the voltage on the power module. ► No voltage -> replace power module. 3. Door sensor. ► Voltage available -> measure resistance of the connection cables between power module and the connections of the component. Rectify interruption. 4. Loosen the two Torx 10 screw on the side of the door closure recess. Panel of door closure recess ► The panel of the door closure recess may become detached when the door sensor is removed. Hold firmly. Measure voltage on the module ► When the plug is connected, the supply voltage can be measured from the front on the two yellow wires on the power module. When the plug is removed, the main switch is inoperative. 5.2.3 Installation Installation is in reverse sequence. The plugs are coded. 155_58300000149128_ara_en_c – 12.02.13 Seite 83 von 181 5.3 Testing dispenser electrically Requirement: ► Outer door removed. 5.3.1 Measuring the coil Technical specifications EU: Pulse voltage of coil: 320 V Frequency: DC Resistance: 11 kΩ ± 1 kΩ Rinse aid capacity: 80 ml Rinse aid amount at setting 1–6 1 ml per setting Technical specificationsUSA: Pulse voltage of coil: 165 V DC Resistance: 2,67 kΩ ± 210 Ω Rinse aid capacity: 80 ml Rinse aid amount at setting 1–6 1 ml per setting Technical specifications EA (East Asia): Pulse voltage of coil: 280 V DC Resistance: 8,4 kΩ ± 800 Ω Rinse aid capacity: 80 ml Rinse aid amount at setting 1–6 1 ml per setting Technical specifications TC: 1. Disconnect plug-and-socket connection. Measure resistance on the coil. 155_58300000149128_ara_en_c – 12.02.13 Pulse voltage of coil: 155 V DC Resistance: 2,67 kΩ ± 210 Ω Rinse aid capacity: 80 ml Rinse aid amount at setting 1–6 1 ml per setting Seite 84 von 181 5.4 Checking EmotionLight (optionally) Requirement: √ Side panel on right removed √ Top cover of power module removed 1. Loosen plug-and-socket connection and measure voltage at power module contacts K10.10.5-6 Technical specifications: Supply voltage: 155_58300000149128_ara_en_c – 12.02.13 13,5 V DC Seite 85 von 181 5.5 Testing the regeneration valve electrically Requirement: Technical specifications EU: Nominal voltage: 230-240 V Frequency: 50/60 Hz ► Side panel on left removed. Resistance: 2 kΩ ± 500 Ω 5.5.1 Technical specifications USA: Measuring the coil Nominal voltage: 120-127 V Frequency: 60 Hz Resistance: 660 Ω ± 10% Technical specifications TC: Nominal voltage: 110V Frequency: 60 Hz Resistance: 550 Ω ± 10% 1. Disconnect plug-and-socket connection and measure the resistance. 155_58300000149128_ara_en_c – 12.02.13 Seite 86 von 181 5.6 Testing heat exchanger drainage valve electrically Requirement: ► Side panel on left removed. 5.6.1 Technical specifications: Nominal voltage: 230-240 V Frequency: 50/60 Hz Resistance: 2.2 kΩ ± 500 Ω Measuring the coil 1. Disconnect plug-and-socket connection and measure the resistance. 155_58300000149128_ara_en_c – 12.02.13 Seite 87 von 181 5.7 Testing Aquastop valve electrically 1. Loosing locking lever 2. Fold the Cover with the inlet hose outward. Technical specifications EU: Nominal voltage: 220 ~ 240 V Frequency: 50/60 Hz Resistance: 4.2 kΩ ± 1 KΩ 1. Disconnect plug-and-socket connection and measure the resistance. Technical specifications TC / USA: Nominal voltage: 110 ~ 127 V Frequency: 60 Hz Resistance: 990 Ω ± 50 Ω 155_58300000149128_ara_en_c – 12.02.13 Seite 88 von 181 5.8 Testing the heating pump 5.8.2 Measuring NTC resistance The NTC resistance value is measured on the heating contacts of the heating pump. Measured values when NTCs intact and at 25 °C: Contact 4 – 5: approx. 10 KΩ ± 1 KΩ Contact 5 – 6: approx. 10 KΩ ± 1 KΩ Contact 4 – 6: approx. 20 KΩ Measured at 25 °C Resistance measurement of the NTCs ► The measurement of the NTC must result in a symmetrical value. 5.8.1 Measuring the heater resistance The heater resistance is measured on the heating contacts of the heating pump. Measured values when heater intact EU: Contact 2 – 3: approx. 19 Ω ± 2 Ω Measured values when heater intact TC / USA: Contact 2 – 3: 155_58300000149128_ara_en_c – 12.02.13 ca. 8,9 Ω ± 2 Ω Seite 89 von 181 5.8.3 Measuring winding resistance of the BLDC motor Measure winding resistance at 25° on the winding contacts of the heating pump. Technical specifications: approx. 41.5 Ω ± 4 Ω or approx. 53.5 Ω ± 4.5 Ω according to manufacturer Resistance: Technical specifications: 12 Ω bis 14 Ω Resistance: Resistance measurement ► The resistance values are approx. values. There must be symmetry for all measurements (same resistance values). 155_58300000149128_ara_en_c – 12.02.13 Seite 90 von 181 5.9 Testing the drain pump 5.9.1 Measuring winding resistance of the BLDC motor Measure winding resistance on the winding contacts. Technical specifications: approx. 80,5 Ω ± 5 Ω Resistance: Resistance measurement ► The resistance values are approx. values. There must be symmetry for all measurements (same resistance values). 155_58300000149128_ara_en_c – 12.02.13 Seite 91 von 181 5.10 Testing the water points electrically Requirement: ► Side panel on right removed. 5.10.1 Measure water points motor (simple measurement) Technical specifications EU: Nominal voltage: 230–240 V Power input: 7 W / 4W Frequency: 50/60 Hz Resistance: 6,0 kΩ ± 800 Ω or 4,6 kΩ ± 800 Ω Depending on manufacturer Speed: 4-5 min-1 Technical specifications TC / USA: Nominal voltage: 120 V Power input: 5W Frequency: 50 / 60 Hz Resistance: 5,9 kΩ ± 800 Ω Or 4,7 kΩ ± 800 Ω 1. Disconnect plug X2 from power module and measure resistance on the wires for the water points motor, contact 3 and 4. Depending on manufacturer Speed: 5/6 min-1 If the resistance value is ∞, check wires for interruptions and measure directly on the water points motor. 155_58300000149128_ara_en_c – 12.02.13 Seite 92 von 181 5.10.2 Measuring water points motor (on the component) Requirement: ► Rinsing tank folded down. Measured values, see table. 5.10.3 Water points pulse transmitter The water points pulse transmitter cannot be tested. Measure the resisitance of the feed cable. If there is a fault on the pulse transmitter, the water points run continuously. There are no initialisation pulses. 155_58300000149128_ara_en_c – 12.02.13 Seite 93 von 181 5.11 Power cord 2 strong catch mechanisms on the sides prevent the plug from becoming loose or coming out of the appliance. 5.11.2 Removal Disconnect the power cord from the appliance by carefully moving it up and down (not sideways!!) and simultaneously pulling the appliance plug. 5.11.1 Installation 155_58300000149128_ara_en_c – 12.02.13 Seite 94 von 181 5.12 Replacing feed pipe 5.12.2 Installation Installation is in reverse sequence. 5.12.1 Removal 1. Tug the lower spray arm slightly and pull off the feed pipe. 2. Unscrew both Torx screws on the pump sump. 3. Loosen catch mechanisms in the area of the coupling point. 4. Carefully loosen top catch mechanisms on the roof sprinkler (optionally) using a small flat-blade screwdriver. 155_58300000149128_ara_en_c – 12.02.13 Seite 95 von 181 5.13 Removing the worktop 1. Remove two screws at rear. 2. Press up both locking levers under the worktop. 5.13.1 Removal 155_58300000149128_ara_en_c – 12.02.13 3. Lift the front of the worktop slightly. 4. Push back the worktop and lift off. Seite 96 von 181 5.13.2 Installation 1. Lock back of worktop into the guides with the retaining lugs. 2. Push forwards. 3. Press down front of worktop until both locking levers click into position. 4. Screw the two screws back in again. 155_58300000149128_ara_en_c – 12.02.13 Seite 97 von 181 5.14 Installing optional elements in the baskets Optional elements can be fitted in the baskets. 5.14.1 Tablet chute 86 cm model 614935 155_58300000149128_ara_en_c – 12.02.13 Seite 98 von 181 5.14.2 Cup support clip618565 Opening the clips: When washing cups, the cup support clip can be folded up. The additional inclined position reduces the accumulation of water on the underside of the cup. In the case of tall glasses it is recommended to fold down the cup support clip. If top baskets feature optional plastic inserts, these must be removed first. Engage cup support clips. 155_58300000149128_ara_en_c – 12.02.13 Seite 99 von 181 5.14.3 Gastronorm insert holder Positioning the utensils: 155_58300000149128_ara_en_c – 12.02.13 Seite 100 von 181 5.14.4 Setting up vario cutlery drawer plus – optional from 10/2011 on Press the lateral plastic inserts outward. Pull it upward from the framework. Only the disassembly of flexible elements of the vario cutlery drawer plus is shown. The assembly takes place in reverse order. Plastic parts are to be engaged evenly and examined for tightness. Remove handle: Bend latches inward. Remove handle upward. 155_58300000149128_ara_en_c – 12.02.13 Seite 101 von 181 Bend guide straps carefully outward. Pull flip tines from the laughter. 155_58300000149128_ara_en_c – 12.02.13 Press the metal frames from the mounting plates in front. Push to the rear from the guidance. Seite 102 von 181 5.15 Installing childproof lock Requirement: ► Worktop removed 155_58300000149128_ara_en_c – 12.02.13 Seite 103 von 181 5.16 Replacing / resetting door lock 5.16.2 Installation Requirement: √ Worktop removed or √ appliance pulled out as far as rinsing tank frame. 5.16.1 Removal 1. Insert the new door lock. 2. Bend in the two metal brackets again to secure the door lock. 5.16.3 Reset If the snap lock is locked manually (if required when using the transparent diagnosis door), the system must be released again. To do this, close the door firmly. 1. Straighten metal brackets on right and left of the door lock. 2. Lift off door lock. 155_58300000149128_ara_en_c – 12.02.13 A strong mechanical resistance must be overcome! Seite 104 von 181 5.17 Replacing side panels Requirement: √ Remove worktop (if fitted). 5.17.1 Removal 1. Loosen screws of the side panel on the front side. 2. Fold out the upper side of the side plate. 3. Push down the side panels and detach from the retaining lugs of the base pan. 155_58300000149128_ara_en_c – 12.02.13 Seite 105 von 181 5.17.2 Installation Installation 1. Attach the side panel to the catches of the appliance underside. 2. Press evenly onto the appliance. 3. Screw together side wall. 155_58300000149128_ara_en_c – 12.02.13 Seite 106 von 181 5.18 Removing outer door Panel screws ► It is not necessary to remove the topmost 6 screws in order to remove the outer door. ► Take hold of the sides of the outer door to prevent it falling down. 5.18.1 Removal Remove outer door by removing the 3 screws on each side of the inner door. 155_58300000149128_ara_en_c – 12.02.13 Seite 107 von 181 5.18.2 Installation Position insulating mats and force sensors. Close inner door but do not engage. 1. Push outer door with the upperside at an angle under the fascia. 2. Press outer door onto the inner door. With the door open slightly, screw together from inside. Panel screws ► Use 4x11 mm screws. 155_58300000149128_ara_en_c – 12.02.13 Seite 108 von 181 5.19 Variable hinge – installation, optional 5.19.1 Removal Requirement: base panel removed Note Installation height ► Before pulling the dish washer out of installation mark the installation hight. (e.g.: distance (a) between floor to lower edge of the dish washer). ► The equipment must be aligned in the same height before assembly the furniture front Example: 1. Pull appliance out of the installation cavity. 155_58300000149128_ara_en_c – 12.02.13 Seite 109 von 181 1. Remove 4 screws. 155_58300000149128_ara_en_c – 12.02.13 1. Remove both chrome strips. Seite 110 von 181 1. Loosen lock screws (3 ~ 5 rounds). 1. Raise furniture door and 2. push it upwards till the upper slide is out of the guide. 155_58300000149128_ara_en_c – 12.02.13 Seite 111 von 181 1. Remove 6 housing screws from the front door. 1. Remove screws. 155_58300000149128_ara_en_c – 12.02.13 Seite 112 von 181 1. Pull outer door slightly away from the appliance. 2. Carefully remove downwards. 155_58300000149128_ara_en_c – 12.02.13 1. Move hinge upside 2. Remove both slideelements from the conduct Seite 113 von 181 5.19.2 Installing outer door 1. Insert both slideelements to the conduct 2. Move hinge upside 1. Insert outer door from below into the inner door. 2. Press outer door towards the appliance. Position of the screws ► When reusing the sliding elements observe the correct screw position the structure (see chapter: Mounting furniture journal) ► Make sure that the upper and lower sliding elements slide in the metal outer door correctly 155_58300000149128_ara_en_c – 12.02.13 Seite 114 von 181 1. Mount the joint on the hinge side plate and screw in from below. Screws ► Use 4x11mm screws. Installation ► Make sure that the joint is properly inserted into the nose with the hinge. 1. Assemble outer door with 6 housing screws. 2. Screw from below 155_58300000149128_ara_en_c – 12.02.13 Seite 115 von 181 Dimensions for 86 cm models: 5.19.3 Installing furniture door When installing the door for the first time, attach the 4 retaining elements to the furniture door as described in the installation instructions. Dimensions for 81 cm models: 1. Mark installation points exactly with 2 mm drill bit attach 4 retaining elements exactly. 155_58300000149128_ara_en_c – 12.02.13 Seite 116 von 181 Incorrect marking and attachment! Destruction of the furniture door To ensure the the correct assembly height, the measures (b) and (c) must agree. Condition: Equipment correctly aligned ► The attachment points of the retaining element must be observed exactly. If the 4 retaining elements are attached unevenly or slanted, the furniture door may jam when it is being opened or closed. CAUTION ► The screw fittings of the hand grip must always be countersunk. The distance (b) from the upper edge of the neighbouring front to the clamping screw of the glider must correspond to the distance (c) from the upper edge of the furniture sheet up to the middle of the connection clip. Tolerance Countersink screw fittings of the hand grips. 155_58300000149128_ara_en_c – 12.02.13 ► Disagree the dimensions, connection clip must be adapted! the height of the Seite 117 von 181 Up to and including FD 9205 (Primary system) Check the locking screws. The guide part cannot be positioned securely unless the gap between the sliding elements is free. The screws must be unscrewed far enough. Incorrect position of the locking screws! Destruction of the retaining elements or the sliding elements on the articulated joints. CAUTION ► The locking screws must be unscrewed a long way before the furniture door can be attached. The receiving gap in the sliding elements must be free to prevent the retention lugs from catching or being blocked. 1 Guide part 2 Slider The guide part has to be positioned in such a way in the sliding elements, that the locking screw is in the centric recess. 155_58300000149128_ara_en_c – 12.02.13 Seite 118 von 181 From FD 9205 on For all FD: (Modified system) 1. Insert sliding elements correctly into the guides. 2. Press furniture door onto the outer door. Carefully lower furniture door as far as the stop. The screw must be screwed in, but not fixed. 155_58300000149128_ara_en_c – 12.02.13 Seite 119 von 181 Mounting by using screws ► The long screws, which are used in solid furnitures, are not required anymore! The mobile system can be damaged by fixing the furniture sheet. VORSICHT 1. Position decorative strips. 1. Align furniture door. 2. Screw on decorative strips. 2. Tighten 2 locking screws by hand. 155_58300000149128_ara_en_c – 12.02.13 Seite 120 von 181 1. Install appliance and 2. install base panel. 155_58300000149128_ara_en_c – 12.02.13 Seite 121 von 181 5.20 Replacing the dispenser Requirement: ► Outer door or décor panel removed. Sharp-edged sheet-metal parts! Risk of injury 5.20.1 Removing the dispenser 1. Take cable duct out of the catches. 2. Loosen plug-and-socket connection. 155_58300000149128_ara_en_c – 12.02.13 ► Wear protective gloves. CAUTION 5.20.2 Removal 1. Carefully bend sheet-metal brackets away from the dispenser and press dispenser carefully inwards and ensure that it does not fall into the appliance. Seite 122 von 181 5.20.3 Installation ► Before installing the dispenser, bend back sheet-metal brackets to the initial position. 1. Install cable guide. 2. Re-attach plug-and-socket connection. 1. Engage dispenser evenly in the door and ensure that all 8 catch mechanisms have engaged. 155_58300000149128_ara_en_c – 12.02.13 Seite 123 von 181 5.21 Installing the detergent cover 1. Attach long end of spring to the dispenser. 2. Attach short end of spring to the detergent cover. 3. Press cover into the dispenser. 155_58300000149128_ara_en_c – 12.02.13 Seite 124 von 181 5.21.1 Replacing EmotionLight (optionally) Requirement: √ Worktop (optional) removed √ Side panel on right removed 5.21.2 Removal 1. Take Hall sensor out of the rinsing tank. 1. Remove both LEDs 2. with holder from the rinsing tank. 1. Loosen plug-and-socket connection. (Carefully expose ribbon cable.) 155_58300000149128_ara_en_c – 12.02.13 Seite 125 von 181 5.21.3 Installation 1. Re-attach plug-and-socket connection. (Carefully lay ribbon cable behind the hinge plate.) 1. Insert LEDs and Hall sensor into the frame of the rinsing tank. 155_58300000149128_ara_en_c – 12.02.13 Seite 126 von 181 5.22 Replacing infolight Infolight If the Infolight must be exchanged, be examined damming mat and cable run and adapted if necessary In case of a defect the Infolight is to be renewed completely. With the installation the cutout of the damming mat and the cable run are to be examined. If the damming mat still is in the form such as illustration 1, this 15mm is to be cut out further, sees illustration 2. This is valid only for fully integrated devices without Piezooperation. Illustration 1: Cut out damming mat to FD 8810 and devices with Piezooperation Squeeze noses carefully together. Remove Infolight to the door center. Illustration 2: Cut out damming mat from FD 8811on 155_58300000149128_ara_en_c – 12.02.13 Seite 127 von 181 5.23 Replacing TimeLight Bend the latches (1) back before installation. Push the TimeLight module back into the guidance (2). In case of a defect the Infolight is to be renewed completely. To disassembly bend the latches (1) easily outward. Pull the TimeLight module upward from the guidance (2). 155_58300000149128_ara_en_c – 12.02.13 Seite 128 von 181 5.24 Replacing the fascia √ Outer door (if fitted) removed. Note ► When loosening the last screw, hold the fascia with one hand. It is no longer secure and may fall down. ► Use 4x16 mm screws. 5.24.1 Preparation: 1. Remove wires on left and right from the bushings. 2. Remove wire from rinse-aid sensor. 3. Remove earth wire if fitted. 155_58300000149128_ara_en_c – 12.02.13 Seite 129 von 181 5.24.2 Removal Open door. Loosen upper 6 screws. Remove fascia. 5.24.3 Installation 1. Fix fascia to the inner door and then screw in the 6 screws. 2. Re-attach plug-and-socket connections. 155_58300000149128_ara_en_c – 12.02.13 Seite 130 von 181 5.25 Replacing the door springs √ Corresponding side panel removed. Different spring systems ► Two different spring systems are used. Both of them are described in this chapter. 5.25.1 Removal (Spring system I) 1. Open door slightly. 2. Grip tension cord with flat-nosed pliers. 3. Close door. 1. Remove cord guide cover outwards. 155_58300000149128_ara_en_c – 12.02.13 Seite 131 von 181 5.25.2 Table of springs (spring system I): Version: Max. Remove cord system with spring (1), cord (2), deflection lever (3) and holder (4) forwards. . Min. Height: Colour: Mat.-Nr: Weihgts of furniture door: Fully integrated 86,5 cm (39dB) Light Blue 623843 3,0 Kg to 10 Kg Fully integrated 86,5 cm Pink 611340 3,0 Kg to 10 Kg Integrated 86,5 cm Green 611339 2,5 Kg to 8,5 Kg Fully integrated 81,5 cm Black 611338 2,5 Kg to 8,5 Kg Integrated 81,5 cm Blue 611337 2,5 Kg to 8,5 Kg Free standing; Build under 86,5cm+ 81,5 cm stainless steel Red 611336 ------- Free standing; Build under 81,5 cm Yellow 611335 ------- ► The door springs can be identified by a coloured dot on the rear of the appliance. ► The door springs must be replaced in pairs only! ► Do not install different springs! ► The same colour coding must be used on the right and left! 155_58300000149128_ara_en_c – 12.02.13 Seite 132 von 181 5.25.3 Assembling Tension cord holder ► The tension cord holder must be attached as illustrated in order to prevent friction on the base pan. Insert tension cord to the spring (1) and fix it in the notch of the base pan (2). 1. Fix tension cord holder in the notch of the base pan. The cord system is automatically attached to the door lever. 155_58300000149128_ara_en_c – 12.02.13 Seite 133 von 181 5.25.4 Removal (Spring sytem II) See Removal Spring System I ► The door springs can be identified by a coloured dot on the rear of the appliance. 5.25.5 Table of springs (Spring system II) ► The door springs must be replaced in pairs only! Max. Min. Table of springs ► Do not install different springs! ► Do not use springs of 45 cm models. ► The same colour coding must be used on the right and left! Version: Height: Colour: Fully Integrated 86,5 cm (39dB) Light blue 659341 3,0 Kg to 10 Kg Fully Integrated 86,5 cm Pink 626664 3,0 Kg to 10 Kg Integrated 86,5 cm Green 659340 2,5 Kg to 8,5 Kg Fully Integrated 81,5cm Black 626662 2,5 Kg to 8,5 Kg Integrated 81,5 cm Blue 626665 2,5 Kg to 8,5 Kg Free standing; Build under 86,5 cm + 81,5 cm Stainless steel Red 659339 ------- Free standing; Build under 81,5 cm Yellow 155_58300000149128_ara_en_c – 12.02.13 Mat.-Nr: 626667 Weihgts of furniture door: ------- 5.25.6 Installing door spring 1 Spring 2 Notch Install cord system in reverse order. Fix the spring in the providet holder of the base pan. If spring is broken (1) or tension cord is torn and if it is suspected in general that the plastic holder (2) sprayed on the container is damaged: ► Attach new spring with the metal retaining plate enclosed with the spare part! Seite 134 von 181 1 Metal retaining plate 2 Spring Attach metal retaining plate to spring. Noises When converting or replacing the spring, ensure in particular that the front plastic holder is correctly repositioned; otherwise it may cause noises on the side panel. 1 Metal retaining plate Hammer metal retaining plate into designated groove in base group. ► Place plastic holder correctly in the base group. 155_58300000149128_ara_en_c – 12.02.13 Seite 135 von 181 155_58300000149128_ara_en_c – 12.02.13 Seite 136 von 181 5.26 Replacing heat exchanger Requirement: ► Left side panel removed ► Heat exchanger emptied 5.26.1 Removal of heat exchanger 1 Markierung 1. Mark the installation position of the expansion opening nut and remove expansion opening nut. 2. Remove cover cap (optional). 3. Remove waterinlet connection. 1 Expansions opening-nut 2 Cover, water inlet 155_58300000149128_ara_en_c – 12.02.13 3 Waterinlet connection Seite 137 von 181 1. Remove both Torx screws on the outside of the tank. 2. Bend out the guard cover of the impeller wheel counter and remove plug connection. 3. Remove plug connection on the drainage valve. 4. Loosen hose clamp on the water supply and remove supply hose. 5. Loosen catch mechanisms on the front of the housing. 6. Carefully pull heat exchanger forwards. In doing so, detach from the holder on the rear of the appliance and remove. After prolonged operation the heat exchanger may become stuck to the bitumen insulation and be difficult to remove. 1 Container fitting 4 Water supply hose with clamp 2 Impeller wheel counter with cover 5 Catch mechanism 3 Drainage valve 6 Holder 155_58300000149128_ara_en_c – 12.02.13 Seite 138 von 181 5.26.2 Mounting heat exchanger Assembly sequence ► The assembly sequence described here is to be kept. Leakage ► Pay attention to the correct position of the sealing in the expansion opening. Prevent leakage ► Avoid squeezings of the connections to the Water softener and water drain hoses 1. Insert the heat exchanger to the connections of water softener and drain hoses. 2. Slip water inlet hose to heat exchanger and fix it with the clamp. 3. Press the heat exchanger to the container. 4. Lock the heat exchanger on the container. 1. Tighten the expansion opening nut to the marking. 2. To prevent leakage, around the value + 3 hours (1/4 revolution) continue to tighten. 3. Mount and tighten waterinlet connection. 4. Push cover cap (optionally) to water inlet connection. 5. Fix the heat exchanger with screws from outside to the container. 6. Connect the wheel counter and the drainage valve with the electrical plugs. 155_58300000149128_ara_en_c – 12.02.13 Seite 139 von 181 5.27 Replacing flow sensor Requirement: ► Side panel on left removed Risk of breakage ► Do not bend or kink boards with a flow sensor in the flask! ► Component is very sensitive! Carefully bend out the plastic flap on the heat exchanger / water inlet. Loosen plug-and-socket connection 1. Take complete board with flow sensor out of the catch mechanisms. 2. Unpack new flow sensor, take board out of transportation safety device and dispose of holder. 3. Carefully attach new board to the heat exchanger / water inlet. Reconnect power supply and bend back plastic flap. 155_58300000149128_ara_en_c – 12.02.13 Seite 140 von 181 5.28 Replacing drainage valve 1. Remove the drainage valve by rotating it in a clockwise direction. 2. Pull out of the heat exchanger. Drainage valve ► If the valve has to be replaced, drain or catch water. ► It is not necessary to remove the drainage valve in order to remove the heat exchanger! 155_58300000149128_ara_en_c – 12.02.13 Seite 141 von 181 5.29 Replacing the regeneration valve 5.29.2 Remove anchor Requirement: √ Side panel on left removed. √ Optionally: Heat exchanger emptied. √ Water drained from the salt dispenser. 5.29.1 Removal 1. Insert a small screwdriver in the valve position 2. Lever the valve insert carefully loosely 3. Remove the valve insert from the regeneration unit Install in reverse sequence. 1. Rotate valve anti-clockwise. 2. Pull out valve forwards. 155_58300000149128_ara_en_c – 12.02.13 Seite 142 von 181 5.29.3 Positioning the armature 1. Align the marked points. 2. Press valve with spring back into the coil until the valve engages. 155_58300000149128_ara_en_c – 12.02.13 Seite 143 von 181 5.30 Replacing the drainage hose Requirement: √ Left side panel removed. 5.30.1 Removal 1. Loosen the panel catch mechanism. 2. Fold out the panel. 1. Press drainage hose backwards out of the holder. 2. Remove downwards from the heat exchanger / water inlet. 5.30.2 Installation Is in reverse sequence. 155_58300000149128_ara_en_c – 12.02.13 Seite 144 von 181 5.31 Replacing the supply hose Requirement: √ Left side panel removed. 5.31.1 Removal 1. Loosen the panel catch mechanism. 1. Remove electrical connection. 2. Flap to the right hand side. 3. Fold out the panel. 155_58300000149128_ara_en_c – 12.02.13 Seite 145 von 181 1. Open clamp. 2. Remove supply hose from the heat exchanger / water inlet. 5.31.2 Installation Is in reverse sequence. 155_58300000149128_ara_en_c – 12.02.13 Seite 146 von 181 5.32 Replacing the power module Requirement: ► Right side panel removed. ► Optional liquor reservoir removed. ► Power cord removed from the appliance. 5.32.1 Removal 1. Loosen catches and 2. lift off module. 1. Using a screwdriver, carefully lever the cap to the left and loosen the catch. 2. Lift off cap upper section. 155_58300000149128_ara_en_c – 12.02.13 Seite 147 von 181 5.32.2 Remove cap 5.32.3 Open the power module 1. Loosen the catching by an easy hitch. 2. Remove the cap. 1. Loosen housing catches all around. 2. Pull housing parts apart. 155_58300000149128_ara_en_c – 12.02.13 Seite 148 von 181 5.32.4 Loosen cable harness Coding frames ► The coding frames are to be opened only if necessary. They are a component of the wiring harness and remain not on the module. Components which come into contact with electrostatic voltage will be damaged beyond repair 1. Loosen catch and 2. Lift off complete coding frame with plugs. ► Before carrying out any work, apply protective system to components susceptible to electrical discharge. ► Observe measures to protect the components suscep-tible to electrical discharge. 155_58300000149128_ara_en_c – 12.02.13 Seite 149 von 181 5.32.5 Installation Installation is in reverse sequence. The power module must engage audibly into the base pan. Re-attach the splash guard cover. 1. Insert coding frame into the guide. 2. Press down until the catch clicks into position. Plugs ► Respect for tighten the plug within the coding frame. Laying of cables ► Cables must always be installed under the cap section with water outlet channel.. 155_58300000149128_ara_en_c – 12.02.13 Seite 150 von 181 5.33 Replacing base panel and plate 5.33.1 Removal Incorrect removal ► If the base panel is slackened at the side and removed, the two holders may break off. If only one holder is damaged, the side can be changed, as both holders are the same. ► It is recommended to place your feet under the front of the appliance to relieve the load on the base panel. 155_58300000149128_ara_en_c – 12.02.13 Seite 151 von 181 1. Loosen base plate by unscrewing the Torx screws. 2. Lever the plate out of the catches and remove. The underside of the base panel is secured with 2 catches. 1. Insert a screwdriver into the guides (1) and remove the catch mechanism downwards. 2. Remove panel upwards. 155_58300000149128_ara_en_c – 12.02.13 Seite 152 von 181 5.33.2 Installation 1. Put base panel on top. 1. Place base plate in the catches. 2. Press down until it clicks into position. 2. Press up and screw together. 155_58300000149128_ara_en_c – 12.02.13 Seite 153 von 181 5.34 Replacing non-return valve 5.34.1 Removal Requirement: ► Outer door removed ► Base panel and plate removed ► Water removed from pump sump ► Drainage hose removed from pump sump Scratches ► During removal, do not scratch the inside of the outlet connection with a sharp-edged screwdriver. Leaks may occur. 155_58300000149128_ara_en_c – 12.02.13 Seite 154 von 181 5.34.2 Installation 155_58300000149128_ara_en_c – 12.02.13 Seite 155 von 181 5.35 Replacing the Aquasensor Requirement: ► Base panel and base plate removed. 5.35.2 Installation Insert and lock board. 1. Press Aquasensor with board edgewise into the pump sump. 2. Rotate 90° to the right and lock in position. 5.35.1 Removal 1. Loosen catch mechanism. Seal ► To facilitate rotating the Aquasensor, the seal can be lubricated with Promol or rinse aid. 2. Rotate Aquasensor housing by 90° to the left. 3. Pull out forwards. 155_58300000149128_ara_en_c – 12.02.13 Seite 156 von 181 5.36 Folding down rinsing tank 5.36.2 Removing overflow channel The rinsing tank must be folded down all the way from the base pan for the following work: ► Replacement of the water softening system. ► Replacement of the pump sump. ► Replacement of the heating pump. ► Replacement of the water points. 5.36.1 Requirements Remove overflow channel Remove drainage hose Remove float switch safety system Open supply hose grommet Remove power module Remove filling hose of water storage tank (optionally) 1. Detach from the upper catch mechanism. Disconnect actuator of water storage tank (optionally) 2. Take out of the lower guide. Disconnect emotion light (optionally) 155_58300000149128_ara_en_c – 12.02.13 Seite 157 von 181 5.36.3 Removing drainage hose 5.36.4 Removing float switch safety system Residual water ► When the drainage hose is removed, residual water may run out. Catch water or remove from the base pan with suction syringe. 1. Loosen catches. 2. Remove switch upwards. 1. Press flexible drainage hose upwards out of the fixing. 2. Remove from pump sump. 155_58300000149128_ara_en_c – 12.02.13 Seite 158 von 181 5.36.5 Opening supply hose grommet (aquasop models) 5.36.6 Opening supply hose grommet (water inlet valve models) 1. Loosen the panel catch mechanism. 2. Fold out the panel. 3. Press the hose bushing at a slight angle into the base pan to have more clearance to fold down and remove the rinsing tank. 1. Loosen locking lever. 2. Fold the cover with the inlet hose outward. 3. Remove supply hose. 155_58300000149128_ara_en_c – 12.02.13 Seite 159 von 181 5.36.7 Loosening the tank catch mechanism The rinsing tank is held and locked at the front and rear in guides on the base. The rinsing tank is fixed at the rear on the left and right with sheetmetal brackets. These are bent by a plastic lug on the base pan. 1. Using a screwdriver, detach hinge plates at the front side from the top of the catch mechanism. To do this, bend in the hinge plate catch mechanism. 1. Using a screwdriver, straighten sheet-metal brackets. 155_58300000149128_ara_en_c – 12.02.13 Seite 160 von 181 5.36.8 Folding down the rinsing tank Close salt dispenser ► Always check that the salt dispenser cover is screwed shut to prevent salt solution from running out subsequently when the tank is folded down! ► Protect support surface for the rinsing tank from being scratched. ► Tank is seated firmly in the guides and requires only a little force to lift it out. To facilitate handling, the appliance can be placed on its back and the base pan carefully removed. ► In the case of free-standing appliances, ensure that the weight does not fall out of the base pan. 1. Carefully lift rinsing tank upwards. 2. Place rinsing tank towards the rear. 155_58300000149128_ara_en_c – 12.02.13 Seite 161 von 181 ► If the appliance is on its back and the base pan is removed, ensure that the weight does not fall out of free-standing appliances. 5.36.9 Components on the tank In this state the following components/modules which are attached to the tank can be replaced: 1. Cable harness 2. Heating pump 3. Power module (not fixed to the tank) 4. Water points with motor and pulse transmitter - optionally 5. Water softening system 6. Pump sump 155_58300000149128_ara_en_c – 12.02.13 Seite 162 von 181 5.37 Replacing pump sump Requirement: √ Rinsing tank folded down √ Heating pump removed √ Water points removed √ Drain pump removed √ Supply pipe removed 5.37.1 Removal Risk of injury! Sharp-edged sheet-metal parts ► The edge of the sheet metal at the opening for the pump sump may be sharp-edged! ► Wear gloves. 155_58300000149128_ara_en_c – 12.02.13 Loosen 4 screws (1. to 4.) in the interior container and remove pump sump downwards. Seite 163 von 181 5.37.2 Installation Sequence of screw connections ► Always observe the sequence of the screw connections. Leaks may occur. Ensure that the seal is correctly positioned! Brush with a little Promol or rinse aid. Place pump sump from below directly and without tilting it on the container. Insert and tighten screws in reverse sequence: 1. at rear right 2. at rear left 3. at front left 4. at front right 155_58300000149128_ara_en_c – 12.02.13 Seite 164 von 181 5.38 Replacing heating pump 5.38.1 Removing heating pump Requirement: Rinsing tank folded down Do not open heating pump. ► The heating pump can be replaced as a whole component only. Individual parts are not available. 1. Using side cutters, loosen the hose clamp on the water points connection. 1. Detach rubber holder from between pump unit and pump sump. 155_58300000149128_ara_en_c – 12.02.13 Seite 165 von 181 5.38.2 Installing the heating pump 1. Carefully remove/rotate heating pump off the water points hose. 2. By gently rotating the heating pump, pull it backwards. Moisten inside of rubber seal with rinse aid. 1. Push heating pump onto the pump sump and 2. press outlet channel into the water points. 155_58300000149128_ara_en_c – 12.02.13 Seite 166 von 181 Drain pump seal ► The replaced seal for the intake channel must be inserted all the way into the housing of the heating pump. 5.38.3 Cleaning the heating pump The heating pump must be cleaned from the outside only. If the heating pump is opened, the leak tightness can no longer be guaranteed when the heating pump is closed again. Tighten the hose clamp as illustrated. ► Hose clamp mat. no.: 172272 is required for the re-installation. ► The hose clamp is supplied with the spare parts water points, pump sump and heating pump (set). 155_58300000149128_ara_en_c – 12.02.13 Seite 167 von 181 5.39 Replacing water points Requirement: √ Rinsing tank folded down √ Circulation pump removed 5.39.1 Removal Loosen the water points ► The water points housing requires effort to turn! ► Wear gloves. 1. Remove the hose for water storage tank (optionally) 2. Loosen catch mechanism. 3. Rotate water points counter clockwise. 155_58300000149128_ara_en_c – 12.02.13 Seite 168 von 181 5.39.2 Installation Brush rubber seal with a little Promol or rinse aid. 1. Position Z–shaped piece of the water points between the two bars of the pump sump. 2. Press water points flat on the pump sump. 3. Lock in position by rotating in a clockwise direction. 4. Fix the hose from water storage tank again (optionally) 155_58300000149128_ara_en_c – 12.02.13 Seite 169 von 181 5.40 Replacing water softening system 5.40.1 Removal Requirement: √ Rinsing tank folded down. Risk of injury! Sharp-edged sheet parts ► The edge of the sheet at the opening for the water softening system may be sharp! CAUTION AU-models Conditional from manufacturing, Australia models have partially a "dummy" – water softener without softening pellets. The valve is replaced by a blind plug. It is important to ensure that the lid is always screwed to the water softener. 1. Loosen plug-and-socket connection on the regeneration valve. 155_58300000149128_ara_en_c – 12.02.13 Seite 170 von 181 2. 1. Salt dispenser cover removed. 2. Loosen salt dispenser nut with special tool mat. no.: 341805. Remove water softening system downwards. 155_58300000149128_ara_en_c – 12.02.13 5.40.2 Installation Push water softening system from below into the rinsing tank. 1. Tighten salt dispenser nut with special tool mat. no.: 341313. 2. Screw on cover. Seite 171 von 181 5.41 Replacing the drain pump Requirement: √ Base panel and plate removed. √ Water drained. 5.41.1 Removal 1. Remove plug. 2. Pull catch mechanism lever (1) for the drain pump forwards. 3. Rotate drain pump clockwise. 4. Remove pump forwards out of the pump sump. 5.41.2 Installation ► Proceed in reverse sequence. 155_58300000149128_ara_en_c – 12.02.13 Seite 172 von 181 5.42 Counterweight 5.42.2 Installation √ Rinsing tank folded down 5.42.1 Removal 1. Check rubber damper is in correct position. 1. Remove the weight upwards. 155_58300000149128_ara_en_c – 12.02.13 2. Insert weight into the recesses. Seite 173 von 181 5.43 Attaching the rinsing tank 5.43.1 Attaching the rinsing tank Ensure it is seated correctly ► Ensure that the weight is installed correctly in freestanding appliances. ► If the heat exchanger is mounted on the rinsing tank, ensure that the hose connections are clean. ► Do not trap supply and drainage hoses. ► Push water softening system into the guides. ► Protect power module from jamming. ► Protect cable harness from crushing. 1. Carefully fold the rinsing tank forwards. 2. Insert into the guides. 155_58300000149128_ara_en_c – 12.02.13 Seite 174 von 181 5.43.2 Protecting tank catch mechanisms 1. Ensure that the connection is faultless without crushing the terminals on the heat exchanger. 155_58300000149128_ara_en_c – 12.02.13 1. Using a screwdriver, bend hinge plate catch mechanism outwards. Seite 175 von 181 5.43.3 1. Using a screwdriver, bend over sheet-metal brackets. Installing the supply hose Take the hose bushing out of the base pan. 1. Insert panel. 2. Lock panel. 155_58300000149128_ara_en_c – 12.02.13 Seite 176 von 181 5.43.4 Installing float switch safety system 1. Press float switch into the catch mechanism of the base plate. 5.43.5 Installing the drainage hose 1. Push drainage hose into the pump sump. 2. Press flexible drainage hose into the fixing. Insert power module and fix it. Visual inspection . ► Finally a visual check is on possibly gotten jammed or wrongly engaged construction units to accomplish cables or hoses ► Connect emotionlight and check. 155_58300000149128_ara_en_c – 12.02.13 Seite 177 von 181 5.44 Transparent door Permanent magnet ► If using the transparent door, a permanent magnet must be positioned in the inside door. It is used to signal “door closed” to the door contact switch. The door contact switch responds to the direction of the magnetic field. ► If required, turn the permanent magnet until the appliance detects the magnetic field correctly. ► If the snap lock is locked manually, the system must be released again. To do this, close the door firmly 1. Open appliance door. 2. Place transparent door in the appliance and engage at the top in the door lock. Order numbers: 1. Attach suction button with magnet to the upper edge of the inner door. Transparent door 81 cm: 341333 Transparent door 86 cm: 341334 Magnet: 341332 155_58300000149128_ara_en_c – 12.02.13 Seite 178 von 181 5.45 Loading appliance software 5.45.1 UDA connection to the operating module in the door Requirement: √ UDA with cable and adapters √ Computer √ I-Service software DANGER Exposed live parts Danger to life caused by electric shock! ► Disconnect the appliance from the power supply. ► Do not touch housing, frame or components. ► Use residual-current-operated circuit-breaker if tests have to be conducted with the power on. ► Ensure that the resistance of the protective conductor does not exceed the standardised values. Disconnect the appliance from the power supply. 1. Connect Y-cable to the operating module. 2. Connect to UDA. Reconnect appliance to the power supply. CAUTION Voltage peaks when disconnecting/connecting the plugin contacts The operating module or the Piezo power supply unit (optional) will be destroyed by the mains potential on the earth cable of the bus system. ► Disconnect the appliance from the power supply before disconnecting/connecting plug-in connections. ► Do not connect Y cable to the power module. 155_58300000149128_ara_en_c – 12.02.13 Seite 179 von 181 5.45.2 UDA connection to the power module 5.45.3 Software The UDA connection cable can also be connected directly to the power module. The Y-cable must not be used for this connection. Open iService Software on the computer and load appliance software. When flashing is complete, switch off the appliance and disconnect from the power supply (reset mains) After the main reset, a software / programm reset must be done in any case. Insert UDA connection cable into the free i-Service/D-Bus² connection. If both slots are occupied, unplug the lower plug and use this slot. The function of the operating module is then retained. 155_58300000149128_ara_en_c – 12.02.13 Seite 180 von 181 5.46 Technical specifications Power consumption in stand by: Operating panel with push buttons: < 0,1 W Operating panel with Piezoelectronic: < 0,8 W Time delay mode, cycle end mode & left open mode Max. 2,5 W Main power voltage range: EU, CH, GB, BS, TH, AU UC BR, MX JP TC 220-240V 50/60 Hz 120V 127V 200V 110V 60 Hz 60 Hz 50/60Hz 60 Hz 155_58300000149128_ara_en_c – 12.02.13 Seite 181 von 181