Preview only show first 10 pages with watermark. For full document please download

1. Technical Specifications 2. General Specifications

   EMBED


Share

Transcript

HT300 Rel. 1.02 of 14/07/10 Hand held digital thermometer with type K/J probes 1. TECHNICAL SPECIFICATIONS Accuracy is given as ± [% of reading + values] at 23°C ± 5°C, <80%RH TEMPERATURE WITH TYPE K PROBE Range -200 ÷ 1370°C -328 ÷ 2498°F Resolution 0.1°C 0.1°F Accuracy (*) ±(0.05% rdg + 0.7 °C) ±(0.05% rdg + 1.4 °F) Overload Protection 24 V AC/DC RMS (*) Accuracy is referred to the meter only without external probes TEMPERATURE WITH TYPE J PROBE Range -200 ÷ 1050°C -328 ÷ 1922°F Resolution 0.1°C 0.1°F Accuracy (*) ±(0.05% rdg + 0.7 °C) ±(0.05% rdg + 1.4 °F) Overload Protection 24 V AC/DC RMS (*) Accuracy is referred to the meter only without external probes 2. GENERAL SPECIFICATIONS    Mechanical characteristics Dimensions of instrument (LxWxH): Weight of instrument (including battery): 130 x 56 x 38mm 170g Supply Battery type: Low battery indication: Battery life: Auto power OFF: 1 battery 9V NEDA 1604 IEC 6F22 JIS 006P. “ ” symbol is displayed approx 200 hours about 15 minutes of idleness Display Characteristics: 5 LCD double display with sign and decimal point Climatic conditions Reference temperature: Operating temperature: Operating humidity: Storage temperature: Storage humidity: Max height of use: 25°C ± 5°C 5 ÷ 40 °C <80%RH -10 ÷ 60 °C <70%RH 2000m This product conforms to the prescriptions of the EMC directive 2004/108/EEC HT ITALIA srl Via della Boaria 40 - 48018 Faenza (RA)- Italy Tel: +39-0546-621002 - Fax: +39-0546-621144 email: [email protected] - web: http://www.htitalia.com Page 1 of 2