TO: All Contractors FROM: LePique & Orne Architects, Inc. DATE: July 24, 2017 RE: New Base Station No. 18 ADDENDUM No. 6 Base 18 The following Addendum to the Drawings and Specifications modifies and supersedes previously issued documents. Acknowledge receipt of this Addendum on the Bid Form. IMPORTANT: This addendum and all bidding construction documents represent a comprehensive scope of work. It is each contractor’s responsibility to reference all drawings, specifications and addendums to verify their respective scope of work. General information and Specifications: 1. Supplementary Conditions, Paragraph 27: B) Clarification, Use this section for temporary fence & gates. A chain link fence will not be required on this project. Plumbing & Architectural Drawings: 1. Clarification: The exterior drain tile as shown that is to be routed to daylight shall be connected to the interior drain tile and ran to the sump pit, for the purpose of this bid. Electric Drawings: The attached electric drawings show the added circuit and wiring for the grinder pump, no other changes, please note the correct sheet attached. 1. End of Addendum No. 6 701 N. Fifth Street ■ Saint Charles, MO 63301 ■ (636) 947 -0099 ■ Fax (636) 947 -8700 GENERAL NOTES - ELECTRICAL 2 A. COORDINATE ELECTRIC UTILITY WORK WITH UTILITY ENGINEER PRIOR TO START OF CONSTRUCTION. B. REFER TO RISER DIAGRAM DETAIL 5/E0.1 FOR ADDITIONAL INFORMATION. # PLAN NOTES - ELECTRICAL 1. PROPOSED LOCATION OF NEW UTILITY PAD-MOUNTED TRANSFORMER. 2. PROVIDE ONE (1) 4" CONDUIT FROM EXISTING UTILITY COMPANY POWER POLE TO NEW UTILITY PAD-MOUNTED TRANSFORMER. VERIFY ALL REQUIREMENTS WITH LOCAL UTILITY COMPANY AND INSTALL PER THEIR REQUIREMENTS. COORDINATE CONDUIT ROUTING WITH OTHER UNDERGROUND UTILITIES. 3. PROVIDE ONE (1) 2" CONDUIT FOR TELEPHONE SERVICE AND ONE (1) 1" CONDUIT FOR CABLE TV. COORDINATE ROUTING WITH OTHER UNDERGROUND UTILITIES. 4. 48 kW EMERGENCY GENERATOR. 5. FLAGPOLE LIGHT FIXTURE, VERIFY FINAL LOCATION WITH OWNER. 6. PROVIDE 1" CONDUIT MINIMUM FOR SITE LIGHTING. 7. GRINDER PUMP, CONNECT PUMP AND COMBINATION AUDIBLE / VISUAL ALARM PER EQUIPMENT SUPPLIER SPECIFICATIONS COMPLETE AND READY FOR OPERATION. T 3 1 LPA-13 (VIA "SLC") #10 4 2 "SE" 4 13 1 5 "SC" 6 2 LPA-3 (VIA "SLC") 2 3 #10 (TYP.) "SF" 3 #10 13 GENERAL NOTES - MECHANICAL 4 A. COORDINATE NEW LOW PRESSURE GAS METER PER THE LOCAL UTILITY COMPANY, MECHANICAL CONTRACTOR AND AUTHORITY HAVING JURISDICTION REQUIREMENTS. CONFIRM GAS SYSTEM REQUIREMENTS WITH THE LOCAL UTILITY COMPANY. B. GAS COMPANY IS RESPONSIBLE FOR THE METER AND GAS LINES UP TO METER. CONTRACTOR IS RESPONSIBLE FOR ALL GAS EQUIPMENT AFTER THE METER. C. GAS LINE SHOWN IS FOR REFERENCE ONLY. COORDINATE EXACT LOCATION WITH GAS COMPANY. # PLAN NOTES - MECHANICAL 1. GAS MAIN EXTENSION BY LACLEDE GAS COMPANY UP TO THE GAS METER AT THE BUILDING. 2. PROVIDE LOW PRESSURE GAS METER PER THE LOCAL UTILITY COMPANY AND AUTHORITY HAVING JURISDICTION REQUIREMENTS. PROPOSED LOAD TO BUILDING: 1,200 CFH PROPOSED DELIVERY PRESSURE: 10"-14" W.G. COORDINATE GAS SYSTEM REQUIREMENTS WITH THE LOCAL UTILITY COMPANY. PROVIDE ALL PIPING, VALVES, ASSOCIATED MATERIALS AND PRESSURE REDUCING VALVES AS REQUIRED TO PROVIDE THE PROPOSED DELIVERY PRESSURE TO THE BUILDING. PAINT ALL GAS PIPING, VALVES AND MATERIALS EXPOSED TO THE ELEMENTS WITH RUST INHIBITING PAINT TO MATCH THE COLOR OF THE BUILDING EXTERIOR. VERIFY COLOR WITH ARCHITECT PRIOR TO PAINTING. VERIFY AVAILABLE GAS SERVICE DELIVERY PRESSURE WITH UTILITY COMPANY PRIOR TO BID. 3. 3/4" GAS TO SERVE GAS GRILL ON PATIO. COORDINATE FINAL LOCATION WITH OWNER. 4. 1" GAS TO SERVE GENERATOR, COORDINATE ROUTING IN FIELD. 5 #10 3 3 2 LP-37 J 13 "SE" #10 13 "SE" F 7 "SF" 13 "SF" 13 GENERAL NOTES - PLUMBING 1 N SITE PLAN - MEP SCALE: 1/16" = 1'-0" A. PRIOR TO CONSTRUCTION OF OR CONNECTION TO ANY STORM DRAIN, SANITARY SEWER, WATER MAIN, OR ANY OTHER UTILITIES, THE CONTRACTOR SHALL EXCAVATE, VERIFY AND CALCULATE ALL POINTS OF CONNECTION AND ALL UTILITY CROSSING AND INFORM THE OWNER/DEVELOPER OF ANY CONFLICT OR REQUIRED DEVATIONS FROM THE PLAN. # PLAN NOTES - PLUMBING 1. 1-1/2" WATER SERVICE. 2. 4" FIRE SERVICE, SEE CIVIL DRAWINGS FOR CONTINUATION. 3. PROVIDE OIL / SAND INTERCEPTOR, INSTALL PER MANUFACTURER'S INSTRUCTIONS. ROUTE (2) TWO 3" VENTS FROM INTERCEPTOR, SEE P2.0 FOR ADDITIONAL INFORMATION. 4. PROPOSED FIRE DEPARTMENT SIAMESE CONNECTION. 5. PROPOSED WATER METER LOCATION. 06-21-2017 PLAN MARK MOUNTING MANUFACTURER A W/S METALUX B C/R HALO C C/S METALUX GROUNDING BUS LOCATED IN MAIN PANEL TO BUILDING STEEL. TYPE "VS" EXOTHERMIC WELD. #1/0 #1/0 TYPE "GR" EXOTHERMIC WELD. PANELBOARD SCHEDULE LIGHTING FIXTURE SCHEDULE TO MAIN WATER PIPE. CONNECT AHEAD OF MAIN SHUT OFF VALVE. TYPE "VN" EXOTHERMIC WELD OR LISTED GROUND CLAMP. #6 UFER 2000 120 23 WHITE POLES: 2PSN SLD606830WHUNVJB 760 120 13 WHITE FEEDER: SEE RISER DIAGRAM 4SNLED-LD4-27SL-LW-UNV-L830-CD1-U 2732 120 25 WHITE C/B VOLTAGE: D C/S LITHONIA UN2-96T8-120-GEB 8550 120 118 WHITE F C/R METALUX 22CZ-LD4-24-UNV-L830-CD1-U 2220 120 23 WHITE G W/R GM LIGHTING STLS-LT-W LED 120 2 WHITE 1 20/1 H C/R METALUX 24CZ-LD4-40-UNV-L830-CD1-U 3941 120 34 WHITE 3 20/1 5 20/1 E0.1 1080 1080 42 C L A S S LOAD DESCRIPTION LOAD DESCRIPTION C L A S S R REC - BEDROOM #1 REC - KITCHEN R R REC - BEDROOM #2 REC - MICROWAVE R R REC - BEDROOM #3 REC - FRIDGE R R REC - BEDROOM #4 REC - FRIDGE R R REC - RRs, CORRIDOR REC - FRIDGE R R REC - RR, CORRIDOR REC - DINING, EXTERIOR R R REC - STORAGE REC - DISHWASHER R R REC - GARAGE REC - DISPOSAL R R REC - GARAGE SHORELINE REC - HOOD R R REC - GARAGE DOOR REC - CLOSET R R REC - GARAGE DOOR REC - CLOSET R R REC - GARAGE, EXTERIOR REC - LIVING AREA R R REC - WORKOUT ROOM REC - LIVING AREA R R REC - BSMT RR, LAUNDRY REC - LIVING AREA R H F-1 F.A.C.P. R A2 CU-1 PAGING SYSTEM R A2 -- LTG - GARAGE L L LTG - LIVING, DINING AREA LTG - BEDROOMS, CORR, RRs L R GRINDER PUMP LTG - BASEMENT L 20/1 SB W/S LUMARK XTOR6BRL-W-BZ-PC1 6133 120 58 BRONZE 9 20/1 SC UNIV GREENLEE (175W MH) 120 175 BLACK 11 20/1 SD C/R HALO H750ICAT-ML5612835-692SC 1570 120 18 SPEC-CLEAR 13 20/1 SE G/PL LEOTEK AR13-10M-MV-NW-3-DB-530 7380 120 65 DARK BRONZE 2 15 20/1 SF G/PL LEOTEK AR13-10M-MV-NW-2-DB-530 7380 120 65 DARK BRONZE 2 17 20/1^ 19 20/1 21 20/1 23 20/1 25 20/1 27 20/1 29 20/1 31 60/2 33 - ORDERING NOTES: 35 20/1 1. PROVIDE FINISH TO MATCH EXTERIOR COLOR OF BUILDING; VERIFY FINISH WITH OWNER. 2. PROVIDE 20'-0" SQUARE STRAIGHT STEEL POLE. 37 20/1 39 20/1 R SPARE LPA SF ABBREVIATIONS: 41 20/1 R SPARE LPA SF W/S SURE-LITES UNIV XR SURE-LITES UNIV SURE-LITES LEM2 - LPXH7 120 120 - SRP-25-BK - - WHITE - 120 WHITE - WHITE 1 GENERAL NOTES: A. ORDERING INFORMATION: THE ELECTRICAL CONTRACTOR SHALL REVIEW THE CONSTRUCTION DRAWINGS, BRANCH CIRCUIT VOLTAGE AND SUBMITTED LIGHTING FIXTURE SHOP DRAWINGS. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ORDERING THE CORRECT VOLTAGE FOR LIGHTING FIXTURES - NO EXCEPTIONS. INCORRECTLY SUBMITTED SHOP DRAWINGS AND FIXTURE ORDERS WITH THE INCORRECT FIXTURE VOLTAGE WILL NOT BE CAUSE FOR CONSTRUCTION DELAYS OR ADDITIONAL COSTS. 2 900 720 900 720 1000 1000 900 900 720 1000 3000 3000 TOTALS 750 250 10470 10330 #12 GA. SAFETY WIRE TIED TO SAFETY WIRE SUPPORT HOLES & FASTENED TO BLDG. STRUCTURE. MINIMUM (1) SAFETY WIRE AT CENTER OF FIXTURE FOR LIGHT FIXTURES LESS THAN 10 LBS. MINIMUM (2) SAFETY WIRES PLACED AT DIAGONAL CORNERS FOR LIGHT FIXTURES WEIGHING 10 LBS. OR MORE BUT LESS THAN 56 LBS. HOUSING + 12" VOLTAGE: E R TU FIX SEISMIC RESTRAINT CLIP MINIMUM (4) PER LIGHT FIXTURE, SECURELY AND POSITIVELY ATTACHED TO CEILING GRID, TYPICAL EMBEDING. COORDINATE WITH GENERATOR SHOP DRAWINGS. #5 REBAR, AT 12" O.C. EA WAY, PLACED IN CENTER OF 8" SLAB ANCHORS 8" GRADE SWAY BRACED GRID CEILING NOTES: 1. SUPPORT WIRES FOR FIXTURES WEIGHING LESS THAN 56 LBS. MAY BE INSTALLED SLACK. ALL OTHER SUPPORT WIRES SHALL BE INSTALLED TAUT WITH A MINIMUM OF 3 TIGHT TURNS AROUND ITSELF. 2. LIGHT FIXTURES WEIGHING 56 LBS. OR MORE SHALL BE INDEPENDENTLY SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE, BY APPROVED HANGERS. 36" EXCEPTION: LIGHT FIXTURES THAT ARE NOT COMPONENTS OF A STANDBY OR EMERGENCY LIGHTING SYSTEM AND WEIGH LESS THAN 20 POUNDS AND ARE POWERED USING FLEXIBLE CABLE CONNECTIONS NOT LESS THAN 3 FT. LONG CONNECTED TO THE FIXTURES, ARE NOT REQUIRED TO HAVE THE ADDITIONAL SUPPORT WIRE(S) DESCRIBED ABOVE. SUCH FIXTURES ARE REQUIRED TO BE POSITIVELY ATTACHED TO THE CEILING GRID AS DESCRIBED ABOVE. 2 1 12" GENERATOR CONCRETE PAD DETAIL 3 E0.1 NO SCALE LPA DESIGNATION/I.D: LIGHT FIXTURE SAFETY WIRE SUPPORT HOLE, TYPICAL 3 32" 120 / 240 STANDARD TOTAL SPACE REQUIRED: 2PSN FEEDER: SEE RISER DIAGRAM C/B 1 20/1 3 20/1 5 20/1 7 20/1 9 20/1 11 20/1 13 20/1 15 POWER SOURCE: 3 C 100 MAIN SWITCH: 2 20/1 4 20/1 6 20/1 8 20/1 10 20/1 12 20/1 14 20/1 16 20/1 18 20/1 20 20/1 22 20/1 24 20/1 26 20/1 28 20/1 30 20/1 32 20/1 34 20/1 36 20/1 38 100/2 40 - 42 1200 1000 1000 1000 1080 1200 500 500 360 360 900 540 900 180 180 1925 950 750 6290 6280 13360 0 CALC. DEMAND LOAD AMPERE: TOTALS 157A M.L.O. MAIN RATING AIC 10k NOTES: 30 "LP" PANEL LOAD DESCRIPTION LOAD DESCRIPTION C L A S S R GEN - BATTERY CHARGER WASHER R L LTG - EXTERIOR DRYER R L EXTERIOR SIGNAGE -- R M1 EF-B SP-1 R H IUH-1 WH-1 R R HW RECIRC PUMP GEN - BLOCK HEATER R L LTG - SITE POLES SPARE 20/1 R SPARE 17 20/1 R 19 20/1 21 C/B C K T # 20/1 2 30/2 4 - 6 20/1 8 20/1 10 20/1 12 R 20/1 14 SPARE R 20/1 16 SPARE SPARE R 20/1 18 R SPARE SPARE R 20/1 20 20/1 R SPARE SPARE R 20/1 22 23 20/1 R SPARE SPARE R 20/1 24 25 20/1 R SPARE SPARE R 20/1 26 27 20/1 R SPARE SPARE R 20/1 28 29 20/1 R SPARE SPARE R 20/1 30 TOTALS 1000 500 1000 1610 600 180 500 3100 CONNECTED LOAD: (VOLT-AMPERE) 2290 0 LOAD (WATTS) 1000 2500 2500 180 180 1500 3680 NOTES: * PROVIDE LOCK ON DEVICE ** 10,000 A.I.C. RATING UNLESS OTHERWISE SPECIFIED 13,250VA 4180 0 CALC. DEMAND LOAD AMPERE: TOTALS 57A CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE, A1=1PH A/C LOAD, A2=2PH A/C LOAD, A3=3PH A/C LOAD, H=HEATING, K=KITCHEN; XF=TRANSFORMER-PANEL; SF=SUB-FEED RECESSED LIGHTING FIXTURE SUPPORT DETAIL NO SCALE 4 5 HOT 20/1 1080 MOUNTING: SURFACE C L A S S LOAD (WATTS) "SLC" ET CIRCUIT BREAKER ** BUS SIZE (AMPS): POLES: C K T # LUGS: TYPE OF PANEL: /1PH-3W # "TC" C K T # CLASS: M1=SINGLE PH MOTOR, M3=3PH MOTOR, M2=2PH MOTOR, L=LIGHTING, R=RECEPTACLE, A1=1PH A/C LOAD, A2=2PH A/C LOAD, A3=3PH A/C LOAD, H=HEATING, K=KITCHEN; XF=TRANSFORMER-PANEL; SF=SUB-FEED LI 3 * PROVIDE LOCK ON DEVICE ** 10,000 A.I.C. RATING UNLESS OTHERWISE SPECIFIED ^ GROUND FAULT BREAKER C/B LOAD (WATTS) 14815 48,975VA 10k PANELBOARD SCHEDULE T GH HOUSING + 12" 0 NOTES: STRUCTURE HILTI CC27 CLIP (OR EQUAL) MAIN RATING AIC "ATS" 7 720 M.L.O. NOTES: BRONZE RDB-175MH-120-SPV-BLR 1080 MAIN SWITCH: 26 NO SCALE E0.1 POWER SOURCE: 1080 CONNECTED LOAD: (VOLT-AMPERE) 6" MIN. TOTAL SPACE REQUIRED: STANDARD LOAD (WATTS) 200 120 GROUNDING ELECTRODE SYSTEM 2 LUGS: MOUNTING: SURFACE 2710 C/AC CEILING AIR-CRAFT CABLE, C/CV CEILING COVE, C/P CEILING PENDANT, C/R CEILING RECESSED, C/S CEILING SURFACE, C/SP CEILING SUSPENDED, C/TK TRACK MOUNTED, F/S FLOOR SURFACE, G/P GRADE PAD, G/PL GRADE POLE, R/S ROOF SURFACE, TBD TO BE DETERMINED, U/C UNDER COUNTER, UNIV. UNIVERSAL, W/R WALL RECESSED, W/S WALL SURFACE 1 120 / 240 CIRCUIT BREAKER ** XTOR3B-W-BZ-PC1 X 5. ALL GROUNDING AND BONDING SHALL BE INSTALLED IN ACCORDANCE WITH ARTICLE 250 OF NFPA 70 THE "NATIONAL ELECTRICAL CODE". BUS SIZE (AMPS): 2BCLED-LD4-20SL-F-UNV-L830-CD1-U NOTES LUMARK NOTE: 1. EXOTHERMIC WELD DESIGNATION INDICATED ABOVE ARE ERICO "CADWELD". ALL CONNECTIONS SHALL BE EXOTHERMIC WELD OR UL LISTED MECHANICAL CONNECTIONS. 4. GROUND RODS ARE TO BE LOCATED AT SERVICE ENTRANCE WITH SIZE AS NOTED. /1PH-3W FINISH C K T # EM 3. ALL WIRING SHALL BE COPPER AND TYPE THHN/THWN GREEN INSULATION WHERE REQUIRED.. TYPE OF PANEL: INPUT WATTS W/S FOUNDATION CONTRACTOR SHALL STUB-UP RE-BAR FROM FOUNDATION FOR USE BY THE E.C. TYPE "VS" CONNECTION OR APPROVED CONNECTOR. E.C. SHALL COORDINATE WITH FOUNDATION CONTRACTOR. 2. ALL GROUND BUS CONNECTIONS TO BE MADE WITH 2-HOLE COMPRESSION TYPE CONNECTORS. BUS SHALL BE INSULATED FROM ITS SUPPORT AND SHALL MAINTAIN A 2" SPACING FROM WALL. LP VOLTAGE SA #4 COPPER CLAD GROUND ROD TYPICAL, 5/8"x10'. DESIGNATION/I.D: LUMENS (LAMPS) MODEL NO. PLAN NOTES - RISER DIAGRAM 1. PROVIDE 4" SCHEDULE 40 PVC CONDUIT FOR UTILITY COMPANY'S PRIMARY CABLES FROM EXISTING UNDERGROUND POWER TO UTILITY TRANSFORMER AS DIRECTED BY UTILITY CO. REPRESENTATIVE. REFER TO SITE PLAN FOR ADDITIONAL INFORMATION. 2. 3 #3/0 & 1 #6 GRD, 2"C. 3. AMEREN APPROVED NEMA 3R METERING ENCLOSURE. REFER TO AMEREN ELECTRIC SERVICE MANUAL FOR SPECIFICATIONS. 4. 200A/2PSN FUSIBLE SWITCH, 200A FUSES, NEMA 1 ENCLOSURE AND GROUNDING KIT. TERMINAL (TYP.) 120V NEUTRAL "PC" PROVIDE LOCK-ON DEVICE FOR C.B. (SPARE) UTILITY XFMR M FROM PANEL - SEE PLANS FOR CIRCUITS TO LOADS - SEE PLANS FOR CIRCUITS ("PC" - ON, "TC" - OFF) GENERATOR 3 5. GRADE 1 "PC" - PHOTOCONTROL: INTERMATIC #K4121C. LAUNDRY 003 2 "TC" - TIME CLOCK: INTERMATIC #ET-1725 WITH TWO SPST LOADS * PROGRAM TIME CLOCK PER OWNER'S DIRECTIONS 5 "ATS" "SLC" - SITE LIGHTING CONTACTOR: ASCO #918-4-20-31, 47L, C 4 POLES, 20 AMPS, MECHANICALLY-HELD, 120 VOLT/2-WIRE CONTROL, NEMA 1 ENCLOSURE 2 4 "LP" 6 4 E0.1 LIGHTING CONTROL DIAGRAM NO SCALE 2-POLE WITH SOLID NEUTRAL IN NEMA 1 ENCLOSURE. KOHLER #: RDT-CFNA-0200 OR EQUAL. 11 5 E0.1 RISER DIAGRAM NO SCALE BASEMENT 2 "LPA" 7 2 1 E0.1 9 10 8 6. PANELBOARD "LP": 200A M.L.O. 7. 3 #3 & 1 #8 GRD, 1-1/4"C. 8. PANELBOARD "LPA": 100A M.L.O. 9. PROVIDE AND ROUTE 3 #3/0 & 1 #6 GRD, 2"C FROM "ATS" TO GENERATOR. 10. ROUTE CONTROL WIRING FROM GENERATOR TO "ATS". 11. GENERATOR SPEC: KOHLER MODEL # 48RCL WITH ALERNATOR "4Q7BX". 48 KW, 120/240V, 1PH, 3W WEATHERPROOF HOUSING, NATURAL GAS FUEL. INTEGRAL BATTERY, BATTERY CHARGER, MUFFLER, 200 AMP C/B. MOUNT GENERATOR/TANK ON CONCRETE PER DETAIL 2/E0.1. COORDINATE EXACT SIZE OF PAD WITH GENERATOR HOUSING APPROVED SUBMITTALS. 06-21-2017