 RLH Industries, Inc. rugged fiber optic technology. USER GUIDE U-016 2017A-0412 10/100 Ethernet 
 Fiber Link Card System SYSTEM INSTALLATION INFORMATION Description The 10/100 Ethernet Fiber Link Card system converts a copper 10Base-T or 100Base-TX to a fiber optic 100Base-FX transmission signal of either multimode or single-mode. The cards transmit the data signals over fiber optic cable, allow for network extension over long distances, and provide electrical isolation between both ends of the network. The Ethernet Fiber Link Card may be used as a complete system, with a card at each end, or it may be connected directly to any 100Base-FX device. The card includes Link Fault Passthrough (LFP) mode with an LED indicator for 
 link loss failure that allows for rapid fault isolation. 
 This hardened, substation grade system is covered by 
 our Limited Lifetime Warranty. Note: The cards listed in this document replace all other models. See the ordering section for part number information. &-) ) Contents Description ____________________________1 Key Features ___________________________ 1 General Safety Practices _________________ 2 Applications ___________________________ 3 Key Features 10/100 Ethernet Fiber Link Card Acronyms _____________________________ 4 • Ideal for critical, high voltage, remote or un-manned
 locations that must remain operating 24/7/365 • Compatibility with IEEE 802.3 10 Base-T UTP, 100Base-TX, and 100Base-FX Devices • RJ45 UTP port with 10//100 auto-negotiation LED Indicators _________________________ 6 • Extends network span up to 1.2 miles (2km) on multimode and up to 74 miles (120km) on single-mode fiber Specifications __________________________7 • Convenient LED status indicators Technical Support ______________________8 • Link alarm function for status monitoring • Dual and Single (bi-directional) fiber models available • Environmentally hardened to operate in -40°F to +158°F
 (-40°C to +70°C) environments • Standard RLH fiber link card form factor • Covered by our Limited Lifetime Warranty Installation _____________________________ 4 DIP Switch Settings _____________________ 5 Troubleshooting ________________________6 Ordering Information ____________________8 RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page " 1 General Safety Practices The equipment discussed in this document may require tools designed for the purpose being described. RLH recommends that service personnel be familiar with the correct handling and use of any installation equipment used, and follow all safety precautions including the use of protective personal equipment as required. Caution - Severe Shock Hazard • Never install during a lightning storm or where unsafe high voltages are present. • Use caution when handling copper wiring and follow appropriate safety regulations. Special handling requirements Be careful when handling electronic components ATTENTION " ELECTROSTATIC SENSITIVE DEVICES • This product contains static sensitive components. • Handle Fiber Link cards at their edges only. • Follow proper electrostatic discharge procedures. This card utilizes circuitry that can be damaged by static electricity. When transporting the card, carry it in an ESD safe container such as the antistatic bag provided with the card. Before handling cards, discharge yourself of static electricity by physical bodily contact with earth ground. When handling cards, hold by outer edges and avoid touching circuitry. Failure to follow ESD precautions may cause serious damage to the card and prevent proper operation. Guidelines for handling terminated fiber cable " Page 2 • Do not bend fiber cable sharply. Use gradual and smooth bends to avoid damaging glass fiber. • Keep dust caps on fiber optic connectors at all times when disconnected. • Do not remove dust caps from unused fiber. • Keep fiber ends and fiber connectors clean and free from dust, dirt and debris. Contamination will cause signal loss. • Do not touch fiber ends. • Store excess fiber on housing spools or fiber spools at site RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Applications Network equipment in high voltage areas can be at risk due to Ground Potential Rise (GPR). A copper network cable referenced to a remote ground can become a path for high voltages during a ground fault. Placement of all-dielectric fiber optic cable (instead of copper) completely eliminates the presence of a remote ground, which dramatically increases safety of personnel and reliability of equipment. By utilizing fiber optic cable, the Ethernet FIber Link Card provides absolute electrical isolation between both ends of the network. Copper twisted pair Ethernet is limited to 100m/328ft without extenders. Fiber optic cable provides long distance service (up to 120km/74mi.) without any additional equipment. Fiber is immune to EMI/RF interference, ground loops, and high voltage surges from lightning or ground faults, and is ideal in electrically noisy environments such as near large power sources, electrical motors, and radio communications equipment. RLH Ethernet over Fiber Card Network or Ethernet Device ! Ethernet RLH Ethernet over Fiber Card Fiber Optic Cable Up to 36mi. / 60km 24 - 56VDC Power Supply Ethernet Network or Ethernet Device 24 - 56VDC Power Supply Typical Ethernet System Diagram 10/100 ETHERNET CARD TX RX O N 1 2 3 4 5 6 LP MAN 10 HDX HDX ON LS AN 100 FDX FDX RST FSD FXL FDX PWR TDX FEFD UTP 10/100 DC POWER 24~56VDC MDL-02 ! Ethernet Fiber Link Card Front Panel RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page " 3 Acronyms Commonly used acronyms and abbreviations Acronym/Abbreviation UTP Description Unshielded Twisted Pair (commonly used in Ethernet networks) TP Twisted Pair (same as UTP) LFP Link Fault Passthrough TX Transmit RX Receive MAN Manual AN Auto Negotiating HDX Half Duplex FDX Full Duplex LS Link Fault Passthrough Suspend LP Link Fault Passthrough Pass Installation Prior to installation: • • • Check for shipping damage Check the contents to ensure correct model and fiber type Have a clean, dry installation environment ready Required for installation: • • 24-56VDC (3W minimum) power source RLH Fiber Link Card housing Measure the DC voltage of the source power to ensure that it is 24-56VDC (3W minimum). All electrical and fiber optic connection are made directly onto the card. The Ethernet fiber link card is designed to be installed into any RLH card housing. Connect fiber optic cable Multimode and single-mode Ethernet cards are equipped with either two ST or SC female optical connectors, or a single SC bi-directional connector. Connect fiber cable to the Transmit (TX) and Receive (RX) optical connectors. The other end of the fiber may be connected to another Ethernet fiber link card or any 100BASE-FX Ethernet device. The TX connector of each card must be connected the RX connector at the other end. For bi-directional, single fiber models, there is only a single SC connector used for both transmitting and receiving. Always route fiber optic cable loosely avoiding tight bends. Connect Ethernet cable The TP (RJ-45) Ethernet port will auto-sense for 10Base-T or 100Base-TX connections.
 The port is auto MDI/MDIX, which means that the card can connect to another card, switch or workstation without changing straight through or crossover cabling. Page 4 RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Connect Power Connect a 24-56VDC (200mA minimum) power source to the screw-down terminal on the Ethernet card. The power input is not polarity sensitive. The terminal unplugs from the card to make wiring easier. DIP Switch Settings The front panel DIP switches may be set for optional modes. The factory default is OFF for all switches. Ethernet DIP Switch Settings ON O N 1 2 3 4 5 6 LP MAN 10 HDX HDX ON " Switch Description 1 Link Fault Pass-through 2 3 TP Port Mode
 TP Port Speed 4 TP Port Duplex 5 Fiber Port Duplex 6 Reset LS AN 100 FDX FDX RST Setting Function LP LFP enabled (Default) LS LFP disabled AN TP is auto negotiating (Default) MAN Force TP at 10M or half duplex 100 TP at 100M (Default) 10 TP at 10M when TP Port Mode is set to MAN (Force 10M) FDX TP at full duplex (Default) HDX TP at half duplex when Port Mode at Force FDX Fiber port at full duplex (Default) HDX Fiber port at half duplex ON Power on (Default) RST Recycle power (See note) After changing any of the DIP switches, recycle the power to the card by flipping switch 6 (Reset) from RST to ON then back to RST. DIP switch 2 must be set to MAN (ON) when switches 3 and 4 are set to 10 and HDX respectively. Note: Connecting an auto-negotiating device to a non-auto-negotiating device may result in an unpredictable port setting with poor link performance. When operating in Manual mode, both mating ports must be set to the same data rate and duplex mode. RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page " 5 RX 1 2 3CARD 4 5 6 10/100 ETHERNET O N 10/100 ETHERNET CARD Troubleshooting TX If trouble is encountered, verify all copper and fiber connections and settings. If any of the DIP switches TX were changed, you must recycle the power by flipping switch 6 to RST (Reset) and ON again to enable the settings. Refer to the LED Indicators on the front panel,LPthey show LS availability of power, modes of AN MAN operation, and data being received by the fiber and TP port. TX O N 1 2 3 4 5 6 LP MAN 10 HDX HDX ON LS AN 100 FDX FDX RST FXL FDX FEFD DC POWER 24~56VDC MDL-02 LINK/ACT ON GRN TDX GRN GRN 10/100 ORG LINK/ACT GRN Fiber port link OK and activity is present Fiber port link fail ON Fiber port at full duplex OFF Fiber port at half duplex Fiber port at half duplex and collisions occurring ON Fiber signal detected OFF Fiber disconnected OFF Normal operation Blinking Far end fault detected ON TP port at full duplex OFF TP port at half duplex Blinking PWR Description OFF Blinking FEFD Fiber port link OK TP port at half duplex and collisions occurring ON Card power is ON OFF Card power is OFF ON TP port speed is 100M OFF TP port speed is 10M ON TP port link OK Blinking OFF DC POWER Blinking 24~56VDC DC POWER 24~56VDC GRN MDL-02 FXL MDL-02 LED GRN FEFD UTP 10/100 UTP 10/100 10/100 Color FSD FSD UTP 10/100 PWR TDX Indicator GRN LS AN FSD FEFD FDX PWR TDX RX 100 FDX FDX RST PWR FXLTDX FSD FXL FDX FDX LP MAN 10 HDX HDX ON 1 2 3 4 5 6 RX 100 FDX FDX RST O N 10/100 ETHERNET CARD 10 HDX HDX ON TP port link OK and activity is present TP port link not present If trouble persists, replace the unit and retest. If technical assistance is required, contact the RLH technical support department: 800-877-1672 (6 am to 6 pm- PST),
 or call our 24/7 Technical/Customer Service: (714) 366-2503 or (714) 457-5740 Page 6 RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com General Specifications Protocols Copper Connector Copper Distance Fiber Connector Dual Fiber Optics Single Fiber Optics
 (Bi-directional) LED Indicators Power Input Dimensions Temperature Humidity Warranty 100BASE-FX, 10BASE-T, or 100BASE-TX RJ45 UTP 100m / 328 feet ST or SC (Dual fiber or single fiber (bi-directional) connectors) Fiber Type Multimode Single-mode Wavelength TX/RX 1310 1310 1310 1550 (nm) Distance 2km / 1.2 mi. 20km / 12 mi. 60km / 36 mi. 120km / 74 mi. Min. TX PWR (dBm) -18 -15 -6 0 Max. TX PWR (dBm) -10 -8 -3 +5 RX Sensitivity (dBm) -31 -34 -34 -34 Link Loss Budget 13 19 28 34 (dBm) Fiber Type Multimode Single-mode Wavelength (nm) 1310/1550 1310/1550 1310/1550 Distance 2km / 1.2 mi. 20km / 12 mi. 60km / 36 mi. Min. TX PWR (dBm) 2-17 -14 -9 Max. TX PWR (dBm) -10 -8 -5 RX Sensitivity (dBm) -31 -34 -34 Link Loss Budget 14 20 25 (dBm) FXL (Fiber) Fiber port link - ON: link OK, OFF: link fail, Blink: activity FDX (Fiber) Fiber port full duplex - ON: full, OFF: half, Blink: half & collisions FSD Fiber signal detect - ON: signal detected, OFF: fiber disconnected Far end fault detection - OFF: normal operation, Blinking: far end fault FEFD detected TDX TP port full duplex - ON: full, OFF: half, Blink: half & collisions PWR Power - ON: power applied, OFF: no power 10/100 TP port speed - ON: 100m, OFF: 10M LINK/ACT TP port link - ON: link OK, OFF: no link, Blink: activity 24~56VDC @ 3W 7”x 4”x1” (Standard RLH Fiber Link Card form factor) Operating -40˚F to +158˚F (-40˚C to +70˚C) Storage -40˚F to +176˚F (-40˚C to +80˚C) 5~95% non-condensing Limited Lifetime Visit www.fiberopticlink.com for warranty details RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com Page " 7 Ordering Information Each Fiber Link Card is identified by the part number. Optics Side Distance Wavelength Fiber Part Number Multimode ST - 2 km/1.2 mi 1310 nm 62.5/50 µm Multimode SC A B - 2 km/1.2 mi 2 km/1.2 mi 2 km/1.2 mi 20km/12.4mi. 60km / 37mi. 120km / 74 mi. 1310 nm Tx 1310 nm / Rx 1550 nm Tx 1550 nm / Rx 1310 nm 1310 nm 1310 nm 1550 nm 62.5 µm 62.5 µm 62.5 µm 8~9 µm 8~9 µm 8~9 µm EF4-04-2 EF4-03-2 A B 20km/12.4mi. 60km / 37mi. 120km / 74 mi. 20km/12.4mi. 20km/12.4mi. 1310 nm 1310 nm 1550 nm Tx 1310 nm / Rx 1550 nm Tx 1550 nm / Rx 1310 nm 8~9 µm 8~9 µm 8~9 µm 8~9 µm 8~9 µm EF4-40-2 EF4-41-2 EF4-45-2 EF4-10-2 EF4-11-2 A B 60km / 37mi. 60km / 37mi. Tx 1310 nm / Rx 1550 nm Tx 1550 nm / Rx 1310 nm 8~9 µm 8~9 µm EF4-14-2 EF4-15-2 Bi-Directional
 Multimode SC Single-mode
 ST Single-mode
 SC Bi-Directional
 Single-mode SC EF4-01-2 EF4-02-2 EF4-50-2 EF4-51-2 EF4-55-2 Optics are dual fiber unless connectors are Bi-Di. Bidirectional single fiber models require both an A Side and B Side unit for a complete system. Please contact your RLH sales representative for pricing and delivery information. Technical Support Email: [email protected] 24/7 technical support: Toll Free 1-855-RLH-24X7 Toll Free 1-855-754-2497 Contact Information Corporate Headquarters: RLH Industries, Inc. 936 N. Main Street Orange, CA 92867 USA Phone: (714) 532-1672 Toll Free 1-800-877-1672 Toll Free 1-866-DO-FIBER
 Fax: (714) 532-1885 Email: [email protected] Web site: www.fiberopticlink.com RLH Industries, Inc. 936 N. Main Street, Orange, CA 92867 USA T: (714) 532-1672 F: (714) 532-1885 " Page 8 Please contact your RLH sales representative for pricing and delivery information. Specifications subject to change without notice. RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com