Transcript
Model 10/10B-HS High-Voltage Power Amplifier ! Output Voltage Range
0 to ±10 kV 4
! Output Current Range
0 to ±10 mA DC, with a 40 mA peak for 1 ms
-HS
! Slew rate greater than The Trek Model 10/10B-HS is a DC stable high-voltage power amplifier capable of precise control of output voltages in the range of 0 to ±10 kV DC or peak AC with an output current range of 0 to ±10 mA DC or 40 mA peak AC for 1 ms. The Model 10/10B-HS is configured as a noninverting amplifier with a fixed gain of 1000 V/V. Industrial and R&D applications include AC or DC biasing, atmospheric plasma, dielectric barrier discharge, electroactive polymers (EAP), electrophoresis, electrophotography, electrorheological fluids, electrostatic deflection, electro-optic modulation, ferroelectric material characterization, ion beam steering, mass spectrometers, material poling and particle accelerators. The Model 10/10B-HS features an all-solid-state design for high slew rate, wide bandwidth and low-noise operation. The fourquadrant, active output stage sinks or sources current into reactive or resistive loads throughout the output voltage range. This is essential for achieving the accurate output response and high slew rates demanded by reactive loads. The Model 10/10B-HS is protected against over-voltage and overcurrent conditions that may be generated by active loads or by output short circuits to ground.
700 V/µs ! Dynamic Adjustment
for optimizing AC response ! Remote high-voltage
ON/OFF capability ! Adjustable current
limit or current trip ! Precision Voltage and
Current Monitors Provide Low-Voltage Representations of the 10/10B-HS Output
Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes, or for use as feedback signals in a closed-loop system. The remote high voltage on/off feature provides a connection for a remote device to turn on and off the high-voltage output. This makes the Model 10/10B-HS suitable for automated or computercontrolled systems. The Model 10/10B-HS can be operated on a bench top or in a standard 19-inch rack.
!
Compliant
Measurement and Power SolutionsTM www.trekinc.com
Model 10/10B-HS Specifications All specifications are with no load unless otherwise noted.
Output Output Voltage Range 0 to ±10 kV DC or peak AC. Output Current Range 0 to ±10 mA DC or ±40 mA peak for 1 ms. (See Automatic Power Limit feature for limitations.)
Amplifier Input Input Voltage Range 0 to ±10 V DC or peak AC. Input Impedance 20 kW , nominal.
Features High-Voltage On/Off Switch selectable for either local or remote control. Local Individual push-button switches. Remote A TTL compatible input. A TTL high (or open) turns off the high-voltage output. A TTL low turns on the highvoltage output. Dynamic Adjustment A graduated one-turn panel potentiometer is used to optimize the AC response of the Model 10/10B-HS for various load parameters. Current Limit/Trip Switch selectable for either limit or trip. A graduated one-turn panel potentiometer is used to adjust the limit or trip level from 0 to ± 10 mA. Out of Regulation Status Indicator and Connector An indicator will illuminate and a BNC will provide a TTL low when the Model 10/10B-HS fails to produce the required high-voltage output such as during current limit. Fault/Trip Status Indicator and Connector An indicator will illuminate and a BNC will provide a TTL low when the high-voltage is disabled due to the set current trip level being exceeded or the internal interlock circuit being interrupted, such as by removal of the cover. This BNC connector will also provide a TTL low when the amplifier is out of regulation for more than 500 ms, such as during a current limit. However, in this instance the high-voltage output is not disabled. Voltage Monitor A buffered output provides a low-voltage replica of the high voltage output.
Features (cont.) Scale Factor 1 V/1000 V. DC Accuracy Better than 0.1% of full scale. Offset Voltage Less than ±3 mV. Output Noise Less than 20 mV rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter). Output Impedance 47 W . Current Monitor A buffered output provides a low-voltage representation of the load current. Scale Factor 1 V/4 mA. DC Accuracy Better than 1 % of full scale. Offset Voltage Less than ±10 mV. Output Noise Less than 50 mV rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter). Bandwidth (-3db) DC to greater than 10 kHz. Output Impedance 47 W .
Performance DC Voltage Gain 1000 V/V. DC Voltage Gain Accuracy Better than 0.1% of full scale. Offset Voltage Less than ±2 V. Output Noise Less than 0.5 V rms (measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter). Slew Rate (10% to 90%, typical) Greater than 700 V/µs. Large Signal Bandwidth(-3dB) DC to greater than 19.5 kHz. Large Signal Bandwidth(1% distortion) DC to greater than 9.5 kHz. Small Signal Bandwidth (-3dB) DC to greater than 60 kHz. Settling Time (to 1%) Less than 100 µs for a 0 to 10 kV step. Stability Drift with Time Less than 100 ppm/hr, noncumulative. Drift with Temperature Less than 100 ppm/°C.
Performance (cont.) Automatic Power Limit Automatically limits the internal power dissipation to protect the Model 10/10B-HS from overheating. The following graph illustrates the automatic power +10 limit output capability. mA
+10 kV
-10 kV
-10 mA
AC Operating Range (frequencies above 50 Hz, 50% duty cycle, and no DC offset) DC Operating Range
General Dimensions 190 mm H x 432 mm W x 417 mm D (7.5" H x 17" W x 16.4" D). Weight 14.9 kg (31 lb). High-Voltage Output Connector Alden high-voltage connector. BNC Connectors Amplifier Input Voltage Monitor Current Monitor Remote High-Voltage On/Off Out of Regulation Status Fault/Trip Status connector Power Requirements Line Voltage Factory set for one of two ranges: 90 to 127 V AC or 180 to 250 V AC, at 48 to 63 Hz (specify when ordering). Power Consumption 680 VA, maximum. AC Line Receptacle Standard three-prong AC line connector with integral fuse holder.
Included Accessories Operator’s Manual, HV Output Cable, Line Cord (90 to 127V AC operation), Unterminated Line Cord* (180 to 250V AC operation). *Line cord type determined by the geographical destination of the unit. Optional Accessories HV Output Cable in varying lengths, 19-in Rack Mount Kit(s) Copyright ã 2011 TREK, INC. All specifications are subject to change. 1121/DEC
TREK, INC. 11601 Maple Ridge Road • Medina, NY 14103 • USA • 800-FOR TREK 585-798-3140 • 585-798-3106 (fax) • www.trekinc.com •
[email protected]