Datasheet 40GbE QSFP+ Direct Attach Passive Copper Cable 2M QQ-PC-30-2-xx Features  40 Gb/s total bandwidth  4 independent duplex channels operating at 10Gbps, 2.5Gbps or 5Gbps data rates  AC coupling of PECL signals  100 ohm differential impedance system  Lower Power Consumption< 2W  Power Supply +3.3V  Low Near-End Crosstalk  Fully compatible with IEEE802.3ba and Infiniband QDR specifications  Temperature Range -40 to 85°C  All-metal housing for superior EMI performance  Precision process control for minimization of pair-to-pair skew  EEPROM for cable signature & system communications  Compliant QSFP MSA specifications  RoHS6 compliant Applications  Networked storage systems  External storage systems  Data Center networking  Hubs, Switches, Routers, Servers Description 40G QSFP+ copper direct-attach cables are suitable for very short distances and offer a highly cost-effective way to establish a 40-Gigabit link between QSFP+ ports of QSFP+ switches within racks and across adjacent racks. These cables are used for 40GbE and Infniband standards, to maximize performance. QSFP+ are designed to meet emerging data center and high performance computing application needs for a high density cabling interconnect system capable of delivering an aggregate data bandwidth of 40Gb/s. This interconnect system is fully compliant with existing industry standard specifications such as the QSFP MSA and IBTA (InfiniBand Trade Association). The QSFP+ cables support the bandwidth transmission requirements as defined by IEEE 802.3ba (40 Gb/s) and Infiniband QDR (4x10 Gb/s per channel) specifications. 1 Datasheet Specifications Table 1 - Absolute Maximum Ratings Parameter Symbol Min Storage Temperature Tst Max Units -40 125 °C RS - 85 % Operating Case Temperature Topc -40 85 °C Supply Voltage VCC3 -0.3 3.6 V Voltage on LVTTL Input Vilvttl -0.3 Relative Humidity (non-condensation) Typ 3.3 VCC3 Note Note1 V +0.2 Notes: Note1: Stress or conditions exceed the above range may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not applied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Table 2 - Normal operating condition Parameter Symbol Min Operating Case Temperature Topc Relative Humidity (non-condensation) Typ Max Units -40 85 °C RS - 85 % Supply Voltage VCC3 3.135 3.465 V Power Supply Current ICC3 750 - mA Total Power Consumption Pd - 2.0 W 3.3 Table 3 - Regulatory Compliance Feature Standard MIL-STD-883G Electrostatic Discharge (ESD) to the Electrical Pins Method 3015.7 Performance Class 1C (>1000 V) EN 55024:1998+A1+A2 Electrostatic Discharge to the enclosure IEC-61000-4-2 Compatible with standards GR-1089-CORE Compatible with standards Noise frequency range: FCC Part 15 Class B 30MHz to 6GHz. Good system EN55022:2006 EMI design practice required CISPR 22B :2006 to achieve Class B margins. VCCI Class B System margins are dependent on Electromagnetic Interference (EMI) customer host board and chassis design. 2 Datasheet Compatible with standards. 1KHz sine-wave, 80% AM, Immunity EN 55024:1998+A1+A2 from 80MHz to 1GHz. No IEC 61000-4-3 effect on transmitter/receiver performance is detectable between these limits. FDA 21CFR 1040.10 and Laser Eye Safety 1040.11 EN (IEC) 60825-1:2007 EN (IEC) 60825-2:2004+A1 UL and CUL Component Recognition RoHS6 EN60950-1:2006 2002/95/EC 4.1&4.2 2005/747/EC 5&7&13 CDRH compliant and Class I laser product. TüV Certificate No. 50135086 UL file E317337 TüV Certificate No. 50135086 (CB scheme ) Compliant with standards*note2 Notes: Note2: For update of the equipments and strict control of raw materials, Fiberstore has the ability to supply the customized products since Jan 1th, 2007, which meet the requirements of RoHS6 (Restrictions on use of certain Hazardous Substances) of European Union. In light of item 5 in RoHS exemption list of RoHS Directive 2002/95/EC, Item 5: Lead in glass of cathode ray tubes, electronic components and fluorescent tubes. In light of item 13 in RoHS exemption list of RoHS Directive 2005/747/EC, Item13: Lead and cadmium in optical and filter glass. The three exemptions are being concerned for Fiberstore’s transceivers, because Fiberstore’s transceivers use glass, which may contain Pb, for components such as lenses, windows, isolators, and other electronic components. 3 Datasheet Pin Assignments and Descriptions Pin No. Logic 1 Symbol Name/Description Note GND Ground 3 2 CML-I Tx2n Transmitter Inverted Data Input 3 CML-I Tx2p Transmitter Non-Inverted Data output GND Ground 4 5 CML-I Tx4n Transmitter Inverted Data Input 6 CML-I Tx4p Transmitter Non-Inverted Data output GND Ground 7 8 LVTLL-I ModSelL Module Select 9 LVTLL-I ResetL Module Reset Vcc Rx ﹢3.3V Power Supply Receiver SCL 2-Wire Serial Interface Clock 10 11 LVCMOS-I/O 4 3 3 4 Datasheet 12 LVCMOS-I/O 13 SDA 2-Wire Serial Interface Data GND Ground 14 CML-O Rx3p Receiver Non-Inverted Data Output 15 CMLO Rx3n Receiver Inverted Data Output GND Ground 16 3 17 CMLO Rx1p Receiver Non-Inverted Data Output 18 CMLO Rx1n Receiver Inverted Data Output 19 GND Ground 3 20 GND Ground 3 21 CMLO Rx2n Receiver Inverted Data Output 22 CMLO Rx2p Receiver Non-Inverted Data Output GND Ground 3 3 23 24 CMLO Rx4n Receiver Inverted Data Output 25 CMLO Rx4p Receiver Non-Inverted Data Output GND Ground 26 3 27 LVTTLO ModPrsL Module Present 28 LVTTLO IntL Interrupt 29 Vcc Tx +3.3 V Power Supply transmitter 4 30 Vcc1 +3.3 V Power Supply 4 LPMode Low Power Mode GND Ground 31 LVTTLI 32 33 CMLI Tx3p Transmitter Non-Inverted Data Input 34 CMLI Tx3n Transmitter Inverted Data Output GND Ground Tx1p Transmitter Non-Inverted Data Input 35 36 CMLI 5 3 3 Datasheet 37 38 CMLI Tx1n Transmitter Inverted Data Output GND Ground 3 Notes: Note3: GND is the symbol for signal and supply (power) common for QSFP modules. All are common within the QSFP module and all module voltages are referenced to this potential otherwise noted. Connect these directly to the host board signal common ground plane. Note4: Vcc Rx, Vcc1 and Vcc Tx are the receiver and transmitter power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown below. Vcc Rx, Vcc1 and Vcc Tx may be internally connected within the QSFP transceiver module in any combination. The connector pins are each rated for a maximum current of 500mA. Recommended power supply filtering Example A typical host board mechanical layout for attaching the QSFP transceiver is presented below. The recommended host electrical connector should be a 38-pin IPASS right angle connector assembly (example: Tyco PN: 1761987-9) and the cage assembly should be QSFP single cage (example: Tyco PN: 1888617-1). 6 Datasheet Recommended PCB layout A typical host board mechanical layout for attaching the QSFP transceiver is presented below. The recommended host electrical connector should be a 38-pin IPASS right angle connector assembly (example: Tyco PN: 1761987-9) and the cage assembly should be QSFP single cage (example: Tyco PN: 1888617-1). 7 Datasheet Mechanical Specifications Ordering Information Part No. Data Rate (Gbps) Length (m) AWG Passive / Active Temp. Range (°C) Package QQ-PC-30-0.5-xx 40 0.5 30 Passive -40 to +85 QSFP+ to QSFP+ QQ-PC-30-1-xx 40 1 30 Passive -40 to +85 QSFP+ to QSFP+ QQ-PC-30-2-xx 40 2 30 Passive -40 to +85 QSFP+ to QSFP+ QQ-PC-30-3-xx 40 3 30 Passive -40 to +85 QSFP+ to QSFP+ Notes: xx means compatible brand. (For example: CO= Cisco, JU=Juniper, FD=Foundry, EX=Extreme, NE=Netgear.) 8 Datasheet FiberStore U.S. FiberStore Hong Kong FiberStore China X205 4181 129th Place SE, Bellevue 1220 Tung Chun Commercial Centre, 5D Intelligent Tower, 98006, WA, 438-444 Shanghai Street, Kowloon, Fumin Road Futian, United States HongKong Shenzhen 518045, GuangDong, Tel: +1 (206) 453 0158 Tel: (852) 8120 3582 China Fax: +1 (425) 505 2761 Fax: (852) 8120 3582 Tel: +86 (755) 8300 3611 Fax: +86 (755) 8326 9395 Addresses, phone number and fax number also have been listed at www.fiberstore.com. Please e-mail us at [email protected] or call us for assistance. All statements, technical information, and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact FiberStore for more information. 9