Transcript
Datasheet
40GbE QSFP+ Direct Attach Passive Copper Cable 2M QQ-PC-30-2-xx
Features
40 Gb/s total bandwidth
4 independent duplex channels operating at 10Gbps, 2.5Gbps or 5Gbps data rates
AC coupling of PECL signals
100 ohm differential impedance system
Lower Power Consumption< 2W
Power Supply +3.3V
Low Near-End Crosstalk
Fully compatible with IEEE802.3ba and Infiniband QDR specifications
Temperature Range -40 to 85°C
All-metal housing for superior EMI performance
Precision process control for minimization of pair-to-pair skew
EEPROM for cable signature & system communications
Compliant QSFP MSA specifications
RoHS6 compliant
Applications
Networked storage systems
External storage systems
Data Center networking
Hubs, Switches, Routers, Servers
Description 40G QSFP+ copper direct-attach cables are suitable for very short distances and offer a highly cost-effective way to establish a 40-Gigabit link between QSFP+ ports of QSFP+ switches within racks and across adjacent racks. These cables are used for 40GbE and Infniband standards, to maximize performance. QSFP+ are designed to meet emerging data center and high performance computing application needs for a high density cabling interconnect system capable of delivering an aggregate data bandwidth of 40Gb/s. This interconnect system is fully compliant with existing industry standard specifications such as the QSFP MSA and IBTA (InfiniBand Trade Association). The QSFP+ cables support the bandwidth transmission requirements as defined by IEEE 802.3ba (40 Gb/s) and Infiniband QDR (4x10 Gb/s per channel) specifications. 1
Datasheet
Specifications Table 1 - Absolute Maximum Ratings Parameter
Symbol
Min
Storage Temperature
Tst
Max
Units
-40
125
°C
RS
-
85
%
Operating Case Temperature
Topc
-40
85
°C
Supply Voltage
VCC3
-0.3
3.6
V
Voltage on LVTTL Input
Vilvttl
-0.3
Relative Humidity (non-condensation)
Typ
3.3
VCC3
Note
Note1
V
+0.2
Notes: Note1: Stress or conditions exceed the above range may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions above those listed in the operational sections of this specification is not applied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Table 2 - Normal operating condition Parameter
Symbol
Min
Operating Case Temperature
Topc
Relative Humidity (non-condensation)
Typ
Max
Units
-40
85
°C
RS
-
85
%
Supply Voltage
VCC3
3.135
3.465
V
Power Supply Current
ICC3
750
-
mA
Total Power Consumption
Pd
-
2.0
W
3.3
Table 3 - Regulatory Compliance Feature
Standard MIL-STD-883G
Electrostatic Discharge (ESD) to the Electrical Pins
Method 3015.7
Performance Class 1C (>1000 V)
EN 55024:1998+A1+A2 Electrostatic Discharge to the enclosure
IEC-61000-4-2
Compatible with standards
GR-1089-CORE Compatible with standards Noise frequency range: FCC Part 15 Class B
30MHz to 6GHz. Good system
EN55022:2006
EMI design practice required
CISPR 22B :2006
to achieve Class B margins.
VCCI Class B
System margins are dependent on
Electromagnetic Interference (EMI)
customer host board and chassis design. 2
Datasheet Compatible with standards. 1KHz sine-wave, 80% AM, Immunity
EN 55024:1998+A1+A2
from 80MHz to 1GHz. No
IEC 61000-4-3
effect on transmitter/receiver performance is detectable between these limits.
FDA 21CFR 1040.10 and Laser Eye Safety
1040.11 EN (IEC) 60825-1:2007 EN (IEC) 60825-2:2004+A1 UL and CUL
Component Recognition
RoHS6
EN60950-1:2006 2002/95/EC 4.1&4.2 2005/747/EC 5&7&13
CDRH compliant and Class I laser product. TüV Certificate No. 50135086 UL file E317337 TüV Certificate No. 50135086 (CB scheme ) Compliant with standards*note2
Notes: Note2: For update of the equipments and strict control of raw materials, Fiberstore has the ability to supply the customized products since Jan 1th, 2007, which meet the requirements of RoHS6 (Restrictions on use of certain Hazardous Substances) of European Union. In light of item 5 in RoHS exemption list of RoHS Directive 2002/95/EC, Item 5: Lead in glass of cathode ray tubes, electronic components and fluorescent tubes. In light of item 13 in RoHS exemption list of RoHS Directive 2005/747/EC, Item13: Lead and cadmium in optical and filter glass. The three exemptions are being concerned for Fiberstore’s transceivers, because Fiberstore’s transceivers use glass, which may contain Pb, for components such as lenses, windows, isolators, and other electronic components.
3
Datasheet
Pin Assignments and Descriptions
Pin No.
Logic
1
Symbol
Name/Description
Note
GND
Ground
3
2
CML-I
Tx2n
Transmitter Inverted Data Input
3
CML-I
Tx2p
Transmitter Non-Inverted Data output
GND
Ground
4 5
CML-I
Tx4n
Transmitter Inverted Data Input
6
CML-I
Tx4p
Transmitter Non-Inverted Data output
GND
Ground
7 8
LVTLL-I
ModSelL
Module Select
9
LVTLL-I
ResetL
Module Reset
Vcc Rx
﹢3.3V Power Supply Receiver
SCL
2-Wire Serial Interface Clock
10 11
LVCMOS-I/O
4
3
3
4
Datasheet 12
LVCMOS-I/O
13
SDA
2-Wire Serial Interface Data
GND
Ground
14
CML-O
Rx3p
Receiver Non-Inverted Data Output
15
CMLO
Rx3n
Receiver Inverted Data Output
GND
Ground
16
3
17
CMLO
Rx1p
Receiver Non-Inverted Data Output
18
CMLO
Rx1n
Receiver Inverted Data Output
19
GND
Ground
3
20
GND
Ground
3
21
CMLO
Rx2n
Receiver Inverted Data Output
22
CMLO
Rx2p
Receiver Non-Inverted Data Output
GND
Ground
3 3
23 24
CMLO
Rx4n
Receiver Inverted Data Output
25
CMLO
Rx4p
Receiver Non-Inverted Data Output
GND
Ground
26
3
27
LVTTLO
ModPrsL
Module Present
28
LVTTLO
IntL
Interrupt
29
Vcc Tx
+3.3 V Power Supply transmitter
4
30
Vcc1
+3.3 V Power Supply
4
LPMode
Low Power Mode
GND
Ground
31
LVTTLI
32 33
CMLI
Tx3p
Transmitter Non-Inverted Data Input
34
CMLI
Tx3n
Transmitter Inverted Data Output
GND
Ground
Tx1p
Transmitter Non-Inverted Data Input
35 36
CMLI
5
3
3
Datasheet 37 38
CMLI
Tx1n
Transmitter Inverted Data Output
GND
Ground
3
Notes: Note3: GND is the symbol for signal and supply (power) common for QSFP modules. All are common within the QSFP module and all module voltages are referenced to this potential otherwise noted. Connect these directly to the host board signal common ground plane. Note4: Vcc Rx, Vcc1 and Vcc Tx are the receiver and transmitter power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown below. Vcc Rx, Vcc1 and Vcc Tx may be internally connected within the QSFP transceiver module in any combination. The connector pins are each rated for a maximum current of 500mA.
Recommended power supply filtering Example A typical host board mechanical layout for attaching the QSFP transceiver is presented below. The recommended host electrical connector should be a 38-pin IPASS right angle connector assembly (example: Tyco PN: 1761987-9) and the cage assembly should be QSFP single cage (example: Tyco PN: 1888617-1).
6
Datasheet
Recommended PCB layout A typical host board mechanical layout for attaching the QSFP transceiver is presented below. The recommended host electrical connector should be a 38-pin IPASS right angle connector assembly (example: Tyco PN: 1761987-9) and the cage assembly should be QSFP single cage (example: Tyco PN: 1888617-1).
7
Datasheet
Mechanical Specifications
Ordering Information
Part No.
Data Rate (Gbps)
Length (m)
AWG
Passive / Active
Temp. Range (°C)
Package
QQ-PC-30-0.5-xx
40
0.5
30
Passive
-40 to +85
QSFP+ to QSFP+
QQ-PC-30-1-xx
40
1
30
Passive
-40 to +85
QSFP+ to QSFP+
QQ-PC-30-2-xx
40
2
30
Passive
-40 to +85
QSFP+ to QSFP+
QQ-PC-30-3-xx
40
3
30
Passive
-40 to +85
QSFP+ to QSFP+
Notes: xx means compatible brand. (For example: CO= Cisco, JU=Juniper, FD=Foundry, EX=Extreme, NE=Netgear.)
8
Datasheet
FiberStore U.S.
FiberStore Hong Kong
FiberStore China
X205 4181 129th Place SE, Bellevue
1220 Tung Chun Commercial Centre,
5D Intelligent Tower,
98006, WA,
438-444 Shanghai Street, Kowloon,
Fumin Road Futian,
United States
HongKong
Shenzhen 518045, GuangDong,
Tel: +1 (206) 453 0158
Tel: (852) 8120 3582
China
Fax: +1 (425) 505 2761
Fax: (852) 8120 3582
Tel: +86 (755) 8300 3611 Fax: +86 (755) 8326 9395
Addresses, phone number and fax number also have been listed at www.fiberstore.com. Please e-mail us at
[email protected] or call us for assistance. All statements, technical information, and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact FiberStore for more information.
9