10520_fire Extinguishers-cabinets

   EMBED


Share

Transcript

THEODORE PAYNE FOUNDATION SUN VALLEY, CALIFORNIA SECTION 10520 FIRE EXTINGUISHERS, CABINETS, AND ACCESSORIES 1.00 GENERAL 1.01 SECTION INCLUDES: A. Fire extinguishers. B. Fire extinguisher cabinets or wall mount brackets. C. Accessories. 1.02 RELATED SECTIONS A. Section 06100 - Rough Carpentry: Wood framed openings, blocking, and shims. B. Section 09260-Gypsum Board Assemblies: Roughed-in wall openings. C. Section 09900 - Paints and Coatings: Field paint finish. 1.03 REFERENCES A. NFPA 10 - Standard for Portable Fire Extinguishers; National Fire Protection Association; 1998. 1.04 PERFORMANCE REQUIREMENTS A. Conform to NFPA 10. 1.05 SUBMITTALS A. See Section 01300 - Administrative Requirements, for submittal procedures. B. Shop Drawings: Indicate cabinet physical dimensions, rough-in measurements for recessed cabinets, and location. C. Product Data: Provide extinguisher operational features. 2.00 PRODUCTS 2.01 MANUFACTURERS A. Fire Extinguishers, Cabinets and Accessories: 1. 2. 3. 4. JL Industries, Inc. Larsen's Manufacturing Co. Potter-Roemer. Substitutions: See Section 01600 - Product Requirements. ____________________________________________________________________________________________ ISSUED FOR BID, JULY 29, 2013 SECTION 10520 Page 1 THEODORE PAYNE FOUNDATION SUN VALLEY, CALIFORNIA 2.02 FIRE EXTINGUISHERS A. Dry Chemical Type: Stainless steel tank, with pressure gage. 1. 2. 3. Class 2A10: B:C. Size 5 pound. Size and classification as approved by local Fire Authorities. Verify prior to installation. 2.03 FIRE EXTINGUISHER CABINETS A. Metal: Formed primed steel sheet; 0.036 inch thick base metal. B. Cabinet Configuration: Surface type at masonry walls; where mounted on frame wall with sufficient depth, provide semi-recessed type with trim returned to wall. Wall brackets only in service areas. 1. Form cabinet enclosure with right angle inside corners and seams. Form perimeter trim and door stiles. C. Door: 0.036 inch thick, reinforced for flatness and rigidity; latch. Hinge doors for 180 degree opening with two butt hinge. Provide nylon catch. D. Door Glazing: Glass, clear, 1/8 inch thick float. Set in resilient channel gasket glazing. E. Cabinet Mounting Hardware: Appropriate to cabinet. Pre-drill for anchors. F. Weld, fill, and grind components smooth. G. Finish of Cabinet Exterior Trim and Door: Primed for field paint finish. H. Finish of Cabinet Interior: White enamel. 2.04 ACCESSORIES A. Extinguisher Brackets: Formed steel, chrome-plated. 3.00 EXECUTION 3.01 EXAMINATION A. Verify existing conditions before starting work. B. Verify rough openings for cabinet are correctly sized and located. 3.02 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Install cabinets plumb and level in wall openings, 54 inches from finished floor to top of cabinet (or extinguisher at wall bracket mount). ____________________________________________________________________________________________ ISSUED FOR BID, JULY 29, 2013 SECTION 10520 Page 2 THEODORE PAYNE FOUNDATION SUN VALLEY, CALIFORNIA C. Secure rigidly in place. D. Place extinguishers in cabinets and on wall brackets. 3.03 SCHEDULES A. Corridors: Placed 75 feet apart maximum. Semi-recessed mounting. Verify locations with local Fire Jurisdiction before framing corridors for cabinets. B. Elevator Equipment Rooms 3-151 and 4-181: 1 required each room, wall bracket mounting. C. Community Room 3-146 and Kitchen 3-147: 1 required each room, semi-recessed mounting. D. Work Room 1-104: 1 required, semi-recessed mounting. E. Mechanical Room 3-171: 1 required, wall bracket mounting. F. Janitor Rooms 3-152 and 3-251: 1 required each room, wall bracket mounting. ____________________________________________________________________________________________ ISSUED FOR BID, JULY 29, 2013 SECTION 10520 Page 3