Preview only show first 10 pages with watermark. For full document please download

1069673a_011007_front [converted]

   EMBED


Share

Transcript

Purge the Guns 1. Press on the keypad to navigate from the System Screens to the Gun screens (1-8). 2. Press Screen Symbol Information i+ Information screen symbols V+ Version screen symbol. Contrast adjust screen symbol. on the keypad to purge an individual gun. NOTE: The Flush operation functions the same as Purge with the exception that once the Flush operation is started, you can navigate through the screens without effecting the gun or guns being flushed. To terminate Flush the operation, press Purge again. NOTE: The Hammering operation is used for clearing clogged or partially clogged nozzle, especially in liquid adhesive guns. The gun driver can be programmed to activate the hammering function using the System Setting screen. Password screen symbol. Password assignment screen symbol. Refer to manual. User's Guide System status screen symbols System OK symbol. Gun Alarm. LogiComm Gun Driver ® Alarm symbols: GUN # OPEN (the gun number will be included) When the purge or flush function is activated and hammering is enabled, the gun output will turn On/Off at high speed, cycling the gun on and off for as long as the purge of flush function is active. GUN # SHORT (the gun number will be included) Part 1087838A Driver SHORT (gun output channel disabled and latched off) Fault symbols: Control board fault symbol is accompanied by one of the following text: IO/IF FAULT (trigger interface) PS/IF FAULT (power supply interface) PWR FAIL (power fail) PS CFG FLT (power supply configuration fault) DRV CFG FLT (driver configuration fault) PS 24V FLT (main 24V power supply disabled in this condition) System settings screen symbols Symbols for purging or flushing a gun. Gun flush. Gun purge. Symbols for turning the hammering On or Off. Hammering On. Hammering Off. Symbols for turning the remote purge On or Off. Remote purge On. Remote purge Off. 1 - 8 Gun screen symbols (1-8) Symbol for enabling or disabling a gun. Enable a gun. Disable a gun. Gun Settings Screen Symbols (1-8) Gun type selection symbol. Trigger (1-8) assignment symbol. / Trigger polarity selection symbol. Bead or Dot mode selection symbol. Gun driver output waveform setup symbol. NORDSON CORPORATION DULUTH, GEORGIA www.nordson.com USA I 2 1 i+ V+ : VERSIONS CONTRAST PASSWORD RESET ALL : 1 2 5 6 2 1 1 SYSTEM OK 3 4 7 II 3 : : DISABLE : SETTINGS A B B C C ENABLE or DISABLE B 1 a : : : : ON or OFF b : : : : b 1 ON or OFF NONE 1 2 3 2 4 DISABLE : SETTINGS ... B 2 a Button Name Function Next and Previous button Navigates horizontally through each screen level. NOTE: In the Gun setup screens, you can move horizontally from one gun to the next and wrap back around to Gun #1 from Gun #8. A ENABLE or DISABLE PURGE or FLUSH : ... A A A DISABLE : SETTINGS Keypad Navigation Buttons Button Type 8 2 PURGE OFF OFF 8 4 or 8 : : : : ... b 1 2 3 4 Tab button Navigates to the next field in the current menu screen. NOTE: Most menu items are arranged vertically on the screen. The currently selected item will always be highlighted. NONE Enter button Navigates from the upper level screens to the lower level screens, and from the lower level screens back to the upper level screens. Up and Down button 1. Toggles: - Gun hammering On/Off - Remote purge On or Off. - Gun enable/disable - Gun purge/flush - Trigger polarity selection B 8 a NONE ENABLE or DISABLE 8 1 ... 2 3 4 5 5 5 NO YES 2 5.0 ms Legend I - System Screens 1. Information Screens A: Versions of the CPU, software, drivers, and power supply. 2. System Status Screen System OK or Fault message. 3. System Settings Screens: B: Screen contrast setup. A: Purge or Flush the gun. C: Password setup. B: Gun set to hammering On or Off. D: Reset All. CAUTION: Refer to manual. d II - Gun Screens C: Gun set to remote purge On or Off. Select a Gun Type Individual Gun Screens (1-8) A: Enable or disable guns. B: Gun settings screens: a: Gun type selection (1-8). b: Trigger assignment screen (1-8). c: Bead or Dot mode selection (1-8). If Dot mode is selected, view the Dot time screen. d: Gun driver output waveform setup screens. 1 : HD HD MODE 23.40 8.00 ms : 1 2 I MODE 1.80 A 5.0 ms d : HD HD MODE 23.40 8.00 ms Purge or Flush button 8 ... or : 2 0.80 ms For additional details on 1.80 A : HD HD MODE 23.40 8.00 ms I MODE 8 : I MODE LED Type on the keypad to navigate to Settings. 3. Press screen. on the keypad to view the Gun Settings 2. Press on the keypad to select from triggers 1-4. The selected trigger is highlighted. on the keypad 0.50 A 1.80 A 0.50 A LED Color TRIGGER Green Illuminates each time the trigger input activates. POWER Green Illuminates to display that the system is ready for operation. FAULT Red Illuminates to display a fault. NOTE: When a fault condition occurs, the gun is inoperable. ALARM Yellow or Gun Output Waveform parameters, refer to the LogiComm Gun Driver manual. 1. While in the Gun Settings screen, press navigate to Bead or Dot mode. on the keypad to to select a different trigger. a. Press 4. Press or b. Press on the keypad to increase the dot time, or press to decrease the dot time. polarity ( / ). c. Press on the keypad to exit the Trigger Assignment on the keypad to view the Dot Time screen. to return to the Gun Settings screen. NOTE: There is no set up for Bead mode. The gun output will follow the trigger that was assigned to it. Issued 5/08 Original copyright date 2007. Nordson and the Nordson logo are registered trademarks of Nordson Corporation. Illuminates to display the following conditions: gun short, gun open, disconnected ribbon cables. NOTE: The LED activates whenever there is a condition that requires user/remote notification. NOTE: When an alarm condition occurs, Nordson Corporation recommends diagnosing and correcting the cause of the fault as soon as practical. 2. Press or on the keypad to select Bead or Dot mode. If you have selected Dot mode, perform the following steps: 3. Press on the keypad to select trigger Function LED Name Select Bead or Dot Mode 2. Press 5. Press screen. NOTE : Parameter changes take effect immediately. However, the parameter changes do not get saved until the user leaves the field. 0.80 ms Also refer to the LogiComm Gun Driver manual for details on how to install, program, and operate the gun driver. Assign a Trigger Purges an individual gun when selected. LED Information or 0.80 ms 0.50 A 1. In the Gun Settings screen, press to navigate to Trigger Assignment. NOTE: Once you select a gun type, the optimum gun parameters for the selected gun is downloaded to the gun driver. d or 1. Press on the keypad to navigate from the System Screens (I) to the Gun screens (II). 4. Press or on the keypad to scroll through the types of guns to select. 5.0 ms 3. Adjusts the numeric values for the: - Dot bead settings - Gun parameter settings 8 ... % X 2. Selects a gun type. c % D c 1 % c GUN OUTPUTS Green Illuminates each time the gun activates.