RoHS Compliant 10Gb/s 1550nm XFP 40km Transceiver RTXX0SER Applications    Features              Description RoHS compliant 10Gb/s optical links Compliant with XFP MSA Support multi protocol from 9.9Gb/s to 11.1Gb/s Transmission distance of 40km over single mode fiber 1550nm EML laser transmitter LC duplex connector 2-wire interface for management and diagnostic monitor Hot pluggable 30 pin connector XFI electrical interface with AC coupling Power supply voltages : +3.3V, +5V Power dissipation: <3.5W Three optional operating temperature ranges : Option ST : 0°C to 70°C Option ET : -5°C to 85°C Option IT : -40°C to 85°C www.oesolution.com SONET OC-192 IR-2 / SDH S-64.2b 10GBASE-ER/EW Ethernet 40km 10G FC OE Solutions’ XFP transceivers are designed to be compatible with the XFP 30pin Multi-Source Agreement (MSA). The high performance cooled 1550nm EML transmitter and high sensitivity PIN receiver provide superior performance for SONET/SDH and Ethernet applications up to 40km optical links. Advanced Digital Diagnostics functions are available via the 2-wire serial bus specified in the XFP MSA. The transmitter and receiver features ac-coupled differential data inputs and outputs, and an LVTTL for Tx disable input and Tx fault output. Software TX disable is also implemented. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output. 1 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 1. Absolute Maximum Ratings Parameter Symbol Min. Typ. Max. Unit Notes Vcc3_max 0 - 4.0 V - Vcc5_max 0 - 6.0 V - Operating Case Temperature Top -40 - 85 °C - Storage Temperature Tst -40 - 85 °C - Symbol Min. Typ. Max. Unit Notes B 9.9 10.3 11.1 Gb/s - - - Absolute Supply Voltage 2. General Operating Conditions Parameter Bit Rate Bit Error Rate BER - - Maximum Transmission Distance Dmax - 40 - km - Vcc3 3.135 - 3.465 V - Vcc5 4.75 - 5.25 V - Top -40 - 85 °C 1,2 Power supply current ICC3 - 200 500 mA 3 Power supply current ICC5 - 300 mA - Operating Voltage Operating Case Temperature Notes : 10 -12 1. Measured on bottom side front center of XFP module 2. There are three options of operating maximum temperature: Option ST: standard temperature from 0oC to 70oC, Option ET: extended temperature from -5oC to 85oC,Option IT: extended temperature from -40oC to 85oC 3. Powers TEC; current draw depends on temperature 3. Electrical Specifications 3.1 Module Electrical Specifications (Over Operating Case Temperature and Power Supply Range) Parameter Symbol Min. Typ. Max. Unit Notes Vol 0.0 - 0.4 V - Voh Vcc-0.5 - Vcc+0.3 V 1 Vil -0.3 - 0.8 - - Vih 2.0 - Vcc3+0.3 - - Interrupt Assert Delay Interrupt_on - - 200 ms - Interrupt Negate Delay Interrupt_off - - 500 µs - Mod_NR Assert / Negate Delay - - - 1 ms - P-Down Reset Time - 10 - - µs - XFP Interrupt, Mod_NR P_Down/RST Note : 1. Vcc is the voltage of host board 2 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 3.2 Transmitter Electrical Specifications (Over Operating Case Temperature and Power Supply Range) Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes Differential Input Impedance Rin - 100 - Ω - Differential Data Input Swing Vin,pp 150 - 1000 mVp-p - Tx Disable Voltage Vd 2.0 - - Vcc+0.3 - Tx Enable Voltage Ven 0 - 0.8 V - Tx Disable Assert Time T_off - - 10 µs - Tx Enable Assert Time T_on - - 2 ms - T_start - - 300 ms - Initialization Time 3.3. Receiver Electrical Specifications (Over Operating Case Temperature and Power Supply Range) Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes B 9.9 10.3 11.1 GBd - Differential Output Impedance Rout - 100 - Ω - Differential Data Output Swing Vout 300 600 750 mVp-p - Data Output Rise/Fall Time tr/tf - - 45 ps - LOS Output High Voltage Vlosh Vcc-0.5 LOS Output Low Voltage Vlosl - - 0.5 V T_los_onoff - - 100 µs Data Rate LOS Assert/Deassert Time Delay Note : Vcc-0.3 1 - 1. Vcc is the voltage of host board 3 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 4. Optical Specifications 4.1 Transmitter Optical Specifications (Over Operating Case Temperature and Power Supply Range) Optical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes Optical Power Pout -1 - 2 dBm 1 Optical Modulation Amplitude (10GE) OMA -1.7 - - dBm - ER 8.2 - - dB - λ 1530 1550 1565 nm - SMSR 30 - - dB - ∆λ - - 1 nm - Pout-off - - -30 dBm - RIN12OMA - - -130 dB/Hz - Optical Return Loss Tolerance - - - 27 dB - Optical Path Penalty (Dispersion: 800ps/nm) - - - 2 dB - Optical Extinction Ratio Optical Wavelength Side Mode Suppression Ratio Spectral Width Optical power of OFF transmitter Relative Intensity Noise Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-825 standards. They must be operated under specified operating conditions. 4.2. Receiver Optical Specifications (Over Operating Case Temperature and Power Supply Range) Optical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes λ 1270 1310 1600 nm - RSENS1 - -15.8 dBm 1 RSENS2 - - -11.3 dBm 1 Pol 0.5 - - dBm - - - - -27 dB - LOS Assert LOS_A -28 - - dBm - LOS De-assert LOS_D - - -18 dBm - LOS Hysteresis - - 2 5 dB - Optical Wavelength Receiver [email protected]/s Stressed Receiver Sensitivity (OMA)@10.3125Gb/s Maximum Input Power Receiver Reflectance Notes : 1. Measured with a PRBS of 231-1 at 1 x 10-12 BER and 8.2dB extinction ratio 4 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 5. Pin Descriptions XFP Transceiver Electrical Pad Layout 5 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications Pin Descriptions (continued) Pin Logic Symbol Description Notes 1 2 - GND VEE5 1 3 LVTTL-I Mod_DeSel 4 LVTTL-O 5 6 7 LVTTL-I - TX_DIS VCC5 GND Module Ground Not required Module De-select; When held low allows module to respond to 2-wire serial interface Interrupt; Indicates presence of an important condition which can be read over the 2-wire serial interface Transmitter Disable; Turns off transmitter laser output +5V Power Supply Module Ground 8 - VCC3 +3.3V Power Supply 9 10 LVTTL-I/O VCC3 SCL +3.3V Power Supply 2-Wire Serial Interface Clock 2 11 LVTTL-I/O SDA 2-Wire Serial Interface Data Line 2 12 13 14 LVTTL-O LVTTL-O LVTTL-O Mod_Abs Mod_NR RX_LOS Indicates Module is not present. Grounded in the Module Module Not Ready; Indicating Module Operational Fault Receiver Loss Of Signal Indicator 2 2 2 15 - GND Module Ground 1 16 17 18 CML-O CML-O GND RDRD+ Module Ground Receiver Inverted Data Output, AC coupled in the module Receiver Non-Inverted Data Output, AC coupled in the module 1 19 20 - GND VCC2 1 3 21 LVTTL-I P_Down/RST Module Ground Not required Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire serial interface must be functional in the low power mode. 22 23 24 25 26 27 28 29 30 Notes : PECL-I PECL-I CML-I CML-I - Interrupt VCC2 GND RefCLK+ RefCLKGND GND TDTD+ GND Reset; The falling edge initiates a complete reset of the module including the 2wire serial interface, equivalent to a power cycle. No use Module Ground Not required Not required Module Ground Module Ground Transmitter Inverted Data Input, AC coupled in the module Transmitter Non-Inverted Data Input, AC coupled in the module Module Ground 2 1 3 1 1 1 1 1. Module ground pins Gnd are isolated from the module case and chassis ground within the module. 2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board. 6 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 6. Outline Drawings Dimensions are in millimeters 7 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 7. PCB layout and Bezel recommendation Dimensions are in millimeters XFP Host Board Mechanical Layout 8 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications PCB layout and Bezel recommendation (continued) XFP Host Board Mechanical Layout Recommended Single Sided Bezel Design 9 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 8. SFP+ Block Diagram, Power Supply Information and Host Board Interface 8.1 XFP Block Diagram and Host Board Interface Pin 5 Pin 29 Tx Disable TD+ TOSA Laser Zin diff.= 100Ω 100Ω TD- Pin 28 Pin 10 Management processor SCL EEPROM Pin 11 SDA Pin 17 RD- ROSA Zout = 50Ω Post amp. each arm RD+ Pin 18 Pin 8, 9 VCC3 Pin 6 VCC5 Pin 2 VEE5 (Not used) Pin 22 VCC2 (Not used) Pin 24,25 Mod_DeSel, P_Down/RST Pin 3, 21 Module Pin 1, 7, 15, 16, GND 19, 23, 26, 27 VCC3 R RefCLK+/- (Not used) Interrupt, RX_LOS Pin 4,14 R Mod_Abs, Mod_NR Pin 12, 13 SCL. SDA R Pin 10, 11 R= 4.7k ~ 10kΩ Note 1: Host board output device circuit in the transmitter side and host board input device circuit in the receiver should be carefully designed to meet 100ohm differential impedance matching. Also necessary is the dc bias circuit of each input and output by taking into account of ac coupling of data input ant output of XFP module. For the interface of host board devices, it is recommended to refer to the device vendor’s data sheet. 10 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 8.2 Recommended Host Board Supply Filtering Network 4.7µH VCC3 Vcc3 0.1µF 22µF 0.1µF 4.7µH Vcc5 VCC5 0.1µ XFP Module 0.1µF 22µF HOST BOARD 9. Digital Diagnostic Monitoring and Serial ID Operation Serial ID and Map: page A0h Address 0 HEX 06 1 00 2 3 4 5 6 7 8 9 10-17 18 19 20 21 22 23 24 25 26 27 varies varies varies varies varies varies varies varies 00 EA 60 3A 98 D6 D8 4E 20 4D F1 Name of Fields Identifier Signal Conditioner Control Field [7-4] Data Rate Control [2] Lineside Loopback [1] XFI Loopback [0] Signal Conditioner Control Temp High Alarm MSB Temp High Alarm LSB Temp Low Alarm MSB Temp Low Alarm LSB Temp High Warning MSB Temp High Warning LSB Temp Low Warning MSB Temp Low Warning LSB Reserved A/D Flag Thresholds(10-17) Bias High Alarm MSB Bias High Alarm LSB Bias Low Alarm MSB Bias Low Alarm LSB Bias High Warning MSB Bias High Warning LSB Bias Low Warning MSB Bias Low Warning LSB TX Power High Alarm MSB TX Power High Alarm LSB 11 Description [06h] XFP Signal Conditioner Control Field Data Rate Control(01[7:4]) = 9.50 Gb/s [0b] Normal Operation [0b] Normal Operation [0b] Normal Asynchronous REFCLK mode ST: 100.00 [ ], ET and IT: 120.00 [ ] ℃ ℃ ℃ ℃ ℃ ST: -5.00 [ ], ET: -10.00 [ ], IT: -45.00 [ ], ℃ ℃] ST: 0.00 [℃], ET: -5.00 [℃], IT: -40.00 [℃], ST: 90.00 [ ], ET and IT: 110.00 [ 120.00 [mA] 30.00 [mA] 110.0 [mA] 40.0 [mA] 3.0 [dBm] Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 13 94 3D E9 18 A6 31 2D 00 9E 2B D4 00 C8 8C A0 75 30 88 B8 79 18 32 00 19 00 2D 00 1E 00 58 00 59 00 60-69 70 71 72 73 74 75 76 77 78 79 00 00 00 00 00 00 00 80 00 00 00 TX Power Low Alarm MSB TX Power Low Alarm LSB TX Power High Warning MSB TX Power High Warning LSB TX Power Low Warning MSB TX Power Low Warning LSB RX Power High Alarm MSB RX Power High Alarm LSB RX Power Low Alarm MSB RX Power Low Alarm LSB RX Power High Warning MSB RX Power High Warning LSB RX Power Low Warning MSB RX Power Low Warning LSB AUX 1 High Alarm MSB (power supply) AUX 1 High Alarm LSB (power supply) AUX 1 Low Alarm MSB (power supply) AUX 1 Low Alarm LSB (power supply) AUX 1 High Warning MSB (power supply) AUX 1 High Warning LSB (power supply) AUX 1 Low Warning MSB (power supply) AUX 1 Low Warning LSB (power supply) AUX 2 High Alarm MSB (Laser Temp) AUX 2 High Alarm LSB (Laser Temp) AUX 2 Low Alarm MSB (Laser Temp) AUX 2 Low Alarm LSB (Laser Temp) AUX 2 High Warning MSB (Laser Temp) AUX 2 High Warning LSB (Laser Temp) AUX 2 Low Warning MSB (Laser Temp) AUX 2 Low Warning LSB (Laser Temp) VPS Fields [7-4] Lowest Voltage Supported with an Operational LV Regulator [3-0] Voltage Supplied on the VCC2 Pins VPS Fields [7-4] Voltage Supported with a Bypassed Regulator [0] Regulator bypass mode -3.0 [dBm] 2.0 [dBm] -2.0 [dBm] 1.0 [dBm] -18.0 [dBm] 0.5 [dBm] -17.0 [dBm] 3.6 [V] 3.0 [V] 3.5 [V] 3.1 [V] ℃ 25.00 [℃] 45.00 [℃] 30.00 [℃] 50.00 [ ] Not Supported Not Supported Acceptable BER Actual BER Not Supported Not Supported Wavelength Set MSB(72-73) Not Supported Wavelength Error LSB(74-75) Not Supported Amplitude Adjustment Phase Adjustment 0.00 [%] Not Supported Reserved(78-79) 12 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 80 xx 81 xx 82 xx 83 xx 84 xx 85 xx 86 xx Latched Interrupt Flag Fields(80) [7] L-Temp High Alarm [6] L-Temp Low Alarm [3] L-TX Bias High Alarm [2] L-TX Bias Low Alarm [1] L-TX Power High Alarm [0] L-TX Power Low Alarm Latched Interrupt Flag Fields(81) [7] L-RX Power High Alarm [6] L-RX Power Low Alarm [5] L-AUX 1 High Alarm [4] L-AUX 1 Low Alarm [3] L-AUX 2 High Alarm [2] L-AUX 2 Low Alarm Latched Interrupt Flag Fields(82) [7] L-Temp High Warning [6] L-Temp Low Warning [3] L-TX Bias High Warning [2] L-TX Bias Low Warning [1] L-TX Power High Warning [0] L-TX Power Low Warning Latched Interrupt Flag Fields(83) [7] L-RX Power High Warning [6] L-RX Power Low Warning [5] L-AUX 1 High Warning [4] L-AUX 1 Low Warning [3] L-AUX 2 High Warning [2] L-AUX 2 Low Warning Latched Interrupt Flag Fields(84) [7] L-TX_NR [6] L-TX_Fault [5] L-TX CDR [4] L-RX_NR [3] L-RX_LOS [2] L-RX CDR [1] L-MOD_NR [0] L-Reset Latched Interrupt Flag Fields(85) [7] L-APD Supply Fault [6] L-TEC Fault [5] L-Wavelength Unlocked Latched Interrupt Flag Fields(86) [7] L-VCC5 High Alarm [6] L-VCC5 Low Alarm [5] L-VCC3 High Alarm [4] L-VCC3 Low Alarm [3] L-VCC2 High Alarm [2] L-VCC2 Low Alarm [1] L-Vee5 High Alarm [0] L-Vee5 Low Alarm 13 Varies Varies Varies Varies Varies Varies Varies Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 87 xx 88 00 89 00 90 00 91 00 92 00 93 00 Latched Interrupt Flag Fields(87) [7] L-VCC5 High Warning [6] L-VCC5 Low Warning [5] L-VCC3 High Warning [4] L-VCC3 Low Warning [3] L-VCC2 High Warning [2] L-VCC2 Low Warning [1] L-Vee5 High Warning [0] L-Vee5 Low Warning Interrupt Masking Bits(88) [7] M-Temp High Alarm [6] M-Temp Low Alarm [3] M-TX Bias High Alarm [2] M-TX Bias Low Alarm [1] M-TX Power High Alarm [0] M-TX Power Low Alarm Interrupt Masking Bits(89) [7] M-RX Power High Alarm [6] M-RX Power Low Alarm [5] M-AUX 1 High Alarm [4] M-AUX 1 Low Alarm [3] M-AUX 2 High Alarm [2] M-AUX 2 Low Alarm Interrupt Masking Bits(90) [7] M-Temp High Warning [6] M-Temp Low Warning [3] M-TX Bias High Warning [2] M-TX Bias Low Warning [1] M-TX Pow.High Warning [0] M-TX Pow.Low Warning Interrupt Masking Bits(91) [7] M-RX Pow.High Warning [6] M-RX Pow.Low Warning [5] M-AUX 1 High Warning [4] M-AUX 1 Low Warning [3] M-AUX 2 High Warning [2] M-AUX 2 Low Warning Interrupt Masking Bits(92) [7] M-TX_NR [6] M-TX_Fault [5] M-TX CDR not Locked [4] M-RX_NR [3] M-RX_LOS [2] M-RX CDR not Locked [1] M-MOD_NR [0] M-Reset Complete Interrupt Masking Bits(93) [7] M-APD Supply Fault [6] M-TEC Fault [5] M-Wavelength Unlocked 14 Varies Varies Varies Varies Varies Varies Varies Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 94 00 95 00 96 97 98-99 100 101 102 103 104 105 106 107 108 109 xx xx 00 xx xx xx xx xx xx xx xx xx xx 110 xx 111 xx 112-117 00 118 00 119-126 127 128 00 01 06 Interrupt Masking Bits(94) [7] M-VCC5 High Alarm [6] M-VCC5 Low Alarm [5] M-VCC3 High Alarm [4] M-VCC3 Low Alarm [3] M-VCC2 High Alarm [2] M-VCC2 Low Alarm [1] M-Vee5 High Alarm [0] M-Vee5 Low Alarm Interrupt Masking Bits(95) [7] M-VCC5 High Warning [6] M-VCC5 Low Warning [5] M-VCC3 High Warning [4] M-VCC3 Low Warning [3] M-VCC2 High Warning [2] M-VCC2 Low Warning [1] M-Vee5 High Warning [0] M-Vee5 Low Warning Temperature MSB (Module Temp) Temperature LSB (Module Temp) Reserved(98-99) TX Bias MSB TX Bias LSB TX Power MSB TX Power LSB RX Power MSB RX Power LSB AUX 1 MSB AUX 1 LSB AUX 2 MSB AUX 2 LSB Control/Status Bits [7] TX Disable State [6] Soft TX Disable [5] MOD_NR State [4] P_Down State [3] Soft P_Down [2] Interrupt [1] RX_LOS [0] Data_Not_Ready Control/Status Bits [7] TX_NR State [6] TX_Fault [5] TX_CDR [4] RX_NR [3] RX_CDR Pcket Error Checking [0] Error Checking Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies [0b] Disable Packet Error Checking Table Select Identifier [06h] XFP 15 Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications [10b] Power Level 3 Module (3.5W max.power dissipation.) [0] Module with CDR function [1] TX Ref Clock Input Not Required [1] CLEI code present in Table 02h 129 98 Extended Identifier 130 07 Connector 131 22 Gigabit Ethernet Compliance 132 133 134 135 00 00 00 00 Gigabit Fibre Channel Compliance Gigabit Copper Links Lower Speed Links SONET/SDH Codes -Interconnect 136 20 SONET/SDH Codes Short Haul 137 138 00 00 SONET/SDH Codes Long Haul SONET/SDH Codes Very Long Haul 139 10 Encoding [4] NRZ 140 141 142 143 144 145 146 63 6F 28 00 00 00 00 BR,MINIMUM BR,MAXIMUM LENGTH (Km) LENGTH (EXT. 50 uM MULTIMODE FIBER) LENGTH (50 uM MULTIMODE FIBER) LENGTH (62.5 uM MULTIMODE FIBER) LENGTH (COPPER) 9.900 [Gbits/s] 11.100 [Gbits/s] 40 [Km] 0 [m] 0 [m] 0 [m] 0 [m] Device Technology [0111b] 1550 nm EML [0b] Transmitter not Tunable [0b] PIN detector [1b] Cooled transmitter [0b] No wavelength control 147 72 148 149 150 151 152 153 154 155 156 157 158 159 160-163 4F 45 20 53 4F 4C 55 54 49 4F 4E 53 20 [5] S-64.2b O (OE SOLUTION E F8 CDR Support 165 166 167 168 169 00 19 3A VENDOR OUI(165-167) ) S O L U T I O N S VENDOR NAME(148-163) 164 52 54 [07h] LC [5] 10GBASE-ER [1] 10GBASE-EW [7] [6] [5] [4] [3] VENDOR PN(168-183) CDR CDR CDR CDR CDR R 16 support for support for support for support for support for 00 19 3A 9.95 10.3 10.5 10.7 11.1 (RTXX0SER-ST5 T Gb/s Gb/s Gb/s Gb/s Gb/s ) Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 170 171 172 173 174 175 176 177 178 179 180-183 184 185 186 187 188 189 190 191 192 58 58 30 53 45 52 2D xx 54 35 20 31 20 79 18 0F A0 46 xx AF 193 1E 194 65 195 00 196-211 212-219 xx xx 220 00 221 60 222 74 223 224-255 xx FF X X 0 S E R S:53, E:45, I:49 T 5 VENDOR REV(184-185) 1 (1 ) LASER WAVELENGTH(186-187) 1550.00 [nm] WAVELENGTH TOLERANCE(188-189) 20.000 [nm] MAXIMUM CASE TEMPERATURE Check code for addresses 120 to 190 Maximum Power Dissipation Maximum Total Power Dissipation in Power Down Mode [7-4] Maximum current required by +5V Supply. [3-0] Maximum current required by +3.3V Supply. [7-4] Maximum current required by +1.8V Supply. [3-0] Maximum current required by -5.2V Supply VENDOR SN(196-211) Date Code(212-219) Diagnostic Monitoring Type [4] Module Respond to FEC BER [3] Received power measurement type Enhanced Options [7] Module Supports Optional VPS [6] Soft TX_DISABLE [5] Soft P_down [4] Supports VPS LV regulator mode [3] Supports VPS bypassed regulator Mode [2] Active FEC control functions [1] Wavelength tunability [0] Optional CMU Support Mode Auxiliary A/D Types [7-4] Aux A/D Input 1 [3-0] Aux A/D Input 2 Check code for addresses 192 to 222 VENDOR SPECIFIC ID FIELD(224-255) 17 70 [ ℃] Varies 3500 mW 300 mW 300 mA 500 mA 0 mA 0 mA Varies Varies [6] Optional Soft TX_DISABLE implemented [5] Optional Soft P_down [0110b] +3.3V Supply Voltage [0100b] Laser Temperature Varies Rev A.1, 01/23/2009 RTXX0SER XFP Transceiver Product Specifications 10. Regulatory Compliance RTXX0SER comply with international Electromagnetic Compatibility (EMC) and international safety requirements and standards. EMC performance is dependent on the overall system design. The RTXX0SER is lead-free and RoHS-compliant per Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. 11. Ordering Information Model Name OES P/C Operating Case Temperature Nominal Wavelength RTXX0SER-ST5 T7100 RTXX0SER-ET5 T7200 0oC to 70oC -5oC to 85oC RTXX0SER-IT5 T7300 -40oC to 85oC Notice: Application Distance 1550nm Latch Color RED SONET/SDH & 10G GbE 40km 1550nm RED SONET/SDH & 10G GbE 40km 1550nm RED SONET/SDH & 10G GbE 40km This data sheet is subject to change at any time without notice. Revision History; Date Rev. # Description Author 05/13/2008 Rev. 1.0 first release MSPARK 01/23/2009 Rev. A.1 LOS deassert is changed to -18dBm MSPARK Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com. OE Solutions America, Inc. 560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188, Fax:201-568-1177 18 Rev A.1, 01/23/2009