Transcript
RoHS Compliant
10Gb/s 1550nm XFP 40km Transceiver RTXX0SER
Applications
Features
Description
RoHS compliant 10Gb/s optical links Compliant with XFP MSA Support multi protocol from 9.9Gb/s to 11.1Gb/s Transmission distance of 40km over single mode fiber 1550nm EML laser transmitter LC duplex connector 2-wire interface for management and diagnostic monitor Hot pluggable 30 pin connector XFI electrical interface with AC coupling Power supply voltages : +3.3V, +5V Power dissipation: <3.5W Three optional operating temperature ranges : Option ST : 0°C to 70°C Option ET : -5°C to 85°C Option IT : -40°C to 85°C
www.oesolution.com
SONET OC-192 IR-2 / SDH S-64.2b 10GBASE-ER/EW Ethernet 40km 10G FC
OE Solutions’ XFP transceivers are designed to be compatible with the XFP 30pin Multi-Source Agreement (MSA). The high performance cooled 1550nm EML transmitter and high sensitivity PIN receiver provide superior performance for SONET/SDH and Ethernet applications up to 40km optical links. Advanced Digital Diagnostics functions are available via the 2-wire serial bus specified in the XFP MSA. The transmitter and receiver features ac-coupled differential data inputs and outputs, and an LVTTL for Tx disable input and Tx fault output. Software TX disable is also implemented. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output.
1
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
1. Absolute Maximum Ratings Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Vcc3_max
0
-
4.0
V
-
Vcc5_max
0
-
6.0
V
-
Operating Case Temperature
Top
-40
-
85
°C
-
Storage Temperature
Tst
-40
-
85
°C
-
Symbol
Min.
Typ.
Max.
Unit
Notes
B
9.9
10.3
11.1
Gb/s
-
-
-
Absolute Supply Voltage
2. General Operating Conditions Parameter Bit Rate Bit Error Rate
BER
-
-
Maximum Transmission Distance
Dmax
-
40
-
km
-
Vcc3
3.135
-
3.465
V
-
Vcc5
4.75
-
5.25
V
-
Top
-40
-
85
°C
1,2
Power supply current
ICC3
-
200
500
mA
3
Power supply current
ICC5
-
300
mA
-
Operating Voltage Operating Case Temperature
Notes :
10
-12
1. Measured on bottom side front center of XFP module 2. There are three options of operating maximum temperature: Option ST: standard temperature from 0oC to 70oC, Option ET: extended temperature from -5oC to 85oC,Option IT: extended temperature from -40oC to 85oC 3. Powers TEC; current draw depends on temperature
3. Electrical Specifications 3.1 Module Electrical Specifications (Over Operating Case Temperature and Power Supply Range) Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Vol
0.0
-
0.4
V
-
Voh
Vcc-0.5
-
Vcc+0.3
V
1
Vil
-0.3
-
0.8
-
-
Vih
2.0
-
Vcc3+0.3
-
-
Interrupt Assert Delay
Interrupt_on
-
-
200
ms
-
Interrupt Negate Delay
Interrupt_off
-
-
500
µs
-
Mod_NR Assert / Negate Delay
-
-
-
1
ms
-
P-Down Reset Time
-
10
-
-
µs
-
XFP Interrupt, Mod_NR P_Down/RST
Note :
1. Vcc is the voltage of host board
2
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
3.2 Transmitter Electrical Specifications (Over Operating Case Temperature and Power Supply Range)
Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Differential Input Impedance
Rin
-
100
-
Ω
-
Differential Data Input Swing
Vin,pp
150
-
1000
mVp-p
-
Tx Disable Voltage
Vd
2.0
-
-
Vcc+0.3
-
Tx Enable Voltage
Ven
0
-
0.8
V
-
Tx Disable Assert Time
T_off
-
-
10
µs
-
Tx Enable Assert Time
T_on
-
-
2
ms
-
T_start
-
-
300
ms
-
Initialization Time
3.3. Receiver Electrical Specifications (Over Operating Case Temperature and Power Supply Range)
Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
B
9.9
10.3
11.1
GBd
-
Differential Output Impedance
Rout
-
100
-
Ω
-
Differential Data Output Swing
Vout
300
600
750
mVp-p
-
Data Output Rise/Fall Time
tr/tf
-
-
45
ps
-
LOS Output High Voltage
Vlosh
Vcc-0.5
LOS Output Low Voltage
Vlosl
-
-
0.5
V
T_los_onoff
-
-
100
µs
Data Rate
LOS Assert/Deassert Time Delay Note :
Vcc-0.3
1 -
1. Vcc is the voltage of host board
3
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
4. Optical Specifications 4.1 Transmitter Optical Specifications (Over Operating Case Temperature and Power Supply Range)
Optical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Optical Power
Pout
-1
-
2
dBm
1
Optical Modulation Amplitude (10GE)
OMA
-1.7
-
-
dBm
-
ER
8.2
-
-
dB
-
λ
1530
1550
1565
nm
-
SMSR
30
-
-
dB
-
∆λ
-
-
1
nm
-
Pout-off
-
-
-30
dBm
-
RIN12OMA
-
-
-130
dB/Hz
-
Optical Return Loss Tolerance
-
-
-
27
dB
-
Optical Path Penalty (Dispersion: 800ps/nm)
-
-
-
2
dB
-
Optical Extinction Ratio Optical Wavelength Side Mode Suppression Ratio Spectral Width
Optical power of OFF transmitter Relative Intensity Noise
Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-825 standards. They must be operated under specified operating conditions.
4.2. Receiver Optical Specifications (Over Operating Case Temperature and Power Supply Range)
Optical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
λ
1270
1310
1600
nm
-
RSENS1
-
-15.8
dBm
1
RSENS2
-
-
-11.3
dBm
1
Pol
0.5
-
-
dBm
-
-
-
-
-27
dB
-
LOS Assert
LOS_A
-28
-
-
dBm
-
LOS De-assert
LOS_D
-
-
-18
dBm
-
LOS Hysteresis
-
-
2
5
dB
-
Optical Wavelength Receiver
[email protected]/s Stressed Receiver Sensitivity (OMA)@10.3125Gb/s Maximum Input Power Receiver Reflectance
Notes :
1. Measured with a PRBS of 231-1 at 1 x 10-12 BER and 8.2dB extinction ratio
4
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
5. Pin Descriptions
XFP Transceiver Electrical Pad Layout
5
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
Pin Descriptions (continued) Pin
Logic
Symbol
Description
Notes
1 2
-
GND VEE5
1
3
LVTTL-I
Mod_DeSel
4
LVTTL-O
5 6 7
LVTTL-I -
TX_DIS VCC5 GND
Module Ground Not required Module De-select; When held low allows module to respond to 2-wire serial interface Interrupt; Indicates presence of an important condition which can be read over the 2-wire serial interface Transmitter Disable; Turns off transmitter laser output +5V Power Supply Module Ground
8
-
VCC3
+3.3V Power Supply
9 10
LVTTL-I/O
VCC3 SCL
+3.3V Power Supply 2-Wire Serial Interface Clock
2
11
LVTTL-I/O
SDA
2-Wire Serial Interface Data Line
2
12 13 14
LVTTL-O LVTTL-O LVTTL-O
Mod_Abs Mod_NR RX_LOS
Indicates Module is not present. Grounded in the Module Module Not Ready; Indicating Module Operational Fault Receiver Loss Of Signal Indicator
2 2 2
15
-
GND
Module Ground
1
16 17 18
CML-O CML-O
GND RDRD+
Module Ground Receiver Inverted Data Output, AC coupled in the module Receiver Non-Inverted Data Output, AC coupled in the module
1
19 20
-
GND VCC2
1 3
21
LVTTL-I
P_Down/RST
Module Ground Not required Power down; When high, requires the module to limit power consumption to 1.5W or below. 2-Wire serial interface must be functional in the low power mode.
22 23 24 25 26 27 28 29 30
Notes :
PECL-I PECL-I CML-I CML-I -
Interrupt
VCC2 GND RefCLK+ RefCLKGND GND TDTD+ GND
Reset; The falling edge initiates a complete reset of the module including the 2wire serial interface, equivalent to a power cycle. No use Module Ground Not required Not required Module Ground Module Ground Transmitter Inverted Data Input, AC coupled in the module Transmitter Non-Inverted Data Input, AC coupled in the module Module Ground
2
1
3 1
1 1
1
1. Module ground pins Gnd are isolated from the module case and chassis ground within the module. 2. Shall be pulled up with 4.7K-10Kohms to a voltage between 3.15V and 3.45V on the host board.
6
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
6. Outline Drawings Dimensions are in millimeters
7
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
7. PCB layout and Bezel recommendation Dimensions are in millimeters
XFP Host Board Mechanical Layout
8
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
PCB layout and Bezel recommendation (continued)
XFP Host Board Mechanical Layout
Recommended Single Sided Bezel Design 9
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
8. SFP+ Block Diagram, Power Supply Information and Host Board Interface 8.1 XFP Block Diagram and Host Board Interface Pin 5 Pin 29
Tx Disable TD+
TOSA
Laser
Zin diff.= 100Ω
100Ω
TD-
Pin 28
Pin 10
Management processor SCL
EEPROM
Pin 11
SDA
Pin 17 RD-
ROSA
Zout = 50Ω
Post amp.
each arm
RD+
Pin 18 Pin 8, 9
VCC3
Pin 6
VCC5
Pin 2
VEE5 (Not used)
Pin 22
VCC2 (Not used)
Pin 24,25
Mod_DeSel, P_Down/RST
Pin 3, 21
Module
Pin 1, 7, 15, 16,
GND
19, 23, 26, 27 VCC3 R
RefCLK+/- (Not used)
Interrupt, RX_LOS
Pin 4,14 R Mod_Abs, Mod_NR Pin 12, 13
SCL. SDA
R
Pin 10, 11
R= 4.7k ~ 10kΩ
Note 1: Host board output device circuit in the transmitter side and host board input device circuit in the receiver should be carefully designed to meet 100ohm differential impedance matching. Also necessary is the dc bias circuit of each input and output by taking into account of ac coupling of data input ant output of XFP module. For the interface of host board devices, it is recommended to refer to the device vendor’s data sheet.
10
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
8.2 Recommended Host Board Supply Filtering Network
4.7µH VCC3
Vcc3 0.1µF
22µF
0.1µF
4.7µH Vcc5
VCC5 0.1µ
XFP Module
0.1µF
22µF
HOST BOARD
9. Digital Diagnostic Monitoring and Serial ID Operation Serial ID and Map: page A0h Address 0
HEX 06
1
00
2 3 4 5 6 7 8 9 10-17 18 19 20 21 22 23 24 25 26 27
varies varies varies varies varies varies varies varies 00 EA 60 3A 98 D6 D8 4E 20 4D F1
Name of Fields Identifier Signal Conditioner Control Field [7-4] Data Rate Control [2] Lineside Loopback [1] XFI Loopback [0] Signal Conditioner Control Temp High Alarm MSB Temp High Alarm LSB Temp Low Alarm MSB Temp Low Alarm LSB Temp High Warning MSB Temp High Warning LSB Temp Low Warning MSB Temp Low Warning LSB Reserved A/D Flag Thresholds(10-17) Bias High Alarm MSB Bias High Alarm LSB Bias Low Alarm MSB Bias Low Alarm LSB Bias High Warning MSB Bias High Warning LSB Bias Low Warning MSB Bias Low Warning LSB TX Power High Alarm MSB TX Power High Alarm LSB
11
Description [06h] XFP Signal Conditioner Control Field Data Rate Control(01[7:4]) = 9.50 Gb/s [0b] Normal Operation [0b] Normal Operation [0b] Normal Asynchronous REFCLK mode ST: 100.00 [ ], ET and IT: 120.00 [ ]
℃
℃
℃
℃
℃
ST: -5.00 [ ], ET: -10.00 [ ], IT: -45.00 [ ],
℃
℃] ST: 0.00 [℃], ET: -5.00 [℃], IT: -40.00 [℃], ST: 90.00 [ ], ET and IT: 110.00 [
120.00 [mA] 30.00 [mA] 110.0 [mA] 40.0 [mA] 3.0 [dBm]
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57
13 94 3D E9 18 A6 31 2D 00 9E 2B D4 00 C8 8C A0 75 30 88 B8 79 18 32 00 19 00 2D 00 1E 00
58
00
59
00
60-69 70 71 72 73 74 75 76 77 78 79
00 00 00 00 00 00 00 80 00 00 00
TX Power Low Alarm MSB TX Power Low Alarm LSB TX Power High Warning MSB TX Power High Warning LSB TX Power Low Warning MSB TX Power Low Warning LSB RX Power High Alarm MSB RX Power High Alarm LSB RX Power Low Alarm MSB RX Power Low Alarm LSB RX Power High Warning MSB RX Power High Warning LSB RX Power Low Warning MSB RX Power Low Warning LSB AUX 1 High Alarm MSB (power supply) AUX 1 High Alarm LSB (power supply) AUX 1 Low Alarm MSB (power supply) AUX 1 Low Alarm LSB (power supply) AUX 1 High Warning MSB (power supply) AUX 1 High Warning LSB (power supply) AUX 1 Low Warning MSB (power supply) AUX 1 Low Warning LSB (power supply) AUX 2 High Alarm MSB (Laser Temp) AUX 2 High Alarm LSB (Laser Temp) AUX 2 Low Alarm MSB (Laser Temp) AUX 2 Low Alarm LSB (Laser Temp) AUX 2 High Warning MSB (Laser Temp) AUX 2 High Warning LSB (Laser Temp) AUX 2 Low Warning MSB (Laser Temp) AUX 2 Low Warning LSB (Laser Temp) VPS Fields [7-4] Lowest Voltage Supported with an Operational LV Regulator [3-0] Voltage Supplied on the VCC2 Pins VPS Fields [7-4] Voltage Supported with a Bypassed Regulator [0] Regulator bypass mode
-3.0 [dBm] 2.0 [dBm] -2.0 [dBm] 1.0 [dBm] -18.0 [dBm] 0.5 [dBm] -17.0 [dBm] 3.6 [V] 3.0 [V] 3.5 [V] 3.1 [V]
℃ 25.00 [℃] 45.00 [℃] 30.00 [℃] 50.00 [ ]
Not Supported
Not Supported
Acceptable BER Actual BER
Not Supported Not Supported
Wavelength Set MSB(72-73)
Not Supported
Wavelength Error LSB(74-75)
Not Supported
Amplitude Adjustment Phase Adjustment
0.00 [%] Not Supported
Reserved(78-79)
12
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
80
xx
81
xx
82
xx
83
xx
84
xx
85
xx
86
xx
Latched Interrupt Flag Fields(80) [7] L-Temp High Alarm [6] L-Temp Low Alarm [3] L-TX Bias High Alarm [2] L-TX Bias Low Alarm [1] L-TX Power High Alarm [0] L-TX Power Low Alarm Latched Interrupt Flag Fields(81) [7] L-RX Power High Alarm [6] L-RX Power Low Alarm [5] L-AUX 1 High Alarm [4] L-AUX 1 Low Alarm [3] L-AUX 2 High Alarm [2] L-AUX 2 Low Alarm Latched Interrupt Flag Fields(82) [7] L-Temp High Warning [6] L-Temp Low Warning [3] L-TX Bias High Warning [2] L-TX Bias Low Warning [1] L-TX Power High Warning [0] L-TX Power Low Warning Latched Interrupt Flag Fields(83) [7] L-RX Power High Warning [6] L-RX Power Low Warning [5] L-AUX 1 High Warning [4] L-AUX 1 Low Warning [3] L-AUX 2 High Warning [2] L-AUX 2 Low Warning Latched Interrupt Flag Fields(84) [7] L-TX_NR [6] L-TX_Fault [5] L-TX CDR [4] L-RX_NR [3] L-RX_LOS [2] L-RX CDR [1] L-MOD_NR [0] L-Reset Latched Interrupt Flag Fields(85) [7] L-APD Supply Fault [6] L-TEC Fault [5] L-Wavelength Unlocked Latched Interrupt Flag Fields(86) [7] L-VCC5 High Alarm [6] L-VCC5 Low Alarm [5] L-VCC3 High Alarm [4] L-VCC3 Low Alarm [3] L-VCC2 High Alarm [2] L-VCC2 Low Alarm [1] L-Vee5 High Alarm [0] L-Vee5 Low Alarm
13
Varies
Varies
Varies
Varies
Varies
Varies
Varies
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
87
xx
88
00
89
00
90
00
91
00
92
00
93
00
Latched Interrupt Flag Fields(87) [7] L-VCC5 High Warning [6] L-VCC5 Low Warning [5] L-VCC3 High Warning [4] L-VCC3 Low Warning [3] L-VCC2 High Warning [2] L-VCC2 Low Warning [1] L-Vee5 High Warning [0] L-Vee5 Low Warning Interrupt Masking Bits(88) [7] M-Temp High Alarm [6] M-Temp Low Alarm [3] M-TX Bias High Alarm [2] M-TX Bias Low Alarm [1] M-TX Power High Alarm [0] M-TX Power Low Alarm Interrupt Masking Bits(89) [7] M-RX Power High Alarm [6] M-RX Power Low Alarm [5] M-AUX 1 High Alarm [4] M-AUX 1 Low Alarm [3] M-AUX 2 High Alarm [2] M-AUX 2 Low Alarm Interrupt Masking Bits(90) [7] M-Temp High Warning [6] M-Temp Low Warning [3] M-TX Bias High Warning [2] M-TX Bias Low Warning [1] M-TX Pow.High Warning [0] M-TX Pow.Low Warning Interrupt Masking Bits(91) [7] M-RX Pow.High Warning [6] M-RX Pow.Low Warning [5] M-AUX 1 High Warning [4] M-AUX 1 Low Warning [3] M-AUX 2 High Warning [2] M-AUX 2 Low Warning Interrupt Masking Bits(92) [7] M-TX_NR [6] M-TX_Fault [5] M-TX CDR not Locked [4] M-RX_NR [3] M-RX_LOS [2] M-RX CDR not Locked [1] M-MOD_NR [0] M-Reset Complete Interrupt Masking Bits(93) [7] M-APD Supply Fault [6] M-TEC Fault [5] M-Wavelength Unlocked
14
Varies
Varies
Varies
Varies
Varies
Varies
Varies
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
94
00
95
00
96 97 98-99 100 101 102 103 104 105 106 107 108 109
xx xx 00 xx xx xx xx xx xx xx xx xx xx
110
xx
111
xx
112-117
00
118
00
119-126 127 128
00 01 06
Interrupt Masking Bits(94) [7] M-VCC5 High Alarm [6] M-VCC5 Low Alarm [5] M-VCC3 High Alarm [4] M-VCC3 Low Alarm [3] M-VCC2 High Alarm [2] M-VCC2 Low Alarm [1] M-Vee5 High Alarm [0] M-Vee5 Low Alarm Interrupt Masking Bits(95) [7] M-VCC5 High Warning [6] M-VCC5 Low Warning [5] M-VCC3 High Warning [4] M-VCC3 Low Warning [3] M-VCC2 High Warning [2] M-VCC2 Low Warning [1] M-Vee5 High Warning [0] M-Vee5 Low Warning Temperature MSB (Module Temp) Temperature LSB (Module Temp) Reserved(98-99) TX Bias MSB TX Bias LSB TX Power MSB TX Power LSB RX Power MSB RX Power LSB AUX 1 MSB AUX 1 LSB AUX 2 MSB AUX 2 LSB Control/Status Bits [7] TX Disable State [6] Soft TX Disable [5] MOD_NR State [4] P_Down State [3] Soft P_Down [2] Interrupt [1] RX_LOS [0] Data_Not_Ready Control/Status Bits [7] TX_NR State [6] TX_Fault [5] TX_CDR [4] RX_NR [3] RX_CDR Pcket Error Checking [0] Error Checking
Varies
Varies
Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies Varies
Varies
Varies
[0b] Disable Packet Error Checking
Table Select Identifier
[06h] XFP
15
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications [10b] Power Level 3 Module (3.5W max.power dissipation.) [0] Module with CDR function [1] TX Ref Clock Input Not Required [1] CLEI code present in Table 02h
129
98
Extended Identifier
130
07
Connector
131
22
Gigabit Ethernet Compliance
132 133 134 135
00 00 00 00
Gigabit Fibre Channel Compliance Gigabit Copper Links Lower Speed Links SONET/SDH Codes -Interconnect
136
20
SONET/SDH Codes Short Haul
137 138
00 00
SONET/SDH Codes Long Haul SONET/SDH Codes Very Long Haul
139
10
Encoding
[4] NRZ
140 141 142 143 144 145 146
63 6F 28 00 00 00 00
BR,MINIMUM BR,MAXIMUM LENGTH (Km) LENGTH (EXT. 50 uM MULTIMODE FIBER) LENGTH (50 uM MULTIMODE FIBER) LENGTH (62.5 uM MULTIMODE FIBER) LENGTH (COPPER)
9.900 [Gbits/s] 11.100 [Gbits/s] 40 [Km] 0 [m] 0 [m] 0 [m] 0 [m]
Device Technology
[0111b] 1550 nm EML [0b] Transmitter not Tunable [0b] PIN detector [1b] Cooled transmitter [0b] No wavelength control
147
72
148 149 150 151 152 153 154 155 156 157 158 159 160-163
4F 45 20 53 4F 4C 55 54 49 4F 4E 53 20
[5] S-64.2b
O
(OE SOLUTION E
F8
CDR Support
165 166 167 168 169
00 19 3A
VENDOR OUI(165-167)
)
S O L U T I O N S
VENDOR NAME(148-163)
164
52 54
[07h] LC [5] 10GBASE-ER [1] 10GBASE-EW
[7] [6] [5] [4] [3]
VENDOR PN(168-183)
CDR CDR CDR CDR CDR
R
16
support for support for support for support for support for 00 19 3A
9.95 10.3 10.5 10.7 11.1
(RTXX0SER-ST5 T
Gb/s Gb/s Gb/s Gb/s Gb/s
)
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications 170 171 172 173 174 175 176 177 178 179 180-183 184 185 186 187 188 189 190 191 192
58 58 30 53 45 52 2D xx 54 35 20 31 20 79 18 0F A0 46 xx AF
193
1E
194
65
195
00
196-211 212-219
xx xx
220
00
221
60
222
74
223 224-255
xx FF
X X 0 S E R S:53, E:45, I:49 T 5 VENDOR REV(184-185)
1
(1 )
LASER WAVELENGTH(186-187)
1550.00 [nm]
WAVELENGTH TOLERANCE(188-189)
20.000 [nm]
MAXIMUM CASE TEMPERATURE Check code for addresses 120 to 190 Maximum Power Dissipation Maximum Total Power Dissipation in Power Down Mode [7-4] Maximum current required by +5V Supply. [3-0] Maximum current required by +3.3V Supply. [7-4] Maximum current required by +1.8V Supply. [3-0] Maximum current required by -5.2V Supply VENDOR SN(196-211) Date Code(212-219) Diagnostic Monitoring Type [4] Module Respond to FEC BER [3] Received power measurement type Enhanced Options [7] Module Supports Optional VPS [6] Soft TX_DISABLE [5] Soft P_down [4] Supports VPS LV regulator mode [3] Supports VPS bypassed regulator Mode [2] Active FEC control functions [1] Wavelength tunability [0] Optional CMU Support Mode Auxiliary A/D Types [7-4] Aux A/D Input 1 [3-0] Aux A/D Input 2 Check code for addresses 192 to 222 VENDOR SPECIFIC ID FIELD(224-255)
17
70 [
℃]
Varies 3500 mW 300 mW
300 mA 500 mA
0 mA 0 mA Varies Varies
[6] Optional Soft TX_DISABLE implemented [5] Optional Soft P_down
[0110b] +3.3V Supply Voltage [0100b] Laser Temperature Varies
Rev A.1, 01/23/2009
RTXX0SER XFP Transceiver Product Specifications
10. Regulatory Compliance RTXX0SER comply with international Electromagnetic Compatibility (EMC) and international safety requirements and standards. EMC performance is dependent on the overall system design. The RTXX0SER is lead-free and RoHS-compliant per Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
11. Ordering Information Model Name
OES P/C
Operating Case Temperature
Nominal Wavelength
RTXX0SER-ST5
T7100
RTXX0SER-ET5
T7200
0oC to 70oC -5oC to 85oC
RTXX0SER-IT5
T7300
-40oC to 85oC
Notice:
Application
Distance
1550nm
Latch Color RED
SONET/SDH & 10G GbE
40km
1550nm
RED
SONET/SDH & 10G GbE
40km
1550nm
RED
SONET/SDH & 10G GbE
40km
This data sheet is subject to change at any time without notice.
Revision History;
Date
Rev. #
Description
Author
05/13/2008
Rev. 1.0
first release
MSPARK
01/23/2009
Rev. A.1
LOS deassert is changed to -18dBm
MSPARK
Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com.
OE Solutions America, Inc.
560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188, Fax:201-568-1177
18
Rev A.1, 01/23/2009