Transcript
RoHS Compliant
10Gb/s DWDM SFP+ 80km Transceiver RDPX0SZR-xxx
Applications
Features
SONET OC-192 / STM-64 : P16L1-2A2 10GBASE-ZR/ZW Ethernet 80km 10G FC G.709 OUT-2
Description
RoHS compliant Support multi protocol from 9.9Gb/s to 11.3Gb/s
OE Solutions’ Small Form Factor Pluggable (SFP+) transceivers are compatible with the Small Form Factor Pluggable 20pin MultiSource Agreement (MSA). The high performance cooled DWDM EML transmitter and high sensitivity APD receiver provide superior performance for SONET/SDH and Ethernet applications up to 80km optical links. Enhanced Digital Diagnostics functions are available via the 2-wire serial bus specified in the SFF-8472 Rev. 11.0. The transmitter and receiver features ac-coupled differential data inputs and outputs, and an LVTTL for Tx disable input and Tx fault output. Software TX disable is also implemented. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output.
Compliant with SFP+ MSA, SFF 8431 Rev. 4.1 Compliant with SFF 8432 Rev.4.3 mechanical dimension Compliant with Digital diagnostic SFF-8472 Rev.11.0 Transmission distance of 80km over single mode fiber C-band DWDM EML laser transmitter LC duplex connector Hot pluggable 20 pin connector Single power supply voltage : +3.3V Low power dissipation Three optional operating temperature ranges : Option ST :
0°C to 70°C
Option ET :
-5°C to 85°C
Option IT :
-40°C to 85°C
1
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
1. Absolute Maximum Ratings Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Vcc_max
0
-
3.6
V
-
Operating Case Temperature
Top
-40
-
85
°C
1,3
Operating Relative Humidity
RHop
5
-
90
%
2
Tst
-40
-
85
°C
2
5
-
95
%
2
Absolute Supply Voltage
Storage and Transportation Temperature Storage and Transportation Relative Humidity Notes:
1. Measured on top side front center of SFP module 2. Non-condensing 3.There are three options of operating maximum temperature: Option ST: standard temperature from 0oC to 70oC, Option ET: extended temperature from -5oC to 85oC Option IT: extended temperature from -40oC to 85oC
2. General Operating Conditions Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
B
9.9
10.3
11.3
Gb/s
-
Dmax
80
-
-
km
-
Operating Voltage
Vcc
3.14
-
3.46
V
-
-
-
650
mA
ST
Power Supply Current
ICC
-
-
750
mA
ET, IT
Total Power Consumption
-
-
2.1
W
-
ESD (High speed pins)
-
-
500
V
2
Bit Rate Maximum Transmission Distance
Notes :
1. Supplies TEC, Current draw depends on Temperature 2. Human body model per JEDEC JESD22-A114-B, compliant with INF-8077i Rev. 4.5 August 31, 2005
2
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
3. Electrical Specifications 3.1 Transmitter Electrical Specifications (Over Operating Case Temperature and Power Supply Range)
Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Differential Input Impedance
Rin
80
100
120
Ω
-
Differential Data Input Swing
Vin,pp
180
-
800
mVp-p
-
Data Input Rise/Fall Time
tr/tf
15
-
40
ps
Tx Disable Voltage
Vd
2.0
-
Vcc+0.3
V
1
Tx Enable Voltage
Ven
0
-
0.8
V
-
Tx Fault Output Low
Vtfl
-
-
0.4
V
-
Tx Disable Assert Time
T_off
-
-
100
s
-
Tx Enable Assert Time
T_on
-
-
2
ms
-
Tx Fault Assert Time
Tx_f_on
-
-
1
s
-
Tx Fault Reset Time
Tx_reset
10
-
-
s
-
T_start_up_cooled
-
-
90
s
-
Initialization Time Note :
1. Vcc is the voltage of host board
3.2. Receiver Electrical Specifications (Over Operating Case Temperature and Power Supply Range)
Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
B
9.9
10.3
11.3
GBd
-
Differential Output Impedance
Rout
80
100
120
Ω
-
Differential Data Output Swing
Vout
300
-
800
mVp-p
-
Data Output Rise/Fall Time
tr/tf
-
-
45
ps
-
LOS Output High Voltage
Vlosh
Vcc-0.5
-
Vcc+0.3
V
1
LOS Output Low Voltage
Vlosl
0
-
0.4
V
-
T_los on/off
-
-
100/100
s/s
-
Data Rate
LOS Assert/Deassert Time Delay Note :
1. Vcc is the voltage of host board
3
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
4. Optical Specifications 4.1 Transmitter Optical Specifications (Over Operating Case Temperature and Power Supply Range)
Optical Characteristics Parameter
Symbol
Min.
Laser Safety Class
Typ.
Max.
Unit
Class 1 according to IEC60825
Notes -
λ
1529
-
1562
nm
-
Average Optical Output Power
Pout
-1
-
4
dBm
1
Optical Power Overshoot
Pov
-
-
1
dB
2
Pout-off
-
-
-40
dBm
-
-8
-
8
GHz
3
Pout
-1
-
+1
dB
-
SMSR
35
-
-
dB
4 5
Optical Wavelength
Optical power of OFF transmitter Spectral Width Optical Output Power Variation (with respect to BOL Tc=25C, and nominal power supply) Side Mode Suppression Ratio Wavelength
BOL
T
-50
-
+50
pm
Deviation
EOL
a
-100
-
+100
pm
ER
8.2
-
-
dB
-
Tr, Tf
-
-
35
ps
-
-
-
-
-
6
Optical Extinction Ratio(Filtered) Optical Rise/Fall Time (20%-80%) Output Jitter Notes:
1. Average power measured at output 2. Defined as Peak power – Steady-state power (in dBm) when Tx-dis is de-asserted or when the module is hot plugged with Tx_dis in low state (Tx enabled). 3. Full spectral width (RBW=0.1nm) measured 15dB down from the maximum of center wavelength peak under full modulation condition 4. Ratio of the average output power in the dominant longitudinal mode to the power in the most significant side mode peak under full modulation condition 5. Deviation related to the ITU standardized wavelength. The EOL value is met as soon as the output average power is above 10% of the steady-state power. 6. The jitter performance meets Telcodia GR-253-Core and ITU-T Recommendations G.783, G813, G825 and G82511 with ITU-T 0.172(04/2005) for the measurement methods and the measurement equipment.
Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
4
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
4.2 ITU Channel and Wavelength Guide ITU Channel
Frequency (THz)
Wavelength (nm)
ITU Channel
Frequency (THz)
Wavelength (nm)
39
193.9
1546.12
40
194.0
1545.32
17
191.7
1563.86
41
194.1
1544.53
18
191.8
1563.05
42
194.2
1543.73
19
191.9
1562.23
43
194.3
1542.94
20
192.0
1561.42
44
194.4
1542.14
21
192.1
1560.61
45
194.5
1541.35
22
192.2
1559.79
46
194.6
1540.56
23
192.3
1558.98
47
194.7
1539.77
24
192.4
1558.17
48
194.8
1538.98
25
192.5
1557.36
49
194.9
1538.19
26
192.6
1556.56
50
195.0
1537.40
27
192.7
1555.75
51
195.1
1536.61
28
192.8
1554.94
52
195.2
1535.82
29
192.9
1554.13
53
195.3
1535.04
30
193.0
1553.33
54
195.4
1534.25
31
193.1
1552.52
55
195.5
1533.47
32
193.2
1551.72
56
195.6
1532.68
33
193.3
1550.92
57
195.7
1531.90
34
193.4
1550.12
58
195.8
1531.12
35
193.5
1549.32
59
195.9
1530.33
36
193.6
1548.51
60
196.0
1529.55
37
193.7
1547.72
38
193.8
1546.92
5
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
4.3. Receiver Optical Specifications (Over Operating Case Temperature and Power Supply Range)
Optical Characteristics Parameter
Max.
Unit
Notes
1563
nm
-
-
-23
dBm
1, 2
-6.0
-
-
dBm
-
-
-
-
-27
dB
-
LOS Assert
LOS_A
-35
-
-
dBm
-
LOS De-assert
LOS_D
-
-
-23
dBm
-
-
0.5
-
5
dB
-
Optical Wavelength Average Rx Sensitivity@10Gb/s Maximum Input Power Receiver Reflectance
LOS Hysteresis Notes :
31
Symbol
Min.
λ
1528
RSENS
-
Pol
Typ.
-12
1. Measured with a PRBS of 2 -1 at 1x10 BER and 8.2 dB extinction ratio, 1450ps/nm 2. Guaranteed after 80km transmission over the entire operating temperature range.
6
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
5. Pin Descriptions
20
Tx GND
1
Tx GND
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
Tx GND
4
16
VccT
15
VccR
14
Rx GND
13
RD+
12 11
5
SDA SCL
6
Mod_ABS
7
RS0
8
Rx_LOS
RD-
9
RS1
Rx GND
10
Rx GND
Top of Board
Bottom of Board
SFP Transceiver Electrical Pad Layout
7
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
Pin Descriptions (continued) Pin 1 2 3 4 5 6
Logic LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I/O -
Symbol Tx GND Tx Fault Tx Disable SDA SCL MOD_ABS
7
LVTTL-I
RS0
8
LVTTL-O
Rx LOS
9 10 11 12 13 14 15 16 17 18 19 20
LVTTL-I CML-O CML-O CML-I CML-I -
RS1 Rx GND Rx GND RDRD+ Rx GND Vcc Rx Vcc Tx Tx GND TD+ TDTx GND
Description Transmitter Ground Transmitter Fault Indication Transmitter Disable 2 wire Serial Interface Data Line 2 wire Serial Interface Clock Module Absent, connected to Tx GND or Rx GND in the module Rate Select 0, not used Receiver Loss of Signal Indication (In FC designated as Rx_LOS and in Ethernet designated as Signal Detect Bar Rate Select 1, not used Receiver Ground Receiver Ground Receiver Negative Data Out Receiver Positive Data Out Receiver Ground Receiver Power, 3.3V±5% Transmitter Power, 3.3V±5% Transmitter Ground Transmitter Positive Data In Transmitter Negative Data In Transmitter Ground
Plug Seq. * 1 3 3 3 3
Notes 1 2 3 4 4
3
5
3
6
3
7
3 1 1 3 3 1 2 2 1 3 3 1
6 1 1 1 1 1
*Plug Seq. : Pin engagement sequence during hot plugging Notes : 1. The module ground contacts, Tx GND abd Rx GND, shall be isolated frim the module case, that is, frame ground. 2. Tx Fault is an open collector/drain output that shall be pulled up with a 4.7k ~ 10k on the host board. Pull up voltage between 2.0V and VccT + 0.5V. When high, output indicates a laser fault of some kind. When low, output indicates normal operation. The LD output is not turned off in case of Tx Fault 3. Tx Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the TRx with a 4.7k ~ 10k to VccT. 4. SDA and SCL should be pulled up with a 4.7k ~ 10k on the host board. The pull-up voltage shall be VccT. SCL is the clock line of 2-wire serial interface for serial ID. SDA is the data line of 2-wire serial interface for serial ID. 5. Mod_ABS is connected to Tx GND or Rx GND in the SFP+ module. The host may pull the contact up to Vcc on the host board with a resistor in the range 4.7 ~ 10k. Mod_ABS is asserted “high” when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF-8074i) this contact has the same function but is called MOD_DEF0. 6. RS0 and RS1 are module input rate select contacts and are pulled low to Tx GND with a >30k resistor in the module. RS0 is an input hardware contact which optionally selects the optical receive data path rate coverage for an SFP+ module. RS1 is an input hardware contact which optionally selects the optical transmit path data rate coverage for the SFP+ module. These contacts can also be used for AS0 and AS1 if implementing SFF8079. RS1 is commonly connected to Tx GND or Rx GND in the classical SFP modules. The host needs to ensure that it will not be damaged if this contact is connected to Tx GND or Rx GND in the module. For logical definitions of RS0/RS1, see Section 2.5 of SFF-8431 Rev. 2.1. 7. LOS is an open collector output. Shall be pulled up with a 4.7k ~ 10k on host board. Pull up voltage between 2.0 and VccR+0.3. Logic 0 indicates normal operation.
8
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
5. Outline Drawings Dimensions are in millimeters
9
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
6. PCB layout and Bezel recommendation Dimensions are in inches (millimeters)
Notes :
1. Datum and basic dimensions established by customer. 2. Pads and vias are chassis ground, 11 locations 3. Thru holes, plating optional.
10
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
7. PCB layout and Bezel recommendation (continued)
Notes : Thru holes, plating optional.
Recommended Panel Opening
11
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
8. SFP+ Block Diagram, Power Supply Information and Host Board Interface 8.1 SFP+ Block Diagram Pin 3 10k
Vcc Tx
Pin 18
Tx Disable
Zin diff.=
TD+
TOSA
Pin 16
Laser 100 TDdriver Tx Fault
100 Pin 19 Pin 2 Pin 5
Management processor SCL
EEPROM
Pin 4
SDA Vcc Rx
Pin 15 Pin 12
RD-
TOSA
Zout = 50 each arm
Post amp. RD+ LOS
Pin 13 Pin 8 Pin 10, 11, 14 Rx_GND
Pin 1, 17, 20
Tx_GND RS0
Pin 7
Mod ABS Pin 6 RS1 Pin 9
12
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
8.2 Recommended Host Board Supply Filtering Network 1H Vcc Tx 0.1F Tx GND 1H
Vcc +3.3V
Vcc Rx 0.1F 10F 0.1F
10F
Rx GND
SFP+ Module
HOST BOARD
Host Board GND
8.3 SFP+ Host Board Interface Vcc 10k
Vcc 10k Vcc 10k Vcc 10k
Vcc 10k
1 Tx GND
Tx GND 20
2 Tx Fault
TD- 19
3 Tx Disable
TD+ 18
4 SDA
Tx GND 17
5 SCL
Vcc Tx 16
6 Mod ABS
Vcc Rx 15
7 RS0
Host board Device
Refer to Section 8.2 RX GND 14
8 Rx LOS
RD+ 13
9 RS1
RD- 12
10 Rx GND
Differential 100(note 1)
Rx GND 11
Host board Device Differential 100(note 1)
SFP+ Module
Note 1: Host board output device circuit in the transmitter side and host board input device circuit in the receiver should be carefully designed to meet 100ohm differential impedance matching. Also necessary is the dc bias circuit of each input and output by taking into account of ac coupling of data input ant output of SFP+ module. For the interface of host board devices, it is recommended to refer to the device vendor’s data sheet. 13
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
9. Digital Diagnostic Monitoring and Serial ID Operation The information is accessed through the pin 4 (SDA), and pin 5(SCL) of the module. The device address used to read the Serial ID data is 1010000X(A0h), and the address to read the diagnostic data is 1010001X(A2h). The EEPROM Write Protect pin is internally tied to ground with no external access, allowing write access to the customer-writable field (bytes 128-247 of address 1010001X). Address bytes 0-127 are not write protected and may cause diagnostic malfunctions if overwritten. The information stored in the EEPROM, including the organization and the digital diagnostic information, is defined in the Small Form-Factor document SFF-8472 Rev. 11.0, dated September, 2010. 9.1 Data Field Descriptions, and Serial ID Data and Map Address(1010000X) (A0h)
Address(1010001X) (A2h)
0
0 Alarm and Warning Limits Serial ID Information: 55
Defined by SFP MSA 95
95 OE Solution Specific Information
Reserved for External Calibration Constants Real Time Diagnostic Information
119 OE Solutions Specific
127
127
Information Non-volatile, customerwriteable, field-writeable
Reserved for SFP MSA
area 247 255
OE Solutions Specific Information
255
9.2 Serial ID and Map: page A0h Address 0 1 2 3 4 5 6 7 8 9 10
HEX 03 04 07 00 10 00 00 00 00 01 00
Name of Fields Identifier Ext. Identifier Connector Infiniband Compliance Reach Specifier SONET Gigabit Ethernet Fiber Channel link length Transmitter technology Transmission media Fiber Channel Speed
Description SFP+ GBIC/SFF function is defined by serial ID only LC Unallocated SONET IR-1/LR-1 compliant
Unallocated Unallocated Single Mode (SM)
14
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32-35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52-55 56 57 58 59 60 61 62 63 64
06 67 00 50 FF 00 00 00 00 4F 45 20 53 4F 4C 55 54 49 4F 4E 53 20 00 00 19 3A 52 44 50 58 30 53 5A 52 2D xx xx xx 20 30 31 2E Varies Note 1 Varies 04
Encoding
64B/66B
Nominal Bit Rate
10.30 Gbps
Length(9u)[km]
80 Km
Length(50u,OM2)[m] Length(62.5u,OM1)[m] Length(copper) Length(50u,OM3)[m]
Not Not Not Not
support support support support O E S O L U T I O N S
Vendor Name
Reserved Vendor OUI
Vendor PN
00 19 3A R D P X 0 S Z R xx = (5Ah for ST, 45h for ET, 49h for IT) xx=(31h:1, 32h:2,33h:3,34h:4,35h:5,36h:6) xx=(30h:0, 31h:1, 32h:2,33h:3,34h:4,35h:5,36h:6,37h:7, 38h:8, 39h:9) 0 1 . Varies
Vendor Rev.
Wavelength[nm] Wavelength(@10pm) CC_BASE Option Values Cooled Transceiver[2] Power Level[1] Linear Receiver Output[0]
Checksum over 0 to 62 Cooled Laser implementation
15
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
65
3A
66 67 68-83 84-91
00 00 Varies Varies
92
68
Option Values Rate Select[5] Tx Disable[4] TX Fault[3] SD[2] LOS[1] Bit Rate, max[%] Bit Rate, min[%] Vendor S/N Date Code Diagnostic Monitoring Type Digital diagnostic[6] Internally Cailbrated[5] Externally Calibrated[4] Average Power[3] Address change req[2] Enhanced Options Alarm/Warm Impl.[7] Soft TX Dis Control[6] Soft TX Fault monitor[5] Soft Rx LOS monitor[4] Soft RATE_SEL Control[3] App Select Control[2] Rate Select Control[1]
Rate Select[5] Tx Disable[4] TX Fault[3] LOS[1] Not Specified Not Specified Varies Varies Digital diagnostic[6] Internally Calibrated[5] Average Power[3]
Alarm/Warm Impl.[7] Soft TX Dis Control[6] Soft TX Fault monitor[5] Soft Rx LOS monitor[4]
93
F0
94
05
SFF-8472 Compliance
Rev 11.0 of SFF-8472
95
Varies 00 Varies 00 Varies
CC_EXT Vendor Specific OES'DATA Reserved OES'DATA
Check Sum Byte for Bytes 64 to 94
96-127 128-163 164-247 248-255
OES'DATA Reserved OES'DATA
Note 1. 16-bit integer value in nm with byte 60 as high byte, byte 61 as low byte. The fractional part of the wavelength in units of 0.01nm written in byte 62. Varies
9.3 Diagnostics
The enhanced digital diagnostics feature monitors five key transceiver parameters which are internally calibrated and should be read as absolute values. A2h address 96-97 98-99 100-101 102-103 104-105
Parameter Temperature Vcc Tx bias Tx power Rx Power
Calibration Internal Internal Internal Internal Internal
Accuracy +/- 3oC +/- 3% +/- 10% +/- 2dB +/- 2dB
Range Note 1 3.13 to 3.47 Note 2 -1 to +4Bm -23 to -6dBm
Note: 1) Junction temperature of temperature sensing device. Monitoring range is from -40oC to 125oC. 2) Specified by nominal value
16
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
9.4 Alarm Boundary Conditions 1) Transmitter Output Power and Receiver input power Tx Low Tx Alarm Tx High Model Name Warning Warning Low High -3 dBm 6 dBm 5.5 dBm RDPX0SZR-xxx -2.5 dBm
Rx Low Warning -25 dBm
Rx Alarm Low High -28 dBm -5 dBm
Rx High Warning -6 dBm
Bias Alarm Low High 40mA 130mA
Bias High Warning 120mA
2) Power Supply and Transmitter Bias Current Model Name RDPX0SZR-xxx
Vcc Low Warning 3.14V
Vcc Alarm Low High 2.97 3.63V
Vcc High Warning 3.47V
Bias Low Warning 50mA
3) Temperature Temperature Alarm Low High
Model Name
Temp. Low Warning
RDPX0SZR-Sxx
-5oC
-8oC
+73oC
+70 oC
RDPX0SZR-Exx
-5oC
-8oC
+88oC
+85oC
RDPX0SZR-Ixx
-40oC
-43oC
+88oC
+85 oC
Temp. High Warning
10. Regulatory Compliance RDPX0SZR comply with international Electromagnetic Compatibility (EMC) and international safety requirements and standards. EMC performance is dependent on the overall system design. The RDPX0SZR is lead-free and RoHS-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment..
11. Label
1. P/N : RDPX0SZR-xxx / 2. Bit rate , Reach , Wavelength : 10G 80km 1xxx.xxnm / 3. S/N
17
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
12. Ordering Information OES P/C
Model Name
Operating Case Temperature
Nominal Wavelength
Latch Color
C-band RDPX0SZR-Sxx
Gxx02
0oC to 70oC
DWDM
White
Application SONET/SDH & 10G GbE
(See Section 4.2)
C-band RDPX0SZR-Exx
Gxx10
-5oC to 85oC
DWDM
White
SONET/SDH & 10G GbE
(See Section 4.2)
C-band RDPX0SZR-Ixx
Gxx08
-40oC to 85oC
DWDM
White
SONET/SDH
(See Section 4.2)
Notice:
& 10G GbE
Distance
80km
80km
80km
This data sheet is subject to change at any time without notice.
Revision History Date
Rev. #
Description
12/13/2010
A.0
Initial Release
08/30/2011
A.1
Latch Color: White
Author(s) JSYU/KSP JSYU
Detailed specs for Rx Sensitivity, Path penalty, ONSR w.r.t BER 05/09/2012
A.2
Power consumption revised: 2.1W (Standard Temp)
JSYU
09/15/2012
A.3
Total current changed(Max. 650mA → 545mA)
JSYU
11/23/2012
A.4
Typo
JSYU
(Optical Extinction Ratio (Unfiltered) → Optical Extinction Ratio(filtered)) Datasheet correction (SONET OC-192 LR-2 / SDH L-64.2a → SONET OC-192 / STM-64 : P16L1-2A2) ET, IT added 06/26/2013
A.5
07/19/2013
Rev.A.6
Bias High Alarm/Warning changed(120mA/110mA→130mA/120mA)
JSYU
Total Current changed
JSYU
(ST : Max. 550mA → 650mA / ET,IT : 700mA → 750mA) Path Penalty changed : 2dB → 2.5dB 07/31/2013
Rev.A.7
Sensitivity and LOS De-assert changed (Max. -24dBm → Max. -23dBm)
JSYU
Path Penalty deleted Transmitter Output Power and Receiver input power changed
18
Rev. A.7, 07/31/2013
RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications
Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com.
OE Solutions America, Inc.
560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188 Fax:201-568-1177Tel: +1-201-224-2377, Fax: 1-949-272-3200
19
Rev. A.7, 07/31/2013