10gb/s Dwdm Sfp+ 80km Transceiver Rdpx0szr

   EMBED


Share

Transcript

RoHS Compliant 10Gb/s DWDM SFP+ 80km Transceiver RDPX0SZR-xxx Applications     Features SONET OC-192 / STM-64 : P16L1-2A2 10GBASE-ZR/ZW Ethernet 80km 10G FC G.709 OUT-2 Description  RoHS compliant  Support multi protocol from 9.9Gb/s to 11.3Gb/s OE Solutions’ Small Form Factor Pluggable (SFP+) transceivers are compatible with the Small Form Factor Pluggable 20pin MultiSource Agreement (MSA). The high performance cooled DWDM EML transmitter and high sensitivity APD receiver provide superior performance for SONET/SDH and Ethernet applications up to 80km optical links. Enhanced Digital Diagnostics functions are available via the 2-wire serial bus specified in the SFF-8472 Rev. 11.0. The transmitter and receiver features ac-coupled differential data inputs and outputs, and an LVTTL for Tx disable input and Tx fault output. Software TX disable is also implemented. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output.  Compliant with SFP+ MSA, SFF 8431 Rev. 4.1  Compliant with SFF 8432 Rev.4.3 mechanical dimension  Compliant with Digital diagnostic SFF-8472 Rev.11.0  Transmission distance of 80km over single mode fiber  C-band DWDM EML laser transmitter  LC duplex connector  Hot pluggable 20 pin connector  Single power supply voltage : +3.3V  Low power dissipation  Three optional operating temperature ranges : Option ST : 0°C to 70°C Option ET : -5°C to 85°C Option IT : -40°C to 85°C 1 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 1. Absolute Maximum Ratings Parameter Symbol Min. Typ. Max. Unit Notes Vcc_max 0 - 3.6 V - Operating Case Temperature Top -40 - 85 °C 1,3 Operating Relative Humidity RHop 5 - 90 % 2 Tst -40 - 85 °C 2 5 - 95 % 2 Absolute Supply Voltage Storage and Transportation Temperature Storage and Transportation Relative Humidity Notes: 1. Measured on top side front center of SFP module 2. Non-condensing 3.There are three options of operating maximum temperature: Option ST: standard temperature from 0oC to 70oC, Option ET: extended temperature from -5oC to 85oC Option IT: extended temperature from -40oC to 85oC 2. General Operating Conditions Parameter Symbol Min. Typ. Max. Unit Notes B 9.9 10.3 11.3 Gb/s - Dmax 80 - - km - Operating Voltage Vcc 3.14 - 3.46 V - - - 650 mA ST Power Supply Current ICC - - 750 mA ET, IT Total Power Consumption - - 2.1 W - ESD (High speed pins) - - 500 V 2 Bit Rate Maximum Transmission Distance Notes : 1. Supplies TEC, Current draw depends on Temperature 2. Human body model per JEDEC JESD22-A114-B, compliant with INF-8077i Rev. 4.5 August 31, 2005 2 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 3. Electrical Specifications 3.1 Transmitter Electrical Specifications (Over Operating Case Temperature and Power Supply Range) Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes Differential Input Impedance Rin 80 100 120 Ω - Differential Data Input Swing Vin,pp 180 - 800 mVp-p - Data Input Rise/Fall Time tr/tf 15 - 40 ps Tx Disable Voltage Vd 2.0 - Vcc+0.3 V 1 Tx Enable Voltage Ven 0 - 0.8 V - Tx Fault Output Low Vtfl - - 0.4 V - Tx Disable Assert Time T_off - - 100 s - Tx Enable Assert Time T_on - - 2 ms - Tx Fault Assert Time Tx_f_on - - 1 s - Tx Fault Reset Time Tx_reset 10 - - s - T_start_up_cooled - - 90 s - Initialization Time Note : 1. Vcc is the voltage of host board 3.2. Receiver Electrical Specifications (Over Operating Case Temperature and Power Supply Range) Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes B 9.9 10.3 11.3 GBd - Differential Output Impedance Rout 80 100 120 Ω - Differential Data Output Swing Vout 300 - 800 mVp-p - Data Output Rise/Fall Time tr/tf - - 45 ps - LOS Output High Voltage Vlosh Vcc-0.5 - Vcc+0.3 V 1 LOS Output Low Voltage Vlosl 0 - 0.4 V - T_los on/off - - 100/100 s/s - Data Rate LOS Assert/Deassert Time Delay Note : 1. Vcc is the voltage of host board 3 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 4. Optical Specifications 4.1 Transmitter Optical Specifications (Over Operating Case Temperature and Power Supply Range) Optical Characteristics Parameter Symbol Min. Laser Safety Class Typ. Max. Unit Class 1 according to IEC60825 Notes - λ 1529 - 1562 nm - Average Optical Output Power Pout -1 - 4 dBm 1 Optical Power Overshoot Pov - - 1 dB 2 Pout-off - - -40 dBm -  -8 - 8 GHz 3  Pout -1 - +1 dB - SMSR 35 - - dB 4 5 Optical Wavelength Optical power of OFF transmitter Spectral Width Optical Output Power Variation (with respect to BOL Tc=25C, and nominal power supply) Side Mode Suppression Ratio Wavelength BOL T -50 - +50 pm Deviation EOL a -100 - +100 pm ER 8.2 - - dB - Tr, Tf - - 35 ps - - - - - 6 Optical Extinction Ratio(Filtered) Optical Rise/Fall Time (20%-80%) Output Jitter Notes: 1. Average power measured at output 2. Defined as Peak power – Steady-state power (in dBm) when Tx-dis is de-asserted or when the module is hot plugged with Tx_dis in low state (Tx enabled). 3. Full spectral width (RBW=0.1nm) measured 15dB down from the maximum of center wavelength peak under full modulation condition 4. Ratio of the average output power in the dominant longitudinal mode to the power in the most significant side mode peak under full modulation condition 5. Deviation related to the ITU standardized wavelength. The EOL value is met as soon as the output average power is above 10% of the steady-state power. 6. The jitter performance meets Telcodia GR-253-Core and ITU-T Recommendations G.783, G813, G825 and G82511 with ITU-T 0.172(04/2005) for the measurement methods and the measurement equipment. Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. 4 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 4.2 ITU Channel and Wavelength Guide ITU Channel Frequency (THz) Wavelength (nm) ITU Channel Frequency (THz) Wavelength (nm) 39 193.9 1546.12 40 194.0 1545.32 17 191.7 1563.86 41 194.1 1544.53 18 191.8 1563.05 42 194.2 1543.73 19 191.9 1562.23 43 194.3 1542.94 20 192.0 1561.42 44 194.4 1542.14 21 192.1 1560.61 45 194.5 1541.35 22 192.2 1559.79 46 194.6 1540.56 23 192.3 1558.98 47 194.7 1539.77 24 192.4 1558.17 48 194.8 1538.98 25 192.5 1557.36 49 194.9 1538.19 26 192.6 1556.56 50 195.0 1537.40 27 192.7 1555.75 51 195.1 1536.61 28 192.8 1554.94 52 195.2 1535.82 29 192.9 1554.13 53 195.3 1535.04 30 193.0 1553.33 54 195.4 1534.25 31 193.1 1552.52 55 195.5 1533.47 32 193.2 1551.72 56 195.6 1532.68 33 193.3 1550.92 57 195.7 1531.90 34 193.4 1550.12 58 195.8 1531.12 35 193.5 1549.32 59 195.9 1530.33 36 193.6 1548.51 60 196.0 1529.55 37 193.7 1547.72 38 193.8 1546.92 5 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 4.3. Receiver Optical Specifications (Over Operating Case Temperature and Power Supply Range) Optical Characteristics Parameter Max. Unit Notes 1563 nm - - -23 dBm 1, 2 -6.0 - - dBm - - - - -27 dB - LOS Assert LOS_A -35 - - dBm - LOS De-assert LOS_D - - -23 dBm - - 0.5 - 5 dB - Optical Wavelength Average Rx Sensitivity@10Gb/s Maximum Input Power Receiver Reflectance LOS Hysteresis Notes : 31 Symbol Min. λ 1528 RSENS - Pol Typ. -12 1. Measured with a PRBS of 2 -1 at 1x10 BER and 8.2 dB extinction ratio, 1450ps/nm 2. Guaranteed after 80km transmission over the entire operating temperature range. 6 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 5. Pin Descriptions 20 Tx GND 1 Tx GND 19 TD- 2 Tx Fault 18 TD+ 3 Tx Disable 17 Tx GND 4 16 VccT 15 VccR 14 Rx GND 13 RD+ 12 11 5 SDA SCL 6 Mod_ABS 7 RS0 8 Rx_LOS RD- 9 RS1 Rx GND 10 Rx GND Top of Board Bottom of Board SFP Transceiver Electrical Pad Layout 7 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications Pin Descriptions (continued) Pin 1 2 3 4 5 6 Logic LVTTL-O LVTTL-I LVTTL-I/O LVTTL-I/O - Symbol Tx GND Tx Fault Tx Disable SDA SCL MOD_ABS 7 LVTTL-I RS0 8 LVTTL-O Rx LOS 9 10 11 12 13 14 15 16 17 18 19 20 LVTTL-I CML-O CML-O CML-I CML-I - RS1 Rx GND Rx GND RDRD+ Rx GND Vcc Rx Vcc Tx Tx GND TD+ TDTx GND Description Transmitter Ground Transmitter Fault Indication Transmitter Disable 2 wire Serial Interface Data Line 2 wire Serial Interface Clock Module Absent, connected to Tx GND or Rx GND in the module Rate Select 0, not used Receiver Loss of Signal Indication (In FC designated as Rx_LOS and in Ethernet designated as Signal Detect Bar Rate Select 1, not used Receiver Ground Receiver Ground Receiver Negative Data Out Receiver Positive Data Out Receiver Ground Receiver Power, 3.3V±5% Transmitter Power, 3.3V±5% Transmitter Ground Transmitter Positive Data In Transmitter Negative Data In Transmitter Ground Plug Seq. * 1 3 3 3 3 Notes 1 2 3 4 4 3 5 3 6 3 7 3 1 1 3 3 1 2 2 1 3 3 1 6 1 1 1 1 1 *Plug Seq. : Pin engagement sequence during hot plugging Notes : 1. The module ground contacts, Tx GND abd Rx GND, shall be isolated frim the module case, that is, frame ground. 2. Tx Fault is an open collector/drain output that shall be pulled up with a 4.7k ~ 10k on the host board. Pull up voltage between 2.0V and VccT + 0.5V. When high, output indicates a laser fault of some kind. When low, output indicates normal operation. The LD output is not turned off in case of Tx Fault 3. Tx Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the TRx with a 4.7k ~ 10k to VccT. 4. SDA and SCL should be pulled up with a 4.7k ~ 10k on the host board. The pull-up voltage shall be VccT. SCL is the clock line of 2-wire serial interface for serial ID. SDA is the data line of 2-wire serial interface for serial ID. 5. Mod_ABS is connected to Tx GND or Rx GND in the SFP+ module. The host may pull the contact up to Vcc on the host board with a resistor in the range 4.7 ~ 10k. Mod_ABS is asserted “high” when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF-8074i) this contact has the same function but is called MOD_DEF0. 6. RS0 and RS1 are module input rate select contacts and are pulled low to Tx GND with a >30k resistor in the module. RS0 is an input hardware contact which optionally selects the optical receive data path rate coverage for an SFP+ module. RS1 is an input hardware contact which optionally selects the optical transmit path data rate coverage for the SFP+ module. These contacts can also be used for AS0 and AS1 if implementing SFF8079. RS1 is commonly connected to Tx GND or Rx GND in the classical SFP modules. The host needs to ensure that it will not be damaged if this contact is connected to Tx GND or Rx GND in the module. For logical definitions of RS0/RS1, see Section 2.5 of SFF-8431 Rev. 2.1. 7. LOS is an open collector output. Shall be pulled up with a 4.7k ~ 10k on host board. Pull up voltage between 2.0 and VccR+0.3. Logic 0 indicates normal operation. 8 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 5. Outline Drawings Dimensions are in millimeters 9 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 6. PCB layout and Bezel recommendation Dimensions are in inches (millimeters) Notes : 1. Datum and basic dimensions established by customer. 2. Pads and vias are chassis ground, 11 locations 3. Thru holes, plating optional. 10 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 7. PCB layout and Bezel recommendation (continued) Notes : Thru holes, plating optional. Recommended Panel Opening 11 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 8. SFP+ Block Diagram, Power Supply Information and Host Board Interface 8.1 SFP+ Block Diagram Pin 3 10k Vcc Tx  Pin 18 Tx Disable Zin diff.= TD+ TOSA Pin 16 Laser 100 TDdriver Tx Fault 100 Pin 19 Pin 2 Pin 5 Management processor SCL EEPROM Pin 4 SDA Vcc Rx Pin 15 Pin 12 RD- TOSA Zout = 50 each arm Post amp. RD+ LOS Pin 13 Pin 8 Pin 10, 11, 14 Rx_GND Pin 1, 17, 20 Tx_GND RS0 Pin 7 Mod ABS Pin 6 RS1 Pin 9 12 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 8.2 Recommended Host Board Supply Filtering Network 1H Vcc Tx 0.1F Tx GND 1H Vcc +3.3V Vcc Rx 0.1F 10F 0.1F 10F Rx GND SFP+ Module HOST BOARD Host Board GND 8.3 SFP+ Host Board Interface Vcc 10k Vcc 10k Vcc 10k Vcc 10k Vcc 10k 1 Tx GND Tx GND 20 2 Tx Fault TD- 19 3 Tx Disable TD+ 18 4 SDA Tx GND 17 5 SCL Vcc Tx 16 6 Mod ABS Vcc Rx 15 7 RS0 Host board Device Refer to Section 8.2 RX GND 14 8 Rx LOS RD+ 13 9 RS1 RD- 12 10 Rx GND Differential 100(note 1) Rx GND 11 Host board Device Differential 100(note 1) SFP+ Module Note 1: Host board output device circuit in the transmitter side and host board input device circuit in the receiver should be carefully designed to meet 100ohm differential impedance matching. Also necessary is the dc bias circuit of each input and output by taking into account of ac coupling of data input ant output of SFP+ module. For the interface of host board devices, it is recommended to refer to the device vendor’s data sheet. 13 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 9. Digital Diagnostic Monitoring and Serial ID Operation The information is accessed through the pin 4 (SDA), and pin 5(SCL) of the module. The device address used to read the Serial ID data is 1010000X(A0h), and the address to read the diagnostic data is 1010001X(A2h). The EEPROM Write Protect pin is internally tied to ground with no external access, allowing write access to the customer-writable field (bytes 128-247 of address 1010001X). Address bytes 0-127 are not write protected and may cause diagnostic malfunctions if overwritten. The information stored in the EEPROM, including the organization and the digital diagnostic information, is defined in the Small Form-Factor document SFF-8472 Rev. 11.0, dated September, 2010. 9.1 Data Field Descriptions, and Serial ID Data and Map Address(1010000X) (A0h) Address(1010001X) (A2h) 0 0 Alarm and Warning Limits Serial ID Information: 55 Defined by SFP MSA 95 95 OE Solution Specific Information Reserved for External Calibration Constants Real Time Diagnostic Information 119 OE Solutions Specific 127 127 Information Non-volatile, customerwriteable, field-writeable Reserved for SFP MSA area 247 255 OE Solutions Specific Information 255 9.2 Serial ID and Map: page A0h Address 0 1 2 3 4 5 6 7 8 9 10 HEX 03 04 07 00 10 00 00 00 00 01 00 Name of Fields Identifier Ext. Identifier Connector Infiniband Compliance Reach Specifier SONET Gigabit Ethernet Fiber Channel link length Transmitter technology Transmission media Fiber Channel Speed Description SFP+ GBIC/SFF function is defined by serial ID only LC Unallocated SONET IR-1/LR-1 compliant Unallocated Unallocated Single Mode (SM) 14 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32-35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52-55 56 57 58 59 60 61 62 63 64 06 67 00 50 FF 00 00 00 00 4F 45 20 53 4F 4C 55 54 49 4F 4E 53 20 00 00 19 3A 52 44 50 58 30 53 5A 52 2D xx xx xx 20 30 31 2E Varies Note 1 Varies 04 Encoding 64B/66B Nominal Bit Rate 10.30 Gbps Length(9u)[km] 80 Km Length(50u,OM2)[m] Length(62.5u,OM1)[m] Length(copper) Length(50u,OM3)[m] Not Not Not Not support support support support O E S O L U T I O N S Vendor Name Reserved Vendor OUI Vendor PN 00 19 3A R D P X 0 S Z R xx = (5Ah for ST, 45h for ET, 49h for IT) xx=(31h:1, 32h:2,33h:3,34h:4,35h:5,36h:6) xx=(30h:0, 31h:1, 32h:2,33h:3,34h:4,35h:5,36h:6,37h:7, 38h:8, 39h:9) 0 1 . Varies Vendor Rev. Wavelength[nm] Wavelength(@10pm) CC_BASE Option Values Cooled Transceiver[2] Power Level[1] Linear Receiver Output[0] Checksum over 0 to 62 Cooled Laser implementation 15 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 65 3A 66 67 68-83 84-91 00 00 Varies Varies 92 68 Option Values Rate Select[5] Tx Disable[4] TX Fault[3] SD[2] LOS[1] Bit Rate, max[%] Bit Rate, min[%] Vendor S/N Date Code Diagnostic Monitoring Type Digital diagnostic[6] Internally Cailbrated[5] Externally Calibrated[4] Average Power[3] Address change req[2] Enhanced Options Alarm/Warm Impl.[7] Soft TX Dis Control[6] Soft TX Fault monitor[5] Soft Rx LOS monitor[4] Soft RATE_SEL Control[3] App Select Control[2] Rate Select Control[1] Rate Select[5] Tx Disable[4] TX Fault[3] LOS[1] Not Specified Not Specified Varies Varies Digital diagnostic[6] Internally Calibrated[5] Average Power[3] Alarm/Warm Impl.[7] Soft TX Dis Control[6] Soft TX Fault monitor[5] Soft Rx LOS monitor[4] 93 F0 94 05 SFF-8472 Compliance Rev 11.0 of SFF-8472 95 Varies 00 Varies 00 Varies CC_EXT Vendor Specific OES'DATA Reserved OES'DATA Check Sum Byte for Bytes 64 to 94 96-127 128-163 164-247 248-255 OES'DATA Reserved OES'DATA Note 1. 16-bit integer value in nm with byte 60 as high byte, byte 61 as low byte. The fractional part of the wavelength in units of 0.01nm written in byte 62. Varies 9.3 Diagnostics The enhanced digital diagnostics feature monitors five key transceiver parameters which are internally calibrated and should be read as absolute values. A2h address 96-97 98-99 100-101 102-103 104-105 Parameter Temperature Vcc Tx bias Tx power Rx Power Calibration Internal Internal Internal Internal Internal Accuracy +/- 3oC +/- 3% +/- 10% +/- 2dB +/- 2dB Range Note 1 3.13 to 3.47 Note 2 -1 to +4Bm -23 to -6dBm Note: 1) Junction temperature of temperature sensing device. Monitoring range is from -40oC to 125oC. 2) Specified by nominal value 16 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 9.4 Alarm Boundary Conditions 1) Transmitter Output Power and Receiver input power Tx Low Tx Alarm Tx High Model Name Warning Warning Low High -3 dBm 6 dBm 5.5 dBm RDPX0SZR-xxx -2.5 dBm Rx Low Warning -25 dBm Rx Alarm Low High -28 dBm -5 dBm Rx High Warning -6 dBm Bias Alarm Low High 40mA 130mA Bias High Warning 120mA 2) Power Supply and Transmitter Bias Current Model Name RDPX0SZR-xxx Vcc Low Warning 3.14V Vcc Alarm Low High 2.97 3.63V Vcc High Warning 3.47V Bias Low Warning 50mA 3) Temperature Temperature Alarm Low High Model Name Temp. Low Warning RDPX0SZR-Sxx -5oC -8oC +73oC +70 oC RDPX0SZR-Exx -5oC -8oC +88oC +85oC RDPX0SZR-Ixx -40oC -43oC +88oC +85 oC Temp. High Warning 10. Regulatory Compliance RDPX0SZR comply with international Electromagnetic Compatibility (EMC) and international safety requirements and standards. EMC performance is dependent on the overall system design. The RDPX0SZR is lead-free and RoHS-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.. 11. Label 1. P/N : RDPX0SZR-xxx / 2. Bit rate , Reach , Wavelength : 10G 80km 1xxx.xxnm / 3. S/N 17 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications 12. Ordering Information OES P/C Model Name Operating Case Temperature Nominal Wavelength Latch Color C-band RDPX0SZR-Sxx Gxx02 0oC to 70oC DWDM White Application SONET/SDH & 10G GbE (See Section 4.2) C-band RDPX0SZR-Exx Gxx10 -5oC to 85oC DWDM White SONET/SDH & 10G GbE (See Section 4.2) C-band RDPX0SZR-Ixx Gxx08 -40oC to 85oC DWDM White SONET/SDH (See Section 4.2) Notice: & 10G GbE Distance 80km 80km 80km This data sheet is subject to change at any time without notice. Revision History Date Rev. # Description 12/13/2010 A.0 Initial Release 08/30/2011 A.1 Latch Color: White Author(s) JSYU/KSP JSYU Detailed specs for Rx Sensitivity, Path penalty, ONSR w.r.t BER 05/09/2012 A.2 Power consumption revised: 2.1W (Standard Temp) JSYU 09/15/2012 A.3 Total current changed(Max. 650mA → 545mA) JSYU 11/23/2012 A.4 Typo JSYU (Optical Extinction Ratio (Unfiltered) → Optical Extinction Ratio(filtered)) Datasheet correction (SONET OC-192 LR-2 / SDH L-64.2a → SONET OC-192 / STM-64 : P16L1-2A2) ET, IT added 06/26/2013 A.5 07/19/2013 Rev.A.6 Bias High Alarm/Warning changed(120mA/110mA→130mA/120mA) JSYU Total Current changed JSYU (ST : Max. 550mA → 650mA / ET,IT : 700mA → 750mA) Path Penalty changed : 2dB → 2.5dB 07/31/2013 Rev.A.7 Sensitivity and LOS De-assert changed (Max. -24dBm → Max. -23dBm) JSYU Path Penalty deleted Transmitter Output Power and Receiver input power changed 18 Rev. A.7, 07/31/2013 RDPX0SZR-xxx DWDM SFP+ Transceiver Product Specifications Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com. OE Solutions America, Inc. 560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188 Fax:201-568-1177Tel: +1-201-224-2377, Fax: 1-949-272-3200 19 Rev. A.7, 07/31/2013