Preview only show first 10 pages with watermark. For full document please download

10gbps Tunable Sfp+ Optical Transceiver, Zr

   EMBED


Share

Transcript

10Gbps Tunable SFP+ Optical Transceiver, ZR, 80km Features • SFF-8431 MSA Revision 4.1 compliant • SFF-8690 MSA Revision 1.4 compliant • Full C-band tunable laser source • 50 GHz ITU channel spacing • 80 km reach • Operating temperature range of −5 to 70°C • Maximum power dissipation of 1.5 W • RoHS 6/6 compliant • Supports digital diagnostic monitoring Applications • Wide area networks (WAN) • Local area networks (LAN) • Storage area networks (SAN) • Ethernet switches and applications • FC switches and applications 48383 Fremont Blvd, Ste 116 Fremont, CA 94538, USA 510.687.0488 office 510.687.0098 fax titanphotonics.com Page 1 of 5 Version 2.0 All rights reserved. 1.1 Absolute Maximum Ratings Parameter Symbol Ratings Unit Storage temperature TST −40 to +85 °C Relative humidity RH 5 to 85 (noncondensing) % Static electrical discharge (human body model) ESD 1000 V VCCT, VCCR −0.3 to 4.0 V Pdth +4 dBm Power supply voltages Receive input optical power (damage threshold) 1.2 Operating Conditions Parameter Operating case temperature Power supply voltages Receiver wavelength range Symbol TOP Min Max Unit –5 +70 °C VCCT, VCCR λ 3.135 3.465 V 1528.38 1568.77 nm 1.3 Low-Speed Electrical and Power Characteristics Parameter Symbol Min. Typ. Max. Supply Currents and Voltages Voltage VCCT, VCCR 3.135 3.3 3.465 Unit Notes V With respect to GND Instantaneous operating peak current 600 mA Per supply pin VCCT and VCCR Sustained operating peak current 500 mA Per supply pin VCCT and VCCR 1.5 W Power dissipation Low-Speed Control and Sense Signals Outputs (Tx_Fault, Rx_LOS) Inputs (Tx_Disable, RS0, RS1) SCL and SDA inputs Pwr Compliant with SFF-8431 Compliant with SFF-8431 VOL −0.3 0.4 V IOH −50 37.5 μA Measured with a 4.7 kΩ load pulled up to VIL −0.3 0.8 V VIH 2 VCC3+0. 3 V VIL −0.3 VCC3*0. 3 V VCC3+0. 5 V VIH VCC3*0.7 At 0.7 mA VCChost1 Pulled up in module to VCCT Pulled up on host to Vcc_host 1 (typical 4.7 – 10 kΩ) 1. Vcc_host (min) 3.135 V – (max) 3.465 V 48383 Fremont Blvd, Ste 116 Fremont, CA 94538, USA 510.687.0488 office 510.687.0098 fax titanphotonics.com Page 2 of 5 Version 2.0 All rights reserved. 1.4 High-Speed Electrical Specifications Parameter Symbol Min. Typ. Max. Unit 0.10 UI (p-p) UJ DDPWS 0.023 0.055 UI (rms) TJ 0.28 UI (p-p) X1 0.12 UI X2 0.33 UI Transmitter Electrical Input Jitter from Host at B Data-dependent jitter DDJ Uncorrelated jitter Data-dependent pulse width shrinkage jitter Total 1jitter Eye mask Y1 95 UI (p-p) 350 100 mV Ω ps Total jitter TJ 0.70 UI 99% jitter J2 0.42 UI Eye mask X1 0.35 UI Y1 Mask hit ratio of 5x10−5 mV Y2 Input impedance, differential Limiting Module Receiver Electrical Output Jitter to Host at C Output rise and fall time (20% to 80%) 28 r, Tf Notes Notes 65 mV Y2 425 mV Rx input power at −23 dBm Mask hit ratio of 1x10−12 1.5 Optical Transmitter Characteristics Parameter Average optical power Extinction ratio Wavelength range Frequency range Frequency center spacing Frequency stability (BOL) Frequency stability (EOL) Channel tuning time Side mode suppression ratio Jitter generation 4 MHz to 80 MHz Symbol Pavg ER λc ƒc Min. –1 9.0 1528.38 191.1 Typ. 50 ƒc –1.5 ƒc –2.5 SMSR 35 20 kHz to 80 MHz Spectral width Relative intensity noise RIN Return loss 48383 Fremont Blvd, Ste 116 Fremont, CA 94538, USA 24 510.687.0488 office 510.687.0098 fax titanphotonics.com Max. 3 Unit Notes dBm dB 1568.77 nm 196.15 THz GHz ƒc +1.5 GHz ƒc +2.5 GHz 50 ms Any channel to any channel dB UI (p-p) 0.1 0.3 UI (p-p) 200 pm –130 dB/Hz At –20 dB, 0.01 nm RBW dB Page 3 of 5 Version 2.0 All rights reserved. 1.6 Optical Receiver Characteristics Parameter Receiver overload Receiver reflectance LOS assert LOS deassert LOS hysteresis Symbol Pmax Rrx Plos_on Plos_off Min. −7 Typ. −27 −33.5 −26 4 Rx Sensitivity 0.5 Data Rate (Gbps) 9.95, 10.3, 10.5 10.709 11.1 11.3 Rx Sensitivity 0 ps/nm BER 1x10−12 1x10−4 1x10−4 1x10−4 Max. –400 to +1450 ps/nm Max –23 –27 –27 –26.5 Max –21 –25 –25 –24 Unit dBm dB dBm dBm dB Unit dBm dBm dBm dBm 1.7 OSNR Characteristics with External CDR Data Rate (Gbps) 10.709 BER 1x10−4 1x10−4 10.709 11.1 Dispersion (ps/nm) Min Max 0 –18 –7 16 –18 –7 19 –18 –7 17 –18 –7 20 –400 to +1450 1x10−4 1x10−4 11.1 Rx Power Range (dBm) 0 –400 to +1450 OSNR (dB) 1.8 Digital Diagnostic Monitoring Accuracy Parameter Transceiver internal temperature Transceiver internal supply voltage Transmitter bias current TX output optical power RX input optical power 48383 Fremont Blvd, Ste 116 Fremont, CA 94538, USA 510.687.0488 office 510.687.0098 fax Symbol ΔDDM_Tint ΔDDM_Vint ΔDDM_Ibias ΔDDM_PTx ΔDDM_PRx Max. ±3 ±3 ±10 ±3 ±3 titanphotonics.com Unit °C % % dB dB Notes Between Rx overload and sensitivity levels Page 4 of 5 Version 2.0 All rights reserved. 1.9 Timing Requirement of Control and Status I/O Parameter Symbol Min. Max. Unit Notes Tx_Disable assert time t_off 100 µs Tx_Disable negate time t_on 50 ms Time to initialize 2-wire interface t_2w_start_up 300 ms From power on or hot plug Time to initialize t_start_up_cooled 90 s From power on or hot plug Tx_Fault assert Tx_Fault_on _cooled 50 ms Tx_Fault reset Tx_Fault_reset From occurrence of fault to assertion of Tx_Fault Time Tx_Disable must be held 10 µs Rising edge of Tx_Disable to fall of output signal below 10% of nominal Falling edge of Tx_Disable to rise of output signal above 90% of nominal high to reset Tx_Fault Rx_LOS assert delay t_loss_on 100 µs From occurrence of loss of signal to assertion of Rx_LOS RX_LOS negate delay t_loss_off 100 µs From occurrence of return of signal to negation of RX_LOS T-SFP+ Transceiver Mechanical Diagram Ordering information Part Number Product Description TSFP+C11H61 48383 Fremont Blvd, Ste 116 Fremont, CA 94538, USA 10Gbps Tunable SFP+ DWDM 50GHz C-band, C-temp 510.687.0488 office 510.687.0098 fax titanphotonics.com Page 5 of 5 Version 2.0 All rights reserved.