Transcript
PANTHER-11 YD serie 2 Purposefully designed as real industrial tools, all our generators in our product ranges dedicated to craftsmen, farmers and manufacturing professionals are certified as 'heavy duty', for intensive or normal use, or for emergencies or backup.
www.genset-gelec.com
DESCRIPTION
TYPE ESP power
kVA
11
PRP power
kVA
10
Rated power
kW
8
Rated voltage
V
230-400
Power factor
Cos Φ
0,8
rpm
1500
Rated speed TECHNICAL SPECIFICATIONS Number of phases
1/3
Rated frequency
Hz
50
Packing dimensions
mm
2020*1000*1250
kg
710
liter
100
G/weight Fuel tank capacity Starting system TYPE
ATS Switch UNIT
Number of cylinders
Bore stroke Displacement Fuel consumption rated Consumption at 70%
mm
80*90
L
1,357
Kg/kW.h
0,26
L/h
1,73 ATM
Max power speed in kW
1500r/m
10
Max power speed in Cv
1500r/m
13,6
dB(A)
≤70
Noise level (cocoon type) Compression ratio
22:01
Starting system Oil tank capacity TYPE
SWITCHBOARD
3
Inlet method
Electrical 12 v L UNIT
Type
ALTERNATOR
YD380D Water cooling, inline , 4-stroke, direct injection
Characteristics
DIESEL ENGINE
GENERATORS
UNIT
8 GELEC SLG164B
Rated power
kW/kVA
Rated current
A
8,8/11 48/16
Technology
Brushless (with AVR Stamford regulation)
Regulation
SX460
IP protection
23
Protection grade
H
The DEEPSEA controller series performs the functions of control and the automatic piloting of the diesel generator. This system also provides automatic start and shut down functions, data measurements and controls the alarms.