Preview only show first 10 pages with watermark. For full document please download

1100j-1150j H5 Framing Oct-2016.indd

   EMBED


Share

Transcript

1100J/1150J H5 Direct Vent ZC Framing Framing Dimensions Note: If using optional LDK Duct Kit, refer to LDK instructions packed with kits as framing is affected. Between underside of header and base of heater. Base of heater must be at finished hearth height. Increase cavity height accordingly. 1/2” thick non-combustible board required above engine (not supplied). See page NOTE: This unit requires a solid platform to support it. Combustible framing allowed beneath fireplace. Please note that any shims used underneath to raise the heater should be set back 1/2” behind front face of framing otherwise top face of shims may be visible. 40” * - Rear Vent: 16-1/2“ * ” 38 13-3/4” (349 mm) Approx. 9-1/4” (235 mm) from back surface of wall finish to front surface of appliance case w/no vent offset Min. 1” (25.4 mm) clearance to combustibles around vertical vent pipe - Top Vent: 17-1/2”, 20” when using LDK - May be reduced by thickness of additional non-combustible wall finish applied on top of 1/2” non-combustible board when using trims other than the 1130 Fixed Frame except when using LDK w/top vent Any surface directly in front of the unit which is at a height of less than 4” from the bottom of the unit must be non-combustible. 40” (1016 mm) to underside of combustible cavity 29” between underside of non-combustible board and base of heater 1/2” thick non-combustible board October 2016 1/2 PARTIAL SHELF, top outlet Framing with Partial Shelf—Top Outlet Miles Industries Ltd. • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1 Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333 www.valorfireplaces.com 1100J/1150J H5 Direct Vent ZC Framing October 2016 2/2 Venting Considerations—Vertical Takeoff *Notes—ALL venting considerations • Dimensions of venting are based on using Dura-Vent elbows. Elbow curve radius dimensions will vary when using other brands. In general, other brands have slightly bigger radius. • 3 inches clearance to combustibles required above horizontal pipe. Slope horizontal pipe upwards 1/4 inch per foot. 1 inch clearance required around sides and bottom of horizontal pipe and around vertical pipe. • When calculating effective pipe lengths subtract approximately 1-1/2 inch for pipe joint - for example, a 12 inches pipe section will add approximately 10-1/2 inches overall. 40” (1016 mm) to underside of combustible cavity Min 1” (25.4 mm) Required clearance to vertical pipe affects cavity depth Stand-off Approx. 39-1/4” (997 mm) *Approx. 49-3/4” (1266 mm) with 12” vent pipe 12” pipe section Fireplace Left Side View Venting Considerations—Horizontal Takeoff 1/2” (13 mm) beyond stand-off Fireplace Left side view 40” (1016 mm) to underside of combustible cavity Approx. 31” (787 mm) (1073 mm) *Approx. 42-1/4” *Approx. 52-3/4” (1340 mm) with 12” vent pipe 12” pipe section Miles Industries Ltd. • 190—2255 Dollarton Highway • North Vancouver, BC • V7H 3B1 Tel: 604.984.3496 or 1.800.468.2567 • Fax: 604.984.0246 or 1.800.268.0333 www.valorfireplaces.com