1112PS GLOBALCOM Power Supply Description Specifications The 1112PS is a rack mount power supply designed to provide 12V DC power to GLOBALCOM devices. The 1112PS ships with a single 1112PSM power supply module capable of delivering up to 37 Amps of 12V DC power to as many as eight (8) GLOBALCOM devices. This allows a single power supply to power multiple 1100ACS, 1200ACS, 1100MSG, 1200MSG, and 1300CNB units. Each unit is connected to a fused power output port on the rear of the 1112PS. The connectors are secured using the supplied cover plate to prevent unwanted disconnections. A second 1112PSM power supply module can be added to provide redundancy. If a module fails, the remaining module will assume the full load. A module can be replaced while the other module is left on without interrupting power to the system. A relay is provided that will de-energize if a power supply module has failed. This closure can be monitored through the supervision system. Electrical Supply Voltage.................................................................... 100 – 240 VAC Rated Input Current (per supply)........................................... 8 Amps Max Rated Output Voltage....................................................... +12VDC (±5%) Rated Output Current (total).........................................................37 Amps Rated Output Current (per output)..............................................4.6 Amps Relay Contact Rating...........................Form C, 1A 30VDC, 0.3A 125 VAC Fuse...................................................................5 Amp ATM-5 Blade Fuse Features • Small 1RU chassis provides a maximum of 37 Amps of 12VDC power • Individual power connections for up to eight (8) GLOBALCOM devices • Individual fuses protect each output Mechanical Height................................................................ 1.75”, 1 rack unit (4.4 cm) Width (without rack mount ears).......................................... 17” (43.2 cm) Depth................................................................................ 12.25” (31.1 cm) Recommended Mounting Depth.......................................... 18” (45.7 cm) Weight (with 1 x IED1112PSM module).............................. 13 lb. (5.9 kg) Weight (with 2 x IED1112PSM modules).......................... 15.6 lb. (7.1 kg) Environmental Operating Temperature Range................... 32 ˚F – 104 ˚F (0 ˚C – 50 ˚C) Storage Temperature Range..................-40 ˚F – 158 ˚F (-40 ˚C – 70 ˚C) Connectors Input..........................................................................IEC 60320 Type C-13 Output (typical of 8)................................ 2-pin Phoenix, 5.08mm spacing Fault Relay................................................ 3-pin Phoenix, 3.8mm spacing Compliance Safety UL60950-1 (Ed.2) Listed CAN/CSA C22.2 No. 60950-1-07 (Ed.2) Certified IEC 60950-1: 2005; AM 1:2009 EN 60950-1:2—6/A11:2009/A1:2010 • Universal input voltage for worldwide use CB Certificate • Rear security cover to prevent unwanted removal of any connections • Optional second 1112PSM power supply module to provide a redundant power solution • Fault relay provides notification if a power supply module fails FCC / EMC CFR, Title 47, Chapter I, Part 15 Subpart B ICES-003, Issue 4, 2004 AS/NZS CISPR 22: 2005 CISPR 22 (Ed.5): 2005 +A1 (EN 55022: 2006 +A1) CISPR 24 (Ed.1): 1997 +A1, A2 (EN 55024:1998 +A1, +A2) IEC 61000-3-2 (Ed.3): 2005, +A1,A2 (EN 61000-3-2:2006) IEC 61000-3-3 (Ed.2): 2008 (EN 61000-3-3:1995 +A1, +A2) ©2013 Innovative Electronic Designs, LLC DOC: 1203A REV: 04-13 Caution: Outputs are Not Isolated from each other or Nc C No ground FAULT RELAY 450 Watt power Supply 8 CH x 4.6 Amps Each Replace with equivalent type fuse only CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 8 F1 - 5Amp F2 - 5Amp F3 - 5Amp F4 - 5Amp F5 - 5Amp F6 - 5Amp F7 - 5Amp F8 - 5Amp + _ + _ + _ + _ + _ + _ + _ + _ IED1112PS Rear View with Single Power Supply Module IED1112PS Rear View with Redundant Power Supply Modules Application Example In the illustration below, a single 1112PS Power Supply is used to provide power to three different units located in the same equipment room. This installation utilizes two 1200ACS units operating in a LifeLine ACS configuration where the secondary unit will assume control in the event of a failure in the primary unit. The 1112PS includes a backup 1112PSM power supply module to provide redundant operation. An 1100MSG Message Server is included to provide an additional eight (8) channels of digital messaging. The 1112PS is capable of providing power to multiple units simultaneously. IED1112PS Power Supply To remote fault indicator panel or other monitoring system IED1200ACS Announcement Control System - Primary IED1200ACS Announcement Control System - LifeLine IED1100MSG Message Server Innovative Electronic Designs, LLC 9701 Taylorsville Road Louisville, KY 40299, USA +1.502.267.7436 phone +1.502.267.9070 fax www.iedaudio.com © Innovative Electronic Designs LLC. All Rights Reserved. IED, 500ACS, and 500ACS Announcement Control System are Registered Trademarks of Innovative Electronic Designs LLC. Atlas Sound is a Registered Trademark of Atlas Sound L.P. CobraNet is a trademark of Cirrus Logic. All other trademarks are the property of their respective owners and no endorsement is implied. Due to continual product development, specifications are subject to change without notice.