Transcript
Description :
UPS rack 700VA 5 or 10 minutes
Type : ALMI 115-700-10’-R (On-line technology) Model : SEEL010797 / SEEL011779 / SEEL012030 Other type :
115-700VA-5min. or 230Vac-700VA-5min
Introduction : The ENAG UPS rack presents numerous decisive advantages compared to conventional equipment : • Standard charger and inverter integrated modules • Universal input voltage : 90 to 264Vac • Operation possible without batteries Model Input voltage Output voltage Back-up SUB-D 9 Connection
SEEL010797
SEEL011779 SEEL012030 90 to 264 Vac 115Vac / 60Hz 230Vac /50Hz 10 min. 5 min. 5 min. No Yes Yes NEMA (2) IEC 320 (1)
• Wide range of operating temperature • Dimensions : 19’’ rack 2U
Electrical characteristics : Input : -
Voltage : 230 Vac single phase +/- 10%.
Frequency : 50 Hz +/- 1%.
Output : -
Voltage : 230 Vac single phase +/- 10%.
-
Power : 400VA cosφ 0.8 to 1.
-
Autonomy : 5 minutes at full load.
Frequency : 50 Hz +/- 1%.
Protections : -
Input and output protected by fuses and differential switch.
-
Protections against overload and over temperature.
-
Input and outputs EMC filters.
Operating controls : -
On the front side : o o o
-
On-Off switch. 3 LED lights: « in operation »,« in autonomy » and « low battery ». A cut-off push button with fault sound signal.
On the back side : o o o o
A male base type IEC 320. female bases SUB D9 with potential free contacts (according to model). A circuit-breaker.
Presentation : Metal case rack 19’’. Intended to be integrated in a 19’’bay , it can be fixed on the front side and using inserts located on the sides Handle on the front for extraction of the rack. Strengthened equipment (shocks and vibrations)
Size and weight : Height = 2U,
Width =19’’,
Depth = 550 mm.
Weight < 30 Kg.
Climatic specifications : Operating temperature : - 20° C to + 55° C, Storage temperature : - 40° C to + 70° C Humidity : 90 % without condensation (relative humidity at 35°C) Ingress protection : IP20.
Applicable standards : Security : NF 15100./EN60950 EMC : EN 61000-6-2 / EN 61000-6-4 / EN 55022 / 61000-3-2 EC marking.
Miscellaneous : Technical user manual, corrective and preventive maintenance manual Other voltages upon request The information contained in this publicity leaflet are not of a contractual nature. ENAG reserves the right to amend the technical details of its products without advance notice. Please consult us before installing the units
FC-ALMI-RACK-115-700-10MN-EN-A
ENAG S.A.S. - 31 rue Marcel Paul - Z.I. Kerdroniou Est - 29000 Quimper – France Tel : + 33 2 98 55 51 99 – Fax : + 33 2 98 55 51 67 - E-mail :
[email protected] – Site : www.enag.fr