Preview only show first 10 pages with watermark. For full document please download

120 32 Large Air Flow And High Static Pressure Energy-saving

   EMBED


Share

Transcript

Blower Blower 120mm B120 ■ Features Large air flow and high static pressure ・Maximum air flow : 1.6 m3/min(56.5 CFM) ・Maximum static pressure : 1250 Pa(5.02 inch H2O) Energy-saving ・Power consumption: 26.4 W* Low Sound Pressure Level ・Sound Pressure Level: 62 dB(A) * When model No. 9BFB24P2H003 is used. 120mm×32mm ■ Specifications Model No. Rated Voltage [V] Operating Voltage Range [V] PWM Rated Current Rated Input Rated Speed Duty Cycle -1 Note1,2) [%] [A] [W] Air Flow Static Pressure SPL [min ] [m3/min] [CFM] [Pa] [inchH2O] [dB(A)] 9BFB12P2H003 12 10.8 to 13.2 100 2.3 27.6 3,750 1.6 56.5 1,250 5.02 62 9BFB24P2H003 24 21.6 to 26.4 100 0 1.1 0.12 26.4 2.88 3,750 1,300 1.6 0.46 56.5 16.2 1,250 43 5.02 0.17 62 41 Operating Life Temperature Expectancy [℃] [h] −20 to +70 40,000 Note1 : PWM Frequency:25kHz Note2 : 9BFB12P2H003 does not rotate when PWM duty cycle is 0%. ■ Common Specifications □ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame, Impeller : Plastics (Flammability: UL94V-0) □ Life Expectancy ・・・・・・・・・・・・・・・・・・・ Varies for each model □ Dielectric Strength ・・・・・・・・・・・・・・・・ 50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) □ Sound Pressure Level (SPL) ・・・・・・・・ Expressed as the value at 1m from air inlet side □ Operating Temperature ・・・・・・・・・・・・ Varies for each model (Non-condensing) □ Storage Temperature ・・・・・・・・・・・・・・ −30℃ to +70℃ (Non-Condensing) +Red ○ ーBlack Sensor: Yellow Control: Brown □ Lead Wire ・・・・・・・・・・・・・・・・・・・・・・・・ ○ □ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Approx. 340g 120mm (L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state) □ Motor Protection System ・・・・・・・・・・ Current blocking function and Reverse polarity protection B120 ■ Air Flow - Static Pressure Characteristics ・ Operating Voltage Range ・ PWM Duty Cycle (inch H2O)(Pa) (inch H2O)(Pa) DC 12V 1600 6.0 4.0 3.0 1200 PWM Duty Cycle 1000 100% 800 600 50% 2.0 400 1.0 0 5.0 1.0 0.5 0 3.0 30 20 10 40 60 50 600 400 0 70(CFM) (inch H2O)(Pa) → Static Pressure → Static Pressure 1200 PWM Duty Cycle 1000 100% 800 600 0 50% 0 1.0 0.5 10 5.0 4.0 3.0 20 30 40 50 60 24V 1200 21.6V 1000 800 600 400 0 2.0(m3/min) 1.5 70 (CFM) 2.0 1.0 0% 0 60 26.4V 1400 200 50 PWM Duty 100% 1600 6.0 400 40 9BFB12P2H003 DC 24V 2.0 30 20 9BFB12P2H003 1400 1.0 10 2.0(m3/min) 1.5 1.0 0.5 0 0 6.0 3.0 200 → Air Flow 1600 4.0 800 → Air Flow (inch H2O)(Pa) 5.0 1000 2.0 2.0(m3/min) 1.5 12V 1200 10.8V 4.0 1.0 200 0 13.2V 1400 → Static Pressure → Static Pressure 1400 5.0 PWM Duty 100% 1600 6.0 70 (CFM) 200 0 → Air Flow 1.0 0.5 0 10 20 30 40 2.0(m3/min) 1.5 50 60 70(CFM) → Air Flow 9BFB24P2H003 9BFB24P2H003 ■ PWM Duty - Speed Characteristics Example Voltage:DC12V PWM Frequency:25kHz 7000 7000 7,000min -1 -1 Voltage:DC24V PWM Frequency:25kHz When fan operates at 800 Pa static pressure 6000 6000 5,000min-1 When fan operates at 350 Pa static pressure 4000 3,750min-1 Free air, when fan operates at no static pressure 3000 1000 1000 PWM Duty Cycle(%) 9BFB12P2H003 3,750min-1 Free air, when fan operates at no static pressure 3000 2000 100 When fan operates at 500 Pa static pressure 4000 2000 00 5,000min-1 5000 Speed(min-1) Speed(min-1) 5000 0 7,000min-1 When fan operates at 850 Pa static pressure 0 0 PWM Duty Cycle(%) 9BFB24P2H003 100 120×32mm ■ PWM Input Signal Example VIH=4.75V to 5.25V Input Signal Wave Form VIL=0V to 0.4V T1 T ×100 1 PWM Frequency 25(kHz)= T PWM Duty Cycle(%)= VIH Source Current : 1mA Max. at control voltage 0V Sink Current : 1mA Max. at control voltage 5.25V (Rated Voltage 12V fan) VIL 3mA Max. at control voltage 5.25V (Rated Voltage 24V fan) T1 Control Terminal Voltage : 5.25V Max. (Open Circuit) T When the control lead wire is no connecting, the speed is the same speed as at 100% of PWM cycle. This fan speed should be controlled by PWM input signal of either TTL input or open collector, drain input. ■ Connection Schematic DC fan input voltage ○ + PWM Input Signal Inside of DC fan Control Isource Isink − ○ ■ Specifications for Pulse Sensors Output circuit : Open collector Inside of DC fan + ○ Sensor Rated Voltage 12V fan VCE=+13.8V MAX. Ic=10mA MAX.[VOL=VCE(SAT)=1.0V MAX.] Rated Voltage 24V fan VCE=+30V MAX. Ic=10mA MAX.[VOL=VCE(SAT)=0.6V MAX.] Pull-up resistor +13.8V MAX.(Rated Voltage 12V fan) +30V MAX.(Rated Voltage 24V fan) Ic=10mA MAX. Sensor output − ○ Output waveform (Need pull-up resistor) T1∼4≒(1/4)T0 In case of steady running (One revolution) N=Fan speed(min-1) T0 T1 VOH VOL 0V T2 T1∼4≒(1/4)T0=60/4N(sec) T3 T4 (56) 5 3-R 105±0.3 (63.8) 92±0.3 92±0.3 (71.7) 88±0.3 65±0.3 (63.7) (15) 120±1 120±1 (2) (22) 32±1 (28) (0.8) (2) (2) 0 +3 0 0− 30 ) (10 Lead Wire AWG24 UL1430 (7.5) ■ Dimensions (unit : mm) .5 (5) Air Flow Direction 0 .2 7± ±0 φ7 -φ4.3 9 (7.5) 105±0.3 88±0.3 (15) 90±0.3 (22.5) Rotating Direction Notice ●The products shown in the catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 1-15-1, Kita-otsuka, Toshima-ku,Tokyo 170-8451, Japan. PHONE :+ 81 3 3917 5151 http://www.sanyodenki.co.jp CATALOG NO. 952-1 ‘10.10