Preview only show first 10 pages with watermark. For full document please download

120

   EMBED


Share

Transcript

DC fan DC fan 120mm 120 ■ Features High Static Pressure Maximum static pressure is increased by approx. 3.6times compared with our conventional product*1. Energy-saving Power consumption is reduced by approx. 11% compared with our conventional product *1,2. *1: Our conventional product is 120 x 120 x 38 mm thick. San Ace 120 GVtype, Model No. 9GV1248P1J01. *2: When air flow and static pressure is almost identical. 120×120×38mm HV type ■ Specifications Model No. Operating Rated Voltage Voltage Range [V] [V] 9HV1248P1G001 48 36 to 60 9HV1248P1H001 48 36 to 60 PWM Duty Cycle [%]Note1) 100 0 100 0 Rated Current Rated Input [A] [W] 2.0 0.23 1.4 0.23 96 11 67 11 Rated Speed [min-1] 11,500 3,800 10,000 3,800 Max. Air Flow Max. Static Pressure [m3/min] [CFM] [Pa] [inchH2O] 8.3 2.7 7.2 2.7 293 95 254 95 1,300 161 1,050 161 5.22 0.65 4.22 0.65 SPL [dB(A)] 75 46 72 46 Operating Temperature [℃] Note2) Expected Life [h] −10 to +70 40,000/60℃ (70,000/40℃) Note1 : PWM Frequency : 25kHz Note2 : Expected life at 40 degreeC ambient is just reference value. ■ Common Specifications □ Material ・・・・・・・・・・・・・・・・・・・・・・・・・・ Frame: Aluminum, Impeller: Plastics (Flammability: UL94V-1) □ Expected Life ・・・・・・・・・・・・・・・・・・・・・ Varies for each model □ Dielectric Strength ・・・・・・・・・・・・・・・・ 50/60 Hz, 500VAC, 1 minute (between lead conductor and frame) □ Sound Pressure Level (SPL) ・・・・・・・・ Expressed as the value at 1m from air inlet side □ Operating Temperature ・・・・・・・・・・・ Varies for each model (Non-condensing) □ Storage Temperature ・・・・・・・・・・・・・ −30℃ to +70℃ (Non-Condensing) +red ○ ーblack Sensor: yellow Control : brown □ Lead Wire ・・・・・・・・・・・・・・・・・・・・・・・・ ○ □ Mass ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ Approx. 460g 120mm (L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state) □ Motor Protection System ・・・・・・・・・・ Current blocking function and Reverse polarity protection 120 ■ Air Flow - Static Pressure Characteristics ・ PWM Duty Cycle ・ Operating Voltage Range (inch H2O)(Pa) 5 PWM Duty Cycle 100% 1,200 4 1,000 3 800 600 2 50% 400 1 0 4 0 1 0 2 3 50 4 100 5 150 6 7 8 1000 800 600 400 0 9 (m3/min) 200 0 1 0 300 (CFM) 200 250 60V 1,200 2 1 3 48V 36V 0% 200 PWM Duty Cycle 100% 1,400 → Static pressure → Static pressure 5 (inch H2O)(Pa) DC 48V 1,400 2 50 3 4 100 5 6 150 200 7 8 → Air flow → Air flow 9HV1248P1G001 9HV1248P1G001 (inch H2O)(Pa) (inch H2O)(Pa) DC 48V 1,200 1,200 4 1,000 4 1,000 9 (m3/min) 250 300 (CFM) PWM Duty Cycle 100% 3 → Static pressure → Static pressure 60V PWM Duty Cycle 100% 800 600 2 400 1 0 50% 0 2 1 0 50 3 100 4 150 5 6 200 7 8 (m3/min) 250 (CFM) 48V 800 600 2 400 1 0% 200 3 36V 0 200 0 0 2 1 50 3 100 4 150 5 6 200 7 8 (m3/min) 250 (CFM) → Air flow → Air flow 9HV1248P1H001 9HV1248P1H001 ■ PWM Duty - Speed Characteristics Example Voltage:DC48V PWM Frequency:25kHz 12,000 Voltage:DC48V PWM Frequency:25kHz 11,500min-1 10,000min-1 10,000 10,000 Speed(min-1) Speed(min-1) 8,000 8,000 6,000 4,000 6,000 4,000 3,800min-1 3,800min -1 2,000 2,000 0 0 PWM Duty Cycle(%) 9HV1248P1G001 100 0 0 PWM Duty Cycle(%) 9HV1248P1H001 100 120mm sq.×38mm ■ PWM Input Signal Example VIH=4.75V to 5.25V Input Signal Wave Form VIL=0V to 0.4V VIH PWM Duty Cycle(%)= T1 ×100 T PWM Frequency 25(kHz)= 1 T Source Current(Isource) : 1mA Max. at control voltage 0V VIL Sink Current(Isink) : 1mA Max. at control voltage 5.25V Control Terminal Voltage : 5.25V Max. (Open Circuit) T1 When the control lead wire is open, speed is same as one at 100% PWM duty cycle. T This fan speed should be controlled by PWM input signal of either TTL input or open collector, drain input. ■ Connection Schematic DC fan input voltage Inside of DC fan + ○ PWM Input Signal Isource Isink − ○ ■ Specifications for Pulse Sensors VCE=+60V MAX. Ic=10mA MAX.[VOL=VCE(SAT)=0.6V MAX.] Output circuit : Open collector Inside of DC fan + ○ Sensor Pull-up resistor Pull-up voltage Ic Sensor output (VCE) − ○ Output waveform (Need pull-up resistor) T1∼4≒(1/4)T0 In case of steady running (One revolution) N=Fan speed(min-1) T0 T1 VOH VOL 0V T2 T1∼4≒(1/4)T0=60/4N(sec) T3 T4 ■ Dimensions (unit : mm) 8-Ø4.5±0.3 104.8±0.3 120±0.8 Mounting Hole +30 300 0 (10) 104.8±0.3 120±0.8 Lead Wire AWG24 UL1430 Rotating Direction 6.5±0.3 6.5±0.3 3.5±0.3 3.5±0.3 38±0.5 Air Flow Direction ■ Reference dimension of mounting holes and vent opening (unit : mm) Inlet Side, Outlet Side 104.8±0.3 117 104.8±0.3 φ 13 0 4-φ4.5 117 Notice ●The products shown in the catalog are subject to Japanese Export Control Law. Diversion contrary to the law of exporting country is prohibited. ●To protect against electrolytic corrosion that may occur in locations with strong electromagnetic noise, we provide fans that are unaffected by electrolytic corrosion. 1-15-1, Kita-otsuka, Toshima-ku,Tokyo 170-8451, Japan. PHONE :+ 81 3 3917 5151 http://www.sanyodenki.com The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. Specifications are subject to change without notice. CATALOG NO. C1014B001 ‘12.10