Transcript
XSP Series XSPWA02
XSPW™ Wall Pack Luminaire – Wall Mount – Type II Product Description XSPW™ has a slim, low profile design intended for outdoor wall mounted applications. The rugged lightweight aluminum housing and mounting box are designed for installation over standard and mud ring single gang J-Boxes. The luminaire allows for through-wired or conduit entry from the top, bottom, sides and rear. The housing design is intended specifically for LED technology including a weathertight LED driver compartment and thermal management. Optic design features industry-leading NanoOptic Precision Delivery Grid™ system in multiple distributions.
Performance Summary Utilizes BetaLED® Technology NanoOptic® Precision Delivery Grid™ optic
9.3" (236mm)
Made in the U.S.A. of U.S. and imported parts CRI: Minimum 70 CRI
CCT: 4000K (+/- 300K), 5700K (+/- 500K) Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish 12" (305mm)
4.8" (122mm)
3.8" (97mm)
Multi-Level Sensor (K Option Only)
Click below to select Quick Ship products
Ordering Information
BXSPWA02FG-UZ BXSPWA02FC-UZ BXSPWA02FC-US BXSPWA02FG-US For full list of Cree Quick Ship products visit www.cree.com/lighting/quickship
Example: XSPWA02FC-US XSPW
A
0
2
Product
Version
Mounting
Optic
Modules
Input Power Designator
–
Voltage
Color Options
Options
XSPW
A
0 Wall
2 Type II
F 4000K M 5700K
C 42W G 25W
US * Canada
U Universal 120–277V 1 120V 2 208–277V
Z Bronze S Silver T Black B Platinum Bronze W White
Y 0–10V Dimming - Control by others - Available with Input Power Designator C only - Refer to dimming spec sheet for details P Photocell - Not available with all K options. - Must specify voltage other than U K Multi-Level - Refer to ML spec sheet for details - Available with Input Power Designator C only
† See www.cree.com/lighting/products/warranty for warranty terms
Rev. Date: 06/10/14
US: www.cree.com/lighting T (800) 236-6800
F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234
F (800) 890-7507
XSPWA02 Product Specifications
Photometry
CONSTRUCTION & MATERIALS • Slim, low profile design
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified laboratory.
• Luminaire housing specifically designed for LED applications with advanced LED thermal management and driver
2302
150°
150°
40' 30' 20' 10' 30'
1727
• Luminaire mounting box designed for installation over standard and mud ring single gang J-Boxes
120°
120°
.1 .2 .5 1
0'
90°
90°
3.0
2
5
0m
CURB LINE
10'
• Conduit entry from top, bottom, sides, and rear
3.0 .1
20'
• Designed and UL approved for easy through-wiring 60°
• Designed for downlight applications only • Exclusive Colorfast DeltaGuard® finish features an E-coat epoxy primer with an ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Bronze, silver, black, white, and platinum bronze are available
6.1
6.1 3.0 0m 3.0 6.1
9.1 12.2
9.1
Position of vertical plane of maximum candlepower.
Candlepower Trace: Vertical plane through horizontal angle of maximum candlepower.
CESTL Test Report #: 2014-0017 BXSPWA*2FG-US Initial Delivered Lumens: 2,739
ELECTRICAL SYSTEM • Input Voltage: 120–277V, 50/60Hz, Class 2 output
30' 12.2 9.1
60°
30°
9.1
60˚
6.1
10'
576
• Secures to wall with four 3/16" (5mm) screws (by others)
10' 20' 30' 40'
20'
1151
• Luminaire can also be direct mounted to a wall and surface wired
0'
BXSPWA*2FC-US Mounting Height: 10' (3.0m) Initial Delivered Lumens: 3,819 Initial FC at grade
• Power Factor: > 0.9 at full load • Total Harmonic Distortion: < 20% at full load
40' 30'
30'
20'
10'
0'
10'
20'
30'
40'
9.1
• Integral 10kV surge suppression protection standard
20'
6.1
• To address inrush current, slow blow fuse or type C/D breaker should be used
10'
3.0
60˚
.1 .2 .5 1 2
5
0'
REGULATORY & VOLUNTARY QUALIFICATIONS • cULus Listed
10'
20' 12.2
• Suitable for wet locations
0m
CURB LINE
3.0 6.1
9.1
6.1
3.0
0m
• Enclosure rated IP66 per IEC 60529
3.0
6.1
9.1
12.2
Position of vertical plane of maximum candlepower.
• Product qualified on the DesignLights Consortium ("DLC") Qualified Products List ("QPL") • 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2
BXSPWA*2FG-US Mounting Height: 10' (3.0m) Initial Delivered Lumens: 2,529 Initial FC at grade
• Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient salt fog conditions as defined in ASTM Standard B 117 • Meets Buy American requirements within ARRA
Luminaire Weight Weight 9.5 lbs (4.3kg)
Lumen Output, Electrical, and Lumen Maintenance Data Type II Distribution 5700K
4000K
Total Current
Initial Delivered Lumens*
BUG Ratings** Per TM-15-11
Initial Delivered Lumens*
BUG Ratings** Per TM-15-11
System Watts 120–277V Nominal
C
4,109
B1 U0 G1
3,819
B1 U0 G1
42
.35
.20
.18
.15
99%
G
2,722
B1 U0 G1
2,529
B1 U0 G1
25
.21
.12
.10
.09
100%
Input Power Designator
120V
208V
240V
277V
50K Hours Projected Lumen Maintenance Factor @ 15˚C (59˚F)***
* Actual production yield may vary between -4 and +10% of initial delivered lumens ** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit www.iesna.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf *** For recommended lumen maintenance factor data see TD-13. Projected L70 based on 11,088 hours LM-80-08 testing: > 150,000 hours
© 2014 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. See www.cree.com/patents for patents that cover these products. Cree®, the Cree logo, BetaLED®, NanoOptic®, the BetaLED Technology logo, and Colorfast DeltaGuard® are registered trademarks, and the XSPW™ and Precision Delivery Grid™, and the Quick Ship logo are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. The DesignLights Consortium logo and the DLC QPL Listed logo are registered trademarks of Northeast Energy Efficiency Partnerships, Inc.
US: www.cree.com/lighting
T (800) 236-6800
F (262) 504-5415
Canada: www.cree.com/canada
T (800) 473-1234
F (800) 890-7507