Transcript
1.25 Gigabit Ethernet-Single Mode Transceiver SFP, D u p l e x LC C o n n e c t o r , C W D M LD fo r Si n g l e M o d e Fi b e r , R o H S C o m p l i a n t Digital Diagnostics Functions, Power Budget 30dB
F e atu r e s • • • • • • •
Applications
•
•
CWDM
•
•
Gigabit Ethernet Links
•
•
Fibre Channel Links at 1.06 Gbps
•
High Speed Backplane Interconnects
•
Switched Backbones
• •
RoHS Pb
CWDM 8 wavelengths Transmitter APD Receiver Data Rate: 1.25Gbps, NRZ Single +3.3V Power Supply RoHS Compliant and Lead-free AC/AC Differential Electrical Interface Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP) Compliant with SFF-8472 Digital Diagnostic Monitoring Interface Duplex LC Connector Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps Compliance with ANSI specifications for Fibre Channel applications at 1.06 Gbps Eye Safety Designed to meet Laser Class 1 comply with EN60825-1
D e scr iption The CT-1250TSP-CB9L-D series from Coretek Opto Corp. are the high performance and cost-effective modules for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates with +3.3V power supply. The module is intended for single mode fiber, operates at a nominal wavelength of CWDM and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module is integrated digital diagnostics functions via an I2C serial interface. The module is a duplex LC connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s long reach applications. The characteristics are performed in accordance with ITU-T G.694.2 and G.695.
E MC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields.
E y e S af e ty The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1.
Coretek Opto Corp.
http://www.coretek.com.tw
1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105
Page 1 of 5 10/03/2006 VersionA
1.25 Gigabit Ethernet-Single Mode Transceiver Pr od u ct I nf or m ation Model Number
Wavelength
Latch Color
1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm
Gray Violet Blue Green Yellow Orange Red Brown
CT-1250TSP-CB9L-D
Operating Voltage & SD Output
Distance
Output Power
Sensitivity
3.3V TTL AC/AC
100 km
0 ~ +5 dBm
-30 dBm
A B S O L U T E M A X R A T IN G S PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current
SYMBOL TS VCC --IS
MIN -40 0 0
SYMBOL TA VCC VID
MIN. 0 3.1 300
MAX 85 6 Vcc 300
UNIT V V mA
NOTE
O P E R A T IN G C O N D IT IO N S PARAMETER Case Operating Temperature Supply Voltage Data Input Voltage Swing
TYP.
MAX. 70 3.5 1860
UNIT V mV
NOTE
E L E C T R IC A L C H A R A C T E R IS T IC S PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage
Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High
Coretek Opto Corp.
http://www.coretek.com.tw
SYMBOL
MIN
MAX
UNIT
ICCT VIL VIH VOL VOH
0 2.0 0 2.0
200 0.8 Vcc 0.8 Vcc
mA V V V V
ICCR VOD VOL VOH VIL VIH
0.4 0 2.0 -0.6 Vcc 0.7
100 1.3 0.8 Vcc Vcc 0.3 Vcc + 0.5
mA V V V V V
1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105
NOTE
Page 2 of 5 10/03/2006 VersionA
1.25 Gigabit Ethernet-Single Mode Transceiver T R A N S M I T T E R E L E C T R O -O P T I C A L C H A R A C T E R I S T I C S PARAMETER Optical Output Power Extinction Ratio
SYMBOL Po ER
Center Wavelength
c
Spectral Width (-20dB) Side Mode Suppression Ratio RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye
MIN 0 9 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5
SMSR RIN tr tf
30
TYP.
MAX 5
1470 1490 1510 1530 1550 1570 1590 1610
1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 1
-120 260 260 Compliant with IEEE802.3z/D5.0
UNIT dBm dB
NOTE 1
nm
nm dB dB/Hz ps ps
2 2
R E C E I V E R E L E C T R O -O P T I C A L C H A R A C T E R I S T I C S PARAMETER Maximum Input Optical Power Minimum Input Optical Power Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency
LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis
SYMBOL Pmax Pmin ORL --- PA PD PD -PA
MIN -8
TYP.
MAX -30 1620
1260 12
1500
-42
-29
0.5
UNIT dBm dBm nm dB MHz dBm dBm dB
NOTE 3 3
Notes: 1. Measured average power coupled into 9/125m single mode fiber. 2. These are 20-80% values. 3. Measured with 27-1 PRBS at BER<10-12
T IM IN G C H A R A C T E R IS T IC S PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off)
Coretek Opto Corp.
http://www.coretek.com.tw
SYMBOL t_off t_on t_init t_fault t_reset tA,RX_LOS tD,RX_LOS
MIN
10
TYP.
MAX 10 1 300 100 100 100
1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105
UNIT µs ms ms µs µs µs µs
NOTE
Page 3 of 5 10/03/2006 VersionA
1.25 Gigabit Ethernet-Single Mode Transceiver BL O C K D I AG R AM O F T R AN S C E I V E R Electrical Sub-assem bly TD+
LD D river
TD -
LD
T X Disable T X Fault (0) (1) (2)
M O D_ DEF
RD+
Post-A m p
RD-
O ptical Sub -assembly
D uplex LC Receptacle
PreAm p
PI N O U T D I AG R AM O F T R AN S C E I V E R 20
VEET
1
VEET
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
VEET
4
MOD-DEF2
16
VCCT
5
MOD-DEF1
15
VCCR
6
MOD-DEF0
14
VEER
7
Rate Select
13
RD+
8
LOS
12
RD-
9
VEER
11
VEER
10
VEER
Top of Board
RX _L OS
PI N O U T T ABL E Pin 1
Symbol VeeT
Transmitter Ground
2
TX Fault
Transmitter Fault Indication
3
TX Disable
Transmitter Disable – Module disables on high or open
4
MOD-DEF(2)
Module Definition 2 – Two wire serial ID interface
5
MOD-DEF(1)
Module Definition 1 – Two wire serial ID interface
6
MOD-DEF(0)
Module Definition 0 – Grounded in module
7
Rate Select
Not Connected
8
LOS
Loss of Signal
9
VeeR
Receiver Ground
10
VeeR
Receiver Ground
Functional Description
11
VeeR
Receiver Ground
12
RD-
Inverse Received Data Out
13
RD+
Received Data Out
14
VeeR
Receiver Ground
15
VccR
Receiver Power
16
VccT
Transmitter Power
17
VeeT
Transmitter Ground
18
TD+
Transmitter Data In
19
TD-
Inverse Transmitter Data In
20
VeeT
Transmitter Ground
Coretek Opto Corp.
http://www.coretek.com.tw
Buttom of Board (As Viewed through Top of Board
1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105
Page 4 of 5 10/03/2006 VersionA
1.25 Gigabit Ethernet-Single Mode Transceiver R E C O MME N D E D C I R C U I T S C H E MAT I C
RES
RES
Tx Fault Tx Disable
100
LD Driver
TD+
Z o = 50 Ω
TD-
Z o = 50 Ω
VCCT VCCR
Pre Amp
Vcc
VEET
V CCT
Post Amp
L1
Vcc
C2 L2 C3
C1
RD-
Z o = 50 Ω
RD+
Z o = 50 Ω
System 100Ω
Vcc RES
RES
RES
EEPROM
RES
RX_LOS
MOD-DEF(2) MOD-DEF(1) MOD-DEF(0) Note : 4.7 KΩ < RES < 10 KΩ L1, L 2 = 1µ H C1 = 10 µF C 2, C 3 = 0.1µ F
ME C H AN I C AL D I ME N S I O N S Units in mm
All dimensions are 0.2mm unless otherwise specified.
Claim:
CORETEK Opto Corp. reserves the right to make changes in the specification described hereinafter without prior notice.
Coretek Opto Corp.
http://www.coretek.com.tw
1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105
Page 5 of 5 10/03/2006 VersionA