Preview only show first 10 pages with watermark. For full document please download

1.25 Gigabit Ethernet-single Mode Transceiver

   EMBED


Share

Transcript

1.25 Gigabit Ethernet-Single Mode Transceiver SFP, D u p l e x LC C o n n e c t o r , C W D M LD fo r Si n g l e M o d e Fi b e r , R o H S C o m p l i a n t Digital Diagnostics Functions, Power Budget 30dB F e atu r e s • • • • • • • Applications • • CWDM • • Gigabit Ethernet Links • • Fibre Channel Links at 1.06 Gbps • High Speed Backplane Interconnects • Switched Backbones • • RoHS Pb CWDM 8 wavelengths Transmitter APD Receiver Data Rate: 1.25Gbps, NRZ Single +3.3V Power Supply RoHS Compliant and Lead-free AC/AC Differential Electrical Interface Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP) Compliant with SFF-8472 Digital Diagnostic Monitoring Interface Duplex LC Connector Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps Compliance with ANSI specifications for Fibre Channel applications at 1.06 Gbps Eye Safety Designed to meet Laser Class 1 comply with EN60825-1 D e scr iption The CT-1250TSP-CB9L-D series from Coretek Opto Corp. are the high performance and cost-effective modules for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates with +3.3V power supply. The module is intended for single mode fiber, operates at a nominal wavelength of CWDM and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module is integrated digital diagnostics functions via an I2C serial interface. The module is a duplex LC connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s long reach applications. The characteristics are performed in accordance with ITU-T G.694.2 and G.695. E MC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields. E y e S af e ty The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1. Coretek Opto Corp. http://www.coretek.com.tw 1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105 Page 1 of 5 10/03/2006 VersionA 1.25 Gigabit Ethernet-Single Mode Transceiver Pr od u ct I nf or m ation Model Number Wavelength Latch Color 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm Gray Violet Blue Green Yellow Orange Red Brown CT-1250TSP-CB9L-D Operating Voltage & SD Output Distance Output Power Sensitivity 3.3V TTL AC/AC 100 km 0 ~ +5 dBm -30 dBm A B S O L U T E M A X R A T IN G S PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current SYMBOL TS VCC --IS MIN -40 0 0 SYMBOL TA VCC VID MIN. 0 3.1 300 MAX 85 6 Vcc 300 UNIT  V V mA NOTE O P E R A T IN G C O N D IT IO N S PARAMETER Case Operating Temperature Supply Voltage Data Input Voltage Swing TYP. MAX. 70 3.5 1860 UNIT  V mV NOTE E L E C T R IC A L C H A R A C T E R IS T IC S PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High Coretek Opto Corp. http://www.coretek.com.tw SYMBOL MIN MAX UNIT ICCT VIL VIH VOL VOH 0 2.0 0 2.0 200 0.8 Vcc 0.8 Vcc mA V V V V ICCR VOD VOL VOH VIL VIH 0.4 0 2.0 -0.6 Vcc  0.7 100 1.3 0.8 Vcc Vcc  0.3 Vcc + 0.5 mA V V V V V 1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105 NOTE Page 2 of 5 10/03/2006 VersionA 1.25 Gigabit Ethernet-Single Mode Transceiver T R A N S M I T T E R E L E C T R O -O P T I C A L C H A R A C T E R I S T I C S PARAMETER Optical Output Power Extinction Ratio SYMBOL Po ER Center Wavelength c Spectral Width (-20dB) Side Mode Suppression Ratio RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye MIN 0 9 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5   SMSR RIN tr tf 30 TYP. MAX 5 1470 1490 1510 1530 1550 1570 1590 1610 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 1 -120 260 260 Compliant with IEEE802.3z/D5.0 UNIT dBm dB NOTE 1 nm nm dB dB/Hz ps ps 2 2 R E C E I V E R E L E C T R O -O P T I C A L C H A R A C T E R I S T I C S PARAMETER Maximum Input Optical Power Minimum Input Optical Power Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis SYMBOL Pmax Pmin  ORL --- PA PD PD -PA MIN -8 TYP. MAX -30 1620 1260 12 1500 -42 -29 0.5 UNIT dBm dBm nm dB MHz dBm dBm dB NOTE 3 3 Notes: 1. Measured average power coupled into 9/125m single mode fiber. 2. These are 20-80% values. 3. Measured with 27-1 PRBS at BER<10-12 T IM IN G C H A R A C T E R IS T IC S PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off) Coretek Opto Corp. http://www.coretek.com.tw SYMBOL t_off t_on t_init t_fault t_reset tA,RX_LOS tD,RX_LOS MIN 10 TYP. MAX 10 1 300 100 100 100 1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105 UNIT µs ms ms µs µs µs µs NOTE Page 3 of 5 10/03/2006 VersionA 1.25 Gigabit Ethernet-Single Mode Transceiver BL O C K D I AG R AM O F T R AN S C E I V E R Electrical Sub-assem bly TD+ LD D river TD - LD T X Disable T X Fault (0) (1) (2) M O D_ DEF RD+ Post-A m p RD- O ptical Sub -assembly D uplex LC Receptacle PreAm p PI N O U T D I AG R AM O F T R AN S C E I V E R 20 VEET 1 VEET 19 TD- 2 Tx Fault 18 TD+ 3 Tx Disable 17 VEET 4 MOD-DEF2 16 VCCT 5 MOD-DEF1 15 VCCR 6 MOD-DEF0 14 VEER 7 Rate Select 13 RD+ 8 LOS 12 RD- 9 VEER 11 VEER 10 VEER Top of Board RX _L OS PI N O U T T ABL E Pin 1 Symbol VeeT Transmitter Ground 2 TX Fault Transmitter Fault Indication 3 TX Disable Transmitter Disable – Module disables on high or open 4 MOD-DEF(2) Module Definition 2 – Two wire serial ID interface 5 MOD-DEF(1) Module Definition 1 – Two wire serial ID interface 6 MOD-DEF(0) Module Definition 0 – Grounded in module 7 Rate Select Not Connected 8 LOS Loss of Signal 9 VeeR Receiver Ground 10 VeeR Receiver Ground Functional Description 11 VeeR Receiver Ground 12 RD- Inverse Received Data Out 13 RD+ Received Data Out 14 VeeR Receiver Ground 15 VccR Receiver Power 16 VccT Transmitter Power 17 VeeT Transmitter Ground 18 TD+ Transmitter Data In 19 TD- Inverse Transmitter Data In 20 VeeT Transmitter Ground Coretek Opto Corp. http://www.coretek.com.tw Buttom of Board (As Viewed through Top of Board 1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105 Page 4 of 5 10/03/2006 VersionA 1.25 Gigabit Ethernet-Single Mode Transceiver R E C O MME N D E D C I R C U I T S C H E MAT I C RES RES Tx Fault Tx Disable 100 LD Driver TD+ Z o = 50 Ω TD- Z o = 50 Ω VCCT VCCR Pre Amp Vcc VEET V CCT Post Amp L1 Vcc C2 L2 C3 C1 RD- Z o = 50 Ω RD+ Z o = 50 Ω System 100Ω Vcc RES RES RES EEPROM RES RX_LOS MOD-DEF(2) MOD-DEF(1) MOD-DEF(0) Note : 4.7 KΩ < RES < 10 KΩ L1, L 2 = 1µ H C1 = 10 µF C 2, C 3 = 0.1µ F ME C H AN I C AL D I ME N S I O N S Units in mm All dimensions are 0.2mm unless otherwise specified. Claim: CORETEK Opto Corp. reserves the right to make changes in the specification described hereinafter without prior notice. Coretek Opto Corp. http://www.coretek.com.tw 1F,10 Industry E. Rd. IV., Science-Based Industrial Park, Hsinchu, Taiwan, R.O.C. Tel:886-3-5787871 Fax:886-3-5645105 Page 5 of 5 10/03/2006 VersionA