Transcript
1.25 Gigabit Ethernet-Single Mode Transceiver SFP, Duplex LC Connector, 1310nm FP LD for Single Mode Fiber, RoHS Compliant Features
Applications •
Gigabit Ethernet Links
•
Fibre Channel Links at 1.06 Gbps
•
High Speed Backplane Interconnects
•
Switched Backbones
•
1310nm FP LD
•
Data Rate: 1.25Gbps, NRZ
•
Single +3.3V Power Supply
•
RoHS Compliant and Lead-free
•
AC/AC Differential Electrical Interface
•
Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP)
•
Compliant with SFF-8472 Digital Diagnostic Monitoring Interface ( optional )
•
Duplex LC Connector
•
Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps
•
Compliance with ANSI specifications for Fibre Channel applications at 1.06 Gbps
•
Eye Safety Designed to meet Laser Class 1 comply with EN60825-1
Description The Mioptics MIO-GLC-LX-SM-x series from Metric are high performance and cost-effective modules for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates with +3.3V power supply. The module is intended for single mode fiber, operates at a nominal wavelength of 1310nm and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module is integrated digital diagnostics functions via an I2C serial interface ( optional ). The module is a duplex LC connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s intermediate reach applications. The characteristics are performed in accordance with Telcordia Specification GR-468-CORE.
EMC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields.
Eye Safety The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1.
Sweden
Denmark
Norway
Qdoc Metric AB Sjöängsvägen 5 192 72, Sollentuna Tel: +46 86264840 www.metric.se
Metric Industrial A/S Hassellunden 14 2765, Smørum Tel: +45 70300310 www.metric.dk
Metric Industrial AS Bjørnerudveien 17 N-1266, Oslo Tel: +47 40004054 www.metricindustrial.no
1.25 Gigabit Ethernet-Single Mode Transceiver Product Information Model Number
Operating Temperature. & Monitor Function
Distance
LD Type & Wavelength
Output Power
Sensitivity
MIO-GLC-LX-SM MIO -GLC-LX-SM-D MIO -GLC-LX-SM-T MIO -GLC-LX-SM-DT
0~70℃ 0~70℃ with DOM -40~85℃ -40~85℃ with DOM
10 km
1310 nm FP
-9.5 ~ -3 dBm
≦-23 dBm
ABSOLUTE MAX RATINGS PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current
SYMBOL TS VCC --IS
MIN -40 0 0
SYMBOL VCC VID
MIN. 3.1 300
MAX 85 6 Vcc 300
UNIT ℃ V V mA
NOTE
OPERATING CONDITIONS PARAMETER Supply Voltage Data Input Voltage Swing
TYP.
MAX. 3.5 1860
UNIT V mV
NOTE
ELECTRICAL CHARACTERISTICS PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage
Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High
SYMBOL
MIN
MAX
UNIT
ICCT VIL VIH VOL VOH
0 2.0 0 2.0
200 0.8 Vcc 0.8 Vcc
mA V V V V
ICCR VOD VOL VOH VIL VIH
0.4 0 2.0 -0.6 Vcc × 0.7
100 1.3 0.8 Vcc Vcc × 0.3 Vcc + 0.5
mA V V V V V
NOTE
TRANSMITTER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Optical Output Power Extinction Ratio Center Wavelength Spectral Width (RMS) RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye
SYMBOL Po ER λc Δλ RIN tr tf
MIN -9.5 9 1275
TYP.
MAX -3
1355 3 -117 260 260 Compliant with IEEE802.3z/D5.0
UNIT dBm dB nm nm dB/Hz ps ps
Sweden
Denmark
Norway
Qdoc Metric AB Sjöängsvägen 5 192 72, Sollentuna Tel: +46 86264840 www.metric.se
Metric Industrial A/S Hassellunden 14 2765, Smørum Tel: +45 70300310 www.metric.dk
Metric Industrial AS Bjørnerudveien 17 N-1266, Oslo Tel: +47 40004054 www.metricindustrial.no
NOTE 1 2 2 3 3
1.25 Gigabit Ethernet-Single Mode Transceiver RECEIVER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Maximum Input Optical Power Minimum Input Optical Power Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency
LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis
SYMBOL Pmax Pmin λ ORL --PA PD PD -PA
MIN -3
TYP.
MAX -23 1600
1100 12
1500 -35 -22 0.5
UNIT dBm dBm nm dB MHz dBm dBm dB
NOTE 4 4
Notes: 1. Measured average power coupled into 9/125μm single mode fiber. 2. In conformance with IEEE802.3z Figure 59-3 and FC-PI Figure 18. 3. These are 20-80% values. 4. Measured with 27-1 PRBS at BER<10-12
TIMING CHARACTERISTICS PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off)
SYMBOL t_off t_on t_init t_fault t_reset tA,RX_LOS tD,RX_LOS
MIN
TYP.
MAX 10 1 300 100
10 100 100
UNIT μs ms ms μs μs μs μs
BLOCK DIAGRAM OF TRANSCEIVER Electrical Sub-assem bly TD + TD-
LD Driver
LD
TX D isable TX Fault (0) (1) (2)
M OD _D EF
O ptical Sub-assem bly
RD + RD -
D uplex LC Receptacle
PreAm p
Post-Am p
RX _LO S
Sweden
Denmark
Norway
Qdoc Metric AB Sjöängsvägen 5 192 72, Sollentuna Tel: +46 86264840 www.metric.se
Metric Industrial A/S Hassellunden 14 2765, Smørum Tel: +45 70300310 www.metric.dk
Metric Industrial AS Bjørnerudveien 17 N-1266, Oslo Tel: +47 40004054 www.metricindustrial.no
NOTE
1.25 Gigabit Ethernet-Single Mode Transceiver PIN OUT DIAGRAM OF TRANSCEIVER 20
VEET
1
VEET
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
VEET
4
MOD-DEF2
16
VCCT
5
MOD-DEF1
15
VCCR
6
MOD-DEF0
14
VEER
7
Rate Select
13
RD+
8
LOS
12
RD-
9
VEER
11
VEER
10
VEER
Buttom of Board (As Viewed through Top of Board
Top of Board
PIN OUT TABLE Pin 1
Symbol VeeT
Functional Description Transmitter Ground
2
TX Fault
Transmitter Fault Indication
3
TX Disable
Transmitter Disable – Module disables on high or open
4
MOD-DEF(2)
Module Definition 2 – Two wire serial ID interface
5
MOD-DEF(1)
Module Definition 1 – Two wire serial ID interface
6
MOD-DEF(0)
Module Definition 0 – Grounded in module
7
Rate Select
Not Connected
8
LOS
Loss of Signal
9
VeeR
Receiver Ground
10
VeeR
Receiver Ground
11
VeeR
Receiver Ground
12
RD-
Inverse Received Data Out
13
RD+
Received Data Out
14
VeeR
Receiver Ground
15
VccR
Receiver Power
16
VccT
Transmitter Power
17
VeeT
Transmitter Ground
18
TD+
Transmitter Data In
19
TD-
Inverse Transmitter Data In
20
VeeT
Transmitter Ground
Sweden
Denmark
Norway
Qdoc Metric AB Sjöängsvägen 5 192 72, Sollentuna Tel: +46 86264840 www.metric.se
Metric Industrial A/S Hassellunden 14 2765, Smørum Tel: +45 70300310 www.metric.dk
Metric Industrial AS Bjørnerudveien 17 N-1266, Oslo Tel: +47 40004054 www.metricindustrial.no
1.25 Gigabit Ethernet-Single Mode Transceiver RECOMMENDED CIRCUIT SCHEMATIC Vcc VEET
VCCT
RES
Tx Fault RES
Tx Disable
100
LD Driver
TD+
Z o = 50 Ω
TD-
Z o = 50 Ω
VCCT VCCR
Pre Amp
Post Amp
L1
Vcc
C2 L2 C3
C1
RD-
Z o = 50 Ω
RD+
Z o = 50 Ω
System 100Ω
Vcc RES
RES
RES
EEPROM
RES
RX_LOS MOD-DEF(2) MOD-DEF(1) MOD-DEF(0)
Note : 4.7 K Ω < RES < 10 K Ω L1, L 2 = 1μH C1 = 10μF C 2, C 3 = 0.1μF
MECHANICAL DIMENSIONS Units in mm
All dimensions are ±0.2mm unless otherwise specified.
Claim: Metric reserves the right to make changes in the specification described hereinafter without prior notice.
Sweden
Denmark
Norway
Qdoc Metric AB Sjöängsvägen 5 192 72, Sollentuna Tel: +46 86264840 www.metric.se
Metric Industrial A/S Hassellunden 14 2765, Smørum Tel: +45 70300310 www.metric.dk
Metric Industrial AS Bjørnerudveien 17 N-1266, Oslo Tel: +47 40004054 www.metricindustrial.no