Preview only show first 10 pages with watermark. For full document please download

1.25g Ethernet-single Mode Transceiver

   EMBED


Share

Transcript

1.25G Ethernet-Single Mode Transceiver SFP, Duplex LC Connector, CWDM LD for Single Mode Fiber, RoHS Compliant Power Budget 30dB Features Applications  CWDM  Gigabit Ethernet Links  Fibre Channel Links at 1.06 Gbps  High Speed Backplane Interconnects  Switched Backbones  CWDM 8 wavelengths Transmitter  APD Receiver  Data Rate: 1.25Gbps, NRZ  Single +3.3V Power Supply  RoHS Compliant and Lead-free  AC/AC Differential Electrical Interface  Compliant with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP)  Compliant with SFF-8472 Digital Diagnostic Monitoring Interface ( optional )  Duplex LC Connector  Compliance with specifications for IEEE-802.3z Gigabit Ethernet at 1.25 Gbps  Compliance with ANSI specifications for Fibre Channel applications at 1.06 Gbps  Eye Safety Designed to meet Laser Class 1 comply with EN60825-1 Description The AB-GLC-Cxx-EZX-x series from BCC Solutions Oy are the high performance and cost-effective modules for serial optical data communication applications specified for single mode of 1.25 Gb/s. It operates with +3.3V power supply. The module is intended for single mode fiber, operates at a nominal wavelength of CWDM and complies with Multi-Source Agreement (MSA) Small Form Factor Pluggable (SFP). Each module is integrated digital diagnostics functions via an I2C serial interface ( optional ). The module is a duplex LC connector transceiver designed for use in Gigabit Ethernet applications and to provide IEEE-802.3z compliant link for 1.25Gb/s long reach applications. The characteristics are performed in accordance with ITU-T G.694.2 and G.695. EMC Most equipment utilizing high-speed transceivers will be required to meet the following requirements: 1) FCC in the United States 2) CENELEC EN55022 (CISPR 22) in Europe To assist the customer in managing the overall equipment EMC performance, the transceivers have been designed to satisfy FCC class B limits and provide good immunity to radio-frequency electromagnetic fields. Eye Safety The transceivers have been designed to meet Class 1 eye safety and comply with EN 60825-1. Page 1 of 6 BCC Solutions Oy Puh (09) 222 5001 Email:[email protected] www.bccsolutions.fi 1.25G Ethernet-Single Mode Transceiver Product Information Model Number AB-GLC-C47-EZX AB-GLC-C49-EZX AB-GLC-C51-EZX AB-GLC-C53-EZX AB-GLC-C55-EZX AB-GLC-C57-EZX AB-GLC-C59-EZX AB-GLC-C61-EZX AB-GLC-C47-EZX-D AB-GLC-C49-EZX-D AB-GLC-C51-EZX-D AB-GLC-C53-EZX-D AB-GLC-C55-EZX-D AB-GLC-C57-EZX-D AB-GLC-C59-EZX-D AB-GLC-C61-EZX-D AB-GLC-C47-EZX-T AB-GLC-C49-EZX-T AB-GLC-C51-EZX-T AB-GLC-C53-EZX-T AB-GLC-C55-EZX-T AB-GLC-C57-EZX-T AB-GLC-C59-EZX-T AB-GLC-C61-EZX-T AB-GLC-C47-EZX-DT AB-GLC-C49-EZX-DT AB-GLC-C51-EZX-DT AB-GLC-C53-EZX-DT AB-GLC-C55-EZX-DT AB-GLC-C57-EZX-DT AB-GLC-C59-EZX-DT AB-GLC-C61-EZX-DT Wavelength Latch Color 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm 1470 nm 1490 nm 1510 nm 1530 nm 1550 nm 1570 nm 1590 nm 1610 nm Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Gray Violet Blue Green Yellow Orange Red Brown Operating Temperature. & Monitor Function Distance Output Power Sensitivity 0~70℃ 120 km 0 ~ +5 dBm ≦-30 dBm 0~70℃ with DOM 120 km 0 ~ +5 dBm ≦-30 dBm -40~85℃ 120 km 0 ~ +5 dBm ≦-30 dBm -40~85℃ with DOM 120 km 0 ~ +5 dBm ≦-30 dBm UNIT ℃ V V mA NOTE ABSOLUTE MAX RATINGS PARAMETER Storage Temperature Supply Voltage Data Input Voltage Supply Current SYMBOL TS VCC --IS MIN -40 0 0 SYMBOL VCC VID MIN. 3.1 300 MAX 85 6 Vcc 300 OPERATING CONDITIONS PARAMETER Supply Voltage Data Input Voltage Swing TYP. MAX. 3.5 1860 UNIT V mV NOTE Page 2 of 6 BCC Solutions Oy Puh (09) 222 5001 Email:[email protected] www.bccsolutions.fi 1.25G Ethernet-Single Mode Transceiver ELECTRICAL CHARACTERISTICS PARAMETER Transmitter Transmitter Supply Current Tx_ Disable Input Voltage - Low Tx_ Disable Input Voltage - High Tx_ Fault Output Voltage - Low Tx_ Fault Output Voltage - High Receiver Receiver Supply Current Receiver Data Output Differential Voltage Rx_LOS Output Voltage - Low Rx_LOS Output Voltage - High MOD_DEF (1) , MOD_DEF (2) - Low MOD_DEF (1) , MOD_DEF (2) - High SYMBOL MIN MAX UNIT ICCT VIL VIH VOL VOH 0 2.0 0 2.0 200 0.8 Vcc 0.8 Vcc mA V V V V ICCR VOD VOL VOH VIL VIH 0.4 0 2.0 -0.6 Vcc × 0.7 100 1.3 0.8 Vcc Vcc × 0.3 Vcc + 0.5 mA V V V V V NOTE TRANSMITTER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Optical Output Power Extinction Ratio SYMBOL Po ER λc Center Wavelength Δλ SMSR RIN tr tf Spectral Width (-20dB) Side Mode Suppression Ratio RIN Optical Rise time (20%-80% ) Optical Fall time (20%-80% ) Output Eye MIN 0 9 1464.5 1484.5 1504.5 1524.5 1544.5 1564.5 1584.5 1604.5 TYP. 1470 1490 1510 1530 1550 1570 1590 1610 MAX 5 1477.5 1497.5 1517.5 1537.5 1557.5 1577.5 1597.5 1617.5 1 30 -120 260 260 Compliant with IEEE802.3z/D5.0 UNIT dBm dB NOTE 1 nm nm dB dB/Hz ps ps 2 2 RECEIVER ELECTRO-OPTICAL CHARACTERISTICS PARAMETER Maximum Input Optical Power Minimum Input Optical Power Operating Wavelength Optical Return Loss Receiver Electrical 3dB Upper Cutoff Frequency LOS of Signal - Asserted LOS of Signal - Deasserted Loss of Signal -Hysterisis SYMBOL Pmax Pmin λ ORL --PA PD PD -PA MIN -8 TYP. MAX 1260 12 -30 1620 1500 -42 -29 0.5 UNIT dBm dBm nm dB MHz dBm dBm dB NOTE 3 3 Notes: 1. Measured average power coupled into 9/125μm single mode fiber. 2. These are 20-80% values. 3. Measured with 27-1 PRBS at BER<10-12 Page 3 of 6 BCC Solutions Oy Puh (09) 222 5001 Email:[email protected] www.bccsolutions.fi 1.25G Ethernet-Single Mode Transceiver TIMING CHARACTERISTICS PARAMETER TX_DISABLE Assert Time TX_DISABLE Negate Time Time to initialize, include reset of TX_FAULT TX_FAULT from fault to assertion TX_DISABLE time to start reset Receiver Loss of Signal Assert Time (off to on) Receiver Loss of Signal Assert Time (on to off) SYMBOL t_off t_on t_init t_fault t_reset tA,RX_LOS tD,RX_LOS BLOCK DIAGRAM OF TRANSCEIVER MIN TYP. MAX 10 1 300 100 UNIT μs ms ms μs μs μs μs 10 100 100 NOTE PIN OUT DIAGRAM OF TRANSCEIVER Electrical Sub-assembly 20 VE ET 1 VE ET 19 TD- 2 Tx Fault 18 TD+ 3 Tx Dis able 17 VE ET 4 M OD-DEF2 16 VC CT 5 M OD-DEF1 15 VC CR 6 M OD-DEF0 14 VE ER 7 Rate Select 13 RD+ 8 LOS 12 RD- 9 VE ER 11 VE ER 10 VE ER TD+ LD Driver TD- LD TX Disable TX Fault (0) (1) MOD_DEF Optical Sub-assembly Duplex LC Receptacle (2) RD+ Post-Amp RD- PreAmp Top of Board RX_LOS Buttom of Board (As Viewed through Top of Board PIN OUT TABLE Pin 1 Symbol VeeT Transmitter Ground Functional Description 2 TX Fault Transmitter Fault Indication 3 TX Disable Transmitter Disable – Module disables on high or open 4 MOD-DEF(2) Module Definition 2 – Two wire serial ID interface 5 MOD-DEF(1) Module Definition 1 – Two wire serial ID interface 6 MOD-DEF(0) Module Definition 0 – Grounded in module 7 Rate Select Not Connected 8 LOS Loss of Signal 9 VeeR Receiver Ground 10 VeeR Receiver Ground 11 VeeR Receiver Ground 12 RD- Inverse Received Data Out 13 RD+ Received Data Out 14 VeeR Receiver Ground 15 VccR Receiver Power 16 VccT Transmitter Power 17 VeeT Transmitter Ground 18 TD+ Transmitter Data In 19 TD- Inverse Transmitter Data In 20 VeeT Transmitter Ground Page 4 of 6 BCC Solutions Oy Puh (09) 222 5001 Email:[email protected] www.bccsolutions.fi 1.25G Ethernet-Single Mode Transceiver RECOMMENDED CIRCUIT SCHEMATIC Vcc VEET VCCT RES Tx Fault RES Tx Disable 100 LD Driver TD+ Z o  50  TD- Z o  50  Vcc L1 VCCT C2 L2 VCCR Pre Amp Post Amp C3 C1 RD- Z o  50  RD+ Z o  50  System 100 Vcc RES RES RES EEPROM RES RX_LOS MOD-DEF(2) MOD-DEF(1) MOD-DEF(0) Note : 4.7 K   RES  10 K  L1, L 2  1H C1  10F C 2, C 3  0.1F Page 5 of 6 BCC Solutions Oy Puh (09) 222 5001 Email:[email protected] www.bccsolutions.fi 1.25G Ethernet-Single Mode Transceiver MECHANICAL DIMENSIONS Units in mm All dimensions are ±0.2mm unless otherwise specified. Claim: BCC Solutions Oy reserves the right to make changes in the specification described hereinafter without prior notice. Page 6 of 6 BCC Solutions Oy Puh (09) 222 5001 Email:[email protected] www.bccsolutions.fi