Transcript
Intel® RAID Modules RMSP3AD160F, RMSP3CD080, and RMSP3HDO80E Hardware User Guide A document providing an overview of product features, specification data, and hardware installation instructions
Rev 1.0 July 2017 Intel® Server Products and Solutions
ii
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E Hardware User Guide
Document Revision History
iii
Date
Revision
Jul 2017
1.0
Changes Initial release.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E Hardware User Guide
Disclaimers Intel technologies’ features and benefits depend on system configuration and may require enabled hardware, software, or service activation. Performance varies depending on system configuration. No computer system can be absolutely secure. Check with your system manufacturer or retailer or learn more at Intel.com. No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. Intel disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose, and non-infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade. The products and services described may contain defects or errors known as errata which may cause deviations from published specifications. Current characterized errata are available on request. You may not use or facilitate the use of this document in connection with any infringement or other legal analysis concerning Intel products described herein. You agree to grant Intel a non-exclusive, royalty-free license to any patent claim thereafter drafted which includes subject matter disclosed herein. Intel, the Intel logo, are trademarks of Intel Corporation in the U.S. and/or other countries. *Other names and brands may be claimed as the property of others. © Intel Corporation 2017. All rights reserved.
iv
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E Hardware User Guide
Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information at https://www.intel.com/content/dam/support/us/en/documents/motherboards/server/sb/g23122004_safetyregulatory.pdf
Wichtige Sicherheitshinweise Lesen Sie zunächst sämtliche Warnund Sicherheitshinweise in diesem Dokument, bevor Sie eine der Anweisungen ausführen. Beachten Sie hierzu auch die Sicherheitshinweise zu Intel-Serverplatinen und Servergehäusen auf der https://www.intel.com/content/dam/support/us/en/documents/motherboards/server/sb/g23122004_safetyregulatory.pdf
Consignes de sécurité Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le site https://www.intel.com/content/dam/support/us/en/documents/motherboards/server/sb/g23122004_safetyregulatory.pdf
Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y precaución de este documento antes de realizar cualquiera de las instrucciones. Vea Intel Server Boards and Server Chassis Safety Information en https://www.intel.com/content/dam/support/us/en/documents/motherboards/server/sb/g23122004_safetyregulatory.pdf
重要安全指导 在执行任何指令之前,请阅读本文档中的所有注意事项及安全声明。和/或 https://www.intel.com/content/dam/support/us/en/documents/motherboards/server/sb/g23122004_safetyregulatory.pdf 上的 Intel® Server Boards and Server Chassis Safety Information(《Intel 服务器主板与服务器机箱安全信 息》)。
v
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E Hardware User Guide
Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products/components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold. System power on/off: The power button DOES NOT turn off the system AC power. To remove all power from the system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the chassis, add, or remove any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Installing or removing jumpers: A jumper is a small plastic-encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle-nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Electrostatic discharge (ESD) and ESD protection: ESD can damage disk drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an anti-static wrist strap attached to chassis ground, any unpainted metal surface on your server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static-free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface.
vi
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
1.
Preface
1.1
About This Document
This document provides an overview of product features, specification data, and hardware installation instructions for the Intel® Redundant Array of Inexpensive Disks (RAID) Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E.
1.2
Document Organization
This document includes the following: Chapter 1 – Product Overview – Provides a product overview of the features set and support specifications. Chapter 2 – General Feature Overview – Provides a brief description for the features that are common for the products covered by this guide. Chapter 3 – Detailed Characteristics – Provides details on the characteristics for each of the products covered by this guide. Chapter 4 – Connectivity and Drive Support – Provides description of what drives are supported by the products covered by this guide and the way to connect them. Chapter 5 – Hardware Installation - Provides support for the installation of the product on the Intel systems where they are supported. Chapter 6 – Safety and Regulatory Chapter 7 – Intel® RAID Maintenance Free Backup Unit AXXRMFBU7 – Provides details of the Intel® RAID Maintenance-Free Backup Unit AXXRMFBU7 accessory option. Appendix A. Glossary of Terms Reference Documents and Online Articles The following documents are available for download and will be useful to setting up and using the Intel RAID controller. Document Title Intel® RAID Software User Guide for full featured and entry level RAID controllers
Description A document that provides information on RAID Card Setup and usage of supported RAID utility software. http://www.intel.com/content/www/us/en/support/serverproducts/raid-products/000024126.html
What to Do when Unable to Enter BIOS or Intel® RAID BIOS Console During Boot for Intel® Server Boards
Article ID: 000059999. If the Intel or OEM logo screen displays during POST, the BIOS entry or Intel® RAID BIOS console command prompts are not visible. To gain access to these prompts, disable the logo screen.
12 Gbps SAS or 6G SATA Data Transfer Controller Support for Intel® RAID Controllers
Article ID# 000008025. A document that provides information on how and where the controller supports 12-Gbps SAS (6G SATA) data transfers.
1
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
1.3
Product Support Collaterals
In addition to this user guide, Intel provides documentation, device driver updates, and utilities that may be necessary and/or useful for operation and support of this product. Additional product support collaterals can be downloaded from the following Intel websites: For product documentation, go to the following Intel website: http://www.intel.com/support/ For product device drives and other software utilities, go to the following Intel website: https://downloadcenter.intel.com
2
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Table of Contents 1. Preface ........................................................................................................................................................................... 1 1.1
About This Document ..................................................................................................................................................... 1
1.2
Document Organization ................................................................................................................................................. 1
1.3
Product Support Collaterals ......................................................................................................................................... 2
1. Product Overview ........................................................................................................................................................ 8 2. Intel® Tri-Mode RAID Module General Features ................................................................................................... 9 2.1
Overview ............................................................................................................................................................................... 9
2.2
Benefits of the SAS Interface ....................................................................................................................................... 9
2.3
Benefits of the NVM Express (NVMe) Interface .................................................................................................... 9
2.4
Intel® Tri-Mode RAID Module Features .................................................................................................................... 9
2.4.1
SAS Features ....................................................................................................................................................................... 9
2.4.2
SATA III Features ............................................................................................................................................................. 10
2.4.3
NVMe Interface Features............................................................................................................................................. 10
2.4.4
Usability Features........................................................................................................................................................... 10
2.4.5
Flexibility Features ......................................................................................................................................................... 10
2.4.6
Drive Roaming ................................................................................................................................................................. 10
2.4.7
Drive Migration ................................................................................................................................................................ 11
2.4.8
Safety Characteristics................................................................................................................................................... 11
2.5
Intel® Tri-Mode RAID Controller Feature Set ...................................................................................................... 12
2.6
Data Protection Features ............................................................................................................................................ 13
2.7
Fault Tolerance Features............................................................................................................................................. 14
2.8
Array Performance Features ...................................................................................................................................... 14
2.9
Drive Support Limits ..................................................................................................................................................... 15
2.10
Over temperature protection .................................................................................................................................... 15
2.11
UART Interface ............................................................................................................................................................... 15
2.12
Optional Intel® RAID Maintenance Free Backup Unit (RMFBU) ................................................................... 16
3. Intel® Tri-Mode RAID Module Detailed Characteristics ................................................................................... 17 3.1
Intel® RAID Module RMSP3AD160F Description .............................................................................................. 17
3.1.1
Intel® RAID Module RMSP3AD160F Dimensions .............................................................................................. 19
3.1.2
Intel® RAID Module RMSP3AD160F Electrical, Thermal and Atmospheric Requirements ............. 20
3.1.3
Intel® RAID module RMSP3AD160F Power Consumption ............................................................................ 20
3.2
Intel® RAID Controller RMSP3CD080F .................................................................................................................. 21
3.2.1
Intel® RAID Module RMSP3CD160F Dimensions .............................................................................................. 23
3.2.2
Intel® RAID module RMSP3CD080F Power Consumption ............................................................................ 24
3.3
Intel® RAID module RMSP3HD080E ....................................................................................................................... 25
3.3.1
Intel® RAID Module RMSP3HD080E Dimensions.............................................................................................. 27
3.3.2
Intel® RAID Module RMSP3HD080E Electrical, Thermal and Atmospheric Requirements ............. 28
3.3.3
Intel® RAID Module RMSP3HD080E Power Consumption............................................................................ 28
4. Connectivity and Drive Support ............................................................................................................................ 29 4.1 3
Connectivity and Drive Support ............................................................................................................................... 29
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide 4.2
Connector Pinout ........................................................................................................................................................... 29
4.3
SAS/SATA Drive Support ............................................................................................................................................ 30
4.4
Intel® 12 Gb/s SAS 3.0 Expander Support ........................................................................................................... 31
4.4.1 4.5
SAS Expander Configuration for the Intel® RMSP3AD160F RAID Module............................................. 31 NVMe Drive Support ..................................................................................................................................................... 33
5. Hardware Installation .............................................................................................................................................. 35 5.1
Intel® RAID Module Installation ................................................................................................................................ 35
5.1.1
Requirements................................................................................................................................................................... 35
5.1.2
Packing List ....................................................................................................................................................................... 35
5.1.3
Installation Instructions ............................................................................................................................................... 35
6. Safety and Regulatory (Class A) ............................................................................................................................ 37 6.1
Product Safety Compliance ....................................................................................................................................... 37
6.2
Product EMC Compliance – Class A Compliance .............................................................................................. 37
6.3
Product Environmental Compliance ...................................................................................................................... 37
7. Intel® RAID Maintenance Free Backup Unit AXXRMFBU7 (RMFBU) .............................................................. 38 7.1
Intel® RAID Maintenance Free Backup Unit AXXRMFBU7 ............................................................................. 38
7.2
FBU345 Specifications and Layout......................................................................................................................... 39
7.2.1
Extender Cable ................................................................................................................................................................ 41
7.3
Intel® RAID Maintenance Free Backup Unit Installation................................................................................. 41
7.4
Monitoring the Intel® RAID Maintenance Free Backup Unit ......................................................................... 42
7.4.1 Appendix A.
Monitoring the RMFBU with the Human Interface Infrastructure. ............................................................. 43 Glossary ................................................................................................................................................. 46
4
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
List of Figures Figure 1. Intel® RMSP3AD160F RAID module layout........................................................................................................... 17 Figure 2. Intel® RMSP3AD160F RAID Module LED description ..................................................................................... 18 Figure 3. Intel® RMSP3AD160F RAID module dimensions ............................................................................................. 19 Figure 4. Intel® RMSP3CD160F RAID module layout ......................................................................................................... 21 Figure 5. Intel® RMSP3CD160F RAID module LED description ................................................................................... 22 Figure 6. Intel® RMSP3CD160F RAID module dimensions .............................................................................................. 23 Figure 7. Intel® RMSP3HD080E RAID module layout ......................................................................................................... 25 Figure 8. Intel® RMSP3HD080E RAID Module LED description ................................................................................... 26 Figure 9. Intel RMSP3HD080E RAID module dimensions .............................................................................................. 27 Figure 10. Intel® RMSP3AD160F RAID Module SFF-8643 connector ........................................................................ 29 Figure 11. Supported Intel® SAS expander options ................................................................................................................... 31 Figure 12. RAID module RMS3PAD160 SAS port domain identification ........................................................................... 31 Figure 13. SAS ports for the RES3FV288 ........................................................................................................................................ 32 Figure 14. SAS ports for the RES3TV360........................................................................................................................................ 32 Figure 11. Connecting the AXXCBL700HDCV to the backplane ........................................................................................... 33 Figure 12. Connecting the AXXCBL700HDCV cable to the RAID module ......................................................................... 34 Figure 13. Barrel standoff placement and installation .............................................................................................................. 35 Figure 14. Intel® RAID module placement and installation ..................................................................................................... 36 Figure 15. FBU345 layout ...................................................................................................................................................................... 40 Figure 16. Extender cable pinout ....................................................................................................................................................... 41 Figure 17. AXXRMFBU7 mounting assembly ................................................................................................................................ 41 Figure 18. RMFBU assembly installation (example).................................................................................................................... 42 Figure 19. Connecting the FBU345 to the RAID module using the extender cable ...................................................... 42 Figure 20. HII Dashboard view screen .............................................................................................................................................. 43 Figure 21. HII Hardware Components screen ............................................................................................................................... 44 Figure 22. HII Battery Management screen .................................................................................................................................... 44
List of Tables Table 1. Intel® Tri-Mode RAID module comparative feature set ........................................................................................... 12 Table 2. Data protection features....................................................................................................................................................... 13 Table 3. Fault-tolerant features .......................................................................................................................................................... 14 Table 4. Array performance features ................................................................................................................................................ 14 Table 5. SAS/SATA drive support limits .......................................................................................................................................... 15 Table 6. UART connector pinout ........................................................................................................................................................ 16 Table 7. SFF-8643 connector pinout................................................................................................................................................ 30 Table 8. FBU345 specifications ........................................................................................................................................................... 39
5
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
6
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
7
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
1.
Product Overview
The Intel® RAID Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E are part of the new family of Intel® RAID controllers. This new family of Tri-Mode RAID controllers allow for creating RAID configurations with SAS drives, SATA drives, or NVMe drives. The Intel® RAID Modules RMSP3AD160F, RMSP3CD080F, and RMSP3HD080E are high-performance, intelligent controllers with RAID control capability. The Tri-Mode RAID Controllers provide reliability, highperformance, and fault-tolerant drive subsystem management. The Tri-Mode RAID modules are based on the LSI SAS IC technology and proven MegaRAID technology. Intel offers a family of Tri-Mode RAID modules that address the needs for internal connectivity solutions as well as low and high port count: • • •
RMSP3AD160F – Full-featured Tri-Mode RAID controller with 16 internal ports RMSP3CD080F – Full-featured Tri-Mode RAID controller with eight (8) internal ports RMSP3HD080E – Entry level Tri-Mode RAID controller with eight (8) internal ports
NOTE: The Intel Tri-Mode controllers are designed to work on systems configured for optimized UEFI boot mode. There is no built-in configuration utility for these controllers when the system is configured for legacy boot mode. Some controllers like RMSP3HD080E will not work when the system they are installed on is configured for legacy boot mode.
8
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2.
Intel® Tri-Mode RAID Module General Features
2.1
Overview
The Intel® Tri-Mode controllers include a SAS interface and an NVMe interface. Both share the same connectors by multiplexing the data and sideband signals. As compared with the previous generation of Intel RAID controllers, the new Tri-Mode family offers increased performance by reducing latency, increasing IOPS, increasing queue depth and increasing cache memory. They also offer NVMe drive support to allow doing hardware RAID using these new technology drives.
2.2
Benefits of the SAS Interface
SAS is a serial, point-to-point, enterprise-level device interface that leverages the proven SCSI protocol set. SAS is a convergence of the advantages of SATA, SCSI, and Fiber Channel and the mainstay of the enterprise and high-end workstation storage markets. The SAS interface uses the SCSI command set to ensure reliable data transfers while providing the connectivity and flexibility of point-to-point serial data transfers. The serial transmission of SCSI commands eliminates clock-skew challenges. The SAS interface provides improved performance, simplified cabling, smaller connectors, and lower pin count and power requirements when compared to the original parallel SCSI. SAS controllers leverage a common electrical and physical connection interface that is compatible with Serial ATA (SATA) technology. The SAS protocols and the SATA III protocols use a common thin, 7-wire connector. The SAS/SATA III connector and cable are easier to manipulate, allow connections to smaller devices, and do not inhibit airflow. The point-to-point SATA III architecture eliminates inherent difficulties created by the legacy ATA master-slave architecture while maintaining compatibility with existing ATA firmware.
2.3
Benefits of the NVM Express (NVMe) Interface
NVMe (non-volatile memory express) is a storage protocol created to accelerate the transfer of data with solid-state drives (SSDs) by utilizing multiple PCIe connections. Benefits are increased bandwidth (up to 8Gb/s per lane), lower latency, increased efficiency, lower CPU utilization with multiple long command queues and lower power.
2.4
Intel® Tri-Mode RAID Module Features
Next is an explanation of the features of the Intel® Tri-Mode RAID Modules.
2.4.1
SAS Features
Characteristics of the SAS interface.
•
• • • •
9
Supports the following: o 12 Gb/s, 6Gb/s, and 3Gb/s SAS data transfers per PHY. o SMP communicating topology management information. o SSP enabling communication with other SAS devices. o STP enabling communication with SATA devices through an attached expander. Provides a serial, point-to-point, enterprise-level storage interface. Simplifies cabling between devices. Provides a scalable interface that supports up to 240 devices through the use of expanders. Supports x2 through x8 wide ports that consist of two (2), four (4), or eight(8) PHYs within a single port.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2.4.2
SATA III Features
The SAS interface is compatible with SATA and it has the following characteristics. •
• • • •
2.4.3
Supports the following: o SATA III data transfers up to 6Gb/s. o STP data transfers up to 6Gb/s. Provides a serial, point-to-point storage interface. Simplifies cabling between devices. Eliminates the master-slave construction used in parallel ATA. Permits addressing of multiple SATA targets through an expander.
NVMe Interface Features
The new NVMe interface has the following characteristics. •
• • • •
2.4.4
Supports the following: o Data transfers of 8Gb/s per lane (32 Gb/s when 4 PCIe lanes are being used). o PCI Bus Power Management Interface Specification, Revision 1.2. o Active State Power Management, states, by placing links in a power-saving mode during times of no link activity. Supports PCIe Hot Plug. Supports error handling. Provides high bandwidth per pin with low overhead and low latency. Supports lane reversal and polarity inversion.
Usability Features
The Tri-Mode RAID modules have the next usability characteristics. • • •
Drives spin-up sequencing control. Provides one (1) LED signal to indicate link activity for all PHYs through the motherboard for the drive activity LED on the chassis. Supports the internal SAS sideband signal SFF-8485 (SGPIO) interface.
Note: LED signals indicate an error condition or drive activity. RAID controllers support several blink patterns for these LEDs, depending on the user configuration and storage enclosure. For information about the LED blink patterns, contact the storage enclosure manufacturer.
2.4.5
Flexibility Features
The Tri-Mode RAID modules have the next flexibility characteristics. • • • • • •
2.4.6
Flash ROM interface, a non-volatile static RAM (NVSRAM) interface. Flexible programming interface to tune I/O performance. Permit mixed connections to SAS targets or SATA III targets. Leverage-compatible connectors for SAS connections and SATA III connections. Permit grouping of up to eight (8) PHYs into a single SAS-wide port. Permit programming of the World Wide Name.
Drive Roaming
Drive roaming occurs when once a VD is already set up, some or all of the drives that are part of this VD are manually changed to different ports on the same controller. When this happens, the controller detects the RAID configuration from the configuration data on the drives. 10
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Configuration data is saved in both the NVRAM on the RAID controller and on the drives attached to the controller. This feature maintains the integrity of the data on each drive, even if the drives have changed their physical device ID. More information on how to use the drive roaming feature can be found on the Intel® RAID Software User Guide for full featured and entry level RAID controllers.
2.4.7
Drive Migration
The Intel® Tri-Mode RAID Module allow to move one VD from one controller to another, this is called Drive Migration. In other words, Drive Migration is the transfer of a set of drives in an existing configuration from one controller to another. In order to achieve this, there are some conditions: 1) The drives must remain on the same channel. 2) The drives must be reinstalled in the same order as in the original configuration. 3) The controller to which the drives are migrated cannot have an existing configuration. Note: When drives are migrated, move only the drives that make up the virtual drive (not all of the drives in a drive group), so that an NVRAM mismatch error does not occur (provided a configuration is on the destination controller). The NVRAM mismatch error appears only when all of the drives are moved to the other controller. Note: Drive roaming and drive migration cannot be supported at the same time. More information on how to use the drive migration feature can be found on the Intel® RAID Software User Guide for full featured and entry level RAID controllers.
2.4.8
Safety Characteristics
All the Intel® Tri-Mode RAID Modules meet or exceed the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier name or trademark, type, and UL flammability rating.
11
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2.5
Intel® Tri-Mode RAID Controller Feature Set
The following table describes the feature set of the Intel Tri-Mode RAID modules. Table 1. Intel® Tri-Mode RAID module comparative feature set Feature I/O Processor RAID Levels JBOD Mode or Pass through Mode (SAS/SATA)
RMSP3AD160F Avago* SAS3516 PCIe* RAID On-Chip (ROC)
RMSP3CD080F Avago* SAS3508 PCIe* RAID On-Chip (ROC)
RMSP3HD080E Avago* SAS3508 PCIe* RAID On-Chip (ROC)
0,1,5,6,10, 50, 60
0,1,5,6,10, 50, 60
0,1,5,10
Yes
Yes
Yes
Cache Memory
4 GB DDR4 at 2133 MHz
4 GB DDR4 at 2133 MHz
N/A
Form Factor
Modular Mezzanine
Modular Mezzanine
Drive Interface Connectors
Modular Mezzanine
4
2
2
PCIe* Interface
x8 PCI Express* 3.0. PCIe Performance up to 8 GT/s per lane
x8 PCI Express* 3.0. PCIe Performance up to 8 GT/s per lane
x8 PCI Express* 3.0. PCIe Performance up to 8 GT/s per lane
Data Transfer Rates
12, 6, & 3 Gbps per port SAS, 6 & 3 Gbps per port SATA and 8 Gbps per lane NVMe
12, 6, & 3 Gbps per port SAS, 6 & 3 Gbps per port SATA and 8 Gbps per lane NVMe
12, 6, & 3 Gbps per port SAS, 6 & 3 Gbps per port SATA and 8 Gbps per lane NVMe
Operating Temperature
Maximum ambient: 55°C
Maximum ambient: 55°C
Maximum ambient: 55°C
Operating System
Microsoft Window*, Linux* (SuSE*, Red Hat*) Solaris* FreeBSD*
Microsoft Window*, Linux* (SuSE*, Red Hat*) Solaris* FreeBSD*
Microsoft Window*, Linux* (SuSE*, Red Hat*) Solaris* FreeBSD*
Drive Types
SAS, SATA, NVMe
SAS, SATA, NVMe
SAS, SATA, NVMe
Maximum NVMe Drives supported **
4
2
2
Maximum SAS/SATA Drives supported ***
64
64
63
64 (SAS/SATA/NVMe)
64 (SAS/SATA/NVMe)
32 (SAS/SATA/NVMe)
Advanced array configuration and management utilities
Yes
Yes
Yes
Support for global hot spares and dedicated hot spares
Yes
Yes
Only global hot spares
Support for userdefined strip sizes: 8, 16, 32, 64, 128, 256, 512, or 1024 KB
Yes
Yes
No
Yes
Yes
No
Maximum Virtual Drives**
Advanced array configuration and management utilities offer these capabilities:
•
Online capacity expansion
•
Online RAID level migration
•
Drive migration
•
Drive roaming
12
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Feature
RMSP3AD160F
RMSP3CD080F
RMSP3HD080E
User-specified rebuild rate (specifying the percentage of system resources to use from 0 percent to 100 percent)
Yes
Yes
No
Nonvolatile random access memory (NVRAM) of 32 KB for storing RAID system configuration information; the MegaRAID SAS firmware is stored in flash ROM for easy upgrade.
Yes
Yes
Yes
Yes
Yes
Intel® accessory AXXRMFBU7 (Optional)
Intel® accessory AXXRMFBU7 (Optional)
No
Yes (SAS and SATA)
Yes (SAS and SATA)
No
SSD Cache Support
No
No
No
Snapshot Recovery
No
No
No
•
No reboot necessary after expansion
•
Media scan
Support for RAID Maintenance Free Backup Unit (RMFBU). Used to save RAID cache in event of unexpected power loss Self-Encrypting Drive Support (TCG enterprise)
MTBF(hours) Standard Warranty
2,866,972
3,063,725
5,030,181
3 years, AWR options
3 years, AWR options
3 years, AWR options
** This setting is firmware-dependent. *** Devices include drives and expanders. Drives on dual-ported backplanes count twice.
2.6
Data Protection Features
The next table describes the Data protection features of the Intel® Tri-Mode RAID modules. Table 2. Data protection features Feature On-line Capacity Extension
13
RMSP3AD160F Yes
RMSP3CD080F Yes
RMSP3HD080E No
Distributed Sparing
Yes
Yes
No
Background Consistency Checking
Yes
Yes
Yes
Patrol Read for Media Functionality
Yes
Yes
Yes
S.M.A.R.T Support
Yes
Yes
Yes
Enclosure Management
Yes
Yes
Yes
RAID Support Before Operating System Loaded
Yes
Yes
Yes
Write Back Cache with Optional Protection
Yes
Yes
No
Intel® RAID Management Software
Yes
Yes
Yes
Hot-Spare Support, Global and Dedicated
Yes
Yes
Only Global
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2.7
Fault Tolerance Features
The next table describes the Fault-tolerant features of the Intel® Tri-Mode RAID modules Table 3. Fault-tolerant features Specification
RMSP3AD160F
Support for SMART1
RMSP3CD080E RMSP3HD160F
Yes
Yes
Yes
Drive failure detection
Automatic
Automatic
Automatic
Drive rebuild using hot spares
Automatic
Automatic
Automatic
Parity generation and checking
Yes
Yes
Yes
The Self-Monitoring Analysis and Reporting Technology (SMART) detects up to 70 percent of all predictable drive failures. In addition, SMART monitors the internal performance of all motors, heads, and drive electronics.
1
2.8
Array Performance Features
The next table describes the Array performance features of the Intel® Tri-Mode RAID modules Table 4. Array performance features Specification
RMSP3AD160F
RMSP3CD080E
RMSP3HD160F
PCI Express host data transfer
8GT/s per lane
8GT/s per lane
8GT/s per lane
Drive data transfer rate
Up to 12Gb/s per PHY (SAS)
Up to 12Gb/s per PHY (SAS)
Up to 12Gb/s per PHY (SAS)
Up to 6 per port (SATA)
Up to 6 per port (SATA)
Up to 6 per port (SATA)
Up to 8Gb/s per lane (NVMe)
Up to 8Gb/s per lane (NVMe)
Up to 8Gb/s per lane (NVMe)
Maximum scatter/gather I/O
60 elements
60 elements
60 elements
Maximum size of I/O requests
6.4 MB in 64-KB strips
6.4 MB in 64-KB strips
6.4 MB in 64-KB strips
Maximum queue tags per drive
As many as the drive can accept
As many as the drive can accept
As many as the drive can accept
Strip sizes
8 KB, 16 KB, 32 KB, 64 KB, 128 8 KB, 16 KB, 32 KB, 64 KB, 128 64K KB, 256 KB, 512 KB, or 1 MB KB, 256 KB, 512 KB, or 1 MB
Queue Depth (SAS/SATA)
4096
4096
1517
14
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2.9
Drive Support Limits
The next table describes the SAS/SATA drive support limits of the Intel® Tri-Mode RAID modules Table 5. SAS/SATA drive support limits RSP3AD160F
RSP3CD080F
RSP3HD080E
Maximum virtual drives per controller
64
64
32
Maximum drive groups per controller
64
64
32
Maximum virtual drives per drive group
16
16
16
Maximum drives per drive group
32
32
32
Maximum physical devices per controller
64
64
63
Maximum hot spares per controller
64
64
63
Maximum spans per virtual drive
8
8
8
3**
3**
2**
Specification
Maximum enclosures ** This setting is firmware-dependent.
2.10 Over temperature protection The Intel® Tri-Mode RAID modules are designed to operate at a maximum 55 degrees Celsius with a minimum of 200 LFM air flow, this ensures the internal ROC IC will operate at less than 105 Celsius. If for any reason there’s an overheating, the internal ROC over temperature protection circuitry will operate like this: - If the ROC reaches 110 degrees Celsius, the over temperature LED is turned on, I/O is throttled and the event “MR_EVT_CTRL_TEMP_ABOVE_OPTIMAL_RANGE” is be registered in the controller’s log. - if the ROC temperature goes down below 105 degrees Celsius (mostly due to I/O throttling), the over temperature LED is turned off, the event “MR_EVT_CTRL_TEMP_WITHIN_OPTIMAL_RANGE” is registered in the controller’s log and I/O throttling is turned off. - If the ROC reaches 116 degrees Celsius, the over temperature LED continues to lit, I/O continues to throttle, the event “MR_EVT_CTRL_TEMP_CRITICAL ” is registered in the controller’s log, then after 10 seconds of operation the cache is flushed, pending I/Os are completed and the ROC enters into the “Montask” state, in which state all I/Os stop except through the UART debugging interface. Additionally the Intel® Tri-Mode RAID modules have an on-board temperature sensor which can be monitored by the system’s BMC. When the system’s fan speed control is properly configured, the BMC speeds up the fans in order to cool down a RAID module that reaches the configured upper temperature limit. More information on how to configure the system’s fan speed control can be found in this White Paper:
2.11 UART Interface The Intel® Tri-Mode RAID modules include a UART interface for special debugging purposes. The UART connector debug port requires a special cable and Intel support to gather detailed ROC/IOC status. The UART connector uses the layout shown in the following table:
15
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Table 6. UART connector pinout Pin
Function
1
UART_TX
2
GND
3
UART_RX
4
1.8 V
The default communication parameters are 115,200 b/s, 8-bit characters, no parity bit, one stop bit, and no XON/XOFF flow control.
2.12 Optional Intel® RAID Maintenance Free Backup Unit (RMFBU) To protect the integrity of cached data on the Intel® RAID Module during a power loss event, the Intel® Tri-Mode Modules RMSP3AD160F and RMSP3CD080F provide support for the Intel® Maintenance Free Backup Unit (RMFBU – Intel Accessory Kit AXXRMFBU7). During a power loss event, this optional accessory provides backup power to the RAID Module, allowing the controller to offload the data stored in the on-board cache to its non-volatile NAND flash. Benefits of the RMFBU option as compared with traditional batteries: • • • • •
Capacitor technology has a longer usable life span than batteries and reduces maintenance and replacement costs. Capacitors do not have the chemical volatility of batteries, which carry a risk of exothermic events. RMFBU options do not require the comprehensive certifications required of batteries in order to import and export them. The RMFBU can constantly maintain the RAID volume in write back mode even when doing learn cycles. The recharge rate of the super-capacitor is minutes as compared to hours for a battery.
See Chapter 7 for additional RMFBU information.
16
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.
Intel® Tri-Mode RAID Module Detailed Characteristics
3.1
Intel® RAID Module RMSP3AD160F Description
The Intel® RAID Module RMSP3AD160F is a full-featured Tri-Mode RAID controller with 16 internal ports based on the Avago® SAS3516 RAID-On-Chip (ROC). It supports RAID levels 0, 1, 5,6,10, 50, 60 and includes 4 GB of 72-bit cache memory DDR4 at 2133 MHz. It has an x8 PCI Express* 3.0. PCIe interface and supports up to 64 physical SAS.SATA devices** and up to 64 virtual drives. It also supports up to 4 NVMe drives. This controller has a connector to install the drive encryption premium key. The next figures show the connectors for this controller as well as the LED function and placement. ** Physical devices include expanders, and if dual-ported backplanes are being used, each drive counts twice.
Top side
Bottom side
Figure 1. Intel® RMSP3AD160F RAID module layout
17
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide LED description
Figure 2. Intel® RMSP3AD160F RAID Module LED description
18
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.1.1
Intel® RAID Module RMSP3AD160F Dimensions
The next figure shows the dimensions for the Intel® RAID Module RMSP3AD160F.
Figure 3. Intel® RMSP3AD160F RAID module dimensions
19
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.1.2
Intel® RAID Module RMSP3AD160F Electrical, Thermal and Atmospheric Requirements
The Intel® RAID Module RMSP3AD160F has electrical, thermal and atmospheric requirements in order to work properly, if those requirements are not met (operating and non-operating) the functioning of the controller cannot be guaranteed. List of operating conditions for the Intel® RAID module RMSP3AD160F: • • • • •
Power Supply voltage at the 12V rail (from PCI edge connector): 12V ± 8 percent. Power Supply voltage at the 3.3V rail (from PCI edge connector): 13.3V ± 9 percent. Relative humidity range is 20 percent to 80 percent non-condensing Temperature range: 10 °C to +55 °C (with or without the RMFBU module attached) Minimum air flow 200 LFM
List of non-operating conditions (while in storage or in transit) for the Intel® RAID controller RMSP3AD160F: • • •
3.1.3
Relative humidity range is 5 percent to 90 percent non-condensing. Temperature range: –40°C to +70°C without battery backup unit Temperature range: 0°C to +45°C with battery backup unit
Intel® RAID module RMSP3AD160F Power Consumption The following table describes the power consumption of the Intel® RAID module RMSP3AD160F under typical and worst case scenarios: Typical
Maximum
1.33W
1.33W
+ 12
9.21W
9.82W
3.3V Auxiliary
0.03W
0.03W
Total Power
10.57W
11.18W
Power Rail 3.3V
RMFBU Learn 6W 6W
20
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.2
Intel® RAID Controller RMSP3CD080F
The Intel® RAID Module RMSP3CD080F is a full-featured Tri-Mode RAID controller with eight (8) internal ports based on the Avago® SAS3508 RAID-On-Chip (ROC). It supports RAID levels 0, 1, 5,6,10, 50, 60 and includes 4 GB of 72-bit cache memory DDR4 at 2133 MHz. It has an x8 PCI Express* 3.0 PCIe interface and supports up to 240 physical SAS/SATA devices**, two (2) NVMe drives, and up to 64 virtual drives. This controller has a connector to install the Drive Encryption Premium Key. The next figures show the connectors for this controller. ** Physical devices include expanders, and if dual-ported backplanes are being used, each drive counts twice.
Top side
Bottom side
Figure 4. Intel® RMSP3CD160F RAID module layout
21
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Figure 5. Intel® RMSP3CD160F RAID module LED description
22
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.2.1
Intel® RAID Module RMSP3CD160F Dimensions
The next figure shows the dimensions for the Intel® RAID module RMSP3CD160F.
Figure 6. Intel® RMSP3CD160F RAID module dimensions
23
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Intel® RAID Controller RMSP3CD080F Electrical, Thermal, and Atmospheric Requirements The Intel® RAID Module RMSP3CD080F has electrical, thermal and atmospheric requirements in order to work properly, if those requirements are not met (operating and non-operating) the functioning of the controller cannot be guaranteed. List of operating conditions for the Intel® RAID controller RMSP3CD080F: • • • • •
Power Supply voltage at the 12V rail (from PCI edge connector): 12V ± 8 percent. Power Supply voltage at the 3.3V rail (from PCI edge connector): 13.3V ± 9 percent. Relative humidity range is 20 percent to 80 percent non-condensing Temperature range: 10 °C to +55 °C (with or without the RMFBU module attached) Minimum air flow 200 LFM
List of non-operating conditions (while in storage or in transit) for the Intel® RAID module RMSP3CD080F: • • •
3.2.2
Relative humidity range is 5 percent to 90 percent non-condensing. Temperature range: –40°C to +70°C without battery backup unit Temperature range: 0°C to +45°C with battery backup unit
Intel® RAID module RMSP3CD080F Power Consumption The following table describes the power consumption of the Intel® RAID module RMSP3AD160F under typical and worst case scenarios: Power Rail 3.3V
Maximum
RMFBU Learn
1.33W
+ 12
9.82W
3.3V Auxiliary
0.03W
Total Power
11.18W
6W 6W
24
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.3
Intel® RAID module RMSP3HD080E
The Intel® RAID module RMSP3HD080E is an entry-level Tri-Mode RAID controller with eight (8) internal ports based on the Avago® SAS3508 SAS I/O Controller (IOC). It supports RAID levels 0, 1,5 and 10. It has an x8 PCI Express* 3.0 PCIe interface and supports up to 63 physical devices** and up to 32 virtual drives. The next figure describes the connectors for this controller. ** Physical devices include expanders, and if dual-ported backplanes are being used, each drive counts twice.
Top side
Bottom side
Figure 7. Intel® RMSP3HD080E RAID module layout
25
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Figure 8. Intel® RMSP3HD080E RAID Module LED description
26
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.3.1
Intel® RAID Module RMSP3HD080E Dimensions
The next figure show the dimensions for the Intel® RAID module RMSP3HD080E.
Figure 9. Intel RMSP3HD080E RAID module dimensions
27
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
3.3.2
Intel® RAID Module RMSP3HD080E Electrical, Thermal and Atmospheric Requirements The Intel® RAID Module RMSP3HD080E has electrical, thermal and atmospheric requirements in order to work properly, if those requirements are not met (operating and non-operating) the functioning of the controller cannot be guaranteed. List of operating conditions for the Intel® RAID module RMSP3HD080E: • • • • •
Power Supply voltage at the 12V rail (from PCI edge connector): 12V ± 8 percent. Power Supply voltage at the 3.3V rail (from PCI edge connector): 13.3V ± 9 percent. Relative humidity range is 20 percent to 80 percent non-condensing Temperature range: 10 °C to +55 °C (with or without the RMFBU module attached) Minimum air flow 200 LFM
List of non-operating conditions (while in storage or in transit) for the Intel® RAID module RMSP3HD080E: • •
3.3.3
Relative humidity range is 5 percent to 90 percent non-condensing Temperature range: –40°C to +70°C without battery backup unit
Intel® RAID Module RMSP3HD080E Power Consumption The following table describes the power consumption of the Intel® RAID module RMSP3AD160F under typical and worst case scenarios: Power Rail 3.3V
Maximum 1.33W
+ 12
9.82W
3.3V Auxiliary
0.03W
Total Power
11.18W
28
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
4.
Connectivity and Drive Support
4.1
Connectivity and Drive Support
The Intel® Tri- Mode RAID Modules have standard female SFF-8643 (Mini-SAS High-Density) connectors to connect the drives and are designed for the Intel® Server Boards and Systems for the next-generation Intel® Xeon® processor product family. Those systems have the appropriate backplane capable of supporting SAS, SATA and NVMe drives.
4.2
Connector Pinout
The Intel® Tri- Mode RAID Modules have standard female SFF-8643 (Mini-SAS High-Density) connectors to connect to drives. The connector pinout follows the SFF-9402 specification. SFF-9402 defines how to share sideband signals between SAS and PCI Express (NVMe). When SAS/SATA drives are connected either as a direct attach through an SFF-8680 bay or through an enclosure, existing 12Gb/s SAS cables and mid-plane connector designs are supported by the RAID module . The next figure shows the pinout for the female SFF-8643 connectors on the controller cards.
Figure 10. Intel® RMSP3AD160F RAID Module SFF-8643 connector
29
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Table 7. SFF-8643 connector pinout Signal Pin# Name
Pin#
Signal Name
Signal Pin# Name
Signal Pin# Name
A1
SB7
B1
SB3 GND
C1
SB4
D1
SB5
A2
SB0
B2
SB1
C2
SB2
D2
SB6
A3
GND
B3
GND
C3
GND
D3
GND
A4
RX1+
B4
RX0+
C4
TX1+
D4
TX0+
A5
RX1-
B5
RX0-
C5
TX1-
D5
TX0-
A6
GND
B6
GND
C6
GND
D6
GND
A7
RX3+
B7
RX2+
C7
TX3+
D7
TX2+
A8
RX3-
B8
RX2-
C8
TX3-
D8
TX2-
A9
GND
B9
GND
C9
GND
D9
GND
Signals on Pins A1, A2, B1, B2, C1, C2, D1 and D2 are the shared sideband signals.
4.3
SAS/SATA Drive Support
The Intel® Tri-Mode RAID Modules are designed to support SAS, SATA and NVMe drives; however, if desired, they can be used to connect only SAS and SATA drives. In this case, standard SAS cables and backplanes can be used (make sure to use only those backplanes which have been tested and listed as compatible hardware). The Intel® Tri-Mode RAID Modules support the ANSI Serial Attached SCSI standard, version 3.0. In addition, the controllers support the SATA III protocol defined by the Serial ATA specification (SAS), version 3.0. Supporting both the SAS interface and the SATA interface, the SAS controller is a versatile controller that provides the backbone of both server and high-end workstation environments. Each port on the RAID Module supports SAS devices, SATA devices, or both, through these protocols: • • • •
SAS Serial SCSI Protocol (SSP), which enables communication with other SAS devices SATA, which enables communication with other SATA devices Serial Management Protocol (SMP), which communicates topology management information directly with an attached SAS expander device, and Serial Tunneling Protocol (STP), which enables communication with SATA devices through an attached expander.
SAS technology brings a wealth of options and flexibility with the use of SAS devices and SATA devices within the same storage infrastructure. However, SAS devices and SATA devices bring individual characteristics that make each one a more suitable choice depending on the requirements of the given operating environment and storage needs. The Intel® Tri-Mode modules provides the flexibility to combine these two (2) storage technologies on the same controller and within the same enclosure. Note: combining SAS drives and SATA drives within the same virtual drive is allowed on some controllers but Intel discourages this practice.
30
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
4.4
Intel® 12 Gb/s SAS 3.0 Expander Support
For system configurations that require more physical SAS/SATA drives then the controller’s number of ports, the Intel® Tri-Mode RAID Modules can support the following Intel® RAID Expanders: Intel Product Code
Product Description
iPC – RES3FV288
• • • • •
Intel® SAS Expander RES3FV288
Kit includes: (1) SAS Expander card, (2) HD-HD 250mm Expander-to-RAID card cables, and PCI brackets for low profile and full height.
iPC – RES3TV360 • • • • •
Intel® SAS Expander RES3TV360
SAS 3.0 12 Gb/s expander Featuring 6Gbps data aggregation for 12Gbps data transfer with 6Gb/s devices Low Profile MD2 PCIe* add-in card form factor 28 internal ports and 8 external ports Power from PCIe x1 HD Mini-SAS 8643 Connectors
SAS 3.0 12 Gb/s expander Featuring 6Gbps data aggregation for 12Gbps data transferwith 6Gb/s devices Internal mount mid-plane form factor 36 internal ports supporting point-to-pont 12, 6, and 3 Gb/s data transfer rates RA 4-pin power connector HD Mini-SAS 8643 connectors
Kit includes: (1) SAS expander card; (1) 130mm power cable; (1 set) Expander-to-backplane cables: (4) HD-HD 165mm, (1) HD-HD 300mm, (1) HD-HD 250mm, (3) Rubber Pads, and mounting screws.
Figure 11. Supported Intel® SAS expander options
4.4.1
SAS Expander Configuration for the Intel® RMSP3AD160F RAID Module
The SAS ports of the Intel® RMSP3AD160F RAID Module are driven by two (2) SAS cores and therefore, are divided into two (2) separate SAS domains: Domain 1 and Domain 2. One or two SAS connectors within a common domain can be cabled to a single SAS Expander Card when cabling the RAID Controller to a SAS Expander. Note: Mixing SAS ports from different domains to a single SAS expander card is not supported.
Figure 12. RAID module RMS3PAD160 SAS port domain identification 31
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Supported Intel SAS Expanders include several multiport mini-SAS HD (8643) connectors. Some are used as output connectors to a backplane while others are used as input connectors from the RAID Module. The following diagrams identify the connector types for each supported SAS expander card.
Figure 13. SAS ports for the RES3FV288
Figure 14. SAS ports for the RES3TV360
Input Cable Configuration NOTES: The SAS Expander cards identified above can support one (1) or two (2) Input SAS port cables. When routing two (2) input SAS port cables from the RAID Module, use cables from the same SAS domain, as illustrated on the previous page.
Important notice: Be careful not to connect a SAS expander to a RAID module port configured for NVMe use.
32
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
4.5
NVMe Drive Support
The Intel® Tri-Mode RAID controllers are designed to support SAS, SATA and NVMe drives; however, if desired, they can be used to connect only NVMe drives. Note1: At launch time no mixed mode is allowed, this means that either SAS/SATA or NVMe drives can be used but not the combination of the two. The mixed mode will be supported at a later firmware version. The support for NVMe drives is limited to the U.2 (SFF-8639) form factor, connected through a supported backplane using a specially designed Tri-Mode cable. This cable has one (1) dual SF- SFF-8643 (Mini-SAS High-Density) on one end and two (2) OCuLink connectors on the other end to connect to the backplane (the backplane too has both, SF- SFF-8643 and OCuLink connectors). The Intel Part Number for this cable is AXXCBL700HDCV and it connects up to two NVMe drives. Due to limitations on the AXXCBL700HDCV cable, it is only supported on the 2U systems. Note2: Previous generation servers like the R2000WT family or the S2600CW family provide support for NVME drives using a special NVMe kit which includes a backplane. This backplane only has SFF-8643 (MiniSAS HD) connectors and is NOT compatible with the Tri-Mode RAID Modules. Note 3: Using the cable AXXCBL700HDCV on a RAID controller other than the Tri-Mode RAID controllers can damage your equipment. Only use the cables intended for those controllers. The next figures show how to connect the AXXCBL700HDCV cable.
Figure 15. Connecting the AXXCBL700HDCV to the backplane 33
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Figure 16. Connecting the AXXCBL700HDCV cable to the RAID module
34
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
5.
Hardware Installation
5.1
Intel® RAID Module Installation
5.1.1
Requirements
The following items are required to install an Intel® RAID Module: • • • •
Intel® RAID Module. Intel server board-based server system with an empty PCIe slot and a supported backplane Internal Tri-Mode data cables. These cables have one (1) dual SF- SFF-8643 on one end and two (2) OCuLink connectors on the other end. SAS, SATA or NVMe drives.
5.1.2
Packing List
One (1) Intel® RAID Module w/snap-on bumper (pre-installed) Four (4) White Plastic Barrel Stand-offs Four (4) White Plastic Locking Pins with pull-tabs Note: Intel® RAID Products do not include data cables. Appropriate Tri-Mode data cables may be included with the server system or must be purchased separately.
5.1.3 1. 2. 3. 4. 5.
Installation Instructions
Unpack the Intel® RAID Module. Unpack and remove the RAID module. Inspect it for damage. If it appears damaged, contact the Intel Customer and Technical Support representative. Turn off the power to the computer and disconnect the AC power cord. Remove the computer cover. Refer to the system documentation for instructions. Install the barrel standoffs. a) Locate the 80-pin SAS module connector (mezzanine connector) on the server board. See the server board documentation to find where it’s located. b) Insert the barrel standoffs into the matching holes in the server board.
Figure 17. Barrel standoff placement and installation 6.
35
Install the Intel® RAID module. a) Align the module mounting holes over the barrel stand-offs. b) Press down firmly until the 80-pin Server Board Interface connector underneath the RAID module is fully engaged with the mezzanine connector on the server board and the module is firmly seated over each barrel standoff. c) Insert a locking pin into each barrel standoff.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Figure 18. Intel® RAID module placement and installation 7.
Install the SAS and / or SATA drives in the host computer case. Refer to the documentation for the devices for any pre-installation configuration requirements. 8. Connect the internal SAS / SATA data cables to appropriate drives/backplane/or expander card. 9. If NVMe drives are to be used, connect the AXXCBL700HDCV cable to the appropriate backplane. 10. Carefully route the SAS / SATA / NVMe data cables back to the Intel® RAID Module. 11. Attach the SAS/SATA / NVMe data cables to the Intel® RAID Module. 12. Reinstall the computer cover, and reconnect the AC power cords to the system. The hardware installation is now complete and the Intel® RAID Module is ready to be configured. For complete Intel® RAID Module configuration information, refer to the Intel® RAID Software User Guide for full featured and entry level RAID controllers available to download from the following Intel website: http://www.intel.com/support. NOTE: The Intel Tri-Mode controllers are designed to work on systems configured for optimized UEFI boot mode. There is no built-in configuration utility for these controllers when the system is configured for legacy boot mode. Some controllers like RMSP3HD080E will not work when the system they are installed on is configured for legacy boot mode. 36
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
6.
Safety and Regulatory (Class A)
Intel® RAID products typically have a variety of individual component level certifications; however, final regulatory compliance is based on the combination of the RAID card with an Intel server system. Intended Application – The RAID products are evaluated as Information Technology Equipment (ITE) as part of Intel’s server chassis systems. These products are intended to be into Intel server systems to be installed in offices, schools, computer rooms, and similar commercial-type locations. The suitability of this product for other product categories and environments other than an ITE application (such as medical, industrial, telecommunications, NEBS, residential, alarm systems, test equipment, etc.) may require further evaluation. Product Safety and EMC Compliance noted below is based on the RAID product with an Intel server.
6.1 • • • • •
6.2 • • • • • • • • •
6.3
Product Safety Compliance UL60950 – CSA 60950(USA / Canada) EN60950 (Europe) IEC60950 (International) CB Certificate & Report, IEC60950 (report to include all country national deviations) CE - Low Voltage Directive 2006/95/EC (Europe)
Product EMC Compliance – Class A Compliance FCC /ICES-003 - Emissions (USA/Canada) Verification CISPR 22 – Emissions (International) EN55022 - Emissions (Europe) EN55024 - Immunity (Europe) CE – EMC Directive 2004/108 EC (Europe) VCCI Emissions (Japan) AS/NZS 3548 Emissions (Australia / New Zealand) BSMI CNS13438 Emissions (Taiwan) KC Certification (Korea)
Product Environmental Compliance
Intel has a system in place to restrict the use of banned substances in accordance with worldwide regulatory requirements. A material declaration data sheet is available for Intel products. For information on material restrictions and compliance, see Intel’s Environmental Product Content Specification at http://supplier.intel.com/ehs/environmental.htm. •
• • • •
37
Europe - European Directive 2002/95/EC o Restriction of Hazardous Substances (RoHS) Threshold limits and banned substances are noted below. Quantity limit of 0.1% by mass (1000 PPM) for: Lead, Mercury, Hexavalent Chromium, Polybrominated Biphenyls Diphenyl Ethers (PBB/PBDE) Quantity limit of 0.01% by mass (100 PPM) for: Cadmium • California Code of Regulations, Title 22, Division 4.5, Chapter 33: Best Management Practices for Perchlorate Materials China – Restriction of Hazardous Substances (China RoHS) WEEE Directive (Europe) Packaging Directive (Europe) REACH Directive (Europe)
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
7.
Intel® RAID Maintenance Free Backup Unit AXXRMFBU7 (RMFBU)
7.1
Intel® RAID Maintenance Free Backup Unit AXXRMFBU7
Intel® RAID Controllers and Intel® RAID Modules provide reliability, high performance, and fault-tolerant disk subsystem management. A complete fault-tolerant strategy requires protection of all data, including the unwritten cached data in the RAID card’s RAM cache. If power is lost, the data in the RAM cache is lost. To avoid losing this data, a RAID Maintenance Free Backup Unit (RMFBU) can be added to the configuration. During normal system operation, the RMFBU monitors the voltage level of the DRAM of the Intel® RAID Controller or Intel® RAID Module. If the voltage drops below a predefined level due to an AC power failure or brief power outage, the RMFBU protects the integrity of the cached data by providing sufficient back-up power to offload the data from the RAID RAM to the NAND flash. When the voltage level returns to an acceptable level, the RAID RAM is recovered from flash, and all pending writes to storage devices are completed without losing any data. The cache memory available on Intel® RAID Controllers and Intel® RAID Modules can improve the overall system performance. Writing data to the controller’s cache memory is much faster than writing data to a storage device. Write operations appear to complete very quickly at the software application level. The Intel® RAID Module writes the cached data to the storage device when system activity is low or when the cache is getting full. The risk of using write-back cache is that the cached data can be lost if the AC power fails before it is written to the storage device. This risk factor is eliminated when the Intel® RAID Module has an RMFBU installed. In addition, the RMFBU provides an alternative to using an Uninterruptible Power Supply (UPS) or can act as a second level of fault tolerance when used with a UPS. Furthermore, it eliminates the need for lithium ion (Li-ion) batteries traditionally used to protect DRAM cache memory on PCI RAID controllers. Therefore this is a greener and lower total cost cache protection solution. The RMFBU has built-in functionality to charge the capacitor module automatically and to communicate status information such as voltage, temperature, and current to the host server system. The AXXRMFBU7 RMFBU is a kit consisting of a FBU345 super capacitor bank, a plastic bracket to attach the super capacitor bank to the chassis, and two (2) extender cables, one 605 mm long and the other 930 mm long. The FBU345 consists of a bank of Electric Double-Layer Capacitors (EDLC) or super capacitors capable of storing a high amount of electric energy while active. In the event of a power failure, the FBU345 provides the power needed for the data offload. It also has an over-temperature detection circuitry and a discharge circuitry that discharges the capacitors while disconnected from the RAID controller or when the system on which it is installed is turned off.
38
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
7.2
FBU345 Specifications and Layout
The Table 8. FBU345 specifications shows the specifications for the FBU 345 Supercap. The Figure 19. FBU345 layoutsame device followed by its dimensions and pin description. Item
Value
Super Capacitor Module Operating Temperature
0°C to 55°C
Super Capacitor Module Storage Temperature
0°C to 70°C
Rated Voltage
13.5 VDC
Surge Voltage
14.25 VDC
Super Capacitor Module Capacity
7.6 F
Capacity Tolerance
65 mm x 52 mm
RMFBU5 Cache Off-load Module Mechanical
-0%, +30%
Rated Energy
0.04 Wh
Super Capacitor Module Charge Time
Approximately 2 minutes
Super Capacitor Module Shelf Life
3 years
Super Capacitor Module Operational Life
Intel provides a three-year warranty on the Intel® RMFBU AXXRMFBU7.
Maximum Equivalent Series Resistance (ESR) Weight
190 mOhm 46 g
Table 8. FBU345 specifications The FBU345 is very sensitive to the high operating temperature, and excessive heat may shorten its life. The over temperature detection circuitry sends an event to the RAID controller when the operating temperature is over 55 degrees Celsius, which gets registered in the controller’s log file.
39
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Figure 19. FBU345 layout
FBU 345 Dimensions Width (D) Length (L) Height T
51.0 +/- 1.0 mm 64.0 +/- 1.0 mm 13.1 +/- 0.4 mm
Pin Description Pin # 1 2 3 4 5 6 7 8
Signal EDLC GND GND_ 3.3V P3V3_VDD +EDLC SWBDA_P3V3 SWBCL_P3V3 /Event NC
Color Black Black Red Red Yellow Blue White Empty
40
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
7.2.1
Extender Cable
The extender cable has an 8-pin Molex 43020-0601 connector on one end and a 9-pin Molex 501330-0900 connector on the other end. Two (2) versions of the cable are included in the kit, one 605 mm long and the other 930 mm long. The routing of the cable is shown in Figure 20. Extender cable pinout
Figure 20. Extender cable pinout
7.3
Intel® RAID Maintenance Free Backup Unit Installation
The mounting hardware included with Intel® Accessory Kit AXXRMFBU7 is designed to be compatible for installation in to a supported Intel pedestal and rack mount server system. An alternate attachment method may be needed when installing this accessory into a non-Intel chassis. Intel recommends using industrialgrade Velcro* or other industrial adhesive material as an acceptable option. Refer to the server chassis documentation or discuss an appropriate attachment method with the server chassis manufacturer to ensure the attachment mechanism complies with the chassis requirements. 1. 2.
Place the Super Capacitor Module and the plastic holder front-side-up on a flat, clean, static-free surface. Press the Super Capacitor Module into the plastic holder until the module clicks firmly into place, as shown in the following figure (note that the actual shape of the product may vary).
Figure 21. AXXRMFBU7 mounting assembly 3.
41
Identify the mounting location for the RMFBU assembly. a) In an Intel chassis, align the tabs on the holder with the holes on the mounting plate and slide the holder until it clicks and locks into place. b) In a non-Intel chassis, apply adhesive material to the RMFBU assembly and affix to desired mounting location within the chassis.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
2U System – Air Duct RMFBU Mounting Plate
Figure 22. RMFBU assembly installation (example) 4.
Carefully route the extender cable to the Intel® RAID Module and attach the cable to the matching connector. Use the appropriate cable (605 mm or 930 mm long) that best fits.
Figure 23. Connecting the FBU345 to the RAID module using the extender cable
7.4
Monitoring the Intel® RAID Maintenance Free Backup Unit
Three different utilities can be used to monitor the RMFBU: StorCli, RAID Web Console 3 and HII. This section only describes how to use HII for this purpose. For details on how to monitor using the other utilities, consult the Intel® RAID Utilities User Guide.
42
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
7.4.1
Monitoring the RMFBU with the Human Interface Infrastructure.
The Human Interface Infrastructure (HII) can be used to configure disk arrays and logical drives. It is independent of the operating system and can be accessed at server start-up through the Setup BIOS. The HII can only be accessed when the system is configured for UEFI boot mode. The HII can also be used to monitor the MFBU. Note: Refer to the Intel® RAID Software User Guide for full featured and entry level RAID controllers for for more information on the Human Interface Infrastructure. To view the RMFBU information, do the following: 1. 2. 3. 4.
At boot, press the key when prompted and enter the Setup BIOS. Navigate to Main, Advanced, PCI Configuration, and then UEFI Option ROM Control. Look for the RAID card under the Storage Controller list. Press Enter to get into the Main Menu for the HII Configuration Utility.
Figure 24. HII Dashboard view screen
5.
43
Enter the Main Menu and select Hardware Components to go to the Hardware Component Screen.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Figure 25. HII Hardware Components screen 6.
The Hardware Component Screen shows the Battery Status. Select the Battery Management option.
Figure 26. HII Battery Management screen
7.
The Battery Management screen contains the following information: 44
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide Battery Type
A string that identifies the RMFBU type.
Battery Status
The current status of the RMFBU, normally it should be optimal.
Temperature
The current temperature of the battery pack or supercap
Capacitance
With time, the capacitance decreases, this field shows the current capacitance of the battery pack or supercap.
8.
Select the Advanced field at the bottom of the of the Battery Management Screen.
9.
The Battery Management Screen contains the following information:
45
Manufacturer Serial Number Date of Manufacture Module Version Status Voltage Current Design Capacity Remaining Capacity Auto-learn Mode
The manufacturer of the RMFBU unit. The serial number of the RMFBU unit. The date of manufacture of the RMFBU unit. The identifier of the version of the firmware that controls the RMFBU. The current status of the RMFBU, normally it should be optimal. The current voltage of the RMFBU unit. The amount of current being delivered by the RMFBU. The original capacitance that was intended for the Supercap. The capacitance left in the Supercap. The learning mode currently set for the RMFBU.
Next Learn Cycle Ti
The time and date for the next learn cycle.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Appendix A. Glossary Term BIOS
Description Acronym for Basic Input/Output System. Software that provides basic read/write capability. Usually kept as firmware (ROM-based). The system BIOS on the motherboard of a computer boots and controls the system. The BIOS on your host adapter acts as an extension of the system BIOS.
configuration
Refers to the way a computer is set up, the combined hardware components (computer, monitor, keyboard, and peripheral devices) that make up a computer system, or the software settings that allow the hardware components to communicate with each other.
device driver
A program that permits a microprocessor (through the operating system) to direct the operation of a peripheral device.
domain validation
A software procedure in which a host queries a device to determine its ability to communicate at the negotiated data rate.
DRAM cache memory
Dynamic random access memory (DRAM) is a type of memory typically used for data or program code that a computer processor needs to function. DRAM is a common type of random access memory (RAM) used in personal computers (PCs), workstations, and servers.
drive group
A group of physical drives that combines the storage space on the drives into a single segment of storage space. A hot spare drive does not actively participate in a drive group.
EEPROM
Acronym for Electronically Erasable Programmable Read-Only Memory. It is a memory chip that typically stores configuration information, as it provides stable storage for long periods without electricity and can be reprogrammed. See NVRAM.
EDLC
Electric Double-Layer Capacitors
external SAS device
A SAS device installed outside the computer cabinet. These devices are connected using specific types of shielded cables.
Fusion-MPT architecture
Acronym for Fusion-Message Passing Technology architecture. Fusion-MPT consists of several main elements: Fusion-MPT firmware, the Fiber Channel and SCSI hardware, and the operating system-level drivers that support these architectures. Fusion-MPT architecture offers a single binary, operating system driver that supports both Fiber Channel and SCSI devices.
host
The computer system in which a RAID controller is installed. It uses the RAID controller to transfer information to and from devices attached to the SCSI bus.
host adapter board
hot spare
A circuit board or circuit that provides a device connection to the computer system. An idle, powered on, standby drive that is ready for immediate use in case of drive failure. A hot spare does not contain any user data. A hot spare can be dedicated to a single redundant array or it can be part of the global hot-spare pool for all arrays managed by the controller. When a drive fails, the controller firmware automatically replaces and rebuilds the data from the failed drive to the hot spare. Data can be rebuilt only from virtual drives with redundancy (RAID levels 1, 5, 6, 10, 50, and 60; not RAID level 0), and the hot spare must have sufficient capacity.
internal SAS device
A SAS device installed inside the computer cabinet. These devices are connected by using a shielded cable.
main memory
The part of computer memory that is directly accessible by the CPU (usually synonymous with RAM).
46
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Term
Description
NVRAM
Acronym for nonvolatile random access memory. An EEPROM (electronically erasable read-only memory) chip that stores configuration information. See EEPROM.
PCI
Acronym for peripheral component interconnect. A high-performance, local bus specification that allows the connection of devices directly to computer memory. The PCI Local Bus allows transparent upgrades from 32-bit data path at 33 MHz to 64-bit data path at 33 MHz, and from 32-bit data path at 66 MHz to 64-bit data path at 66 MHz.
PCI Express
peripheral devices
Acronym for peripheral component interconnect Express. A high-performance, local bus specification that allows the connection of devices directly to computer memory. PCI Express is a two-way, serial connection that transfers data on two pairs of point- to-point data lines. PCI Express goes beyond the PCI specification in that it is intended as a unifying I/O architecture for various systems: desktops, workstations, mobile, server, communications, and embedded devices. A piece of hardware (such as a video monitor, drive, printer, or CD-ROM) used with a computer and under the control of the computer. SCSI peripherals are controlled through an Intel® RAID Controller (host adapter). The interface required to transmit and receive data packets transferred across the serial bus.
PHY
RAID
RAID levels
SAS
47
Each PHY can form one side of the physical link in a connection with a PHY on a different SAS device. The physical link contains four wires that form two differential signal pairs. One differential pair transmits signals, while the other differential pair receives signals. Both differential pairs operate simultaneously and allow concurrent data transmission in both, thereceive and the transmit directions. Acronym for Redundant Array of Independent Disks (originally Redundant Array of Inexpensive Disks). An array (group) of multiple independent drives managed together to yield higher reliability, performance, or both exceeding that of a single drive. The RAID array appears to the controller as a single storage unit. I/O is expedited because several drives can be accessed simultaneously. Redundant RAID levels (RAID levels 1, 5, 6, 10, 50, and 60) provide data protection. A set of techniques applied to drive groups to deliver higher data availability, performance characteristics, or both to host environments. Each virtual drive must have a RAID level assigned to it. Acronym for Serial Attached SCSI. A serial, point-to-point, enterprise-level device interface that leverages the proven SCSI protocol set. The SAS interface provides improved performance, simplified cabling, smaller connections, lower pin count, and lower power requirements when compared to parallel SCSI. SAS controllers leverage a common electrical and physical connection interface that is compatible with Serial ATA. The SAS controllers support the ANSI Serial Attached SCSI Standard, Version 2.0. In addition, the controller supports the Serial ATA III (SATA III) protocol defined by the Serial ATA Specification, Version 3.0. Supporting both the SAS interface and the SATA III interface, the SAS controller is a versatile controller that provides the backbone of both server and high-end workstation environments. Each port on the SAS RAID controller supports SAS devices, SATA devices, or both.
SAS device
Any device that conforms to the SAS standard and is attached to the SAS bus by a SAS cable. This includes SAS RAID controllers (host adapters) and SAS peripherals.
SATA
Acronym for Serial Advanced Technology Attachment. A physical storage interface standard, SATA is a serial link that provides point-to-point connections between devices. The thinner serial cables allow for better airflow within the system and permit smaller chassis designs.
SMP
Acronym for Serial Management Protocol. SMP communicates topology management information directly with an attached SAS expander device. Each PHY on the controller can function as an SMP initiator.
Intel® RAID Modules RMSP3AD160F, RMSP3CD080F and RMSP3HD080E Hardware User Guide
Term
Description
SSP
Acronym for Serial SCSI Protocol. SSP enables communication with other SAS devices. Each PHY on the SAS controller can function as an SSP initiator.
STP
Acronym for Serial Tunneling Protocol. STP enables communication with a SATA device through an attached expander. Each PHY on the SAS controller can function as an STP initiator.
stripe
stripe size
striping
strip size
UPS
The portion of a stripe that resides on a single drive. The total drive space consumed by a stripe not including a parity drive. For example, if a stripe contains 64 KB of drive space and has 16 KB of data residing on each drive, the stripe size is 64 KB and the strip size is 16 KB. A larger stripe size produces improved read performance, especially if most of the reads are sequential. For mostly random reads, select a smaller stripe size. Drive striping writes data across two or more drives. Each stripe spans two or more drives but consumes only a portion of each drive. Each drive, therefore, may have several stripes. The amount of space consumed by a stripe is the same on each drive that is included in the stripe. The portion of a stripe that resides on a single drive is a strip, also known as a stripe element. Striping by itself does not provide data redundancy; striping in combination with parity provides data redundancy. The drive space consumed by a strip. For example, if a stripe contains 64 KB of drive space and has 16 KB of data residing on each drive, the stripe size is 64 KB and the strip size is 16 KB. The stripe depth is four (four drives in the stripe). You can specify strip sizes of 8 KB, 16 KB, 32 KB, 64 KB, 128 KB, 256 KB, 512 KB, or 1 MB. Uninterruptible Power Supply. An electrical device that provides power off of a battery when the input power source (AC) fails.
48
Mouser Electronics Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Intel: RMSP3AD160F RMSP3CD080F RMSP3HD080E