Preview only show first 10 pages with watermark. For full document please download

12v 3 Opzv100ft - Mad-elec

   EMBED


Share

Transcript

Tubular Gel Battery -Front Terminal 1 2 V 3 O P z V 1 0 0 F T (1 2 V 1 0 0 A H ) Specification Nominal Voltage 12V Capacity 100.0Ah@10hr to 1.80V/cell Dimension Length Width Container Height Total Height (with Terminal) Approx Weight Approx 39.0 kg (86.0lbs) Container Material ABS 3mm (21.7 inches) 2mm (4.33 inches) 3mm (11.3 inches) 3mm (11.3 inches) 87.5 AH/17.5A (10hr,1.80V/cell,200C/680F) (5hr,1.75V/cell,200C/680F) 75.6 AH/25.2A (3hr,1.75V/cell,200C/680F) 61.1 AH/61.1A (1hr,1.60V/cell,200C/680F) 100.0 AH/10.0A Rated Capacity 551 110 287 287 Max. Discharge Current 800A (5s) Internal Resistance Approx 6.5mÙ Operating Temp.Range Discharge : -20 550C (-4 1310F) Charge : 0 400C (32 1040F ) Storage : -20 500C (-4 1220F) Applications Solar energy, wind energy Electric power, nuclear power Communication Ship, maritime affairs UPS, medical facilities and emergency lighting Situation with high environmental protection and energy-saving Better safety performance and reliability Designed service life of 16 years Initial Charging Current less than20.0A.Voltage Cycle Use 2.35V~2.40V at 200 C(680 F)Temp. Coefficient -5mV/0C No limit on Initial Charging Current Voltage Standby Use 2.25V~2.30V at 200 C(680 F)Temp. Coefficient -3mV/0C <3% per month @ 20 0 C(68 0 F) Self-discharge Main Technical Advantages Plate: positive plate adopts tubular plate which can prevent active material falling, and adopts multi-component alloy frame. have fine corrosion-resisting performance and long service life. Negative plate adopts special radiated structure. Separator: adopt special micro-pore PVC-SiO2 separator from Europe AMER-SIL Company, separator have big porosity and low resistance. Electrolyte: adopts Germany gas silicon dioxide,electrolyte in gel state in the battery without flowing,leakage and lamination can be avoided. Safety valve: adopt Germany technology,constant opening and closing,accumulator case expansion,damage and electrolyte dry up can be avoided. Constant Current Discharge (Amperes) at 20 0C (68 0F ) F.V/Time 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 1.85V/cell 63.6 54.8 46.5 29.5 22.5 18.6 16.1 11.3 9.57 5.12 1.80V/cell 71.4 59.9 51.0 31.9 24.1 19.7 16.9 11.8 10.0 5.35 1.75V/cell 76.8 64.5 54.3 33.5 25.2 20.7 17.5 12.1 10.2 5.46 1.70V/cell 82.2 67.6 57.4 34.7 26.2 21.4 18.0 12.3 10.3 5.53 1.65V/cell 86.0 70.4 59.3 35.9 27.1 21.9 18.4 12.5 10.5 5.59 1.60V/cell 89.2 72.4 61.1 37.1 27.7 22.4 18.8 12.7 10.7 5.65 Constant Power Discharge (Watts/cell) at 20 0C (68 0F ) F.V/Time 30min 1.85V/cell 122.4 1.80V/cell 136.3 1.75V/cell 1.70V/cell 45min 1h 2h 3h 4h 5h 8h 10h 20h 106.3 90.5 57.6 44.0 36.6 31.7 22.4 19.1 10.2 115.2 98.8 62.1 47.0 38.7 33.2 23.4 19.9 10.7 145.3 123.3 104.6 65.0 49.2 40.4 34.4 24.0 20.3 10.9 154.1 128.2 110.0 67.0 50.8 41.6 35.2 24.4 20.5 11.0 1.65V/cell 159.6 132.7 113.0 68.9 52.4 42.5 35.9 24.7 20.8 11.1 1.60V/cell 163.9 135.4 115.8 70.9 53.3 43.3 36.6 25.1 21.1 11.2 Specifications subject to change without notice. 1 Dimensions 287 2 274 2 110 2 46 T6 Terminal 551 Discharge Characteristics 2 Charging Characteristics 25 2.50 A E q u a l i n g c h ar g e vo l t a g e f o r ma x. 16 h o ur s 2.40 0.1C 1 0 Charging time in hours Charge voltage (V/cell) 2.45 2.35 2.30 2.25 F l o a t vo l ta g e +/- 1 % 2.20 2.15 B 20 A B 0.2C 1 0 10 0 2.10 -20 -10 10 0 30 20 0 50 40 50 100 Depth of discharge in % of C10 0 Temperature( C) Charge voltage: A 2.25 V/cell State of charge 100 % For continuous charging we recommend a voltage of 2.25 V. The charging voltage must be compensated to the curve for acontinuously different battery ambient temperature. B 2.40 V/cell State of charge 90 % Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 110 22 100 Life expectancy (year) 20 Available capacity( % ) 90 80 70 C 10 C5 C3 C1 60 50 18 Chargi ng voltage 2 . 2 5 V/ c e l l 16 14 12 10 5 40 30 -20 -15 -10 -5 0 5 10 15 20 A m b i e n t t e m p e ra t u r e ( 25 40 104 50 122 F 0 C O ) B a t t e ry t e m p e ra t u re Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time Residual av erage capacity in % of C10 11 0 % 120 100% 100 Available capacity / % Depeth of Discharge 30 86 20 68 30 90% 80% 100%DOD 50%DOD 80%DOD 30%DOD 60% 40% 0 500 1000 1500 2000 2500 80 10 60 20 20 0 3000 30 40 40 5 10 15 20 25 Storage tim e (months) Num ber of Cycles Sales Office China sales office: HongKong sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd, Add: Workshop C, 33/F, TML Tower, Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Tel:+8 6-755-86036060 (100 lines) New Territories, Hong Kong Fax: +86-755-26067269 Tel: +852 35786666 E-mail:[email protected] Fax: +852 21170016 Http://www.leoch.com Singapore sales office: North America sales office: Europe sales office: Add: NO.1 Tech Park Crescent, Add: 19751 Descartes, Unit A, Add: 9B Wheatstone Park, Waterwells Singapore 638131 Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2 2AQ. Tel:+65 68416629 Fax:+65 68443210 Email [email protected] E-mail: [email protected] 2 Tel: 949-588-5853 UK United Kingdom Fax: 949-588-5966 Tel: +44(0) 1452 729428/1452 729696 E-mail: [email protected] Fax: +44 (0)1452-690125 Http://www.leoch.com E-mail: [email protected] Publication No.:LB-OPZV-06-14 Tubular Gel Battery -Front Terminal 12V 4 OPzV150FT (12V150AH) Specification Nominal Voltage 12V Capacity 150.0Ah@10hr to 1.80V/cell Dimension Length Width Container Height Total Height (with Terminal) Approx Weight Approx 53.0 kg (116.9lbs) Container Material ABS Rated Capacity 549.5 124.5 315.0 315.0 2mm (21.6 inches) 3mm (4.90 inches) 3mm (12.4 inches) 3mm (12.4 inches) 150.0 AH/15.0A (10hr,1.80V/cell,200C/680F) 131.5 A H/26.3A (5hr,1.75V/cell,200C/680F) 83.5 AH/37.9A (3hr,1.75V/cell,200C/680F) 91.7 AH/91.7A (1hr,1.60V/cell,200C/680F) Max. Discharge Current 1200A (5s) Internal Resistance Approx 5.0mÙ Operating Temp.Range Discharge : -20 550C (-4 1310F) Charge : 0 400C (32 1040F ) Storage : -20 500C (-4 1220F) Applications Solar energy, wind energy Electric power, nuclear power Communication Ship, maritime affairs UPS, medical facilities and emergency lighting Situation with high environmental protection and energy-saving Better safety performance and reliability Designed service life of 16 years Initial Charging Current less than30.0A.Voltage Cycle Use 2.35V~2.40V at 200 C(680 F)Temp. Coefficient -5mV/0C No limit on Initial Charging Current Voltage Standby Use 2.25V~2.30V at 200 C(680 F)Temp. Coefficient -3mV/0C <3% per month @ 20 0 C(68 0 F) Self-discharge Main Technical Advantages Plate: positive plate adopts tubular plate which can prevent active material falling, and adopts multi-component alloy frame. have fine corrosion-resisting performance and long service life. Negative plate adopts special radiated structure. Separator: adopt special micro-pore PVC-SiO 2 separator from Europe AMER-SIL Company, separator have big porosity and low resistance. Electrolyte: adopts Germany gas silicon dioxide,electrolyte in gel state in the battery without flowing,leakage and lamination can be avoided. Safety valve: adopt Germany technology,constant opening and closing,accumulator case expansion,damage and electrolyte dry up can be avoided. 0 0 Constant Current Discharge (Amperes) at 20 C (68 F ) F.V/Time 30min 45min 1h 2h 3h 4h 5h 8h 10h 20h 1.85V/cell 95.4 82.2 69.7 44.2 33.7 27.9 24.1 16.9 14.4 7.68 1.80V/cell 107.1 89.8 76.5 47.9 36.1 29.6 25.3 17.7 15.0 8.03 1.75V/cell 115.2 96.8 81.5 50.3 37.9 31.0 26.3 18.2 15.3 8.18 1.70V/cell 123.3 101.4 86.1 52.1 39.3 32.0 27.0 18.5 15.5 8.29 1.65V/cell 129.0 105.6 89.0 53.9 40.7 32.8 27.6 18.8 15.7 8.39 1.60V/cell 133.8 108.6 91.7 55.7 41.6 33.6 28.2 19.1 16.0 8.48 0 0 Constant Power Discharge (Watts/cell) at 20 C (68 F ) 2h 3h 4h 5h 8h 10h 20h 135.8 86.5 66.1 54.9 47.6 33.6 28.6 15.3 148.2 93.1 70.5 58.0 49.8 35.2 29.9 16.0 185.0 157.0 97.4 73.7 60.5 51.6 36.0 30.4 16.3 231.2 192.4 165.0 100.5 76.2 62.4 52.8 36.6 30.8 16.5 1.65V/cell 239.4 199.0 169.4 103.4 78.6 63.7 53.9 37.1 31.2 16.7 1.60V/cell 245.9 203.1 173.7 106.3 80.0 65.0 54.8 37.6 31.6 16.8 F.V/Time 30min 45min 1.85V/cell 183.6 159.4 1.80V/cell 204.5 172.8 1.75V/cell 217.9 1.70V/cell 1h Specifications subject to change without notice. 1 Dimensions 124.5 60 315 2 288 1 16 3 T6-A Terminal M8 549.5 Discharge Characteristics Charging Characteristics 2.50 25 A 2.45 Equaling charge voltage for max. 16 hours 2.40 0.1C 10 Charging time in hours Charge voltage (V/cell) 0.5 2.35 2.30 2.25 Float voltage +/- 1% 2.20 2.15 B 20 A B 0.2C 10 10 0 2.10 -20 -10 30 20 10 0 0 50 40 50 100 Depth of discharge in % of C10 0 Temperature ( C) Charge voltage: For continuous charging we recommend a voltage of 2.25 V. The charging voltage must be compensated to the curve for acontinuously different battery ambient temperature. A 2.25 V/cell B 2.40 V/cell State of charge 100 % State of charge 90 % Effect of Temperature on Long Term Float Life Temperature Effects in Relation to Battery Capacity 110 22 90 80 70 C 10 C5 C3 C1 60 50 20 Life expectancy (year) Available capacity( % ) 100 18 Charging voltage 2.25V/cell 16 14 12 10 5 40 30 -20 -15 -10 -5 5 0 10 15 20 Ambient temperature( 25 20 68 30 ) 40 104 50 122 0 C F O Battery temperature Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time Residual average capacity in % of C10 110% 120 100% Available capacity / % Depeth of Discharge 30 86 90% 80% 100%DOD 80%DOD 50%DOD 30%DOD 60% 40% 0 500 1000 1500 2000 2500 100 80 10 60 20 20 0 3000 30 40 40 5 10 15 20 25 Storage time (months) Number of Cycles Sales Office Sales Office China sales office: HongKong sales office: Singapore sales office: Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd, Add: Workshop C, 33/F, TML Tower, Add: NO.1 Tech Park Crescent, Nanshan,Shenzhen, China. 518052 No. 3 Hoi Shing Road, Tsuen Wan, Singapore 638131 Tel:+8 6-755-86036060 (100 lines) New Territories, Hong Kong Fax: +86-755-26067269 Tel: +852 35786666 E-mail:[email protected] Fax: +852 21170016 Http://www.leoch.com E-mail: [email protected] Tel:+65 68416629 Fax:+65 68443210 Email [email protected] North America sales office: Add: 9B Wheatstone Park, Waterwells Foothill Ranch, CA 92610, USA Business Park, Gloucester, GL2 2AQ. Tel: 949-588-5853 UK United Kingdom Fax: 949-588-5966 Tel: +44(0) 1452 729428/1452 729696 E-mail: [email protected] Http://www.leoch.com 2 Europe sales office: Add: 19751 Descartes, Unit A, Fax: +44 (0)1452-690125 E-mail: [email protected] Publication No.:LB-OPZV-06-14