Transcript
Tubular Gel Battery -Front Terminal
1 2 V 3 O P z V 1 0 0 F T (1 2 V 1 0 0 A H )
Specification Nominal Voltage
12V
Capacity
100.0Ah@10hr to 1.80V/cell
Dimension
Length Width Container Height Total Height (with Terminal)
Approx Weight
Approx 39.0 kg (86.0lbs)
Container Material
ABS
3mm (21.7 inches) 2mm (4.33 inches) 3mm (11.3 inches) 3mm (11.3 inches)
87.5 AH/17.5A
(10hr,1.80V/cell,200C/680F) (5hr,1.75V/cell,200C/680F)
75.6 AH/25.2A
(3hr,1.75V/cell,200C/680F)
61.1 AH/61.1A
(1hr,1.60V/cell,200C/680F)
100.0 AH/10.0A Rated Capacity
551 110 287 287
Max. Discharge Current
800A (5s)
Internal Resistance
Approx 6.5mÙ
Operating Temp.Range
Discharge : -20 550C (-4 1310F) Charge : 0 400C (32 1040F ) Storage : -20 500C (-4 1220F)
Applications Solar energy, wind energy Electric power, nuclear power Communication Ship, maritime affairs UPS, medical facilities and emergency lighting Situation with high environmental protection and energy-saving Better safety performance and reliability Designed service life of 16 years
Initial Charging Current less than20.0A.Voltage
Cycle Use
2.35V~2.40V at 200 C(680 F)Temp. Coefficient -5mV/0C No limit on Initial Charging Current Voltage
Standby Use
2.25V~2.30V at 200 C(680 F)Temp. Coefficient -3mV/0C <3% per month @ 20 0 C(68 0 F)
Self-discharge
Main Technical Advantages Plate: positive plate adopts tubular plate which can prevent active material falling, and adopts multi-component alloy frame. have fine corrosion-resisting performance and long service life. Negative plate adopts special radiated structure. Separator: adopt special micro-pore PVC-SiO2 separator from Europe AMER-SIL Company, separator have big porosity and low resistance. Electrolyte: adopts Germany gas silicon dioxide,electrolyte in gel state in the battery without flowing,leakage and lamination can be avoided. Safety valve: adopt Germany technology,constant opening and closing,accumulator case expansion,damage and electrolyte dry up can be avoided.
Constant Current Discharge (Amperes) at 20 0C (68 0F ) F.V/Time
30min
45min
1h
2h
3h
4h
5h
8h
10h
20h
1.85V/cell
63.6
54.8
46.5
29.5
22.5
18.6
16.1
11.3
9.57
5.12
1.80V/cell
71.4
59.9
51.0
31.9
24.1
19.7
16.9
11.8
10.0
5.35
1.75V/cell
76.8
64.5
54.3
33.5
25.2
20.7
17.5
12.1
10.2
5.46
1.70V/cell
82.2
67.6
57.4
34.7
26.2
21.4
18.0
12.3
10.3
5.53
1.65V/cell
86.0
70.4
59.3
35.9
27.1
21.9
18.4
12.5
10.5
5.59
1.60V/cell
89.2
72.4
61.1
37.1
27.7
22.4
18.8
12.7
10.7
5.65
Constant Power Discharge (Watts/cell) at 20 0C (68 0F ) F.V/Time
30min
1.85V/cell
122.4
1.80V/cell
136.3
1.75V/cell 1.70V/cell
45min
1h
2h
3h
4h
5h
8h
10h
20h
106.3
90.5
57.6
44.0
36.6
31.7
22.4
19.1
10.2
115.2
98.8
62.1
47.0
38.7
33.2
23.4
19.9
10.7
145.3
123.3
104.6
65.0
49.2
40.4
34.4
24.0
20.3
10.9
154.1
128.2
110.0
67.0
50.8
41.6
35.2
24.4
20.5
11.0
1.65V/cell
159.6
132.7
113.0
68.9
52.4
42.5
35.9
24.7
20.8
11.1
1.60V/cell
163.9
135.4
115.8
70.9
53.3
43.3
36.6
25.1
21.1
11.2
Specifications subject to change without notice.
1
Dimensions
287 2 274 2
110 2 46
T6 Terminal
551
Discharge Characteristics
2
Charging Characteristics 25
2.50
A E q u a l i n g c h ar g e vo l t a g e f o r ma x. 16 h o ur s
2.40
0.1C 1 0
Charging time in hours
Charge voltage (V/cell)
2.45
2.35 2.30 2.25 F l o a t vo l ta g e +/- 1 % 2.20 2.15
B
20 A
B
0.2C 1 0
10
0
2.10 -20
-10
10
0
30
20
0
50
40
50
100
Depth of discharge in % of C10
0
Temperature( C) Charge voltage: A 2.25 V/cell State of charge 100 %
For continuous charging we recommend a voltage of 2.25 V. The charging voltage must be compensated to the curve for acontinuously different battery ambient temperature.
B
2.40 V/cell State of charge 90 %
Effect of Temperature on Long Term Float Life
Temperature Effects in Relation to Battery Capacity 110
22 100
Life expectancy (year)
20
Available capacity( % )
90 80 70
C 10 C5 C3 C1
60 50
18
Chargi ng voltage 2 . 2 5 V/ c e l l
16 14 12 10 5
40 30 -20
-15
-10
-5
0
5
10
15
20
A m b i e n t t e m p e ra t u r e (
25
40 104
50 122 F
0
C
O
)
B a t t e ry t e m p e ra t u re
Cycle Life in Relation to Depth of Discharge
General Relation of Capacity VS. Storage Time Residual av erage capacity in % of C10
11 0 %
120
100%
100
Available capacity / %
Depeth of Discharge
30 86
20 68
30
90% 80%
100%DOD
50%DOD
80%DOD
30%DOD
60% 40%
0
500
1000
1500
2000
2500
80
10 60
20
20
0
3000
30
40 40
5
10
15
20
25
Storage tim e (months)
Num ber of Cycles
Sales Office China sales office:
HongKong sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd,
Add: Workshop C, 33/F, TML Tower,
Nanshan,Shenzhen, China. 518052
No. 3 Hoi Shing Road, Tsuen Wan,
Tel:+8 6-755-86036060 (100 lines)
New Territories, Hong Kong
Fax: +86-755-26067269
Tel: +852 35786666
E-mail:
[email protected]
Fax: +852 21170016
Http://www.leoch.com
Singapore sales office:
North America sales office:
Europe sales office:
Add: NO.1 Tech Park Crescent,
Add: 19751 Descartes, Unit A,
Add: 9B Wheatstone Park, Waterwells
Singapore 638131
Foothill Ranch, CA 92610, USA
Business Park, Gloucester, GL2 2AQ.
Tel:+65 68416629 Fax:+65 68443210 Email
[email protected]
E-mail:
[email protected]
2
Tel: 949-588-5853
UK United Kingdom
Fax: 949-588-5966
Tel: +44(0) 1452 729428/1452 729696
E-mail:
[email protected]
Fax: +44 (0)1452-690125
Http://www.leoch.com
E-mail:
[email protected] Publication No.:LB-OPZV-06-14
Tubular Gel Battery -Front Terminal 12V 4 OPzV150FT (12V150AH) Specification Nominal Voltage
12V
Capacity
150.0Ah@10hr to 1.80V/cell
Dimension
Length Width Container Height Total Height (with Terminal)
Approx Weight
Approx 53.0 kg (116.9lbs)
Container Material
ABS
Rated Capacity
549.5 124.5 315.0 315.0
2mm (21.6 inches) 3mm (4.90 inches) 3mm (12.4 inches) 3mm (12.4 inches)
150.0 AH/15.0A
(10hr,1.80V/cell,200C/680F)
131.5 A H/26.3A
(5hr,1.75V/cell,200C/680F)
83.5 AH/37.9A
(3hr,1.75V/cell,200C/680F)
91.7 AH/91.7A
(1hr,1.60V/cell,200C/680F)
Max. Discharge Current
1200A (5s)
Internal Resistance
Approx 5.0mÙ
Operating Temp.Range
Discharge : -20 550C (-4 1310F) Charge : 0 400C (32 1040F ) Storage : -20 500C (-4 1220F)
Applications Solar energy, wind energy Electric power, nuclear power Communication Ship, maritime affairs UPS, medical facilities and emergency lighting Situation with high environmental protection and energy-saving Better safety performance and reliability Designed service life of 16 years
Initial Charging Current less than30.0A.Voltage
Cycle Use
2.35V~2.40V at 200 C(680 F)Temp. Coefficient -5mV/0C No limit on Initial Charging Current Voltage
Standby Use
2.25V~2.30V at 200 C(680 F)Temp. Coefficient -3mV/0C <3% per month @ 20 0 C(68 0 F)
Self-discharge
Main Technical Advantages Plate: positive plate adopts tubular plate which can prevent active material falling, and adopts multi-component alloy frame. have fine corrosion-resisting performance and long service life. Negative plate adopts special radiated structure. Separator: adopt special micro-pore PVC-SiO 2 separator from Europe AMER-SIL Company, separator have big porosity and low resistance. Electrolyte: adopts Germany gas silicon dioxide,electrolyte in gel state in the battery without flowing,leakage and lamination can be avoided. Safety valve: adopt Germany technology,constant opening and closing,accumulator case expansion,damage and electrolyte dry up can be avoided. 0
0
Constant Current Discharge (Amperes) at 20 C (68 F ) F.V/Time
30min
45min
1h
2h
3h
4h
5h
8h
10h
20h
1.85V/cell
95.4
82.2
69.7
44.2
33.7
27.9
24.1
16.9
14.4
7.68
1.80V/cell
107.1
89.8
76.5
47.9
36.1
29.6
25.3
17.7
15.0
8.03
1.75V/cell
115.2
96.8
81.5
50.3
37.9
31.0
26.3
18.2
15.3
8.18
1.70V/cell
123.3
101.4
86.1
52.1
39.3
32.0
27.0
18.5
15.5
8.29
1.65V/cell
129.0
105.6
89.0
53.9
40.7
32.8
27.6
18.8
15.7
8.39
1.60V/cell
133.8
108.6
91.7
55.7
41.6
33.6
28.2
19.1
16.0
8.48
0
0
Constant Power Discharge (Watts/cell) at 20 C (68 F ) 2h
3h
4h
5h
8h
10h
20h
135.8
86.5
66.1
54.9
47.6
33.6
28.6
15.3
148.2
93.1
70.5
58.0
49.8
35.2
29.9
16.0
185.0
157.0
97.4
73.7
60.5
51.6
36.0
30.4
16.3
231.2
192.4
165.0
100.5
76.2
62.4
52.8
36.6
30.8
16.5
1.65V/cell
239.4
199.0
169.4
103.4
78.6
63.7
53.9
37.1
31.2
16.7
1.60V/cell
245.9
203.1
173.7
106.3
80.0
65.0
54.8
37.6
31.6
16.8
F.V/Time
30min
45min
1.85V/cell
183.6
159.4
1.80V/cell
204.5
172.8
1.75V/cell
217.9
1.70V/cell
1h
Specifications subject to change without notice.
1
Dimensions
124.5 60
315 2 288 1
16
3
T6-A Terminal
M8
549.5
Discharge Characteristics
Charging Characteristics
2.50
25
A
2.45 Equaling charge voltage for max. 16 hours
2.40
0.1C 10
Charging time in hours
Charge voltage (V/cell)
0.5
2.35 2.30 2.25
Float voltage +/- 1% 2.20 2.15
B
20 A
B
0.2C 10
10
0
2.10 -20
-10
30
20
10
0
0
50
40
50
100
Depth of discharge in % of C10
0
Temperature ( C) Charge voltage:
For continuous charging we recommend a voltage of 2.25 V. The charging voltage must be compensated to the curve for acontinuously different battery ambient temperature.
A 2.25 V/cell
B
2.40 V/cell
State of charge 100 %
State of charge 90 %
Effect of Temperature on Long Term Float Life
Temperature Effects in Relation to Battery Capacity 110
22 90 80 70
C 10 C5 C3 C1
60 50
20
Life expectancy (year)
Available capacity( % )
100
18
Charging voltage 2.25V/cell
16 14 12 10 5
40 30 -20
-15
-10
-5
5
0
10
15
20
Ambient temperature(
25
20 68
30
)
40 104
50 122
0
C F
O
Battery temperature
Cycle Life in Relation to Depth of Discharge
General Relation of Capacity VS. Storage Time Residual average capacity in % of C10
110%
120
100%
Available capacity / %
Depeth of Discharge
30 86
90% 80%
100%DOD
80%DOD
50%DOD
30%DOD
60% 40%
0
500
1000
1500
2000
2500
100 80
10 60
20
20
0
3000
30
40 40
5
10
15
20
25
Storage time (months)
Number of Cycles
Sales Office Sales Office China sales office:
HongKong sales office:
Singapore sales office:
Add:5th Floor,Xinbaohui Bldg.,Nanhai Blvd,
Add: Workshop C, 33/F, TML Tower,
Add: NO.1 Tech Park Crescent,
Nanshan,Shenzhen, China. 518052
No. 3 Hoi Shing Road, Tsuen Wan,
Singapore 638131
Tel:+8 6-755-86036060 (100 lines)
New Territories, Hong Kong
Fax: +86-755-26067269
Tel: +852 35786666
E-mail:
[email protected]
Fax: +852 21170016
Http://www.leoch.com
E-mail:
[email protected]
Tel:+65 68416629 Fax:+65 68443210 Email
[email protected]
North America sales office:
Add: 9B Wheatstone Park, Waterwells
Foothill Ranch, CA 92610, USA
Business Park, Gloucester, GL2 2AQ.
Tel: 949-588-5853
UK United Kingdom
Fax: 949-588-5966
Tel: +44(0) 1452 729428/1452 729696
E-mail:
[email protected] Http://www.leoch.com
2
Europe sales office:
Add: 19751 Descartes, Unit A,
Fax: +44 (0)1452-690125 E-mail:
[email protected]
Publication No.:LB-OPZV-06-14