Preview only show first 10 pages with watermark. For full document please download

13 Seer

   EMBED


Share

Transcript

VSH13 13 SEER SPLIT SYSTEM HEAT PUMP PRODUCT SPECIFICATIONS The VSH13 heat pump features a louvered metal guard that protects the coil from damage and strengthens the unit. Designed for ground-level or rooftop mount, the unit has a base pan that elevates it above the slab for excellent water drainage. Standard Features • • • • • • • • • Energy-efficient compressor R-22 refrigerant-charged for 15’ of refrigerant lines Quiet condenser fan system Copper tube/aluminum fin coil Liquid refrigerant return protection Factory-installed bi-flow liquid line filter dryer Low-pressure switch Time-initiated, temperature-terminated defrost control Service valves with sweat connections and easy-access gauge ports • 13 SEER performance with flowrater expansion device • Ground lug connection • ARI Certified; ETL Listed 13 SEER Cabinet Features 18,000 TO 60,000 BTU/H • Louver design sound control top for quiet operation • Steel louver coil guard • Heavy-gauge, galvanized-steel cabinet with rustresistant screws • Attractive Bahama Beige powder-paint finish with 500-hour salt-spray approval • Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds NOMINAL HEATING CAPACITY Contents 1½ - 5 TONS NOMINAL COOLING CAPACITY 17,200 TO 54,300 BTU/H Nomenclature ........................................................................ 2 Product Specifications ........................................................... 3 Expanded Heating Data ......................................................... 4 Expanded Cooling Data ......................................................... 6 ARI Performance Data ........................................................ 26 Dimensions .......................................................................... 33 Wiring Diagrams .................................................................. 34 Accessories ........................................................................... 35 * Full warranty details available at www.goodmanmfg.com. SS-VSH13 www.goodmanmfg.com 3/09 PRODUCT SPECIFICATIONS NOMENCLATURE V S H 13 18 1 A A 1 2 3 4,5 6,7,8 9 10 11 Brand V GMC Product Family Engineering * Minor Revision Engineering * Major Revision Product Category S Split System Unit Type C Condenser R-22 H Heat Pump R-22 Efficiency 13 13 SEER 1 2 018 024 030 036 Electrical 208/230 V, 1 Phase, 60 Hz 220/240 V, 1 Phase, 50 Hz 1½ Tons 2 Tons 2½ Tons 3 Tons Nominal Capacity 042 3½ Tons 048 4 Tons 060 5 Tons * Neither used for order entry or inventory management. 2 www.goodmanmfg.com SS-VSH13 PRODUCT SPECIFICATIONS SPECIFICATIONS VSH13 0181AA VSH13 0191AA VSH13 0241AA VSH13 0251AA VSH13 0301AA VSH13 0311AA VSH13 0361AA VSH13 0421AA VSH13 0481AA VSH13 0601AA Nominal Cooling (BTU/h) 18,000 18,000 23,000 23,000 28,000 28,000 35,000 40,000 45,000 55,500 Nominal Heating (BTU/h) 16,800 16,800 22,000 22,600 26,800 25,600 32,000 39,000 43,000 55,500 Capacities and Ratings SEER 13 13 13 13 13 13 13 13 13 13 Decibels 78 78 78 78 78 76 80 76 76 77 Compressor RLA 6.2 9.0 9.2 10.9 10.8 12.2 12.2 16.5 17.9 25.0 LRA 34.0 41.0 43.0 54.0 60.0 63.0 73.0 95.0 104.0 148.0 Type Recip Scroll Recip Scroll Recip Scroll Recip Scroll Scroll Scroll Horsepower 1/6 1/6 1/6 1/6 1/6 1/6 ¼ ¼ ¼ 1/6 FLA 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.6 1.6 1.1 Condenser Fan Motor Refrigerant System Refrigerant Line Size¹ Liquid Line Size (“O.D.) ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” Suction Line Size (“O.D.) ¾” ¾” ¾” ¾” ¾” ¾” ⅞” 1⅛” 1⅛” 1⅛” Refrigerant Connection Size Liquid Valve Size (“O.D.) ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” ⅜” Suction Valve Size (“O.D.) ¾” ¾” ¾” ¾” ¾” ¾” ⅞” ⅞” ⅞” ⅞” Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat Sweat 127 115 106 117 153 153 188 213 223 233 0.052 0.052 0.061 0.061 0.068 0.065 0.073 0.082 0.084 0.093 AC Volts 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Frequency-Phase 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 60 Hz/1 Minimum Circuit Ampacity ² 9.3 12.7 13.0 15.1 15.0 16.7 16.9 22.3 27.8 32.3 Max. Overcurrent Protection ³ 15 20 20 20 20 20 20 30 40 50 Valve Type Refrigerant Charge Shipped with Orifice Size Electrical Data Min / Max Volts 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 Electrical Conduit Size ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” ½” or ¾” 193 193 198 207 199 199 207 219 225 266 Ship Weight (lbs) ¹ Tested and rated in accordance with ARI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL. SS-VSH13 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS EXPANDED HEATING DATA VSH130181A* MBh ∆T kW Amps COP EER HI PR LO PR 65 21.1 32.6 1.57 7.3 3.94 13.5 241 83 60 20.0 30.9 1.54 6.8 3.80 13.0 231 77 55 18.8 29.0 1.51 6.4 3.65 12.5 222 72 50 17.6 27.1 1.48 6.0 3.48 11.9 213 66 47 16.8 25.9 1.46 5.8 3.36 11.5 208 62 45 16.3 25.1 1.45 5.7 3.29 11.2 204 60 40 15.1 23.3 1.42 5.4 3.12 10.6 196 55 Outdoor Ambient Temperature 35 30 25 20 17 13.9 10.7 9.9 9.1 8.6 21.5 16.5 15.3 14.1 13.3 1.39 1.30 1.27 1.24 1.23 5.1 4.9 4.7 4.4 4.3 2.94 2.41 2.28 2.14 2.05 10.0 8.2 7.8 7.3 7.0 188 180 172 165 161 49 44 40 35 32 15 8.3 12.8 1.22 4.3 1.99 6.8 158 31 10 7.4 11.5 1.19 4.1 1.83 6.3 152 26 5 6.6 10.2 1.16 3.8 1.66 5.7 146 23 0 5.7 8.9 1.13 3.6 1.49 5.1 140 19 -5 4.9 7.6 1.10 3.3 1.30 4.4 135 17 -10 4.0 6.2 1.08 3.0 1.09 3.7 131 13 60 20.0 30.9 1.63 5.9 3.59 12.3 178 78 55 18.8 29.0 1.60 5.5 3.45 11.8 171 73 50 17.6 27.1 1.57 5.2 3.29 11.2 164 67 47 16.8 25.9 1.55 5.1 3.17 10.8 160 64 45 16.3 25.1 1.54 5.0 3.10 10.6 157 61 40 15.1 23.3 1.51 4.7 2.94 10.0 151 56 Outdoor Ambient Temperature 35 30 25 20 17 13.9 10.7 9.9 9.1 8.6 21.5 16.5 15.3 14.1 13.3 1.48 1.51 1.47 1.44 1.42 4.5 4.3 4.2 4.0 3.9 2.76 2.08 1.96 1.85 1.77 9.4 7.1 6.7 6.3 6.0 145 139 132 127 124 50 45 40 36 33 15 8.3 12.8 1.41 3.9 1.72 5.9 122 32 10 7.4 11.5 1.38 3.7 1.58 5.4 117 27 5 6.6 10.2 1.35 3.5 1.43 4.9 113 23 0 5.7 8.9 1.32 3.3 1.28 4.4 108 20 -5 4.9 7.6 1.28 3.1 1.12 3.8 104 17 -10 4.0 6.2 1.25 2.8 0.94 3.2 101 13 60 26.2 29.6 2.05 8.9 3.73 12.8 250 74 55 24.6 27.8 2.01 8.3 3.58 12.2 240 70 50 23.0 26.0 1.97 7.8 3.42 11.7 230 64 47 22.0 24.8 1.95 7.6 3.30 11.3 224 61 45 21.3 24.1 1.93 7.4 3.23 11.0 220 58 40 19.8 22.4 1.89 7.0 3.06 10.5 212 54 Outdoor Ambient Temperature 35 30 25 20 17 18.3 15.0 13.8 12.7 12.0 20.6 16.9 15.6 14.3 13.6 1.85 1.76 1.73 1.69 1.66 6.6 6.4 6.1 5.8 5.7 2.89 2.48 2.34 2.20 2.11 9.9 8.5 8.0 7.5 7.2 203 195 186 178 174 48 43 38 34 31 15 11.6 13.0 1.65 5.6 2.05 7.0 171 30 10 10.4 11.7 1.61 5.3 1.89 6.4 164 26 5 9.2 10.4 1.57 4.9 1.71 5.9 158 22 0 8.0 9.1 1.53 4.7 1.53 5.2 152 19 -5 6.8 7.7 1.49 4.3 1.34 4.6 146 16 -10 5.6 6.3 1.46 3.9 1.13 3.9 141 13 60 26.9 30.4 2.27 10.3 3.47 11.8 170 71 55 25.3 28.6 2.23 9.7 3.33 11.4 164 66 50 23.7 26.7 2.18 9.1 3.17 10.8 157 61 47 22.6 25.5 2.16 8.8 3.07 10.5 153 58 45 21.9 24.7 2.14 8.7 3.00 10.2 150 55 40 20.3 23.0 2.10 8.2 2.84 9.7 144 51 Outdoor Ambient Temperature 35 30 25 20 17 18.8 17.1 15.7 14.5 13.7 21.2 19.3 17.8 16.4 15.5 2.05 1.90 1.86 1.82 1.80 7.8 7.5 7.2 6.9 6.8 2.67 2.62 2.48 2.33 2.23 9.1 9.0 8.5 8.0 7.6 138 133 127 122 119 45 41 37 32 30 15 13.2 14.9 1.78 6.7 2.17 7.4 117 29 10 11.8 13.4 1.74 6.4 1.99 6.8 112 24 5 10.5 11.8 1.70 6.0 1.81 6.2 108 21 0 9.1 10.3 1.66 5.7 1.61 5.5 103 18 -5 7.8 8.8 1.62 5.3 1.41 4.8 100 15 -10 6.4 7.2 1.58 4.9 1.19 4.0 96 12 60 31.9 28.1 2.36 10.3 3.95 13.5 224 70 55 30.0 26.5 2.32 9.6 3.79 13.0 216 66 50 28.1 24.7 2.27 9.1 3.62 12.4 206 61 47 26.8 23.6 2.24 8.7 3.50 11.9 202 57 45 26.0 22.9 2.22 8.6 3.42 11.7 198 55 40 24.1 21.3 2.18 8.1 3.24 11.1 190 51 Outdoor Ambient Temperature 35 30 25 20 17 22.2 17.4 16.1 14.8 14.0 19.6 15.4 14.2 13.1 12.3 2.13 2.08 2.04 1.99 1.96 7.7 7.3 7.0 6.7 6.5 3.05 2.45 2.31 2.18 2.09 10.4 8.4 7.9 7.4 7.1 182 175 167 160 156 45 41 36 32 30 15 13.5 11.9 1.95 6.4 2.03 6.9 154 29 10 12.1 10.7 1.90 6.1 1.86 6.4 148 24 5 10.7 9.5 1.85 5.7 1.69 5.8 142 21 0 9.4 8.2 1.81 5.3 1.51 5.2 136 18 -5 8.0 7.0 1.76 4.9 1.32 4.5 131 15 -10 6.5 5.8 1.72 4.4 1.11 3.8 127 12 VSH130191A* MBh ∆T kW Amps COP EER HI PR LO PR 65 21.1 32.6 1.66 6.3 3.73 12.7 186 84 VSH130241A* MBh ∆T kW Amps COP EER HI PR LO PR 65 27.7 31.2 2.09 9.6 3.87 13.2 261 80 VSH130251A* MBh ∆T kW Amps COP EER HI PR LO PR 65 28.4 32.1 2.31 11.1 3.59 12.3 178 76 VSH130301A* MBh ∆T kW Amps COP EER HI PR LO PR 65 33.7 29.7 2.41 11.1 4.09 14.0 234 76 High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70 °F indoor dry bulb. 4 www.goodmanmfg.com Amps = Outdoor unit amps (comp.+fan) kW = Total system power SS-VSH13 PRODUCT SPECIFICATIONS EXPANDED HEATING DATA (CONT.) VSH130311A* MBh ∆T kW Amps COP EER HI PR LO PR 65 32.2 28.4 2.55 12.6 3.70 12.6 254 76 60 30.5 26.9 2.49 11.7 3.58 12.2 243 71 55 28.7 25.3 2.44 11.0 3.44 11.8 234 66 50 26.8 23.6 2.39 10.3 3.29 11.2 224 61 47 25.6 22.6 2.36 10.0 3.18 10.9 218 57 45 24.8 21.9 2.33 9.8 3.11 10.6 214 55 40 23.0 20.3 2.28 9.3 2.96 10.1 206 51 Outdoor Ambient Temperature 35 30 25 20 17 21.2 23.7 21.8 20.1 19.0 18.7 20.9 19.3 17.7 16.7 2.23 2.00 1.95 1.90 1.87 8.8 8.5 8.1 7.7 7.6 2.79 3.47 3.28 3.09 2.97 9.5 11.8 11.2 10.6 10.1 198 189 181 174 170 45 41 36 32 30 15 18.3 16.1 1.86 7.5 2.89 9.9 166 29 10 16.4 14.5 1.81 7.1 2.66 9.1 160 24 5 14.5 12.8 1.76 6.7 2.42 8.3 154 21 0 12.7 11.2 1.71 6.3 2.17 7.4 148 18 -5 10.8 9.5 1.66 5.9 1.90 6.5 142 15 -10 8.9 7.8 1.62 5.3 1.61 5.5 137 12 60 38.1 27.7 2.84 12.1 3.92 13.4 221 74 55 35.8 26.0 2.79 11.3 3.76 12.9 212 70 50 33.5 24.3 2.73 10.7 3.59 12.3 203 64 47 32.0 23.2 2.70 10.3 3.46 11.8 198 60 45 31.0 22.5 2.68 10.1 3.39 11.6 194 58 40 28.8 20.9 2.63 9.5 3.21 11.0 187 54 Outdoor Ambient Temperature 35 30 25 20 17 26.6 19.9 18.4 16.9 16.0 19.3 14.5 13.4 12.3 11.6 2.58 2.42 2.37 2.32 2.29 9.1 8.7 8.3 7.9 7.7 3.02 2.41 2.27 2.14 2.05 10.3 8.2 7.8 7.3 7.0 179 172 164 158 154 48 43 38 34 31 15 15.4 11.2 2.27 7.6 1.99 6.8 151 30 10 13.8 10.0 2.22 7.3 1.82 6.2 145 26 5 12.3 8.9 2.17 6.8 1.65 5.7 140 22 0 10.7 7.8 2.12 6.4 1.48 5.0 134 19 -5 9.1 6.6 2.07 5.9 1.29 4.4 129 16 -10 7.5 5.4 2.02 5.4 1.08 3.7 125 13 60 46.4 28.6 3.52 15.5 3.86 13.2 227 70 55 43.7 27.0 3.46 14.5 3.70 12.6 218 65 50 40.8 25.2 3.39 13.6 3.53 12.1 209 60 47 39.0 24.1 3.35 13.1 3.41 11.6 204 57 45 37.8 23.3 3.32 12.9 3.33 11.4 200 54 40 35.1 21.7 3.26 12.1 3.15 10.8 192 50 Outdoor Ambient Temperature 35 30 25 20 17 32.4 28.7 26.5 24.4 23.0 20.0 17.7 16.3 15.0 14.2 3.19 3.08 3.01 2.95 2.91 11.5 11.0 10.5 10.0 9.8 2.97 2.72 2.57 2.42 2.31 10.1 9.3 8.8 8.3 7.9 184 177 169 162 158 45 40 36 32 29 15 22.1 13.7 2.88 9.7 2.25 7.7 155 28 10 19.9 12.3 2.82 9.2 2.06 7.1 149 24 5 17.6 10.9 2.75 8.6 1.87 6.4 144 21 0 15.4 9.5 2.69 8.1 1.67 5.7 138 17 -5 13.1 8.1 2.62 7.4 1.46 5.0 133 15 -10 10.7 6.6 2.56 6.7 1.23 4.2 128 12 60 51.2 29.6 3.77 16.8 3.98 13.6 215 69 55 48.2 27.9 3.70 15.7 3.81 13.0 207 64 50 45.0 26.1 3.63 14.8 3.63 12.4 198 59 47 43.0 24.9 3.59 14.3 3.51 12.0 193 56 45 41.7 24.1 3.56 14.0 3.43 11.7 189 54 40 38.7 22.4 3.49 13.2 3.24 11.1 182 49 Outdoor Ambient Temperature 35 30 25 20 17 35.7 33.6 31.1 28.6 27.0 20.7 19.5 18.0 16.5 15.6 3.42 3.34 3.27 3.20 3.16 12.5 12.0 11.5 10.9 10.7 3.05 2.95 2.78 2.62 2.50 10.4 10.1 9.5 8.9 8.5 175 167 160 154 150 44 40 35 31 29 15 26.0 15.0 3.13 10.5 2.43 8.3 147 28 10 23.3 13.5 3.06 10.0 2.23 7.6 142 24 5 20.7 12.0 3.00 9.3 2.02 6.9 136 20 0 18.0 10.4 2.93 8.8 1.80 6.2 131 17 -5 15.4 8.9 2.86 8.1 1.58 5.4 126 15 -10 12.6 7.3 2.79 7.3 1.32 4.5 121 12 60 66.0 34.0 4.95 21.0 3.91 13.4 244 70 55 62.2 32.0 4.85 19.6 3.75 12.8 235 65 50 58.1 29.9 4.75 18.4 3.58 12.2 225 60 47 55.5 28.5 4.70 17.8 3.46 11.8 219 57 45 53.8 27.7 4.66 17.4 3.38 11.5 215 54 40 50.0 25.7 4.57 16.4 3.20 10.9 207 50 Outdoor Ambient Temperature 35 30 25 20 17 46.1 43.6 40.3 37.1 35.0 23.7 22.4 20.7 19.1 18.0 4.47 4.30 4.21 4.11 4.06 15.6 14.9 14.2 13.5 13.2 3.02 2.97 2.80 2.64 2.52 10.3 10.1 9.6 9.0 8.6 198 190 182 174 170 45 40 36 32 29 15 33.7 17.3 4.02 13.0 2.45 8.4 167 28 10 30.2 15.6 3.93 12.4 2.25 7.7 161 24 5 26.8 13.8 3.84 11.5 2.05 7.0 155 21 0 23.4 12.0 3.75 10.8 1.83 6.2 148 17 -5 20.0 10.3 3.65 10.0 1.60 5.5 143 15 -10 16.3 8.4 3.56 9.0 1.34 4.6 138 12 VSH130361A* MBh ∆T kW Amps COP EER HI PR LO PR 65 40.2 29.2 2.90 13.0 4.07 13.9 230 80 VSH130421A* MBh ∆T kW Amps COP EER HI PR LO PR 65 49.0 30.3 3.59 16.7 4.00 13.7 237 75 VSH130481A* MBh ∆T kW Amps COP EER HI PR LO PR 65 54.1 31.3 3.84 18.1 4.12 14.1 224 74 VSH130601A* MBh ∆T KW AMPS COP EER HI PR LO PR 65 69.8 35.9 5.04 22.7 4.05 13.8 255 75 High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70 °F indoor dry bulb. SS-VSH13 www.goodmanmfg.com Amps = Outdoor unit amps (comp.+fan) kW = Total system power 5 6 www.goodmanmfg.com 59 17.6 0.74 18 1.26 4.8 137 63 17.1 0.70 18 1.26 4.8 136 62 15.8 0.68 19 1.23 4.6 132 60 17.94 0.84 20 1.27 4.8 138 63 17.4 0.80 21 1.27 4.8 137 63 16.1 0.77 22 1.24 4.7 133 61 Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T KW 525 AMPS HI PR LO PR MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR 18.47 0.75 19 1.30 4.9 149 67 17.9 0.71 20 1.29 4.9 147 67 16.5 0.69 20 1.26 4.8 143 65 63 18.3 0.62 15 1.29 4.9 147 67 17.7 0.59 16 1.28 4.9 146 66 16.4 0.57 16 1.25 4.7 142 64 19.99 0.57 15 1.34 5.1 157 74 19.4 0.54 16 1.33 5.1 156 73 17.9 0.52 16 1.30 4.9 151 71 67 20.0 0.43 12 1.33 5.1 156 73 19.4 0.41 12 1.32 5.0 154 72 17.9 0.39 12 1.29 4.9 150 70 21.45 0.36 11 1.38 5.3 164 78 20.8 0.35 11 1.37 5.2 162 78 19.2 0.34 11 1.34 5.1 158 75 71 17.52 0.87 21 1.37 5.2 155 67 17.0 0.83 22 1.36 5.2 154 66 15.7 0.80 22 1.33 5.0 149 64 59 17.2 0.76 18 1.36 5.2 154 66 16.7 0.73 19 1.35 5.1 152 66 15.4 0.70 19 1.32 5.0 148 64 18.04 0.78 19 1.40 5.3 167 71 17.5 0.74 20 1.39 5.3 166 70 16.2 0.71 20 1.35 5.1 161 68 63 17.9 0.64 16 1.39 5.3 165 70 17.3 0.61 16 1.38 5.2 164 70 16.0 0.59 16 1.34 5.1 159 68 19.53 0.59 16 1.44 5.5 177 78 19.0 0.56 16 1.43 5.5 175 77 17.5 0.54 17 1.40 5.3 170 75 67 19.6 0.44 12 1.43 5.5 175 77 19.0 0.42 12 1.42 5.4 173 76 17.5 0.41 12 1.38 5.3 168 74 75ºF 20.96 0.38 11 1.49 5.7 184 83 20.3 0.36 11 1.47 5.7 182 82 18.8 0.35 11 1.44 5.5 177 79 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 17.10 0.89 21 1.45 5.7 177 70 16.6 0.85 22 1.44 5.6 175 69 15.3 0.82 22 1.41 5.5 170 67 59 16.8 0.78 18 1.44 5.6 175 69 16.3 0.75 19 1.43 5.6 173 68 15.1 0.72 19 1.40 5.4 168 66 19.06 0.60 16 1.53 6.0 201 81 18.5 0.57 16 1.52 5.9 199 80 17.1 0.55 17 1.48 5.8 193 78 20.46 0.39 11 1.58 6.2 209 86 19.9 0.37 11 1.57 6.1 207 85 18.3 0.36 11 1.53 6.0 201 83 16.69 0.92 21 1.53 6.0 201 73 16.2 0.88 22 1.51 6.0 199 72 15.0 0.84 22 1.48 5.8 193 70 17.18 0.82 19 1.56 6.2 217 78 16.7 0.78 20 1.55 6.1 214 77 15.40 0.76 20 1.51 6.0 208 75 18.60 0.62 16 1.61 6.4 229 85 18.1 0.59 16 1.59 6.3 226 84 16.7 0.57 17 1.56 6.2 220 81 19.96 0.40 11 1.66 6.6 238 90 19.4 0.38 11 1.65 6.6 236 89 17.9 0.37 12 1.61 6.4 229 87 71 15.85 0.95 21 1.59 6.4 226 77 15.4 0.91 21 1.58 6.4 224 76 14.2 0.88 22 1.54 6.2 217 73 59 15.6 0.84 18 1.57 6.4 224 76 15.1 0.80 19 1.56 6.3 222 75 14.0 0.77 19 1.52 6.1 215 73 16.32 0.85 19 1.62 6.6 244 81 15.8 0.81 20 1.61 6.5 241 81 14.6 0.78 20 1.57 6.3 234 78 63 16.2 0.70 15 1.61 6.5 241 81 15.7 0.67 16 1.60 6.4 239 80 14.5 0.64 16 1.56 6.3 232 77 17.67 0.65 16 1.67 6.8 257 89 17.2 0.62 16 1.66 6.7 255 88 15.8 0.59 16 1.62 6.5 247 85 67 17.7 0.49 12 1.66 6.7 255 88 17.2 0.46 12 1.65 6.7 252 87 15.9 0.45 12 1.61 6.5 245 84 105ºF 18.96 0.42 11 1.73 7.0 268 95 18.4 0.40 11 1.71 7.0 266 94 17.0 0.38 11 1.67 6.8 258 91 71 14.68 0.96 19 1.64 6.8 250 79 14.3 0.92 20 1.63 6.7 248 78 13.2 0.88 20 1.59 6.5 240 76 59 14.4 0.85 17 1.63 6.7 248 78 14.0 0.81 17 1.61 6.7 245 78 12.9 0.78 18 1.58 6.5 238 75 15.12 0.86 18 1.68 7.0 269 84 14.7 0.82 18 1.66 6.9 266 83 13.5 0.79 19 1.62 6.7 258 81 63 15.0 0.71 14 1.66 6.9 266 83 14.5 0.67 15 1.65 6.8 264 83 13.4 0.65 15 1.61 6.6 256 80 16.36 0.65 15 1.73 7.2 284 92 15.9 0.62 15 1.72 7.1 281 91 14.7 0.60 15 1.68 6.9 273 88 67 16.4 0.49 11 1.72 7.1 281 91 15.9 0.47 11 1.70 7.1 279 90 14.7 0.45 12 1.66 6.9 270 87 115ºF 17.56 0.42 10 1.79 7.5 296 98 17.1 0.40 10 1.77 7.4 293 97 15.7 0.38 11 1.73 7.2 285 94 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 17.61 0.80 19 1.48 5.8 190 74 17.1 0.76 20 1.47 5.7 188 73 15.8 0.73 20 1.44 5.6 183 71 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 17.4 19.1 16.4 17.0 18.6 0.65 0.45 0.81 0.67 0.47 16 12 18 16 12 1.47 1.52 1.51 1.55 1.59 5.7 5.9 6.0 6.1 6.3 188 199 199 214 226 73 80 72 77 84 16.9 18.5 15.9 16.5 18.1 0.62 0.43 0.77 0.64 0.45 16 12 19 16 12 1.46 1.50 1.50 1.53 1.58 5.7 5.9 5.9 6.1 6.3 186 197 197 212 224 72 79 72 76 83 15.6 17.1 14.7 15.2 16.7 0.60 0.42 0.74 0.62 0.43 16 12 19 17 13 1.42 1.47 1.47 1.50 1.54 5.5 5.7 5.8 5.9 6.1 181 191 191 206 217 70 77 69 74 81 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130181A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 18.26 0.92 23 1.28 4.9 140 64 17.7 0.88 24 1.27 4.8 138 63 16.4 0.84 24 1.25 4.7 134 61 18.58 0.96 24 1.29 4.9 141 65 18.0 0.92 25 1.28 4.9 140 64 16.6 0.89 26 1.26 4.7 136 62 Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR 18.93 0.93 24 1.32 5.0 152 69 18.4 0.89 25 1.31 5.0 150 68 17.0 0.85 25 1.28 4.9 146 66 63 18.65 0.86 22 1.31 5.0 150 68 18.1 0.82 23 1.30 4.9 149 67 16.7 0.79 23 1.27 4.8 145 65 19.83 0.84 23 1.36 5.2 160 75 19.3 0.80 24 1.35 5.2 159 74 17.8 0.77 24 1.32 5.0 154 72 67 19.93 0.70 19 1.35 5.2 159 74 19.4 0.67 20 1.34 5.1 157 74 17.9 0.64 20 1.31 5.0 153 71 21.16 0.68 20 1.40 5.4 167 80 20.5 0.65 20 1.39 5.3 166 79 19.0 0.63 21 1.36 5.2 161 77 71 21.31 0.52 15 1.39 5.3 166 79 20.7 0.50 16 1.38 5.3 164 78 19.1 0.48 16 1.35 5.1 159 76 18.14 1.00 25 1.39 5.3 158 68 17.6 0.95 26 1.38 5.3 157 68 16.3 0.92 26 1.35 5.1 152 66 59 17.83 0.95 23 1.38 5.3 157 68 17.3 0.91 24 1.37 5.2 155 67 16.0 0.88 24 1.34 5.1 151 65 18.49 0.96 24 1.42 5.4 171 73 18.0 0.92 25 1.41 5.4 169 72 16.6 0.89 26 1.38 5.2 164 70 63 18.22 0.89 22 1.41 5.4 169 72 17.7 0.85 23 1.40 5.3 167 71 16.3 0.82 23 1.36 5.2 162 69 19.37 0.87 23 1.46 5.6 180 79 18.8 0.83 24 1.45 5.6 178 78 17.4 0.80 24 1.42 5.4 173 76 67 19.47 0.73 19 1.45 5.6 178 78 18.9 0.69 20 1.44 5.5 177 78 17.4 0.67 20 1.41 5.4 171 75 75ºF 20.66 0.70 20 1.51 5.8 188 84 20.1 0.67 21 1.50 5.8 186 84 18.5 0.65 21 1.46 5.6 180 81 71 20.81 0.54 15 1.50 5.8 186 84 20.2 0.52 16 1.49 5.7 184 83 18.6 0.50 16 1.45 5.6 179 80 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 17.71 1.00 24 1.48 5.8 180 71 17.2 0.98 26 1.46 5.7 178 70 15.9 0.94 26 1.43 5.6 173 68 18.05 0.99 24 1.51 5.9 194 75 17.5 0.94 25 1.49 5.8 192 75 16.2 0.91 26 1.46 5.7 186 72 20.17 0.72 20 1.60 6.3 214 88 19.6 0.69 21 1.59 6.3 211 87 18.1 0.66 21 1.55 6.1 205 84 17.28 1.00 24 1.55 6.1 205 74 16.8 1.00 26 1.54 6.1 203 74 15.5 0.97 26 1.50 5.9 197 72 17.61 1.00 24 1.58 6.3 221 79 17.1 0.97 25 1.57 6.2 219 78 15.8 0.94 26 1.53 6.1 212 76 18.45 0.92 23 1.63 6.5 233 87 17.9 0.88 24 1.62 6.4 231 86 16.5 0.85 24 1.58 6.3 224 83 19.68 0.75 20 1.69 6.7 243 92 19.1 0.71 21 1.67 6.7 241 91 17.6 0.69 21 1.63 6.5 234 88 16.42 1.00 22 1.61 6.5 231 78 15.9 1.00 24 1.60 6.5 229 77 14.7 1.00 26 1.56 6.3 222 75 59 16.13 1.00 22 1.60 6.5 229 77 15.7 1.00 24 1.59 6.4 226 77 14.5 0.96 24 1.55 6.2 220 74 16.73 1.00 23 1.65 6.7 249 83 16.2 1.00 25 1.64 6.6 246 82 15.0 0.97 26 1.60 6.4 239 80 63 16.49 1.00 22 1.64 6.6 246 82 16.0 0.94 23 1.62 6.6 244 81 14.8 0.90 23 1.58 6.4 236 79 17.52 0.95 23 1.70 6.9 262 91 17.0 0.91 24 1.69 6.8 260 90 15.7 0.88 24 1.65 6.7 252 87 67 17.61 0.80 19 1.69 6.8 260 90 17.1 0.76 20 1.67 6.8 257 89 15.8 0.73 20 1.63 6.6 250 86 105ºF 18.70 0.77 20 1.76 7.2 274 97 18.2 0.74 21 1.74 7.1 271 96 16.8 0.71 21 1.70 6.9 263 93 71 18.83 0.60 15 1.74 7.1 271 96 18.3 0.57 16 1.73 7.0 268 95 16.9 0.55 16 1.69 6.8 260 92 15.21 1.00 21 1.67 6.9 255 81 14.8 1.00 23 1.66 6.9 253 80 13.6 1.00 24 1.61 6.7 245 78 59 14.94 1.00 20 1.66 6.9 253 80 14.5 1.00 22 1.64 6.8 250 79 13.4 0.97 23 1.60 6.6 243 77 15.50 1.00 21 1.71 7.1 275 86 15.0 1.00 23 1.69 7.0 272 85 13.9 0.98 24 1.65 6.8 264 83 63 15.27 1.00 21 1.69 7.0 272 85 14.8 0.94 21 1.68 7.0 269 84 13.7 0.91 22 1.64 6.8 261 82 16.23 0.96 21 1.76 7.3 290 94 15.8 0.92 22 1.75 7.2 287 93 14.5 0.89 23 1.70 7.0 278 90 67 16.32 0.80 18 1.75 7.2 287 93 15.8 0.77 19 1.73 7.2 284 92 14.6 0.74 19 1.69 7.0 276 89 115ºF 17.32 0.78 18 1.82 7.6 302 100 16.8 0.74 19 1.80 7.5 299 99 15.5 0.72 20 1.76 7.3 290 96 71 17.44 0.60 14 1.80 7.5 299 99 16.9 0.57 15 1.79 7.5 296 98 15.6 0.55 15 1.74 7.2 288 95 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 18.91 0.89 23 1.55 6.1 205 82 18.4 0.85 24 1.54 6.0 203 82 16.9 0.82 24 1.50 5.9 197 79 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 17.41 17.79 19.00 20.31 16.98 17.35 18.54 19.82 1.00 0.92 0.74 0.56 1.00 0.94 0.77 0.57 24 22 19 15 23 22 19 16 1.46 1.49 1.54 1.59 1.54 1.57 1.62 1.67 5.7 5.8 6.0 6.3 6.1 6.2 6.4 6.7 178 192 203 211 203 219 231 241 70 75 82 87 74 78 86 91 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 24 23 20 16 24 23 20 16 1.45 1.48 1.53 1.58 1.53 1.56 1.61 1.66 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 177 190 201 209 201 217 229 239 70 74 81 86 73 78 85 90 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 25 23 20 16 25 24 21 16 1.42 1.45 1.49 1.54 1.49 1.52 1.57 1.62 5.5 5.6 5.8 6.0 5.9 6.0 6.2 6.4 171 184 195 203 195 210 222 231 67 72 78 83 71 75 82 88 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130181A*** (CONT.) 7 8 www.goodmanmfg.com 59 17.6 0.74 18 1.25 4.0 136 61 17.1 0.70 18 1.24 4.0 135 61 15.8 0.68 19 1.22 3.9 131 59 17.94 0.84 20 1.26 4.1 137 62 17.4 0.80 21 1.25 4.0 136 61 16.1 0.77 22 1.22 3.9 132 59 Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T 600 kW Amps HI PR LO PR MBh S/T ∆T KW 525 AMPS HI PR LO PR MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T KW 525 AMPS HI PR LO PR 18.47 0.75 19 1.28 4.1 148 66 17.9 0.71 20 1.27 4.1 146 65 16.5 0.69 20 1.25 4.0 142 63 63 18.3 0.61 15 1.27 4.1 146 65 17.7 0.59 16 1.26 4.1 145 64 16.4 0.57 16 1.24 4.0 141 62 19.99 0.57 15 1.32 4.3 156 72 19.4 0.54 16 1.31 4.2 155 71 17.9 0.52 16 1.28 4.1 150 69 67 20.0 0.43 12 1.31 4.2 155 71 19.4 0.41 12 1.30 4.2 153 70 17.9 0.39 12 1.27 4.1 148 68 21.45 0.36 11 1.36 4.4 163 76 20.8 0.35 11 1.35 4.4 161 76 19.2 0.34 11 1.32 4.3 156 73 71 17.52 0.87 21 1.34 4.3 154 65 17.0 0.83 22 1.33 4.3 153 65 15.7 0.80 22 1.31 4.2 148 63 59 17.2 0.76 18 1.33 4.3 153 65 16.7 0.73 19 1.32 4.3 151 64 15.4 0.70 19 1.30 4.2 147 62 18.04 0.78 19 1.37 4.4 166 69 17.5 0.74 20 1.36 4.4 164 69 16.2 0.71 20 1.33 4.3 159 67 63 17.9 0.64 15 1.36 4.4 164 69 17.3 0.61 16 1.35 4.4 163 68 16.0 0.59 16 1.32 4.3 158 66 19.53 0.59 16 1.41 4.6 175 76 19.0 0.56 16 1.40 4.5 173 75 17.5 0.54 17 1.37 4.4 168 73 67 19.6 0.44 12 1.40 4.5 173 75 19.0 0.42 12 1.39 4.5 172 74 17.5 0.41 12 1.36 4.4 167 72 75ºF 20.96 0.38 11 1.45 4.7 183 81 20.3 0.36 11 1.44 4.7 181 80 18.8 0.35 11 1.41 4.5 176 77 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 17.10 0.89 21 1.42 4.7 175 68 16.6 0.85 22 1.41 4.6 174 67 15.3 0.82 22 1.38 4.5 168 65 19.06 0.60 16 1.49 4.9 199 79 18.5 0.57 16 1.48 4.9 197 78 17.1 0.55 17 1.45 4.7 191 76 20.46 0.39 11 1.53 5.1 208 84 19.9 0.37 11 1.52 5.0 206 83 18.3 0.36 11 1.49 4.9 200 81 16.69 0.92 21 1.49 4.9 200 71 16.2 0.88 22 1.47 4.9 198 71 15.0 0.84 22 1.44 4.8 192 68 17.18 0.82 19 1.52 5.0 215 76 16.7 0.78 20 1.50 5.0 213 75 15.40 0.76 20 1.47 4.9 206 73 18.60 0.62 16 1.56 5.2 227 83 18.1 0.59 16 1.55 5.2 225 82 16.7 0.57 17 1.51 5.0 218 79 19.96 0.40 11 1.61 5.4 237 88 19.4 0.38 11 1.60 5.3 234 87 17.9 0.37 12 1.56 5.2 227 85 71 15.85 0.95 21 1.54 5.2 225 75 15.4 0.91 21 1.53 5.2 222 74 14.2 0.88 22 1.50 5.0 216 72 59 15.6 0.84 18 1.53 5.2 222 74 15.1 0.80 19 1.52 5.1 220 73 14.0 0.77 19 1.48 5.0 214 71 16.32 0.85 19 1.57 5.3 242 79 15.8 0.81 20 1.56 5.3 239 79 14.6 0.78 20 1.53 5.2 232 76 63 16.2 0.70 15 1.56 5.3 239 79 15.7 0.67 16 1.55 5.2 237 78 14.5 0.64 16 1.51 5.1 230 75 17.67 0.65 16 1.62 5.5 255 87 17.2 0.62 16 1.61 5.4 253 86 15.8 0.59 16 1.57 5.3 245 83 67 17.7 0.48 12 1.61 5.4 253 86 17.2 0.46 12 1.60 5.4 250 85 15.9 0.45 12 1.56 5.3 243 82 105ºF 18.96 0.41 11 1.67 5.7 266 92 18.4 0.40 11 1.66 5.6 264 91 17.0 0.38 11 1.62 5.5 256 89 71 14.68 0.96 19 1.59 5.5 248 77 14.3 0.92 20 1.58 5.5 246 76 13.2 0.88 20 1.54 5.3 238 74 59 14.4 0.85 17 1.58 5.4 246 76 14.0 0.81 17 1.57 5.4 243 76 12.9 0.78 18 1.53 5.3 236 73 15.12 0.86 18 1.62 5.6 267 82 14.7 0.82 18 1.61 5.6 265 81 13.5 0.79 19 1.57 5.4 257 79 63 15.0 0.71 14 1.61 5.6 264 81 14.5 0.67 15 1.60 5.5 262 80 13.4 0.65 15 1.56 5.4 254 78 16.36 0.65 14 1.67 5.8 282 90 15.9 0.62 15 1.66 5.7 279 89 14.7 0.60 15 1.62 5.6 271 86 67 16.4 0.49 11 1.66 5.7 279 89 15.9 0.47 11 1.65 5.7 277 88 14.7 0.45 12 1.61 5.5 268 85 115ºF 17.56 0.42 10 1.72 6.0 294 95 17.1 0.40 10 1.71 5.9 291 95 15.7 0.38 11 1.67 5.8 283 92 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 17.61 0.80 19 1.45 4.8 189 72 17.1 0.76 20 1.44 4.7 187 71 15.8 0.73 20 1.40 4.6 181 69 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 16.8 17.4 19.1 16.4 17.0 18.6 0.78 0.65 0.45 0.81 0.67 0.47 18 16 12 18 16 12 1.41 1.44 1.48 1.47 1.50 1.55 4.6 4.7 4.9 4.9 5.0 5.2 174 187 197 198 213 225 67 71 78 70 75 82 16.3 16.9 18.5 15.9 16.5 18.1 0.75 0.62 0.43 0.77 0.64 0.45 19 16 12 19 16 12 1.40 1.43 1.47 1.46 1.49 1.54 4.6 4.7 4.8 4.9 5.0 5.1 172 185 195 196 211 222 66 71 77 70 74 81 15.1 15.6 17.1 14.7 15.2 16.7 0.72 0.60 0.42 0.74 0.62 0.43 19 16 12 19 17 13 1.37 1.39 1.43 1.43 1.46 1.50 4.5 4.6 4.7 4.7 4.8 5.0 167 179 189 190 204 216 64 69 75 68 72 79 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130191A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 18.26 0.92 23 1.27 4.1 139 62 17.7 0.88 24 1.26 4.1 137 62 16.4 0.84 24 1.23 4.0 133 60 18.58 0.96 24 1.28 4.1 140 63 18.0 0.92 25 1.27 4.1 139 62 16.6 0.88 26 1.24 4.0 135 60 Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR 18.93 0.93 24 1.30 4.2 151 67 18.4 0.89 25 1.29 4.2 149 66 17.0 0.85 25 1.26 4.1 145 64 63 18.65 0.86 22 1.29 4.2 149 66 18.1 0.82 23 1.28 4.1 148 66 16.7 0.79 23 1.25 4.0 143 64 19.83 0.84 23 1.34 4.3 159 73 19.3 0.80 24 1.33 4.3 158 72 17.8 0.77 24 1.30 4.2 153 70 67 19.93 0.70 19 1.33 4.3 158 72 19.4 0.67 20 1.32 4.3 156 72 17.9 0.64 20 1.29 4.2 151 70 21.16 0.68 20 1.38 4.5 166 78 20.5 0.65 20 1.37 4.4 165 77 19.0 0.63 21 1.34 4.3 160 75 71 21.31 0.52 15 1.37 4.4 165 77 20.7 0.50 16 1.36 4.4 163 76 19.1 0.48 16 1.33 4.3 158 74 18.14 1.00 25 1.36 4.4 157 67 17.6 0.95 26 1.35 4.4 156 66 16.3 0.92 26 1.32 4.3 151 64 59 17.83 0.95 23 1.35 4.4 156 66 17.3 0.91 24 1.34 4.3 154 65 16.0 0.87 24 1.31 4.2 150 63 18.49 0.96 24 1.39 4.5 169 71 18.0 0.92 25 1.38 4.5 168 70 16.6 0.88 26 1.35 4.4 163 68 63 18.22 0.89 22 1.38 4.5 168 70 17.7 0.85 23 1.37 4.4 166 69 16.3 0.82 23 1.34 4.3 161 67 19.37 0.87 23 1.43 4.6 179 77 18.8 0.83 24 1.42 4.6 177 77 17.4 0.80 24 1.39 4.5 172 74 67 19.47 0.73 19 1.42 4.6 177 77 18.9 0.69 20 1.41 4.6 175 76 17.4 0.67 20 1.38 4.4 170 73 75ºF 20.66 0.70 20 1.47 4.8 186 82 20.1 0.67 21 1.46 4.7 185 81 18.5 0.65 21 1.43 4.6 179 79 71 20.81 0.54 15 1.46 4.7 185 81 20.2 0.52 16 1.45 4.7 183 81 18.6 0.50 16 1.42 4.6 177 78 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 17.71 1.00 24 1.44 4.7 179 69 17.2 0.98 26 1.43 4.7 177 68 15.9 0.94 26 1.40 4.6 172 66 18.05 0.99 24 1.47 4.8 193 74 17.5 0.94 25 1.46 4.8 191 73 16.2 0.91 26 1.43 4.7 185 71 20.17 0.72 20 1.56 5.1 212 86 19.6 0.69 21 1.55 5.1 210 85 18.1 0.66 21 1.51 5.0 204 82 17.28 1.00 24 1.51 5.0 204 73 16.8 1.00 26 1.50 5.0 202 72 15.5 0.97 26 1.46 4.9 196 70 17.61 1.00 24 1.54 5.1 219 77 17.1 0.97 25 1.53 5.1 217 77 15.8 0.94 26 1.49 5.0 211 74 18.45 0.92 23 1.58 5.3 232 84 17.9 0.88 24 1.57 5.2 229 84 16.5 0.85 24 1.54 5.1 222 81 19.68 0.75 20 1.63 5.5 242 90 19.1 0.71 21 1.62 5.4 239 89 17.6 0.69 21 1.58 5.3 232 86 16.42 1.00 22 1.57 5.3 229 76 15.9 1.00 24 1.55 5.3 227 75 14.7 1.00 26 1.52 5.1 220 73 59 16.13 1.00 22 1.55 5.3 227 75 15.7 1.00 24 1.54 5.2 225 75 14.5 0.96 24 1.51 5.1 218 72 16.73 1.00 23 1.60 5.4 247 81 16.2 1.00 25 1.59 5.4 244 80 15.0 0.97 26 1.55 5.2 237 78 63 16.49 1.00 22 1.59 5.4 244 80 16.0 0.93 23 1.57 5.3 242 79 14.8 0.90 23 1.54 5.2 235 77 17.52 0.95 23 1.65 5.6 260 88 17.0 0.91 24 1.63 5.5 258 88 15.7 0.88 24 1.60 5.4 250 85 67 17.61 0.80 19 1.63 5.5 258 88 17.1 0.76 20 1.62 5.5 255 87 15.8 0.73 20 1.58 5.4 248 84 105ºF 18.70 0.77 20 1.70 5.8 272 94 18.2 0.74 21 1.68 5.7 269 93 16.8 0.71 21 1.64 5.6 261 90 71 18.83 0.60 15 1.68 5.7 269 93 18.3 0.57 16 1.67 5.7 266 92 16.9 0.55 16 1.63 5.5 258 90 15.21 1.00 21 1.62 5.6 253 79 14.8 1.00 23 1.60 5.5 251 78 13.6 1.00 24 1.57 5.4 243 76 59 14.94 1.00 20 1.60 5.5 251 78 14.5 1.00 22 1.59 5.5 248 77 13.4 0.97 23 1.55 5.4 241 75 15.50 1.00 21 1.65 5.7 273 84 15.0 1.00 23 1.64 5.7 270 83 13.9 0.98 24 1.60 5.5 262 80 63 15.27 1.00 21 1.64 5.7 270 83 14.8 0.94 21 1.62 5.6 267 82 13.7 0.91 22 1.59 5.5 259 80 16.23 0.96 21 1.70 5.9 288 91 15.8 0.92 22 1.69 5.8 285 91 14.5 0.88 23 1.65 5.7 276 88 67 16.32 0.80 18 1.69 5.8 285 91 15.8 0.77 19 1.67 5.8 282 90 14.6 0.74 19 1.63 5.6 274 87 115ºF 17.32 0.78 18 1.75 6.1 300 97 16.8 0.74 19 1.74 6.0 297 96 15.5 0.72 20 1.70 5.9 288 94 71 17.44 0.60 14 1.74 6.0 297 96 16.9 0.57 15 1.72 6.0 294 95 15.6 0.55 15 1.68 5.8 285 93 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 18.91 0.89 23 1.51 5.0 203 80 18.4 0.85 24 1.50 4.9 201 80 16.9 0.82 24 1.47 4.8 195 77 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 17.41 17.79 19.00 20.31 16.98 17.35 18.54 19.82 1.00 0.91 0.74 0.56 1.00 0.94 0.77 0.57 24 22 19 15 23 22 19 16 1.43 1.46 1.50 1.55 1.50 1.53 1.57 1.62 4.7 4.8 4.9 5.1 5.0 5.1 5.2 5.4 177 191 201 210 202 217 229 239 68 73 80 85 72 77 84 89 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 24 23 20 16 24 23 20 16 1.42 1.45 1.49 1.53 1.49 1.52 1.56 1.61 4.7 4.8 4.9 5.1 4.9 5.0 5.2 5.4 175 189 199 208 200 215 227 237 68 72 79 84 71 76 83 88 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 25 23 20 16 25 24 21 16 1.39 1.41 1.46 1.50 1.45 1.48 1.52 1.57 4.5 4.6 4.8 4.9 4.8 4.9 5.1 5.2 170 183 193 202 194 209 220 230 66 70 76 81 69 73 80 85 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130191A*** (CONT.) 9 10 www.goodmanmfg.com 59 22.5 0.74 17 1.64 6.1 137 61 21.9 0.71 17 1.62 6.1 136 60 20.2 0.68 18 1.59 5.9 132 59 22.92 0.84 19 1.65 6.2 139 62 22.3 0.80 20 1.64 6.1 137 61 20.5 0.78 20 1.60 6.0 133 59 Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T 820 kW Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR 23.60 0.75 18 1.68 6.3 149 66 22.9 0.72 18 1.67 6.3 148 65 21.1 0.69 19 1.63 6.1 143 63 63 23.4 0.62 14 1.67 6.3 148 65 22.7 0.59 15 1.66 6.2 146 64 20.9 0.57 15 1.62 6.1 142 62 25.54 0.57 15 1.73 6.5 158 72 24.8 0.54 15 1.72 6.5 156 71 22.9 0.53 15 1.68 6.3 151 69 67 25.6 0.43 11 1.72 6.5 156 71 24.8 0.41 11 1.71 6.4 154 70 22.9 0.40 12 1.67 6.2 150 68 27.41 0.37 10 1.79 6.8 164 76 26.6 0.35 10 1.77 6.7 163 75 24.6 0.34 11 1.73 6.5 158 73 71 22.39 0.87 20 1.77 6.7 156 65 21.7 0.83 20 1.76 6.6 154 64 20.1 0.80 21 1.72 6.4 149 63 59 22.0 0.77 17 1.76 6.6 154 64 21.4 0.73 18 1.74 6.6 153 64 19.7 0.71 18 1.70 6.4 148 62 23.05 0.78 18 1.81 6.8 167 69 22.4 0.75 19 1.79 6.8 166 69 20.7 0.72 19 1.75 6.6 161 67 63 22.8 0.64 15 1.79 6.8 166 69 22.2 0.61 15 1.78 6.7 164 68 20.4 0.59 15 1.74 6.5 159 66 24.95 0.59 15 1.86 7.1 177 76 24.2 0.56 15 1.85 7.0 175 75 22.4 0.54 16 1.80 6.8 170 73 67 25.0 0.45 11 1.85 7.0 175 75 24.3 0.42 12 1.83 6.9 173 74 22.4 0.41 12 1.79 6.7 168 72 75ºF 26.78 0.38 10 1.92 7.3 184 81 26.0 0.36 11 1.91 7.3 183 80 24.0 0.35 11 1.86 7.1 177 77 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 21.85 0.90 20 1.88 7.2 177 68 21.2 0.86 20 1.86 7.2 175 67 19.6 0.82 21 1.82 7.0 170 65 24.36 0.61 15 1.98 7.7 201 79 23.6 0.58 15 1.96 7.6 199 78 21.8 0.56 16 1.91 7.4 193 75 26.14 0.39 10 2.04 7.9 210 84 25.4 0.37 11 2.02 7.9 208 83 23.4 0.36 11 1.98 7.7 201 80 21.32 0.93 20 1.97 7.7 202 71 20.7 0.88 20 1.96 7.7 200 70 19.1 0.85 21 1.91 7.5 194 68 21.95 0.83 18 2.01 7.9 217 76 21.3 0.79 19 2.00 7.9 215 75 19.67 0.76 19 1.95 7.6 208 73 23.76 0.63 15 2.08 8.2 229 83 23.1 0.60 15 2.06 8.1 227 82 21.3 0.58 16 2.01 7.9 220 79 25.50 0.40 10 2.15 8.5 239 88 24.8 0.38 11 2.13 8.4 237 87 22.9 0.37 11 2.08 8.2 229 84 71 20.25 0.96 19 2.05 8.2 227 74 19.7 0.92 20 2.04 8.2 225 74 18.2 0.88 21 1.99 7.9 218 72 59 19.9 0.85 17 2.04 8.2 224 74 19.3 0.81 17 2.02 8.1 222 73 17.8 0.78 18 1.97 7.9 216 71 20.85 0.86 18 2.10 8.4 244 79 20.2 0.82 19 2.08 8.4 242 78 18.7 0.79 19 2.03 8.1 234 76 63 20.6 0.71 15 2.08 8.4 242 78 20.0 0.67 15 2.06 8.3 239 78 18.5 0.65 15 2.01 8.1 232 75 22.57 0.65 15 2.16 8.7 258 86 21.9 0.62 15 2.15 8.6 255 86 20.2 0.60 16 2.09 8.4 247 83 67 22.6 0.49 11 2.15 8.6 255 86 22.0 0.47 11 2.13 8.6 253 85 20.3 0.45 12 2.08 8.3 245 82 105ºF 24.23 0.42 10 2.24 9.0 269 92 23.5 0.40 11 2.22 9.0 266 91 21.7 0.38 11 2.16 8.7 258 88 71 18.76 0.97 18 2.12 8.7 251 77 18.2 0.92 19 2.10 8.6 248 76 16.8 0.89 19 2.05 8.4 241 74 59 18.4 0.85 16 2.10 8.6 248 76 17.9 0.81 16 2.09 8.6 246 75 16.5 0.78 17 2.04 8.3 238 73 19.32 0.87 17 2.17 8.9 270 82 18.8 0.83 17 2.15 8.8 267 81 17.3 0.80 18 2.10 8.6 259 79 63 19.1 0.71 14 2.15 8.8 267 81 18.6 0.68 14 2.13 8.8 264 80 17.1 0.65 14 2.08 8.5 256 78 20.91 0.66 14 2.24 9.2 285 89 20.3 0.63 14 2.22 9.1 282 89 18.7 0.60 14 2.17 8.9 273 86 67 21.0 0.49 10 2.22 9.1 282 89 20.3 0.47 11 2.20 9.1 279 88 18.8 0.45 11 2.15 8.8 271 85 115ºF 22.44 0.42 9 2.31 9.6 297 95 21.8 0.40 10 2.29 9.5 294 94 20.1 0.39 10 2.24 9.2 285 92 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 22.50 0.80 18 1.92 7.4 190 72 21.8 0.77 19 1.90 7.4 189 71 20.2 0.74 19 1.86 7.2 183 69 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 21.5 22.3 24.4 21.0 21.7 23.8 0.79 0.66 0.46 0.81 0.68 0.47 17 15 11 17 15 11 1.86 1.90 1.96 1.96 2.00 2.06 7.2 7.4 7.6 7.7 7.9 8.1 175 189 199 200 215 227 67 71 78 70 75 82 20.9 21.6 23.7 20.4 21.1 23.1 0.75 0.63 0.44 0.78 0.65 0.45 18 15 12 18 15 12 1.85 1.89 1.95 1.94 1.98 2.04 7.1 7.3 7.5 7.6 7.8 8.0 173 187 197 198 213 224 66 71 77 70 74 81 19.3 20.0 21.9 18.8 19.5 21.3 0.73 0.61 0.42 0.75 0.63 0.43 18 15 12 18 16 12 1.80 1.84 1.90 1.89 1.93 2.00 6.9 7.1 7.3 7.4 7.6 7.8 168 181 191 192 206 218 64 68 75 68 72 78 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130241A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 23.33 0.93 22 1.66 6.2 140 62 22.6 0.88 22 1.65 6.2 139 62 20.9 0.85 23 1.61 6.0 135 60 23.74 0.97 23 1.67 6.3 141 63 23.0 0.93 24 1.66 6.2 140 62 21.3 0.89 24 1.62 6.1 136 60 Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T 820 kW Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR 24.19 0.94 23 1.71 6.4 152 67 23.5 0.89 24 1.69 6.4 151 66 21.7 0.86 24 1.66 6.2 146 64 63 23.84 0.87 21 1.69 6.4 151 66 23.1 0.83 21 1.68 6.3 149 66 21.4 0.80 22 1.64 6.2 145 64 25.34 0.84 21 1.76 6.6 161 73 24.6 0.81 22 1.75 6.6 159 72 22.7 0.78 23 1.71 6.4 154 70 67 25.47 0.71 18 1.75 6.6 159 72 24.7 0.67 19 1.73 6.5 158 72 22.8 0.65 19 1.69 6.4 153 69 27.03 0.69 18 1.81 6.9 168 78 26.2 0.65 19 1.80 6.8 166 77 24.2 0.63 20 1.76 6.6 161 75 71 27.22 0.53 14 1.80 6.8 166 77 26.4 0.50 15 1.79 6.8 164 76 24.4 0.49 15 1.74 6.6 159 74 23.18 1.00 23 1.80 6.8 159 66 22.5 0.96 24 1.78 6.7 157 66 20.8 0.92 25 1.74 6.6 152 64 59 22.79 0.96 22 1.78 6.7 157 66 22.1 0.91 23 1.77 6.7 156 65 20.4 0.88 23 1.73 6.5 151 63 23.63 0.97 23 1.84 7.0 171 71 22.9 0.93 24 1.82 6.9 169 70 21.2 0.89 24 1.78 6.7 164 68 63 23.28 0.90 21 1.82 6.9 169 70 22.6 0.86 22 1.81 6.8 167 69 20.9 0.83 22 1.76 6.7 162 67 24.75 0.88 22 1.89 7.2 180 77 24.0 0.84 22 1.88 7.1 179 76 22.2 0.81 23 1.83 6.9 173 74 67 24.87 0.73 18 1.88 7.1 179 76 24.2 0.70 19 1.86 7.1 177 76 22.3 0.67 19 1.82 6.9 172 73 75ºF 26.40 0.71 19 1.95 7.5 188 82 25.6 0.68 19 1.94 7.4 186 81 23.7 0.65 20 1.89 7.2 181 79 71 26.59 0.55 15 1.94 7.4 186 81 25.8 0.52 15 1.92 7.3 184 81 23.8 0.50 15 1.88 7.1 179 78 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 22.63 1.00 23 1.91 7.4 181 69 22.0 0.98 24 1.89 7.3 179 68 20.3 0.95 25 1.85 7.1 173 66 23.07 0.99 23 1.95 7.6 194 73 22.4 0.95 24 1.93 7.5 192 73 20.7 0.91 24 1.89 7.3 187 71 25.78 0.73 19 2.07 8.1 214 85 25.0 0.69 19 2.06 8.0 212 85 23.1 0.67 20 2.01 7.8 206 82 22.08 1.00 22 2.00 7.9 206 72 21.4 1.00 24 1.99 7.8 204 72 19.8 0.98 25 1.94 7.6 197 70 22.51 1.00 22 2.05 8.1 221 77 21.9 0.98 24 2.03 8.0 219 76 20.2 0.94 24 1.98 7.8 213 74 23.57 0.93 22 2.11 8.3 234 84 22.9 0.88 23 2.10 8.3 231 83 21.1 0.85 23 2.04 8.0 224 81 25.15 0.75 19 2.18 8.7 244 90 24.4 0.72 20 2.16 8.6 241 89 22.5 0.69 20 2.11 8.3 234 86 20.98 1.00 21 2.09 8.4 231 76 20.4 1.00 23 2.07 8.3 229 75 18.8 1.00 24 2.02 8.1 222 73 59 20.62 1.00 21 2.07 8.3 229 75 20.0 1.00 22 2.05 8.2 227 74 18.5 0.97 23 2.00 8.0 220 72 21.38 1.00 21 2.13 8.6 249 81 20.8 1.00 23 2.11 8.5 246 80 19.2 0.98 24 2.06 8.3 239 78 63 21.07 1.00 21 2.11 8.5 246 80 20.5 0.94 22 2.10 8.4 244 79 18.9 0.91 22 2.05 8.2 237 77 22.39 0.96 21 2.20 8.9 263 88 21.7 0.92 22 2.18 8.8 260 87 20.1 0.88 23 2.13 8.6 252 85 67 22.51 0.80 18 2.18 8.8 260 87 21.9 0.77 19 2.16 8.7 258 86 20.2 0.74 19 2.11 8.5 250 84 105ºF 23.89 0.78 19 2.27 9.2 274 94 23.2 0.74 19 2.25 9.1 271 93 21.4 0.72 20 2.20 8.9 263 90 71 24.06 0.60 14 2.25 9.1 271 93 23.4 0.57 15 2.24 9.0 269 92 21.6 0.55 15 2.18 8.8 261 89 19.43 1.00 19 2.16 8.9 256 79 18.9 1.00 21 2.14 8.8 253 78 17.4 1.00 22 2.09 8.6 245 75 59 19.10 1.00 19 2.14 8.8 253 78 18.5 1.00 21 2.12 8.7 251 77 17.1 0.98 21 2.07 8.5 243 75 19.81 1.00 20 2.20 9.1 275 84 19.2 1.00 22 2.19 9.0 272 83 17.7 0.99 22 2.13 8.8 264 80 63 19.51 1.00 19 2.19 9.0 272 83 18.9 0.95 20 2.17 8.9 270 82 17.5 0.92 21 2.12 8.7 262 79 20.74 0.97 20 2.28 9.4 290 91 20.1 0.93 21 2.26 9.3 288 90 18.6 0.89 21 2.20 9.1 279 88 67 20.85 0.81 17 2.26 9.3 288 90 20.2 0.77 18 2.24 9.2 285 89 18.7 0.75 18 2.18 9.0 276 87 115ºF 22.13 0.79 17 2.35 9.8 303 97 21.5 0.75 18 2.33 9.7 300 96 19.8 0.72 18 2.27 9.4 291 93 71 22.29 0.61 13 2.33 9.7 300 96 21.6 0.58 14 2.31 9.6 297 95 20.0 0.56 14 2.25 9.3 288 92 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 24.16 0.90 22 2.01 7.8 205 80 23.5 0.86 23 1.99 7.7 203 79 21.7 0.83 23 1.95 7.5 197 77 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 22.24 22.73 24.28 25.96 21.70 22.17 23.69 25.32 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 22 21 18 15 22 21 18 15 1.89 1.93 1.99 2.06 1.99 2.03 2.10 2.16 7.3 7.5 7.7 8.0 7.8 8.0 8.3 8.6 179 192 203 212 204 219 231 241 68 73 79 85 72 76 83 89 21.6 22.1 23.6 25.2 21.1 21.5 23.0 24.6 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 23 22 19 15 23 22 19 15 1.88 1.92 1.98 2.04 1.97 2.01 2.08 2.15 7.2 7.4 7.7 7.9 7.7 7.9 8.2 8.5 177 190 201 210 202 217 229 239 68 72 79 84 71 76 83 88 19.9 20.4 21.8 23.3 19.4 19.9 21.2 22.7 0.90 0.85 0.69 0.52 0.93 0.88 0.71 0.53 23 22 19 15 23 22 19 15 1.83 1.87 1.93 1.99 1.92 1.97 2.03 2.09 7.0 7.2 7.5 7.7 7.5 7.7 8.0 8.3 172 185 195 203 196 210 222 232 66 70 76 81 69 73 80 85 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130241A*** (CONT.) 11 12 www.goodmanmfg.com 59 23.5 0.74 17 1.68 6.7 139 59 22.8 0.71 18 1.66 6.6 138 59 21.1 0.68 18 1.63 6.5 133 57 23.92 0.84 20 1.69 6.7 140 60 23.2 0.80 21 1.68 6.7 139 59 21.4 0.77 21 1.64 6.5 135 58 Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR 24.62 0.75 18 1.72 6.9 151 64 23.9 0.72 19 1.71 6.8 150 63 22.1 0.69 20 1.67 6.7 145 61 63 24.4 0.62 15 1.71 6.8 150 63 23.7 0.59 16 1.70 6.8 148 63 21.8 0.57 16 1.66 6.6 144 61 26.65 0.57 15 1.77 7.1 160 70 25.9 0.54 16 1.76 7.0 158 69 23.9 0.52 16 1.72 6.9 153 67 67 26.7 0.43 11 1.76 7.0 158 69 25.9 0.41 12 1.74 7.0 156 68 23.9 0.39 12 1.71 6.8 152 66 28.61 0.37 10 1.82 7.3 166 74 27.8 0.35 11 1.81 7.3 165 73 25.6 0.34 11 1.77 7.1 160 71 71 23.36 0.87 20 1.81 7.2 158 63 22.7 0.83 21 1.79 7.2 156 63 20.9 0.80 21 1.75 7.0 151 61 59 23.0 0.77 18 1.79 7.2 156 63 22.3 0.73 18 1.78 7.1 154 62 20.6 0.70 19 1.74 6.9 150 60 24.05 0.78 19 1.84 7.4 170 67 23.4 0.74 19 1.83 7.3 168 67 21.6 0.72 20 1.79 7.1 163 65 63 23.8 0.64 15 1.83 7.3 168 67 23.1 0.61 16 1.81 7.3 166 66 21.3 0.59 16 1.77 7.1 161 64 26.03 0.59 15 1.90 7.6 179 74 25.3 0.56 16 1.88 7.5 177 73 23.3 0.54 16 1.84 7.3 172 71 67 26.1 0.44 12 1.88 7.5 177 73 25.3 0.42 12 1.87 7.5 175 72 23.4 0.41 12 1.83 7.3 170 70 75ºF 27.94 0.38 11 1.95 7.8 187 78 27.1 0.36 11 1.94 7.8 185 78 25.0 0.35 11 1.89 7.6 179 75 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 22.80 0.89 20 1.91 7.8 179 66 22.1 0.85 21 1.90 7.7 177 65 20.4 0.82 22 1.85 7.5 172 63 25.41 0.60 15 2.01 8.2 204 76 24.7 0.58 16 1.99 8.1 202 76 22.8 0.56 16 1.95 7.9 196 73 27.28 0.39 11 2.07 8.5 212 81 26.5 0.37 11 2.05 8.4 210 81 24.4 0.36 11 2.01 8.2 204 78 22.25 0.92 20 2.00 8.3 204 69 21.6 0.88 21 1.99 8.2 202 68 19.9 0.85 22 1.94 8.0 196 66 22.91 0.82 19 2.04 8.4 220 74 22.2 0.79 20 2.03 8.4 217 73 20.53 0.76 20 1.98 8.2 211 71 24.79 0.62 15 2.11 8.7 232 80 24.1 0.60 16 2.09 8.6 230 80 22.2 0.57 16 2.04 8.4 223 77 26.61 0.40 11 2.17 9.0 242 86 25.8 0.38 11 2.15 8.9 239 85 23.8 0.37 11 2.10 8.7 232 82 71 21.14 0.96 20 2.08 8.7 230 72 20.5 0.91 21 2.06 8.7 227 72 18.9 0.88 21 2.02 8.4 220 70 59 20.8 0.84 17 2.06 8.7 227 72 20.2 0.80 18 2.05 8.6 225 71 18.6 0.77 18 2.00 8.4 218 69 21.76 0.86 19 2.12 8.9 247 77 21.1 0.82 19 2.11 8.9 245 76 19.5 0.79 20 2.06 8.6 237 74 63 21.5 0.70 15 2.11 8.9 245 76 20.9 0.67 16 2.09 8.8 242 76 19.3 0.65 16 2.04 8.6 235 73 23.55 0.65 15 2.19 9.2 261 84 22.9 0.62 16 2.17 9.1 258 83 21.1 0.60 16 2.12 8.9 251 81 67 23.6 0.49 11 2.17 9.1 258 83 22.9 0.46 12 2.15 9.0 256 83 21.1 0.45 12 2.10 8.8 248 80 105ºF 25.28 0.42 11 2.26 9.5 272 90 24.5 0.40 11 2.24 9.4 269 89 22.7 0.38 11 2.19 9.2 261 86 71 19.58 0.97 19 2.15 9.2 254 75 19.0 0.92 20 2.13 9.1 251 74 17.5 0.89 20 2.08 8.9 244 72 59 19.3 0.85 16 2.13 9.1 251 74 18.7 0.81 17 2.11 9.0 249 73 17.3 0.78 17 2.07 8.8 241 71 20.16 0.86 17 2.19 9.4 273 80 19.6 0.82 18 2.18 9.3 270 79 18.1 0.79 18 2.12 9.1 262 77 63 20.0 0.71 14 2.18 9.3 270 79 19.4 0.68 15 2.16 9.3 267 78 17.9 0.65 15 2.11 9.0 259 76 21.82 0.65 14 2.26 9.7 288 87 21.2 0.62 15 2.24 9.6 285 86 19.6 0.60 15 2.19 9.4 277 84 67 21.9 0.49 11 2.24 9.6 285 86 21.2 0.47 11 2.23 9.5 282 85 19.6 0.45 11 2.17 9.3 274 83 115ºF 23.42 0.42 10 2.33 10.0 301 93 22.7 0.40 10 2.31 10.0 298 92 21.0 0.39 10 2.26 9.7 289 89 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 23.48 0.80 19 1.95 7.9 193 70 22.8 0.76 19 1.93 7.9 191 69 21.0 0.73 20 1.89 7.7 185 67 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 22.4 23.2 25.5 21.9 22.7 24.8 0.79 0.66 0.45 0.81 0.68 0.47 18 15 12 18 15 12 1.90 1.93 1.99 1.99 2.03 2.09 7.7 7.9 8.1 8.2 8.4 8.6 177 191 202 202 217 230 65 69 76 68 73 80 21.8 22.6 24.7 21.2 22.0 24.1 0.75 0.63 0.43 0.77 0.65 0.45 18 16 12 18 16 12 1.88 1.92 1.98 1.97 2.01 2.07 7.6 7.8 8.0 8.1 8.3 8.5 176 189 200 200 215 227 65 69 75 68 72 79 20.1 20.8 22.8 19.6 20.3 22.3 0.72 0.60 0.42 0.75 0.62 0.43 19 16 12 19 16 12 1.84 1.88 1.93 1.93 1.97 2.02 7.5 7.6 7.8 7.9 8.1 8.3 170 183 194 194 209 220 63 67 73 66 70 76 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130251A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 24.34 0.92 22 1.70 6.8 142 61 23.6 0.88 23 1.69 6.7 140 60 21.8 0.85 24 1.65 6.6 136 58 24.77 0.97 24 1.71 6.8 143 61 24.0 0.92 25 1.70 6.8 142 61 22.2 0.89 25 1.66 6.6 138 59 Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR 25.25 0.93 23 1.75 7.0 154 65 24.5 0.89 24 1.73 6.9 153 64 22.6 0.86 25 1.69 6.8 148 63 63 24.87 0.86 21 1.73 6.9 153 64 24.1 0.82 22 1.72 6.9 151 64 22.3 0.80 23 1.68 6.7 147 62 26.44 0.84 22 1.80 7.2 163 71 25.7 0.80 23 1.78 7.1 161 70 23.7 0.77 24 1.74 7.0 156 68 67 26.57 0.70 19 1.78 7.1 161 70 25.8 0.67 19 1.77 7.1 160 70 23.8 0.65 20 1.73 6.9 155 68 28.21 0.68 19 1.85 7.4 170 76 27.4 0.65 20 1.84 7.4 168 75 25.3 0.63 20 1.79 7.2 163 73 71 28.41 0.53 15 1.84 7.4 168 75 27.6 0.50 16 1.82 7.3 166 74 25.5 0.48 16 1.78 7.1 161 72 24.19 1.00 24 1.83 7.3 161 65 23.5 0.96 25 1.82 7.3 159 64 21.7 0.92 26 1.78 7.1 154 62 59 23.78 0.96 23 1.82 7.3 159 64 23.1 0.91 24 1.81 7.2 158 63 21.3 0.88 24 1.77 7.0 153 61 24.66 0.97 24 1.87 7.5 173 69 23.9 0.92 25 1.86 7.4 171 68 22.1 0.89 25 1.81 7.3 166 66 63 24.29 0.90 22 1.86 7.4 171 68 23.6 0.85 23 1.84 7.4 170 67 21.8 0.82 23 1.80 7.2 164 65 25.83 0.87 22 1.92 7.7 183 75 25.1 0.83 23 1.91 7.7 181 74 23.1 0.80 24 1.87 7.5 175 72 67 25.96 0.73 19 1.91 7.7 181 74 25.2 0.70 20 1.90 7.6 179 74 23.3 0.67 20 1.85 7.4 174 71 75ºF 27.55 0.71 19 1.98 8.0 190 80 26.8 0.67 20 1.97 7.9 189 79 24.7 0.65 21 1.92 7.7 183 77 71 27.75 0.55 15 1.97 7.9 189 79 26.9 0.52 16 1.95 7.8 187 78 24.9 0.50 16 1.91 7.7 181 76 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 23.62 1.00 24 1.94 7.9 183 67 22.9 0.98 25 1.92 7.8 181 67 21.2 0.94 26 1.88 7.6 176 65 24.07 0.99 24 1.98 8.1 197 71 23.4 0.95 25 1.96 8.0 195 71 21.6 0.91 25 1.92 7.8 189 69 26.90 0.73 19 2.10 8.6 217 83 26.1 0.69 20 2.08 8.5 214 82 24.1 0.67 21 2.04 8.3 208 80 23.04 1.00 23 2.03 8.4 208 71 22.4 1.00 25 2.02 8.3 206 70 20.6 0.98 26 1.97 8.1 200 68 23.48 1.00 23 2.07 8.6 224 75 22.8 0.98 25 2.06 8.5 222 74 21.0 0.94 25 2.01 8.3 215 72 24.60 0.92 23 2.14 8.8 237 82 23.9 0.88 24 2.12 8.8 234 81 22.0 0.85 24 2.07 8.5 227 79 26.24 0.75 20 2.21 9.1 247 87 25.5 0.71 20 2.19 9.1 244 86 23.5 0.69 21 2.14 8.8 237 84 21.89 1.00 22 2.11 8.9 234 74 21.2 1.00 24 2.10 8.8 232 73 19.6 1.00 25 2.05 8.6 225 71 59 21.51 1.00 21 2.10 8.8 232 73 20.9 1.00 23 2.08 8.7 230 72 19.3 0.97 24 2.03 8.5 223 70 22.31 1.00 22 2.16 9.1 252 79 21.7 1.00 24 2.14 9.0 250 78 20.0 0.98 25 2.09 8.8 242 76 63 21.98 1.00 22 2.14 9.0 250 78 21.3 0.94 22 2.12 8.9 247 77 19.7 0.91 23 2.07 8.7 240 75 23.37 0.96 22 2.22 9.4 266 86 22.7 0.91 23 2.21 9.3 263 85 20.9 0.88 24 2.15 9.0 256 82 67 23.48 0.80 19 2.21 9.3 263 85 22.8 0.76 20 2.19 9.2 261 84 21.0 0.74 20 2.14 9.0 253 82 105ºF 24.93 0.78 19 2.29 9.7 278 91 24.2 0.74 20 2.28 9.6 275 91 22.3 0.71 20 2.22 9.4 267 88 71 25.10 0.60 15 2.28 9.6 275 91 24.4 0.57 16 2.26 9.5 272 90 22.5 0.55 16 2.20 9.3 264 87 20.27 1.00 20 2.18 9.4 259 76 19.7 1.00 22 2.16 9.3 256 76 18.2 1.00 23 2.11 9.0 248 73 59 19.93 1.00 20 2.16 9.3 256 76 19.3 1.00 22 2.15 9.2 254 75 17.9 0.97 22 2.10 9.0 246 73 20.67 1.00 21 2.23 9.6 278 81 20.1 1.00 22 2.21 9.5 276 81 18.5 0.98 23 2.16 9.3 267 78 63 20.36 1.00 20 2.21 9.5 276 81 19.8 0.95 21 2.19 9.4 273 80 18.2 0.91 21 2.14 9.2 265 77 21.64 0.97 21 2.30 9.9 294 89 21.0 0.92 22 2.28 9.8 291 88 19.4 0.89 22 2.22 9.5 282 85 67 21.75 0.81 18 2.28 9.8 291 88 21.1 0.77 18 2.26 9.7 288 87 19.5 0.74 19 2.21 9.5 280 84 115ºF 23.09 0.78 18 2.37 10.2 307 95 22.4 0.75 19 2.35 10.1 304 94 20.7 0.72 19 2.30 9.9 295 91 71 23.25 0.60 14 2.35 10.1 304 94 22.6 0.58 15 2.33 10.0 301 93 20.8 0.56 15 2.28 9.8 292 90 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 25.21 0.89 22 2.04 8.3 208 78 24.5 0.85 23 2.02 8.2 206 77 22.6 0.82 24 1.98 8.0 199 75 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 23.21 23.72 25.34 27.09 22.64 23.14 24.72 26.43 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 23 22 19 15 23 22 19 15 1.92 1.96 2.02 2.08 2.02 2.06 2.12 2.19 7.8 8.0 8.2 8.5 8.3 8.5 8.8 9.1 181 195 206 214 206 222 234 244 67 71 77 82 70 74 81 86 22.5 23.0 24.6 26.3 22.0 22.5 24.0 25.7 0.93 0.88 0.71 0.53 0.96 0.90 0.74 0.55 24 23 20 16 24 23 20 16 1.91 1.95 2.01 2.07 2.00 2.04 2.11 2.17 7.8 7.9 8.2 8.5 8.3 8.4 8.7 9.0 179 193 204 212 204 220 232 242 66 70 76 81 69 74 80 86 20.8 21.3 22.7 24.3 20.3 20.7 22.2 23.7 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 24 23 20 16 24 23 20 16 1.87 1.90 1.96 2.02 1.96 2.00 2.06 2.12 7.6 7.7 8.0 8.2 8.0 8.2 8.5 8.8 174 187 197 206 198 213 225 235 64 68 74 79 67 71 78 83 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130251A*** (CONT.) 13 14 www.goodmanmfg.com 59 27.0 0.75 16 2.04 7.6 141 62 26.6 0.72 17 2.03 7.6 140 62 25.3 0.69 17 2.00 7.4 138 61 27.50 0.85 18 2.05 7.7 143 63 27.1 0.82 19 2.04 7.6 142 63 25.7 0.78 20 2.01 7.5 139 61 Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR 28.31 0.76 17 2.10 7.9 154 67 27.9 0.73 18 2.08 7.8 153 67 26.5 0.70 18 2.05 7.7 150 65 63 28.0 0.63 14 2.08 7.8 152 66 27.6 0.60 15 2.07 7.8 151 66 26.2 0.57 15 2.04 7.6 148 65 30.64 0.58 14 2.16 8.1 162 73 30.2 0.55 15 2.15 8.1 161 73 28.7 0.53 15 2.11 7.9 158 71 67 30.7 0.43 10 2.14 8.1 161 73 30.3 0.42 11 2.13 8.0 160 72 28.7 0.40 11 2.10 7.9 156 71 32.89 0.37 10 2.23 8.4 169 78 32.4 0.36 10 2.22 8.4 168 77 30.8 0.34 10 2.18 8.2 165 76 71 26.86 0.88 19 2.21 8.3 160 67 26.5 0.85 20 2.19 8.3 159 66 25.1 0.81 20 2.16 8.1 156 65 59 26.4 0.78 16 2.19 8.2 159 66 26.0 0.74 17 2.18 8.2 158 66 24.7 0.71 17 2.14 8.0 154 64 27.65 0.79 17 2.25 8.5 173 71 27.2 0.76 18 2.24 8.5 171 70 25.9 0.73 19 2.21 8.3 168 69 63 27.4 0.65 14 2.24 8.4 171 70 27.0 0.62 15 2.22 8.4 170 70 25.6 0.60 15 2.19 8.2 166 68 29.93 0.60 14 2.32 8.8 182 77 29.5 0.57 15 2.31 8.8 181 77 28.0 0.55 15 2.27 8.6 177 75 67 30.0 0.45 11 2.31 8.7 180 77 29.5 0.43 11 2.29 8.7 179 76 28.1 0.41 11 2.26 8.5 176 75 75ºF 32.12 0.38 10 2.40 9.1 190 82 31.6 0.37 10 2.38 9.1 189 82 30.1 0.35 11 2.35 8.9 185 80 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 26.22 0.91 19 2.34 9.0 182 69 25.8 0.87 20 2.33 9.0 181 69 24.5 0.83 20 2.29 8.8 177 67 29.22 0.61 14 2.47 9.6 207 80 28.8 0.59 15 2.45 9.5 206 80 27.3 0.56 15 2.41 9.3 202 78 31.36 0.39 10 2.55 9.9 216 86 30.9 0.38 10 2.53 9.9 215 85 29.4 0.36 11 2.49 9.7 210 83 25.58 0.94 19 2.46 9.7 208 73 25.2 0.90 20 2.45 9.6 206 72 23.9 0.86 20 2.41 9.4 202 71 26.34 0.84 17 2.52 9.9 224 77 25.9 0.80 18 2.50 9.9 222 77 24.65 0.77 19 2.46 9.7 218 75 28.51 0.63 14 2.60 10.3 236 85 28.1 0.61 15 2.58 10.2 234 84 26.7 0.58 15 2.54 10.0 230 82 30.59 0.41 10 2.68 10.6 246 90 30.1 0.39 10 2.67 10.6 244 89 28.6 0.37 11 2.62 10.4 240 88 71 24.30 0.97 18 2.56 10.3 234 76 23.9 0.93 19 2.55 10.2 232 76 22.7 0.89 20 2.51 10.0 227 74 59 23.9 0.85 16 2.54 10.2 231 75 23.5 0.82 17 2.53 10.1 230 75 22.4 0.78 17 2.49 10.0 225 73 25.02 0.87 17 2.62 10.6 251 81 24.6 0.83 18 2.60 10.5 250 81 23.4 0.80 19 2.56 10.3 245 79 63 24.8 0.71 14 2.60 10.5 249 80 24.4 0.68 15 2.58 10.4 247 80 23.2 0.65 15 2.54 10.2 242 78 27.08 0.66 14 2.70 10.9 266 89 26.7 0.63 15 2.69 10.8 264 88 25.3 0.60 15 2.64 10.6 258 86 67 27.1 0.49 11 2.68 10.8 263 88 26.7 0.47 11 2.67 10.7 261 87 25.4 0.45 11 2.62 10.5 256 85 105ºF 29.06 0.42 10 2.79 11.3 277 94 28.6 0.40 10 2.78 11.3 275 94 27.2 0.39 10 2.73 11.1 270 92 71 22.51 0.98 17 2.65 10.9 258 79 22.2 0.94 18 2.64 10.9 256 78 21.1 0.90 19 2.59 10.7 251 77 59 22.1 0.86 15 2.63 10.8 256 78 21.8 0.82 16 2.61 10.8 254 78 20.7 0.79 16 2.57 10.6 249 76 23.17 0.88 16 2.71 11.2 278 84 22.8 0.84 17 2.69 11.1 276 83 21.7 0.80 17 2.65 10.9 270 82 63 22.9 0.72 13 2.69 11.1 275 83 22.6 0.69 14 2.67 11.0 273 82 21.5 0.66 14 2.63 10.8 268 81 25.08 0.66 13 2.80 11.6 293 92 24.7 0.63 14 2.78 11.5 291 91 23.5 0.61 14 2.74 11.3 286 89 67 25.1 0.50 10 2.77 11.5 290 91 24.8 0.48 10 2.76 11.4 288 90 23.5 0.46 11 2.71 11.2 283 88 115ºF 26.92 0.43 9 2.89 12.0 306 98 26.5 0.41 9 2.87 11.9 304 97 25.2 0.39 10 2.83 11.7 298 95 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 26.99 0.81 17 2.39 9.3 196 74 26.6 0.78 18 2.38 9.2 195 73 25.3 0.74 19 2.34 9.0 191 72 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 25.8 26.7 29.3 25.2 26.1 28.6 0.80 0.67 0.46 0.82 0.69 0.48 16 14 11 16 14 11 2.32 2.37 2.45 2.44 2.49 2.57 9.0 9.2 9.5 9.6 9.8 10.2 181 194 205 206 221 234 69 73 80 72 77 84 25.4 26.3 28.8 24.8 25.7 28.1 0.76 0.64 0.44 0.79 0.66 0.46 17 15 11 17 15 11 2.31 2.36 2.43 2.43 2.48 2.56 8.9 9.1 9.4 9.5 9.8 10.1 179 193 204 204 220 232 68 72 79 72 76 83 24.1 25.0 27.4 23.5 24.4 26.7 0.73 0.61 0.42 0.75 0.63 0.44 18 15 12 18 15 12 2.27 2.32 2.40 2.39 2.44 2.52 8.7 9.0 9.3 9.3 9.6 9.9 176 189 200 200 215 227 67 71 78 70 75 81 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130301A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 27.99 0.94 21 2.07 7.8 144 64 27.6 0.90 22 2.06 7.7 143 63 26.2 0.86 22 2.03 7.6 140 62 28.47 0.98 22 2.09 7.8 146 64 28.1 0.94 23 2.07 7.8 145 64 26.7 0.90 24 2.04 7.6 142 63 Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR 29.03 0.95 22 2.13 8.0 157 68 28.6 0.91 23 2.12 8.0 156 68 27.2 0.87 23 2.08 7.8 153 67 63 28.60 0.88 20 2.11 8.0 155 68 28.2 0.84 21 2.10 7.9 154 67 26.8 0.80 21 2.07 7.8 151 66 30.40 0.85 20 2.19 8.3 166 75 29.9 0.82 21 2.18 8.2 165 74 28.5 0.78 22 2.15 8.1 161 73 67 30.55 0.71 17 2.18 8.2 164 74 30.1 0.68 18 2.17 8.2 163 74 28.6 0.65 19 2.13 8.0 160 72 32.43 0.69 18 2.26 8.6 173 80 32.0 0.66 19 2.25 8.5 172 79 30.4 0.64 19 2.22 8.4 168 77 71 32.66 0.53 14 2.25 8.5 171 79 32.2 0.51 14 2.23 8.5 170 78 30.6 0.49 15 2.20 8.3 166 77 27.81 1.00 22 2.24 8.5 164 68 27.4 0.97 23 2.23 8.4 162 68 26.0 0.93 24 2.19 8.3 159 66 59 27.33 0.97 21 2.22 8.4 162 67 26.9 0.93 22 2.21 8.3 161 67 25.6 0.89 23 2.18 8.2 158 66 28.35 0.98 22 2.29 8.7 176 72 27.9 0.94 23 2.28 8.6 175 72 26.5 0.90 24 2.24 8.5 171 70 63 27.93 0.91 20 2.27 8.6 174 72 27.5 0.87 21 2.26 8.5 173 71 26.1 0.83 22 2.22 8.4 170 70 29.69 0.89 21 2.36 9.0 186 79 29.3 0.85 22 2.35 8.9 185 78 27.8 0.81 22 2.31 8.8 181 77 67 29.84 0.74 17 2.34 8.9 184 78 29.4 0.71 18 2.33 8.8 183 78 27.9 0.68 19 2.29 8.7 179 76 75ºF 31.68 0.72 18 2.44 9.3 194 84 31.2 0.69 19 2.42 9.3 193 84 29.6 0.66 19 2.38 9.1 189 82 71 31.90 0.55 14 2.42 9.2 192 83 31.4 0.53 15 2.40 9.2 191 83 29.9 0.51 15 2.37 9.0 187 81 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 27.15 1.00 21 2.38 9.2 186 71 26.7 1.00 23 2.37 9.2 185 70 25.4 0.96 24 2.33 9.0 181 69 27.68 1.00 22 2.43 9.4 200 75 27.3 0.96 23 2.42 9.4 199 75 25.9 0.92 24 2.38 9.2 195 73 30.92 0.74 18 2.59 10.1 221 87 30.5 0.71 19 2.58 10.1 219 87 28.9 0.68 19 2.53 9.9 215 85 26.49 1.00 21 2.50 9.9 212 74 26.1 1.00 23 2.49 9.8 210 74 24.8 0.99 24 2.45 9.6 206 72 27.00 1.00 21 2.56 10.1 228 79 26.6 0.99 23 2.54 10.0 226 78 25.3 0.95 24 2.50 9.9 222 77 28.28 0.94 21 2.64 10.4 241 86 27.9 0.90 22 2.62 10.4 239 86 26.5 0.86 23 2.58 10.2 234 84 30.17 0.76 18 2.73 10.8 251 92 29.7 0.73 19 2.71 10.8 249 91 28.2 0.70 20 2.66 10.6 244 89 25.16 1.00 20 2.61 10.5 238 78 24.8 1.00 22 2.59 10.4 237 77 23.6 1.00 23 2.55 10.2 232 76 59 24.73 1.00 19 2.58 10.4 236 77 24.4 1.00 21 2.57 10.3 234 76 23.1 0.98 22 2.53 10.1 230 75 25.65 1.00 20 2.66 10.8 257 83 25.3 1.00 22 2.65 10.7 255 82 24.0 0.99 24 2.60 10.5 250 81 63 25.27 1.00 20 2.64 10.7 254 82 24.9 0.96 21 2.63 10.6 252 81 23.7 0.92 21 2.58 10.4 247 80 26.86 0.97 20 2.75 11.1 271 90 26.5 0.93 22 2.73 11.1 269 90 25.1 0.89 22 2.69 10.8 264 88 67 27.00 0.81 17 2.73 11.0 268 89 26.6 0.78 18 2.71 11.0 266 89 25.3 0.75 19 2.67 10.7 261 87 105ºF 28.66 0.79 18 2.84 11.6 283 96 28.2 0.76 19 2.82 11.5 281 96 26.8 0.72 19 2.78 11.3 275 94 71 28.86 0.61 14 2.82 11.4 280 95 28.4 0.58 14 2.80 11.4 278 95 27.0 0.56 15 2.75 11.2 272 93 23.31 1.00 18 2.70 11.1 263 80 23.0 1.00 20 2.68 11.1 262 80 21.8 1.00 22 2.64 10.9 256 78 59 22.91 1.00 18 2.67 11.0 261 80 22.6 1.00 20 2.66 11.0 259 79 21.4 0.99 21 2.61 10.8 254 78 23.76 1.00 19 2.75 11.4 283 86 23.4 1.00 20 2.74 11.3 281 85 22.2 1.00 22 2.69 11.1 276 83 63 23.41 1.00 18 2.73 11.3 281 85 23.1 0.96 19 2.72 11.2 279 84 21.9 0.92 20 2.67 11.0 273 82 24.88 0.98 19 2.84 11.8 299 93 24.5 0.94 20 2.83 11.7 297 93 23.3 0.90 21 2.78 11.5 291 91 67 25.01 0.82 16 2.82 11.7 296 93 24.6 0.78 17 2.80 11.6 294 92 23.4 0.75 17 2.76 11.4 288 90 115ºF 26.55 0.80 17 2.94 12.3 312 100 26.2 0.76 17 2.92 12.2 310 99 24.8 0.73 18 2.87 11.9 304 97 71 26.74 0.61 13 2.92 12.1 309 99 26.3 0.59 14 2.90 12.1 307 98 25.0 0.56 14 2.85 11.8 301 96 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 28.98 0.91 21 2.51 9.8 211 82 28.6 0.87 22 2.49 9.7 210 82 27.1 0.83 22 2.45 9.5 206 80 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 26.68 27.27 29.13 31.14 26.03 26.60 28.42 30.38 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.59 21 20 17 14 20 20 17 14 2.36 2.41 2.49 2.57 2.48 2.54 2.62 2.70 9.1 9.4 9.7 10.0 9.8 10.0 10.3 10.7 184 198 209 218 210 226 238 249 70 74 81 87 74 78 85 91 26.3 26.9 28.7 30.7 25.6 26.2 28.0 29.9 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 22 21 18 15 22 21 18 15 2.35 2.40 2.47 2.55 2.47 2.52 2.60 2.69 9.1 9.3 9.6 10.0 9.7 9.9 10.3 10.7 183 197 208 217 208 224 237 247 69 74 81 86 73 78 85 90 25.0 25.5 27.3 29.1 24.4 24.9 26.6 28.4 0.91 0.86 0.70 0.52 0.94 0.88 0.72 0.54 23 22 19 15 23 22 19 15 2.31 2.36 2.43 2.51 2.43 2.48 2.56 2.64 8.9 9.1 9.4 9.8 9.5 9.8 10.1 10.5 179 193 204 212 204 220 232 242 68 72 79 84 72 76 83 88 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130301A*** (CONT.) 15 16 www.goodmanmfg.com 59 26.5 0.78 16 1.81 8.0 147 61 26.1 0.74 17 1.80 7.9 146 61 24.8 0.71 18 1.77 7.8 143 60 26.91 0.88 19 1.83 8.0 149 62 26.5 0.85 20 1.82 8.0 148 62 25.2 0.81 20 1.79 7.9 145 60 Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR 27.70 0.79 17 1.87 8.2 160 66 27.3 0.76 18 1.86 8.2 159 66 25.9 0.72 19 1.83 8.0 156 64 63 27.4 0.65 14 1.85 8.1 159 65 27.0 0.62 15 1.84 8.1 158 65 25.7 0.60 15 1.81 8.0 154 64 29.99 0.60 14 1.93 8.5 169 72 29.5 0.57 15 1.92 8.4 168 72 28.1 0.55 15 1.89 8.3 165 70 67 30.0 0.45 11 1.91 8.4 168 71 29.6 0.43 11 1.90 8.3 166 71 28.1 0.41 12 1.87 8.2 163 69 32.18 0.38 10 1.99 8.8 177 77 31.7 0.37 10 1.98 8.7 175 76 30.1 0.35 11 1.95 8.6 172 75 71 26.28 0.92 19 1.97 8.6 167 66 25.9 0.88 20 1.96 8.6 166 65 24.6 0.84 20 1.93 8.4 163 64 59 25.8 0.81 16 1.96 8.6 165 65 25.5 0.77 17 1.95 8.5 164 64 24.2 0.74 18 1.91 8.4 161 63 27.06 0.82 17 2.02 8.8 180 70 26.7 0.78 18 2.01 8.8 179 69 25.3 0.75 19 1.97 8.6 175 68 63 26.8 0.67 14 2.00 8.8 178 69 26.4 0.64 15 1.99 8.7 177 69 25.1 0.62 15 1.96 8.6 173 67 29.29 0.62 14 2.09 9.1 190 76 28.9 0.59 15 2.07 9.1 189 76 27.4 0.57 15 2.04 8.9 185 74 67 29.3 0.47 11 2.07 9.0 188 75 28.9 0.45 11 2.06 9.0 187 75 27.5 0.43 12 2.02 8.8 183 73 75ºF 31.43 0.40 10 2.16 9.4 198 81 31.0 0.38 10 2.15 9.4 197 81 29.4 0.37 11 2.11 9.2 193 79 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 25.66 0.94 19 2.11 9.3 190 68 25.3 0.90 20 2.09 9.3 189 68 24.0 0.86 21 2.06 9.1 185 66 28.59 0.64 14 2.23 9.8 216 79 28.2 0.61 15 2.21 9.8 215 79 26.8 0.58 15 2.17 9.6 210 77 30.69 0.41 10 2.30 10.2 225 84 30.2 0.39 10 2.29 10.1 224 84 28.7 0.38 11 2.25 10.0 219 82 25.03 0.97 19 2.22 9.9 216 72 24.7 0.93 20 2.21 9.9 215 71 23.4 0.89 21 2.17 9.7 211 70 25.77 0.87 18 2.27 10.2 233 76 25.4 0.83 18 2.26 10.1 231 76 24.12 0.80 19 2.22 9.9 227 74 27.89 0.66 14 2.35 10.5 246 83 27.5 0.63 15 2.34 10.4 244 83 26.1 0.60 16 2.29 10.2 239 81 29.94 0.42 10 2.43 10.9 257 89 29.5 0.40 10 2.42 10.8 255 88 28.0 0.39 11 2.37 10.6 250 86 71 23.78 1.00 19 2.32 10.5 244 75 23.4 0.96 20 2.30 10.5 242 74 22.3 0.92 20 2.26 10.3 237 73 59 23.4 0.89 16 2.30 10.5 241 74 23.0 0.85 17 2.28 10.4 239 74 21.9 0.81 18 2.24 10.2 235 72 24.48 0.90 17 2.37 10.8 262 80 24.1 0.86 18 2.36 10.7 260 79 22.9 0.83 19 2.32 10.5 255 78 63 24.2 0.74 14 2.35 10.7 259 79 23.9 0.71 15 2.34 10.6 258 78 22.7 0.68 15 2.30 10.4 253 77 26.50 0.68 14 2.45 11.1 277 87 26.1 0.65 15 2.44 11.1 275 86 24.8 0.62 15 2.40 10.9 269 85 67 26.6 0.51 11 2.43 11.0 274 86 26.2 0.49 11 2.42 11.0 272 86 24.9 0.47 12 2.38 10.8 267 84 105ºF 28.44 0.44 10 2.54 11.5 289 93 28.0 0.42 10 2.52 11.5 287 92 26.6 0.40 11 2.48 11.3 281 90 71 22.03 1.00 17 2.40 11.1 269 78 21.7 0.97 18 2.39 11.1 267 77 20.6 0.93 19 2.35 10.9 262 75 59 21.7 0.89 15 2.38 11.0 266 77 21.3 0.85 16 2.37 11.0 265 76 20.3 0.82 16 2.33 10.8 259 75 22.68 0.91 16 2.46 11.4 290 83 22.3 0.87 17 2.44 11.3 288 82 21.2 0.83 18 2.40 11.1 282 80 63 22.4 0.75 13 2.44 11.3 287 82 22.1 0.71 14 2.42 11.2 285 81 21.0 0.68 14 2.38 11.0 279 80 24.55 0.69 13 2.54 11.8 306 90 24.2 0.66 14 2.53 11.7 304 89 23.0 0.63 14 2.48 11.5 298 88 67 24.6 0.52 10 2.52 11.7 303 89 24.2 0.49 10 2.51 11.6 301 89 23.0 0.47 11 2.46 11.4 295 87 115ºF 26.35 0.44 9 2.63 12.2 319 96 26.0 0.42 10 2.62 12.1 317 95 24.7 0.41 10 2.57 11.9 310 93 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 26.42 0.84 17 2.15 9.6 205 72 26.0 0.80 18 2.14 9.5 203 72 24.7 0.77 19 2.10 9.3 199 71 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 25.2 26.1 28.6 24.6 25.5 28.0 0.83 0.69 0.48 0.85 0.71 0.49 16 14 11 16 14 11 2.09 2.13 2.21 2.20 2.25 2.33 9.3 9.5 9.8 9.9 10.1 10.4 188 202 214 214 231 244 67 72 78 71 75 82 24.9 25.8 28.2 24.2 25.1 27.5 0.79 0.66 0.46 0.82 0.68 0.47 17 15 11 17 15 11 2.07 2.12 2.19 2.19 2.24 2.31 9.2 9.4 9.7 9.8 10.0 10.3 187 201 212 213 229 242 67 71 78 70 75 82 23.6 24.5 26.8 23.0 23.9 26.2 0.76 0.63 0.44 0.78 0.65 0.45 18 15 12 18 15 12 2.04 2.09 2.16 2.15 2.20 2.27 9.0 9.3 9.5 9.6 9.8 10.2 183 197 208 209 224 237 66 70 76 69 73 80 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130311A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 27.39 0.97 21 1.84 8.1 150 63 27.0 0.93 22 1.83 8.1 149 62 25.6 0.89 23 1.80 7.9 146 61 27.86 1.00 22 1.86 8.2 152 63 27.5 0.97 23 1.85 8.1 151 63 26.1 0.93 24 1.82 8.0 148 62 Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR 28.40 0.98 22 1.90 8.4 164 67 28.0 0.94 23 1.89 8.3 162 67 26.6 0.90 24 1.86 8.2 159 66 63 27.98 0.91 20 1.88 8.3 162 67 27.6 0.87 21 1.87 8.2 161 66 26.2 0.83 22 1.84 8.1 158 65 29.75 0.88 21 1.96 8.6 173 74 29.3 0.85 22 1.95 8.6 171 73 27.8 0.81 22 1.92 8.4 168 72 67 29.90 0.74 17 1.95 8.5 171 73 29.5 0.71 18 1.93 8.5 170 72 28.0 0.68 19 1.90 8.3 166 71 31.74 0.72 18 2.03 8.9 180 78 31.3 0.69 19 2.02 8.9 179 78 29.7 0.66 19 1.98 8.7 175 76 71 31.96 0.55 14 2.01 8.8 178 78 31.5 0.53 15 2.00 8.8 177 77 29.9 0.51 15 1.97 8.6 174 75 27.22 1.00 21 2.01 8.8 171 67 26.8 1.00 23 2.00 8.7 169 66 25.5 0.97 24 1.96 8.6 166 65 59 26.75 1.00 21 1.99 8.7 169 66 26.4 0.96 22 1.98 8.7 168 66 25.0 0.92 23 1.95 8.5 164 64 27.74 1.00 22 2.05 9.0 183 71 27.3 0.97 23 2.04 8.9 182 71 26.0 0.93 24 2.01 8.8 179 69 63 27.33 0.94 20 2.04 8.9 182 70 26.9 0.90 21 2.02 8.9 180 70 25.6 0.86 22 1.99 8.7 177 69 29.06 0.92 21 2.12 9.3 194 78 28.6 0.88 22 2.11 9.2 192 77 27.2 0.84 23 2.07 9.1 189 76 67 29.20 0.77 18 2.11 9.2 192 77 28.8 0.73 18 2.09 9.1 191 76 27.3 0.70 19 2.06 9.0 187 75 75ºF 31.00 0.74 18 2.20 9.6 202 83 30.5 0.71 19 2.18 9.5 201 82 29.0 0.68 20 2.15 9.4 197 80 71 31.22 0.57 14 2.18 9.5 200 82 30.8 0.55 15 2.16 9.5 199 81 29.2 0.53 15 2.13 9.3 195 80 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 26.57 1.00 21 2.14 9.5 194 70 26.2 1.00 23 2.13 9.4 193 69 24.9 0.99 24 2.09 9.3 189 68 27.08 1.00 21 2.19 9.7 209 74 26.7 1.00 23 2.18 9.7 207 73 25.3 0.96 24 2.14 9.5 203 72 30.26 0.76 18 2.34 10.4 230 86 29.8 0.73 19 2.33 10.3 228 85 28.3 0.70 20 2.29 10.1 224 84 25.92 1.00 20 2.26 10.1 221 73 25.5 1.00 22 2.25 10.1 219 72 24.3 1.00 24 2.21 9.9 215 71 26.42 1.00 21 2.31 10.3 238 78 26.0 1.00 23 2.30 10.3 236 77 24.7 0.99 24 2.26 10.1 231 76 27.67 0.97 21 2.39 10.7 251 85 27.3 0.93 22 2.38 10.6 249 84 25.9 0.89 23 2.33 10.4 244 83 29.52 0.79 18 2.47 11.1 262 90 29.1 0.75 19 2.46 11.0 260 90 27.6 0.72 20 2.42 10.8 255 88 24.62 1.00 19 2.36 10.7 248 77 24.3 1.00 21 2.34 10.7 247 76 23.0 1.00 23 2.30 10.5 242 74 59 24.20 1.00 19 2.34 10.6 246 76 23.8 1.00 21 2.32 10.6 244 75 22.7 1.01 23 2.28 10.4 239 74 25.10 1.00 20 2.41 11.0 267 81 24.7 1.00 22 2.40 10.9 266 81 23.5 1.00 23 2.36 10.7 260 79 63 24.73 1.00 19 2.39 10.9 265 81 24.4 0.99 21 2.38 10.8 263 80 23.1 0.95 22 2.34 10.6 258 78 26.29 1.00 21 2.50 11.3 282 89 25.9 0.96 22 2.48 11.3 280 88 24.6 0.92 23 2.44 11.1 275 86 67 26.42 0.84 17 2.48 11.2 280 88 26.0 0.81 18 2.46 11.2 278 87 24.7 0.77 19 2.42 11.0 272 86 105ºF 28.05 0.82 18 2.59 11.7 295 95 27.6 0.78 19 2.57 11.7 292 94 26.2 0.75 20 2.52 11.5 287 92 71 28.24 0.63 14 2.56 11.6 292 94 27.8 0.60 15 2.55 11.6 290 93 26.4 0.58 15 2.50 11.4 284 91 22.81 1.00 18 2.45 11.3 275 79 22.5 1.00 20 2.43 11.3 273 79 21.3 1.00 21 2.39 11.1 267 77 59 22.42 1.00 18 2.42 11.2 272 78 22.1 1.00 19 2.41 11.2 270 78 21.0 1.02 21 2.37 11.0 265 76 23.25 1.00 18 2.50 11.6 295 84 22.9 1.00 20 2.49 11.5 293 84 21.8 1.00 22 2.44 11.3 288 82 63 22.91 1.00 18 2.48 11.5 293 83 22.6 1.00 20 2.47 11.4 290 83 21.4 0.96 20 2.42 11.2 285 81 24.35 1.00 19 2.59 12.0 312 92 24.0 0.97 20 2.57 11.9 310 91 22.8 0.93 21 2.53 11.7 304 89 67 24.47 0.85 16 2.57 11.9 309 91 24.1 0.81 17 2.55 11.8 307 90 22.9 0.78 18 2.51 11.6 301 89 115ºF 25.98 0.82 17 2.68 12.4 325 98 25.6 0.79 18 2.66 12.3 323 97 24.3 0.76 18 2.62 12.1 317 95 71 26.16 0.63 13 2.66 12.3 322 97 25.8 0.61 14 2.64 12.2 320 96 24.5 0.58 14 2.59 12.0 314 94 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 28.36 0.94 21 2.27 10.0 220 81 27.9 0.90 22 2.25 10.0 219 80 26.5 0.86 23 2.21 9.8 214 79 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 26.11 26.68 28.51 30.47 25.47 26.03 27.81 29.73 1.00 0.97 0.79 0.59 1.00 1.00 0.81 0.61 20 20 18 14 20 20 18 14 2.12 2.17 2.25 2.32 2.24 2.29 2.37 2.45 9.4 9.6 9.9 10.3 10.0 10.3 10.6 11.0 192 207 218 228 219 235 249 259 69 73 80 85 72 77 84 89 25.7 26.3 28.1 30.0 25.1 25.6 27.4 29.3 0.99 0.92 0.75 0.56 1.00 0.95 0.78 0.58 22 21 19 15 22 21 19 15 2.11 2.16 2.23 2.31 2.23 2.28 2.36 2.44 9.4 9.6 9.9 10.2 10.0 10.2 10.5 10.9 191 205 217 226 217 234 247 257 68 73 79 85 72 76 83 89 24.4 25.0 26.7 28.5 23.8 24.4 26.0 27.8 0.94 0.89 0.72 0.54 0.98 0.91 0.74 0.56 23 22 19 15 23 22 19 15 2.07 2.12 2.19 2.27 2.19 2.24 2.31 2.40 9.2 9.4 9.7 10.0 9.8 10.0 10.3 10.7 187 201 212 221 213 229 242 252 67 71 78 83 70 75 82 87 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130311A*** (CONT.) 17 18 www.goodmanmfg.com 59 33.8 0.76 17 2.47 9.2 143 65 33.3 0.73 17 2.46 9.1 142 65 31.6 0.69 18 2.42 9.0 139 63 34.37 0.86 19 2.49 9.3 145 66 33.9 0.82 20 2.48 9.2 144 65 32.2 0.79 21 2.44 9.0 141 64 Airflow MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR 35.39 0.77 18 2.54 9.5 156 70 34.9 0.74 19 2.53 9.4 155 70 33.1 0.71 19 2.49 9.2 151 68 63 35.0 0.63 14 2.52 9.4 154 69 34.5 0.61 15 2.51 9.3 153 69 32.8 0.58 16 2.47 9.2 150 67 38.30 0.58 14 2.62 9.8 164 76 37.7 0.56 15 2.60 9.7 163 76 35.9 0.53 16 2.56 9.5 160 74 67 38.4 0.44 11 2.60 9.7 163 76 37.8 0.42 11 2.58 9.6 162 75 35.9 0.40 12 2.54 9.5 158 74 41.11 0.37 10 2.69 10.1 171 81 40.5 0.36 10 2.68 10.1 170 81 38.5 0.34 11 2.64 9.9 167 79 71 33.57 0.89 19 2.67 10.0 162 70 33.1 0.85 20 2.66 9.9 161 69 31.4 0.82 21 2.62 9.7 158 68 59 33.0 0.79 17 2.65 9.9 161 69 32.5 0.75 18 2.64 9.8 159 68 30.9 0.72 18 2.60 9.7 156 67 34.56 0.80 18 2.72 10.2 175 74 34.1 0.76 19 2.71 10.2 173 73 32.4 0.73 19 2.67 10.0 170 72 63 34.2 0.66 14 2.70 10.1 173 73 33.7 0.63 15 2.69 10.1 172 73 32.0 0.60 16 2.65 9.9 168 71 37.41 0.60 15 2.81 10.5 184 81 36.9 0.58 15 2.79 10.5 183 80 35.0 0.55 16 2.75 10.3 179 79 67 37.5 0.45 11 2.79 10.5 183 80 36.9 0.43 12 2.77 10.4 181 79 35.1 0.42 12 2.73 10.2 178 78 75ºF 40.15 0.39 10 2.89 10.9 192 86 39.6 0.37 11 2.88 10.9 191 85 37.6 0.36 11 2.83 10.7 187 84 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 32.77 0.91 19 2.83 10.8 185 72 32.3 0.88 20 2.81 10.8 183 72 30.7 0.84 21 2.77 10.6 180 70 36.52 0.62 15 2.98 11.4 210 84 36.0 0.59 15 2.96 11.4 208 83 34.2 0.57 16 2.91 11.2 204 82 39.20 0.40 10 3.07 11.9 219 89 38.6 0.38 11 3.05 11.8 217 89 36.7 0.37 11 3.00 11.6 213 87 31.97 0.94 19 2.97 11.6 210 76 31.5 0.90 21 2.95 11.5 209 75 29.9 0.87 21 2.91 11.3 205 74 32.92 0.84 18 3.03 11.8 226 81 32.4 0.81 19 3.01 11.8 225 80 30.81 0.77 20 2.97 11.5 220 79 35.63 0.64 15 3.13 12.2 239 88 35.1 0.61 15 3.11 12.1 237 88 33.3 0.59 16 3.06 11.9 232 86 38.24 0.41 10 3.23 12.7 249 94 37.7 0.39 11 3.21 12.6 247 93 35.8 0.38 11 3.16 12.4 242 91 71 30.37 0.98 19 3.09 12.3 236 80 29.9 0.94 20 3.07 12.2 235 79 28.4 0.90 21 3.02 12.0 230 77 59 29.9 0.86 17 3.06 12.2 234 79 29.4 0.83 18 3.05 12.1 232 78 28.0 0.79 18 3.00 11.9 228 77 31.27 0.88 18 3.15 12.6 254 85 30.8 0.84 19 3.14 12.5 253 84 29.3 0.80 19 3.09 12.3 248 82 63 31.0 0.72 14 3.13 12.5 252 84 30.5 0.69 15 3.11 12.4 250 83 29.0 0.66 16 3.06 12.2 245 82 33.85 0.66 14 3.25 13.0 269 92 33.3 0.64 15 3.23 12.9 267 92 31.7 0.61 16 3.18 12.7 261 90 67 33.9 0.50 11 3.23 12.9 266 91 33.4 0.48 12 3.21 12.8 264 91 31.7 0.46 12 3.16 12.6 259 89 105ºF 36.33 0.43 10 3.36 13.5 280 98 35.8 0.41 11 3.34 13.4 278 98 34.0 0.39 11 3.28 13.2 273 96 71 28.14 0.99 18 3.19 13.0 261 82 27.7 0.95 19 3.17 12.9 259 82 26.3 0.91 20 3.12 12.7 254 80 59 27.7 0.87 16 3.16 12.9 259 81 27.3 0.83 16 3.15 12.8 257 81 25.9 0.80 17 3.10 12.6 252 79 28.97 0.88 17 3.26 13.3 281 88 28.5 0.85 17 3.24 13.2 279 87 27.1 0.81 18 3.19 13.0 274 85 63 28.7 0.73 13 3.23 13.2 278 87 28.3 0.70 14 3.21 13.1 276 86 26.8 0.67 15 3.16 12.9 271 84 31.36 0.67 14 3.36 13.8 297 96 30.9 0.64 14 3.34 13.7 295 95 29.3 0.61 15 3.29 13.4 289 93 67 31.4 0.50 10 3.33 13.6 294 95 31.0 0.48 11 3.32 13.6 292 94 29.4 0.46 11 3.26 13.3 286 92 115ºF 33.65 0.43 9 3.47 14.3 310 102 33.2 0.41 10 3.45 14.2 307 101 31.5 0.39 10 3.39 13.9 301 99 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 33.74 0.82 18 2.89 11.1 199 77 33.2 0.78 19 2.87 11.0 197 76 31.6 0.75 19 2.83 10.8 193 75 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 32.2 33.4 36.6 31.4 32.6 35.7 0.80 0.67 0.47 0.83 0.69 0.48 17 14 11 17 15 11 2.81 2.86 2.95 2.95 3.01 3.10 10.7 11.0 11.3 11.5 11.7 12.1 183 197 208 208 224 236 72 76 83 75 80 87 31.7 32.9 36.1 31.0 32.1 35.2 0.77 0.64 0.45 0.80 0.66 0.46 18 15 12 18 15 12 2.79 2.85 2.94 2.93 2.99 3.08 10.7 10.9 11.3 11.4 11.7 12.0 181 195 206 207 222 235 71 76 82 75 79 87 30.2 31.3 34.3 29.4 30.5 33.4 0.74 0.62 0.43 0.76 0.64 0.44 18 16 12 18 16 12 2.75 2.81 2.89 2.88 2.94 3.03 10.5 10.7 11.1 11.2 11.4 11.8 178 191 202 202 218 230 70 74 81 73 78 85 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130361A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 34.98 0.94 21 2.51 9.3 146 66 34.5 0.90 22 2.50 9.3 145 66 32.7 0.87 23 2.46 9.1 142 65 35.59 0.99 23 2.53 9.4 148 67 35.1 0.95 24 2.52 9.4 146 67 33.3 0.91 25 2.48 9.2 144 65 Airflow MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR 36.28 0.96 22 2.58 9.6 159 71 35.7 0.91 24 2.57 9.6 158 71 34.0 0.88 24 2.53 9.4 154 69 63 35.75 0.89 20 2.56 9.6 157 71 35.2 0.85 22 2.55 9.5 156 70 33.5 0.81 22 2.51 9.3 153 69 38.00 0.86 21 2.66 9.9 168 78 37.4 0.83 22 2.64 9.9 166 77 35.6 0.79 23 2.60 9.7 163 76 67 38.19 0.72 18 2.64 9.9 166 77 37.6 0.69 19 2.62 9.8 165 77 35.7 0.66 19 2.58 9.6 162 75 40.54 0.70 18 2.74 10.3 175 83 39.9 0.67 19 2.72 10.2 174 82 37.9 0.64 20 2.68 10.1 170 81 71 40.82 0.54 14 2.72 10.2 173 82 40.2 0.52 15 2.70 10.2 172 82 38.2 0.49 15 2.66 10.0 168 80 34.76 1.00 22 2.71 10.2 166 71 34.3 0.98 24 2.70 10.1 164 70 32.5 0.94 25 2.66 9.9 161 69 59 34.17 0.98 22 2.69 10.1 164 70 33.7 0.94 23 2.68 10.0 163 70 32.0 0.90 23 2.64 9.8 159 68 35.44 0.99 23 2.77 10.4 178 75 34.9 0.95 24 2.75 10.3 177 75 33.2 0.91 25 2.71 10.2 173 73 63 34.91 0.92 21 2.75 10.3 176 75 34.4 0.88 22 2.73 10.2 175 74 32.7 0.84 22 2.69 10.1 172 73 37.11 0.89 21 2.85 10.7 188 82 36.6 0.86 23 2.84 10.7 187 82 34.7 0.82 23 2.79 10.5 183 80 67 37.30 0.75 18 2.83 10.6 186 82 36.8 0.72 19 2.81 10.6 185 81 34.9 0.69 20 2.77 10.4 181 79 75ºF 39.60 0.72 19 2.94 11.1 196 88 39.0 0.69 20 2.92 11.1 195 87 37.1 0.66 20 2.88 10.9 191 85 71 39.88 0.56 14 2.92 11.0 194 87 39.3 0.53 15 2.90 11.0 193 86 37.3 0.51 16 2.86 10.8 189 85 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 33.94 1.00 22 2.87 11.0 188 74 33.4 1.00 24 2.86 11.0 187 73 31.8 0.96 25 2.81 10.8 183 72 34.59 1.00 22 2.93 11.3 203 78 34.1 0.97 24 2.92 11.2 201 78 32.4 0.93 25 2.87 11.0 197 76 38.65 0.74 19 3.12 12.1 223 91 38.1 0.71 20 3.10 12.0 222 91 36.2 0.68 20 3.05 11.8 217 89 33.11 1.00 21 3.02 11.8 214 77 32.6 1.00 24 3.00 11.7 213 77 31.0 1.00 25 2.95 11.5 209 75 33.75 1.00 22 3.08 12.1 231 82 33.3 1.00 24 3.06 12.0 229 82 31.6 0.96 25 3.01 11.8 225 80 35.35 0.95 22 3.18 12.4 244 90 34.8 0.91 23 3.16 12.4 242 89 33.1 0.87 23 3.11 12.1 237 88 37.71 0.77 19 3.28 12.9 254 96 37.2 0.73 20 3.26 12.8 252 95 35.3 0.70 20 3.21 12.6 247 93 31.45 1.00 20 3.14 12.5 241 81 31.0 1.00 22 3.12 12.4 240 81 29.4 1.00 24 3.07 12.2 235 79 59 30.91 1.00 20 3.11 12.4 239 80 30.5 1.00 22 3.10 12.3 237 80 28.9 0.99 23 3.05 12.1 232 78 32.06 1.00 21 3.20 12.8 260 86 31.6 1.00 23 3.19 12.7 258 86 30.0 1.00 24 3.14 12.5 253 84 63 31.59 1.00 20 3.18 12.7 257 85 31.1 0.97 22 3.16 12.6 255 85 29.6 0.92 22 3.11 12.4 250 83 33.58 0.98 21 3.31 13.2 274 94 33.1 0.94 22 3.29 13.2 272 94 31.4 0.90 23 3.23 12.9 267 92 67 33.75 0.82 18 3.28 13.1 271 93 33.3 0.79 19 3.26 13.0 270 93 31.6 0.75 19 3.21 12.8 264 91 105ºF 35.82 0.80 18 3.41 13.7 286 100 35.3 0.76 19 3.39 13.6 284 100 33.5 0.73 20 3.34 13.4 278 98 71 36.08 0.61 14 3.38 13.6 283 99 35.5 0.59 15 3.37 13.5 281 99 33.8 0.56 16 3.31 13.3 275 97 29.14 1.00 19 3.24 13.2 267 84 28.7 1.00 21 3.22 13.2 265 83 27.3 1.00 22 3.17 12.9 259 82 59 28.64 1.00 18 3.22 13.1 264 83 28.2 1.00 20 3.20 13.0 262 83 26.8 0.99 22 3.15 12.8 257 81 29.70 1.00 19 3.31 13.6 287 89 29.3 1.00 21 3.29 13.5 285 89 27.8 1.00 23 3.24 13.2 279 87 63 29.26 1.00 19 3.28 13.4 284 88 28.8 0.97 20 3.27 13.4 282 88 27.4 0.93 21 3.21 13.1 276 86 31.11 0.99 20 3.42 14.0 303 97 30.6 0.95 21 3.40 13.9 301 97 29.1 0.91 22 3.34 13.7 295 95 67 31.26 0.83 17 3.39 13.9 300 97 30.8 0.79 18 3.37 13.8 298 96 29.3 0.76 18 3.32 13.6 292 94 115ºF 33.19 0.80 17 3.53 14.5 316 104 32.7 0.77 18 3.51 14.5 314 103 31.1 0.74 19 3.45 14.2 307 101 71 33.42 0.62 13 3.50 14.4 313 103 32.9 0.59 14 3.48 14.3 311 102 31.3 0.57 14 3.42 14.1 304 100 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 36.23 0.92 21 3.02 11.7 214 86 35.7 0.88 23 3.01 11.6 212 85 33.9 0.84 23 2.96 11.4 208 83 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 33.35 34.08 36.41 38.93 32.54 33.25 35.53 37.98 1.00 0.94 0.77 0.57 1.00 0.97 0.79 0.59 22 21 18 14 21 21 18 14 2.85 2.91 3.00 3.09 2.99 3.06 3.15 3.25 10.9 11.2 11.6 12.0 11.7 11.9 12.3 12.8 186 201 212 221 212 228 241 252 73 78 85 90 77 82 89 95 32.9 33.6 35.9 38.4 32.1 32.8 35.0 37.4 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 23 22 19 15 23 22 19 15 2.84 2.89 2.98 3.08 2.98 3.04 3.13 3.23 10.9 11.1 11.5 11.9 11.6 11.9 12.3 12.7 185 199 210 219 211 227 240 250 72 77 84 90 76 81 88 94 31.2 31.9 34.1 36.4 30.5 31.1 33.3 35.5 0.92 0.86 0.70 0.53 0.95 0.89 0.73 0.54 23 23 20 16 24 23 20 16 2.79 2.85 2.94 3.03 2.93 2.99 3.08 3.18 10.7 10.9 11.3 11.7 11.4 11.7 12.0 12.5 181 195 206 215 207 222 235 245 71 76 82 88 75 79 87 92 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130361A*** (CONT.) 19 20 www.goodmanmfg.com 59 39.2 0.77 16 2.84 10.6 137 60 38.1 0.73 17 2.82 10.5 136 60 35.1 0.70 17 2.76 10.2 132 58 39.86 0.87 19 2.87 10.7 139 61 38.7 0.83 20 2.84 10.6 137 60 35.7 0.80 20 2.78 10.3 133 58 Airflow MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR 41.04 0.78 17 2.92 10.9 149 65 39.8 0.74 18 2.90 10.8 148 64 36.8 0.72 18 2.84 10.5 143 62 63 40.6 0.64 14 2.90 10.8 148 64 39.4 0.61 15 2.88 10.7 146 63 36.4 0.59 15 2.82 10.4 142 62 44.42 0.59 14 3.01 11.3 157 71 43.1 0.56 15 2.98 11.2 156 70 39.8 0.54 15 2.92 10.9 151 68 67 44.5 0.44 11 2.98 11.2 156 70 43.2 0.42 11 2.96 11.1 154 69 39.9 0.41 11 2.90 10.8 150 67 47.68 0.38 10 3.10 11.7 164 75 46.3 0.36 10 3.07 11.6 163 75 42.7 0.35 10 3.00 11.3 158 72 71 38.93 0.90 19 3.07 11.5 155 64 37.8 0.86 20 3.05 11.4 154 64 34.9 0.83 20 2.98 11.1 149 62 59 38.3 0.79 17 3.05 11.4 154 64 37.2 0.76 17 3.02 11.3 152 63 34.3 0.73 18 2.96 11.0 148 61 40.09 0.81 18 3.13 11.8 167 68 38.9 0.77 18 3.11 11.7 166 68 35.9 0.74 19 3.04 11.4 161 66 63 39.7 0.66 14 3.11 11.7 166 68 38.5 0.63 15 3.08 11.6 164 67 35.6 0.61 15 3.01 11.3 159 65 43.39 0.61 14 3.22 12.2 177 75 42.1 0.58 15 3.20 12.1 175 74 38.9 0.56 15 3.13 11.7 170 72 67 43.5 0.46 11 3.20 12.1 175 74 42.2 0.44 11 3.17 11.9 173 73 39.0 0.42 12 3.10 11.6 168 71 75ºF 46.57 0.39 10 3.32 12.6 184 80 45.2 0.37 10 3.30 12.5 182 79 41.7 0.36 11 3.22 12.2 177 76 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 38.01 0.93 19 3.25 12.5 177 67 36.9 0.88 20 3.22 12.4 175 66 34.1 0.85 20 3.15 12.0 170 64 42.36 0.63 14 3.41 13.2 201 78 41.1 0.60 15 3.39 13.1 199 77 38.0 0.58 15 3.31 12.7 193 75 45.46 0.40 10 3.52 13.7 210 83 44.1 0.38 10 3.49 13.6 208 82 40.7 0.37 11 3.41 13.2 201 79 37.08 0.95 19 3.41 13.4 201 70 36.0 0.91 20 3.38 13.2 199 70 33.2 0.88 20 3.30 12.9 193 67 38.18 0.85 18 3.48 13.7 217 75 37.1 0.81 19 3.45 13.6 215 74 34.21 0.79 19 3.37 13.2 208 72 41.32 0.65 15 3.58 14.1 229 82 40.1 0.62 15 3.56 14.0 227 81 37.0 0.59 15 3.47 13.6 220 78 44.35 0.42 10 3.70 14.7 239 87 43.1 0.40 10 3.67 14.5 236 86 39.7 0.38 11 3.58 14.1 229 83 71 35.23 0.99 19 3.54 14.2 227 74 34.2 0.95 20 3.51 14.1 224 73 31.6 0.91 20 3.43 13.7 218 71 59 34.6 0.87 16 3.51 14.1 224 73 33.6 0.83 17 3.49 13.9 222 72 31.0 0.80 17 3.40 13.6 215 70 36.27 0.89 18 3.62 14.6 244 78 35.2 0.85 18 3.59 14.4 241 78 32.5 0.82 19 3.50 14.0 234 75 63 35.9 0.73 14 3.59 14.4 241 78 34.9 0.69 15 3.56 14.3 239 77 32.2 0.67 15 3.47 13.9 232 74 39.26 0.67 14 3.73 15.0 257 85 38.1 0.64 15 3.70 14.9 255 85 35.2 0.62 15 3.61 14.5 247 82 67 39.3 0.50 11 3.70 14.9 255 85 38.2 0.48 11 3.67 14.8 252 84 35.2 0.46 11 3.58 14.4 245 81 105ºF 42.13 0.43 10 3.85 15.6 269 91 40.9 0.41 10 3.82 15.5 266 90 37.8 0.40 10 3.72 15.0 258 87 71 32.63 1.00 18 3.66 15.1 250 76 31.7 0.95 19 3.63 14.9 248 75 29.2 0.92 19 3.54 14.5 240 73 59 32.1 0.88 15 3.63 14.9 248 75 31.2 0.84 16 3.60 14.8 245 75 28.8 0.81 16 3.51 14.4 238 72 33.60 0.89 16 3.73 15.4 269 81 32.6 0.85 17 3.70 15.3 267 80 30.1 0.82 17 3.62 14.9 259 78 63 33.3 0.73 13 3.70 15.3 267 80 32.3 0.70 14 3.68 15.1 264 79 29.8 0.68 14 3.59 14.7 256 77 36.36 0.68 13 3.85 15.9 285 88 35.3 0.65 14 3.82 15.8 282 88 32.6 0.62 14 3.73 15.4 273 85 67 36.4 0.51 10 3.82 15.8 282 88 35.4 0.49 11 3.79 15.6 279 87 32.7 0.47 11 3.70 15.2 270 84 115ºF 39.03 0.44 9 3.97 16.5 297 94 37.9 0.42 10 3.94 16.4 294 93 35.0 0.40 10 3.85 15.9 285 90 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 39.13 0.83 18 3.31 12.8 190 71 38.0 0.79 18 3.29 12.7 188 70 35.1 0.76 19 3.21 12.3 183 68 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 37.4 38.7 42.4 36.5 37.8 41.4 0.81 0.68 0.47 0.84 0.70 0.49 17 14 11 17 14 11 3.22 3.29 3.39 3.38 3.45 3.56 12.4 12.7 13.1 13.2 13.6 14.0 175 188 199 199 215 227 66 70 77 70 74 81 36.3 37.6 41.2 35.4 36.7 40.2 0.78 0.65 0.45 0.80 0.67 0.46 17 15 11 17 15 11 3.20 3.26 3.36 3.35 3.42 3.53 12.3 12.6 13.0 13.1 13.4 13.9 173 187 197 197 212 224 66 70 76 69 73 80 33.5 34.7 38.0 32.7 33.9 37.1 0.75 0.63 0.43 0.77 0.65 0.45 18 15 12 18 15 12 3.13 3.19 3.28 3.28 3.34 3.45 11.9 12.2 12.6 12.7 13.1 13.5 168 181 191 191 206 218 64 68 74 67 71 78 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130421A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 40.57 0.95 21 2.89 10.7 140 62 39.4 0.91 22 2.87 10.7 139 61 36.4 0.88 22 2.80 10.4 134 59 41.28 1.00 22 2.91 10.8 141 62 40.1 0.95 23 2.89 10.7 140 62 37.0 0.92 24 2.82 10.5 136 60 Airflow MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR 42.08 0.97 22 2.96 11.1 152 66 40.9 0.92 23 2.94 11.0 151 65 37.7 0.89 23 2.88 10.7 146 63 63 41.46 0.90 20 2.94 11.0 151 65 40.2 0.85 21 2.92 10.9 149 65 37.1 0.82 21 2.86 10.6 145 63 44.07 0.87 21 3.05 11.5 161 72 42.8 0.83 22 3.03 11.4 159 71 39.5 0.80 22 2.96 11.1 154 69 67 44.29 0.73 18 3.03 11.4 159 71 43.0 0.70 18 3.01 11.3 157 71 39.7 0.67 19 2.94 11.0 153 69 47.01 0.71 18 3.14 11.9 168 77 45.6 0.67 19 3.12 11.8 166 76 42.1 0.65 19 3.05 11.5 161 74 71 47.35 0.54 14 3.12 11.8 166 76 46.0 0.52 15 3.10 11.7 164 75 42.4 0.50 15 3.03 11.4 159 73 40.32 1.00 22 3.12 11.7 159 66 39.1 0.99 24 3.09 11.6 157 65 36.1 0.95 24 3.02 11.3 152 63 59 39.63 1.00 22 3.09 11.6 157 65 38.5 0.94 22 3.07 11.5 156 64 35.5 0.91 23 3.00 11.2 151 62 41.10 1.00 22 3.18 12.0 171 70 39.9 0.95 23 3.15 11.9 169 69 36.8 0.92 24 3.08 11.6 164 67 63 40.49 0.93 20 3.15 11.9 169 69 39.3 0.89 21 3.13 11.8 167 68 36.3 0.85 22 3.06 11.5 162 66 43.04 0.90 21 3.27 12.4 180 76 41.8 0.86 22 3.25 12.3 178 75 38.6 0.83 22 3.17 11.9 173 73 67 43.26 0.76 18 3.25 12.3 178 75 42.0 0.72 19 3.22 12.2 177 75 38.8 0.69 19 3.15 11.8 171 72 75ºF 45.92 0.73 18 3.37 12.9 188 81 44.6 0.70 19 3.35 12.7 186 80 41.2 0.67 19 3.27 12.4 181 78 71 46.24 0.56 14 3.35 12.7 186 80 44.9 0.54 15 3.32 12.6 184 80 41.4 0.52 15 3.25 12.3 179 77 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 39.36 1.00 21 3.30 12.7 180 68 38.2 1.00 23 3.27 12.6 179 68 35.3 0.98 24 3.20 12.3 173 66 40.12 1.00 22 3.37 13.0 194 73 39.0 0.98 23 3.34 12.9 192 72 36.0 0.94 24 3.26 12.6 186 70 44.83 0.75 18 3.58 14.0 214 84 43.5 0.72 19 3.55 13.8 212 84 40.2 0.69 19 3.47 13.5 205 81 38.40 1.00 21 3.46 13.6 205 72 37.3 1.00 23 3.43 13.5 203 71 34.4 1.00 24 3.35 13.1 197 69 39.14 1.00 21 3.53 13.9 221 76 38.0 1.00 23 3.50 13.8 219 75 35.1 0.97 24 3.42 13.4 212 73 40.99 0.96 21 3.64 14.4 234 83 39.8 0.91 22 3.61 14.3 231 82 36.7 0.88 23 3.53 13.9 224 80 43.73 0.78 18 3.76 14.9 244 89 42.5 0.74 19 3.73 14.8 241 88 39.2 0.71 20 3.64 14.4 234 85 36.48 1.00 20 3.60 14.5 231 75 35.4 1.00 22 3.57 14.3 229 74 32.7 1.00 23 3.49 13.9 222 72 59 35.85 1.00 20 3.57 14.3 229 74 34.8 1.00 21 3.54 14.2 227 74 32.1 1.00 22 3.46 13.8 220 71 37.18 1.00 20 3.67 14.8 249 80 36.1 1.00 22 3.64 14.7 246 79 33.3 1.00 23 3.56 14.3 239 77 63 36.64 1.00 20 3.64 14.7 246 79 35.6 0.97 21 3.62 14.6 244 78 32.8 0.94 22 3.53 14.2 237 76 38.94 0.99 21 3.79 15.3 263 87 37.8 0.95 22 3.76 15.2 260 86 34.9 0.91 22 3.67 14.8 252 84 67 39.14 0.83 18 3.76 15.2 260 86 38.0 0.79 18 3.73 15.0 258 85 35.1 0.76 19 3.64 14.6 250 83 105ºF 41.55 0.81 18 3.91 15.9 274 93 40.3 0.77 19 3.88 15.8 271 92 37.2 0.74 19 3.78 15.3 263 89 71 41.84 0.62 14 3.88 15.8 271 92 40.6 0.59 15 3.85 15.6 269 91 37.5 0.57 15 3.75 15.2 261 88 33.79 1.00 18 3.72 15.3 255 78 32.8 1.00 20 3.69 15.2 253 77 30.3 1.00 21 3.60 14.8 245 75 59 33.21 1.00 18 3.69 15.2 253 77 32.2 1.00 20 3.66 15.1 250 76 29.8 1.01 21 3.57 14.6 243 74 34.44 1.00 19 3.79 15.7 275 83 33.4 1.00 20 3.76 15.6 272 82 30.9 1.00 22 3.67 15.1 264 79 63 33.94 1.00 18 3.76 15.6 272 82 32.9 0.98 20 3.73 15.4 269 81 30.4 0.95 20 3.65 15.0 261 79 36.07 1.00 20 3.91 16.2 290 90 35.0 0.95 20 3.88 16.1 287 89 32.3 0.92 21 3.79 15.6 279 87 67 36.26 0.84 17 3.88 16.1 287 89 35.2 0.80 17 3.85 15.9 285 88 32.5 0.77 18 3.76 15.5 276 86 115ºF 38.49 0.81 17 4.04 16.9 303 96 37.4 0.77 18 4.01 16.7 300 95 34.5 0.75 18 3.91 16.2 291 92 71 38.76 0.63 13 4.01 16.7 300 95 37.6 0.60 14 3.98 16.5 297 94 34.7 0.58 14 3.88 16.1 288 91 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 42.02 0.93 21 3.47 13.5 205 79 40.8 0.88 22 3.44 13.3 203 78 37.7 0.85 22 3.36 13.0 197 76 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 38.68 39.53 42.23 45.14 37.74 38.56 41.20 44.04 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 21 20 18 14 21 21 18 14 3.27 3.34 3.44 3.55 3.43 3.50 3.61 3.73 12.6 12.9 13.3 13.8 13.5 13.8 14.3 14.8 179 192 203 212 203 219 231 241 68 72 78 84 71 75 82 88 37.6 38.4 41.0 43.8 36.6 37.4 40.0 42.8 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 22 21 19 15 22 21 19 15 3.25 3.31 3.42 3.52 3.41 3.48 3.58 3.70 12.5 12.8 13.2 13.7 13.4 13.7 14.1 14.7 177 190 201 210 201 217 229 239 67 71 78 83 70 75 82 87 34.7 35.4 37.8 40.5 33.8 34.6 36.9 39.5 0.93 0.88 0.71 0.53 0.96 0.90 0.74 0.55 23 22 19 15 23 22 19 15 3.17 3.24 3.34 3.44 3.33 3.40 3.50 3.61 12.2 12.4 12.9 13.3 13.0 13.3 13.7 14.3 172 185 195 203 195 210 222 232 65 69 75 80 68 72 79 84 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130421A*** (CONT.) 21 22 www.goodmanmfg.com 59 44.1 0.76 17 3.22 12.1 142 64 42.8 0.72 18 3.20 12.0 141 63 39.5 0.70 18 3.13 11.7 136 61 44.84 0.86 20 3.24 12.2 144 65 43.5 0.82 21 3.22 12.1 142 64 40.2 0.79 21 3.15 11.8 138 62 Airflow MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR 46.17 0.77 18 3.30 12.5 154 69 44.8 0.74 19 3.28 12.4 153 68 41.4 0.71 19 3.21 12.0 148 66 63 45.7 0.63 15 3.28 12.4 153 68 44.4 0.60 15 3.26 12.3 151 67 41.0 0.58 16 3.19 11.9 147 65 49.98 0.58 15 3.40 12.9 163 75 48.5 0.56 16 3.37 12.8 162 74 44.8 0.54 16 3.30 12.4 157 72 67 50.1 0.44 11 3.37 12.8 161 74 48.6 0.42 12 3.35 12.7 160 73 44.9 0.40 12 3.28 12.3 155 71 53.64 0.38 10 3.50 13.4 170 80 52.1 0.36 11 3.47 13.2 168 79 48.1 0.35 11 3.40 12.9 163 77 71 43.80 0.89 20 3.47 13.2 161 68 42.5 0.85 21 3.44 13.0 159 68 39.3 0.82 21 3.37 12.7 155 65 59 43.1 0.79 17 3.44 13.0 159 67 41.8 0.75 18 3.42 12.9 158 67 38.6 0.72 18 3.34 12.6 153 65 45.10 0.80 18 3.54 13.5 173 73 43.8 0.76 19 3.51 13.4 172 72 40.4 0.74 20 3.43 13.0 166 70 63 44.6 0.66 15 3.51 13.4 172 72 43.3 0.63 16 3.48 13.2 170 71 40.0 0.60 16 3.41 12.9 165 69 48.81 0.61 15 3.64 13.9 183 79 47.4 0.58 16 3.61 13.8 181 78 43.7 0.56 16 3.53 13.4 176 76 67 48.9 0.46 11 3.61 13.8 181 78 47.5 0.43 12 3.58 13.7 179 78 43.8 0.42 12 3.50 13.3 174 75 75ºF 52.39 0.39 10 3.75 14.4 191 84 50.9 0.37 11 3.72 14.3 189 83 46.9 0.36 11 3.64 13.9 183 81 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 42.76 0.92 20 3.67 14.3 183 71 41.5 0.87 21 3.64 14.2 181 70 38.3 0.84 21 3.56 13.8 176 68 47.65 0.62 15 3.85 15.1 208 82 46.3 0.59 16 3.82 15.0 206 81 42.7 0.57 16 3.74 14.6 200 79 51.14 0.40 10 3.97 15.7 217 88 49.7 0.38 11 3.94 15.5 215 87 45.8 0.37 11 3.85 15.1 209 84 41.72 0.95 20 3.84 15.3 209 74 40.5 0.90 21 3.81 15.1 207 74 37.4 0.87 21 3.73 14.7 200 71 42.95 0.85 19 3.92 15.6 225 79 41.7 0.81 19 3.89 15.5 222 78 38.49 0.78 20 3.80 15.1 216 76 46.49 0.64 15 4.04 16.2 237 86 45.1 0.61 16 4.01 16.0 235 86 41.7 0.59 16 3.92 15.6 228 83 49.89 0.41 11 4.16 16.8 247 92 48.4 0.39 11 4.13 16.6 245 91 44.7 0.38 11 4.04 16.2 238 88 71 39.63 0.98 20 3.99 16.2 235 78 38.5 0.94 21 3.96 16.1 232 77 35.5 0.90 21 3.87 15.7 225 75 59 39.0 0.86 17 3.96 16.1 232 77 37.8 0.82 18 3.93 16.0 230 76 34.9 0.79 18 3.84 15.5 223 74 40.80 0.88 18 4.07 16.6 253 83 39.6 0.84 19 4.04 16.5 250 82 36.6 0.81 19 3.95 16.0 243 80 63 40.4 0.72 15 4.04 16.5 250 82 39.2 0.69 16 4.01 16.3 248 81 36.2 0.66 16 3.92 15.9 240 79 44.16 0.66 15 4.20 17.2 267 91 42.9 0.63 16 4.17 17.0 264 90 39.6 0.61 16 4.07 16.6 256 87 67 44.3 0.50 11 4.17 17.0 264 90 43.0 0.48 12 4.13 16.9 261 89 39.7 0.46 12 4.04 16.4 254 86 105ºF 47.40 0.43 10 4.33 17.9 278 96 46.0 0.41 11 4.30 17.7 275 96 42.5 0.39 11 4.20 17.2 267 93 71 36.71 0.99 19 4.12 17.2 259 81 35.6 0.94 19 4.09 17.1 257 80 32.9 0.91 20 3.99 16.6 249 77 59 36.1 0.87 16 4.09 17.1 257 80 35.0 0.83 17 4.06 16.9 254 79 32.3 0.80 17 3.96 16.4 247 77 37.80 0.89 17 4.21 17.6 279 86 36.7 0.84 18 4.17 17.5 276 85 33.9 0.81 18 4.08 17.0 268 82 63 37.4 0.73 14 4.17 17.5 276 85 36.3 0.69 14 4.14 17.3 274 84 33.5 0.67 15 4.04 16.8 265 82 40.91 0.67 14 4.34 18.2 295 94 39.7 0.64 15 4.30 18.1 292 93 36.7 0.62 15 4.20 17.6 283 90 67 41.0 0.50 11 4.30 18.1 292 93 39.8 0.48 11 4.27 17.9 289 92 36.7 0.46 11 4.17 17.4 280 89 115ºF 43.91 0.43 10 4.47 18.9 307 100 42.6 0.41 10 4.44 18.7 304 99 39.3 0.40 10 4.33 18.2 295 96 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 44.02 0.82 18 3.74 14.6 197 75 42.7 0.78 19 3.71 14.5 195 75 39.5 0.75 20 3.63 14.1 189 72 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 42.0 43.6 47.7 41.0 42.5 46.6 0.81 0.67 0.47 0.83 0.70 0.48 17 15 11 17 15 11 3.64 3.71 3.82 3.81 3.89 4.01 14.2 14.5 15.0 15.1 15.5 16.0 181 195 206 207 222 235 70 75 81 74 78 86 40.8 42.3 46.4 39.8 41.3 45.2 0.77 0.64 0.45 0.79 0.66 0.46 18 16 12 18 16 12 3.61 3.68 3.79 3.78 3.86 3.98 14.0 14.4 14.8 15.0 15.4 15.9 180 193 204 205 220 232 69 74 81 73 78 85 37.7 39.1 42.8 36.8 38.1 41.7 0.74 0.62 0.43 0.77 0.64 0.44 18 16 12 18 16 12 3.53 3.60 3.71 3.70 3.77 3.89 13.7 14.0 14.4 14.6 14.9 15.4 174 187 198 198 213 225 67 72 78 71 75 82 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130481A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 45.64 0.95 22 3.27 12.3 145 65 44.3 0.90 23 3.24 12.2 144 65 40.9 0.87 23 3.17 11.9 139 63 46.44 0.99 24 3.29 12.4 146 66 45.1 0.95 25 3.27 12.3 145 65 41.6 0.91 25 3.19 12.0 141 63 Airflow MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR 47.34 0.96 23 3.35 12.7 158 70 46.0 0.91 24 3.33 12.6 156 69 42.4 0.88 25 3.26 12.3 151 67 63 46.64 0.89 21 3.33 12.6 156 69 45.3 0.85 22 3.30 12.5 155 69 41.8 0.82 22 3.23 12.1 150 67 49.58 0.86 22 3.45 13.1 166 76 48.1 0.82 23 3.42 13.0 165 76 44.4 0.79 23 3.35 12.6 160 73 67 49.83 0.72 18 3.42 13.0 165 76 48.4 0.69 19 3.40 12.9 163 75 44.7 0.66 19 3.32 12.5 158 73 52.89 0.70 19 3.55 13.6 174 81 51.4 0.67 20 3.52 13.5 172 81 47.4 0.64 20 3.45 13.1 167 78 71 53.26 0.54 15 3.52 13.5 172 81 51.7 0.51 15 3.50 13.4 170 80 47.7 0.50 16 3.42 13.0 165 77 45.36 1.00 23 3.52 13.4 164 70 44.0 0.98 25 3.49 13.3 163 69 40.6 0.95 25 3.42 12.9 158 67 59 44.58 1.00 23 3.49 13.3 163 69 43.3 0.94 23 3.47 13.2 161 68 39.9 0.90 24 3.39 12.8 156 66 46.24 0.99 23 3.59 13.7 177 74 44.9 0.95 24 3.56 13.6 175 73 41.4 0.91 25 3.48 13.2 170 71 63 45.55 0.92 21 3.56 13.6 175 73 44.2 0.88 22 3.54 13.5 173 73 40.8 0.85 23 3.46 13.1 168 70 48.42 0.90 22 3.69 14.2 187 81 47.0 0.85 23 3.67 14.0 185 80 43.4 0.82 23 3.58 13.7 179 78 67 48.67 0.75 19 3.67 14.0 185 80 47.3 0.71 19 3.64 13.9 183 79 43.6 0.69 20 3.56 13.5 178 77 75ºF 51.66 0.73 19 3.81 14.7 195 86 50.2 0.69 20 3.78 14.6 193 85 46.3 0.67 20 3.69 14.2 187 83 71 52.03 0.56 15 3.78 14.6 193 85 50.5 0.53 15 3.75 14.4 191 84 46.6 0.51 16 3.66 14.0 185 82 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 44.28 1.00 23 3.72 14.6 187 72 43.0 1.00 25 3.69 14.4 185 72 39.7 0.97 25 3.61 14.0 180 69 45.14 1.00 23 3.80 14.9 201 77 43.8 0.97 24 3.77 14.8 199 76 40.4 0.94 25 3.68 14.4 193 74 50.43 0.74 19 4.03 16.0 222 89 49.0 0.71 20 4.00 15.8 219 89 45.2 0.68 20 3.91 15.4 213 86 43.20 1.00 22 3.90 15.6 213 76 41.9 1.00 24 3.87 15.4 211 75 38.7 1.00 25 3.78 15.0 204 73 44.03 1.00 22 3.98 15.9 229 81 42.8 1.00 25 3.95 15.8 227 80 39.5 0.97 25 3.86 15.4 220 78 46.12 0.95 22 4.10 16.5 242 88 44.8 0.90 23 4.07 16.3 240 87 41.3 0.87 24 3.98 15.9 232 85 49.20 0.77 19 4.23 17.1 252 94 47.8 0.73 20 4.20 16.9 250 93 44.1 0.71 20 4.10 16.5 242 90 41.04 1.00 21 4.05 16.6 239 80 39.8 1.00 23 4.02 16.4 237 79 36.8 1.00 24 3.93 15.9 230 76 59 40.33 1.00 21 4.02 16.4 237 79 39.2 1.00 23 3.99 16.3 235 78 36.1 0.99 24 3.90 15.8 228 76 41.83 1.00 21 4.14 17.0 258 85 40.6 1.00 23 4.11 16.8 255 84 37.5 1.00 25 4.01 16.3 248 81 63 41.21 1.00 21 4.11 16.8 255 84 40.0 0.96 22 4.07 16.6 253 83 36.9 0.93 23 3.98 16.2 245 81 43.81 0.98 22 4.27 17.5 272 92 42.5 0.94 23 4.23 17.4 269 92 39.3 0.90 23 4.13 16.9 261 89 67 44.03 0.82 18 4.23 17.4 269 92 42.8 0.78 19 4.20 17.2 267 91 39.5 0.76 20 4.10 16.7 259 88 105ºF 46.74 0.80 19 4.40 18.2 284 98 45.4 0.76 20 4.37 18.0 281 97 41.9 0.73 20 4.26 17.5 273 95 71 47.07 0.61 15 4.37 18.0 281 97 45.7 0.59 15 4.33 17.9 278 96 42.2 0.57 16 4.23 17.4 270 94 38.01 1.00 19 4.19 17.5 265 82 36.9 1.00 21 4.15 17.4 262 81 34.1 1.00 22 4.06 16.9 254 79 59 37.36 1.00 19 4.15 17.4 262 81 36.3 1.00 21 4.12 17.2 259 81 33.5 1.00 22 4.03 16.7 252 78 38.75 1.00 20 4.27 18.0 285 88 37.6 1.00 22 4.24 17.8 282 87 34.7 1.00 23 4.14 17.3 273 84 63 38.18 1.00 19 4.24 17.8 282 87 37.1 0.97 21 4.21 17.6 279 86 34.2 0.94 21 4.11 17.1 271 83 40.58 0.99 21 4.41 18.6 301 96 39.4 0.95 21 4.37 18.4 298 95 36.4 0.91 22 4.27 17.9 289 92 67 40.79 0.83 17 4.37 18.4 298 95 39.6 0.79 18 4.34 18.2 295 94 36.6 0.76 18 4.23 17.7 286 91 115ºF 43.30 0.80 18 4.55 19.3 314 102 42.0 0.77 19 4.51 19.1 311 101 38.8 0.74 19 4.40 18.6 301 98 71 43.60 0.62 14 4.51 19.1 311 101 42.3 0.59 14 4.47 18.9 307 100 39.1 0.57 15 4.37 18.4 298 97 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 47.27 0.92 22 3.91 15.4 212 84 45.9 0.88 23 3.88 15.3 210 83 42.4 0.84 23 3.79 14.8 204 81 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 43.52 44.47 47.51 50.79 42.46 43.38 46.35 49.55 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 22 21 19 15 22 22 19 15 3.69 3.77 3.88 4.00 3.87 3.95 4.07 4.20 14.4 14.8 15.3 15.8 15.4 15.8 16.3 16.9 185 199 210 219 211 227 240 250 72 76 83 89 75 80 87 93 42.3 43.2 46.1 49.3 41.2 42.1 40.0 48.1 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.56 23 22 19 16 23 22 19 16 3.67 3.74 3.85 3.97 3.84 3.92 3.58 4.17 14.3 14.6 15.1 15.7 15.3 15.6 14.1 16.8 183 197 208 217 209 225 229 247 71 75 82 88 74 79 82 92 39.0 39.8 42.6 45.5 38.0 38.9 41.5 44.4 0.92 0.87 0.71 0.53 0.95 0.90 0.73 0.54 24 23 20 16 24 23 20 16 3.58 3.66 3.76 3.88 3.75 3.83 3.95 4.07 13.9 14.2 14.7 15.3 14.9 15.2 15.7 16.3 178 191 202 211 202 218 230 240 69 73 80 85 72 77 84 89 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130481A*** (CONT.) 23 24 www.goodmanmfg.com 59 54.4 0.72 18 3.84 13.8 140 59 52.8 0.69 19 3.81 13.7 139 58 48.7 0.67 19 3.73 13.3 135 56 55.31 0.82 21 3.87 13.9 142 59 53.7 0.78 22 3.84 13.8 140 59 49.6 0.76 22 3.76 13.4 136 57 Airflow MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 56.94 0.74 19 3.95 14.2 153 63 55.3 0.70 20 3.92 14.1 151 63 51.0 0.68 20 3.83 13.7 147 61 63 56.4 0.60 15 3.92 14.1 151 63 54.7 0.58 16 3.89 14.0 150 62 50.5 0.56 16 3.80 13.6 145 60 61.64 0.56 16 4.06 14.7 161 69 59.8 0.53 16 4.03 14.6 160 68 55.2 0.51 17 3.94 14.2 155 66 67 61.8 0.42 12 4.03 14.6 159 68 60.0 0.40 12 4.00 14.4 158 68 55.3 0.39 12 3.91 14.0 153 66 66.15 0.36 11 4.18 15.2 168 73 64.2 0.34 11 4.15 15.1 166 73 59.3 0.33 11 4.06 14.7 161 71 71 54.02 0.85 21 4.15 15.0 159 63 52.4 0.81 22 4.12 14.9 158 62 48.4 0.78 22 4.02 14.5 153 60 59 53.1 0.75 18 4.12 14.9 157 62 51.6 0.72 19 4.09 14.8 156 61 47.6 0.69 19 3.99 14.4 151 60 55.62 0.76 19 4.23 15.4 171 67 54.0 0.73 20 4.20 15.2 170 66 49.8 0.70 20 4.10 14.8 164 64 63 55.1 0.63 16 4.20 15.2 169 66 53.5 0.60 16 4.17 15.1 168 65 49.3 0.58 17 4.07 14.7 163 63 60.20 0.58 16 4.36 15.9 181 73 58.4 0.55 16 4.32 15.7 179 72 53.9 0.53 17 4.23 15.3 174 70 67 60.3 0.43 12 4.32 15.7 179 72 58.6 0.41 12 4.29 15.6 177 71 54.1 0.40 13 4.19 15.2 172 69 75ºF 64.61 0.37 11 4.49 16.5 189 78 62.7 0.35 11 4.46 16.3 187 77 57.9 0.34 12 4.35 15.9 181 74 71 - IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 75 70 IDB 65ºF 52.73 0.87 21 4.39 16.3 181 65 51.2 0.83 22 4.36 16.2 179 65 47.3 0.80 22 4.26 15.7 174 63 58.77 0.59 16 4.62 17.3 206 76 57.1 0.56 16 4.58 17.1 204 75 52.7 0.54 17 4.48 16.6 197 73 63.08 0.38 11 4.76 17.9 214 81 61.2 0.36 11 4.73 17.8 212 80 56.5 0.35 12 4.61 17.3 206 77 51.45 0.90 21 4.61 17.4 206 68 50.0 0.86 22 4.57 17.3 204 68 46.1 0.83 22 4.46 16.8 198 66 52.97 0.81 19 4.70 17.9 222 73 51.4 0.77 20 4.67 17.7 220 72 47.47 0.74 21 4.56 17.2 213 70 57.34 0.61 16 4.85 18.5 234 80 55.7 0.58 17 4.81 18.3 232 79 51.4 0.56 17 4.70 17.8 225 76 61.54 0.39 11 5.00 19.2 244 85 59.7 0.37 11 4.96 19.0 242 84 55.1 0.36 12 4.84 18.5 235 81 71 48.88 0.94 21 4.79 18.6 232 72 47.5 0.89 22 4.75 18.4 230 71 43.8 0.86 22 4.64 17.9 223 69 59 48.1 0.82 18 4.75 18.4 229 71 46.7 0.79 19 4.72 18.2 227 70 43.1 0.76 19 4.60 17.7 220 68 50.32 0.84 19 4.89 19.0 249 76 48.9 0.80 20 4.85 18.8 247 76 45.1 0.77 20 4.74 18.3 240 73 63 49.8 0.69 16 4.85 18.8 247 76 48.4 0.66 16 4.81 18.7 245 75 44.6 0.63 16 4.70 18.2 237 73 54.47 0.63 16 5.04 19.7 263 83 52.9 0.60 16 5.00 19.5 261 82 48.8 0.58 17 4.88 18.9 253 80 67 54.6 0.48 12 5.00 19.5 261 82 53.0 0.45 12 4.96 19.3 258 82 48.9 0.44 13 4.85 18.8 250 79 105ºF 58.46 0.41 11 5.21 20.4 275 89 56.8 0.39 11 5.16 20.2 272 88 52.4 0.38 11 5.04 19.7 264 85 71 45.27 0.94 19 4.95 19.7 256 74 44.0 0.90 20 4.91 19.5 254 73 40.6 0.87 21 4.79 19.0 246 71 59 44.5 0.83 17 4.91 19.5 254 73 43.2 0.79 17 4.87 19.3 251 73 39.9 0.76 18 4.75 18.8 244 71 46.61 0.84 18 5.05 20.2 276 79 45.3 0.81 19 5.01 20.0 273 78 41.8 0.78 19 4.89 19.4 265 76 63 46.1 0.69 15 5.01 20.0 273 78 44.8 0.66 15 4.97 19.8 270 77 41.4 0.64 15 4.85 19.2 262 75 50.46 0.64 15 5.21 20.8 291 86 49.0 0.61 15 5.17 20.6 288 85 45.2 0.59 16 5.05 20.1 280 83 67 50.6 0.48 11 5.17 20.6 288 85 49.1 0.46 11 5.13 20.5 285 84 45.3 0.44 12 5.01 19.9 277 82 115ºF 54.15 0.41 10 5.38 21.6 304 92 52.6 0.39 11 5.34 21.4 301 91 48.5 0.38 11 5.21 20.8 292 88 71 - Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 54.30 0.78 19 4.48 16.7 195 69 52.7 0.75 20 4.45 16.6 193 69 48.7 0.72 20 4.34 16.1 187 67 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 51.9 53.7 58.9 50.6 52.4 57.5 0.77 0.64 0.45 0.79 0.66 0.46 18 16 12 18 16 12 4.36 4.45 4.58 4.57 4.67 4.81 16.2 16.6 17.1 17.3 17.7 18.3 179 193 204 204 220 232 65 69 75 68 72 79 50.3 52.2 57.2 49.1 50.9 55.8 0.73 0.61 0.42 0.76 0.63 0.44 19 16 12 19 16 12 4.32 4.41 4.55 4.54 4.63 4.77 16.0 16.4 17.0 17.1 17.5 18.1 177 191 202 202 217 230 64 68 74 67 71 78 46.5 48.2 52.8 45.3 47.0 51.5 0.71 0.59 0.41 0.73 0.61 0.42 19 17 13 19 17 13 4.23 4.31 4.44 4.43 4.52 4.66 15.6 16.0 16.5 16.7 17.1 17.6 172 185 195 196 211 223 62 66 72 65 69 76 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130601A*** SS-VSH13 SS-VSH13 www.goodmanmfg.com 59 56.29 0.90 23 3.90 14.0 143 60 54.7 0.86 24 3.87 13.9 142 59 50.4 0.83 24 3.79 13.5 138 58 57.27 0.95 25 3.93 14.2 145 61 55.6 0.90 26 3.90 14.0 143 60 51.3 0.87 26 3.81 13.6 139 58 Airflow MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR 58.38 0.91 24 4.01 14.5 156 64 56.7 0.87 25 3.98 14.4 154 64 52.3 0.84 26 3.89 14.0 149 62 63 57.52 0.85 22 3.98 14.4 154 64 55.8 0.81 23 3.95 14.2 153 63 51.5 0.78 23 3.86 13.8 148 61 61.15 0.82 23 4.12 15.0 164 70 59.4 0.79 24 4.09 14.8 163 70 54.8 0.76 24 4.00 14.4 158 68 67 61.45 0.69 19 4.09 14.8 163 70 59.7 0.66 20 4.06 14.7 161 69 55.1 0.63 20 3.97 14.3 156 67 65.23 0.67 20 4.25 15.5 171 75 63.3 0.64 21 4.22 15.4 170 74 58.5 0.61 21 4.12 15.0 165 72 71 65.69 0.51 15 4.22 15.4 170 74 63.8 0.49 16 4.19 15.2 168 73 58.9 0.47 16 4.09 14.8 163 71 55.94 0.98 25 4.21 15.3 162 64 54.3 0.94 26 4.18 15.2 161 63 50.1 0.90 26 4.08 14.7 156 61 59 54.98 0.94 23 4.18 15.2 161 63 53.4 0.89 24 4.15 15.0 159 63 49.3 0.86 25 4.05 14.6 154 61 57.02 0.95 24 4.30 15.7 175 68 55.4 0.90 26 4.26 15.5 173 67 51.1 0.87 26 4.17 15.1 168 65 63 56.18 0.88 22 4.26 15.5 173 67 54.5 0.84 23 4.23 15.4 171 67 50.3 0.81 24 4.13 15.0 166 65 59.72 0.85 23 4.43 16.2 184 74 58.0 0.81 24 4.39 16.0 183 74 53.5 0.79 25 4.29 15.6 177 71 67 60.02 0.71 19 4.39 16.0 183 74 58.3 0.68 20 4.36 15.9 181 73 53.8 0.66 21 4.26 15.5 175 71 75ºF 63.72 0.69 20 4.56 16.8 192 79 61.9 0.66 21 4.53 16.6 190 78 57.1 0.64 21 4.42 16.2 185 76 71 64.16 0.53 16 4.53 16.6 190 78 62.3 0.51 16 4.49 16.5 189 78 57.5 0.49 16 4.39 16.0 183 75 IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves. 85 80 IDB 65ºF 54.61 1.00 25 4.46 16.6 185 66 53.0 0.96 26 4.43 16.5 183 66 48.9 0.92 26 4.32 16.0 177 64 55.67 0.97 25 4.55 17.0 199 71 54.0 0.93 26 4.52 16.9 197 70 49.9 0.89 26 4.41 16.4 191 68 62.20 0.71 20 4.84 18.3 219 82 60.4 0.68 21 4.80 18.1 217 81 55.7 0.65 21 4.69 17.6 210 79 53.28 1.00 24 4.68 17.8 210 70 51.7 0.99 26 4.64 17.6 208 69 47.7 0.95 27 4.53 17.1 202 67 54.31 1.00 25 4.78 18.2 226 74 52.7 0.96 26 4.74 18.0 224 74 48.7 0.92 26 4.63 17.5 217 71 56.88 0.90 23 4.93 18.8 239 81 55.2 0.86 24 4.89 18.6 237 80 51.0 0.83 25 4.77 18.1 229 78 60.68 0.73 20 5.08 19.5 249 86 58.9 0.70 21 5.04 19.3 247 86 54.4 0.67 21 4.92 18.8 239 83 50.61 1.00 23 4.87 18.9 237 73 49.1 1.00 25 4.83 18.7 234 72 45.4 0.99 26 4.71 18.2 227 70 59 49.74 1.00 23 4.83 18.7 234 72 48.3 0.98 24 4.79 18.6 232 72 44.6 0.94 25 4.68 18.1 225 70 51.59 1.00 23 4.97 19.4 255 78 50.1 0.99 25 4.93 19.2 252 77 46.2 0.96 26 4.81 18.7 244 75 63 50.83 0.96 22 4.93 19.2 252 77 49.4 0.92 23 4.89 19.0 250 76 45.6 0.89 24 4.78 18.5 242 74 54.04 0.94 23 5.13 20.0 269 85 52.5 0.89 24 5.09 19.8 266 84 48.4 0.86 24 4.96 19.3 258 82 67 54.31 0.78 19 5.09 19.8 266 84 52.7 0.75 20 5.04 19.7 263 83 48.7 0.72 20 4.92 19.1 256 81 105ºF 57.65 0.76 20 5.29 20.8 280 91 56.0 0.73 21 5.25 20.6 278 90 51.7 0.70 21 5.12 20.0 269 87 71 58.05 0.59 15 5.25 20.6 278 90 56.4 0.56 16 5.21 20.4 275 89 52.0 0.54 16 5.08 19.8 267 86 46.88 1.00 21 5.03 20.0 261 76 45.5 1.00 23 4.99 19.9 259 75 42.0 1.00 24 4.87 19.3 251 73 59 46.08 1.00 21 4.99 19.9 259 75 44.7 0.99 23 4.95 19.7 256 74 41.3 0.95 23 4.83 19.1 248 72 47.79 1.00 22 5.14 20.5 281 81 46.4 1.00 24 5.09 20.3 278 80 42.8 0.96 24 4.97 19.8 270 77 63 47.09 1.00 21 5.09 20.3 278 80 45.7 0.93 22 5.05 20.2 276 79 42.2 0.89 22 4.93 19.6 267 77 50.05 0.95 21 5.30 21.2 297 88 48.6 0.90 22 5.26 21.0 294 87 44.9 0.87 23 5.13 20.4 285 84 67 50.31 0.79 18 5.26 21.0 294 87 48.8 0.75 19 5.21 20.8 291 86 45.1 0.73 19 5.09 20.3 282 84 115ºF 53.40 0.77 19 5.47 22.0 310 94 51.8 0.73 19 5.43 21.8 307 93 47.9 0.71 20 5.29 21.2 297 90 71 53.78 0.59 14 5.43 21.8 307 93 52.2 0.56 15 5.38 21.6 304 92 48.2 0.54 15 5.25 21.0 295 89 Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions 58.30 0.88 23 4.69 17.6 210 77 56.6 0.84 24 4.66 17.4 208 76 52.2 0.81 25 4.55 17.0 201 74 Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 53.67 54.84 58.59 62.64 52.36 53.51 57.17 61.11 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.56 23 22 19 16 24 23 20 16 4.43 4.52 4.66 4.80 4.64 4.74 4.89 5.04 16.5 16.9 17.4 18.1 17.6 18.0 18.6 19.3 183 197 208 217 208 224 237 247 66 70 76 81 69 74 80 86 52.1 53.2 56.9 60.8 50.8 51.9 55.5 59.3 0.91 0.86 0.70 0.52 0.94 0.89 0.72 0.54 24 23 20 16 25 23 20 16 4.39 4.48 4.62 4.76 4.61 4.70 4.85 5.00 16.3 16.7 17.3 17.9 17.4 17.9 18.5 19.2 181 195 206 214 206 222 234 244 65 69 76 81 68 73 80 85 48.1 49.1 52.5 56.1 46.9 47.9 51.2 54.8 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 25 24 21 16 25 24 21 17 4.29 4.38 4.51 4.65 4.50 4.59 4.73 4.88 15.9 16.3 16.8 17.4 17.0 17.4 18.0 18.6 176 189 199 208 200 215 227 237 63 67 73 78 66 71 77 82 PRODUCT SPECIFICATIONS EXPANDED COOLING DATA — VSH130601A*** (CONT.) 25 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS Outdoor Unit Indoor Units Indoor Coil Furnace/Blower EER TVA Ratings Total Sens. Heating Capacity High HSPF Low ARI # 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314427 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314428 AR*F182416B* 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314429 ASPF183016B* 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314430 AT*F182416A* 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314431 CA*F1824*6C* G*E80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314432 CA*F1824*6C* G*V80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314433 CA*F1824*6C* G*V950453B** 18,000 13,100 13.5 11.8 16,700 13,000 16,800 7.7 8,600 3314434 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314435 MBE1200**-1B* 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3315416 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314436 CHPF1824A6A*+EEP CHPF2430B6B* G*E80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314437 CHPF2430B6B* G*V80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314438 CHPF2430B6B* G*V950453B** 18,000 13,100 13.5 11.8 16,700 13,000 16,800 7.7 8,600 3314439 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314440 14 12.2 16,700 13,000 16,800 8 8,600 3314441 CHPF2430B6B*+EEP CSCF1824N6A* G*E80704B** 18,000 13,100 CSCF1824N6A* G*V80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314442 CSCF1824N6A* G*V950453B** 18,000 13,100 13.5 11.8 16,700 13,000 16,800 7.7 8,600 3314443 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314444 CSCF1824N6A*+EEP CSCF3036N6B* G*E80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314445 CSCF3036N6B* G*V80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314446 CSCF3036N6B* G*V950453B** 18,000 13,100 13.5 11.8 16,700 13,000 16,800 7.7 8,600 3314447 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314448 14 12.2 16,700 13,000 16,800 8 8,600 3314449 CSCF3036N6B*+EEP CT*F1824*6A* G*E80704B** 18,000 13,100 CT*F1824*6A* G*V80704B** 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3314450 CT*F1824*6A* G*V950453B** 18,000 13,100 13.5 11.8 16,700 13,000 16,800 7.7 8,600 3314451 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314452 CT*F1824*6A*+EEP CT*F1824*6A* VSH13 0241A* SEER ADPF182416B* CA*F1824*6C* VSH13 0191A* Sens. AEPF183016C* CA*F1824*6C*+EEP VSH13 0181A* Cooling Capacity (BTU/h) Total 18,000 13,100 14 12.2 16,700 13,000 16,800 8 8,600 3315426 ACNF24XX16A* 18,000 13,100 13 11.5 16,700 13,000 16,800 7.7 8,600 3314453 AR*F182416B* 18,400 13,400 13 11.5 17,000 13,300 17,000 8 8,800 3314454 ASPF183016B* 18,000 13,100 14 12.2 16,700 13,000 17,000 8 8,800 3314455 AT*F182416A* 18,400 13,400 13 11.5 17,000 13,300 17,000 8 8,800 3314456 AWUF18XX16A* 18,000 13,100 13 11.5 16,700 13,000 16,800 7.8 8,600 3315554 AWUF24XX16A* 18,000 13,100 13 11.5 16,700 13,000 16,800 7.8 8,600 3315555 ADPF182416B* 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314457 AEPF183016C* 23,000 17,000 14 12.2 21,300 16,800 22,000 8 12,000 3314458 AEPF303616C* 23,400 17,300 14 12.2 21,700 17,000 22,000 8 12,000 3314459 AR*F182416B* 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314460 ASPF183016B* 23,000 17,000 14 12.2 21,300 16,800 22,000 8.2 12,000 3314461 ASPF303616B* 23,400 17,300 14 12.2 21,700 17,000 22,000 8 12,000 3314462 AT*F182416A* 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314463 AWUF30XX16B* 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314464 AWUF36XX16B* 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314465 23,000 17,000 14 12.2 21,300 16,800 22,000 8 12,000 3315417 CA*F1824*6C* MBE1200**-1B* MBE1200**-1B* See Notes on Page 32. 26 www.goodmanmfg.com SS-VSH13 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit Indoor Units Indoor Coil Furnace/Blower EER Total Sens. High HSPF Low ARI # G*E80704B** 23,000 17,000 14 12.2 21,300 16,800 22,000 7.7 12,000 3314466 G*V80704B** 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314467 CA*F3030*6B* G*V950453B** 23,000 17,000 13 11.8 21,300 16,800 22,000 7.7 12,000 3314468 CA*F3030*6B*+EEP 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314469 CHPF1824A6A*+EEP 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314470 CHPF2430B6B* G*E80704B** 23,000 17,000 14 12.2 21,300 16,800 22,000 7.7 12,000 3314471 CHPF2430B6B* G*V80704B** 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314472 CHPF2430B6B* G*V950453B** 23,000 17,000 13.5 11.8 21,300 16,800 22,000 7.7 12,000 3314473 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314474 CSCF1824N6A* G*E80704B** 23,000 17,000 14 12.2 21,300 16,800 22,000 7.7 12,000 3314475 CSCF1824N6A* G*V80704B** 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314476 CSCF1824N6A* G*V950453B** 23,000 17,000 13.5 11.8 21,300 16,800 22,000 7.7 12,000 3314477 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314478 CSCF3036N6B* G*E80704B** 23,000 17,000 14 12.2 21,300 16,800 22,000 7.7 12,000 3314479 CSCF3036N6B* G*V80704B** 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314480 CSCF3036N6B* G*V950453B** 23,000 17,000 13.5 11.8 21,300 16,800 22,000 7.7 12,000 3314481 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314482 CT*F1824*6A* MBE1200**-1B* 23,000 17,000 14 12.2 21,300 16,800 22,000 8 12,000 3315427 CT*F3030*6A* G*E80704B** 23,000 17,000 14 12.2 21,300 16,800 22,000 7.7 12,000 3314483 CT*F3030*6A* G*V80704B** 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314484 CT*F3030*6A* G*V950453B** 23,000 17,000 13 11.8 21,300 16,800 22,000 7.7 12,000 3314485 CSCF3036N6B*+EEP VSH13 0301A* Heating Capacity SEER CA*F3030*6B* CSCF1824N6A*+EEP VSH13 0251A* TVA Ratings Sens. CA*F3030*6B* CHPF2430B6B*+EEP VSH13 0241A* (cont.) Cooling Capacity (BTU/h) Total CT*F3030*6A*+EEP 23,000 17,000 13 11.5 21,300 16,800 22,000 7.7 12,000 3314486 ACNF24XX16A* 23,600 17,400 13 11.5 21,800 17,200 22,600 7.7 12,400 3314487 AR*F182416B* 24,000 17,600 13 11.5 22,200 17,500 22,600 8 12,400 3314488 ASPF183016B* 23,000 17,000 14 12.2 21,300 16,800 22,000 8 12,000 3314489 ASPF303616B* 23,400 17,300 14 12.2 21,600 17,100 23,600 7.8 12,400 3314490 AT*F182416A* 24,000 17,600 13 11.5 22,200 17,500 22,600 8 12,400 3314491 AWUF24XX16A* 23,000 17,000 13 11.5 21,300 16,800 22,600 7.8 12,400 3315556 AWUF30XX16B* 23,600 17,400 13 11.5 21,800 17,200 22,600 7.8 12,400 3314492 AWUF36XX16B* 23,600 17,400 13 11.5 21,800 17,200 22,600 7.8 12,400 3314493 ADPF304216B* 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314494 AEPF183016C* 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314495 AEPF303616C* 29,000 21,800 14 12.2 26,800 21,400 26,800 8 14,000 3314496 AR*F182416B*+TXV 27,800 20,900 13 11.5 25,700 20,600 26,600 7.7 14,000 3314497 AR*F303016B* 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314498 ASPF183016B* 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314499 ASPF303616B* 28,400 21,300 14 12.2 25,900 20,700 26,800 8 14,000 3314500 AT*F303016A* 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314501 AWUF37XX16B* 28,400 21,300 13 11.5 25,900 20,700 25,000 7.8 15,000 3314502 CA*F3131*6C* G*V80704B** 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314503 CA*F3131*6C* G*V950704C** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.8 14,000 3314504 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314505 CA*F3131*6C*+EEP CA*F3131*6C* MBE1200**-1B* 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.8 14,000 3315418 CA*F3636*6B* G*E80704B** 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314506 See Notes on Page 32. SS-VSH13 www.goodmanmfg.com 27 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit Indoor Units Indoor Coil Furnace/Blower CA*F3636*6B*+EEP VSH13 0361A* SEER EER TVA Ratings Total Sens. Heating Capacity High HSPF Low ARI # 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314507 G*V80704B** 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314508 CHPF2430B6B* G*V90704C** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.7 14,000 3314509 CHPF2430B6B* G*V950704C** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.7 14,000 3314510 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314511 CSCF3036N6B* G*V80704B** 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314512 CSCF3036N6B* G*V90704C** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.7 14,000 3314513 CSCF3036N6B* G*V950704C** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.7 14,000 3314514 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314515 CSCF3642N6C* G*E80704B** 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314516 CT*F3131*6A* G*V80704B** 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314517 CT*F3131*6A* G*V950453B** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.7 14,000 3314518 CT*F3131*6A* G*V950704C** 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.8 14,000 3314519 28,000 21,000 13 11.5 25,900 20,700 26,800 7.7 14,000 3314520 CT*F3131*6A* MBE1200**-1B* 28,000 21,000 13.5 11.8 25,900 20,700 26,800 7.8 14,000 3315428 CT*F3131*6A*+TXV MBE1200**-1B* 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3315429 CT*F3636*6A* G*E80704B** 14,000 3314521 CSCF3036N6B*+EEP CT*F3131*6A*+EEP VSH13 0311A* Sens. CHPF2430B6B* CHPF2430B6B*+EEP VSH13 0301A* (cont.) Cooling Capacity (BTU/h) Total 28,000 21,000 14 12.2 25,900 20,700 26,800 8 ACNF30XX16A* 27,000 21,100 13 11.5 25,000 20,800 25,600 7.7 14,000 3314522 AR*F303016B* 28,000 21,000 13 11.5 25,900 20,700 26,000 8 15,000 3314523 ASPF183016B* 28,000 21,000 14 12.2 25,900 20,700 26,800 8 14,000 3314524 ASPF303616B* 28,400 21,300 14 12.2 26,300 21,000 26,800 8 14,000 3314525 AT*F303016A* 28,000 21,000 13 11.5 25,900 20,700 26,000 8 15,000 3314526 AWUF30XX16B* 27,400 21,400 13 11.5 25,300 21,000 25,600 8 14,400 3314527 AWUF36XX16B* 27,400 21,400 13 11.5 25,300 21,000 25,600 8 14,400 3314528 AWUF37XX16B* 27,400 21,400 13 11.5 25,300 21,000 26,000 8 15,000 3314529 ADPF304216B* 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314530 AEPF303616C* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314531 AEPF426016C* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314532 AR*F363616B* 34,400 26,100 13 11.5 31,800 25,800 32,600 7.8 16,000 3314533 AR*F364216B* 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314534 AR*F374316B* 35,000 26,600 13 11.5 32,400 26,200 34,000 8 19,400 3314535 ASPF303616B* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314536 ASPF426016B* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314537 AT*F363616A* 34,400 26,100 13 11.5 31,800 25,800 32,600 7.8 16,000 3314538 AT*F364216A* 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314539 AWUF37XX16B* 33,400 25,400 13 11.5 30,900 25,000 31,000 7.8 17,000 3314540 CA*F3636*6B* G*V90704C** 33,600 25,500 13.5 11.8 31,100 25,200 32,000 8 16,000 3314541 CA*F3642*6B* G*E80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314542 CA*F3642*6B* G*V80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314543 CA*F3642*6B* G*V81155C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314544 CA*F3642*6B* G*V90905D** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314545 CA*F3642*6B* G*V950905D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314546 CA*F3642*6B* G*V951155D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314547 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314548 CA*F3642*6B*+EEP See Notes on Page 32. 28 www.goodmanmfg.com SS-VSH13 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit Indoor Units Indoor Coil Furnace/Blower TVA Ratings Heating Capacity Sens. SEER EER Total Sens. High HSPF Low ARI # CA*F3642*6B* MBE1600**-1B* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3315419 CA*F3743*6A* G*E80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314549 CA*F3743*6A* G*V80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314550 CA*F3743*6A* G*V81155C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314551 CA*F3743*6A* G*V90905D** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314552 CA*F3743*6A* G*V950704C** 34,000 25,800 13.5 11.8 31,500 25,500 32,000 8 16,000 3314553 CA*F3743*6A* G*V950905D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314554 CA*F3743*6A* G*V951155D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314555 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314556 CA*F3743*6A* MBE1600**-1B* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3315421 CA*F3743*6A*+TXV G*V90704C** 34,400 26,100 13.5 11.8 31,800 25,800 32,000 8 16,000 3314557 CA*F3743*6A*+TXV G*V950704C** 34,000 25,800 13.7 12 31,500 25,500 32,000 8 16,000 3314558 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314559 CA*F3743*6A*+EEP CHPF3636B6B*+EEP CHPF3642C6B* G*E80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 7.8 16,000 3314560 CHPF3642C6B* G*V80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 7.7 16,000 3314561 CHPF3642C6B* G*V81155C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314562 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314563 CHPF3642D6B* G*V90905D** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314564 CHPF3642D6B* G*V950905D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314565 CHPF3642D6B* G*V951155D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314566 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314567 CHPF3642C6B*+EEP VSH13 0361A* (cont.) Cooling Capacity (BTU/h) Total CHPF3642D6B*+EEP CSCF3642N6C* G*E80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314568 CSCF3642N6C* G*V80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314569 CSCF3642N6C* G*V81155C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314570 CSCF3642N6C* G*V90905D** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314571 CSCF3642N6C* G*V950905D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314572 CSCF3642N6C* G*V951155D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314573 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314574 CSCF3642N6C*+EEP CT*F3636*6A* G*V950704C** 33,600 25,500 13.5 11.8 31,100 25,200 32,000 8 16,000 3314575 CT*F3636*6A*+TXV G*V950704C** 33,600 25,500 13.7 12 31,100 25,200 32,000 8 16,000 3314576 CT*F3642*6A* G*E80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314577 CT*F3642*6A* G*V80905C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314578 CT*F3642*6A* G*V81155C** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314579 CT*F3642*6A* G*V90905D** 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3314580 CT*F3642*6A* G*V950704C** 34,000 25,800 13.5 11.8 31,500 25,500 32,000 8 16,000 3314581 CT*F3642*6A* G*V950905D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314582 CT*F3642*6A* G*V951155D** 35,000 26,600 13.5 11.8 32,400 26,200 32,000 7.7 16,000 3314583 35,000 26,600 13 11.5 32,400 26,200 32,000 7.7 16,000 3314584 CT*F3642*6A*+EEP CT*F3642*6A* MBE1600**-1B* 35,000 26,600 14 12.2 32,400 26,200 32,000 8 16,000 3315430 CT*F3642*6A*+TXV G*V90704C** 34,400 26,100 13.5 11.8 31,800 25,800 32,000 8 16,000 3314585 CT*F3642*6A*+TXV G*V950704C** 34,000 25,800 13.7 12 31,500 25,500 32,000 8 16,000 3314586 See Notes on Page 32. SS-VSH13 www.goodmanmfg.com 29 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit Indoor Units Indoor Coil Heating Capacity SEER EER Total Sens. High HSPF ADPF304216B* 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314587 AEPF426016C* 41,000 31,200 14 12.2 37,900 30,700 39,500 8.2 23,000 3314588 AR*F364216B* 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314589 ASPF426016B* 41,000 31,200 14 12.2 37,900 30,700 39,500 8.2 23,000 3314590 AT*F364216A* 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314591 CA*F3642*6B*+EEP 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314592 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3315420 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314593 MBE1600**-1B* Low ARI # Sens. CA*F3743*6A*+EEP CA*F3743*6A* MBE1600**-1B* 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3315422 CA*F4860*6B* G*E80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314594 CA*F4860*6B* G*E81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314595 CA*F4860*6B* G*V80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314596 CA*F4860*6B* G*V81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314597 CA*F4860*6B* G*V90905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314598 CA*F4860*6B* G*V950905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314599 CA*F4860*6B* G*V951155D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314600 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314601 CHPF3642C6B*+EEP CHPF3642D6B*+EEP VSH13 0421A* TVA Ratings Total CA*F3642*6B* Furnace/Blower Cooling Capacity (BTU/h) 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314602 CHPF4860D6C* G*E80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314603 CHPF4860D6C* G*E81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314604 CHPF4860D6C* G*V80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314605 CHPF4860D6C* G*V81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314606 CHPF4860D6C* G*V90905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314607 CHPF4860D6C* G*V950905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314608 CHPF4860D6C* G*V951155D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314609 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314610 CSCF3642N6C*+EEP CSCF4860N6C* G*E80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314611 CSCF4860N6C* G*E81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314612 CSCF4860N6C* G*V80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314613 CSCF4860N6C* G*V81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314614 CSCF4860N6C* G*V90905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314615 CSCF4860N6C* G*V950905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314616 CSCF4860N6C* G*V951155D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314617 40,000 30,400 13 11.5 37,000 30,000 39,000 8 23,000 3314618 CT*F3642*6A* MBE1600**-1B* 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3315431 CT*F4860*6A* G*E80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314619 CT*F4860*6A* G*E81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314620 CT*F4860*6A* G*V80905C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314621 CT*F4860*6A* G*V81155C** 41,000 31,200 14 12.2 37,900 30,700 39,000 8.2 23,000 3314622 CT*F4860*6A* G*V90905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314623 CT*F4860*6A* G*V950905D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314624 CT*F4860*6A* G*V951155D** 41,000 31,200 13.5 11.8 37,900 30,700 39,000 8 23,000 3314625 CT*F3642*6A*+EEP See Notes on Page 32. 30 www.goodmanmfg.com SS-VSH13 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit Indoor Units Indoor Coil Furnace/Blower TVA Ratings Heating Capacity Low ARI # Total Sens. SEER EER Total Sens. High HSPF ADPF486016B* 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314626 AEPF426016C* 45,000 34,200 14 12.2 41,600 33,700 43,000 8.4 27,000 3314627 AR*F486016B* 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314628 AR*F496116A* 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314629 ASPF426016B* 45,000 34,200 14 12.2 41,600 33,700 43,000 8.4 27,000 3314630 AT*F486016A* 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314631 CA*F4860*6B* G*E80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314632 CA*F4860*6B* G*E81155C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314633 CA*F4860*6B* G*V80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314634 CA*F4860*6B* G*V81155C** 45,000 34,200 14 12.2 41,600 33,700 43,000 8.4 27,000 3314635 CA*F4860*6B* G*V90905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314636 CA*F4860*6B* G*V950905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314637 CA*F4860*6B* G*V951155D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314638 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314639 CA*F4860*6B*+EEP VSH13 0481A* Cooling Capacity (BTU/h) CA*F4860*6B* MBE2000**-1B* 45,000 34,200 14 12.2 41,600 33,700 43,000 8.4 27,000 3315423 CHPF4860D6C* G*E80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314640 CHPF4860D6C* G*E81155C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314641 CHPF4860D6C* G*V80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314642 CHPF4860D6C* G*V81155C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314643 CHPF4860D6C* G*V90905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314644 CHPF4860D6C* G*V950905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314645 CHPF4860D6C* G*V951155D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314646 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314647 45,000 34,200 14 12.2 41,600 33,700 45,000 8.5 26,000 3315425 CHPF4860D6C*+EEP CHPF4860D6C* MBE2000**-1B* CHPF4860D6C*+TXV MBE2000**-1B* 45,500 34,400 14.5 12 41,800 33,900 45,000 8.5 26,000 3314648 CSCF4860N6C* G*E80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314649 CSCF4860N6C* G*E81155C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314650 CSCF4860N6C* G*V80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314651 CSCF4860N6C* G*V81155C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314652 CSCF4860N6C* G*V90905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314653 CSCF4860N6C* G*V950905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314654 CSCF4860N6C* G*V951155D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314655 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314656 CSCF4860N6C*+EEP CT*F4860*6A* G*E80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314657 CT*F4860*6A* G*E81155C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314658 CT*F4860*6A* G*V80905C** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314659 CT*F4860*6A* G*V81155C** 45,000 34,200 14 12.2 41,600 33,700 43,000 8.4 27,000 3314660 CT*F4860*6A* G*V90905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314661 CT*F4860*6A* G*V950905D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314662 CT*F4860*6A* G*V951155D** 45,000 34,200 13.5 11.8 41,600 33,700 43,000 8.3 27,000 3314663 45,000 34,200 13 11.5 41,600 33,700 43,000 8.2 27,000 3314664 45,000 34,200 14 12.2 41,600 33,700 43,000 8.4 27,000 3315432 CT*F4860*6A*+EEP CT*F4860*6A* MBE2000**-1B* See Notes on Page 32. SS-VSH13 www.goodmanmfg.com 31 PRODUCT SPECIFICATIONS ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit VSH13 0601A* Indoor Units Indoor Coil Furnace/Blower Cooling Capacity (BTU/h) SEER EER TVA Ratings Total Sens. Heating Capacity High HSPF Low ARI # Total Sens. ADPF486016B* 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314665 AEPF426016C* 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.6 35,000 3314666 AR*F486016B* 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314667 AR*F496116A* 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314668 ASPF426016B* 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.6 35,000 3314669 ASPF426016B*+TXV 55,500 40,000 14 12.2 51,300 39,500 55,500 8.6 35,000 3314670 AT*F486016A* 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314671 CA*F4860*6B* G*V80905C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314672 CA*F4860*6B* G*V81155C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314673 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314674 CA*F4860*6B*+EEP CA*F4860*6B* MBE2000**-1B* 55,500 40,000 13.5 11.8 51,300 39,500 55,500 8.6 35,000 3315424 CHPF4860D6C* G*V80905C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314675 CHPF4860D6C* G*V81155C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314676 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314677 CSCF4860N6C* G*V80905C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314678 CSCF4860N6C* G*V81155C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314679 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314680 CT*F4860*6A* G*V80905C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314681 CT*F4860*6A* G*V81155C** 55,500 40,000 13.3 11.7 51,300 39,500 55,500 8.5 35,000 3314682 55,500 40,000 13 11.5 51,300 39,500 55,500 8.5 35,000 3314683 MBE2000**-1B* 55,500 40,000 13.5 11.8 51,300 39,500 55,500 8.6 35,000 3315433 CHPF4860D6C*+EEP CSCF4860N6C*+EEP CT*F4860*6A*+EEP CT*F4860*6A* ¹ Seasonal Energy Efficiency Ratio; Certified per ARI 210/240 @ 80°F/ 67°F/ 95°F ² Energy Efficiency Ratio @ 80 °F/67 °F Inside - 95 °F Notes: • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP: Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay. 32 www.goodmanmfg.com SS-VSH13 PRODUCT SPECIFICATIONS DIMENSIONS W D H Dimensions Model SS-VSH13 W" D" H" VSH130181A* 26 26 32¼ VSH130191A* 29 29 34¼ VSH130241A* 26 26 32¼ VSH130251A* 29 29 34¾ VSH130301A* 26 26 34¼ VSH130311A* 29 29 34¾ VSH130361A* 29 29 38¼ VSH130421A* 29 29 32¼ VSH130481A* 29 29 34¾ VSH130601A* 35½ 35½ 34¾ www.goodmanmfg.com 33 34 L2 L1 1 SR www.goodmanmfg.com IO CM AUX MAIN BK O O OR BR BK PU BL YL ALTERNATE DOUBLE POLE CONTACTOR T2 T1 YL 2 5 BK BL C Y BK H V D R BK S DF1 DF2 BK YL RD RD BK BK WARNING CH (IF USED) NOTE 3 R AUX MAIN COMP RD DFT C BK RD R R RD YL RD WH W2 LVDR DC BK YL YL BK L1 T1 BK L2 T2 RCCF YL YL BL HERM YL F SA (IF USED) NOTE 2 RD BR C RD RD RD YL EQUIPMENT GROUND USE COPPER CONDUCTORS ONLY RD PU C RD RD Y YL L1 C R R T1 IO LVDR DFT SR O W2 DFT 2 M AI N X AU Y DC C (IF USED) NOTE 3 CH CM IO X S AU COMP M AI N R DF2 HVDR DF1 C 5 F SC C (IF USED) SA RCCF RVC H 1 OUTDOOR POWER SUPPLY SEE RATING PLATE T2 C VENDOR: GOODMAN PRINT SHOP CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. 07/05 L2 0140R00019P USE N.E.C. CLASS 2 WIRE COMPONENT CODE C LPS O C --------------- CONTACTOR CH ------------- CRANKCASE HEATER CM ------------ OUTDOOR FAN MOTOR R C COMP -------- COMPRESSOR W2 O Y DC ------------- DEFROST CONTROL DFT ----------- DEFROST THERMOSTAT INDOOR POWER HVDR -------- HIGH VOLTAGE DEFROST RELAY SUPPLY IO -------------- INTERNAL OVERLOAD LPS ------------ LOW PRESSURE SWITCH LVDR --------- LOW VOLTAGE DEFROST RELAY NOTES: 1) TO INDOOR UNIT LOW VOLTAGE LVJB ---------- LOW VOLTAGE JUNCTION BOX TERMINAL BLOCK & INDOOR RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN THERMOSTAT. 2) START ASSIST FACTORY RVC ----------- REVERSING VALVE COIL EQUIPPED WHEN REQUIRED. 3) CRANKCASE HEATER MAY BE SA ------------- START ASSIST FACTORY OR FIELD INSTALLED. SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL) FIELD WIRING HIGH VOLTAGE LOW VOLTAGE WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW NOTE 1 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. LPS DFT RVC YL BL BK BK BL BK BK SC O OR C W2 WH BL R RD LVJB ALTERNATE DOUBLE POLE CONTACTOR ONLY CONTROL BOX PRODUCT SPECIFICATIONS WIRING DIAGRAM Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring schematic. SS-VSH13 PRODUCT SPECIFICATIONS ACCESSORIES Model VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 018 019 024 025 030 031 036 042 048 060 ABK-20 Anchor Bracket Kit ▼ X X X X X X X X X X AFE18-60A All-fuel Kit X X X X X X X X X X ASC01 Anti-Short Cycle Kit X X X X X X X X X X TBA Hard-start Kit X X X X X X X TBA Hard-start Kit X X X TBA Hard-start Kit X X FSK01A¹ Freeze Protection Kit X X X X X X X X X X OT/EHR18-60 Emergency Heat Relay kit X X X X X X X X X X OT18-60A² Outdoor Thermostat with Lockout Stat X X X X X X X X X X TX3N2³ TXV Kit -- Field-installed, nonbleed, expansion valve kit X X X X X X X TX5N2³ TXV Kit -- Field-installed, nonbleed, expansion valve kit X X X ▼ ¹ ² ³ Description X Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Required for heat pump applications where ambient temperatures fall below 0 °F with 50% or higher relative humidity. Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device. SS-VSH13 www.goodmanmfg.com 35 PRODUCT SPECIFICATIONS NOTES Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright © 2009 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 36 www.goodmanmfg.com SS-VSH13