Transcript
VSH13 13 SEER SPLIT SYSTEM HEAT PUMP
PRODUCT SPECIFICATIONS
The VSH13 heat pump features a louvered metal guard that protects the coil from damage and strengthens the unit. Designed for ground-level or rooftop mount, the unit has a base pan that elevates it above the slab for excellent water drainage.
Standard Features • • • • • • • • •
Energy-efficient compressor R-22 refrigerant-charged for 15’ of refrigerant lines Quiet condenser fan system Copper tube/aluminum fin coil Liquid refrigerant return protection Factory-installed bi-flow liquid line filter dryer Low-pressure switch Time-initiated, temperature-terminated defrost control Service valves with sweat connections and easy-access gauge ports • 13 SEER performance with flowrater expansion device • Ground lug connection • ARI Certified; ETL Listed
13 SEER
Cabinet Features
18,000 TO 60,000 BTU/H
• Louver design sound control top for quiet operation • Steel louver coil guard • Heavy-gauge, galvanized-steel cabinet with rustresistant screws • Attractive Bahama Beige powder-paint finish with 500-hour salt-spray approval • Single-panel access to controls with space provided for field-installed accessories • When properly anchored, meets the 2001 Florida Building Code unit integrity requirements for hurricane-type winds
NOMINAL HEATING CAPACITY
Contents
1½ - 5 TONS NOMINAL COOLING CAPACITY 17,200 TO 54,300 BTU/H
Nomenclature ........................................................................ 2 Product Specifications ........................................................... 3 Expanded Heating Data ......................................................... 4 Expanded Cooling Data ......................................................... 6 ARI Performance Data ........................................................ 26 Dimensions .......................................................................... 33 Wiring Diagrams .................................................................. 34 Accessories ........................................................................... 35
* Full warranty details available at www.goodmanmfg.com.
SS-VSH13
www.goodmanmfg.com
3/09
PRODUCT SPECIFICATIONS
NOMENCLATURE V
S
H
13
18
1
A
A
1
2
3
4,5
6,7,8
9
10
11
Brand V GMC Product Family
Engineering * Minor Revision Engineering * Major Revision
Product Category S Split System
Unit Type C Condenser R-22 H Heat Pump R-22
Efficiency 13 13 SEER
1 2
018 024 030 036
Electrical 208/230 V, 1 Phase, 60 Hz 220/240 V, 1 Phase, 50 Hz
1½ Tons 2 Tons 2½ Tons 3 Tons
Nominal Capacity 042 3½ Tons 048 4 Tons 060 5 Tons
* Neither used for order entry or inventory management.
2
www.goodmanmfg.com
SS-VSH13
PRODUCT SPECIFICATIONS
SPECIFICATIONS VSH13 0181AA
VSH13 0191AA
VSH13 0241AA
VSH13 0251AA
VSH13 0301AA
VSH13 0311AA
VSH13 0361AA
VSH13 0421AA
VSH13 0481AA
VSH13 0601AA
Nominal Cooling (BTU/h)
18,000
18,000
23,000
23,000
28,000
28,000
35,000
40,000
45,000
55,500
Nominal Heating (BTU/h)
16,800
16,800
22,000
22,600
26,800
25,600
32,000
39,000
43,000
55,500
Capacities and Ratings
SEER
13
13
13
13
13
13
13
13
13
13
Decibels
78
78
78
78
78
76
80
76
76
77
Compressor RLA
6.2
9.0
9.2
10.9
10.8
12.2
12.2
16.5
17.9
25.0
LRA
34.0
41.0
43.0
54.0
60.0
63.0
73.0
95.0
104.0
148.0
Type
Recip
Scroll
Recip
Scroll
Recip
Scroll
Recip
Scroll
Scroll
Scroll
Horsepower
1/6
1/6
1/6
1/6
1/6
1/6
¼
¼
¼
1/6
FLA
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.6
1.6
1.1
Condenser Fan Motor
Refrigerant System Refrigerant Line Size¹ Liquid Line Size (“O.D.)
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
Suction Line Size (“O.D.)
¾”
¾”
¾”
¾”
¾”
¾”
⅞”
1⅛”
1⅛”
1⅛”
Refrigerant Connection Size Liquid Valve Size (“O.D.)
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
⅜”
Suction Valve Size (“O.D.)
¾”
¾”
¾”
¾”
¾”
¾”
⅞”
⅞”
⅞”
⅞”
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
Sweat
127
115
106
117
153
153
188
213
223
233
0.052
0.052
0.061
0.061
0.068
0.065
0.073
0.082
0.084
0.093
AC Volts
208/230
208/230
208/230
208/230
208/230
208/230
208/230
208/230
208/230
208/230
Frequency-Phase
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
60 Hz/1
Minimum Circuit Ampacity ²
9.3
12.7
13.0
15.1
15.0
16.7
16.9
22.3
27.8
32.3
Max. Overcurrent Protection ³
15
20
20
20
20
20
20
30
40
50
Valve Type Refrigerant Charge Shipped with Orifice Size Electrical Data
Min / Max Volts
197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253 197 / 253
Electrical Conduit Size
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
½” or ¾”
193
193
198
207
199
199
207
219
225
266
Ship Weight (lbs)
¹ Tested and rated in accordance with ARI Standard 210/240 ² Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes ³ Must use time-delay fuses or HACR-type circuit breakers of the same size as noted. Notes • Always check the S&R plate for electrical data on the unit being installed. • Installer will need to supply ⅞” to 1⅛” adapters for suction line connections. • Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure. • Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
SS-VSH13
www.goodmanmfg.com
3
PRODUCT SPECIFICATIONS
EXPANDED HEATING DATA VSH130181A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 21.1 32.6 1.57 7.3 3.94 13.5 241 83
60 20.0 30.9 1.54 6.8 3.80 13.0 231 77
55 18.8 29.0 1.51 6.4 3.65 12.5 222 72
50 17.6 27.1 1.48 6.0 3.48 11.9 213 66
47 16.8 25.9 1.46 5.8 3.36 11.5 208 62
45 16.3 25.1 1.45 5.7 3.29 11.2 204 60
40 15.1 23.3 1.42 5.4 3.12 10.6 196 55
Outdoor Ambient Temperature 35 30 25 20 17 13.9 10.7 9.9 9.1 8.6 21.5 16.5 15.3 14.1 13.3 1.39 1.30 1.27 1.24 1.23 5.1 4.9 4.7 4.4 4.3 2.94 2.41 2.28 2.14 2.05 10.0 8.2 7.8 7.3 7.0 188 180 172 165 161 49 44 40 35 32
15 8.3 12.8 1.22 4.3 1.99 6.8 158 31
10 7.4 11.5 1.19 4.1 1.83 6.3 152 26
5 6.6 10.2 1.16 3.8 1.66 5.7 146 23
0 5.7 8.9 1.13 3.6 1.49 5.1 140 19
-5 4.9 7.6 1.10 3.3 1.30 4.4 135 17
-10 4.0 6.2 1.08 3.0 1.09 3.7 131 13
60 20.0 30.9 1.63 5.9 3.59 12.3 178 78
55 18.8 29.0 1.60 5.5 3.45 11.8 171 73
50 17.6 27.1 1.57 5.2 3.29 11.2 164 67
47 16.8 25.9 1.55 5.1 3.17 10.8 160 64
45 16.3 25.1 1.54 5.0 3.10 10.6 157 61
40 15.1 23.3 1.51 4.7 2.94 10.0 151 56
Outdoor Ambient Temperature 35 30 25 20 17 13.9 10.7 9.9 9.1 8.6 21.5 16.5 15.3 14.1 13.3 1.48 1.51 1.47 1.44 1.42 4.5 4.3 4.2 4.0 3.9 2.76 2.08 1.96 1.85 1.77 9.4 7.1 6.7 6.3 6.0 145 139 132 127 124 50 45 40 36 33
15 8.3 12.8 1.41 3.9 1.72 5.9 122 32
10 7.4 11.5 1.38 3.7 1.58 5.4 117 27
5 6.6 10.2 1.35 3.5 1.43 4.9 113 23
0 5.7 8.9 1.32 3.3 1.28 4.4 108 20
-5 4.9 7.6 1.28 3.1 1.12 3.8 104 17
-10 4.0 6.2 1.25 2.8 0.94 3.2 101 13
60 26.2 29.6 2.05 8.9 3.73 12.8 250 74
55 24.6 27.8 2.01 8.3 3.58 12.2 240 70
50 23.0 26.0 1.97 7.8 3.42 11.7 230 64
47 22.0 24.8 1.95 7.6 3.30 11.3 224 61
45 21.3 24.1 1.93 7.4 3.23 11.0 220 58
40 19.8 22.4 1.89 7.0 3.06 10.5 212 54
Outdoor Ambient Temperature 35 30 25 20 17 18.3 15.0 13.8 12.7 12.0 20.6 16.9 15.6 14.3 13.6 1.85 1.76 1.73 1.69 1.66 6.6 6.4 6.1 5.8 5.7 2.89 2.48 2.34 2.20 2.11 9.9 8.5 8.0 7.5 7.2 203 195 186 178 174 48 43 38 34 31
15 11.6 13.0 1.65 5.6 2.05 7.0 171 30
10 10.4 11.7 1.61 5.3 1.89 6.4 164 26
5 9.2 10.4 1.57 4.9 1.71 5.9 158 22
0 8.0 9.1 1.53 4.7 1.53 5.2 152 19
-5 6.8 7.7 1.49 4.3 1.34 4.6 146 16
-10 5.6 6.3 1.46 3.9 1.13 3.9 141 13
60 26.9 30.4 2.27 10.3 3.47 11.8 170 71
55 25.3 28.6 2.23 9.7 3.33 11.4 164 66
50 23.7 26.7 2.18 9.1 3.17 10.8 157 61
47 22.6 25.5 2.16 8.8 3.07 10.5 153 58
45 21.9 24.7 2.14 8.7 3.00 10.2 150 55
40 20.3 23.0 2.10 8.2 2.84 9.7 144 51
Outdoor Ambient Temperature 35 30 25 20 17 18.8 17.1 15.7 14.5 13.7 21.2 19.3 17.8 16.4 15.5 2.05 1.90 1.86 1.82 1.80 7.8 7.5 7.2 6.9 6.8 2.67 2.62 2.48 2.33 2.23 9.1 9.0 8.5 8.0 7.6 138 133 127 122 119 45 41 37 32 30
15 13.2 14.9 1.78 6.7 2.17 7.4 117 29
10 11.8 13.4 1.74 6.4 1.99 6.8 112 24
5 10.5 11.8 1.70 6.0 1.81 6.2 108 21
0 9.1 10.3 1.66 5.7 1.61 5.5 103 18
-5 7.8 8.8 1.62 5.3 1.41 4.8 100 15
-10 6.4 7.2 1.58 4.9 1.19 4.0 96 12
60 31.9 28.1 2.36 10.3 3.95 13.5 224 70
55 30.0 26.5 2.32 9.6 3.79 13.0 216 66
50 28.1 24.7 2.27 9.1 3.62 12.4 206 61
47 26.8 23.6 2.24 8.7 3.50 11.9 202 57
45 26.0 22.9 2.22 8.6 3.42 11.7 198 55
40 24.1 21.3 2.18 8.1 3.24 11.1 190 51
Outdoor Ambient Temperature 35 30 25 20 17 22.2 17.4 16.1 14.8 14.0 19.6 15.4 14.2 13.1 12.3 2.13 2.08 2.04 1.99 1.96 7.7 7.3 7.0 6.7 6.5 3.05 2.45 2.31 2.18 2.09 10.4 8.4 7.9 7.4 7.1 182 175 167 160 156 45 41 36 32 30
15 13.5 11.9 1.95 6.4 2.03 6.9 154 29
10 12.1 10.7 1.90 6.1 1.86 6.4 148 24
5 10.7 9.5 1.85 5.7 1.69 5.8 142 21
0 9.4 8.2 1.81 5.3 1.51 5.2 136 18
-5 8.0 7.0 1.76 4.9 1.32 4.5 131 15
-10 6.5 5.8 1.72 4.4 1.11 3.8 127 12
VSH130191A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 21.1 32.6 1.66 6.3 3.73 12.7 186 84
VSH130241A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 27.7 31.2 2.09 9.6 3.87 13.2 261 80
VSH130251A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 28.4 32.1 2.31 11.1 3.59 12.3 178 76
VSH130301A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 33.7 29.7 2.41 11.1 4.09 14.0 234 76
High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70 °F indoor dry bulb.
4
www.goodmanmfg.com
Amps = Outdoor unit amps (comp.+fan) kW = Total system power
SS-VSH13
PRODUCT SPECIFICATIONS
EXPANDED HEATING DATA (CONT.) VSH130311A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 32.2 28.4 2.55 12.6 3.70 12.6 254 76
60 30.5 26.9 2.49 11.7 3.58 12.2 243 71
55 28.7 25.3 2.44 11.0 3.44 11.8 234 66
50 26.8 23.6 2.39 10.3 3.29 11.2 224 61
47 25.6 22.6 2.36 10.0 3.18 10.9 218 57
45 24.8 21.9 2.33 9.8 3.11 10.6 214 55
40 23.0 20.3 2.28 9.3 2.96 10.1 206 51
Outdoor Ambient Temperature 35 30 25 20 17 21.2 23.7 21.8 20.1 19.0 18.7 20.9 19.3 17.7 16.7 2.23 2.00 1.95 1.90 1.87 8.8 8.5 8.1 7.7 7.6 2.79 3.47 3.28 3.09 2.97 9.5 11.8 11.2 10.6 10.1 198 189 181 174 170 45 41 36 32 30
15 18.3 16.1 1.86 7.5 2.89 9.9 166 29
10 16.4 14.5 1.81 7.1 2.66 9.1 160 24
5 14.5 12.8 1.76 6.7 2.42 8.3 154 21
0 12.7 11.2 1.71 6.3 2.17 7.4 148 18
-5 10.8 9.5 1.66 5.9 1.90 6.5 142 15
-10 8.9 7.8 1.62 5.3 1.61 5.5 137 12
60 38.1 27.7 2.84 12.1 3.92 13.4 221 74
55 35.8 26.0 2.79 11.3 3.76 12.9 212 70
50 33.5 24.3 2.73 10.7 3.59 12.3 203 64
47 32.0 23.2 2.70 10.3 3.46 11.8 198 60
45 31.0 22.5 2.68 10.1 3.39 11.6 194 58
40 28.8 20.9 2.63 9.5 3.21 11.0 187 54
Outdoor Ambient Temperature 35 30 25 20 17 26.6 19.9 18.4 16.9 16.0 19.3 14.5 13.4 12.3 11.6 2.58 2.42 2.37 2.32 2.29 9.1 8.7 8.3 7.9 7.7 3.02 2.41 2.27 2.14 2.05 10.3 8.2 7.8 7.3 7.0 179 172 164 158 154 48 43 38 34 31
15 15.4 11.2 2.27 7.6 1.99 6.8 151 30
10 13.8 10.0 2.22 7.3 1.82 6.2 145 26
5 12.3 8.9 2.17 6.8 1.65 5.7 140 22
0 10.7 7.8 2.12 6.4 1.48 5.0 134 19
-5 9.1 6.6 2.07 5.9 1.29 4.4 129 16
-10 7.5 5.4 2.02 5.4 1.08 3.7 125 13
60 46.4 28.6 3.52 15.5 3.86 13.2 227 70
55 43.7 27.0 3.46 14.5 3.70 12.6 218 65
50 40.8 25.2 3.39 13.6 3.53 12.1 209 60
47 39.0 24.1 3.35 13.1 3.41 11.6 204 57
45 37.8 23.3 3.32 12.9 3.33 11.4 200 54
40 35.1 21.7 3.26 12.1 3.15 10.8 192 50
Outdoor Ambient Temperature 35 30 25 20 17 32.4 28.7 26.5 24.4 23.0 20.0 17.7 16.3 15.0 14.2 3.19 3.08 3.01 2.95 2.91 11.5 11.0 10.5 10.0 9.8 2.97 2.72 2.57 2.42 2.31 10.1 9.3 8.8 8.3 7.9 184 177 169 162 158 45 40 36 32 29
15 22.1 13.7 2.88 9.7 2.25 7.7 155 28
10 19.9 12.3 2.82 9.2 2.06 7.1 149 24
5 17.6 10.9 2.75 8.6 1.87 6.4 144 21
0 15.4 9.5 2.69 8.1 1.67 5.7 138 17
-5 13.1 8.1 2.62 7.4 1.46 5.0 133 15
-10 10.7 6.6 2.56 6.7 1.23 4.2 128 12
60 51.2 29.6 3.77 16.8 3.98 13.6 215 69
55 48.2 27.9 3.70 15.7 3.81 13.0 207 64
50 45.0 26.1 3.63 14.8 3.63 12.4 198 59
47 43.0 24.9 3.59 14.3 3.51 12.0 193 56
45 41.7 24.1 3.56 14.0 3.43 11.7 189 54
40 38.7 22.4 3.49 13.2 3.24 11.1 182 49
Outdoor Ambient Temperature 35 30 25 20 17 35.7 33.6 31.1 28.6 27.0 20.7 19.5 18.0 16.5 15.6 3.42 3.34 3.27 3.20 3.16 12.5 12.0 11.5 10.9 10.7 3.05 2.95 2.78 2.62 2.50 10.4 10.1 9.5 8.9 8.5 175 167 160 154 150 44 40 35 31 29
15 26.0 15.0 3.13 10.5 2.43 8.3 147 28
10 23.3 13.5 3.06 10.0 2.23 7.6 142 24
5 20.7 12.0 3.00 9.3 2.02 6.9 136 20
0 18.0 10.4 2.93 8.8 1.80 6.2 131 17
-5 15.4 8.9 2.86 8.1 1.58 5.4 126 15
-10 12.6 7.3 2.79 7.3 1.32 4.5 121 12
60 66.0 34.0 4.95 21.0 3.91 13.4 244 70
55 62.2 32.0 4.85 19.6 3.75 12.8 235 65
50 58.1 29.9 4.75 18.4 3.58 12.2 225 60
47 55.5 28.5 4.70 17.8 3.46 11.8 219 57
45 53.8 27.7 4.66 17.4 3.38 11.5 215 54
40 50.0 25.7 4.57 16.4 3.20 10.9 207 50
Outdoor Ambient Temperature 35 30 25 20 17 46.1 43.6 40.3 37.1 35.0 23.7 22.4 20.7 19.1 18.0 4.47 4.30 4.21 4.11 4.06 15.6 14.9 14.2 13.5 13.2 3.02 2.97 2.80 2.64 2.52 10.3 10.1 9.6 9.0 8.6 198 190 182 174 170 45 40 36 32 29
15 33.7 17.3 4.02 13.0 2.45 8.4 167 28
10 30.2 15.6 3.93 12.4 2.25 7.7 161 24
5 26.8 13.8 3.84 11.5 2.05 7.0 155 21
0 23.4 12.0 3.75 10.8 1.83 6.2 148 17
-5 20.0 10.3 3.65 10.0 1.60 5.5 143 15
-10 16.3 8.4 3.56 9.0 1.34 4.6 138 12
VSH130361A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 40.2 29.2 2.90 13.0 4.07 13.9 230 80
VSH130421A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 49.0 30.3 3.59 16.7 4.00 13.7 237 75
VSH130481A*
MBh ∆T kW Amps COP EER HI PR LO PR
65 54.1 31.3 3.84 18.1 4.12 14.1 224 74
VSH130601A*
MBh ∆T KW AMPS COP EER HI PR LO PR
65 69.8 35.9 5.04 22.7 4.05 13.8 255 75
High pressure is measured at the suction service valve ( the larger valve). Low pressure is measured at the gauge port connection. Calculations are based on nominal CFM and 70 °F indoor dry bulb.
SS-VSH13
www.goodmanmfg.com
Amps = Outdoor unit amps (comp.+fan) kW = Total system power
5
6
www.goodmanmfg.com
59 17.6 0.74 18 1.26 4.8 137 63 17.1 0.70 18 1.26 4.8 136 62 15.8 0.68 19 1.23 4.6 132 60
17.94 0.84 20 1.27 4.8 138 63 17.4 0.80 21 1.27 4.8 137 63 16.1 0.77 22 1.24 4.7 133 61
Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T KW 525 AMPS HI PR LO PR
MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR
18.47 0.75 19 1.30 4.9 149 67 17.9 0.71 20 1.29 4.9 147 67 16.5 0.69 20 1.26 4.8 143 65
63 18.3 0.62 15 1.29 4.9 147 67 17.7 0.59 16 1.28 4.9 146 66 16.4 0.57 16 1.25 4.7 142 64
19.99 0.57 15 1.34 5.1 157 74 19.4 0.54 16 1.33 5.1 156 73 17.9 0.52 16 1.30 4.9 151 71
67 20.0 0.43 12 1.33 5.1 156 73 19.4 0.41 12 1.32 5.0 154 72 17.9 0.39 12 1.29 4.9 150 70 21.45 0.36 11 1.38 5.3 164 78 20.8 0.35 11 1.37 5.2 162 78 19.2 0.34 11 1.34 5.1 158 75
71 17.52 0.87 21 1.37 5.2 155 67 17.0 0.83 22 1.36 5.2 154 66 15.7 0.80 22 1.33 5.0 149 64
59 17.2 0.76 18 1.36 5.2 154 66 16.7 0.73 19 1.35 5.1 152 66 15.4 0.70 19 1.32 5.0 148 64 18.04 0.78 19 1.40 5.3 167 71 17.5 0.74 20 1.39 5.3 166 70 16.2 0.71 20 1.35 5.1 161 68
63 17.9 0.64 16 1.39 5.3 165 70 17.3 0.61 16 1.38 5.2 164 70 16.0 0.59 16 1.34 5.1 159 68 19.53 0.59 16 1.44 5.5 177 78 19.0 0.56 16 1.43 5.5 175 77 17.5 0.54 17 1.40 5.3 170 75
67 19.6 0.44 12 1.43 5.5 175 77 19.0 0.42 12 1.42 5.4 173 76 17.5 0.41 12 1.38 5.3 168 74
75ºF
20.96 0.38 11 1.49 5.7 184 83 20.3 0.36 11 1.47 5.7 182 82 18.8 0.35 11 1.44 5.5 177 79
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
17.10 0.89 21 1.45 5.7 177 70 16.6 0.85 22 1.44 5.6 175 69 15.3 0.82 22 1.41 5.5 170 67
59 16.8 0.78 18 1.44 5.6 175 69 16.3 0.75 19 1.43 5.6 173 68 15.1 0.72 19 1.40 5.4 168 66 19.06 0.60 16 1.53 6.0 201 81 18.5 0.57 16 1.52 5.9 199 80 17.1 0.55 17 1.48 5.8 193 78
20.46 0.39 11 1.58 6.2 209 86 19.9 0.37 11 1.57 6.1 207 85 18.3 0.36 11 1.53 6.0 201 83
16.69 0.92 21 1.53 6.0 201 73 16.2 0.88 22 1.51 6.0 199 72 15.0 0.84 22 1.48 5.8 193 70
17.18 0.82 19 1.56 6.2 217 78 16.7 0.78 20 1.55 6.1 214 77 15.40 0.76 20 1.51 6.0 208 75
18.60 0.62 16 1.61 6.4 229 85 18.1 0.59 16 1.59 6.3 226 84 16.7 0.57 17 1.56 6.2 220 81
19.96 0.40 11 1.66 6.6 238 90 19.4 0.38 11 1.65 6.6 236 89 17.9 0.37 12 1.61 6.4 229 87
71 15.85 0.95 21 1.59 6.4 226 77 15.4 0.91 21 1.58 6.4 224 76 14.2 0.88 22 1.54 6.2 217 73
59 15.6 0.84 18 1.57 6.4 224 76 15.1 0.80 19 1.56 6.3 222 75 14.0 0.77 19 1.52 6.1 215 73 16.32 0.85 19 1.62 6.6 244 81 15.8 0.81 20 1.61 6.5 241 81 14.6 0.78 20 1.57 6.3 234 78
63 16.2 0.70 15 1.61 6.5 241 81 15.7 0.67 16 1.60 6.4 239 80 14.5 0.64 16 1.56 6.3 232 77 17.67 0.65 16 1.67 6.8 257 89 17.2 0.62 16 1.66 6.7 255 88 15.8 0.59 16 1.62 6.5 247 85
67 17.7 0.49 12 1.66 6.7 255 88 17.2 0.46 12 1.65 6.7 252 87 15.9 0.45 12 1.61 6.5 245 84
105ºF
18.96 0.42 11 1.73 7.0 268 95 18.4 0.40 11 1.71 7.0 266 94 17.0 0.38 11 1.67 6.8 258 91
71 14.68 0.96 19 1.64 6.8 250 79 14.3 0.92 20 1.63 6.7 248 78 13.2 0.88 20 1.59 6.5 240 76
59 14.4 0.85 17 1.63 6.7 248 78 14.0 0.81 17 1.61 6.7 245 78 12.9 0.78 18 1.58 6.5 238 75 15.12 0.86 18 1.68 7.0 269 84 14.7 0.82 18 1.66 6.9 266 83 13.5 0.79 19 1.62 6.7 258 81
63 15.0 0.71 14 1.66 6.9 266 83 14.5 0.67 15 1.65 6.8 264 83 13.4 0.65 15 1.61 6.6 256 80 16.36 0.65 15 1.73 7.2 284 92 15.9 0.62 15 1.72 7.1 281 91 14.7 0.60 15 1.68 6.9 273 88
67 16.4 0.49 11 1.72 7.1 281 91 15.9 0.47 11 1.70 7.1 279 90 14.7 0.45 12 1.66 6.9 270 87
115ºF
17.56 0.42 10 1.79 7.5 296 98 17.1 0.40 10 1.77 7.4 293 97 15.7 0.38 11 1.73 7.2 285 94
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
17.61 0.80 19 1.48 5.8 190 74 17.1 0.76 20 1.47 5.7 188 73 15.8 0.73 20 1.44 5.6 183 71
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 63 67 71 59 63 67 17.4 19.1 16.4 17.0 18.6 0.65 0.45 0.81 0.67 0.47 16 12 18 16 12 1.47 1.52 1.51 1.55 1.59 5.7 5.9 6.0 6.1 6.3 188 199 199 214 226 73 80 72 77 84 16.9 18.5 15.9 16.5 18.1 0.62 0.43 0.77 0.64 0.45 16 12 19 16 12 1.46 1.50 1.50 1.53 1.58 5.7 5.9 5.9 6.1 6.3 186 197 197 212 224 72 79 72 76 83 15.6 17.1 14.7 15.2 16.7 0.60 0.42 0.74 0.62 0.43 16 12 19 17 13 1.42 1.47 1.47 1.50 1.54 5.5 5.7 5.8 5.9 6.1 181 191 191 206 217 70 77 69 74 81
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130181A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 18.26 0.92 23 1.28 4.9 140 64 17.7 0.88 24 1.27 4.8 138 63 16.4 0.84 24 1.25 4.7 134 61
18.58 0.96 24 1.29 4.9 141 65 18.0 0.92 25 1.28 4.9 140 64 16.6 0.89 26 1.26 4.7 136 62
Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR
MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR
18.93 0.93 24 1.32 5.0 152 69 18.4 0.89 25 1.31 5.0 150 68 17.0 0.85 25 1.28 4.9 146 66
63 18.65 0.86 22 1.31 5.0 150 68 18.1 0.82 23 1.30 4.9 149 67 16.7 0.79 23 1.27 4.8 145 65
19.83 0.84 23 1.36 5.2 160 75 19.3 0.80 24 1.35 5.2 159 74 17.8 0.77 24 1.32 5.0 154 72
67 19.93 0.70 19 1.35 5.2 159 74 19.4 0.67 20 1.34 5.1 157 74 17.9 0.64 20 1.31 5.0 153 71 21.16 0.68 20 1.40 5.4 167 80 20.5 0.65 20 1.39 5.3 166 79 19.0 0.63 21 1.36 5.2 161 77
71 21.31 0.52 15 1.39 5.3 166 79 20.7 0.50 16 1.38 5.3 164 78 19.1 0.48 16 1.35 5.1 159 76 18.14 1.00 25 1.39 5.3 158 68 17.6 0.95 26 1.38 5.3 157 68 16.3 0.92 26 1.35 5.1 152 66
59 17.83 0.95 23 1.38 5.3 157 68 17.3 0.91 24 1.37 5.2 155 67 16.0 0.88 24 1.34 5.1 151 65 18.49 0.96 24 1.42 5.4 171 73 18.0 0.92 25 1.41 5.4 169 72 16.6 0.89 26 1.38 5.2 164 70
63 18.22 0.89 22 1.41 5.4 169 72 17.7 0.85 23 1.40 5.3 167 71 16.3 0.82 23 1.36 5.2 162 69 19.37 0.87 23 1.46 5.6 180 79 18.8 0.83 24 1.45 5.6 178 78 17.4 0.80 24 1.42 5.4 173 76
67 19.47 0.73 19 1.45 5.6 178 78 18.9 0.69 20 1.44 5.5 177 78 17.4 0.67 20 1.41 5.4 171 75
75ºF
20.66 0.70 20 1.51 5.8 188 84 20.1 0.67 21 1.50 5.8 186 84 18.5 0.65 21 1.46 5.6 180 81
71 20.81 0.54 15 1.50 5.8 186 84 20.2 0.52 16 1.49 5.7 184 83 18.6 0.50 16 1.45 5.6 179 80
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
17.71 1.00 24 1.48 5.8 180 71 17.2 0.98 26 1.46 5.7 178 70 15.9 0.94 26 1.43 5.6 173 68
18.05 0.99 24 1.51 5.9 194 75 17.5 0.94 25 1.49 5.8 192 75 16.2 0.91 26 1.46 5.7 186 72
20.17 0.72 20 1.60 6.3 214 88 19.6 0.69 21 1.59 6.3 211 87 18.1 0.66 21 1.55 6.1 205 84
17.28 1.00 24 1.55 6.1 205 74 16.8 1.00 26 1.54 6.1 203 74 15.5 0.97 26 1.50 5.9 197 72
17.61 1.00 24 1.58 6.3 221 79 17.1 0.97 25 1.57 6.2 219 78 15.8 0.94 26 1.53 6.1 212 76
18.45 0.92 23 1.63 6.5 233 87 17.9 0.88 24 1.62 6.4 231 86 16.5 0.85 24 1.58 6.3 224 83
19.68 0.75 20 1.69 6.7 243 92 19.1 0.71 21 1.67 6.7 241 91 17.6 0.69 21 1.63 6.5 234 88
16.42 1.00 22 1.61 6.5 231 78 15.9 1.00 24 1.60 6.5 229 77 14.7 1.00 26 1.56 6.3 222 75
59 16.13 1.00 22 1.60 6.5 229 77 15.7 1.00 24 1.59 6.4 226 77 14.5 0.96 24 1.55 6.2 220 74 16.73 1.00 23 1.65 6.7 249 83 16.2 1.00 25 1.64 6.6 246 82 15.0 0.97 26 1.60 6.4 239 80
63 16.49 1.00 22 1.64 6.6 246 82 16.0 0.94 23 1.62 6.6 244 81 14.8 0.90 23 1.58 6.4 236 79 17.52 0.95 23 1.70 6.9 262 91 17.0 0.91 24 1.69 6.8 260 90 15.7 0.88 24 1.65 6.7 252 87
67 17.61 0.80 19 1.69 6.8 260 90 17.1 0.76 20 1.67 6.8 257 89 15.8 0.73 20 1.63 6.6 250 86
105ºF
18.70 0.77 20 1.76 7.2 274 97 18.2 0.74 21 1.74 7.1 271 96 16.8 0.71 21 1.70 6.9 263 93
71 18.83 0.60 15 1.74 7.1 271 96 18.3 0.57 16 1.73 7.0 268 95 16.9 0.55 16 1.69 6.8 260 92 15.21 1.00 21 1.67 6.9 255 81 14.8 1.00 23 1.66 6.9 253 80 13.6 1.00 24 1.61 6.7 245 78
59 14.94 1.00 20 1.66 6.9 253 80 14.5 1.00 22 1.64 6.8 250 79 13.4 0.97 23 1.60 6.6 243 77 15.50 1.00 21 1.71 7.1 275 86 15.0 1.00 23 1.69 7.0 272 85 13.9 0.98 24 1.65 6.8 264 83
63 15.27 1.00 21 1.69 7.0 272 85 14.8 0.94 21 1.68 7.0 269 84 13.7 0.91 22 1.64 6.8 261 82 16.23 0.96 21 1.76 7.3 290 94 15.8 0.92 22 1.75 7.2 287 93 14.5 0.89 23 1.70 7.0 278 90
67 16.32 0.80 18 1.75 7.2 287 93 15.8 0.77 19 1.73 7.2 284 92 14.6 0.74 19 1.69 7.0 276 89
115ºF
17.32 0.78 18 1.82 7.6 302 100 16.8 0.74 19 1.80 7.5 299 99 15.5 0.72 20 1.76 7.3 290 96
71 17.44 0.60 14 1.80 7.5 299 99 16.9 0.57 15 1.79 7.5 296 98 15.6 0.55 15 1.74 7.2 288 95
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
18.91 0.89 23 1.55 6.1 205 82 18.4 0.85 24 1.54 6.0 203 82 16.9 0.82 24 1.50 5.9 197 79
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 17.41 17.79 19.00 20.31 16.98 17.35 18.54 19.82 1.00 0.92 0.74 0.56 1.00 0.94 0.77 0.57 24 22 19 15 23 22 19 16 1.46 1.49 1.54 1.59 1.54 1.57 1.62 1.67 5.7 5.8 6.0 6.3 6.1 6.2 6.4 6.7 178 192 203 211 203 219 231 241 70 75 82 87 74 78 86 91 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 24 23 20 16 24 23 20 16 1.45 1.48 1.53 1.58 1.53 1.56 1.61 1.66 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6 177 190 201 209 201 217 229 239 70 74 81 86 73 78 85 90 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.53 25 23 20 16 25 24 21 16 1.42 1.45 1.49 1.54 1.49 1.52 1.57 1.62 5.5 5.6 5.8 6.0 5.9 6.0 6.2 6.4 171 184 195 203 195 210 222 231 67 72 78 83 71 75 82 88
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130181A*** (CONT.)
7
8
www.goodmanmfg.com
59 17.6 0.74 18 1.25 4.0 136 61 17.1 0.70 18 1.24 4.0 135 61 15.8 0.68 19 1.22 3.9 131 59
17.94 0.84 20 1.26 4.1 137 62 17.4 0.80 21 1.25 4.0 136 61 16.1 0.77 22 1.22 3.9 132 59
Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T 600 kW Amps HI PR LO PR MBh S/T ∆T KW 525 AMPS HI PR LO PR
MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T KW 525 AMPS HI PR LO PR
18.47 0.75 19 1.28 4.1 148 66 17.9 0.71 20 1.27 4.1 146 65 16.5 0.69 20 1.25 4.0 142 63
63 18.3 0.61 15 1.27 4.1 146 65 17.7 0.59 16 1.26 4.1 145 64 16.4 0.57 16 1.24 4.0 141 62
19.99 0.57 15 1.32 4.3 156 72 19.4 0.54 16 1.31 4.2 155 71 17.9 0.52 16 1.28 4.1 150 69
67 20.0 0.43 12 1.31 4.2 155 71 19.4 0.41 12 1.30 4.2 153 70 17.9 0.39 12 1.27 4.1 148 68 21.45 0.36 11 1.36 4.4 163 76 20.8 0.35 11 1.35 4.4 161 76 19.2 0.34 11 1.32 4.3 156 73
71 17.52 0.87 21 1.34 4.3 154 65 17.0 0.83 22 1.33 4.3 153 65 15.7 0.80 22 1.31 4.2 148 63
59 17.2 0.76 18 1.33 4.3 153 65 16.7 0.73 19 1.32 4.3 151 64 15.4 0.70 19 1.30 4.2 147 62 18.04 0.78 19 1.37 4.4 166 69 17.5 0.74 20 1.36 4.4 164 69 16.2 0.71 20 1.33 4.3 159 67
63 17.9 0.64 15 1.36 4.4 164 69 17.3 0.61 16 1.35 4.4 163 68 16.0 0.59 16 1.32 4.3 158 66 19.53 0.59 16 1.41 4.6 175 76 19.0 0.56 16 1.40 4.5 173 75 17.5 0.54 17 1.37 4.4 168 73
67 19.6 0.44 12 1.40 4.5 173 75 19.0 0.42 12 1.39 4.5 172 74 17.5 0.41 12 1.36 4.4 167 72
75ºF
20.96 0.38 11 1.45 4.7 183 81 20.3 0.36 11 1.44 4.7 181 80 18.8 0.35 11 1.41 4.5 176 77
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
17.10 0.89 21 1.42 4.7 175 68 16.6 0.85 22 1.41 4.6 174 67 15.3 0.82 22 1.38 4.5 168 65
19.06 0.60 16 1.49 4.9 199 79 18.5 0.57 16 1.48 4.9 197 78 17.1 0.55 17 1.45 4.7 191 76
20.46 0.39 11 1.53 5.1 208 84 19.9 0.37 11 1.52 5.0 206 83 18.3 0.36 11 1.49 4.9 200 81
16.69 0.92 21 1.49 4.9 200 71 16.2 0.88 22 1.47 4.9 198 71 15.0 0.84 22 1.44 4.8 192 68
17.18 0.82 19 1.52 5.0 215 76 16.7 0.78 20 1.50 5.0 213 75 15.40 0.76 20 1.47 4.9 206 73
18.60 0.62 16 1.56 5.2 227 83 18.1 0.59 16 1.55 5.2 225 82 16.7 0.57 17 1.51 5.0 218 79
19.96 0.40 11 1.61 5.4 237 88 19.4 0.38 11 1.60 5.3 234 87 17.9 0.37 12 1.56 5.2 227 85
71 15.85 0.95 21 1.54 5.2 225 75 15.4 0.91 21 1.53 5.2 222 74 14.2 0.88 22 1.50 5.0 216 72
59 15.6 0.84 18 1.53 5.2 222 74 15.1 0.80 19 1.52 5.1 220 73 14.0 0.77 19 1.48 5.0 214 71 16.32 0.85 19 1.57 5.3 242 79 15.8 0.81 20 1.56 5.3 239 79 14.6 0.78 20 1.53 5.2 232 76
63 16.2 0.70 15 1.56 5.3 239 79 15.7 0.67 16 1.55 5.2 237 78 14.5 0.64 16 1.51 5.1 230 75 17.67 0.65 16 1.62 5.5 255 87 17.2 0.62 16 1.61 5.4 253 86 15.8 0.59 16 1.57 5.3 245 83
67 17.7 0.48 12 1.61 5.4 253 86 17.2 0.46 12 1.60 5.4 250 85 15.9 0.45 12 1.56 5.3 243 82
105ºF
18.96 0.41 11 1.67 5.7 266 92 18.4 0.40 11 1.66 5.6 264 91 17.0 0.38 11 1.62 5.5 256 89
71 14.68 0.96 19 1.59 5.5 248 77 14.3 0.92 20 1.58 5.5 246 76 13.2 0.88 20 1.54 5.3 238 74
59 14.4 0.85 17 1.58 5.4 246 76 14.0 0.81 17 1.57 5.4 243 76 12.9 0.78 18 1.53 5.3 236 73 15.12 0.86 18 1.62 5.6 267 82 14.7 0.82 18 1.61 5.6 265 81 13.5 0.79 19 1.57 5.4 257 79
63 15.0 0.71 14 1.61 5.6 264 81 14.5 0.67 15 1.60 5.5 262 80 13.4 0.65 15 1.56 5.4 254 78 16.36 0.65 14 1.67 5.8 282 90 15.9 0.62 15 1.66 5.7 279 89 14.7 0.60 15 1.62 5.6 271 86
67 16.4 0.49 11 1.66 5.7 279 89 15.9 0.47 11 1.65 5.7 277 88 14.7 0.45 12 1.61 5.5 268 85
115ºF
17.56 0.42 10 1.72 6.0 294 95 17.1 0.40 10 1.71 5.9 291 95 15.7 0.38 11 1.67 5.8 283 92
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
17.61 0.80 19 1.45 4.8 189 72 17.1 0.76 20 1.44 4.7 187 71 15.8 0.73 20 1.40 4.6 181 69
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 16.8 17.4 19.1 16.4 17.0 18.6 0.78 0.65 0.45 0.81 0.67 0.47 18 16 12 18 16 12 1.41 1.44 1.48 1.47 1.50 1.55 4.6 4.7 4.9 4.9 5.0 5.2 174 187 197 198 213 225 67 71 78 70 75 82 16.3 16.9 18.5 15.9 16.5 18.1 0.75 0.62 0.43 0.77 0.64 0.45 19 16 12 19 16 12 1.40 1.43 1.47 1.46 1.49 1.54 4.6 4.7 4.8 4.9 5.0 5.1 172 185 195 196 211 222 66 71 77 70 74 81 15.1 15.6 17.1 14.7 15.2 16.7 0.72 0.60 0.42 0.74 0.62 0.43 19 16 12 19 17 13 1.37 1.39 1.43 1.43 1.46 1.50 4.5 4.6 4.7 4.7 4.8 5.0 167 179 189 190 204 216 64 69 75 68 72 79
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130191A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 18.26 0.92 23 1.27 4.1 139 62 17.7 0.88 24 1.26 4.1 137 62 16.4 0.84 24 1.23 4.0 133 60
18.58 0.96 24 1.28 4.1 140 63 18.0 0.92 25 1.27 4.1 139 62 16.6 0.88 26 1.24 4.0 135 60
Airflow MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR
MBh S/T ∆T kW 675 Amps HI PR LO PR MBh S/T ∆T kW 600 Amps HI PR LO PR MBh S/T ∆T kW 525 Amps HI PR LO PR
18.93 0.93 24 1.30 4.2 151 67 18.4 0.89 25 1.29 4.2 149 66 17.0 0.85 25 1.26 4.1 145 64
63 18.65 0.86 22 1.29 4.2 149 66 18.1 0.82 23 1.28 4.1 148 66 16.7 0.79 23 1.25 4.0 143 64
19.83 0.84 23 1.34 4.3 159 73 19.3 0.80 24 1.33 4.3 158 72 17.8 0.77 24 1.30 4.2 153 70
67 19.93 0.70 19 1.33 4.3 158 72 19.4 0.67 20 1.32 4.3 156 72 17.9 0.64 20 1.29 4.2 151 70 21.16 0.68 20 1.38 4.5 166 78 20.5 0.65 20 1.37 4.4 165 77 19.0 0.63 21 1.34 4.3 160 75
71 21.31 0.52 15 1.37 4.4 165 77 20.7 0.50 16 1.36 4.4 163 76 19.1 0.48 16 1.33 4.3 158 74 18.14 1.00 25 1.36 4.4 157 67 17.6 0.95 26 1.35 4.4 156 66 16.3 0.92 26 1.32 4.3 151 64
59 17.83 0.95 23 1.35 4.4 156 66 17.3 0.91 24 1.34 4.3 154 65 16.0 0.87 24 1.31 4.2 150 63 18.49 0.96 24 1.39 4.5 169 71 18.0 0.92 25 1.38 4.5 168 70 16.6 0.88 26 1.35 4.4 163 68
63 18.22 0.89 22 1.38 4.5 168 70 17.7 0.85 23 1.37 4.4 166 69 16.3 0.82 23 1.34 4.3 161 67 19.37 0.87 23 1.43 4.6 179 77 18.8 0.83 24 1.42 4.6 177 77 17.4 0.80 24 1.39 4.5 172 74
67 19.47 0.73 19 1.42 4.6 177 77 18.9 0.69 20 1.41 4.6 175 76 17.4 0.67 20 1.38 4.4 170 73
75ºF
20.66 0.70 20 1.47 4.8 186 82 20.1 0.67 21 1.46 4.7 185 81 18.5 0.65 21 1.43 4.6 179 79
71 20.81 0.54 15 1.46 4.7 185 81 20.2 0.52 16 1.45 4.7 183 81 18.6 0.50 16 1.42 4.6 177 78
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
17.71 1.00 24 1.44 4.7 179 69 17.2 0.98 26 1.43 4.7 177 68 15.9 0.94 26 1.40 4.6 172 66
18.05 0.99 24 1.47 4.8 193 74 17.5 0.94 25 1.46 4.8 191 73 16.2 0.91 26 1.43 4.7 185 71
20.17 0.72 20 1.56 5.1 212 86 19.6 0.69 21 1.55 5.1 210 85 18.1 0.66 21 1.51 5.0 204 82
17.28 1.00 24 1.51 5.0 204 73 16.8 1.00 26 1.50 5.0 202 72 15.5 0.97 26 1.46 4.9 196 70
17.61 1.00 24 1.54 5.1 219 77 17.1 0.97 25 1.53 5.1 217 77 15.8 0.94 26 1.49 5.0 211 74
18.45 0.92 23 1.58 5.3 232 84 17.9 0.88 24 1.57 5.2 229 84 16.5 0.85 24 1.54 5.1 222 81
19.68 0.75 20 1.63 5.5 242 90 19.1 0.71 21 1.62 5.4 239 89 17.6 0.69 21 1.58 5.3 232 86
16.42 1.00 22 1.57 5.3 229 76 15.9 1.00 24 1.55 5.3 227 75 14.7 1.00 26 1.52 5.1 220 73
59 16.13 1.00 22 1.55 5.3 227 75 15.7 1.00 24 1.54 5.2 225 75 14.5 0.96 24 1.51 5.1 218 72 16.73 1.00 23 1.60 5.4 247 81 16.2 1.00 25 1.59 5.4 244 80 15.0 0.97 26 1.55 5.2 237 78
63 16.49 1.00 22 1.59 5.4 244 80 16.0 0.93 23 1.57 5.3 242 79 14.8 0.90 23 1.54 5.2 235 77 17.52 0.95 23 1.65 5.6 260 88 17.0 0.91 24 1.63 5.5 258 88 15.7 0.88 24 1.60 5.4 250 85
67 17.61 0.80 19 1.63 5.5 258 88 17.1 0.76 20 1.62 5.5 255 87 15.8 0.73 20 1.58 5.4 248 84
105ºF
18.70 0.77 20 1.70 5.8 272 94 18.2 0.74 21 1.68 5.7 269 93 16.8 0.71 21 1.64 5.6 261 90
71 18.83 0.60 15 1.68 5.7 269 93 18.3 0.57 16 1.67 5.7 266 92 16.9 0.55 16 1.63 5.5 258 90 15.21 1.00 21 1.62 5.6 253 79 14.8 1.00 23 1.60 5.5 251 78 13.6 1.00 24 1.57 5.4 243 76
59 14.94 1.00 20 1.60 5.5 251 78 14.5 1.00 22 1.59 5.5 248 77 13.4 0.97 23 1.55 5.4 241 75 15.50 1.00 21 1.65 5.7 273 84 15.0 1.00 23 1.64 5.7 270 83 13.9 0.98 24 1.60 5.5 262 80
63 15.27 1.00 21 1.64 5.7 270 83 14.8 0.94 21 1.62 5.6 267 82 13.7 0.91 22 1.59 5.5 259 80 16.23 0.96 21 1.70 5.9 288 91 15.8 0.92 22 1.69 5.8 285 91 14.5 0.88 23 1.65 5.7 276 88
67 16.32 0.80 18 1.69 5.8 285 91 15.8 0.77 19 1.67 5.8 282 90 14.6 0.74 19 1.63 5.6 274 87
115ºF
17.32 0.78 18 1.75 6.1 300 97 16.8 0.74 19 1.74 6.0 297 96 15.5 0.72 20 1.70 5.9 288 94
71 17.44 0.60 14 1.74 6.0 297 96 16.9 0.57 15 1.72 6.0 294 95 15.6 0.55 15 1.68 5.8 285 93
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
18.91 0.89 23 1.51 5.0 203 80 18.4 0.85 24 1.50 4.9 201 80 16.9 0.82 24 1.47 4.8 195 77
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 17.41 17.79 19.00 20.31 16.98 17.35 18.54 19.82 1.00 0.91 0.74 0.56 1.00 0.94 0.77 0.57 24 22 19 15 23 22 19 16 1.43 1.46 1.50 1.55 1.50 1.53 1.57 1.62 4.7 4.8 4.9 5.1 5.0 5.1 5.2 5.4 177 191 201 210 202 217 229 239 68 73 80 85 72 77 84 89 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 24 23 20 16 24 23 20 16 1.42 1.45 1.49 1.53 1.49 1.52 1.56 1.61 4.7 4.8 4.9 5.1 4.9 5.0 5.2 5.4 175 189 199 208 200 215 227 237 68 72 79 84 71 76 83 88 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 0.90 0.84 0.68 0.51 0.93 0.87 0.71 0.53 25 23 20 16 25 24 21 16 1.39 1.41 1.46 1.50 1.45 1.48 1.52 1.57 4.5 4.6 4.8 4.9 4.8 4.9 5.1 5.2 170 183 193 202 194 209 220 230 66 70 76 81 69 73 80 85
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130191A*** (CONT.)
9
10
www.goodmanmfg.com
59 22.5 0.74 17 1.64 6.1 137 61 21.9 0.71 17 1.62 6.1 136 60 20.2 0.68 18 1.59 5.9 132 59
22.92 0.84 19 1.65 6.2 139 62 22.3 0.80 20 1.64 6.1 137 61 20.5 0.78 20 1.60 6.0 133 59
Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T 820 kW Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR
MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR
23.60 0.75 18 1.68 6.3 149 66 22.9 0.72 18 1.67 6.3 148 65 21.1 0.69 19 1.63 6.1 143 63
63 23.4 0.62 14 1.67 6.3 148 65 22.7 0.59 15 1.66 6.2 146 64 20.9 0.57 15 1.62 6.1 142 62
25.54 0.57 15 1.73 6.5 158 72 24.8 0.54 15 1.72 6.5 156 71 22.9 0.53 15 1.68 6.3 151 69
67 25.6 0.43 11 1.72 6.5 156 71 24.8 0.41 11 1.71 6.4 154 70 22.9 0.40 12 1.67 6.2 150 68 27.41 0.37 10 1.79 6.8 164 76 26.6 0.35 10 1.77 6.7 163 75 24.6 0.34 11 1.73 6.5 158 73
71 22.39 0.87 20 1.77 6.7 156 65 21.7 0.83 20 1.76 6.6 154 64 20.1 0.80 21 1.72 6.4 149 63
59 22.0 0.77 17 1.76 6.6 154 64 21.4 0.73 18 1.74 6.6 153 64 19.7 0.71 18 1.70 6.4 148 62 23.05 0.78 18 1.81 6.8 167 69 22.4 0.75 19 1.79 6.8 166 69 20.7 0.72 19 1.75 6.6 161 67
63 22.8 0.64 15 1.79 6.8 166 69 22.2 0.61 15 1.78 6.7 164 68 20.4 0.59 15 1.74 6.5 159 66 24.95 0.59 15 1.86 7.1 177 76 24.2 0.56 15 1.85 7.0 175 75 22.4 0.54 16 1.80 6.8 170 73
67 25.0 0.45 11 1.85 7.0 175 75 24.3 0.42 12 1.83 6.9 173 74 22.4 0.41 12 1.79 6.7 168 72
75ºF
26.78 0.38 10 1.92 7.3 184 81 26.0 0.36 11 1.91 7.3 183 80 24.0 0.35 11 1.86 7.1 177 77
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
21.85 0.90 20 1.88 7.2 177 68 21.2 0.86 20 1.86 7.2 175 67 19.6 0.82 21 1.82 7.0 170 65
24.36 0.61 15 1.98 7.7 201 79 23.6 0.58 15 1.96 7.6 199 78 21.8 0.56 16 1.91 7.4 193 75
26.14 0.39 10 2.04 7.9 210 84 25.4 0.37 11 2.02 7.9 208 83 23.4 0.36 11 1.98 7.7 201 80
21.32 0.93 20 1.97 7.7 202 71 20.7 0.88 20 1.96 7.7 200 70 19.1 0.85 21 1.91 7.5 194 68
21.95 0.83 18 2.01 7.9 217 76 21.3 0.79 19 2.00 7.9 215 75 19.67 0.76 19 1.95 7.6 208 73
23.76 0.63 15 2.08 8.2 229 83 23.1 0.60 15 2.06 8.1 227 82 21.3 0.58 16 2.01 7.9 220 79
25.50 0.40 10 2.15 8.5 239 88 24.8 0.38 11 2.13 8.4 237 87 22.9 0.37 11 2.08 8.2 229 84
71 20.25 0.96 19 2.05 8.2 227 74 19.7 0.92 20 2.04 8.2 225 74 18.2 0.88 21 1.99 7.9 218 72
59 19.9 0.85 17 2.04 8.2 224 74 19.3 0.81 17 2.02 8.1 222 73 17.8 0.78 18 1.97 7.9 216 71 20.85 0.86 18 2.10 8.4 244 79 20.2 0.82 19 2.08 8.4 242 78 18.7 0.79 19 2.03 8.1 234 76
63 20.6 0.71 15 2.08 8.4 242 78 20.0 0.67 15 2.06 8.3 239 78 18.5 0.65 15 2.01 8.1 232 75 22.57 0.65 15 2.16 8.7 258 86 21.9 0.62 15 2.15 8.6 255 86 20.2 0.60 16 2.09 8.4 247 83
67 22.6 0.49 11 2.15 8.6 255 86 22.0 0.47 11 2.13 8.6 253 85 20.3 0.45 12 2.08 8.3 245 82
105ºF
24.23 0.42 10 2.24 9.0 269 92 23.5 0.40 11 2.22 9.0 266 91 21.7 0.38 11 2.16 8.7 258 88
71 18.76 0.97 18 2.12 8.7 251 77 18.2 0.92 19 2.10 8.6 248 76 16.8 0.89 19 2.05 8.4 241 74
59 18.4 0.85 16 2.10 8.6 248 76 17.9 0.81 16 2.09 8.6 246 75 16.5 0.78 17 2.04 8.3 238 73 19.32 0.87 17 2.17 8.9 270 82 18.8 0.83 17 2.15 8.8 267 81 17.3 0.80 18 2.10 8.6 259 79
63 19.1 0.71 14 2.15 8.8 267 81 18.6 0.68 14 2.13 8.8 264 80 17.1 0.65 14 2.08 8.5 256 78 20.91 0.66 14 2.24 9.2 285 89 20.3 0.63 14 2.22 9.1 282 89 18.7 0.60 14 2.17 8.9 273 86
67 21.0 0.49 10 2.22 9.1 282 89 20.3 0.47 11 2.20 9.1 279 88 18.8 0.45 11 2.15 8.8 271 85
115ºF
22.44 0.42 9 2.31 9.6 297 95 21.8 0.40 10 2.29 9.5 294 94 20.1 0.39 10 2.24 9.2 285 92
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
22.50 0.80 18 1.92 7.4 190 72 21.8 0.77 19 1.90 7.4 189 71 20.2 0.74 19 1.86 7.2 183 69
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 21.5 22.3 24.4 21.0 21.7 23.8 0.79 0.66 0.46 0.81 0.68 0.47 17 15 11 17 15 11 1.86 1.90 1.96 1.96 2.00 2.06 7.2 7.4 7.6 7.7 7.9 8.1 175 189 199 200 215 227 67 71 78 70 75 82 20.9 21.6 23.7 20.4 21.1 23.1 0.75 0.63 0.44 0.78 0.65 0.45 18 15 12 18 15 12 1.85 1.89 1.95 1.94 1.98 2.04 7.1 7.3 7.5 7.6 7.8 8.0 173 187 197 198 213 224 66 71 77 70 74 81 19.3 20.0 21.9 18.8 19.5 21.3 0.73 0.61 0.42 0.75 0.63 0.43 18 15 12 18 16 12 1.80 1.84 1.90 1.89 1.93 2.00 6.9 7.1 7.3 7.4 7.6 7.8 168 181 191 192 206 218 64 68 75 68 72 78
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130241A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 23.33 0.93 22 1.66 6.2 140 62 22.6 0.88 22 1.65 6.2 139 62 20.9 0.85 23 1.61 6.0 135 60
23.74 0.97 23 1.67 6.3 141 63 23.0 0.93 24 1.66 6.2 140 62 21.3 0.89 24 1.62 6.1 136 60
Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T 820 kW Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR
MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T 718 kW Amps HI PR LO PR
24.19 0.94 23 1.71 6.4 152 67 23.5 0.89 24 1.69 6.4 151 66 21.7 0.86 24 1.66 6.2 146 64
63 23.84 0.87 21 1.69 6.4 151 66 23.1 0.83 21 1.68 6.3 149 66 21.4 0.80 22 1.64 6.2 145 64
25.34 0.84 21 1.76 6.6 161 73 24.6 0.81 22 1.75 6.6 159 72 22.7 0.78 23 1.71 6.4 154 70
67 25.47 0.71 18 1.75 6.6 159 72 24.7 0.67 19 1.73 6.5 158 72 22.8 0.65 19 1.69 6.4 153 69 27.03 0.69 18 1.81 6.9 168 78 26.2 0.65 19 1.80 6.8 166 77 24.2 0.63 20 1.76 6.6 161 75
71 27.22 0.53 14 1.80 6.8 166 77 26.4 0.50 15 1.79 6.8 164 76 24.4 0.49 15 1.74 6.6 159 74 23.18 1.00 23 1.80 6.8 159 66 22.5 0.96 24 1.78 6.7 157 66 20.8 0.92 25 1.74 6.6 152 64
59 22.79 0.96 22 1.78 6.7 157 66 22.1 0.91 23 1.77 6.7 156 65 20.4 0.88 23 1.73 6.5 151 63 23.63 0.97 23 1.84 7.0 171 71 22.9 0.93 24 1.82 6.9 169 70 21.2 0.89 24 1.78 6.7 164 68
63 23.28 0.90 21 1.82 6.9 169 70 22.6 0.86 22 1.81 6.8 167 69 20.9 0.83 22 1.76 6.7 162 67 24.75 0.88 22 1.89 7.2 180 77 24.0 0.84 22 1.88 7.1 179 76 22.2 0.81 23 1.83 6.9 173 74
67 24.87 0.73 18 1.88 7.1 179 76 24.2 0.70 19 1.86 7.1 177 76 22.3 0.67 19 1.82 6.9 172 73
75ºF
26.40 0.71 19 1.95 7.5 188 82 25.6 0.68 19 1.94 7.4 186 81 23.7 0.65 20 1.89 7.2 181 79
71 26.59 0.55 15 1.94 7.4 186 81 25.8 0.52 15 1.92 7.3 184 81 23.8 0.50 15 1.88 7.1 179 78
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
22.63 1.00 23 1.91 7.4 181 69 22.0 0.98 24 1.89 7.3 179 68 20.3 0.95 25 1.85 7.1 173 66
23.07 0.99 23 1.95 7.6 194 73 22.4 0.95 24 1.93 7.5 192 73 20.7 0.91 24 1.89 7.3 187 71
25.78 0.73 19 2.07 8.1 214 85 25.0 0.69 19 2.06 8.0 212 85 23.1 0.67 20 2.01 7.8 206 82
22.08 1.00 22 2.00 7.9 206 72 21.4 1.00 24 1.99 7.8 204 72 19.8 0.98 25 1.94 7.6 197 70
22.51 1.00 22 2.05 8.1 221 77 21.9 0.98 24 2.03 8.0 219 76 20.2 0.94 24 1.98 7.8 213 74
23.57 0.93 22 2.11 8.3 234 84 22.9 0.88 23 2.10 8.3 231 83 21.1 0.85 23 2.04 8.0 224 81
25.15 0.75 19 2.18 8.7 244 90 24.4 0.72 20 2.16 8.6 241 89 22.5 0.69 20 2.11 8.3 234 86
20.98 1.00 21 2.09 8.4 231 76 20.4 1.00 23 2.07 8.3 229 75 18.8 1.00 24 2.02 8.1 222 73
59 20.62 1.00 21 2.07 8.3 229 75 20.0 1.00 22 2.05 8.2 227 74 18.5 0.97 23 2.00 8.0 220 72 21.38 1.00 21 2.13 8.6 249 81 20.8 1.00 23 2.11 8.5 246 80 19.2 0.98 24 2.06 8.3 239 78
63 21.07 1.00 21 2.11 8.5 246 80 20.5 0.94 22 2.10 8.4 244 79 18.9 0.91 22 2.05 8.2 237 77 22.39 0.96 21 2.20 8.9 263 88 21.7 0.92 22 2.18 8.8 260 87 20.1 0.88 23 2.13 8.6 252 85
67 22.51 0.80 18 2.18 8.8 260 87 21.9 0.77 19 2.16 8.7 258 86 20.2 0.74 19 2.11 8.5 250 84
105ºF
23.89 0.78 19 2.27 9.2 274 94 23.2 0.74 19 2.25 9.1 271 93 21.4 0.72 20 2.20 8.9 263 90
71 24.06 0.60 14 2.25 9.1 271 93 23.4 0.57 15 2.24 9.0 269 92 21.6 0.55 15 2.18 8.8 261 89 19.43 1.00 19 2.16 8.9 256 79 18.9 1.00 21 2.14 8.8 253 78 17.4 1.00 22 2.09 8.6 245 75
59 19.10 1.00 19 2.14 8.8 253 78 18.5 1.00 21 2.12 8.7 251 77 17.1 0.98 21 2.07 8.5 243 75 19.81 1.00 20 2.20 9.1 275 84 19.2 1.00 22 2.19 9.0 272 83 17.7 0.99 22 2.13 8.8 264 80
63 19.51 1.00 19 2.19 9.0 272 83 18.9 0.95 20 2.17 8.9 270 82 17.5 0.92 21 2.12 8.7 262 79 20.74 0.97 20 2.28 9.4 290 91 20.1 0.93 21 2.26 9.3 288 90 18.6 0.89 21 2.20 9.1 279 88
67 20.85 0.81 17 2.26 9.3 288 90 20.2 0.77 18 2.24 9.2 285 89 18.7 0.75 18 2.18 9.0 276 87
115ºF
22.13 0.79 17 2.35 9.8 303 97 21.5 0.75 18 2.33 9.7 300 96 19.8 0.72 18 2.27 9.4 291 93
71 22.29 0.61 13 2.33 9.7 300 96 21.6 0.58 14 2.31 9.6 297 95 20.0 0.56 14 2.25 9.3 288 92
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
24.16 0.90 22 2.01 7.8 205 80 23.5 0.86 23 1.99 7.7 203 79 21.7 0.83 23 1.95 7.5 197 77
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 22.24 22.73 24.28 25.96 21.70 22.17 23.69 25.32 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 22 21 18 15 22 21 18 15 1.89 1.93 1.99 2.06 1.99 2.03 2.10 2.16 7.3 7.5 7.7 8.0 7.8 8.0 8.3 8.6 179 192 203 212 204 219 231 241 68 73 79 85 72 76 83 89 21.6 22.1 23.6 25.2 21.1 21.5 23.0 24.6 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.55 23 22 19 15 23 22 19 15 1.88 1.92 1.98 2.04 1.97 2.01 2.08 2.15 7.2 7.4 7.7 7.9 7.7 7.9 8.2 8.5 177 190 201 210 202 217 229 239 68 72 79 84 71 76 83 88 19.9 20.4 21.8 23.3 19.4 19.9 21.2 22.7 0.90 0.85 0.69 0.52 0.93 0.88 0.71 0.53 23 22 19 15 23 22 19 15 1.83 1.87 1.93 1.99 1.92 1.97 2.03 2.09 7.0 7.2 7.5 7.7 7.5 7.7 8.0 8.3 172 185 195 203 196 210 222 232 66 70 76 81 69 73 80 85
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130241A*** (CONT.)
11
12
www.goodmanmfg.com
59 23.5 0.74 17 1.68 6.7 139 59 22.8 0.71 18 1.66 6.6 138 59 21.1 0.68 18 1.63 6.5 133 57
23.92 0.84 20 1.69 6.7 140 60 23.2 0.80 21 1.68 6.7 139 59 21.4 0.77 21 1.64 6.5 135 58
Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR
MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR
24.62 0.75 18 1.72 6.9 151 64 23.9 0.72 19 1.71 6.8 150 63 22.1 0.69 20 1.67 6.7 145 61
63 24.4 0.62 15 1.71 6.8 150 63 23.7 0.59 16 1.70 6.8 148 63 21.8 0.57 16 1.66 6.6 144 61
26.65 0.57 15 1.77 7.1 160 70 25.9 0.54 16 1.76 7.0 158 69 23.9 0.52 16 1.72 6.9 153 67
67 26.7 0.43 11 1.76 7.0 158 69 25.9 0.41 12 1.74 7.0 156 68 23.9 0.39 12 1.71 6.8 152 66 28.61 0.37 10 1.82 7.3 166 74 27.8 0.35 11 1.81 7.3 165 73 25.6 0.34 11 1.77 7.1 160 71
71 23.36 0.87 20 1.81 7.2 158 63 22.7 0.83 21 1.79 7.2 156 63 20.9 0.80 21 1.75 7.0 151 61
59 23.0 0.77 18 1.79 7.2 156 63 22.3 0.73 18 1.78 7.1 154 62 20.6 0.70 19 1.74 6.9 150 60 24.05 0.78 19 1.84 7.4 170 67 23.4 0.74 19 1.83 7.3 168 67 21.6 0.72 20 1.79 7.1 163 65
63 23.8 0.64 15 1.83 7.3 168 67 23.1 0.61 16 1.81 7.3 166 66 21.3 0.59 16 1.77 7.1 161 64 26.03 0.59 15 1.90 7.6 179 74 25.3 0.56 16 1.88 7.5 177 73 23.3 0.54 16 1.84 7.3 172 71
67 26.1 0.44 12 1.88 7.5 177 73 25.3 0.42 12 1.87 7.5 175 72 23.4 0.41 12 1.83 7.3 170 70
75ºF
27.94 0.38 11 1.95 7.8 187 78 27.1 0.36 11 1.94 7.8 185 78 25.0 0.35 11 1.89 7.6 179 75
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
22.80 0.89 20 1.91 7.8 179 66 22.1 0.85 21 1.90 7.7 177 65 20.4 0.82 22 1.85 7.5 172 63
25.41 0.60 15 2.01 8.2 204 76 24.7 0.58 16 1.99 8.1 202 76 22.8 0.56 16 1.95 7.9 196 73
27.28 0.39 11 2.07 8.5 212 81 26.5 0.37 11 2.05 8.4 210 81 24.4 0.36 11 2.01 8.2 204 78
22.25 0.92 20 2.00 8.3 204 69 21.6 0.88 21 1.99 8.2 202 68 19.9 0.85 22 1.94 8.0 196 66
22.91 0.82 19 2.04 8.4 220 74 22.2 0.79 20 2.03 8.4 217 73 20.53 0.76 20 1.98 8.2 211 71
24.79 0.62 15 2.11 8.7 232 80 24.1 0.60 16 2.09 8.6 230 80 22.2 0.57 16 2.04 8.4 223 77
26.61 0.40 11 2.17 9.0 242 86 25.8 0.38 11 2.15 8.9 239 85 23.8 0.37 11 2.10 8.7 232 82
71 21.14 0.96 20 2.08 8.7 230 72 20.5 0.91 21 2.06 8.7 227 72 18.9 0.88 21 2.02 8.4 220 70
59 20.8 0.84 17 2.06 8.7 227 72 20.2 0.80 18 2.05 8.6 225 71 18.6 0.77 18 2.00 8.4 218 69 21.76 0.86 19 2.12 8.9 247 77 21.1 0.82 19 2.11 8.9 245 76 19.5 0.79 20 2.06 8.6 237 74
63 21.5 0.70 15 2.11 8.9 245 76 20.9 0.67 16 2.09 8.8 242 76 19.3 0.65 16 2.04 8.6 235 73 23.55 0.65 15 2.19 9.2 261 84 22.9 0.62 16 2.17 9.1 258 83 21.1 0.60 16 2.12 8.9 251 81
67 23.6 0.49 11 2.17 9.1 258 83 22.9 0.46 12 2.15 9.0 256 83 21.1 0.45 12 2.10 8.8 248 80
105ºF
25.28 0.42 11 2.26 9.5 272 90 24.5 0.40 11 2.24 9.4 269 89 22.7 0.38 11 2.19 9.2 261 86
71 19.58 0.97 19 2.15 9.2 254 75 19.0 0.92 20 2.13 9.1 251 74 17.5 0.89 20 2.08 8.9 244 72
59 19.3 0.85 16 2.13 9.1 251 74 18.7 0.81 17 2.11 9.0 249 73 17.3 0.78 17 2.07 8.8 241 71 20.16 0.86 17 2.19 9.4 273 80 19.6 0.82 18 2.18 9.3 270 79 18.1 0.79 18 2.12 9.1 262 77
63 20.0 0.71 14 2.18 9.3 270 79 19.4 0.68 15 2.16 9.3 267 78 17.9 0.65 15 2.11 9.0 259 76 21.82 0.65 14 2.26 9.7 288 87 21.2 0.62 15 2.24 9.6 285 86 19.6 0.60 15 2.19 9.4 277 84
67 21.9 0.49 11 2.24 9.6 285 86 21.2 0.47 11 2.23 9.5 282 85 19.6 0.45 11 2.17 9.3 274 83
115ºF
23.42 0.42 10 2.33 10.0 301 93 22.7 0.40 10 2.31 10.0 298 92 21.0 0.39 10 2.26 9.7 289 89
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
23.48 0.80 19 1.95 7.9 193 70 22.8 0.76 19 1.93 7.9 191 69 21.0 0.73 20 1.89 7.7 185 67
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 22.4 23.2 25.5 21.9 22.7 24.8 0.79 0.66 0.45 0.81 0.68 0.47 18 15 12 18 15 12 1.90 1.93 1.99 1.99 2.03 2.09 7.7 7.9 8.1 8.2 8.4 8.6 177 191 202 202 217 230 65 69 76 68 73 80 21.8 22.6 24.7 21.2 22.0 24.1 0.75 0.63 0.43 0.77 0.65 0.45 18 16 12 18 16 12 1.88 1.92 1.98 1.97 2.01 2.07 7.6 7.8 8.0 8.1 8.3 8.5 176 189 200 200 215 227 65 69 75 68 72 79 20.1 20.8 22.8 19.6 20.3 22.3 0.72 0.60 0.42 0.75 0.62 0.43 19 16 12 19 16 12 1.84 1.88 1.93 1.93 1.97 2.02 7.5 7.6 7.8 7.9 8.1 8.3 170 183 194 194 209 220 63 67 73 66 70 76
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130251A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 24.34 0.92 22 1.70 6.8 142 61 23.6 0.88 23 1.69 6.7 140 60 21.8 0.85 24 1.65 6.6 136 58
24.77 0.97 24 1.71 6.8 143 61 24.0 0.92 25 1.70 6.8 142 61 22.2 0.89 25 1.66 6.6 138 59
Airflow MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR
MBh S/T ∆T kW 923 Amps HI PR LO PR MBh S/T ∆T kW 820 Amps HI PR LO PR MBh S/T ∆T kW 718 Amps HI PR LO PR
25.25 0.93 23 1.75 7.0 154 65 24.5 0.89 24 1.73 6.9 153 64 22.6 0.86 25 1.69 6.8 148 63
63 24.87 0.86 21 1.73 6.9 153 64 24.1 0.82 22 1.72 6.9 151 64 22.3 0.80 23 1.68 6.7 147 62
26.44 0.84 22 1.80 7.2 163 71 25.7 0.80 23 1.78 7.1 161 70 23.7 0.77 24 1.74 7.0 156 68
67 26.57 0.70 19 1.78 7.1 161 70 25.8 0.67 19 1.77 7.1 160 70 23.8 0.65 20 1.73 6.9 155 68 28.21 0.68 19 1.85 7.4 170 76 27.4 0.65 20 1.84 7.4 168 75 25.3 0.63 20 1.79 7.2 163 73
71 28.41 0.53 15 1.84 7.4 168 75 27.6 0.50 16 1.82 7.3 166 74 25.5 0.48 16 1.78 7.1 161 72 24.19 1.00 24 1.83 7.3 161 65 23.5 0.96 25 1.82 7.3 159 64 21.7 0.92 26 1.78 7.1 154 62
59 23.78 0.96 23 1.82 7.3 159 64 23.1 0.91 24 1.81 7.2 158 63 21.3 0.88 24 1.77 7.0 153 61 24.66 0.97 24 1.87 7.5 173 69 23.9 0.92 25 1.86 7.4 171 68 22.1 0.89 25 1.81 7.3 166 66
63 24.29 0.90 22 1.86 7.4 171 68 23.6 0.85 23 1.84 7.4 170 67 21.8 0.82 23 1.80 7.2 164 65 25.83 0.87 22 1.92 7.7 183 75 25.1 0.83 23 1.91 7.7 181 74 23.1 0.80 24 1.87 7.5 175 72
67 25.96 0.73 19 1.91 7.7 181 74 25.2 0.70 20 1.90 7.6 179 74 23.3 0.67 20 1.85 7.4 174 71
75ºF
27.55 0.71 19 1.98 8.0 190 80 26.8 0.67 20 1.97 7.9 189 79 24.7 0.65 21 1.92 7.7 183 77
71 27.75 0.55 15 1.97 7.9 189 79 26.9 0.52 16 1.95 7.8 187 78 24.9 0.50 16 1.91 7.7 181 76
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
23.62 1.00 24 1.94 7.9 183 67 22.9 0.98 25 1.92 7.8 181 67 21.2 0.94 26 1.88 7.6 176 65
24.07 0.99 24 1.98 8.1 197 71 23.4 0.95 25 1.96 8.0 195 71 21.6 0.91 25 1.92 7.8 189 69
26.90 0.73 19 2.10 8.6 217 83 26.1 0.69 20 2.08 8.5 214 82 24.1 0.67 21 2.04 8.3 208 80
23.04 1.00 23 2.03 8.4 208 71 22.4 1.00 25 2.02 8.3 206 70 20.6 0.98 26 1.97 8.1 200 68
23.48 1.00 23 2.07 8.6 224 75 22.8 0.98 25 2.06 8.5 222 74 21.0 0.94 25 2.01 8.3 215 72
24.60 0.92 23 2.14 8.8 237 82 23.9 0.88 24 2.12 8.8 234 81 22.0 0.85 24 2.07 8.5 227 79
26.24 0.75 20 2.21 9.1 247 87 25.5 0.71 20 2.19 9.1 244 86 23.5 0.69 21 2.14 8.8 237 84
21.89 1.00 22 2.11 8.9 234 74 21.2 1.00 24 2.10 8.8 232 73 19.6 1.00 25 2.05 8.6 225 71
59 21.51 1.00 21 2.10 8.8 232 73 20.9 1.00 23 2.08 8.7 230 72 19.3 0.97 24 2.03 8.5 223 70 22.31 1.00 22 2.16 9.1 252 79 21.7 1.00 24 2.14 9.0 250 78 20.0 0.98 25 2.09 8.8 242 76
63 21.98 1.00 22 2.14 9.0 250 78 21.3 0.94 22 2.12 8.9 247 77 19.7 0.91 23 2.07 8.7 240 75 23.37 0.96 22 2.22 9.4 266 86 22.7 0.91 23 2.21 9.3 263 85 20.9 0.88 24 2.15 9.0 256 82
67 23.48 0.80 19 2.21 9.3 263 85 22.8 0.76 20 2.19 9.2 261 84 21.0 0.74 20 2.14 9.0 253 82
105ºF
24.93 0.78 19 2.29 9.7 278 91 24.2 0.74 20 2.28 9.6 275 91 22.3 0.71 20 2.22 9.4 267 88
71 25.10 0.60 15 2.28 9.6 275 91 24.4 0.57 16 2.26 9.5 272 90 22.5 0.55 16 2.20 9.3 264 87 20.27 1.00 20 2.18 9.4 259 76 19.7 1.00 22 2.16 9.3 256 76 18.2 1.00 23 2.11 9.0 248 73
59 19.93 1.00 20 2.16 9.3 256 76 19.3 1.00 22 2.15 9.2 254 75 17.9 0.97 22 2.10 9.0 246 73 20.67 1.00 21 2.23 9.6 278 81 20.1 1.00 22 2.21 9.5 276 81 18.5 0.98 23 2.16 9.3 267 78
63 20.36 1.00 20 2.21 9.5 276 81 19.8 0.95 21 2.19 9.4 273 80 18.2 0.91 21 2.14 9.2 265 77 21.64 0.97 21 2.30 9.9 294 89 21.0 0.92 22 2.28 9.8 291 88 19.4 0.89 22 2.22 9.5 282 85
67 21.75 0.81 18 2.28 9.8 291 88 21.1 0.77 18 2.26 9.7 288 87 19.5 0.74 19 2.21 9.5 280 84
115ºF
23.09 0.78 18 2.37 10.2 307 95 22.4 0.75 19 2.35 10.1 304 94 20.7 0.72 19 2.30 9.9 295 91
71 23.25 0.60 14 2.35 10.1 304 94 22.6 0.58 15 2.33 10.0 301 93 20.8 0.56 15 2.28 9.8 292 90
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
25.21 0.89 22 2.04 8.3 208 78 24.5 0.85 23 2.02 8.2 206 77 22.6 0.82 24 1.98 8.0 199 75
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 23.21 23.72 25.34 27.09 22.64 23.14 24.72 26.43 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 23 22 19 15 23 22 19 15 1.92 1.96 2.02 2.08 2.02 2.06 2.12 2.19 7.8 8.0 8.2 8.5 8.3 8.5 8.8 9.1 181 195 206 214 206 222 234 244 67 71 77 82 70 74 81 86 22.5 23.0 24.6 26.3 22.0 22.5 24.0 25.7 0.93 0.88 0.71 0.53 0.96 0.90 0.74 0.55 24 23 20 16 24 23 20 16 1.91 1.95 2.01 2.07 2.00 2.04 2.11 2.17 7.8 7.9 8.2 8.5 8.3 8.4 8.7 9.0 179 193 204 212 204 220 232 242 66 70 76 81 69 74 80 86 20.8 21.3 22.7 24.3 20.3 20.7 22.2 23.7 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 24 23 20 16 24 23 20 16 1.87 1.90 1.96 2.02 1.96 2.00 2.06 2.12 7.6 7.7 8.0 8.2 8.0 8.2 8.5 8.8 174 187 197 206 198 213 225 235 64 68 74 79 67 71 78 83
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130251A*** (CONT.)
13
14
www.goodmanmfg.com
59 27.0 0.75 16 2.04 7.6 141 62 26.6 0.72 17 2.03 7.6 140 62 25.3 0.69 17 2.00 7.4 138 61
27.50 0.85 18 2.05 7.7 143 63 27.1 0.82 19 2.04 7.6 142 63 25.7 0.78 20 2.01 7.5 139 61
Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
28.31 0.76 17 2.10 7.9 154 67 27.9 0.73 18 2.08 7.8 153 67 26.5 0.70 18 2.05 7.7 150 65
63 28.0 0.63 14 2.08 7.8 152 66 27.6 0.60 15 2.07 7.8 151 66 26.2 0.57 15 2.04 7.6 148 65
30.64 0.58 14 2.16 8.1 162 73 30.2 0.55 15 2.15 8.1 161 73 28.7 0.53 15 2.11 7.9 158 71
67 30.7 0.43 10 2.14 8.1 161 73 30.3 0.42 11 2.13 8.0 160 72 28.7 0.40 11 2.10 7.9 156 71 32.89 0.37 10 2.23 8.4 169 78 32.4 0.36 10 2.22 8.4 168 77 30.8 0.34 10 2.18 8.2 165 76
71 26.86 0.88 19 2.21 8.3 160 67 26.5 0.85 20 2.19 8.3 159 66 25.1 0.81 20 2.16 8.1 156 65
59 26.4 0.78 16 2.19 8.2 159 66 26.0 0.74 17 2.18 8.2 158 66 24.7 0.71 17 2.14 8.0 154 64 27.65 0.79 17 2.25 8.5 173 71 27.2 0.76 18 2.24 8.5 171 70 25.9 0.73 19 2.21 8.3 168 69
63 27.4 0.65 14 2.24 8.4 171 70 27.0 0.62 15 2.22 8.4 170 70 25.6 0.60 15 2.19 8.2 166 68 29.93 0.60 14 2.32 8.8 182 77 29.5 0.57 15 2.31 8.8 181 77 28.0 0.55 15 2.27 8.6 177 75
67 30.0 0.45 11 2.31 8.7 180 77 29.5 0.43 11 2.29 8.7 179 76 28.1 0.41 11 2.26 8.5 176 75
75ºF
32.12 0.38 10 2.40 9.1 190 82 31.6 0.37 10 2.38 9.1 189 82 30.1 0.35 11 2.35 8.9 185 80
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
26.22 0.91 19 2.34 9.0 182 69 25.8 0.87 20 2.33 9.0 181 69 24.5 0.83 20 2.29 8.8 177 67
29.22 0.61 14 2.47 9.6 207 80 28.8 0.59 15 2.45 9.5 206 80 27.3 0.56 15 2.41 9.3 202 78
31.36 0.39 10 2.55 9.9 216 86 30.9 0.38 10 2.53 9.9 215 85 29.4 0.36 11 2.49 9.7 210 83
25.58 0.94 19 2.46 9.7 208 73 25.2 0.90 20 2.45 9.6 206 72 23.9 0.86 20 2.41 9.4 202 71
26.34 0.84 17 2.52 9.9 224 77 25.9 0.80 18 2.50 9.9 222 77 24.65 0.77 19 2.46 9.7 218 75
28.51 0.63 14 2.60 10.3 236 85 28.1 0.61 15 2.58 10.2 234 84 26.7 0.58 15 2.54 10.0 230 82
30.59 0.41 10 2.68 10.6 246 90 30.1 0.39 10 2.67 10.6 244 89 28.6 0.37 11 2.62 10.4 240 88
71 24.30 0.97 18 2.56 10.3 234 76 23.9 0.93 19 2.55 10.2 232 76 22.7 0.89 20 2.51 10.0 227 74
59 23.9 0.85 16 2.54 10.2 231 75 23.5 0.82 17 2.53 10.1 230 75 22.4 0.78 17 2.49 10.0 225 73 25.02 0.87 17 2.62 10.6 251 81 24.6 0.83 18 2.60 10.5 250 81 23.4 0.80 19 2.56 10.3 245 79
63 24.8 0.71 14 2.60 10.5 249 80 24.4 0.68 15 2.58 10.4 247 80 23.2 0.65 15 2.54 10.2 242 78 27.08 0.66 14 2.70 10.9 266 89 26.7 0.63 15 2.69 10.8 264 88 25.3 0.60 15 2.64 10.6 258 86
67 27.1 0.49 11 2.68 10.8 263 88 26.7 0.47 11 2.67 10.7 261 87 25.4 0.45 11 2.62 10.5 256 85
105ºF
29.06 0.42 10 2.79 11.3 277 94 28.6 0.40 10 2.78 11.3 275 94 27.2 0.39 10 2.73 11.1 270 92
71 22.51 0.98 17 2.65 10.9 258 79 22.2 0.94 18 2.64 10.9 256 78 21.1 0.90 19 2.59 10.7 251 77
59 22.1 0.86 15 2.63 10.8 256 78 21.8 0.82 16 2.61 10.8 254 78 20.7 0.79 16 2.57 10.6 249 76 23.17 0.88 16 2.71 11.2 278 84 22.8 0.84 17 2.69 11.1 276 83 21.7 0.80 17 2.65 10.9 270 82
63 22.9 0.72 13 2.69 11.1 275 83 22.6 0.69 14 2.67 11.0 273 82 21.5 0.66 14 2.63 10.8 268 81 25.08 0.66 13 2.80 11.6 293 92 24.7 0.63 14 2.78 11.5 291 91 23.5 0.61 14 2.74 11.3 286 89
67 25.1 0.50 10 2.77 11.5 290 91 24.8 0.48 10 2.76 11.4 288 90 23.5 0.46 11 2.71 11.2 283 88
115ºF
26.92 0.43 9 2.89 12.0 306 98 26.5 0.41 9 2.87 11.9 304 97 25.2 0.39 10 2.83 11.7 298 95
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
26.99 0.81 17 2.39 9.3 196 74 26.6 0.78 18 2.38 9.2 195 73 25.3 0.74 19 2.34 9.0 191 72
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 25.8 26.7 29.3 25.2 26.1 28.6 0.80 0.67 0.46 0.82 0.69 0.48 16 14 11 16 14 11 2.32 2.37 2.45 2.44 2.49 2.57 9.0 9.2 9.5 9.6 9.8 10.2 181 194 205 206 221 234 69 73 80 72 77 84 25.4 26.3 28.8 24.8 25.7 28.1 0.76 0.64 0.44 0.79 0.66 0.46 17 15 11 17 15 11 2.31 2.36 2.43 2.43 2.48 2.56 8.9 9.1 9.4 9.5 9.8 10.1 179 193 204 204 220 232 68 72 79 72 76 83 24.1 25.0 27.4 23.5 24.4 26.7 0.73 0.61 0.42 0.75 0.63 0.44 18 15 12 18 15 12 2.27 2.32 2.40 2.39 2.44 2.52 8.7 9.0 9.3 9.3 9.6 9.9 176 189 200 200 215 227 67 71 78 70 75 81
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130301A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 27.99 0.94 21 2.07 7.8 144 64 27.6 0.90 22 2.06 7.7 143 63 26.2 0.86 22 2.03 7.6 140 62
28.47 0.98 22 2.09 7.8 146 64 28.1 0.94 23 2.07 7.8 145 64 26.7 0.90 24 2.04 7.6 142 63
Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
29.03 0.95 22 2.13 8.0 157 68 28.6 0.91 23 2.12 8.0 156 68 27.2 0.87 23 2.08 7.8 153 67
63 28.60 0.88 20 2.11 8.0 155 68 28.2 0.84 21 2.10 7.9 154 67 26.8 0.80 21 2.07 7.8 151 66
30.40 0.85 20 2.19 8.3 166 75 29.9 0.82 21 2.18 8.2 165 74 28.5 0.78 22 2.15 8.1 161 73
67 30.55 0.71 17 2.18 8.2 164 74 30.1 0.68 18 2.17 8.2 163 74 28.6 0.65 19 2.13 8.0 160 72 32.43 0.69 18 2.26 8.6 173 80 32.0 0.66 19 2.25 8.5 172 79 30.4 0.64 19 2.22 8.4 168 77
71 32.66 0.53 14 2.25 8.5 171 79 32.2 0.51 14 2.23 8.5 170 78 30.6 0.49 15 2.20 8.3 166 77 27.81 1.00 22 2.24 8.5 164 68 27.4 0.97 23 2.23 8.4 162 68 26.0 0.93 24 2.19 8.3 159 66
59 27.33 0.97 21 2.22 8.4 162 67 26.9 0.93 22 2.21 8.3 161 67 25.6 0.89 23 2.18 8.2 158 66 28.35 0.98 22 2.29 8.7 176 72 27.9 0.94 23 2.28 8.6 175 72 26.5 0.90 24 2.24 8.5 171 70
63 27.93 0.91 20 2.27 8.6 174 72 27.5 0.87 21 2.26 8.5 173 71 26.1 0.83 22 2.22 8.4 170 70 29.69 0.89 21 2.36 9.0 186 79 29.3 0.85 22 2.35 8.9 185 78 27.8 0.81 22 2.31 8.8 181 77
67 29.84 0.74 17 2.34 8.9 184 78 29.4 0.71 18 2.33 8.8 183 78 27.9 0.68 19 2.29 8.7 179 76
75ºF
31.68 0.72 18 2.44 9.3 194 84 31.2 0.69 19 2.42 9.3 193 84 29.6 0.66 19 2.38 9.1 189 82
71 31.90 0.55 14 2.42 9.2 192 83 31.4 0.53 15 2.40 9.2 191 83 29.9 0.51 15 2.37 9.0 187 81
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
27.15 1.00 21 2.38 9.2 186 71 26.7 1.00 23 2.37 9.2 185 70 25.4 0.96 24 2.33 9.0 181 69
27.68 1.00 22 2.43 9.4 200 75 27.3 0.96 23 2.42 9.4 199 75 25.9 0.92 24 2.38 9.2 195 73
30.92 0.74 18 2.59 10.1 221 87 30.5 0.71 19 2.58 10.1 219 87 28.9 0.68 19 2.53 9.9 215 85
26.49 1.00 21 2.50 9.9 212 74 26.1 1.00 23 2.49 9.8 210 74 24.8 0.99 24 2.45 9.6 206 72
27.00 1.00 21 2.56 10.1 228 79 26.6 0.99 23 2.54 10.0 226 78 25.3 0.95 24 2.50 9.9 222 77
28.28 0.94 21 2.64 10.4 241 86 27.9 0.90 22 2.62 10.4 239 86 26.5 0.86 23 2.58 10.2 234 84
30.17 0.76 18 2.73 10.8 251 92 29.7 0.73 19 2.71 10.8 249 91 28.2 0.70 20 2.66 10.6 244 89
25.16 1.00 20 2.61 10.5 238 78 24.8 1.00 22 2.59 10.4 237 77 23.6 1.00 23 2.55 10.2 232 76
59 24.73 1.00 19 2.58 10.4 236 77 24.4 1.00 21 2.57 10.3 234 76 23.1 0.98 22 2.53 10.1 230 75 25.65 1.00 20 2.66 10.8 257 83 25.3 1.00 22 2.65 10.7 255 82 24.0 0.99 24 2.60 10.5 250 81
63 25.27 1.00 20 2.64 10.7 254 82 24.9 0.96 21 2.63 10.6 252 81 23.7 0.92 21 2.58 10.4 247 80 26.86 0.97 20 2.75 11.1 271 90 26.5 0.93 22 2.73 11.1 269 90 25.1 0.89 22 2.69 10.8 264 88
67 27.00 0.81 17 2.73 11.0 268 89 26.6 0.78 18 2.71 11.0 266 89 25.3 0.75 19 2.67 10.7 261 87
105ºF
28.66 0.79 18 2.84 11.6 283 96 28.2 0.76 19 2.82 11.5 281 96 26.8 0.72 19 2.78 11.3 275 94
71 28.86 0.61 14 2.82 11.4 280 95 28.4 0.58 14 2.80 11.4 278 95 27.0 0.56 15 2.75 11.2 272 93 23.31 1.00 18 2.70 11.1 263 80 23.0 1.00 20 2.68 11.1 262 80 21.8 1.00 22 2.64 10.9 256 78
59 22.91 1.00 18 2.67 11.0 261 80 22.6 1.00 20 2.66 11.0 259 79 21.4 0.99 21 2.61 10.8 254 78 23.76 1.00 19 2.75 11.4 283 86 23.4 1.00 20 2.74 11.3 281 85 22.2 1.00 22 2.69 11.1 276 83
63 23.41 1.00 18 2.73 11.3 281 85 23.1 0.96 19 2.72 11.2 279 84 21.9 0.92 20 2.67 11.0 273 82 24.88 0.98 19 2.84 11.8 299 93 24.5 0.94 20 2.83 11.7 297 93 23.3 0.90 21 2.78 11.5 291 91
67 25.01 0.82 16 2.82 11.7 296 93 24.6 0.78 17 2.80 11.6 294 92 23.4 0.75 17 2.76 11.4 288 90
115ºF
26.55 0.80 17 2.94 12.3 312 100 26.2 0.76 17 2.92 12.2 310 99 24.8 0.73 18 2.87 11.9 304 97
71 26.74 0.61 13 2.92 12.1 309 99 26.3 0.59 14 2.90 12.1 307 98 25.0 0.56 14 2.85 11.8 301 96
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
28.98 0.91 21 2.51 9.8 211 82 28.6 0.87 22 2.49 9.7 210 82 27.1 0.83 22 2.45 9.5 206 80
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 26.68 27.27 29.13 31.14 26.03 26.60 28.42 30.38 1.00 0.93 0.76 0.57 1.00 0.96 0.78 0.59 21 20 17 14 20 20 17 14 2.36 2.41 2.49 2.57 2.48 2.54 2.62 2.70 9.1 9.4 9.7 10.0 9.8 10.0 10.3 10.7 184 198 209 218 210 226 238 249 70 74 81 87 74 78 85 91 26.3 26.9 28.7 30.7 25.6 26.2 28.0 29.9 0.95 0.89 0.73 0.54 0.98 0.92 0.75 0.56 22 21 18 15 22 21 18 15 2.35 2.40 2.47 2.55 2.47 2.52 2.60 2.69 9.1 9.3 9.6 10.0 9.7 9.9 10.3 10.7 183 197 208 217 208 224 237 247 69 74 81 86 73 78 85 90 25.0 25.5 27.3 29.1 24.4 24.9 26.6 28.4 0.91 0.86 0.70 0.52 0.94 0.88 0.72 0.54 23 22 19 15 23 22 19 15 2.31 2.36 2.43 2.51 2.43 2.48 2.56 2.64 8.9 9.1 9.4 9.8 9.5 9.8 10.1 10.5 179 193 204 212 204 220 232 242 68 72 79 84 72 76 83 88
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130301A*** (CONT.)
15
16
www.goodmanmfg.com
59 26.5 0.78 16 1.81 8.0 147 61 26.1 0.74 17 1.80 7.9 146 61 24.8 0.71 18 1.77 7.8 143 60
26.91 0.88 19 1.83 8.0 149 62 26.5 0.85 20 1.82 8.0 148 62 25.2 0.81 20 1.79 7.9 145 60
Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
27.70 0.79 17 1.87 8.2 160 66 27.3 0.76 18 1.86 8.2 159 66 25.9 0.72 19 1.83 8.0 156 64
63 27.4 0.65 14 1.85 8.1 159 65 27.0 0.62 15 1.84 8.1 158 65 25.7 0.60 15 1.81 8.0 154 64
29.99 0.60 14 1.93 8.5 169 72 29.5 0.57 15 1.92 8.4 168 72 28.1 0.55 15 1.89 8.3 165 70
67 30.0 0.45 11 1.91 8.4 168 71 29.6 0.43 11 1.90 8.3 166 71 28.1 0.41 12 1.87 8.2 163 69 32.18 0.38 10 1.99 8.8 177 77 31.7 0.37 10 1.98 8.7 175 76 30.1 0.35 11 1.95 8.6 172 75
71 26.28 0.92 19 1.97 8.6 167 66 25.9 0.88 20 1.96 8.6 166 65 24.6 0.84 20 1.93 8.4 163 64
59 25.8 0.81 16 1.96 8.6 165 65 25.5 0.77 17 1.95 8.5 164 64 24.2 0.74 18 1.91 8.4 161 63 27.06 0.82 17 2.02 8.8 180 70 26.7 0.78 18 2.01 8.8 179 69 25.3 0.75 19 1.97 8.6 175 68
63 26.8 0.67 14 2.00 8.8 178 69 26.4 0.64 15 1.99 8.7 177 69 25.1 0.62 15 1.96 8.6 173 67 29.29 0.62 14 2.09 9.1 190 76 28.9 0.59 15 2.07 9.1 189 76 27.4 0.57 15 2.04 8.9 185 74
67 29.3 0.47 11 2.07 9.0 188 75 28.9 0.45 11 2.06 9.0 187 75 27.5 0.43 12 2.02 8.8 183 73
75ºF
31.43 0.40 10 2.16 9.4 198 81 31.0 0.38 10 2.15 9.4 197 81 29.4 0.37 11 2.11 9.2 193 79
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
25.66 0.94 19 2.11 9.3 190 68 25.3 0.90 20 2.09 9.3 189 68 24.0 0.86 21 2.06 9.1 185 66
28.59 0.64 14 2.23 9.8 216 79 28.2 0.61 15 2.21 9.8 215 79 26.8 0.58 15 2.17 9.6 210 77
30.69 0.41 10 2.30 10.2 225 84 30.2 0.39 10 2.29 10.1 224 84 28.7 0.38 11 2.25 10.0 219 82
25.03 0.97 19 2.22 9.9 216 72 24.7 0.93 20 2.21 9.9 215 71 23.4 0.89 21 2.17 9.7 211 70
25.77 0.87 18 2.27 10.2 233 76 25.4 0.83 18 2.26 10.1 231 76 24.12 0.80 19 2.22 9.9 227 74
27.89 0.66 14 2.35 10.5 246 83 27.5 0.63 15 2.34 10.4 244 83 26.1 0.60 16 2.29 10.2 239 81
29.94 0.42 10 2.43 10.9 257 89 29.5 0.40 10 2.42 10.8 255 88 28.0 0.39 11 2.37 10.6 250 86
71 23.78 1.00 19 2.32 10.5 244 75 23.4 0.96 20 2.30 10.5 242 74 22.3 0.92 20 2.26 10.3 237 73
59 23.4 0.89 16 2.30 10.5 241 74 23.0 0.85 17 2.28 10.4 239 74 21.9 0.81 18 2.24 10.2 235 72 24.48 0.90 17 2.37 10.8 262 80 24.1 0.86 18 2.36 10.7 260 79 22.9 0.83 19 2.32 10.5 255 78
63 24.2 0.74 14 2.35 10.7 259 79 23.9 0.71 15 2.34 10.6 258 78 22.7 0.68 15 2.30 10.4 253 77 26.50 0.68 14 2.45 11.1 277 87 26.1 0.65 15 2.44 11.1 275 86 24.8 0.62 15 2.40 10.9 269 85
67 26.6 0.51 11 2.43 11.0 274 86 26.2 0.49 11 2.42 11.0 272 86 24.9 0.47 12 2.38 10.8 267 84
105ºF
28.44 0.44 10 2.54 11.5 289 93 28.0 0.42 10 2.52 11.5 287 92 26.6 0.40 11 2.48 11.3 281 90
71 22.03 1.00 17 2.40 11.1 269 78 21.7 0.97 18 2.39 11.1 267 77 20.6 0.93 19 2.35 10.9 262 75
59 21.7 0.89 15 2.38 11.0 266 77 21.3 0.85 16 2.37 11.0 265 76 20.3 0.82 16 2.33 10.8 259 75 22.68 0.91 16 2.46 11.4 290 83 22.3 0.87 17 2.44 11.3 288 82 21.2 0.83 18 2.40 11.1 282 80
63 22.4 0.75 13 2.44 11.3 287 82 22.1 0.71 14 2.42 11.2 285 81 21.0 0.68 14 2.38 11.0 279 80 24.55 0.69 13 2.54 11.8 306 90 24.2 0.66 14 2.53 11.7 304 89 23.0 0.63 14 2.48 11.5 298 88
67 24.6 0.52 10 2.52 11.7 303 89 24.2 0.49 10 2.51 11.6 301 89 23.0 0.47 11 2.46 11.4 295 87
115ºF
26.35 0.44 9 2.63 12.2 319 96 26.0 0.42 10 2.62 12.1 317 95 24.7 0.41 10 2.57 11.9 310 93
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
26.42 0.84 17 2.15 9.6 205 72 26.0 0.80 18 2.14 9.5 203 72 24.7 0.77 19 2.10 9.3 199 71
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 25.2 26.1 28.6 24.6 25.5 28.0 0.83 0.69 0.48 0.85 0.71 0.49 16 14 11 16 14 11 2.09 2.13 2.21 2.20 2.25 2.33 9.3 9.5 9.8 9.9 10.1 10.4 188 202 214 214 231 244 67 72 78 71 75 82 24.9 25.8 28.2 24.2 25.1 27.5 0.79 0.66 0.46 0.82 0.68 0.47 17 15 11 17 15 11 2.07 2.12 2.19 2.19 2.24 2.31 9.2 9.4 9.7 9.8 10.0 10.3 187 201 212 213 229 242 67 71 78 70 75 82 23.6 24.5 26.8 23.0 23.9 26.2 0.76 0.63 0.44 0.78 0.65 0.45 18 15 12 18 15 12 2.04 2.09 2.16 2.15 2.20 2.27 9.0 9.3 9.5 9.6 9.8 10.2 183 197 208 209 224 237 66 70 76 69 73 80
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130311A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 27.39 0.97 21 1.84 8.1 150 63 27.0 0.93 22 1.83 8.1 149 62 25.6 0.89 23 1.80 7.9 146 61
27.86 1.00 22 1.86 8.2 152 63 27.5 0.97 23 1.85 8.1 151 63 26.1 0.93 24 1.82 8.0 148 62
Airflow MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
MBh S/T ∆T 1173 kW Amps HI PR LO PR MBh S/T ∆T 1050 kW Amps HI PR LO PR MBh S/T ∆T kW 927 Amps HI PR LO PR
28.40 0.98 22 1.90 8.4 164 67 28.0 0.94 23 1.89 8.3 162 67 26.6 0.90 24 1.86 8.2 159 66
63 27.98 0.91 20 1.88 8.3 162 67 27.6 0.87 21 1.87 8.2 161 66 26.2 0.83 22 1.84 8.1 158 65
29.75 0.88 21 1.96 8.6 173 74 29.3 0.85 22 1.95 8.6 171 73 27.8 0.81 22 1.92 8.4 168 72
67 29.90 0.74 17 1.95 8.5 171 73 29.5 0.71 18 1.93 8.5 170 72 28.0 0.68 19 1.90 8.3 166 71 31.74 0.72 18 2.03 8.9 180 78 31.3 0.69 19 2.02 8.9 179 78 29.7 0.66 19 1.98 8.7 175 76
71 31.96 0.55 14 2.01 8.8 178 78 31.5 0.53 15 2.00 8.8 177 77 29.9 0.51 15 1.97 8.6 174 75 27.22 1.00 21 2.01 8.8 171 67 26.8 1.00 23 2.00 8.7 169 66 25.5 0.97 24 1.96 8.6 166 65
59 26.75 1.00 21 1.99 8.7 169 66 26.4 0.96 22 1.98 8.7 168 66 25.0 0.92 23 1.95 8.5 164 64 27.74 1.00 22 2.05 9.0 183 71 27.3 0.97 23 2.04 8.9 182 71 26.0 0.93 24 2.01 8.8 179 69
63 27.33 0.94 20 2.04 8.9 182 70 26.9 0.90 21 2.02 8.9 180 70 25.6 0.86 22 1.99 8.7 177 69 29.06 0.92 21 2.12 9.3 194 78 28.6 0.88 22 2.11 9.2 192 77 27.2 0.84 23 2.07 9.1 189 76
67 29.20 0.77 18 2.11 9.2 192 77 28.8 0.73 18 2.09 9.1 191 76 27.3 0.70 19 2.06 9.0 187 75
75ºF
31.00 0.74 18 2.20 9.6 202 83 30.5 0.71 19 2.18 9.5 201 82 29.0 0.68 20 2.15 9.4 197 80
71 31.22 0.57 14 2.18 9.5 200 82 30.8 0.55 15 2.16 9.5 199 81 29.2 0.53 15 2.13 9.3 195 80
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
26.57 1.00 21 2.14 9.5 194 70 26.2 1.00 23 2.13 9.4 193 69 24.9 0.99 24 2.09 9.3 189 68
27.08 1.00 21 2.19 9.7 209 74 26.7 1.00 23 2.18 9.7 207 73 25.3 0.96 24 2.14 9.5 203 72
30.26 0.76 18 2.34 10.4 230 86 29.8 0.73 19 2.33 10.3 228 85 28.3 0.70 20 2.29 10.1 224 84
25.92 1.00 20 2.26 10.1 221 73 25.5 1.00 22 2.25 10.1 219 72 24.3 1.00 24 2.21 9.9 215 71
26.42 1.00 21 2.31 10.3 238 78 26.0 1.00 23 2.30 10.3 236 77 24.7 0.99 24 2.26 10.1 231 76
27.67 0.97 21 2.39 10.7 251 85 27.3 0.93 22 2.38 10.6 249 84 25.9 0.89 23 2.33 10.4 244 83
29.52 0.79 18 2.47 11.1 262 90 29.1 0.75 19 2.46 11.0 260 90 27.6 0.72 20 2.42 10.8 255 88
24.62 1.00 19 2.36 10.7 248 77 24.3 1.00 21 2.34 10.7 247 76 23.0 1.00 23 2.30 10.5 242 74
59 24.20 1.00 19 2.34 10.6 246 76 23.8 1.00 21 2.32 10.6 244 75 22.7 1.01 23 2.28 10.4 239 74 25.10 1.00 20 2.41 11.0 267 81 24.7 1.00 22 2.40 10.9 266 81 23.5 1.00 23 2.36 10.7 260 79
63 24.73 1.00 19 2.39 10.9 265 81 24.4 0.99 21 2.38 10.8 263 80 23.1 0.95 22 2.34 10.6 258 78 26.29 1.00 21 2.50 11.3 282 89 25.9 0.96 22 2.48 11.3 280 88 24.6 0.92 23 2.44 11.1 275 86
67 26.42 0.84 17 2.48 11.2 280 88 26.0 0.81 18 2.46 11.2 278 87 24.7 0.77 19 2.42 11.0 272 86
105ºF
28.05 0.82 18 2.59 11.7 295 95 27.6 0.78 19 2.57 11.7 292 94 26.2 0.75 20 2.52 11.5 287 92
71 28.24 0.63 14 2.56 11.6 292 94 27.8 0.60 15 2.55 11.6 290 93 26.4 0.58 15 2.50 11.4 284 91 22.81 1.00 18 2.45 11.3 275 79 22.5 1.00 20 2.43 11.3 273 79 21.3 1.00 21 2.39 11.1 267 77
59 22.42 1.00 18 2.42 11.2 272 78 22.1 1.00 19 2.41 11.2 270 78 21.0 1.02 21 2.37 11.0 265 76 23.25 1.00 18 2.50 11.6 295 84 22.9 1.00 20 2.49 11.5 293 84 21.8 1.00 22 2.44 11.3 288 82
63 22.91 1.00 18 2.48 11.5 293 83 22.6 1.00 20 2.47 11.4 290 83 21.4 0.96 20 2.42 11.2 285 81 24.35 1.00 19 2.59 12.0 312 92 24.0 0.97 20 2.57 11.9 310 91 22.8 0.93 21 2.53 11.7 304 89
67 24.47 0.85 16 2.57 11.9 309 91 24.1 0.81 17 2.55 11.8 307 90 22.9 0.78 18 2.51 11.6 301 89
115ºF
25.98 0.82 17 2.68 12.4 325 98 25.6 0.79 18 2.66 12.3 323 97 24.3 0.76 18 2.62 12.1 317 95
71 26.16 0.63 13 2.66 12.3 322 97 25.8 0.61 14 2.64 12.2 320 96 24.5 0.58 14 2.59 12.0 314 94
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
28.36 0.94 21 2.27 10.0 220 81 27.9 0.90 22 2.25 10.0 219 80 26.5 0.86 23 2.21 9.8 214 79
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 26.11 26.68 28.51 30.47 25.47 26.03 27.81 29.73 1.00 0.97 0.79 0.59 1.00 1.00 0.81 0.61 20 20 18 14 20 20 18 14 2.12 2.17 2.25 2.32 2.24 2.29 2.37 2.45 9.4 9.6 9.9 10.3 10.0 10.3 10.6 11.0 192 207 218 228 219 235 249 259 69 73 80 85 72 77 84 89 25.7 26.3 28.1 30.0 25.1 25.6 27.4 29.3 0.99 0.92 0.75 0.56 1.00 0.95 0.78 0.58 22 21 19 15 22 21 19 15 2.11 2.16 2.23 2.31 2.23 2.28 2.36 2.44 9.4 9.6 9.9 10.2 10.0 10.2 10.5 10.9 191 205 217 226 217 234 247 257 68 73 79 85 72 76 83 89 24.4 25.0 26.7 28.5 23.8 24.4 26.0 27.8 0.94 0.89 0.72 0.54 0.98 0.91 0.74 0.56 23 22 19 15 23 22 19 15 2.07 2.12 2.19 2.27 2.19 2.24 2.31 2.40 9.2 9.4 9.7 10.0 9.8 10.0 10.3 10.7 187 201 212 221 213 229 242 252 67 71 78 83 70 75 82 87
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130311A*** (CONT.)
17
18
www.goodmanmfg.com
59 33.8 0.76 17 2.47 9.2 143 65 33.3 0.73 17 2.46 9.1 142 65 31.6 0.69 18 2.42 9.0 139 63
34.37 0.86 19 2.49 9.3 145 66 33.9 0.82 20 2.48 9.2 144 65 32.2 0.79 21 2.44 9.0 141 64
Airflow MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR
MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR
35.39 0.77 18 2.54 9.5 156 70 34.9 0.74 19 2.53 9.4 155 70 33.1 0.71 19 2.49 9.2 151 68
63 35.0 0.63 14 2.52 9.4 154 69 34.5 0.61 15 2.51 9.3 153 69 32.8 0.58 16 2.47 9.2 150 67
38.30 0.58 14 2.62 9.8 164 76 37.7 0.56 15 2.60 9.7 163 76 35.9 0.53 16 2.56 9.5 160 74
67 38.4 0.44 11 2.60 9.7 163 76 37.8 0.42 11 2.58 9.6 162 75 35.9 0.40 12 2.54 9.5 158 74 41.11 0.37 10 2.69 10.1 171 81 40.5 0.36 10 2.68 10.1 170 81 38.5 0.34 11 2.64 9.9 167 79
71 33.57 0.89 19 2.67 10.0 162 70 33.1 0.85 20 2.66 9.9 161 69 31.4 0.82 21 2.62 9.7 158 68
59 33.0 0.79 17 2.65 9.9 161 69 32.5 0.75 18 2.64 9.8 159 68 30.9 0.72 18 2.60 9.7 156 67 34.56 0.80 18 2.72 10.2 175 74 34.1 0.76 19 2.71 10.2 173 73 32.4 0.73 19 2.67 10.0 170 72
63 34.2 0.66 14 2.70 10.1 173 73 33.7 0.63 15 2.69 10.1 172 73 32.0 0.60 16 2.65 9.9 168 71 37.41 0.60 15 2.81 10.5 184 81 36.9 0.58 15 2.79 10.5 183 80 35.0 0.55 16 2.75 10.3 179 79
67 37.5 0.45 11 2.79 10.5 183 80 36.9 0.43 12 2.77 10.4 181 79 35.1 0.42 12 2.73 10.2 178 78
75ºF
40.15 0.39 10 2.89 10.9 192 86 39.6 0.37 11 2.88 10.9 191 85 37.6 0.36 11 2.83 10.7 187 84
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
32.77 0.91 19 2.83 10.8 185 72 32.3 0.88 20 2.81 10.8 183 72 30.7 0.84 21 2.77 10.6 180 70
36.52 0.62 15 2.98 11.4 210 84 36.0 0.59 15 2.96 11.4 208 83 34.2 0.57 16 2.91 11.2 204 82
39.20 0.40 10 3.07 11.9 219 89 38.6 0.38 11 3.05 11.8 217 89 36.7 0.37 11 3.00 11.6 213 87
31.97 0.94 19 2.97 11.6 210 76 31.5 0.90 21 2.95 11.5 209 75 29.9 0.87 21 2.91 11.3 205 74
32.92 0.84 18 3.03 11.8 226 81 32.4 0.81 19 3.01 11.8 225 80 30.81 0.77 20 2.97 11.5 220 79
35.63 0.64 15 3.13 12.2 239 88 35.1 0.61 15 3.11 12.1 237 88 33.3 0.59 16 3.06 11.9 232 86
38.24 0.41 10 3.23 12.7 249 94 37.7 0.39 11 3.21 12.6 247 93 35.8 0.38 11 3.16 12.4 242 91
71 30.37 0.98 19 3.09 12.3 236 80 29.9 0.94 20 3.07 12.2 235 79 28.4 0.90 21 3.02 12.0 230 77
59 29.9 0.86 17 3.06 12.2 234 79 29.4 0.83 18 3.05 12.1 232 78 28.0 0.79 18 3.00 11.9 228 77 31.27 0.88 18 3.15 12.6 254 85 30.8 0.84 19 3.14 12.5 253 84 29.3 0.80 19 3.09 12.3 248 82
63 31.0 0.72 14 3.13 12.5 252 84 30.5 0.69 15 3.11 12.4 250 83 29.0 0.66 16 3.06 12.2 245 82 33.85 0.66 14 3.25 13.0 269 92 33.3 0.64 15 3.23 12.9 267 92 31.7 0.61 16 3.18 12.7 261 90
67 33.9 0.50 11 3.23 12.9 266 91 33.4 0.48 12 3.21 12.8 264 91 31.7 0.46 12 3.16 12.6 259 89
105ºF
36.33 0.43 10 3.36 13.5 280 98 35.8 0.41 11 3.34 13.4 278 98 34.0 0.39 11 3.28 13.2 273 96
71 28.14 0.99 18 3.19 13.0 261 82 27.7 0.95 19 3.17 12.9 259 82 26.3 0.91 20 3.12 12.7 254 80
59 27.7 0.87 16 3.16 12.9 259 81 27.3 0.83 16 3.15 12.8 257 81 25.9 0.80 17 3.10 12.6 252 79 28.97 0.88 17 3.26 13.3 281 88 28.5 0.85 17 3.24 13.2 279 87 27.1 0.81 18 3.19 13.0 274 85
63 28.7 0.73 13 3.23 13.2 278 87 28.3 0.70 14 3.21 13.1 276 86 26.8 0.67 15 3.16 12.9 271 84 31.36 0.67 14 3.36 13.8 297 96 30.9 0.64 14 3.34 13.7 295 95 29.3 0.61 15 3.29 13.4 289 93
67 31.4 0.50 10 3.33 13.6 294 95 31.0 0.48 11 3.32 13.6 292 94 29.4 0.46 11 3.26 13.3 286 92
115ºF
33.65 0.43 9 3.47 14.3 310 102 33.2 0.41 10 3.45 14.2 307 101 31.5 0.39 10 3.39 13.9 301 99
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
33.74 0.82 18 2.89 11.1 199 77 33.2 0.78 19 2.87 11.0 197 76 31.6 0.75 19 2.83 10.8 193 75
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 32.2 33.4 36.6 31.4 32.6 35.7 0.80 0.67 0.47 0.83 0.69 0.48 17 14 11 17 15 11 2.81 2.86 2.95 2.95 3.01 3.10 10.7 11.0 11.3 11.5 11.7 12.1 183 197 208 208 224 236 72 76 83 75 80 87 31.7 32.9 36.1 31.0 32.1 35.2 0.77 0.64 0.45 0.80 0.66 0.46 18 15 12 18 15 12 2.79 2.85 2.94 2.93 2.99 3.08 10.7 10.9 11.3 11.4 11.7 12.0 181 195 206 207 222 235 71 76 82 75 79 87 30.2 31.3 34.3 29.4 30.5 33.4 0.74 0.62 0.43 0.76 0.64 0.44 18 16 12 18 16 12 2.75 2.81 2.89 2.88 2.94 3.03 10.5 10.7 11.1 11.2 11.4 11.8 178 191 202 202 218 230 70 74 81 73 78 85
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130361A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 34.98 0.94 21 2.51 9.3 146 66 34.5 0.90 22 2.50 9.3 145 66 32.7 0.87 23 2.46 9.1 142 65
35.59 0.99 23 2.53 9.4 148 67 35.1 0.95 24 2.52 9.4 146 67 33.3 0.91 25 2.48 9.2 144 65
Airflow MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR
MBh S/T ∆T 1425 kW Amps HI PR LO PR MBh S/T ∆T 1275 kW Amps HI PR LO PR MBh S/T ∆T 1125 kW Amps HI PR LO PR
36.28 0.96 22 2.58 9.6 159 71 35.7 0.91 24 2.57 9.6 158 71 34.0 0.88 24 2.53 9.4 154 69
63 35.75 0.89 20 2.56 9.6 157 71 35.2 0.85 22 2.55 9.5 156 70 33.5 0.81 22 2.51 9.3 153 69
38.00 0.86 21 2.66 9.9 168 78 37.4 0.83 22 2.64 9.9 166 77 35.6 0.79 23 2.60 9.7 163 76
67 38.19 0.72 18 2.64 9.9 166 77 37.6 0.69 19 2.62 9.8 165 77 35.7 0.66 19 2.58 9.6 162 75 40.54 0.70 18 2.74 10.3 175 83 39.9 0.67 19 2.72 10.2 174 82 37.9 0.64 20 2.68 10.1 170 81
71 40.82 0.54 14 2.72 10.2 173 82 40.2 0.52 15 2.70 10.2 172 82 38.2 0.49 15 2.66 10.0 168 80 34.76 1.00 22 2.71 10.2 166 71 34.3 0.98 24 2.70 10.1 164 70 32.5 0.94 25 2.66 9.9 161 69
59 34.17 0.98 22 2.69 10.1 164 70 33.7 0.94 23 2.68 10.0 163 70 32.0 0.90 23 2.64 9.8 159 68 35.44 0.99 23 2.77 10.4 178 75 34.9 0.95 24 2.75 10.3 177 75 33.2 0.91 25 2.71 10.2 173 73
63 34.91 0.92 21 2.75 10.3 176 75 34.4 0.88 22 2.73 10.2 175 74 32.7 0.84 22 2.69 10.1 172 73 37.11 0.89 21 2.85 10.7 188 82 36.6 0.86 23 2.84 10.7 187 82 34.7 0.82 23 2.79 10.5 183 80
67 37.30 0.75 18 2.83 10.6 186 82 36.8 0.72 19 2.81 10.6 185 81 34.9 0.69 20 2.77 10.4 181 79
75ºF
39.60 0.72 19 2.94 11.1 196 88 39.0 0.69 20 2.92 11.1 195 87 37.1 0.66 20 2.88 10.9 191 85
71 39.88 0.56 14 2.92 11.0 194 87 39.3 0.53 15 2.90 11.0 193 86 37.3 0.51 16 2.86 10.8 189 85
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
33.94 1.00 22 2.87 11.0 188 74 33.4 1.00 24 2.86 11.0 187 73 31.8 0.96 25 2.81 10.8 183 72
34.59 1.00 22 2.93 11.3 203 78 34.1 0.97 24 2.92 11.2 201 78 32.4 0.93 25 2.87 11.0 197 76
38.65 0.74 19 3.12 12.1 223 91 38.1 0.71 20 3.10 12.0 222 91 36.2 0.68 20 3.05 11.8 217 89
33.11 1.00 21 3.02 11.8 214 77 32.6 1.00 24 3.00 11.7 213 77 31.0 1.00 25 2.95 11.5 209 75
33.75 1.00 22 3.08 12.1 231 82 33.3 1.00 24 3.06 12.0 229 82 31.6 0.96 25 3.01 11.8 225 80
35.35 0.95 22 3.18 12.4 244 90 34.8 0.91 23 3.16 12.4 242 89 33.1 0.87 23 3.11 12.1 237 88
37.71 0.77 19 3.28 12.9 254 96 37.2 0.73 20 3.26 12.8 252 95 35.3 0.70 20 3.21 12.6 247 93
31.45 1.00 20 3.14 12.5 241 81 31.0 1.00 22 3.12 12.4 240 81 29.4 1.00 24 3.07 12.2 235 79
59 30.91 1.00 20 3.11 12.4 239 80 30.5 1.00 22 3.10 12.3 237 80 28.9 0.99 23 3.05 12.1 232 78 32.06 1.00 21 3.20 12.8 260 86 31.6 1.00 23 3.19 12.7 258 86 30.0 1.00 24 3.14 12.5 253 84
63 31.59 1.00 20 3.18 12.7 257 85 31.1 0.97 22 3.16 12.6 255 85 29.6 0.92 22 3.11 12.4 250 83 33.58 0.98 21 3.31 13.2 274 94 33.1 0.94 22 3.29 13.2 272 94 31.4 0.90 23 3.23 12.9 267 92
67 33.75 0.82 18 3.28 13.1 271 93 33.3 0.79 19 3.26 13.0 270 93 31.6 0.75 19 3.21 12.8 264 91
105ºF
35.82 0.80 18 3.41 13.7 286 100 35.3 0.76 19 3.39 13.6 284 100 33.5 0.73 20 3.34 13.4 278 98
71 36.08 0.61 14 3.38 13.6 283 99 35.5 0.59 15 3.37 13.5 281 99 33.8 0.56 16 3.31 13.3 275 97 29.14 1.00 19 3.24 13.2 267 84 28.7 1.00 21 3.22 13.2 265 83 27.3 1.00 22 3.17 12.9 259 82
59 28.64 1.00 18 3.22 13.1 264 83 28.2 1.00 20 3.20 13.0 262 83 26.8 0.99 22 3.15 12.8 257 81 29.70 1.00 19 3.31 13.6 287 89 29.3 1.00 21 3.29 13.5 285 89 27.8 1.00 23 3.24 13.2 279 87
63 29.26 1.00 19 3.28 13.4 284 88 28.8 0.97 20 3.27 13.4 282 88 27.4 0.93 21 3.21 13.1 276 86 31.11 0.99 20 3.42 14.0 303 97 30.6 0.95 21 3.40 13.9 301 97 29.1 0.91 22 3.34 13.7 295 95
67 31.26 0.83 17 3.39 13.9 300 97 30.8 0.79 18 3.37 13.8 298 96 29.3 0.76 18 3.32 13.6 292 94
115ºF
33.19 0.80 17 3.53 14.5 316 104 32.7 0.77 18 3.51 14.5 314 103 31.1 0.74 19 3.45 14.2 307 101
71 33.42 0.62 13 3.50 14.4 313 103 32.9 0.59 14 3.48 14.3 311 102 31.3 0.57 14 3.42 14.1 304 100
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
36.23 0.92 21 3.02 11.7 214 86 35.7 0.88 23 3.01 11.6 212 85 33.9 0.84 23 2.96 11.4 208 83
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 33.35 34.08 36.41 38.93 32.54 33.25 35.53 37.98 1.00 0.94 0.77 0.57 1.00 0.97 0.79 0.59 22 21 18 14 21 21 18 14 2.85 2.91 3.00 3.09 2.99 3.06 3.15 3.25 10.9 11.2 11.6 12.0 11.7 11.9 12.3 12.8 186 201 212 221 212 228 241 252 73 78 85 90 77 82 89 95 32.9 33.6 35.9 38.4 32.1 32.8 35.0 37.4 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 23 22 19 15 23 22 19 15 2.84 2.89 2.98 3.08 2.98 3.04 3.13 3.23 10.9 11.1 11.5 11.9 11.6 11.9 12.3 12.7 185 199 210 219 211 227 240 250 72 77 84 90 76 81 88 94 31.2 31.9 34.1 36.4 30.5 31.1 33.3 35.5 0.92 0.86 0.70 0.53 0.95 0.89 0.73 0.54 23 23 20 16 24 23 20 16 2.79 2.85 2.94 3.03 2.93 2.99 3.08 3.18 10.7 10.9 11.3 11.7 11.4 11.7 12.0 12.5 181 195 206 215 207 222 235 245 71 76 82 88 75 79 87 92
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130361A*** (CONT.)
19
20
www.goodmanmfg.com
59 39.2 0.77 16 2.84 10.6 137 60 38.1 0.73 17 2.82 10.5 136 60 35.1 0.70 17 2.76 10.2 132 58
39.86 0.87 19 2.87 10.7 139 61 38.7 0.83 20 2.84 10.6 137 60 35.7 0.80 20 2.78 10.3 133 58
Airflow MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR
MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR
41.04 0.78 17 2.92 10.9 149 65 39.8 0.74 18 2.90 10.8 148 64 36.8 0.72 18 2.84 10.5 143 62
63 40.6 0.64 14 2.90 10.8 148 64 39.4 0.61 15 2.88 10.7 146 63 36.4 0.59 15 2.82 10.4 142 62
44.42 0.59 14 3.01 11.3 157 71 43.1 0.56 15 2.98 11.2 156 70 39.8 0.54 15 2.92 10.9 151 68
67 44.5 0.44 11 2.98 11.2 156 70 43.2 0.42 11 2.96 11.1 154 69 39.9 0.41 11 2.90 10.8 150 67 47.68 0.38 10 3.10 11.7 164 75 46.3 0.36 10 3.07 11.6 163 75 42.7 0.35 10 3.00 11.3 158 72
71 38.93 0.90 19 3.07 11.5 155 64 37.8 0.86 20 3.05 11.4 154 64 34.9 0.83 20 2.98 11.1 149 62
59 38.3 0.79 17 3.05 11.4 154 64 37.2 0.76 17 3.02 11.3 152 63 34.3 0.73 18 2.96 11.0 148 61 40.09 0.81 18 3.13 11.8 167 68 38.9 0.77 18 3.11 11.7 166 68 35.9 0.74 19 3.04 11.4 161 66
63 39.7 0.66 14 3.11 11.7 166 68 38.5 0.63 15 3.08 11.6 164 67 35.6 0.61 15 3.01 11.3 159 65 43.39 0.61 14 3.22 12.2 177 75 42.1 0.58 15 3.20 12.1 175 74 38.9 0.56 15 3.13 11.7 170 72
67 43.5 0.46 11 3.20 12.1 175 74 42.2 0.44 11 3.17 11.9 173 73 39.0 0.42 12 3.10 11.6 168 71
75ºF
46.57 0.39 10 3.32 12.6 184 80 45.2 0.37 10 3.30 12.5 182 79 41.7 0.36 11 3.22 12.2 177 76
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
38.01 0.93 19 3.25 12.5 177 67 36.9 0.88 20 3.22 12.4 175 66 34.1 0.85 20 3.15 12.0 170 64
42.36 0.63 14 3.41 13.2 201 78 41.1 0.60 15 3.39 13.1 199 77 38.0 0.58 15 3.31 12.7 193 75
45.46 0.40 10 3.52 13.7 210 83 44.1 0.38 10 3.49 13.6 208 82 40.7 0.37 11 3.41 13.2 201 79
37.08 0.95 19 3.41 13.4 201 70 36.0 0.91 20 3.38 13.2 199 70 33.2 0.88 20 3.30 12.9 193 67
38.18 0.85 18 3.48 13.7 217 75 37.1 0.81 19 3.45 13.6 215 74 34.21 0.79 19 3.37 13.2 208 72
41.32 0.65 15 3.58 14.1 229 82 40.1 0.62 15 3.56 14.0 227 81 37.0 0.59 15 3.47 13.6 220 78
44.35 0.42 10 3.70 14.7 239 87 43.1 0.40 10 3.67 14.5 236 86 39.7 0.38 11 3.58 14.1 229 83
71 35.23 0.99 19 3.54 14.2 227 74 34.2 0.95 20 3.51 14.1 224 73 31.6 0.91 20 3.43 13.7 218 71
59 34.6 0.87 16 3.51 14.1 224 73 33.6 0.83 17 3.49 13.9 222 72 31.0 0.80 17 3.40 13.6 215 70 36.27 0.89 18 3.62 14.6 244 78 35.2 0.85 18 3.59 14.4 241 78 32.5 0.82 19 3.50 14.0 234 75
63 35.9 0.73 14 3.59 14.4 241 78 34.9 0.69 15 3.56 14.3 239 77 32.2 0.67 15 3.47 13.9 232 74 39.26 0.67 14 3.73 15.0 257 85 38.1 0.64 15 3.70 14.9 255 85 35.2 0.62 15 3.61 14.5 247 82
67 39.3 0.50 11 3.70 14.9 255 85 38.2 0.48 11 3.67 14.8 252 84 35.2 0.46 11 3.58 14.4 245 81
105ºF
42.13 0.43 10 3.85 15.6 269 91 40.9 0.41 10 3.82 15.5 266 90 37.8 0.40 10 3.72 15.0 258 87
71 32.63 1.00 18 3.66 15.1 250 76 31.7 0.95 19 3.63 14.9 248 75 29.2 0.92 19 3.54 14.5 240 73
59 32.1 0.88 15 3.63 14.9 248 75 31.2 0.84 16 3.60 14.8 245 75 28.8 0.81 16 3.51 14.4 238 72 33.60 0.89 16 3.73 15.4 269 81 32.6 0.85 17 3.70 15.3 267 80 30.1 0.82 17 3.62 14.9 259 78
63 33.3 0.73 13 3.70 15.3 267 80 32.3 0.70 14 3.68 15.1 264 79 29.8 0.68 14 3.59 14.7 256 77 36.36 0.68 13 3.85 15.9 285 88 35.3 0.65 14 3.82 15.8 282 88 32.6 0.62 14 3.73 15.4 273 85
67 36.4 0.51 10 3.82 15.8 282 88 35.4 0.49 11 3.79 15.6 279 87 32.7 0.47 11 3.70 15.2 270 84
115ºF
39.03 0.44 9 3.97 16.5 297 94 37.9 0.42 10 3.94 16.4 294 93 35.0 0.40 10 3.85 15.9 285 90
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
39.13 0.83 18 3.31 12.8 190 71 38.0 0.79 18 3.29 12.7 188 70 35.1 0.76 19 3.21 12.3 183 68
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 37.4 38.7 42.4 36.5 37.8 41.4 0.81 0.68 0.47 0.84 0.70 0.49 17 14 11 17 14 11 3.22 3.29 3.39 3.38 3.45 3.56 12.4 12.7 13.1 13.2 13.6 14.0 175 188 199 199 215 227 66 70 77 70 74 81 36.3 37.6 41.2 35.4 36.7 40.2 0.78 0.65 0.45 0.80 0.67 0.46 17 15 11 17 15 11 3.20 3.26 3.36 3.35 3.42 3.53 12.3 12.6 13.0 13.1 13.4 13.9 173 187 197 197 212 224 66 70 76 69 73 80 33.5 34.7 38.0 32.7 33.9 37.1 0.75 0.63 0.43 0.77 0.65 0.45 18 15 12 18 15 12 3.13 3.19 3.28 3.28 3.34 3.45 11.9 12.2 12.6 12.7 13.1 13.5 168 181 191 191 206 218 64 68 74 67 71 78
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130421A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 40.57 0.95 21 2.89 10.7 140 62 39.4 0.91 22 2.87 10.7 139 61 36.4 0.88 22 2.80 10.4 134 59
41.28 1.00 22 2.91 10.8 141 62 40.1 0.95 23 2.89 10.7 140 62 37.0 0.92 24 2.82 10.5 136 60
Airflow MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR
MBh S/T ∆T 1688 kW Amps HI PR LO PR MBh S/T ∆T 1500 kW Amps HI PR LO PR MBh S/T ∆T 1313 kW Amps HI PR LO PR
42.08 0.97 22 2.96 11.1 152 66 40.9 0.92 23 2.94 11.0 151 65 37.7 0.89 23 2.88 10.7 146 63
63 41.46 0.90 20 2.94 11.0 151 65 40.2 0.85 21 2.92 10.9 149 65 37.1 0.82 21 2.86 10.6 145 63
44.07 0.87 21 3.05 11.5 161 72 42.8 0.83 22 3.03 11.4 159 71 39.5 0.80 22 2.96 11.1 154 69
67 44.29 0.73 18 3.03 11.4 159 71 43.0 0.70 18 3.01 11.3 157 71 39.7 0.67 19 2.94 11.0 153 69 47.01 0.71 18 3.14 11.9 168 77 45.6 0.67 19 3.12 11.8 166 76 42.1 0.65 19 3.05 11.5 161 74
71 47.35 0.54 14 3.12 11.8 166 76 46.0 0.52 15 3.10 11.7 164 75 42.4 0.50 15 3.03 11.4 159 73 40.32 1.00 22 3.12 11.7 159 66 39.1 0.99 24 3.09 11.6 157 65 36.1 0.95 24 3.02 11.3 152 63
59 39.63 1.00 22 3.09 11.6 157 65 38.5 0.94 22 3.07 11.5 156 64 35.5 0.91 23 3.00 11.2 151 62 41.10 1.00 22 3.18 12.0 171 70 39.9 0.95 23 3.15 11.9 169 69 36.8 0.92 24 3.08 11.6 164 67
63 40.49 0.93 20 3.15 11.9 169 69 39.3 0.89 21 3.13 11.8 167 68 36.3 0.85 22 3.06 11.5 162 66 43.04 0.90 21 3.27 12.4 180 76 41.8 0.86 22 3.25 12.3 178 75 38.6 0.83 22 3.17 11.9 173 73
67 43.26 0.76 18 3.25 12.3 178 75 42.0 0.72 19 3.22 12.2 177 75 38.8 0.69 19 3.15 11.8 171 72
75ºF
45.92 0.73 18 3.37 12.9 188 81 44.6 0.70 19 3.35 12.7 186 80 41.2 0.67 19 3.27 12.4 181 78
71 46.24 0.56 14 3.35 12.7 186 80 44.9 0.54 15 3.32 12.6 184 80 41.4 0.52 15 3.25 12.3 179 77
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
39.36 1.00 21 3.30 12.7 180 68 38.2 1.00 23 3.27 12.6 179 68 35.3 0.98 24 3.20 12.3 173 66
40.12 1.00 22 3.37 13.0 194 73 39.0 0.98 23 3.34 12.9 192 72 36.0 0.94 24 3.26 12.6 186 70
44.83 0.75 18 3.58 14.0 214 84 43.5 0.72 19 3.55 13.8 212 84 40.2 0.69 19 3.47 13.5 205 81
38.40 1.00 21 3.46 13.6 205 72 37.3 1.00 23 3.43 13.5 203 71 34.4 1.00 24 3.35 13.1 197 69
39.14 1.00 21 3.53 13.9 221 76 38.0 1.00 23 3.50 13.8 219 75 35.1 0.97 24 3.42 13.4 212 73
40.99 0.96 21 3.64 14.4 234 83 39.8 0.91 22 3.61 14.3 231 82 36.7 0.88 23 3.53 13.9 224 80
43.73 0.78 18 3.76 14.9 244 89 42.5 0.74 19 3.73 14.8 241 88 39.2 0.71 20 3.64 14.4 234 85
36.48 1.00 20 3.60 14.5 231 75 35.4 1.00 22 3.57 14.3 229 74 32.7 1.00 23 3.49 13.9 222 72
59 35.85 1.00 20 3.57 14.3 229 74 34.8 1.00 21 3.54 14.2 227 74 32.1 1.00 22 3.46 13.8 220 71 37.18 1.00 20 3.67 14.8 249 80 36.1 1.00 22 3.64 14.7 246 79 33.3 1.00 23 3.56 14.3 239 77
63 36.64 1.00 20 3.64 14.7 246 79 35.6 0.97 21 3.62 14.6 244 78 32.8 0.94 22 3.53 14.2 237 76 38.94 0.99 21 3.79 15.3 263 87 37.8 0.95 22 3.76 15.2 260 86 34.9 0.91 22 3.67 14.8 252 84
67 39.14 0.83 18 3.76 15.2 260 86 38.0 0.79 18 3.73 15.0 258 85 35.1 0.76 19 3.64 14.6 250 83
105ºF
41.55 0.81 18 3.91 15.9 274 93 40.3 0.77 19 3.88 15.8 271 92 37.2 0.74 19 3.78 15.3 263 89
71 41.84 0.62 14 3.88 15.8 271 92 40.6 0.59 15 3.85 15.6 269 91 37.5 0.57 15 3.75 15.2 261 88 33.79 1.00 18 3.72 15.3 255 78 32.8 1.00 20 3.69 15.2 253 77 30.3 1.00 21 3.60 14.8 245 75
59 33.21 1.00 18 3.69 15.2 253 77 32.2 1.00 20 3.66 15.1 250 76 29.8 1.01 21 3.57 14.6 243 74 34.44 1.00 19 3.79 15.7 275 83 33.4 1.00 20 3.76 15.6 272 82 30.9 1.00 22 3.67 15.1 264 79
63 33.94 1.00 18 3.76 15.6 272 82 32.9 0.98 20 3.73 15.4 269 81 30.4 0.95 20 3.65 15.0 261 79 36.07 1.00 20 3.91 16.2 290 90 35.0 0.95 20 3.88 16.1 287 89 32.3 0.92 21 3.79 15.6 279 87
67 36.26 0.84 17 3.88 16.1 287 89 35.2 0.80 17 3.85 15.9 285 88 32.5 0.77 18 3.76 15.5 276 86
115ºF
38.49 0.81 17 4.04 16.9 303 96 37.4 0.77 18 4.01 16.7 300 95 34.5 0.75 18 3.91 16.2 291 92
71 38.76 0.63 13 4.01 16.7 300 95 37.6 0.60 14 3.98 16.5 297 94 34.7 0.58 14 3.88 16.1 288 91
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
42.02 0.93 21 3.47 13.5 205 79 40.8 0.88 22 3.44 13.3 203 78 37.7 0.85 22 3.36 13.0 197 76
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 38.68 39.53 42.23 45.14 37.74 38.56 41.20 44.04 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 21 20 18 14 21 21 18 14 3.27 3.34 3.44 3.55 3.43 3.50 3.61 3.73 12.6 12.9 13.3 13.8 13.5 13.8 14.3 14.8 179 192 203 212 203 219 231 241 68 72 78 84 71 75 82 88 37.6 38.4 41.0 43.8 36.6 37.4 40.0 42.8 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 22 21 19 15 22 21 19 15 3.25 3.31 3.42 3.52 3.41 3.48 3.58 3.70 12.5 12.8 13.2 13.7 13.4 13.7 14.1 14.7 177 190 201 210 201 217 229 239 67 71 78 83 70 75 82 87 34.7 35.4 37.8 40.5 33.8 34.6 36.9 39.5 0.93 0.88 0.71 0.53 0.96 0.90 0.74 0.55 23 22 19 15 23 22 19 15 3.17 3.24 3.34 3.44 3.33 3.40 3.50 3.61 12.2 12.4 12.9 13.3 13.0 13.3 13.7 14.3 172 185 195 203 195 210 222 232 65 69 75 80 68 72 79 84
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130421A*** (CONT.)
21
22
www.goodmanmfg.com
59 44.1 0.76 17 3.22 12.1 142 64 42.8 0.72 18 3.20 12.0 141 63 39.5 0.70 18 3.13 11.7 136 61
44.84 0.86 20 3.24 12.2 144 65 43.5 0.82 21 3.22 12.1 142 64 40.2 0.79 21 3.15 11.8 138 62
Airflow MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR
MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR
46.17 0.77 18 3.30 12.5 154 69 44.8 0.74 19 3.28 12.4 153 68 41.4 0.71 19 3.21 12.0 148 66
63 45.7 0.63 15 3.28 12.4 153 68 44.4 0.60 15 3.26 12.3 151 67 41.0 0.58 16 3.19 11.9 147 65
49.98 0.58 15 3.40 12.9 163 75 48.5 0.56 16 3.37 12.8 162 74 44.8 0.54 16 3.30 12.4 157 72
67 50.1 0.44 11 3.37 12.8 161 74 48.6 0.42 12 3.35 12.7 160 73 44.9 0.40 12 3.28 12.3 155 71 53.64 0.38 10 3.50 13.4 170 80 52.1 0.36 11 3.47 13.2 168 79 48.1 0.35 11 3.40 12.9 163 77
71 43.80 0.89 20 3.47 13.2 161 68 42.5 0.85 21 3.44 13.0 159 68 39.3 0.82 21 3.37 12.7 155 65
59 43.1 0.79 17 3.44 13.0 159 67 41.8 0.75 18 3.42 12.9 158 67 38.6 0.72 18 3.34 12.6 153 65 45.10 0.80 18 3.54 13.5 173 73 43.8 0.76 19 3.51 13.4 172 72 40.4 0.74 20 3.43 13.0 166 70
63 44.6 0.66 15 3.51 13.4 172 72 43.3 0.63 16 3.48 13.2 170 71 40.0 0.60 16 3.41 12.9 165 69 48.81 0.61 15 3.64 13.9 183 79 47.4 0.58 16 3.61 13.8 181 78 43.7 0.56 16 3.53 13.4 176 76
67 48.9 0.46 11 3.61 13.8 181 78 47.5 0.43 12 3.58 13.7 179 78 43.8 0.42 12 3.50 13.3 174 75
75ºF
52.39 0.39 10 3.75 14.4 191 84 50.9 0.37 11 3.72 14.3 189 83 46.9 0.36 11 3.64 13.9 183 81
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
42.76 0.92 20 3.67 14.3 183 71 41.5 0.87 21 3.64 14.2 181 70 38.3 0.84 21 3.56 13.8 176 68
47.65 0.62 15 3.85 15.1 208 82 46.3 0.59 16 3.82 15.0 206 81 42.7 0.57 16 3.74 14.6 200 79
51.14 0.40 10 3.97 15.7 217 88 49.7 0.38 11 3.94 15.5 215 87 45.8 0.37 11 3.85 15.1 209 84
41.72 0.95 20 3.84 15.3 209 74 40.5 0.90 21 3.81 15.1 207 74 37.4 0.87 21 3.73 14.7 200 71
42.95 0.85 19 3.92 15.6 225 79 41.7 0.81 19 3.89 15.5 222 78 38.49 0.78 20 3.80 15.1 216 76
46.49 0.64 15 4.04 16.2 237 86 45.1 0.61 16 4.01 16.0 235 86 41.7 0.59 16 3.92 15.6 228 83
49.89 0.41 11 4.16 16.8 247 92 48.4 0.39 11 4.13 16.6 245 91 44.7 0.38 11 4.04 16.2 238 88
71 39.63 0.98 20 3.99 16.2 235 78 38.5 0.94 21 3.96 16.1 232 77 35.5 0.90 21 3.87 15.7 225 75
59 39.0 0.86 17 3.96 16.1 232 77 37.8 0.82 18 3.93 16.0 230 76 34.9 0.79 18 3.84 15.5 223 74 40.80 0.88 18 4.07 16.6 253 83 39.6 0.84 19 4.04 16.5 250 82 36.6 0.81 19 3.95 16.0 243 80
63 40.4 0.72 15 4.04 16.5 250 82 39.2 0.69 16 4.01 16.3 248 81 36.2 0.66 16 3.92 15.9 240 79 44.16 0.66 15 4.20 17.2 267 91 42.9 0.63 16 4.17 17.0 264 90 39.6 0.61 16 4.07 16.6 256 87
67 44.3 0.50 11 4.17 17.0 264 90 43.0 0.48 12 4.13 16.9 261 89 39.7 0.46 12 4.04 16.4 254 86
105ºF
47.40 0.43 10 4.33 17.9 278 96 46.0 0.41 11 4.30 17.7 275 96 42.5 0.39 11 4.20 17.2 267 93
71 36.71 0.99 19 4.12 17.2 259 81 35.6 0.94 19 4.09 17.1 257 80 32.9 0.91 20 3.99 16.6 249 77
59 36.1 0.87 16 4.09 17.1 257 80 35.0 0.83 17 4.06 16.9 254 79 32.3 0.80 17 3.96 16.4 247 77 37.80 0.89 17 4.21 17.6 279 86 36.7 0.84 18 4.17 17.5 276 85 33.9 0.81 18 4.08 17.0 268 82
63 37.4 0.73 14 4.17 17.5 276 85 36.3 0.69 14 4.14 17.3 274 84 33.5 0.67 15 4.04 16.8 265 82 40.91 0.67 14 4.34 18.2 295 94 39.7 0.64 15 4.30 18.1 292 93 36.7 0.62 15 4.20 17.6 283 90
67 41.0 0.50 11 4.30 18.1 292 93 39.8 0.48 11 4.27 17.9 289 92 36.7 0.46 11 4.17 17.4 280 89
115ºF
43.91 0.43 10 4.47 18.9 307 100 42.6 0.41 10 4.44 18.7 304 99 39.3 0.40 10 4.33 18.2 295 96
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
44.02 0.82 18 3.74 14.6 197 75 42.7 0.78 19 3.71 14.5 195 75 39.5 0.75 20 3.63 14.1 189 72
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 42.0 43.6 47.7 41.0 42.5 46.6 0.81 0.67 0.47 0.83 0.70 0.48 17 15 11 17 15 11 3.64 3.71 3.82 3.81 3.89 4.01 14.2 14.5 15.0 15.1 15.5 16.0 181 195 206 207 222 235 70 75 81 74 78 86 40.8 42.3 46.4 39.8 41.3 45.2 0.77 0.64 0.45 0.79 0.66 0.46 18 16 12 18 16 12 3.61 3.68 3.79 3.78 3.86 3.98 14.0 14.4 14.8 15.0 15.4 15.9 180 193 204 205 220 232 69 74 81 73 78 85 37.7 39.1 42.8 36.8 38.1 41.7 0.74 0.62 0.43 0.77 0.64 0.44 18 16 12 18 16 12 3.53 3.60 3.71 3.70 3.77 3.89 13.7 14.0 14.4 14.6 14.9 15.4 174 187 198 198 213 225 67 72 78 71 75 82
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130481A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 45.64 0.95 22 3.27 12.3 145 65 44.3 0.90 23 3.24 12.2 144 65 40.9 0.87 23 3.17 11.9 139 63
46.44 0.99 24 3.29 12.4 146 66 45.1 0.95 25 3.27 12.3 145 65 41.6 0.91 25 3.19 12.0 141 63
Airflow MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR
MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1600 kW Amps HI PR LO PR MBh S/T ∆T 1400 kW Amps HI PR LO PR
47.34 0.96 23 3.35 12.7 158 70 46.0 0.91 24 3.33 12.6 156 69 42.4 0.88 25 3.26 12.3 151 67
63 46.64 0.89 21 3.33 12.6 156 69 45.3 0.85 22 3.30 12.5 155 69 41.8 0.82 22 3.23 12.1 150 67
49.58 0.86 22 3.45 13.1 166 76 48.1 0.82 23 3.42 13.0 165 76 44.4 0.79 23 3.35 12.6 160 73
67 49.83 0.72 18 3.42 13.0 165 76 48.4 0.69 19 3.40 12.9 163 75 44.7 0.66 19 3.32 12.5 158 73 52.89 0.70 19 3.55 13.6 174 81 51.4 0.67 20 3.52 13.5 172 81 47.4 0.64 20 3.45 13.1 167 78
71 53.26 0.54 15 3.52 13.5 172 81 51.7 0.51 15 3.50 13.4 170 80 47.7 0.50 16 3.42 13.0 165 77 45.36 1.00 23 3.52 13.4 164 70 44.0 0.98 25 3.49 13.3 163 69 40.6 0.95 25 3.42 12.9 158 67
59 44.58 1.00 23 3.49 13.3 163 69 43.3 0.94 23 3.47 13.2 161 68 39.9 0.90 24 3.39 12.8 156 66 46.24 0.99 23 3.59 13.7 177 74 44.9 0.95 24 3.56 13.6 175 73 41.4 0.91 25 3.48 13.2 170 71
63 45.55 0.92 21 3.56 13.6 175 73 44.2 0.88 22 3.54 13.5 173 73 40.8 0.85 23 3.46 13.1 168 70 48.42 0.90 22 3.69 14.2 187 81 47.0 0.85 23 3.67 14.0 185 80 43.4 0.82 23 3.58 13.7 179 78
67 48.67 0.75 19 3.67 14.0 185 80 47.3 0.71 19 3.64 13.9 183 79 43.6 0.69 20 3.56 13.5 178 77
75ºF
51.66 0.73 19 3.81 14.7 195 86 50.2 0.69 20 3.78 14.6 193 85 46.3 0.67 20 3.69 14.2 187 83
71 52.03 0.56 15 3.78 14.6 193 85 50.5 0.53 15 3.75 14.4 191 84 46.6 0.51 16 3.66 14.0 185 82
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
44.28 1.00 23 3.72 14.6 187 72 43.0 1.00 25 3.69 14.4 185 72 39.7 0.97 25 3.61 14.0 180 69
45.14 1.00 23 3.80 14.9 201 77 43.8 0.97 24 3.77 14.8 199 76 40.4 0.94 25 3.68 14.4 193 74
50.43 0.74 19 4.03 16.0 222 89 49.0 0.71 20 4.00 15.8 219 89 45.2 0.68 20 3.91 15.4 213 86
43.20 1.00 22 3.90 15.6 213 76 41.9 1.00 24 3.87 15.4 211 75 38.7 1.00 25 3.78 15.0 204 73
44.03 1.00 22 3.98 15.9 229 81 42.8 1.00 25 3.95 15.8 227 80 39.5 0.97 25 3.86 15.4 220 78
46.12 0.95 22 4.10 16.5 242 88 44.8 0.90 23 4.07 16.3 240 87 41.3 0.87 24 3.98 15.9 232 85
49.20 0.77 19 4.23 17.1 252 94 47.8 0.73 20 4.20 16.9 250 93 44.1 0.71 20 4.10 16.5 242 90
41.04 1.00 21 4.05 16.6 239 80 39.8 1.00 23 4.02 16.4 237 79 36.8 1.00 24 3.93 15.9 230 76
59 40.33 1.00 21 4.02 16.4 237 79 39.2 1.00 23 3.99 16.3 235 78 36.1 0.99 24 3.90 15.8 228 76 41.83 1.00 21 4.14 17.0 258 85 40.6 1.00 23 4.11 16.8 255 84 37.5 1.00 25 4.01 16.3 248 81
63 41.21 1.00 21 4.11 16.8 255 84 40.0 0.96 22 4.07 16.6 253 83 36.9 0.93 23 3.98 16.2 245 81 43.81 0.98 22 4.27 17.5 272 92 42.5 0.94 23 4.23 17.4 269 92 39.3 0.90 23 4.13 16.9 261 89
67 44.03 0.82 18 4.23 17.4 269 92 42.8 0.78 19 4.20 17.2 267 91 39.5 0.76 20 4.10 16.7 259 88
105ºF
46.74 0.80 19 4.40 18.2 284 98 45.4 0.76 20 4.37 18.0 281 97 41.9 0.73 20 4.26 17.5 273 95
71 47.07 0.61 15 4.37 18.0 281 97 45.7 0.59 15 4.33 17.9 278 96 42.2 0.57 16 4.23 17.4 270 94 38.01 1.00 19 4.19 17.5 265 82 36.9 1.00 21 4.15 17.4 262 81 34.1 1.00 22 4.06 16.9 254 79
59 37.36 1.00 19 4.15 17.4 262 81 36.3 1.00 21 4.12 17.2 259 81 33.5 1.00 22 4.03 16.7 252 78 38.75 1.00 20 4.27 18.0 285 88 37.6 1.00 22 4.24 17.8 282 87 34.7 1.00 23 4.14 17.3 273 84
63 38.18 1.00 19 4.24 17.8 282 87 37.1 0.97 21 4.21 17.6 279 86 34.2 0.94 21 4.11 17.1 271 83 40.58 0.99 21 4.41 18.6 301 96 39.4 0.95 21 4.37 18.4 298 95 36.4 0.91 22 4.27 17.9 289 92
67 40.79 0.83 17 4.37 18.4 298 95 39.6 0.79 18 4.34 18.2 295 94 36.6 0.76 18 4.23 17.7 286 91
115ºF
43.30 0.80 18 4.55 19.3 314 102 42.0 0.77 19 4.51 19.1 311 101 38.8 0.74 19 4.40 18.6 301 98
71 43.60 0.62 14 4.51 19.1 311 101 42.3 0.59 14 4.47 18.9 307 100 39.1 0.57 15 4.37 18.4 298 97
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
47.27 0.92 22 3.91 15.4 212 84 45.9 0.88 23 3.88 15.3 210 83 42.4 0.84 23 3.79 14.8 204 81
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 43.52 44.47 47.51 50.79 42.46 43.38 46.35 49.55 1.00 0.94 0.77 0.57 1.00 1.00 0.79 0.59 22 21 19 15 22 22 19 15 3.69 3.77 3.88 4.00 3.87 3.95 4.07 4.20 14.4 14.8 15.3 15.8 15.4 15.8 16.3 16.9 185 199 210 219 211 227 240 250 72 76 83 89 75 80 87 93 42.3 43.2 46.1 49.3 41.2 42.1 40.0 48.1 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.56 23 22 19 16 23 22 19 16 3.67 3.74 3.85 3.97 3.84 3.92 3.58 4.17 14.3 14.6 15.1 15.7 15.3 15.6 14.1 16.8 183 197 208 217 209 225 229 247 71 75 82 88 74 79 82 92 39.0 39.8 42.6 45.5 38.0 38.9 41.5 44.4 0.92 0.87 0.71 0.53 0.95 0.90 0.73 0.54 24 23 20 16 24 23 20 16 3.58 3.66 3.76 3.88 3.75 3.83 3.95 4.07 13.9 14.2 14.7 15.3 14.9 15.2 15.7 16.3 178 191 202 211 202 218 230 240 69 73 80 85 72 77 84 89
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130481A*** (CONT.)
23
24
www.goodmanmfg.com
59 54.4 0.72 18 3.84 13.8 140 59 52.8 0.69 19 3.81 13.7 139 58 48.7 0.67 19 3.73 13.3 135 56
55.31 0.82 21 3.87 13.9 142 59 53.7 0.78 22 3.84 13.8 140 59 49.6 0.76 22 3.76 13.4 136 57
Airflow MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR
MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR
56.94 0.74 19 3.95 14.2 153 63 55.3 0.70 20 3.92 14.1 151 63 51.0 0.68 20 3.83 13.7 147 61
63 56.4 0.60 15 3.92 14.1 151 63 54.7 0.58 16 3.89 14.0 150 62 50.5 0.56 16 3.80 13.6 145 60
61.64 0.56 16 4.06 14.7 161 69 59.8 0.53 16 4.03 14.6 160 68 55.2 0.51 17 3.94 14.2 155 66
67 61.8 0.42 12 4.03 14.6 159 68 60.0 0.40 12 4.00 14.4 158 68 55.3 0.39 12 3.91 14.0 153 66 66.15 0.36 11 4.18 15.2 168 73 64.2 0.34 11 4.15 15.1 166 73 59.3 0.33 11 4.06 14.7 161 71
71 54.02 0.85 21 4.15 15.0 159 63 52.4 0.81 22 4.12 14.9 158 62 48.4 0.78 22 4.02 14.5 153 60
59 53.1 0.75 18 4.12 14.9 157 62 51.6 0.72 19 4.09 14.8 156 61 47.6 0.69 19 3.99 14.4 151 60 55.62 0.76 19 4.23 15.4 171 67 54.0 0.73 20 4.20 15.2 170 66 49.8 0.70 20 4.10 14.8 164 64
63 55.1 0.63 16 4.20 15.2 169 66 53.5 0.60 16 4.17 15.1 168 65 49.3 0.58 17 4.07 14.7 163 63 60.20 0.58 16 4.36 15.9 181 73 58.4 0.55 16 4.32 15.7 179 72 53.9 0.53 17 4.23 15.3 174 70
67 60.3 0.43 12 4.32 15.7 179 72 58.6 0.41 12 4.29 15.6 177 71 54.1 0.40 13 4.19 15.2 172 69
75ºF
64.61 0.37 11 4.49 16.5 189 78 62.7 0.35 11 4.46 16.3 187 77 57.9 0.34 12 4.35 15.9 181 74
71 -
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
75
70
IDB
65ºF
52.73 0.87 21 4.39 16.3 181 65 51.2 0.83 22 4.36 16.2 179 65 47.3 0.80 22 4.26 15.7 174 63
58.77 0.59 16 4.62 17.3 206 76 57.1 0.56 16 4.58 17.1 204 75 52.7 0.54 17 4.48 16.6 197 73
63.08 0.38 11 4.76 17.9 214 81 61.2 0.36 11 4.73 17.8 212 80 56.5 0.35 12 4.61 17.3 206 77
51.45 0.90 21 4.61 17.4 206 68 50.0 0.86 22 4.57 17.3 204 68 46.1 0.83 22 4.46 16.8 198 66
52.97 0.81 19 4.70 17.9 222 73 51.4 0.77 20 4.67 17.7 220 72 47.47 0.74 21 4.56 17.2 213 70
57.34 0.61 16 4.85 18.5 234 80 55.7 0.58 17 4.81 18.3 232 79 51.4 0.56 17 4.70 17.8 225 76
61.54 0.39 11 5.00 19.2 244 85 59.7 0.37 11 4.96 19.0 242 84 55.1 0.36 12 4.84 18.5 235 81
71 48.88 0.94 21 4.79 18.6 232 72 47.5 0.89 22 4.75 18.4 230 71 43.8 0.86 22 4.64 17.9 223 69
59 48.1 0.82 18 4.75 18.4 229 71 46.7 0.79 19 4.72 18.2 227 70 43.1 0.76 19 4.60 17.7 220 68 50.32 0.84 19 4.89 19.0 249 76 48.9 0.80 20 4.85 18.8 247 76 45.1 0.77 20 4.74 18.3 240 73
63 49.8 0.69 16 4.85 18.8 247 76 48.4 0.66 16 4.81 18.7 245 75 44.6 0.63 16 4.70 18.2 237 73 54.47 0.63 16 5.04 19.7 263 83 52.9 0.60 16 5.00 19.5 261 82 48.8 0.58 17 4.88 18.9 253 80
67 54.6 0.48 12 5.00 19.5 261 82 53.0 0.45 12 4.96 19.3 258 82 48.9 0.44 13 4.85 18.8 250 79
105ºF
58.46 0.41 11 5.21 20.4 275 89 56.8 0.39 11 5.16 20.2 272 88 52.4 0.38 11 5.04 19.7 264 85
71 45.27 0.94 19 4.95 19.7 256 74 44.0 0.90 20 4.91 19.5 254 73 40.6 0.87 21 4.79 19.0 246 71
59 44.5 0.83 17 4.91 19.5 254 73 43.2 0.79 17 4.87 19.3 251 73 39.9 0.76 18 4.75 18.8 244 71 46.61 0.84 18 5.05 20.2 276 79 45.3 0.81 19 5.01 20.0 273 78 41.8 0.78 19 4.89 19.4 265 76
63 46.1 0.69 15 5.01 20.0 273 78 44.8 0.66 15 4.97 19.8 270 77 41.4 0.64 15 4.85 19.2 262 75 50.46 0.64 15 5.21 20.8 291 86 49.0 0.61 15 5.17 20.6 288 85 45.2 0.59 16 5.05 20.1 280 83
67 50.6 0.48 11 5.17 20.6 288 85 49.1 0.46 11 5.13 20.5 285 84 45.3 0.44 12 5.01 19.9 277 82
115ºF
54.15 0.41 10 5.38 21.6 304 92 52.6 0.39 11 5.34 21.4 301 91 48.5 0.38 11 5.21 20.8 292 88
71 -
Shaded area reflects ACCA (TVA) conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
54.30 0.78 19 4.48 16.7 195 69 52.7 0.75 20 4.45 16.6 193 69 48.7 0.72 20 4.34 16.1 187 67
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 51.9 53.7 58.9 50.6 52.4 57.5 0.77 0.64 0.45 0.79 0.66 0.46 18 16 12 18 16 12 4.36 4.45 4.58 4.57 4.67 4.81 16.2 16.6 17.1 17.3 17.7 18.3 179 193 204 204 220 232 65 69 75 68 72 79 50.3 52.2 57.2 49.1 50.9 55.8 0.73 0.61 0.42 0.76 0.63 0.44 19 16 12 19 16 12 4.32 4.41 4.55 4.54 4.63 4.77 16.0 16.4 17.0 17.1 17.5 18.1 177 191 202 202 217 230 64 68 74 67 71 78 46.5 48.2 52.8 45.3 47.0 51.5 0.71 0.59 0.41 0.73 0.61 0.42 19 17 13 19 17 13 4.23 4.31 4.44 4.43 4.52 4.66 15.6 16.0 16.5 16.7 17.1 17.6 172 185 195 196 211 223 62 66 72 65 69 76
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130601A***
SS-VSH13
SS-VSH13
www.goodmanmfg.com
59 56.29 0.90 23 3.90 14.0 143 60 54.7 0.86 24 3.87 13.9 142 59 50.4 0.83 24 3.79 13.5 138 58
57.27 0.95 25 3.93 14.2 145 61 55.6 0.90 26 3.90 14.0 143 60 51.3 0.87 26 3.81 13.6 139 58
Airflow MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR
MBh S/T ∆T 2025 kW Amps HI PR LO PR MBh S/T ∆T 1800 kW Amps HI PR LO PR MBh S/T ∆T 1575 kW Amps HI PR LO PR
58.38 0.91 24 4.01 14.5 156 64 56.7 0.87 25 3.98 14.4 154 64 52.3 0.84 26 3.89 14.0 149 62
63 57.52 0.85 22 3.98 14.4 154 64 55.8 0.81 23 3.95 14.2 153 63 51.5 0.78 23 3.86 13.8 148 61
61.15 0.82 23 4.12 15.0 164 70 59.4 0.79 24 4.09 14.8 163 70 54.8 0.76 24 4.00 14.4 158 68
67 61.45 0.69 19 4.09 14.8 163 70 59.7 0.66 20 4.06 14.7 161 69 55.1 0.63 20 3.97 14.3 156 67 65.23 0.67 20 4.25 15.5 171 75 63.3 0.64 21 4.22 15.4 170 74 58.5 0.61 21 4.12 15.0 165 72
71 65.69 0.51 15 4.22 15.4 170 74 63.8 0.49 16 4.19 15.2 168 73 58.9 0.47 16 4.09 14.8 163 71 55.94 0.98 25 4.21 15.3 162 64 54.3 0.94 26 4.18 15.2 161 63 50.1 0.90 26 4.08 14.7 156 61
59 54.98 0.94 23 4.18 15.2 161 63 53.4 0.89 24 4.15 15.0 159 63 49.3 0.86 25 4.05 14.6 154 61 57.02 0.95 24 4.30 15.7 175 68 55.4 0.90 26 4.26 15.5 173 67 51.1 0.87 26 4.17 15.1 168 65
63 56.18 0.88 22 4.26 15.5 173 67 54.5 0.84 23 4.23 15.4 171 67 50.3 0.81 24 4.13 15.0 166 65 59.72 0.85 23 4.43 16.2 184 74 58.0 0.81 24 4.39 16.0 183 74 53.5 0.79 25 4.29 15.6 177 71
67 60.02 0.71 19 4.39 16.0 183 74 58.3 0.68 20 4.36 15.9 181 73 53.8 0.66 21 4.26 15.5 175 71
75ºF
63.72 0.69 20 4.56 16.8 192 79 61.9 0.66 21 4.53 16.6 190 78 57.1 0.64 21 4.42 16.2 185 76
71 64.16 0.53 16 4.53 16.6 190 78 62.3 0.51 16 4.49 16.5 189 78 57.5 0.49 16 4.39 16.0 183 75
IDB: Entering Indoor Dry Bulb Temperature kW=Total system power High and low pressures are measured at the liquid and suction service valves.
85
80
IDB
65ºF
54.61 1.00 25 4.46 16.6 185 66 53.0 0.96 26 4.43 16.5 183 66 48.9 0.92 26 4.32 16.0 177 64
55.67 0.97 25 4.55 17.0 199 71 54.0 0.93 26 4.52 16.9 197 70 49.9 0.89 26 4.41 16.4 191 68
62.20 0.71 20 4.84 18.3 219 82 60.4 0.68 21 4.80 18.1 217 81 55.7 0.65 21 4.69 17.6 210 79
53.28 1.00 24 4.68 17.8 210 70 51.7 0.99 26 4.64 17.6 208 69 47.7 0.95 27 4.53 17.1 202 67
54.31 1.00 25 4.78 18.2 226 74 52.7 0.96 26 4.74 18.0 224 74 48.7 0.92 26 4.63 17.5 217 71
56.88 0.90 23 4.93 18.8 239 81 55.2 0.86 24 4.89 18.6 237 80 51.0 0.83 25 4.77 18.1 229 78
60.68 0.73 20 5.08 19.5 249 86 58.9 0.70 21 5.04 19.3 247 86 54.4 0.67 21 4.92 18.8 239 83
50.61 1.00 23 4.87 18.9 237 73 49.1 1.00 25 4.83 18.7 234 72 45.4 0.99 26 4.71 18.2 227 70
59 49.74 1.00 23 4.83 18.7 234 72 48.3 0.98 24 4.79 18.6 232 72 44.6 0.94 25 4.68 18.1 225 70 51.59 1.00 23 4.97 19.4 255 78 50.1 0.99 25 4.93 19.2 252 77 46.2 0.96 26 4.81 18.7 244 75
63 50.83 0.96 22 4.93 19.2 252 77 49.4 0.92 23 4.89 19.0 250 76 45.6 0.89 24 4.78 18.5 242 74 54.04 0.94 23 5.13 20.0 269 85 52.5 0.89 24 5.09 19.8 266 84 48.4 0.86 24 4.96 19.3 258 82
67 54.31 0.78 19 5.09 19.8 266 84 52.7 0.75 20 5.04 19.7 263 83 48.7 0.72 20 4.92 19.1 256 81
105ºF
57.65 0.76 20 5.29 20.8 280 91 56.0 0.73 21 5.25 20.6 278 90 51.7 0.70 21 5.12 20.0 269 87
71 58.05 0.59 15 5.25 20.6 278 90 56.4 0.56 16 5.21 20.4 275 89 52.0 0.54 16 5.08 19.8 267 86 46.88 1.00 21 5.03 20.0 261 76 45.5 1.00 23 4.99 19.9 259 75 42.0 1.00 24 4.87 19.3 251 73
59 46.08 1.00 21 4.99 19.9 259 75 44.7 0.99 23 4.95 19.7 256 74 41.3 0.95 23 4.83 19.1 248 72 47.79 1.00 22 5.14 20.5 281 81 46.4 1.00 24 5.09 20.3 278 80 42.8 0.96 24 4.97 19.8 270 77
63 47.09 1.00 21 5.09 20.3 278 80 45.7 0.93 22 5.05 20.2 276 79 42.2 0.89 22 4.93 19.6 267 77 50.05 0.95 21 5.30 21.2 297 88 48.6 0.90 22 5.26 21.0 294 87 44.9 0.87 23 5.13 20.4 285 84
67 50.31 0.79 18 5.26 21.0 294 87 48.8 0.75 19 5.21 20.8 291 86 45.1 0.73 19 5.09 20.3 282 84
115ºF
53.40 0.77 19 5.47 22.0 310 94 51.8 0.73 19 5.43 21.8 307 93 47.9 0.71 20 5.29 21.2 297 90
71 53.78 0.59 14 5.43 21.8 307 93 52.2 0.56 15 5.38 21.6 304 92 48.2 0.54 15 5.25 21.0 295 89
Shaded area reflects ARI conditions Amps = outdoor unit amps (comp.+fan) Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test conditions
58.30 0.88 23 4.69 17.6 210 77 56.6 0.84 24 4.66 17.4 208 76 52.2 0.81 25 4.55 17.0 201 74
Outdoor Ambient Temperature 85ºF 95ºF Entering Indoor Wet Bulb Temperature 59 63 67 71 59 63 67 71 53.67 54.84 58.59 62.64 52.36 53.51 57.17 61.11 0.96 0.90 0.73 0.55 1.00 0.93 0.76 0.56 23 22 19 16 24 23 20 16 4.43 4.52 4.66 4.80 4.64 4.74 4.89 5.04 16.5 16.9 17.4 18.1 17.6 18.0 18.6 19.3 183 197 208 217 208 224 237 247 66 70 76 81 69 74 80 86 52.1 53.2 56.9 60.8 50.8 51.9 55.5 59.3 0.91 0.86 0.70 0.52 0.94 0.89 0.72 0.54 24 23 20 16 25 23 20 16 4.39 4.48 4.62 4.76 4.61 4.70 4.85 5.00 16.3 16.7 17.3 17.9 17.4 17.9 18.5 19.2 181 195 206 214 206 222 234 244 65 69 76 81 68 73 80 85 48.1 49.1 52.5 56.1 46.9 47.9 51.2 54.8 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.52 25 24 21 16 25 24 21 17 4.29 4.38 4.51 4.65 4.50 4.59 4.73 4.88 15.9 16.3 16.8 17.4 17.0 17.4 18.0 18.6 176 189 199 208 200 215 227 237 63 67 73 78 66 71 77 82
PRODUCT SPECIFICATIONS
EXPANDED COOLING DATA — VSH130601A*** (CONT.)
25
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS Outdoor Unit
Indoor Units Indoor Coil
Furnace/Blower
EER
TVA Ratings Total
Sens.
Heating Capacity High
HSPF
Low
ARI #
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314427
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314428
AR*F182416B*
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314429
ASPF183016B*
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314430
AT*F182416A*
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314431
CA*F1824*6C*
G*E80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314432
CA*F1824*6C*
G*V80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314433
CA*F1824*6C*
G*V950453B**
18,000
13,100
13.5
11.8
16,700
13,000
16,800
7.7
8,600 3314434
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314435
MBE1200**-1B*
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3315416
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314436
CHPF1824A6A*+EEP CHPF2430B6B*
G*E80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314437
CHPF2430B6B*
G*V80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314438
CHPF2430B6B*
G*V950453B**
18,000
13,100
13.5
11.8
16,700
13,000
16,800
7.7
8,600 3314439
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314440
14
12.2
16,700
13,000
16,800
8
8,600 3314441
CHPF2430B6B*+EEP CSCF1824N6A*
G*E80704B**
18,000
13,100
CSCF1824N6A*
G*V80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314442
CSCF1824N6A*
G*V950453B**
18,000
13,100
13.5
11.8
16,700
13,000
16,800
7.7
8,600 3314443
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314444
CSCF1824N6A*+EEP CSCF3036N6B*
G*E80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314445
CSCF3036N6B*
G*V80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314446
CSCF3036N6B*
G*V950453B**
18,000
13,100
13.5
11.8
16,700
13,000
16,800
7.7
8,600 3314447
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314448
14
12.2
16,700
13,000
16,800
8
8,600 3314449
CSCF3036N6B*+EEP CT*F1824*6A*
G*E80704B**
18,000
13,100
CT*F1824*6A*
G*V80704B**
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3314450
CT*F1824*6A*
G*V950453B**
18,000
13,100
13.5
11.8
16,700
13,000
16,800
7.7
8,600 3314451
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314452
CT*F1824*6A*+EEP CT*F1824*6A*
VSH13 0241A*
SEER
ADPF182416B*
CA*F1824*6C*
VSH13 0191A*
Sens.
AEPF183016C*
CA*F1824*6C*+EEP
VSH13 0181A*
Cooling Capacity (BTU/h) Total
18,000
13,100
14
12.2
16,700
13,000
16,800
8
8,600 3315426
ACNF24XX16A*
18,000
13,100
13
11.5
16,700
13,000
16,800
7.7
8,600 3314453
AR*F182416B*
18,400
13,400
13
11.5
17,000
13,300
17,000
8
8,800 3314454
ASPF183016B*
18,000
13,100
14
12.2
16,700
13,000
17,000
8
8,800 3314455
AT*F182416A*
18,400
13,400
13
11.5
17,000
13,300
17,000
8
8,800 3314456
AWUF18XX16A*
18,000
13,100
13
11.5
16,700
13,000
16,800
7.8
8,600 3315554
AWUF24XX16A*
18,000
13,100
13
11.5
16,700
13,000
16,800
7.8
8,600 3315555
ADPF182416B*
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314457
AEPF183016C*
23,000
17,000
14
12.2
21,300
16,800
22,000
8
12,000 3314458
AEPF303616C*
23,400
17,300
14
12.2
21,700
17,000
22,000
8
12,000 3314459
AR*F182416B*
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314460
ASPF183016B*
23,000
17,000
14
12.2
21,300
16,800
22,000
8.2
12,000 3314461
ASPF303616B*
23,400
17,300
14
12.2
21,700
17,000
22,000
8
12,000 3314462
AT*F182416A*
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314463
AWUF30XX16B*
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314464
AWUF36XX16B*
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314465
23,000
17,000
14
12.2
21,300
16,800
22,000
8
12,000 3315417
CA*F1824*6C*
MBE1200**-1B*
MBE1200**-1B*
See Notes on Page 32.
26
www.goodmanmfg.com
SS-VSH13
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit
Indoor Units Indoor Coil
Furnace/Blower
EER
Total
Sens.
High
HSPF
Low
ARI #
G*E80704B**
23,000
17,000
14
12.2
21,300
16,800
22,000
7.7
12,000 3314466
G*V80704B**
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314467
CA*F3030*6B*
G*V950453B**
23,000
17,000
13
11.8
21,300
16,800
22,000
7.7
12,000 3314468
CA*F3030*6B*+EEP
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314469
CHPF1824A6A*+EEP
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314470
CHPF2430B6B*
G*E80704B**
23,000
17,000
14
12.2
21,300
16,800
22,000
7.7
12,000 3314471
CHPF2430B6B*
G*V80704B**
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314472
CHPF2430B6B*
G*V950453B**
23,000
17,000
13.5
11.8
21,300
16,800
22,000
7.7
12,000 3314473
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314474
CSCF1824N6A*
G*E80704B**
23,000
17,000
14
12.2
21,300
16,800
22,000
7.7
12,000 3314475
CSCF1824N6A*
G*V80704B**
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314476
CSCF1824N6A*
G*V950453B**
23,000
17,000
13.5
11.8
21,300
16,800
22,000
7.7
12,000 3314477
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314478
CSCF3036N6B*
G*E80704B**
23,000
17,000
14
12.2
21,300
16,800
22,000
7.7
12,000 3314479
CSCF3036N6B*
G*V80704B**
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314480
CSCF3036N6B*
G*V950453B**
23,000
17,000
13.5
11.8
21,300
16,800
22,000
7.7
12,000 3314481
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314482
CT*F1824*6A*
MBE1200**-1B*
23,000
17,000
14
12.2
21,300
16,800
22,000
8
12,000 3315427
CT*F3030*6A*
G*E80704B**
23,000
17,000
14
12.2
21,300
16,800
22,000
7.7
12,000 3314483
CT*F3030*6A*
G*V80704B**
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314484
CT*F3030*6A*
G*V950453B**
23,000
17,000
13
11.8
21,300
16,800
22,000
7.7
12,000 3314485
CSCF3036N6B*+EEP
VSH13 0301A*
Heating Capacity
SEER
CA*F3030*6B*
CSCF1824N6A*+EEP
VSH13 0251A*
TVA Ratings
Sens.
CA*F3030*6B*
CHPF2430B6B*+EEP VSH13 0241A* (cont.)
Cooling Capacity (BTU/h) Total
CT*F3030*6A*+EEP
23,000
17,000
13
11.5
21,300
16,800
22,000
7.7
12,000 3314486
ACNF24XX16A*
23,600
17,400
13
11.5
21,800
17,200
22,600
7.7
12,400 3314487
AR*F182416B*
24,000
17,600
13
11.5
22,200
17,500
22,600
8
12,400 3314488
ASPF183016B*
23,000
17,000
14
12.2
21,300
16,800
22,000
8
12,000 3314489
ASPF303616B*
23,400
17,300
14
12.2
21,600
17,100
23,600
7.8
12,400 3314490
AT*F182416A*
24,000
17,600
13
11.5
22,200
17,500
22,600
8
12,400 3314491
AWUF24XX16A*
23,000
17,000
13
11.5
21,300
16,800
22,600
7.8
12,400 3315556
AWUF30XX16B*
23,600
17,400
13
11.5
21,800
17,200
22,600
7.8
12,400 3314492
AWUF36XX16B*
23,600
17,400
13
11.5
21,800
17,200
22,600
7.8
12,400 3314493
ADPF304216B*
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314494
AEPF183016C*
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314495
AEPF303616C*
29,000
21,800
14
12.2
26,800
21,400
26,800
8
14,000 3314496
AR*F182416B*+TXV
27,800
20,900
13
11.5
25,700
20,600
26,600
7.7
14,000 3314497
AR*F303016B*
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314498
ASPF183016B*
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314499
ASPF303616B*
28,400
21,300
14
12.2
25,900
20,700
26,800
8
14,000 3314500
AT*F303016A*
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314501
AWUF37XX16B*
28,400
21,300
13
11.5
25,900
20,700
25,000
7.8
15,000 3314502
CA*F3131*6C*
G*V80704B**
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314503
CA*F3131*6C*
G*V950704C**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.8
14,000 3314504
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314505
CA*F3131*6C*+EEP CA*F3131*6C*
MBE1200**-1B*
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.8
14,000 3315418
CA*F3636*6B*
G*E80704B**
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314506
See Notes on Page 32. SS-VSH13
www.goodmanmfg.com
27
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit
Indoor Units Indoor Coil
Furnace/Blower
CA*F3636*6B*+EEP
VSH13 0361A*
SEER
EER
TVA Ratings Total
Sens.
Heating Capacity High
HSPF
Low
ARI #
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314507
G*V80704B**
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314508
CHPF2430B6B*
G*V90704C**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.7
14,000 3314509
CHPF2430B6B*
G*V950704C**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.7
14,000 3314510
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314511
CSCF3036N6B*
G*V80704B**
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314512
CSCF3036N6B*
G*V90704C**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.7
14,000 3314513
CSCF3036N6B*
G*V950704C**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.7
14,000 3314514
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314515
CSCF3642N6C*
G*E80704B**
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314516
CT*F3131*6A*
G*V80704B**
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314517
CT*F3131*6A*
G*V950453B**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.7
14,000 3314518
CT*F3131*6A*
G*V950704C**
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.8
14,000 3314519
28,000
21,000
13
11.5
25,900
20,700
26,800
7.7
14,000 3314520
CT*F3131*6A*
MBE1200**-1B*
28,000
21,000
13.5
11.8
25,900
20,700
26,800
7.8
14,000 3315428
CT*F3131*6A*+TXV
MBE1200**-1B*
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3315429
CT*F3636*6A*
G*E80704B**
14,000 3314521
CSCF3036N6B*+EEP
CT*F3131*6A*+EEP
VSH13 0311A*
Sens.
CHPF2430B6B*
CHPF2430B6B*+EEP
VSH13 0301A* (cont.)
Cooling Capacity (BTU/h) Total
28,000
21,000
14
12.2
25,900
20,700
26,800
8
ACNF30XX16A*
27,000
21,100
13
11.5
25,000
20,800
25,600
7.7
14,000 3314522
AR*F303016B*
28,000
21,000
13
11.5
25,900
20,700
26,000
8
15,000 3314523
ASPF183016B*
28,000
21,000
14
12.2
25,900
20,700
26,800
8
14,000 3314524
ASPF303616B*
28,400
21,300
14
12.2
26,300
21,000
26,800
8
14,000 3314525
AT*F303016A*
28,000
21,000
13
11.5
25,900
20,700
26,000
8
15,000 3314526
AWUF30XX16B*
27,400
21,400
13
11.5
25,300
21,000
25,600
8
14,400 3314527
AWUF36XX16B*
27,400
21,400
13
11.5
25,300
21,000
25,600
8
14,400 3314528
AWUF37XX16B*
27,400
21,400
13
11.5
25,300
21,000
26,000
8
15,000 3314529
ADPF304216B*
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314530
AEPF303616C*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314531
AEPF426016C*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314532
AR*F363616B*
34,400
26,100
13
11.5
31,800
25,800
32,600
7.8
16,000 3314533
AR*F364216B*
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314534
AR*F374316B*
35,000
26,600
13
11.5
32,400
26,200
34,000
8
19,400 3314535
ASPF303616B*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314536
ASPF426016B*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314537
AT*F363616A*
34,400
26,100
13
11.5
31,800
25,800
32,600
7.8
16,000 3314538
AT*F364216A*
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314539
AWUF37XX16B*
33,400
25,400
13
11.5
30,900
25,000
31,000
7.8
17,000 3314540
CA*F3636*6B*
G*V90704C**
33,600
25,500
13.5
11.8
31,100
25,200
32,000
8
16,000 3314541
CA*F3642*6B*
G*E80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314542
CA*F3642*6B*
G*V80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314543
CA*F3642*6B*
G*V81155C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314544
CA*F3642*6B*
G*V90905D**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314545
CA*F3642*6B*
G*V950905D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314546
CA*F3642*6B*
G*V951155D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314547
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314548
CA*F3642*6B*+EEP See Notes on Page 32.
28
www.goodmanmfg.com
SS-VSH13
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit
Indoor Units Indoor Coil
Furnace/Blower
TVA Ratings
Heating Capacity
Sens.
SEER
EER
Total
Sens.
High
HSPF
Low
ARI #
CA*F3642*6B*
MBE1600**-1B*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3315419
CA*F3743*6A*
G*E80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314549
CA*F3743*6A*
G*V80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314550
CA*F3743*6A*
G*V81155C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314551
CA*F3743*6A*
G*V90905D**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314552
CA*F3743*6A*
G*V950704C**
34,000
25,800
13.5
11.8
31,500
25,500
32,000
8
16,000 3314553
CA*F3743*6A*
G*V950905D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314554
CA*F3743*6A*
G*V951155D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314555
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314556
CA*F3743*6A*
MBE1600**-1B*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3315421
CA*F3743*6A*+TXV
G*V90704C**
34,400
26,100
13.5
11.8
31,800
25,800
32,000
8
16,000 3314557
CA*F3743*6A*+TXV
G*V950704C**
34,000
25,800
13.7
12
31,500
25,500
32,000
8
16,000 3314558
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314559
CA*F3743*6A*+EEP
CHPF3636B6B*+EEP CHPF3642C6B*
G*E80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
7.8
16,000 3314560
CHPF3642C6B*
G*V80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
7.7
16,000 3314561
CHPF3642C6B*
G*V81155C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314562
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314563
CHPF3642D6B*
G*V90905D**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314564
CHPF3642D6B*
G*V950905D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314565
CHPF3642D6B*
G*V951155D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314566
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314567
CHPF3642C6B*+EEP
VSH13 0361A* (cont.)
Cooling Capacity (BTU/h) Total
CHPF3642D6B*+EEP CSCF3642N6C*
G*E80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314568
CSCF3642N6C*
G*V80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314569
CSCF3642N6C*
G*V81155C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314570
CSCF3642N6C*
G*V90905D**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314571
CSCF3642N6C*
G*V950905D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314572
CSCF3642N6C*
G*V951155D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314573
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314574
CSCF3642N6C*+EEP CT*F3636*6A*
G*V950704C**
33,600
25,500
13.5
11.8
31,100
25,200
32,000
8
16,000 3314575
CT*F3636*6A*+TXV
G*V950704C**
33,600
25,500
13.7
12
31,100
25,200
32,000
8
16,000 3314576
CT*F3642*6A*
G*E80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314577
CT*F3642*6A*
G*V80905C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314578
CT*F3642*6A*
G*V81155C**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314579
CT*F3642*6A*
G*V90905D**
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3314580
CT*F3642*6A*
G*V950704C**
34,000
25,800
13.5
11.8
31,500
25,500
32,000
8
16,000 3314581
CT*F3642*6A*
G*V950905D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314582
CT*F3642*6A*
G*V951155D**
35,000
26,600
13.5
11.8
32,400
26,200
32,000
7.7
16,000 3314583
35,000
26,600
13
11.5
32,400
26,200
32,000
7.7
16,000 3314584
CT*F3642*6A*+EEP CT*F3642*6A*
MBE1600**-1B*
35,000
26,600
14
12.2
32,400
26,200
32,000
8
16,000 3315430
CT*F3642*6A*+TXV
G*V90704C**
34,400
26,100
13.5
11.8
31,800
25,800
32,000
8
16,000 3314585
CT*F3642*6A*+TXV
G*V950704C**
34,000
25,800
13.7
12
31,500
25,500
32,000
8
16,000 3314586
See Notes on Page 32. SS-VSH13
www.goodmanmfg.com
29
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit
Indoor Units Indoor Coil
Heating Capacity
SEER
EER
Total
Sens.
High
HSPF
ADPF304216B*
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314587
AEPF426016C*
41,000
31,200
14
12.2
37,900
30,700
39,500
8.2
23,000 3314588
AR*F364216B*
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314589
ASPF426016B*
41,000
31,200
14
12.2
37,900
30,700
39,500
8.2
23,000 3314590
AT*F364216A*
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314591
CA*F3642*6B*+EEP
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314592
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3315420
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314593
MBE1600**-1B*
Low
ARI #
Sens.
CA*F3743*6A*+EEP CA*F3743*6A*
MBE1600**-1B*
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3315422
CA*F4860*6B*
G*E80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314594
CA*F4860*6B*
G*E81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314595
CA*F4860*6B*
G*V80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314596
CA*F4860*6B*
G*V81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314597
CA*F4860*6B*
G*V90905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314598
CA*F4860*6B*
G*V950905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314599
CA*F4860*6B*
G*V951155D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314600
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314601
CHPF3642C6B*+EEP CHPF3642D6B*+EEP
VSH13 0421A*
TVA Ratings
Total
CA*F3642*6B*
Furnace/Blower
Cooling Capacity (BTU/h)
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314602
CHPF4860D6C*
G*E80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314603
CHPF4860D6C*
G*E81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314604
CHPF4860D6C*
G*V80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314605
CHPF4860D6C*
G*V81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314606
CHPF4860D6C*
G*V90905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314607
CHPF4860D6C*
G*V950905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314608
CHPF4860D6C*
G*V951155D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314609
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314610
CSCF3642N6C*+EEP CSCF4860N6C*
G*E80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314611
CSCF4860N6C*
G*E81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314612
CSCF4860N6C*
G*V80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314613
CSCF4860N6C*
G*V81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314614
CSCF4860N6C*
G*V90905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314615
CSCF4860N6C*
G*V950905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314616
CSCF4860N6C*
G*V951155D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314617
40,000
30,400
13
11.5
37,000
30,000
39,000
8
23,000 3314618
CT*F3642*6A*
MBE1600**-1B*
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3315431
CT*F4860*6A*
G*E80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314619
CT*F4860*6A*
G*E81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314620
CT*F4860*6A*
G*V80905C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314621
CT*F4860*6A*
G*V81155C**
41,000
31,200
14
12.2
37,900
30,700
39,000
8.2
23,000 3314622
CT*F4860*6A*
G*V90905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314623
CT*F4860*6A*
G*V950905D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314624
CT*F4860*6A*
G*V951155D**
41,000
31,200
13.5
11.8
37,900
30,700
39,000
8
23,000 3314625
CT*F3642*6A*+EEP
See Notes on Page 32.
30
www.goodmanmfg.com
SS-VSH13
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit
Indoor Units Indoor Coil
Furnace/Blower
TVA Ratings
Heating Capacity Low
ARI #
Total
Sens.
SEER
EER
Total
Sens.
High
HSPF
ADPF486016B*
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314626
AEPF426016C*
45,000
34,200
14
12.2
41,600
33,700
43,000
8.4
27,000 3314627
AR*F486016B*
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314628
AR*F496116A*
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314629
ASPF426016B*
45,000
34,200
14
12.2
41,600
33,700
43,000
8.4
27,000 3314630
AT*F486016A*
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314631
CA*F4860*6B*
G*E80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314632
CA*F4860*6B*
G*E81155C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314633
CA*F4860*6B*
G*V80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314634
CA*F4860*6B*
G*V81155C**
45,000
34,200
14
12.2
41,600
33,700
43,000
8.4
27,000 3314635
CA*F4860*6B*
G*V90905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314636
CA*F4860*6B*
G*V950905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314637
CA*F4860*6B*
G*V951155D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314638
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314639
CA*F4860*6B*+EEP
VSH13 0481A*
Cooling Capacity (BTU/h)
CA*F4860*6B*
MBE2000**-1B*
45,000
34,200
14
12.2
41,600
33,700
43,000
8.4
27,000 3315423
CHPF4860D6C*
G*E80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314640
CHPF4860D6C*
G*E81155C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314641
CHPF4860D6C*
G*V80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314642
CHPF4860D6C*
G*V81155C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314643
CHPF4860D6C*
G*V90905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314644
CHPF4860D6C*
G*V950905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314645
CHPF4860D6C*
G*V951155D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314646
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314647
45,000
34,200
14
12.2
41,600
33,700
45,000
8.5
26,000 3315425
CHPF4860D6C*+EEP CHPF4860D6C*
MBE2000**-1B*
CHPF4860D6C*+TXV
MBE2000**-1B*
45,500
34,400
14.5
12
41,800
33,900
45,000
8.5
26,000 3314648
CSCF4860N6C*
G*E80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314649
CSCF4860N6C*
G*E81155C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314650
CSCF4860N6C*
G*V80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314651
CSCF4860N6C*
G*V81155C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314652
CSCF4860N6C*
G*V90905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314653
CSCF4860N6C*
G*V950905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314654
CSCF4860N6C*
G*V951155D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314655
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314656
CSCF4860N6C*+EEP CT*F4860*6A*
G*E80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314657
CT*F4860*6A*
G*E81155C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314658
CT*F4860*6A*
G*V80905C**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314659
CT*F4860*6A*
G*V81155C**
45,000
34,200
14
12.2
41,600
33,700
43,000
8.4
27,000 3314660
CT*F4860*6A*
G*V90905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314661
CT*F4860*6A*
G*V950905D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314662
CT*F4860*6A*
G*V951155D**
45,000
34,200
13.5
11.8
41,600
33,700
43,000
8.3
27,000 3314663
45,000
34,200
13
11.5
41,600
33,700
43,000
8.2
27,000 3314664
45,000
34,200
14
12.2
41,600
33,700
43,000
8.4
27,000 3315432
CT*F4860*6A*+EEP CT*F4860*6A*
MBE2000**-1B*
See Notes on Page 32. SS-VSH13
www.goodmanmfg.com
31
PRODUCT SPECIFICATIONS
ARI PERFORMANCE RATINGS (CONT.) Outdoor Unit
VSH13 0601A*
Indoor Units Indoor Coil
Furnace/Blower
Cooling Capacity (BTU/h) SEER
EER
TVA Ratings Total
Sens.
Heating Capacity High
HSPF
Low
ARI #
Total
Sens.
ADPF486016B*
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314665
AEPF426016C*
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.6
35,000 3314666
AR*F486016B*
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314667
AR*F496116A*
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314668
ASPF426016B*
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.6
35,000 3314669
ASPF426016B*+TXV
55,500
40,000
14
12.2
51,300
39,500
55,500
8.6
35,000 3314670
AT*F486016A*
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314671
CA*F4860*6B*
G*V80905C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314672
CA*F4860*6B*
G*V81155C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314673
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314674
CA*F4860*6B*+EEP CA*F4860*6B*
MBE2000**-1B*
55,500
40,000
13.5
11.8
51,300
39,500
55,500
8.6
35,000 3315424
CHPF4860D6C*
G*V80905C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314675
CHPF4860D6C*
G*V81155C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314676
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314677
CSCF4860N6C*
G*V80905C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314678
CSCF4860N6C*
G*V81155C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314679
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314680
CT*F4860*6A*
G*V80905C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314681
CT*F4860*6A*
G*V81155C**
55,500
40,000
13.3
11.7
51,300
39,500
55,500
8.5
35,000 3314682
55,500
40,000
13
11.5
51,300
39,500
55,500
8.5
35,000 3314683
MBE2000**-1B*
55,500
40,000
13.5
11.8
51,300
39,500
55,500
8.6
35,000 3315433
CHPF4860D6C*+EEP
CSCF4860N6C*+EEP
CT*F4860*6A*+EEP CT*F4860*6A*
¹ Seasonal Energy Efficiency Ratio; Certified per ARI 210/240 @ 80°F/ 67°F/ 95°F ² Energy Efficiency Ratio @ 80 °F/67 °F Inside - 95 °F Notes: • Always check the S&R plate for electrical data on the unit being installed. • When matching the outdoor unit to the indoor unit, use the piston supplied with the outdoor unit or that specified on the piston kit chart supplied with the indoor unit. • EEP: Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling time delay.
32
www.goodmanmfg.com
SS-VSH13
PRODUCT SPECIFICATIONS
DIMENSIONS W D
H
Dimensions Model
SS-VSH13
W"
D"
H"
VSH130181A*
26
26
32¼
VSH130191A*
29
29
34¼
VSH130241A*
26
26
32¼
VSH130251A*
29
29
34¾
VSH130301A*
26
26
34¼
VSH130311A*
29
29
34¾
VSH130361A*
29
29
38¼
VSH130421A*
29
29
32¼
VSH130481A*
29
29
34¾
VSH130601A*
35½
35½
34¾
www.goodmanmfg.com
33
34
L2
L1
1
SR
www.goodmanmfg.com
IO
CM
AUX
MAIN
BK
O O
OR
BR
BK
PU
BL
YL
ALTERNATE DOUBLE POLE CONTACTOR
T2
T1
YL
2
5
BK
BL
C Y
BK
H V D R
BK
S
DF1
DF2
BK
YL
RD RD
BK
BK
WARNING
CH (IF USED) NOTE 3
R
AUX
MAIN
COMP
RD
DFT
C
BK
RD
R R
RD
YL
RD
WH
W2
LVDR
DC
BK
YL
YL
BK
L1
T1
BK
L2
T2
RCCF
YL
YL
BL
HERM YL F
SA (IF USED) NOTE 2 RD
BR
C
RD
RD
RD
YL
EQUIPMENT GROUND USE COPPER CONDUCTORS ONLY
RD
PU
C
RD
RD
Y
YL L1 C
R
R
T1
IO
LVDR
DFT
SR
O
W2
DFT
2
M AI N
X AU
Y
DC
C
(IF USED) NOTE 3
CH
CM
IO
X S AU COMP M AI N R
DF2
HVDR
DF1
C
5
F
SC
C
(IF USED)
SA
RCCF
RVC
H
1
OUTDOOR POWER SUPPLY SEE RATING PLATE
T2 C
VENDOR: GOODMAN PRINT SHOP
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION. 07/05
L2
0140R00019P
USE N.E.C. CLASS 2 WIRE
COMPONENT CODE C LPS O C --------------- CONTACTOR CH ------------- CRANKCASE HEATER CM ------------ OUTDOOR FAN MOTOR R C COMP -------- COMPRESSOR W2 O Y DC ------------- DEFROST CONTROL DFT ----------- DEFROST THERMOSTAT INDOOR POWER HVDR -------- HIGH VOLTAGE DEFROST RELAY SUPPLY IO -------------- INTERNAL OVERLOAD LPS ------------ LOW PRESSURE SWITCH LVDR --------- LOW VOLTAGE DEFROST RELAY NOTES: 1) TO INDOOR UNIT LOW VOLTAGE LVJB ---------- LOW VOLTAGE JUNCTION BOX TERMINAL BLOCK & INDOOR RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN THERMOSTAT. 2) START ASSIST FACTORY RVC ----------- REVERSING VALVE COIL EQUIPPED WHEN REQUIRED. 3) CRANKCASE HEATER MAY BE SA ------------- START ASSIST FACTORY OR FIELD INSTALLED. SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL) SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE
WIRING CODE FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE OPTIONAL HIGH VOLTAGE
COLOR CODE BK --------------- BLACK BL --------------- BLUE BR --------------- BROWN OR --------------- ORANGE PU --------------- PURPLE RD --------------- RED WH -------------- WHITE YL --------------- YELLOW
NOTE 1
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
LPS
DFT
RVC
YL
BL
BK BK BL BK BK
SC
O
OR C
W2
WH
BL
R
RD
LVJB
ALTERNATE DOUBLE POLE CONTACTOR ONLY
CONTROL BOX
PRODUCT SPECIFICATIONS
WIRING DIAGRAM
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring schematic.
SS-VSH13
PRODUCT SPECIFICATIONS
ACCESSORIES Model
VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 VSH13 018 019 024 025 030 031 036 042 048 060
ABK-20
Anchor Bracket Kit ▼
X
X
X
X
X
X
X
X
X
X
AFE18-60A
All-fuel Kit
X
X
X
X
X
X
X
X
X
X
ASC01
Anti-Short Cycle Kit
X
X
X
X
X
X
X
X
X
X
TBA
Hard-start Kit
X
X
X
X
X
X
X
TBA
Hard-start Kit
X
X
X
TBA
Hard-start Kit
X
X
FSK01A¹
Freeze Protection Kit
X
X
X
X
X
X
X
X
X
X
OT/EHR18-60
Emergency Heat Relay kit
X
X
X
X
X
X
X
X
X
X
OT18-60A²
Outdoor Thermostat with Lockout Stat
X
X
X
X
X
X
X
X
X
X
TX3N2³
TXV Kit -- Field-installed, nonbleed, expansion valve kit
X
X
X
X
X
X
X
TX5N2³
TXV Kit -- Field-installed, nonbleed, expansion valve kit
X
X
X
▼
¹ ² ³
Description
X
Contains 20 brackets; four brackets needed to anchor unit to pad Installed on indoor coil Required for heat pump applications where ambient temperatures fall below 0 °F with 50% or higher relative humidity. Condensing units and heat pumps with reciprocating compressors require the use of start-assist components when used in conjunction with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device.
SS-VSH13
www.goodmanmfg.com
35
PRODUCT SPECIFICATIONS
NOTES
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. Copyright © 2009 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
36
www.goodmanmfg.com
SS-VSH13