13 Seer R22 60hz Cond Unit Technical

   EMBED


Share

Transcript

McQuay 13 SEER R-22 60Hz Cond. Unit Size Model Function Rated Voltage Rated Frequency Total Capacity (W/Btu/h) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (CFM's) SEER Compressor Manufacturer/trademark Compressor Type 18K 24K 30K MCU-132018-CCU216A MCU-132024-CCU216A MCU-132030-CCU216A COOLING ONLY COOLING ONLY COOLING ONLY 208V -230V~1PH 208V -230V~1PH 208V -230V~1PH 60Hz 5275/18000 60Hz 7033/24000 60Hz 8792/30000 1335 1970 2500 1496 2407 3130 6.3 8.7 11.9 780 795 970 13 13 13 Panasonic Panasonic Panasonic Rotary compressor Rotary compressor Rotary compressor L.R.A. (A) 38 49 68 Compressor RLA(A) 6.2 8.4 11 Compressor Power Input(W) Overload Protector ℃ Working Temp Range ( ) 1147 Inherent 19.4 - 46.1 Aluminum fin-copper tube Aluminum fin-copper tube 9.52 7 7 Rows-Fin Gap(mm) 2-1.8 2-1.5 2-1.5 1741.2×558.8×44 1762×571.5×25.4 2169×685.8×25.4 Fan Motor Speed (rpm) 800 800 820 Output of Fan Motor (W) 120 120 150 Fan Motor Capacitor (uF) 6 6 6 Axial fan –1 Axial fan –1 Axial fan –1 Fan Type-Piece Fan Diameter (mm) 456 456 560 Max Operating Pressure for the Discharge Side(MPa) 2.5 2.5 2.5 Max Operating Pressure for the Suction Side(MPa) 0.6 0.6 0.6 Sound Pressure Level dB (A) 59 62 62 Dimension (W/H/D) ( mm) 610X610X604 610X610X604 710X 710X 718 Dimension of Package (L/W/H)( mm) 648X648X634 648X648X634 770X770X740 Net Weight /Gross Weight (kg) Refrigerant / Charge (kg) Precharge for Standard Piping Length (m) Gas additional charge(g/m) Outer Diameter Max Distance 54/56 55/57 75/77 R22 / 2.5 6 R22 / 3 6 R22 / 4.5 6 40 40 50 Liquid Pipe (inch) 3/8 3/8 3/8 Gas Pipe (inch) 5/8 5/8 3/4 Height (m) 15 15 15 Length (m) 30 30 30 Brazing Connection Brazing Connection Brazing Connection 216 135 36K 48K 60K MCU-132036-CCU216A MCU-132048-CCU216A MCU-132060-CCU216A COOLING ONLY COOLING ONLY COOLING ONLY 208V -230V~1PH 208V -230V~1PH 208V -230V~1PH 60Hz 10550/36000 60Hz 14068/48000 60Hz 17585/60000 2900 4050 5121 3650 5550 5770 14.5 18.5 21.8 1177 1650 1765 connection method Loading Quantity 40’ High Cube Container Size Model Function Rated Voltage Rated Frequency Total Capacity (W/Btu/h) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (CFM's) SEER Compressor Manufacturer/trademark Compressor Type L.R.A. (A) 13 13 13 Copeland Copeland Copeland Scroll compressor Scroll compressor Scroll compressor 84 109 Compressor RLA(A) 16.4 20.4 28 Compressor Power Input(W) 2240 3790 4830 Overload Protector ℃ Working Temp Range ( ) Internal Internal Internal 19.4~46.1 19.4~46.1 Aluminum fin-copper tube Aluminum fin-copper tube Pipe Diameter (mm) 7 7 7 Rows-Fin Gap(mm) 2-1.5 2-1.5 2-1.5 Coil length (l) x height (H) x width (L) Unit 2169×685.8×25.4 2169×800.1×25.4 2213×800.1×25.4 Fan Motor Speed (rpm) 820 890 890 Output of Fan Motor (W) 150 210 300 Fan Motor Capacitor (uF) 6 8 8 Fan Type-Piece Axial fan –1 Axial fan –1 Axial fan –1 Fan Diameter (mm) 560 560 610 Max Operating Pressure for the Discharge Side(MPa) 2.5 2.5 2.5 Max Operating Pressure for the Suction Side(MPa) 0.6 0.6 0.6 Sound Pressure Level dB (A) 63 64 68 Dimension (W/H/D) ( mm) 710X 710X 718 710X 710X 832 750X 750X 832 Dimension of Package (L/W/H)( mm) 770X770X750 770X770X852 770X770X852 83/85 85/87 100/105 R22 / 4.4 R22 / 5 R22 / 5.5 Net Weight /Gross Weight (kg) Refrigerant / Charge (kg) Precharge for Standard Piping Length (m) 6 6 6 Gas additional charge(g/m) 50 60 60 Liquid Pipe (inch) 3/8 1/2 1/2 Gas Pipe (inch) 3/4 9/8 9/8 Height (m) 15 15 15 Length (m) 30 30 30 connection method Brazing Connection Brazing Connection Brazing Connection 40’ High Cube Container 135 135 135 Outer Diameter Max Distance Loading Quantity 148 19.4~46.1 Condenser Aluminum fin-copper tube Pipe Connection 2312 Inherent 19.4 - 46.1 Pipe Diameter (mm) Coil length (l) x height (H) x width (L) Pipe Connection 1900 Inherent 19.4 - 46.1 Condenser Aluminum fin-copper tube Unit MCU2 Series McQuay International 2010