Transcript
Technical data LA 9TU High-efficiency air-to-water heat pump Device information
LA 9TU
Design - Heat source - Model - Regulation - Thermal energy metering - Installation location - Performance levels Operating limits - Min. return temperature / Max. flow temperature 7) - Lower operating limit heat source (heating operation) / Upper operating limit heat source (heating operation) Flow / sound - Max. heating water flow rate / Pressure drop - Minimum heating water flow rate / Pressure drop - Heat source flow (min.) - Sound power level device - Sound pressure level in 10 m 2) Dimensions/weight and filling quantities - Dimensions (W x H x D) 3) - Weight - Thread type, heating connection / Connection heating - Refrigerant / Amount of refrigerant - Oil type / Oil quantity Electrical connection - Connection voltage / Fuse protection - Control voltage / Control voltage fuse protection - Degree of protection - Initial current limiter - Starting current with soft starter - Nominal power consumption according to EN 14511 at A2/W35 / Maximum electric power consumption 1) - Nominal current at A2/W35 / Nominal current cos phi Complies with the European safety regulations Additional model features - Type of defrosting - Water in device protected against freezing 4) Warmwasserspeicher Heat output / coefficient of performance (COP) according to EN 14511: 1) Heating compressor 1 W35 A-7 5,2 kW / 2,8 A2 7,5 kW / 3,7 A7 9,2 kW / 4,2 A10 10,2 kW / 4,5
Outside air Universal design WPM EconPlus, wall-mounted Integrated Outdoors 1 18 / 58 °C +/- 2 -20 / 35 °C 1,6 m³/h / 7300 Pa 0,6 m³/h / 1100 Pa 2500 m³/h 60 dB (A) 30 dB (A) 910 x 1460 x 750 mm 208 kg G / 1 ¼ inch R404A / 3,4 kg Polyolester (POE) / 1,3 l 3/N/PE ~400 V, 50 Hz / C 16 A 1/N/PE ~230 V, 50 Hz / C 16 A IP 24 Yes 17 A 2 / 3,5 kW 4,9 A / 0,8
Reverse circulation Yes
W45 4,56 kW / 6,53 kW / 8,21 kW / 8,88 kW /
2,28 2,88 3,38 3,52
W55 3,98 kW / 5,88 kW / 7,1 kW / 7,81 kW /
1,87 2,41 2,7 2,92
Note: 1)
2) 3) 4) 7)
These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and regulation should be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on maintenance, commissioning and operation can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. A7 / W35: Heat source temperature 7 °C and heating water flow temperature 35 °C. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location. Please note that additional space is required for pipe connections, operation and maintenance. The heat circulating pump and the heat pump controller must always be ready for operation. Depending on the type of heat pump and refrigerant, the maximum flow temperatures in heating mode may decline with lower external temperatures. Further information can be found in the heat pump's operating limits diagram.
Glen Dimplex Deutschland GmbH Dimplex division Am Goldenen Feld 18 95326 Kulmbach
Page 1/3 Errors and omissions excepted! E-Mail:
[email protected] Internet: www.dimplex.de
Print date: 07.06.2012 Telephone: +49 (0)9221 709-562 Fax: +49 (0)9221 709-565
Heating characteristic LA 9TU High-efficiency air-to-water heat pump
Heat output in [kW]
Water outlet temperature in [°C]
18 35/30
16
45/38
14
55/45
12 10 8 6 4 2 0 -20
-10
0
10
20
30
40
Heat source inlet temperature [°C]
Power consumption (incl. proportion of pump output)
Pressure drop in [Pa]
4
10000
55
3
9000
45 35
2
Liquefier
8000
1
7000
0
6000
-20
-10
0
10
20
30
40
Heat source inlet temperature [°C] Coefficient of performance (incl. proportion of pump output)
7 6 5 4
35 45
5000 4000 3000
55 2000
3 2 1 0
1000 0
-20
-10
0
10
20
30
40
0
Heat source inlet temperature [°C]
Glen Dimplex Deutschland GmbH Dimplex division Am Goldenen Feld 18 95326 Kulmbach
Page 2/3 Errors and omissions excepted! E-Mail:
[email protected] Internet: www.dimplex.de
0,5
1
1,5
2
Heating water flow rate in [m³/h]
Print date: 07.06.2012 Telephone: +49 (0)9221 709-562 Fax: +49 (0)9221 709-565
Operating limits diagram LA 9TU High-efficiency air-to-water heat pump
Heating water temperature [°C] 75 70 65 60 55 50 45 40 35 30 25 20 15
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
Heat source inlet temperature [°C]
Note: The maximum possible flow temperature and the operating limits vary by +- 2K due to component tolerances. The minimum volume flow specified in the device information must be ensured at the lower operating limit. In mono energy operating mode with the heating element activated, the maximum flow temperature increases by approximately 3K.
Glen Dimplex Deutschland GmbH Dimplex division Am Goldenen Feld 18 95326 Kulmbach
Page 3/3 Errors and omissions excepted! E-Mail:
[email protected] Internet: www.dimplex.de
Print date: 07.06.2012 Telephone: +49 (0)9221 709-562 Fax: +49 (0)9221 709-565