Preview only show first 10 pages with watermark. For full document please download

134541 Zenith Chilltap Domestic Specs Sheet B 76121nz Ct1001

   EMBED


Share

Transcript

Zenith Specification Sheet Zenith Chilltap For The Home ® Instant Chilled Filtered Drinking Water Under Sink Domestic Chiller Zenith Chilltap Features • Instant chilled filtered drinking water at your fingertips • Delivers up to 60 glasses per hour • Cost effective solution to buying and storing bottled water • Delivers refreshingly chilled water between 5°C and 10°C • Triple-action sub-micron fully encapsulated filter • Chiller and filter system stored out-of-sight under the bench top Recovery rates Product Details Chilltap 60 glasses/hour Initial draw off glasses Recovery glasses/hr 8 60 Lic No. WMKA21821 ATS5200.105 SAI-Global As Zenith’s policy is one of continuous product improvement changes to specifications may be made without prior notice. 110371 Zenith Chilltap Domestic Specs Sheet B.indd 1 Specification Sheet ZENSSCTD1 | Updated February 2012 6/03/12 8:51 AM Zenith Specification Sheet Zenith Chilltap® For The Home Product Selection Chart Zenith Model Order Code Model No. With Sub Micron Filter Initial Draw Off Glasses* Recovery Glasses Per Hour Compressor (hp) W D H 76121NZ 8 60 .08 353 253 377 Chillltap For The Home Dimensions *Standard glass = 200mL Technical Features • Instant chilled filtered water at your fingertips. • Under-sink filtered water chiller with sink mounted quarter turn ceramic tap. • Up to 60 glasses of chilled water per hour. • Chrome plate brass tap head with quarter turn action lever and 360° swivel spout. • Chilled water temperature is maintained between 5-10°C. • Sub-micron filtration to NSF/ANSI 42 and/or 53 industry standard. • Tropic rated chilling system that is cost effective alternative to bottled water. • Pressure limiting valve equipped to protect filter against extreme water pressure. • Vented system to ensure system is never compromised due to surges in water pressure. • Air cooled condenser with a compressor rated at up to 0.25 hp. Installation Requirements Electrical Location To be connected to a 10amp GPO, 220V-240V AC power supply and in accordance with AS/NZS 3350 wiring regulations. Tap should be installed at the rear of a sink, on a flat surface to dispense into the sink. A 25mm diameter cut-out is required for fitting and under-sink chiller should be located if possible directly under the tap-maximum 1 metre away. Operational unit minimal clearances of 60mm left, right, rear and above. Filter should be mounted where readily accessible on the chiller unit or on the adjacent cupboard wall. Cupboard doors should be offset using 4mm buffers provided. When installing the unit where minimum clearances are met, consideration should be given to installing an auxiliary exhaust fan accessory. Suggested exhaust fan location is in side wall to adjoining cupboard or the floor of the cupboard into the kickboard space. Caution In some hard water areas where mineral scale accumulation may be a problem, consideration should be given to the maintenance required. A suitable form of water treatment may be necessary. Accessories 90650NZ – Aluminium ventilation grill kit 99015NZ – Disposable cup system 58000NZ – Sub-micron replacement filter Warranty 1 year parts and labour warranty. Plumbing Technical Assistance To be installed by a qualified tradesperson in accordance with manufacturer’s instructions and AS/NZS 3500 plumbing regulations. Water connections 15mm BSP. Designed for direct connection to a potable cold water supply with minimum pressure of 70kPa; maximum 700kPa. If static pressure exceeds 700kPa, a 500kPa pressure limiting valve must be fitted. An isolating valve should be installed between the water supply and the operational unit. Contact Zenith Heaters Ltd Unit 2/15 Moselle Avenue, Henderson Auckland 0610 New Zealand T: 0800 558 055 F: 0800 559 055 www.zenithheaters.co.nz 270 mm 129 mm Tap spout swivels 360º so it is out of the way when not in use. 65 mm Water supply Tropic-rated, air-cooled, super-quiet chiller is located beneath the tap. Initial draw-off rating is eight 200 ml glasses of chilled water at one time. Includes combination pressure-limiting valve and double non-return valve. 210 mm 305 mm Recovery rate is sixty 200 ml glasses of chilled water per hour. Pressure-limiting function limits filter cartridge water pressure to 600 kPa. 377 mm H Double non-return function prevents backflow from filter into water supply. Brass m/m connecter included – for connection to incoming water supply. Patented filter head makes changing filters as easy as changing a light globe. Filter cartridge simply slips up into the head -- a twist makes it water-tight. 353 mm W 253 mm D Note: under-sink unit can sit width or depth facing front As Zenith’s policy is one of continuous product improvement changes to specifications may be made without prior notice. 110371 Zenith Chilltap Domestic Specs Sheet B.indd 2 Specification Sheet ZENSSCTD1 | Updated February 2012 6/03/12 8:52 AM