Preview only show first 10 pages with watermark. For full document please download

1365414670 Meanwell Led

   EMBED


Share

Transcript

LED Power Supply 2013 April About MEAN WELL E stablished in 1982, ME AN WELL is a leading standard switching power supply manufacturer with advanced manufacturing facilities in Taiwan, GuangZhou, and SuZhou as well as sales of f ices in China, USA , and Europe. We have more than 5,000 standard models selling through 200 authorized distributors all over the world. Since 2006, we star ted to endeavor the development of waterproof LED power supplies. Thus far, more than 1000 models comply with specif ic lighting norms per UL8750, UL1310, UL879, EN61347-2-13, IEC61347-2-13(CB), and EN61000-3-2 Class C (harmonic current) have been launched in the market with utmost success. In this catalog, we are glad to introduce you dif ferent t ypes of LED power supplies, which are ver y suitable for LED street lighting, LED tunnel lighting, outdoor electronic display, of f ice lighting, LED decorative lighting, LED architectural lighting …etc. all kinds of outdoor or indoor LED lighting related applications. If they still can’t meet your requirement, ME AN WELL also of fers over 4,000 standard industrial switching power supplies from 5W to 3,000W for your selection. Please visit our website for more details — w w w.meanwell.com Featured New Products LCM-40(DA)/60(DA) Series Page 13 40W/ 60W multiple-stage output current supporting DALI interface HLG-C Series HVG(C)-150 Series Page 22 150W wide input range (180~528VAC) with PFC function Page 21 70W/ 90W/ 150W/ 200W Constant current output with high output voltage >60VDC HBG Series 100W/ 160W/ 240W Circular Shape for High Bay Lighting Page 25 Index 2 AP series 12~35W 16 LP series 18~100W 17 • Economical with Slim Plastic Case • IP67 5 ELN series PCD series 18~20 30~60W 7 PLD series PLM series 40~320W • IP65 & IP67 • 5 Years Warranty 21 HLG-C series 70~200W • C.C. Output with High Output Voltage>60VDC • PFC Function • Metal Case 16~60W 12~40W HLG series • Metal Case • 3 in 1 Dimming Function • 3 in 1 Dimming Function • PFC Function • Plastic Case 8 60~150W • High Efficiency with PFC Function 16~60W • PFC Function • Plastic Case • AC Phase-cut Dimming CLG series • PFC Function • Metal Case • IP65 & IP67 • Dimming Option • Plastic Case 6 60~96W • PFC Function • Metal Case • IP66 • Low Cost with Rectangular Plastic Case 3~4 CEN series • IP65 & IP67 • 5 years warranty 22 HVG(C) series 96~150W • PFC Function • Metal Case • IP65 & 67 • PFC Function • Economical with Plastic Case • Push Terminal I/O • Wide Input Range: 180~480VAC/100W ; 180~528VAC/150W • 5 years warranty 9 LPF series 16~90W • PFC Function • Plastic Case 10 23 • 3 in 1 Dimming Function • IP67 • PFC Function PLC series ULP series 30~96W SPD series 20~96W • 20kA Surge Protection Device • Plastic Case • PFC Function • Plastic Case • IP64 12 HLN series 40~80W 24 • 3 in 1 Dimming Function LCM series 40~60W 25 • DALI Interface and Push DIM • IP65 & IP67 26 Waterproof Output Connector 20~60W 27 How to Choose A Suitable LED Power Supply? 40~80W 28 Quick Selection Map 29 Comparison Chart • PFC Function • PCB Type HLP series 96~240W • 5 years warranty • Multiple-Stage C.C. Level Selectable by DIP S.W. 15 HBG series • 3 in 1 Dimming Function • Plastic Case with Push Terminal I/O PLP series Single Channel DC/DC Driver • PFC Function • Circular Shape Metal Case • PFC Function 14 LDD series • Plastic Case • Constant Current Output • Pin Style / Wire Style / SMD Style • PFC Function • Plastic Case • IP64 13 150W • U-bracket Type • PFC Function • Built-in lighting fixture • Screw Terminal I/O PLN series 70W • Rectangular Metal Case • IP65 • PFC Function • Plastic Case 11 HSG series • PFC Function • PCB Type • 3 in 1 Dimming Function 1 12~35W Single Output LED Power Supply Features •2Universal AC input / Full range •2Fully isolated plastic case •2Protections: Short circuit / Overload (APV only) / Over voltage •2Constant voltage design (C.V. mode) for APV series •2Constant current design (C.C. mode) for APC series • IP30 design • Withstand 300VAC surge input for 5 seconds (APV/C-25/35) APV-12/16 • Class 2 power unit / Pass LPS • Isolation class II, no F.G. •2Cooling by free air convection •2100% full load burn-in test •2Low cost, high reliability • Suitable for LED lighting and moving sign applications •22 years warranty APC-12/16 APV-25/35 APC-25/35 NE W INPUT O UT P U T AC input voltage range 90~264VAC ; 127~370VDC AC inrush current (max.) APC/V-12: Cold start, 70A at 230VAC APC-16: Cold start, 45A at 230VAC APV-16: Cold start, 50A at 230VAC Overload protection (APV only) Range >105% rated output current Type Hiccup up mode, auto-recovery Over voltage protection 110%~145% rated output voltage Withstand voltage I/P-O/P: 3.75kVAC Working temperature -30~+70OC (refer to output derating curve) Vibration 10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes Safety standards UL8750 approved; Design refer to TUV EN60950-1 Design refer to TUV EN60950-1, UL8750 EMC standards EN55015, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 UL rated, 18AWGx2C (15cm) UL rated, 18AWGx2C (15cm) Output UL rated, 20AWGx2C (15cm) UL rated, 18AWGx2C (15cm) Input Connection Dimension (LxWxH)(mm) APV-12 Series Model No. 77x 40x 29 84x 57x 29.5 APC-12 Series (C.V. mode) Output (C.C. mode) Tol. R&N Effi. Model No. Output Io Tol. R&N Effi. APV-12-5 APV-12-12 APV-12-15 5V, 0~2.0A 12V, 0~1.0A 15V, 0~0.8A ±5% ±5% ±5% 100mV 120mV 120mV 76% 82% 82% APC-12-350 9~36V, 350mA ±8% 300mV 82% APC-12-700 9~18V, 700mA ±8% 250mV 80% APV-12-24 24V, 0~0.5A ±5% 150mV 84% APV-16 Series Model No. (C.V. mode) Output Tol. R&N Effi. APV-16-5 APV-16-12 APV-16-15 5V, 0~2.60A 12V, 0~1.25A 15V, 0~1.00A ±5% ±5% ±5% 100mV 120mV 120mV 76% 80% 81% APV-16-24 24V, 0~0.67A ±5% 150mV 83% APV-25 Series (C.V. mode) APC-16 Series Model No. (C.C. mode) Output (for 700mA) (for 350mA) Io Tol. R&N Effi. APC-16-350 12~48V, 350mA ±8% 300mV 84% APC-16-700 9~24V, 700mA ±8% 250mV 83% APC-25 Series Model No. (C.C. mode) Output Io Tol. R&N Effi. ±8% 300mV 83% Model No. Output Tol. R&N Effi. APC-25-350 25~70V, 350mA APV-25-5 APV-25-12 APV-25-15 APV-25-24 5V, 0~3.5A 12V, 0~2.1A 15V, 0~1.68A 24V, 0~1.05A ±5% ±5% ±5% ±5% 120mV 150mV 150mV 150mV 75.5% 82.0% 83.0% 83.0% APC-25-500 15~50V, 500mA ±8% 300mV 83% APC-25-700 11~36V, 700mA ±8% 300mV 83% ±8% 300mV 83% APV-25-36 36V, 0~0.7A ±5% 150mV 84.0% APV-35 Series Model No. APV-35-5 APV-35-12 APV-35-15 APV-35-24 2 Cold start, 45A at 230VAC APV-35-36 Output 36V, 0~1.0A 9~24V, 1050mA APC-35 Series (C.V. mode) 5V, 0~5.0A 12V, 0~3.0A 15V, 0~2.4A 24V, 0~1.5A APC-25-1050 Tol. R&N Effi. Model No. ±5% ±5% ±5% ±5% 120mV 150mV 150mV 180mV 76.5% 83.0% 84.0% 84.0% APC-35-350 ±5% 180mV 85.0% (C.C. mode) Io Tol. R&N Effi. 28~100V, 350mA ±8% 350mV 84% Output APC-35-500 25~70V, 500mA ±8% 350mV 84% APC-35-700 15~50V, 700mA ±8% 350mV 84% APC-35-1050 11~33V, 1050mA ±8% 350mV 84% 18~100W Single Output LED Power Supply Features • • • • • • Isolation class II, no F.G. W ithstand 300VAC surge input for 5 seconds (except for LPH/LPL-18) Cooling by free air convection 100% full load burn-in test Low cost, high reliability Suitable for LED-based decorative/architectural lighting, LED stage and theater lighting, and LED electronic displays • 2 years warranty • L PV: Universal AC input / Full range LPH-18: 180~264VAC input only LPL - 18: 90~132VAC input only • Fully encapsulated with IP67 level • Protections: Short circuit / Overload / Over voltage /  Over temperature (LPH-18/LPL-18 only) • Constant voltage design (C.V. mode) • Class 2 power unit / Pass LPS (except for LPV-100) LPL-18 LPH-18 LPV-20 LPV-35 LPV-100 LPV-60 INPUT OUTPUT AC input voltage range 90~132VAC 180~264VAC 90~264VAC AC inrush current (max.) Cold start, 40A at 115VAC Cold start, 50A at 230VAC Cold start, 70A at 230VAC Overload Protection Range >105% Type Hiccup mode, auto-recovery Cold start, Cold start, 55A at 230VAC 60A at 230VAC Cold start, 75A at 230VAC -30~+65 OC -25~+70 OC 110%~150% Over voltage protection 115%~135% rated output voltage Withstand voltage I/P-O/P: 3kVAC Working temperature -30~+70 OC Vibration 10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes Safety standards TUV EN60950-1, EN61347-1, EN61347-2-13 approved for LPH-18 EMC standards FCC part 15 class B TUV EN60950-1(LPV-20 only), IEC61347-1, IEC61347-2-13 (LPV-35 only), UL1310 (except for LPV-60-5 & LPV-100), UL879 (except for LPV-35/100 & LPV-60-5) approved EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 Input Connection Output UL rated, 18AWGx2C (60cm) UL rated, 18AWGx2C (60cm) 18AWGx2C (30cm) UL rated,18AWGx2C (30cm) UL rated, 16AWGx2C (60cm) UL rated, 14AWGx2C (30cm) 140x 30x 22 118x 35x 26 148x 40x 30 162.5x 42.5x 32 190x 52x 37 Dimension (LxWxH)(mm) LPL-18 Series (C.V. mode) Model No. (LVD) Output Tol. R&N Effi. LPL-18-12 12V, 0~1.5A ±3% 120mV 80% LPL-18-24 24V, 0~0.75A ±3% 150mV 83% LPL-18-36 36V, 0~0.5A ±3% 200mV 84% LPH-18 Series Model No. LPV-35 Series Model No. LPV-35-5 LPV-35-12 LPV-35-15 LPV-35-24 LPV-35-36 Model No. LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 LPV-60-48 Tol. R&N Effi. LPH-18-12 12V, 0~1.5A ±3% 120mV 78% LPH-18-24 24V, 0~0.75A ±3% 150mV 82% LPH-18-36 36V, 0~0.5A ±3% 200mV 83% Output Tol. R&N Effi. Model No. 5V, 0~3.0A ±5% 80mV 77% LPV-20-12 12V, 0~1.67A ±5% 120mV 81% LPV-20-15 15V, 0~1.33A ±5% 120mV 83% LPV-20-24 24V, 0~0.84A ±5% 150mV 83% LPV-100-5 LPV-100-12 LPV-100-15 LPV-100-24 LPV-100-36 LPV-100-48 Model No. LPV-20-5 (C.V. mode) Output 5V, 0~5.0A (peak 6A) 12V, 0~3.0A 15V, 0~2.4A 24V, 0~1.5A 36V, 0~1.0A LPV-60 Series (C.V. mode) Output LPV-20 Series -30~+70 OC (C.V. mode) Output 5V, 0~8.0A 12V, 0~5.0A 15V, 0~4.0A 24V, 0~2.5A 36V, 0~1.67A 48V, 0~1.25A LPV-100 Series (C.V. mode) Tol. ±6% ±5% ±5% ±5% ±5% R&N 80mV 120mV 120mV 150mV 150mV (for 48V only) Tol. ±8% ±5% ±5% ±5% ±5% ±5% Effi. 77% 84% 84% 85% 85% (for 12~36V) R&N 80mV 120mV 120mV 150mV 150mV 150mV Effi. 76% 83% 83% 86% 86% 86% Tol. R&N Effi. ±8% ±5% ±5% ±5% ±5% ±5% 80mV 120mV 120mV 150mV 150mV 150mV 80% 85% 87% 88% 88% 89% (C.V. mode) Output 5V, 0~12.0A 12V, 0~8.5A 15V, 0~6.7A 24V, 0~4.2A 36V, 0~2.8A 48V, 0~2.1A 3 18~60W Single Output LED Power Supply Features • L PC: Universal AC input / Full range • Class 2 power unit / Pass LPS LPHC-18: 180~264VAC input only • Isolation class II, no F.G. LPL C -18: 90~132VAC input only • Cooling by free air convection • Fully encapsulated with IP67 level • 100% full load burn-in test • Protections: S hort circuit / Over voltage / • Low cost, high reliability Over temperature ( LPLC/LPHC-18 only ) • S uitable for LED-based decorative / architectural lighting, • Constant current design (C.C. mode) LED stage and theater lighting, and LED electronic displays • W ithstand 300VAC surge input for 5 seconds • 2 years warranty (except for LPHC/LPLC-18) LPHC-18 LPLC-18 LPC-20 LPC-35 LPC-60 INPUT OUTPUT AC input voltage range 90~132VAC 180~264VAC 90~264VAC AC inrush current (max.) Cold start, 40A at 115VAC Cold start, 50A at 230VAC Cold start, 70A at 230VAC Over voltage protection 105%~135% rated output voltage Withstand voltage I/P-O/P: 3kVAC Working temperature -30~+70OC Vibration 10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes Safety standards Design refer to UL1310, EN60950-1 UL1310, UL879 (LPC-20 only), TUV EN60950-1(LPC-20 only) approved EMC standards FCC part 15 class A (LPLC-18), EN55022 class A, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 UL rated, 18AWGx2C (30cm) UL rated, 18AWGx2C (60cm) UL rated, 18AWGx2C (60cm) 140x 30x 22 118x 35x 26 148x 40x 30 Connection Input Output Dimension (LxWxH)(mm) LPLC-18 Series (C.C. mode) (LVD) LPC-35 Series 200mV 85% LPC-35-1050 9~30V, 1050mA ±5% 200mV 85% LPC-35-1400 9~24V, 1400mA ±5% 200mV 85% Model No. 82% LPC-35-700 LPLC-18-700 6~25V, 700mA ±8% 250mV 80% R&N Effi. LPHC-18-350 6~48V, 350mA ±8% 300mV 80% LPHC-18-700 6~25V, 700mA ±8% 250mV 80% 4 (C.C. mode) (for 350mA) (for 700mA) Model No. Output Io Tol. R&N Effi. LPC-20-350 9~48V, 350mA ±5% 200mV 83% LPC-20-700 9~30V, 700mA ±5% 200mV 83% Output LPC-60 Series Model No. LPC-20 Series (for 1050mA & 1400mA) ±5% Effi. 300mV Io Tol. (for 700mA) 9~48V, 700mA R&N ±8% Output (C.C. mode) 162.5x 42.5x 32 Effi. Io Tol. Model No. UL rated, 16AWGx2C (60cm) R&N Output 6~48V, 350mA (C.C. mode) Cold start, 60A at 230VAC Io Tol. Model No. LPLC-18-350 LPHC-18 Series Cold start, 55A at 230VAC (C.C. mode) Output (for 1050mA & 1400mA) (for 1750mA) Io Tol. R&N Effi. LPC-60-1050 9~48V, 1050mA ±5% 200mV 87% LPC-60-1400 9~42V, 1400mA ±5% 200mV 85% LPC-60-1750 9~34V, 1750mA ±5% 200mV 87% 30~60W Single Output LED Power Supply Features •2Universal AC input / Full range • Class 2 power unit / Pass LPS •2Fully isolated plastic case with IP64 level • Isolation class II, no F.G. •2Built-in constant current limiting circuit with adjustable OCP level • Cooling by free air convection •2Protections: Short circuit / Over current / Over voltage • Suitable for economical LED indoor lighting and LED electronic •2Optional dimming function: 1.1~10VDC(D type) or PWM (P type) controlled displays •22 years warranty ELN-30 ELN-60 INPUT O UT P U T (standard) O UT P U T (Dimming Funct ion) AC input voltage range 90~264VAC ; 127~370VDC AC inrush current (max.) Cold start, 55A at 230VAC DC adjustment range ±10% rated output voltage Current adjustment range 75%~103% Over current protection 95%~110% constant current limiting, auto-recovery Over voltage protection Cold start, 60A at 230VAC Range 110%~150% rated output voltage Type Shut down o/p voltage, re-power on to recover Withstand voltage I/P-O/P: 3kVAC Working temperature -20~+60OC (refer to output derating curve) Vibration 10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes Safety standards UL1310 approved; Design refer to TUV EN60950-1 EMC standards EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 Input UL rated, SVT 18AWGx2C (32cm) UL rated, SVT 18AWGx2C (30cm) Output Without dimming: UL rated, SVT 18AWGx2C (32cm) With dimming(optional): UL2464 18AWGx4C (32cm) Without dimming: UL rated, SVT 18AWGx2C (30cm) With dimming(optional): UL2464 18AWGx4C (30cm) Dimension (LxWxH)(mm) 145x 47x 30 181x 61.5x 35 Packing 0.26kg ; 60pcs / 16.6kg 0.4kg ; 24pcs / 11.0kg Connection ELN-30 Series (for 48V only) ELN-60 Series (for 5~27V) Output Tol. R&N Effi. Model No. ELN-30-5 5V, 0~5.0A ±5% 80mV 75% ELN-60-9 ELN-30-9 9V, 0~3.4A ±5% 100mV 80% ELN-30-12 12V, 0~2.5A ±5% 120mV 82% ELN-30-15 15V, 0~2.0A ±5% 120mV 82% ELN-30-24 24V, 0~1.25A ±5% 150mV ELN-30-27 27V, 0~1.12A ±5% 150mV ELN-30-48 48V, 0~0.63A ±5% 250mV Model No. ► ►Dimming (for 48V only) Output (for 9~27V) Tol. R&N Effi. 9V, 0~5.0A ±5% 120mV 82% ELN-60-12 12V, 0~5.0A ±5% 120mV 85% ELN-60-15 15V, 0~4.0A ±5% 150mV 86% 85% ELN-60-24 24V, 0~2.5A ±5% 150mV 87% 85% ELN-60-27 27V, 0~2.3A ±5% 200mV 87% 87% ELN-60-48 48V, 0~1.3A ±5% 250mV 88% Control (optional) Through the dimming function, output current of D Type : 1.1~10Vdc external control signal PWM control signal V DIM+ ELN series can be adjusted to reduce the energy consumption or adjust the brightness of LEDs connecting to it. Two kinds of control signal are P Type : Vdc ELN Control input + f: 100Hz ~ 3KHz f 10V accepted: 1.1~10VDC (D-type option) or PWM signal (P-type option). Vdc 1.1~10V DIM- Order No.: ELN- 30 - 5 D t1 Duty= t2 t1 , 0~100% t1+t2 f Low: 0V High: 10V Order No.: ELN- 30 - 5 P 5 16~ 60W Single Ou t pu t AC Di m m abl e Pow e r Un i t Features • I P30 design • C lass 2 power unit / Pass LPS (PCD-16/25) •2Isolation class II, no F.G. • P rotections: Short circuit / Over temperature • C ooling by free air convection • 3 years warranty •AC phase-cut dimming, work with leading edge and trailing edge TRIAC dimmers •PCD-16/25: 115VAC or 230VAC input PCD-40/60: 230VAC input only • B uilt-in active PFC function • F ully isolated plastic case • C onstant current design PCD-16/25 PCD-40/60 NE W INPUT (A t y p e ) INPUT OUTPUT (B t y p e ) AC input voltage range 115VAC (90~135VAC) or 230VAC (180~295VAC) 230VAC (180~295VAC) AC inrush current (max.) Cold start, 10A at 230VAC PCD-40: Cold start, 11A at 230VAC PCD-60: Cold start, 13A at 230VAC Withstand voltage I/P - O/P: 3.75kVAC Working temperature -30~+60ºC (refer to output derating curve) Safety standards UL8750 (PCD-16/25 only), ENEC EN61347-1, EN61347-2-13, EN62384(B-Type only) approved (PCD-40/60 pending) EMC standards A-Type: FCC part 18 non-consumer equipment B-Type: EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Connection Input A-Type: UL1430 18AWGx2C (7.5cm); B-Type: NISPT-1 18AWGx2C (7.5cm) Output UL1430 18AWGx2C (15cm) Dimension (LxWxH)(mm) PCD-16 Series Mod e l N o . PCD-16-350 84x 57x 29.5 (for 350mA) (for 700~1400mA) O ut p ut 24~48V, 350mA 128x 60x 31.5 (B Type) (A Type) Io Tol . ±5% R& N 4.6V (B Type) PCD-60 Series ENEC/CB/CE pending E ffi. Model No. Ou tpu t Io T ol. R&N 82.0% PCD-60-500B 65~115V, 500mA ±5% 10.2V 87% PCD-60-700B 50~86V, 700mA ± 5% 5.6V 86% ± 5% 3.8V 86% E f f i. PCD-16-700 16~24V, 700mA ±5% 2.7V 81.0% PCD-60-1050B 34~57V, 1050mA PCD-16-1050 12~16V, 1050mA ±5% 2.2V 80.5% PCD-60-1400B 25~43V, 1400mA ±5% 3.4V 85% PCD-16-1400 8~12V, 1400mA ±5% 2.0V 80.0% PCD-60-1750B 20~34V, 1750mA ±5% 3.3V 85% = A o r B-T y p e ; A -T y pe: 90~135VAC , B-Type: 180~295V AC PCD-25 Series Mod e l N o . PCD-25-350 (for 350/700mA) (for 1050/1400mA) (B Type) (A Type) (B Type) O ut put Io Tol . R& N Effi. 40~58V, 350mA ±5% 4.6V 82.0% PCD-25-700 24~36V, 700mA ±5% 2.7V 81.0% PCD-25-1050 16~24V, 1050mA ±5% 2.2V 80.5% PCD-25-1400 12~18V, 1400mA ±5% 2.0V 80.0% = A o r B-T y p e ; A -T y pe: 90~135VAC , B-Typ e: 180~295V AC PCD-40 Series Mod e l N o . 6 -30~+50ºC (refer to output derating curve) ENEC/CB/CE pending O ut put Io Tol . R& N E ffi. PCD-60-2000B 18~30V, 2000mA ± 5% 2.4V 85% PCD-60-2400B 15~25V, 2400mA ± 5% 2.4V 84% ► ►Dimmer Compatibility Chart Ma n u fa c tu rer Dimmer Model LUTRON SKYLARK SF-12P-277 (277VAC / 60Hz) LUTRON DVF-103P-277 (277VAC / 60Hz) LUTRON SKYLARK SF-10P (120VAC / 60Hz) LUTRON SKYLARK S-600P (120VAC / 60Hz) LUTRON SKYLARK DVF-103P (120VAC / 60Hz) LEVITON ILLUMATECH TM Cat.No.IP106 (120VAC / 60Hz) LEVITON SURESLIDE TM Cat.No.6633-P LEVITON SURESLIDE TM Cat. NO.6615-P (120VAC / 60Hz) (120VAC / 60Hz) JUNG Licht-Management 225 T DE JUNG Licht-Management 225 NV DE (230VAC / 50Hz) (230VAC / 50Hz) PCD-40-350B 65~115V, 350mA ±5% 9.5V 87% BERKER Tronic-Drehdimmer 286710 (230-240VAC / 50Hz) PCD-40-500B 45~80V, 500mA ±5% 5.0V 87% BE LICHTREGLER T39.01 (230VAC / 50Hz) BE LICHTREGLER T46 (230VAC / 50Hz) CLIPSAL 32E450UDM (220-240VAC / 50Hz) CLIPSAL NO 32E450TM (220-240VAC / 50Hz) PCD-40-700B 34~57V, 700mA ±5% 3.1V 86% PCD-40-1050B 22~38V, 1050mA ±5% 2.6V 86% PCD-40-1400B 17~29V, 1400mA ±5% 2.5V 85% PCD-40-1750B 13~23V, 1750mA ±5% 2.4V 85% ► Conduction angle: 30 degrees (min.) / 180 degrees (max.) ► For PCD-16/25/40/60 only 16~ 60 W Single O u t pu t wi t h PFC Features • C lass 2 power unit / Pass LPS (PLD-16/25) •PLD-25: Universal AC input (up to 295VAC) / Full range •2Isolation class II, no F.G. PLD-16: 115VAC or 230VAC input • P rotections: Short circuit / Over temperature PLD-40/60: 230VAC input only •Built-in active PFC function • S uitable for indoor LED lighting applications • F ully isolated plastic case • C ooling by free air convection • C onstant current design • 3 years warranty • I P30 design PLD-25 PLD-16 PLD-40 PLD-60 NE W INP UT (A-Type) INP UT OUTPUT ( B-Type & PLD-25) AC input voltage range 115VAC (90~135VAC) or 90~295VAC 230VAC (180~295VAC) 230VAC (180~295VAC) AC inrush current (max.) Cold start, 20A at 230VAC Cold start, 25A at 230VAC Withstand voltage I/P - O/P: 3.75kVAC Short circuit protection Hiccup mode, auto-recovery Over Temp. protection 95ºC± 10ºC (RTH1) shut down o/p voltage, re-power on to recover 105ºC± 5ºC (STW1) shut down o/p voltage, auto-recovery Working temperature -30~+50ºC -30~+50ºC Safety standards UL8750 (PLD-16/25), ENEC EN61347-1, EN61347-2-13, EN62384 (except for A-Type) approved (PLD-40/60 pending) EMC standards A-Type & PLD-25: FCC part 18 non-consumer equipment B-Type & PLD-25: EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4,2,3,4,5,6,8,11, EN61547 Connection Cold start, 15A at 230VAC -30~+60ºC Input A-Type: UL1430 18AWGx2C (7.5cm) B-Type & PLD-25: NISPT-1 18AWGx2C (7.5cm) Output UL1430 18AWGx2C (15cm) Dimension (LxWxH)(mm) PLD-16 Series Mod e l N o . 84x 57x 29.5 (for 350mA) O ut p ut 128x 60x 31.5 (for 700~1400mA) (B Type) (A Type) (B Type) Io Tol . R& N E ffi. PLD-16-350 24~48V, 350mA ±5% 4.6V 84.5% PLD-16-700 16~24V, 700mA ±5% 2.7V 84.5% PLD-16-1050 12~16V, 1050mA ±5% 2.2V 84.0% PLD-16-1400 8~12V, 1400mA ±5% 2.0V 82.5% PLD-40 Series ENEC/CB/CE pending Ou tpu t Io T ol. R&N E f f i. PLD-40-350B 65~115V, 350mA ±5% 9.5V 88% PLD-40-500B 45~80V, 500mA ±5% 5.0V 88% Model No. PLD-40-700B 34~57V, 700mA ±5% 3.1V 87% PLD-40-1050B 22~38V, 1050mA ±5% 2.6V 87% PLD-40-1400B 17~29V, 1400mA ± 5% 2.5V 86% PLD-40-1750B 13~23V, 1750mA ± 5% 2.4V 86% = A o r B-T y p e ; A -T y pe: 90~135VAC , B-Type: 180~295V AC PLD-25 Series Mod e l N o . PLD-25-350 (for 350/700mA) O ut put 36~58V, 350mA PLD-60 Series (for 1050/1400mA) Io Tol . ±5% R& N 4.6V Effi. 85% PLD-25-700 24~36V, 700mA ±5% 2.7V 86% PLD-25-1050 16~24V, 1050mA ±5% 2.2V 85% PLD-25-1400 12~18V, 1400mA ±5% 2.0V 84% ENEC/CB/CE pending Ou tpu t Io Tol. R&N E f f i. PLD-60-500B 65~115V, 500mA ±5% 10.2V 88% Model No. PLD-60-700B 50~86V, 700mA ±5% 5.6V 87% PLD-60-1050B 34~57V, 1050mA ±5% 3.8V 87% PLD-60-1400B 25~43V, 1400mA ± 5% 3.4V 86% PLD-60-1750B 20~34V, 1750mA ± 5% 3.3V 86% PLD-60-2000B 18~30V, 2000mA ±5% 2.4V 86% PLD-60-2400B 15~25V, 2400mA ±5% 2.4V 85% 7 12~ 40 W Single O u t pu t wi t h PFC Features • Universal AC input (up to 295VAC) / Full range • Isolation class II, no F.G. • Built-in active PFC function • Cooling by free air convection •2Protections: Short circuit / Over temperature(PLM-40) • Low cost, high reliability • Fully isolated plastic case • Suitable for indoor LED lighting applications • Constant current design •22 years warranty • IP30 design PLM-12 PLM-25 PLM-40 De U ve nd lop er me nt De U ve nd lop er me nt AC input voltage range 90~295VAC; 127~417VDC AC inrush current (max.) Cold start, 40A at 230VAC Setup time 2000ms at full load and 230VAC Short circuit protection Hiccup mode, auto-recovery Over temperature (PLM-40) 95ºC ±10ºC (RTH1) shut down o/p voltage, re-power on to recover Withstand voltage I/P-O/P: 3.75kVAC Working temperature -30~+45ºC (refer to output derating curve) Safety standards Design refer to UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 EMC standards Design refer to EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 1500ms at full load and 230VAC -30~+50ºC (refer to output derating curve) Connection (Input / Output) 2+2P push terminal block Dimension (LxWxH)(mm) 145x 38x 22 PLM-12 Series UL/CUL/ENEC/CB/CE pending Output Io Tol. R&N Effi. PLM-12-350 18~36V, 350mA ±5% 3.6V 85% PLM-12-500 12~24V, 500mA ±5% 2.4V 84% PLM-12-700 9~18V, 700mA ±5% 1.8V 83% PLM-12-1050 6~12V, 1050mA ±5% 1.2V 82% Model No. PLM-25 Series PLM-40 Series Model No. UL/CUL/ENEC/CB/CE pending Output Io Tol. R&N Effi. PLM-40-350 53~105V, 350mA ±5% 10V 88% PLM-40-500 40~80V, 500mA ±5% 8V 87% PLM-40-700 28~55V, 700mA ±5% 6V 86% PLM-40-1050 19~38V, 1050mA ±5% 4V 86% PLM-40-1400 15~29V, 1400mA ±5% 3V 85% PLM-40-1750 12~23V, 1750mA ±5% 2.5V 85% UL/CUL/ENEC/CB/CE pending Output Io Tol. R&N Effi. PLM-25-350 36~72V, 350mA ±5% 7.2V 88% PLM-25-500 25~50V, 500mA ±5% 5.0V 87% PLM-25-700 18~36V, 700mA ±5% 3.6V 86% PLM-25-1050 12~24V, 1050mA ±5% 2.4V 86% Model No. 8 175x 42x 24 16~ 90W Single O u t pu t wit h PFC Features • Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC function • Fully isolated plastic case • Isolation class II, no F.G. • Class 2 power unit / Pass LPS LPF-16(D)/25(D) • Built-in 3 in 1 dimming function (1~10VDC, PWM signal or resistance) for D type • Fully encapsulated with IP67 level [optional for LPF-16(D)] • Cooling by free air convection • Suitable for LED lighting and moving sign applications • Suitable for dry, damp, and wet location • 3 years warranty LPF-40(D)/60(D) LPF-90(D) NE W INPUT O UT PU T (Non-Dimming Function) O UT PU T (Dimming Function) AC input voltage range 90~305VAC ; 127~431VDC AC inrush current (max.) LPF-16(D): Cold start, 45A LPF-25(D): Cold start, 50A Over current protection 95% ~108% constant current, auto-recovery Over voltage protection 110%~150% rated output voltage Withstand voltage I/P - O/P: 3.75kVAC Working temperature -35~+70ºC Safety standards UL8750, ENEC EN61347-1, EN61347-2-13, EN62384, PSE J61347-1, J61347-2-13 approved for LPF-16(D)/25(D); UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved for LPF-40(D)/60(D)/90(D) EMC standards Input EN55015, EN61547, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 UL rated, SJTW 18AWGx2C (30cm) Connection Output Dimension (LxWxH)(mm) LPF-16 LPF-25 -12 -15 -20 -24 -30 -36 -42 -48 -54 LPF-40 -12 -15 -20 -24 -30 -36 -42 -48 -54 LPF-40/60: UL rated, SVT 18AWGx2C (30cm) LPF-40D/60D: UL2464 18AWGx2C(30cm)+22AWGx2C (30cm) LPF-90: UL rated, SVT 18AWGx2C (30cm) LPF-90D: UL2464 18AWGx4C (30cm) 148x 40x 32 162.5x 43x 32 161x 61x 36 -12 -15 -20 PS E TUV Rheinland Product Safety Model No. O u t put Tol . R& N E ffi. 12V, 0~1.34A 15V, 0~1.07A 20V, 0~0.80A 24V, 0~0.67A 30V, 0~0.54A 36V, 0~0.45A 42V, 0~0.39A 48V, 0~0.34A 54V, 0~0.30A ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% 150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV 83.0% 83.0% 84.5% 84.5% 84.5% 85.0% 85.0% 85.0% 84.5% TUV Rheinland Product Safety PS E O u t put Tol . R& N E ffi. 12V, 0~2.10A 15V, 0~1.67A 20V, 0~1.25A 24V, 0~1.05A 30V, 0~0.84A 36V, 0~0.70A 42V, 0~0.60A 48V, 0~0.53A 54V, 0~0.47A ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% 150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV 84.0% 84.0% 85.0% 85.5% 85.5% 85.5% 85.5% 86.0% 86.0% Series Mod e l N o . LPF-40 LPF-40 LPF-40 LPF-16/25: UL rated, SVT 18AWGx2C (30cm) LPF-16D/25D: UL rated, SJTW 18AWGx4C (30cm) Series Mod e l N o . LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 Cold start, 55A at 230VAC -40~+70ºC (refer to output derating curve) Series Mod e l N o . LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-40(D): Cold start, 50A LPF-60(D): Cold start, 55A (for 48~54V) TUV Rheinland Product Safety (for 12~42V) PS E O u t put Tol . R& N E ffi. 12V, 0~3.34A 15V, 0~2.67A 20V, 0~2.00A ±4.0% ±4.0% ±4.0% 150mV 150mV 150mV 84.0% 85.0% 86.0% LPF-40 LPF-40 LPF-40 LPF-40 LPF-40 LPF-40 LPF-60 -24 -30 -36 -42 -48 -54 LPF-90 -12 -15 -20 -24 -30 -36 -42 -48 -54 R&N E f f i. 150mV 200mV 250mV 250mV 250mV 350mV 87.0% 88.0% 88.0% 88.5% 89.0% 89.0% (for 48~54V) -15 -20 -24 -30 -36 -42 -48 -54 TUV Rheinland Product Safety (for 12~42V) PS E Ou tpu t T ol. R &N E f f i. 12V, 0~5.00A 15V, 0~4.00A 20V, 0~3.00A 24V, 0~2.50A 30V, 0~2.00A 36V, 0~1.67A 42V, 0~1.43A 48V, 0~1.25A 54V, 0~1.12A ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% 150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV 86% 87% 88% 89% 90% 90% 90% 90% 90% Series Model No. LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 T ol. ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% Series Model No. LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 Ou tpu t 24V, 0~1.67A 30V, 0~1.34A 36V, 0~1.12A 42V, 0~0.96A 48V, 0~0.84A 54V, 0~0.76A (for 48~54V) TUV Rheinland Product Safety (for 15~42V) PS E Ou tpu t Tol. R &N E f f i. 15V, 0~5.00A 20V, 0~4.50A 24V, 0~3.75A 30V, 0~3.00A 36V, 0~2.50A 42V, 0~2.15A 48V, 0~1.88A 54V, 0~1.67A ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV 89.0% 89.5% 90.0% 90.5% 90.5% 90.5% 90.5% 90.5% = Blank, D ; Blank: without dimming function , D: with dimming function 9 30~ 96W Single O u t pu t wit h PFC Features • Universal AC input / Full range • Isolation class II, no F.G. for PLC-30 • Fully isolated plastic case with screw terminal style of I/O • Cooling by free air convection • Built-in constant current limiting circuit (C.V.+C.C. mode) • Protections: Short circuit / Over current / Over voltage / • Adjustable output voltage and current level • Built-in active PFC function, PF>0.9 for 75% of load or higher • High efficiency up to 89% • Suitable for LED lighting and moving sign applications • Class 2 power unit / Pass LPS • 2 years warranty PLC-30 PLC-45 PLC-100 PLC-60 AC input voltage range 90~264VAC ; 127~370VDC AC inrush current (max.) Cold start, 35A at 230VAC Cold start, 40A at 230VAC DC adjustment range 90%~110% rated output voltage 85%~100% rated output voltage Current adjustment range 75%~103% Over current protection 100%~110% constant current limiting, auto-recovery Over voltage protection 110%~155% rated output voltage 115%~140% rated output voltage 107%~135% rated output voltage Setup time 2000ms at full load and 230VAC 1500ms at full load and 230VAC Withstand voltage I/P-O/P: 3.75kVAC I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC Working temperature -30~+50OC (refer to output derating curve) Safety standards UL1310, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; TUV EN60950-1 approved for PLC-100 only EMC standards EN55015, EN55022 class B (PLC-45/60/100), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Connection (Input / Output) 2+2P screw terminal block 3+2P screw terminal block Dimension (LxWxH)(mm) 160x 46x 30 181.5x 62x 35 200.5x 69.5x 35 Packing 0.2kg ; 70pcs / 15kg 0.41kg ; 30pcs / 13.3kg 0.52kg ; 25pcs / 14kg PLC-30 Series (for 48V only) (for 9~36V) 75%~100% TUV Rheinland Product Safety 95%~110% constant current limiting, auto-recovery PLC-60 Series PS E 95%~102% constant current limiting, auto-recovery 1200ms at full load and 230VAC (for 12~36V) (for 48V only) PS E Output Tol. R&N Effi. Model No. Tol. R&N Effi. ±10% 2.6V 80.0% PLC-60-12 12V, 0~5.0A ±10% 2.0V 85.0% PLC-30-12 12V, 0~2.5A ±10% 2.0V 82.5% PLC-60-15 15V, 0~4.0A ±10% 2.4V 86.0% PLC-30-15 15V, 0~2.0A ±10% 2.6V 83.5% PLC-60-20 20V, 0~3.0A ±10% 1.8V 87.5% PLC-30-20 20V, 0~1.5A ±10% 2.6V 84.0% PLC-60-24 24V, 0~2.5A ±10% 2.4V 87.0% PLC-30-24 24V, 0~1.25A ±10% 2.4V 84.0% PLC-60-27 27V, 0~2.3A ±10% 2.7V 88.0% PLC-30-27 27V, 0~1.12A ±10% 2.3V 84.5% PLC-60-36 36V, 0~1.7A ±10% 3.6V 89.0% PLC-30-36 36V, 0~0.84A ±10% 3.6V 85.0% PLC-60-48 48V, 0~1.3A ±10% 4.6V 89.0% PLC-30-48 48V, 0~0.63A ±10% 3.7V 85.5% PLC-45 Series (for 48V only) (for 12~36V) TUV Rheinland Product Safety Output TUV Rheinland Product Safety 9V, 0~3.3A Model No. PLC-30-9 PLC-100 Series PS E TUV Rheinland Product Safety (for 12~36V) (for 48V only) PS E Tol. R&N Effi. Model No. Output Tol. R&N Effi. PLC-45-12 12V, 0~3.8A ±10% 2.0V 83.5% PLC-100-12 12V, 0~5.0A ±3% 150mV 83.0% PLC-45-15 15V, 0~3.0A ±10% 2.4V 85.0% PLC-100-15 15V, 0~5.0A ±3% 150mV 85.0% 20V, 0~4.8A ±3% 150mV 88.5% Model No. 10 Over temperature • 100% full load burn-in test Output PLC-45-20 20V, 0~2.3A ±10% 1.8V 86.5% PLC-100-20 PLC-45-24 24V, 0~1.9A ±10% 2.7V 86.5% PLC-100-24 24V, 0~4.0A ±3% 150mV 88.5% PLC-45-27 27V, 0~1.7A ±10% 2.7V 86.5% PLC-100-27 27V, 0~3.55A ±3% 150mV 88.0% PLC-45-36 36V, 0~1.25A ±10% 3.6V 87.5% PLC-100-36 36V, 0~2.65A ±2% 150mV 88.0% PLC-45-48 48V, 0~0.95A ±10% 4.6V 87.5% PLC-100-48 48V, 0~2.0A ±2% 200mV 88.5% 20~96W Single Output with PFC Features •2Universal AC input (up to 295VAC) / Full range •2Fully isolated plastic case with IP64 level •2Built-in active PFC function, PF>0.9 for 75% of load or higher •2Protections: Short circuit / Over current / Over voltage / Over temperature •2Built-in constant current limiting circuit (C.V.+C.C. mode) •2Class 2 power unit / Pass LPS PLN-20 •2Isolation class II, no F.G. for PLN-20/30 •2User adjustable output voltage (except for PLN-20) and current protection level •2Cooling by free air convection •2Suitable for LED lighting and moving sign applications •22 years warranty PLN-30 PLN-45/60 PLN- 100 I NP UT PLN-20 PLN-30 PLN-45/60/100 O U T P UT PLN-20 PLN-30/45/60/100 AC input voltage range AC inrush current (max.) 90~295VAC ; 127~417VDC 90~277VAC; 127~392VDC Cold start, 35A at 230VAC Cold start, 40A at 230VAC DC adjustment range None 95%~108% rated output voltage 85%~100% rated output voltage Current adjustment range 75%~100% 95%~110% constant current limiting, auto-recovery 75%~103% 100%~110% constant current limiting, auto-recovery 95%~110% constant current limiting, auto-recovery 95%~102% constant current limiting, auto-recovery 105%~142% rated output voltage 110%~155% rated output voltage 115%~140% rated output voltage 107%~135% rated output voltage 2300ms(setup time) at full load and 230VAC, no hold up time I/P-O/P: 3.75kVAC -30~+60 O C 2000ms(setup time) at 1500ms(setup time) at 1200ms, 80ms, 60ms full load and 230VAC, full load and 230VAC, at full load and 230VAC no hold up time no hold up time I/P-O/P: 3.75kVAC I/P-FG: 2kVAC O/P-FG: 0.5kVAC -30~+50 O C (refer to output derating curve) Over current protection Over voltage protection Setup, rise, hold up time Withstand voltage Working temperature Safety standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved for PLN-20 UL879, UL1310, UL8750(PLN-45/60), TUV EN61347-1, EN61347-2-13,PSE J61347-1, J61347-2-13 approved for PLN-30/45/60 UL879, UL1310, UL8750, TUV EN61347-1, EN61347-2-13, EN60950-1, PSE J61347-1, J61347-2-13 approved for PLN-100 EMC standards EN55015, EN55022 class B (PLN-60/100 only), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Input Output Dimension (LxWxH) (mm) Connection UL rated, UL1015 18AWGx2C (32cm) UL rated, SVT 18AWGx2C (32cm) UL rated, SVT 18AWGx3C (30cm) UL rated, SVT 18AWGx3C (31cm) UL rated, SVT 18AWGx2C (30cm) UL rated, SVT 18AWGx2C (31cm) 148.5x 38.5x 28 145x 47x 30 181x 61.5x 35 200x 70.5x 35 PLN-20 Series Model No. TUV Rheinland Product Safety Output PS E Tol. R&N Effi. PLN-20-12 12V, 0~1.6A ±10% 2.5V 80.0% PLN-20-18 18V, 0~1.1A ±10% 3.0V 81.0% PLN-20-24 24V, 0~0.8A ±10% 3.0V 82.0% PLN-20-36 36V, 0~0.55A ±10% 3.0V 83.0% PLN-20-48 48V, 0~0.42A ±10% 3.8V PLN-30 Series Model No. PLN-30-9 PLN-30-12 PLN-30-15 PLN-30-20 PLN-30-24 PLN-30-27 PLN-30-36 PLN-30-48 PLN-45 Series Model No. PLN-45-12 PLN-45-15 TUV Rheinland Product Safety (for 9~36V) (for 48V only) (for 9~36V) Output 9V, 0~3.3A 12V, 0~2.5A 15V, 0~2.0A 20V, 0~1.5A 24V, 0~1.25A 27V, 0~1.12A 36V, 0~0.84A 48V, 0~0.63A (for 48V only) Output 12V, 0~3.8A 15V, 0~3.0A Tol. ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10% R&N 2.6V 2.0V 2.6V 2.6V 2.6V 2.3V 4.5V 3.7V Effi. 80.0% 82.5% 83.5% 84.0% 84.0% 84.5% 85.0% 85.5% TUV Rheinland Product Safety (for 12~36V) Tol. ±10% ±10% 83.5% PS E R&N 2.0V 2.4V PS E Effi. 83.5% 85.0% Model No. PLN-45-20 PLN-45-24 PLN-45-27 PLN-45-36 PLN-45-48 Output 20V, 0~2.3A 24V, 0~1.9A 27V, 0~1.7A 36V, 0~1.25A 48V, 0~0.95A PLN-60 Series Model No. PLN-60-12 PLN-60-15 PLN-60-20 PLN-60-24 PLN-60-27 PLN-60-36 PLN-60-48 Model No. PLN-100-12 PLN-100-15 PLN-100-20 PLN-100-24 PLN-100-27 PLN-100-36 PLN-100-48 (for 48V only) Output 12V, 0~5.0A 15V, 0~4.0A 20V, 0~3.0A 24V, 0~2.5A 27V, 0~2.3A 36V, 0~1.7A 48V, 0~1.3A PLN-100 Series Tol. ±10% ±10% ±10% ±10% ±10% Tol. ±10% ±10% ±10% ±10% ±10% ±10% ±10% PS E R&N 2.0V 2.4V 1.8V 2.7V 2.7V 3.6V 4.6V (for 12~36V) Tol. ±3% ±3% ±3% ±3% ±3% ±2% ±2% Effi. 86.5% 86.5% 86.5% 87.5% 87.5% TUV Rheinland Product Safety (for 12~36V) (for 48V only) Output 12V, 0~5.0A 15V, 0~5.0A 20V, 0~4.8A 24V, 0~4.0A 27V, 0~3.55A 36V, 0~2.65A 48V, 0~2.0A R&N 1.8V 2.7V 2.7V 3.6V 4.6V Effi. 85.0% 86.0% 87.5% 87.0% 88.0% 89.0% 89.0% TUV Rheinland Product Safety R&N 150mV 150mV 150mV 150mV 150mV 150mV 200mV PS E Effi. 83.0% 85.0% 88.5% 88.5% 88.0% 88.0% 88.5% 11 40~80W Single Output with PFC Features •2Universal AC input (up to 305VAC) / Full range • Suitable for dry, damp location •2Fully isolated plastic case with IP64 level • Suitable for LED lighting and moving sign applications • Built-in active PFC function, PF> 0.9 for 60% of load or higher • Multiple models for choice: A-Type: IP64 rated. Output voltage and constant current level • Protections: can be adjusted through internal potentiometer Short circuit / Over current / Over voltage / Over temperature B-Type: IP64 rated and built-in 3 in 1 dimming function • Built-in constant current limiting circuit (C.V.+C.C. mode) (1-10VDC, PWM signal, or resistance) • Class 2 power unit / Pass LPS • 3 years warranty • High efficiency up to 91% • Cooling by free air convection HLN-40H HLN-60H HLN-80H INPUT B A B A OUTPUT AC input voltage range 90~305VAC; 127~431VDC AC inrush current (max.) Cold start, 50A at 230VAC DC adjustment range ±10% rated output voltage (A-Type only) Current adjustment range 60%~100% Over current protection 95%~108% constant current limiting, auto-recovery Over voltage protection 109%~150% rated output voltage Setup, rise, hold up time 1000ms, 80ms, 16ms at full load and 230VAC Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC Working temperature -40~+50 O C (refer to output derating curve) Safety standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1for HLN-40H/60H EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Connection Cold start, 55A at 230VAC Input UL rated, SVT 18AWGx3C (30cm) Output A-Type: UL rated, SVT 18AWGx2C (30cm) ; B-Type: UL rated, SVT 18AWGx4C (30cm) Dimension (LxWxH) (mm) HLN-40H Series Model No. 161x 61.5x 35 (for 48~54V) Output (for 12~42V) Tol. 181x 61.5x 35 TUV Rheinland Product Safety PS E R&N Model No. Output Tol. R&N Effi. Effi. HLN-60H-36 A 36V, 0~1.70A ±1.0% 200mV 90.0% HLN-40H-12 A 12V, 0~3.33A ±2.5% 150mV 86.5% HLN-60H-42 A 42V, 0~1.45A ±1.0% 300mV 90.0% HLN-40H-15 A 15V, 0~2.67A ±2.0% 150mV 86.5% HLN-60H-48 A 48V, 0~1.30A ±1.0% 300mV 90.5% HLN-40H-20 A 20V, 0~2.00A ±1.0% 150mV 87.5% HLN-60H-54 A 54V, 0~1.15A ±1.0% 300mV 90.5% HLN-40H-24 A 24V, 0~1.67A ±1.0% 150mV 88.0% = A or B HLN-40H-30 A 30V, 0~1.34A ±1.0% 200mV 88.5% HLN-40H-36 A 36V, 0~1.12A ±1.0% 200mV 88.5% HLN-40H-42 A 42V, 0~0.96A ±1.0% 300mV 88.5% Model No. Output Tol. R&N Effi. HLN-40H-48 A 48V, 0~0.84A ±1.0% 300mV 89.0% HLN-80H-12 A 12V, 0~5.0A ±2.5% 150mV 88.0% HLN-40H-54 A 54V, 0~0.75A ±1.0% 300mV 89.0% HLN-80H-15 A 15V, 0~5.0A ±2.0% 150mV 89.0% HLN-80H-20 A 20V, 0~4.0A ±1.0% 150mV 90.0% HLN-80H-24 A 24V, 0~3.4A ±1.0% 150mV 90.5% HLN-80H-30 A 30V, 0~2.7A ±1.0% 200mV 91.0% HLN-80H-36 A 36V, 0~2.3A ±1.0% 200mV 91.0% HLN-80H-42 A 42V, 0~1.95A ±1.0% 200mV 91.0% HLN-80H-48 A 48V, 0~1.7A ±1.0% 200mV 91.0% HLN-80H-54 A 54V, 0~1.5A ±1.0% 200mV 91.0% = A or B HLN-60H Series 12 (for 48~54V) (for 15~42V) TUV Rheinland Product Safety R&N PS E Model No. Output Tol. Effi. HLN-60H-15 A 15V, 0~4.0A ±2.0% 150mV 87.0% HLN-60H-20 A 20V, 0~3.0A ±1.0% 150mV 88.5% HLN-60H-24 A 24V, 0~2.5A ±1.0% 150mV 89.0% HLN-60H-30 A 30V, 0~2.0A ±1.0% 200mV 89.5% HLN-80H Series = A or B (for 48~54V) (for 12~42V) TUV Rheinland Product Safety PS E 40~60W Multiple-Stage Output Current LED Power Supply Features LCM-40(DA) / 60(DA) NE W •2Output current level selectable by DIP switch •2180~295VAC input only •2Built-in active PFC function •2Protections: Short circuit / Over voltage / Over temperature •2Cooling by free air convection • Fully isolated plastic case • Class II power unit, no F.G. • IP20 design • Built-in 0~10Vdc and PWM signal dimming function (LCM-40/60) • Built-in DALI interface and push dimming function (LCM-40DA/60DA) • Built-in 12V/50mA auxiliary output • Temperature compensation function by external NTC • No load power consumption <1W (LCM-40/60) No load power consumption <1.2W (LCM-40DA/60DA) • Power supplies synchronization function up to 10 units • Suitable for indoor LED lighting applications • 3 years warranty AC input voltage range 180~295VAC; 254~417VDC AC inrush current (Typ.) Cold start, 20A at 230VAC Short circuit protection Constant current limiting, recovers automatically after fault condition is removed Over voltage protection LCM-40/40DA: 110~130VDC, LCM-60/60DA: 105~125VDC Over temp. protection Range O O 90 C ±10 C (RTH2) Type Shut down o/p voltage, re-power on to recover Setup, rise, hold up time 1000ms, 80ms, 16ms at full load and 230VAC Withstand voltage I/P-O/P: 3.75kVAC Working temperature O -30~+60 C (refer to output derating curve) Safety standards UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 approved DALI standards Comply with IEC62386-101, 102, 207 (LCM-40DA/60DA only) EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Dimension (LxWxH)(mm) 123.5x 81.5x 23 LCM-40(DA) Series O u tpu t Io T ol. R&N Effi. DI P S wi tc h 3 4 1 2 5 6 350mA , 2 ~ 1 0 0 V ----- ----- ----- ----- ----- ----- 500mA , 2 ~ 8 0 V ON ----- ----- ----- ----- ----- 600mA , 2 ~ 6 7 V ON ON ----- ----- ----- ----- ON ON ON ----- ----- ON 900mA , 2 ~ 4 5 V ON ON ON ON ----- ON 1050m A , 2 ~ 4 0 V ON ON ON ON ON ON 1 2 5 6 500mA , 2 ~ 9 0 V ----- ----- ----- ----- ----- ----- 600mA , 2 ~ 9 0 V ON ----- ----- ----- ----- ----- ON ON ----- ----- ----- ----- ON ON ON ----- ----- ON 1050m A , 2 ~ 5 7 V ON ON ON ON ----- ON 1400m A , 2 ~ 4 2 V ON ON ON ON ON ON 7 0 0 mA, 2~57V (Factory setting) ±5% 700mV 90.5% LCM-60(DA) Series O u tpu t 7 0 0 mA, 2~86V (Factory setting) 900mA , 2 ~ 6 7 V Io T ol. ±5% R&N 700mV Effi. 91.5% DI P S wi tc h 3 4 ► LCM- 40/6 0 are pri ma r y mod e ls w it h 0 ~ 1 0 V d c a n d P W M s i g n a l di m m i n g f u n c ti o n . ► LCM- 40DA /60DA ha v e D ALI int e r fa ce a nd p us h di m m i n g f u n c ti o n . 13 20~ 60W Single O u t pu t wit h PFC Features • Universal AC input / Full range • Class 2 power unit / Pass LPS • Protections: Short circuit / Over current / Over voltage / • Isolation class II, no F.G. for PLP-20 • Built-in constant current limiting circuit (C.V.+C.C. mode) Over temperature (PLP-20 only) • Built-in active PFC function, PF>0.9 for 75% of load or higher • Suitable for building in LED lighting systems • Cooling by free air convection • 2 years warranty PLP-30 PLP-20 AC input voltage range 90~277VAC; 127~392VDC AC inrush current (max.) Cold start, 25A at 230VAC Current adjustable range 75%~100% Over current Range protection Type 95%~110% PLP-45/60 90~264VAC; 127~370VDC PLP-45: Cold start, 30A at 230VAC PLP-60: Cold start, 35A at 230VAC 100%~110% Constant current limiting, auto-recovery Setup, rise, hold up time 2300ms, 200ms at full load and 230VAC, no hold up time 1200ms(setup time) at full load and 230VAC, no hold up time Withstand voltage I/P-O/P: 3.75kVAC I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC Working temperature O -30~+60 C -30~+70OC (refer to output derating curve) Safety standards UL8750, TUV EN61347-1, EN61347-2-13 approved EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Connection UL1015 18AWGx2C (30cm) 3+2P / 3.96mm pitch, JST P/N: B3P / B2P-VH Dimension (LxWxH)(mm) 140x 32x 22 101.6x 50.8x 26.6 PLP-20 Series 1000ms(setup time) at full load and 230VAC, no hold up time 101.6x 50.8x 29.6 PLP-45 Series (for 48V only) (for 12/24V) Mod el N o . O u t put Tol . R& N E ffi. Model No. Ou tpu t Tol. R&N E f f i. PLP- 2 0 -1 2 1 2 V , 0 ~1. 6A ±10% 2. 5V 80.0 % P LP - 4 5- 12 12V , 0~3.8 A ±10% 4.2 V 86% PLP- 2 0-1 8 1 8 V , 0~1. 1A ±10% 3. 0V 81.0 % P LP - 4 5- 24 2 4V , 0~1.9 A ± 10% 3.8 V 89% PLP- 2 0-2 4 2 4 V , 0~0. 8A ±10% 3. 0V 82.0 % P LP - 45- 48 48V , 0~0.9 5A ± 10% 4.8 V 89% PLP- 2 0-3 6 3 6 V , 0~0. 55A ±10% 3. 0V 83.0 % PLP- 2 0-4 8 4 8 V , 0 ~0. 42A ±10% 3. 8V 83.5 % PLP-30 Series (for 48V only) PLP-60 Series (for 12/24V) (for 48V only) (for 12/24V) Mod el N o . O u t put Tol . R& N Effi. Model No. Ou tpu t T ol. R&N E f f i. PLP- 3 0-1 2 1 2 V , 0 ~2. 5A ±10% 2. 0V 83.0 % P LP - 60- 12 12V , 0~5.0 A ± 10% 4 .5 V 84% PLP- 3 0-2 4 2 4 V , 0 ~1. 3A ±10% 2. 4V 85.5 % P LP - 60- 24 24V , 0~2.5 A ± 10% 4 .5 V 88% PLP- 3 0-4 8 4 8 V , 0 ~ 0. 63A ±10% 4. 8V 86.5 % P LP - 60- 48 4 8V , 0~1.3 A ± 10% 4 .8 V 89% ► ►Special Symbols for EN61347-2-13 Protection against overheating to prevent the lamp controlgear case temperature under any conditions of use from exceeding the indicated value (110 C) 110 O F M Suitable for direct mounting on normally flammable surfaces, such as wood (>2mm) M LPS Based on VDE0710-14, can be installed inside a wooden material like wooden cabinet. The minimum distance between the product enclosure to wooden material in each side is defined. Limited power source o 14 tc: 80 C o ta: 40 C Full load operation up to 40 C with surface temperature of case < 80 OC SELV Vo< 120VDC can have this mark on the unit O 40~ 80W Single O u t pu t wit h PFC Features •2Universal AC input (up to 305VAC) / Full range • C lass 2 power unit / Pass LPS • P rotections: • C ooling by free air convection • S uitable for built-in LED lighting system Short circuit / Over current / Over voltage / Over temperature • B uilt-in 3 in 1 dimming function • B uilt-in active PFC, PF>0.95 (1~10VDC, PWM signal, or resistance) • O utput constant current level adjustable • 3 years warranty • B uilt-in constant current limiting circuit (C.V.+C.C. mode) HLP-40H HLP-60H HLP-80H AC input voltage range 90~305VAC ; 127~431VDC AC inrush current (max.) Cold start, 50A at 230VAC DC adjustment range ±10% rated output voltage Current adjustment range 60%~100% Over current protection 95%~108% constant current limiting, auto-recovery Over voltage protection 109%~145% rated output voltage Setup, rise, hold up time 1000ms, 80ms, 16ms at full load and 230VAC Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC Working temperature -40~+70 O C (refer to output derating curve) Safety standards UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to EN60335-1(HLP-40H/60H), UL60950-1, EN60950-1 80%~100% 1000ms, 200ms, 16ms at full load and 230VAC EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 EMC standards Connection Cold start, 55A at 230VAC Input Output Dimension (LxWxH) (mm) 6+6P/3.96mm pitch, JST P/N: B6P-VH 147x 53x 27 HLP-40H Series (for 48V/54V) 167x 53x 29.5 (for 12~42V) Model No. Output Tol. HLP-40H-12 12V, 0~3.33A ±2.5% 150mV 87.0% HLP-60H-36 HLP-40H-15 15V, 0~2.67A ±2.0% 150mV 87.0% HLP-60H-42 HLP-40H-20 20V, 0~2.00A ±1.0% 150mV 88.0% HLP-60H-48 HLP-40H-24 24V, 0~1.67A ±1.0% 150mV 88.0% HLP-60H-54 HLP-40H-30 30V, 0~1.34A ±1.0% 200mV 88.5% HLP-40H-36 36V, 0~1.12A ±1.0% 200mV 89.0% HLP-40H-42 42V, 0~0.96A ±1.0% 300mV 89.0% HLP-40H-48 48V, 0~0.84A ±1.0% 300mV 89.5% HLP-40H-54 54V, 0~0.75A ±1.0% 300mV 89.5% HLP-60H Series (for 48V/54V) R&N Effi. (for 12~42V) Model No. Output Tol. R&N Effi. 36V, 0~1.70A ±1.0% 200mV 90.0% 42V, 0~1.45A ±1.0% 300mV 90.0% 48V, 0~1.30A ±1.0% 300mV 90.5% 54V, 0~1.15A ±1.0% 300mV 90.5% HLP-80H Series Model No. (for 48V/54V) (for 12~42V) Output Tol. R&N Effi. HLP-80H-12 12V, 0~5.0A ±2.5% 150mV 87.5% HLP-80H-15 15V, 0~5.0A ±2.0% 150mV 88.5% HLP-80H-20 20V, 0~4.0A ±1.0% 150mV 89.5% HLP-80H-24 24V, 0~3.4A ±1.0% 150mV 90.0% Model No. Output Tol. Effi. HLP-80H-30 30V, 0~2.7A ±1.0% 200mV 90.0% HLP-60H-15 15V, 0~4.0A ±2.0% 150mV 88.0% HLP-80H-36 36V, 0~2.3A ±1.0% 200mV 90.0% HLP-60H-20 20V, 0~3.0A ±1.0% 150mV 89.0% HLP-80H-42 42V, 0~1.95A ±1.0% 200mV 90.0% HLP-60H-24 24V, 0~2.5A ±1.0% 150mV 89.5% HLP-80H-48 48V, 0~1.7A ±1.0% 200mV 90.0% HLP-60H-30 30V, 0~2.0A ±1.0% 200mV 90.0% HLP-80H-54 54V, 0~1.5A ±1.0% 200mV 90.0% R&N 15 60~96W Single Output with PFC Features •2Universal AC input (up to 295VAC) / Full range •2P rotections: Short circuit / Over current / Over voltage / Over temperature •2Built-in active PFC function, PF>0.9 for 75% of load or higher •2IP66 design •2Meet 4kV surge immunity level (IEC61000-4-5) •2Class 2 power unit / Pass LPS •2Cooling by free air convection •2Suitable for dry, damp, and wet location •2Suitable for LED lighting and moving sign applications •23 years warranty CEN-60/75 CEN-100 INPUT OUTPUT AC input voltage range 90~295VAC ; 127~417VDC AC inrush current (max.) Cold start, 45A at 230VAC DC adjustment range ±10% rated output voltage Current adjustment range 75%~100% Over current protection 95%~110% constant current limiting, auto-recovery Over voltage protection 110%~140% rated output voltage (RTH1) shut down o/p voltage, 85 re-power on to recover 100oC ±10oC (RTH1) shut down o/p voltage, re-power on to recover Setup time 1400ms at full load and 230VAC, no hold up time 3000ms at full load and 230VAC, no hold up time Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC Working temperature -30~+70OC (refer to output derating curve) Safety standards UL8750, UL879 (except for CEN-100), TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved Connection ±10oC EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Input UL rated, SJTW 18AWGx3C (30cm) Output UL rated, SVT 18AWGx2C (30cm) Dimension (LxWxH) (mm) 185x 62.5x 40.5 CEN-60 Series Model No. 195x 62.5x 40.5 TUV Rheinland Product Safety Output Tol. PS E R&N Effi. Model No. Output Tol. R&N Effi. 30V, 0~2.50A ±10% 3.0V 90% 90% CEN-60-12 12V, 0~5.0A ±10% 2.0V 86% CEN-75-30 CEN-60-15 15V, 0~4.0A ±10% 2.4V 87% CEN-75-36 36V, 0~2.10A ±10% 3.6V CEN-60-20 20V, 0~3.0A ±10% 1.8V 88% CEN-75-42 42V, 0~1.80A ±10% 4.0V 90% CEN-60-24 24V, 0~2.5A ±10% 2.4V 89% CEN-75-48 48V, 0~1.57A ±10% 4.6V 91% CEN-60-30 30V, 0~2.0A ±10% 3.0V 90% CEN-75-54 54V, 0~1.40A ±10% 5.0V 91% CEN-60-36 36V, 0~1.7A ±10% 3.6V 90% CEN-60-42 42V, 0~1.45A ±10% 4.0V 90% CEN-60-48 48V, 0~1.3A ±10% 4.6V 91% CEN-60-54 54V, 0~1.15A ±10% 5.0V 91% CEN-75 Series 16 110%~135% rated output voltage Over temp. protection EMC standards oC 65%~100% TUV Rheinland Product Safety PS E CEN-100 Series (for 48V/54V) (for 20~42V) TUV Rheinland Product Safety PS E Model No. Output Tol. R&N Effi. CEN-100-20 20V, 0~4.80A ±10% 2.0V 88% CEN-100-24 24V, 0~4.00A ±10% 2.7V 89% CEN-100-30 30V, 0~3.20A ±10% 3.0V 90% Model No. Output Tol. R&N Effi. CEN-100-36 36V, 0~2.65A ±10% 3.6V 90% CEN-75-15 15V, 0~5.00A ±10% 2.7V 87% CEN-100-42 42V, 0~2.28A ±10% 4.0V 90% CEN-75-20 20V, 0~3.75A ±10% 2.0V 88% CEN-100-48 48V, 0~2.00A ±10% 4.6V 91% CEN-75-24 24V, 0~3.15A ±10% 2.7V 89% CEN-100-54 54V, 0~1.77A ±10% 5.0V 91% 60~150W Single Output with PFC Features •2Universal AC input (up to 295VAC) / Full range •2Protections:  Short circuit / Over current / Over voltage / Over temperature •2Built-in active PFC function, PF>0.9 for 75% of load or higher •2IP67/IP65 design for indoor or outdoor installations (except for C-Type) •2Output current adjustable through output cable or internal potentiometer (CLG-150) •2Class 2 power unit / Pass LPS (CLG-60&100) •2Cooling by free air convection • Suitable for LED lighting, street lighting and moving sign applications C LG - 6 0 • Built-in constant current limiting circuit (C.V.+C.C. mode) •2Meet 4kV surge immunity level (IEC 61000-4-5) • Multiple models for CLG-150 : A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated. Constant current level adjustable through output cable C-Type: Non IP. Terminal block for I/O connection Blank-Type: IP67 rated. Cable for I/O connection • 3 years warranty C L G-1 0 0 C L G-1 5 0 INPUT B A C Blank OUTPUT Class 2 AC input voltage range AC inrush current (max.) DC adjustment range Current adjustment range Over current protection Over voltage protection Setup, rise, hold up time Withstand voltage Working temperature Safety standards EMC standards Input Connection Output Dimension (LxWxH)(mm) Packing Class 2 90~295VAC; 127~417VDC Cold start, 65A at 230VAC Fixed. Can be modified between 90%~110% (CLG-60) Can be adjusted between 85%~110% by internal potentiometer (A and C-Type) or 85%~100% (CLG-100) rated output voltage Fixed. Can be modified between 75%~103% Can be adjusted between 50%~100% by internal potentiometer rated output current (A and C-Type) or through output cable (B-Type) 95%~110% constant 95%~102% constant 95%~108% constant current limiting, auto-recovery current, auto-recovery current, auto-recovery 110%~140% rated output voltage 110%~145% rated output voltage 3000ms(setup time), 1200ms, 80ms, 60ms 3000ms, 80ms, 50ms at full load and 230VAC at full load and 230VAC no hold up time I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC -30~+70OC (refer to output derating curve) UL1310, UL8750, UL879, TUV EN61347-1, UL60950-1, UL1012, UL8750, TUV EN60950-1, EN61347-2-13, PSE J61347-1, EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13(option) approved; J61347-2-13(option, except for CLG-150 C-Type) TUV EN60950-1 for CLG-100 only approved EN55015, EN55022 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 UL rated, SJTW 18AWGx3C (30cm); Terminal block for C type UL rated, SJTW 18AWGx3C (30cm) A & Blank-Type : SJTW 14AWGx2C (30cm) UL rated, SVT 18AWGx2C (30cm) B-Type: SJTW 14AWGx2C (30cm)+18AWGx2C (30cm) C-Type: Terminal block 195.6x 61.5x 38.8 222.2x 68x 38.8 A/B/Blank-Type: 222.2x 68x 38.8; C-Type: 229x 68x 38.8 0.86kg ; 16pcs / 14.8kg 1.0kg ; 12pcs / 13kg 1.0kg ; 12pcs / 13kg Cold start, 35A at 230VAC Cold start, 40A at 230VAC CLG-60 Series (option) (for 48V only) (for 12~36V) Model No. Output Tol. R&N Effi. CLG-60-12 12V, 0~5.0A ±10% 2.0V 85.0% CLG-60-15 15V, 0~4.0A ±10% 2.4V 86.0% CLG-60-20 20V, 0~3.0A ±10% 1.8V 87.5% CLG-60-24 24V, 0~2.5A ±10% 2.7V 87.0% CLG-60-27 27V, 0~2.3A ±10% 2.7V 88.0% CLG-60-36 36V, 0~1.7A ±10% 3.6V 89.0% CLG-60-48 48V, 0~1.3A ±10% 4.6V 89.0% CLG-100 Series (option) (for 48V only) (for 12~36V) Model No. Output Tol. R&N Effi. CLG-100-12 12V, 0~5.00A ±3% 150mV 83.0% CLG-100-15 15V, 0~5.00A ±3% 150mV 85.0% CLG-100-20 20V, 0~4.80A ±3% 150mV 88.5% CLG-100-24 24V, 0~4.00A ±3% 150mV 88.5% Model No. Output Tol. R&N Effi. CLG-100-27 27V, 0~3.55A ±3% 150mV 88.0% CLG-100-36 36V, 0~2.65A ±2% 150mV 88.0% CLG-100-48 48V, 0~2.00A ±2% 200mV 88.5% CLG-150 Series (option) Model No. Output Tol. R&N Effi. CLG-150-12 A 12V, 0~11.0A ±2% 150mV 88% CLG-150-15 A 15V, 0~9.50A ±2% 150mV 88% CLG-150-20 A 20V, 0~7.50A ±2% 150mV 90% CLG-150-24 A 24V, 0~6.30A ±1% 150mV 90% CLG-150-30 A 30V, 0~5.00A ±1% 150mV 91% CLG-150-36 A 36V, 0~4.20A ±1% 150mV 91% CLG-150-48 A 48V, 0~3.20A ±1% 200mV 91% □= A, B, C or blank CLG-60-12/24/48, CLG-100-12/24/48 & CLG-150-12A/24A/36A/ 48A are our popular models. We will keep sufficient stock for prompt delivery of high quantity orders. 17 40~60W High Efficiency with PFC Features •2Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC, PF>0.9 for 60% of load or higher • High efficiency up to 90.5% • IP67 / IP65 design for indoor or outdoor installations • Output current adjustable through output cable or internal potentiometer • Cooling by free air convection • Suitable for dry, damp, and wet location • Suitable for LED lighting and street lighting applications • Meet 4kV surge immunity level (IEC61000-4-5) • Class 2 power unit • Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details. • 5 years warranty HLG-40H HLG-60H A INPUT B Blank/D OUTPUT 90~305VAC ; 127~431VDC AC input voltage range AC inrush current (max.) Cold start, 50A at 230VAC DC adjustment range ±10% rated output voltage (A-Type only) Current adjustment range 60%~100% Over current protection 95%~108% constant current limiting, auto-recovery Over voltage protection 109%~145% rated output voltage Setup, rise, hold up time 1000ms, 80ms, 16ms at full load and 230VAC Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC Working temperature -40~+70OC (refer to output derating curve) Safety standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 EMC standards Connection Cold start, 55A at 230VAC Input UL rated, SJTW 18AWGx3C (30cm) Output A/D/Blank-Type: SVT 18AWGx2C (30cm); B-Type: SVT 18AWGx2C (30cm)+UL2517 18AWGx2C (30cm) Dimension (LxWxH) (mm) HLG-40H Series (for 48V/54V) Model No. HLG-40H-12 A HLG-40H-15 A 171x 61.5x 36.8 Output 12V, 0~3.33A 15V, 0~2.67A Model No. (for 12~42V) Tol. ±2.5% ±2.0% R&N 150mV 150mV Output Tol. R&N Effi. Effi. HLG-60H-36 A 36V, 0~1.70A ±1.0% 200mV 90.0% 86.5% HLG-60H-42 A 42V, 0~1.45A ±1.0% 300mV 90.0% 86.5% HLG-60H-48 A 48V, 0~1.30A ±1.0% 300mV 90.5% HLG-60H-54 A 54V, 0~1.15A ±1.0% 300mV 90.5% HLG-40H-20 A 20V, 0~2.00A ±1.0% 150mV 88.0% HLG-40H-24 A 24V, 0~1.67A ±1.0% 200mV 88.0% HLG-40H-30 A 30V, 0~1.34A ±1.0% 200mV 88.5% HLG-40H-36 A 36V, 0~1.12A ±1.0% 200mV 88.5% HLG-40H-42 A 42V, 0~0.96A ±1.0% 200mV 88.5% HLG-40H-48 A 48V, 0~0.84A ±1.0% 300mV 89.5% HLG-40H-54 A 54V, 0~0.75A ±1.0% 300mV 89.5% = A, B, D or Blank ► ►Junction Box for HLG Series = A, B, D or Blank HLG-60H Series 18 (for 48V/54V) (for 15~42V) Model No. Output Tol. R&N Effi. HLG-60H-15 A 15V, 0~4.0A ±2.0% 150mV 87.5% HLG-60H-20 A 20V, 0~3.0A ±1.0% 150mV 89.0% HLG-60H-24 A 24V, 0~2.5A ±1.0% 150mV 89.5% HLG-60H-30 A 30V, 0~2.0A ±1.0% 200mV 90.0% • Optional junction box available for HLG-80H~320H series (A/B/Blank-Type only). Please contact MEAN WELL for details. • “UL8750 listed” safety & IP66 approved for HLG-80H- BL (modified by B-Type only) 80~120W High Efficiency with PFC Features •2Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC, PF>0.9 for 60% of load or higher • High efficiency up to 93.5% • IP67 / IP65 design for indoor or outdoor installations • Output current adjustable through output cable or internal potentiometer • Cooling by free air convection • Suitable for dry, damp, and wet location • Suitable for LED lighting and street lighting applications • Meet 4kV surge immunity level (IEC61000-4-5) • Class 2 power unit / Pass LPS (except for HLG-120H) • Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection BL-Type(option): for HLG-80H B-Type only, "UL8750 listed" safety & IP66 approved, contact MEAN WELL for details D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details • Optional CQC models available (HLG-100H/120H-A/Blank type) • 5 years warranty HLG-100H / HLG-120H HLG-80H INPUT A B Blank/D OUTPUT 90~305VAC ; 127~431VDC AC input voltage range AC inrush current (max.) Cold start, 55A at 230VAC DC adjustment range ±10% rated output voltage (A-Type only) Current adjustment range HLG-80H/100H: 60%~100% ; HLG-120H: 50%~100% Over current protection 95%~108% constant current limiting, auto-recovery Over voltage protection 110%~140% rated output voltage Setup, rise, hold up time 1000ms, 80ms, 16ms at full load and 230VAC Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC Working temperature -40~+70 O C (refer to output derating curve) Safety standards UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; UL8750 listed for HLG-80H- □ BL only; Design refer to UL60950-1, EN60950-1 EMC standards EN55015, EN55022 class B (except for HLG-80H), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Connection Cold start, 60A at 230VAC 2500ms, 50ms, 16ms at full load and 230VAC Input UL rated, SJTW 18AWGx3C (30cm) Output A/D/Blank-Type: SVT 18AWGx2C (30cm) ; A/D/Blank-Type: SJTW 14AWGx2C (30cm) ; 195.6x 61.5x 38.8 220x 68x 38.8 B-Type: SVT 18AWGx2C (30cm)+UL2517 18AWGx2C (30cm) Dimension (LxWxH) (mm) B-Type: SJTW 14AWGx2C (30cm)+SJTW 18AWGx2C (30cm) Model No. HLG-80H Series Model No. HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54 (for 48V/54V) Output A A A A A A A A A 12V, 0~5.0A 15V, 0~5.0A 20V, 0~4.0A 24V, 0~3.4A 30V, 0~2.7A 36V, 0~2.3A 42V, 0~1.95A 48V, 0~1.7A 54V, 0~1.5A R&N Effi. (for 12~42BL) HLG-100H-42 A 42V, 0~2.28A ±1.0% 200mV 93% R&N Effi. HLG-100H-48 A 48V, 0~2.0A ±1.0% 200mV 93% ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV 88.0% 89.0% 90.0% 90.5% 91.0% 91.0% 91.0% 91.0% 91.0% HLG-100H-54 A 54V, 0~1.77A ±1.0% 200mV 93% (for 12~42V) (for 48/54BL) HLG-100H Series Output Tol. Tol. = A , B, BL, D or Blank Model No. Output Tol. R&N = A , B, D or Blank HLG-120H Series Model No. Output Tol. HLG-120H-12 A 12V, 0~10A ±2.5% R&N 150mV Effi. 92.0% HLG-120H-15 A 15V, 0~8.0A ±2.0% 150mV 92.0% HLG-120H-20 A 20V, 0~6.0A ±1.0% 150mV 93.0% HLG-120H-24 A 24V, 0~5.0A ±1.0% 150mV 93.0% HLG-120H-30 A 30V, 0~4.0A ±1.0% 200mV 93.0% HLG-120H-36 A 36V, 0~3.4A ±1.0% 200mV 93.0% Effi. HLG-120H-42 A 42V, 0~2.9A ±1.0% 200mV 93.0% HLG-120H-48 A 48V, 0~2.5A ±1.0% 200mV 93.5% HLG-120H-54 A 54V, 0~2.3A ±1.0% 200mV 93.5% HLG-100H-20 A 20V, 0~4.8A ±1.0% 150mV 93% HLG-100H-24 A 24V, 0~4.0A ±1.0% 150mV 93% HLG-100H-30 A 30V, 0~3.2A ±1.0% 200mV 93% HLG-100H-36 A 36V, 0~2.65A ±1.0% 200mV 93% = A , B, D or Blank HLG-120H-12A/24A/48A are our popular models. We will keep sufficient stock for prompt delivery of high quantity orders. 19 150~320W High Efficiency with PFC Features • Universal AC input (up to 305VAC) / Full range • Protections:  Short circuit / Over current / Over voltage / Over temp. • Built-in active PFC, PF>0.9 for 60% of load or higher • High efficiency up to 95% • IP67 / IP65 design for indoor or outdoor installations (except for C-Type) • Output current adjustable • Cooling by free air convection • Suitable for LED lighting and street lighting applications • Meet 4kV surge immunity level (IEC61000-4-5) • Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) C-Type: Terminal block for I/O connection (HLG-240H/320H) Blank-Type: IP67 rated. Cable for I/O connection D-Type(option): I P67 rated. Timer dimming function, contact MEAN WELL for details • Optional CQC models available (HLG-150H/185H/240H-A/Blank-Type) • 5 years warranty HLG-150H/185H HL G-2 4 0 H HL G-3 2 0 H INPUT A B C Blank/D OUTPUT (HLG-240H/320H) AC input voltage range AC inrush current (max.) DC adjustment range Current adjustment range Over current protection Over voltage protection Setup, rise, hold up time Withstand voltage Working temperature 90~305VAC; 127~431VDC Cold start, 75A at 230VAC Cold start, 70A at 230VAC ±10% rated output voltage ±6% rated output voltage HLG-150H: 60%~100% ; HLG-185H/240H/320H: 50%~100% 95%~108% constant current limiting, auto-recovery 110%~140% rated output voltage 2500ms, 80ms, 16ms 2500ms, 80ms, 15ms at full load and 230VAC I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC -40~+70 O C (refer to output derating curve) Cold start, 65A at 230VAC UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 (except for C-Type) approved; UL1012, UL60950-1, TUV EN60950-1 approved for HLG-240H only Safety standards EMC standards Input Connection Output Dimension (LxWxH)(mm) EN55015, EN55022 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 UL rated, SJTW 18AWGx3C (30cm); Terminal block for C-Type (HLG-240H/320H only) A & Blank-Type: SJTW 14AWGx2C (30cm) ; B-Type: SJTW 14AWGx2C (30cm)+SJTW 18AWGx2C (30cm); C-Type: Terminal block (HLG-240H/320H) A/B/D/Blank-Type: A/B/D/Blank-Type: 244.2x 68x 38.8 252x 90x 43.8 228x 68x 38.8 C-Type: 251x 68x 38.8 HLG-240H Series HLG-150H Series Model No. HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 HLG-150H-54 A A A A A A A A A Output Tol. R&N Effi. 12V, 0~12.5A 15V, 0~10.0A 20V, 0~7.50A 24V, 0~6.30A 30V, 0~5.00A 36V, 0~4.20A 42V, 0~3.60A 48V, 0~3.20A 54V, 0~2.80A ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV 91.5% 92.0% 93.0% 93.0% 93.5% 93.5% 94.0% 94.0% 94.0% = A , B , D or Blank Output Tol. R&N Effi. 12V, 0~13.0A 15V, 0~11.5A 20V, 0~9.30A 24V, 0~7.80A 30V, 0~6.20A 36V, 0~5.20A 42V, 0~4.40A 48V, 0~3.90A 54V, 0~3.45A ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV 91.5% 92.0% 93.0% 93.5% 93.5% 93.5% 94.0% 94.0% 94.0% = A , B , D or Blank 20 Output Tol. R&N Effi. 12V, 0~16.0A 15V, 0~15.0A 20V, 0~12.0A 24V, 0~10.0A 30V, 0~8.00A 36V, 0~6.70A 42V, 0~5.72A 48V, 0~5.00A 54V, 0~4.45A ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV 90.0% 90.0% 92.0% 93.0% 93.0% 93.0% 93.0% 93.5% 94.0% HLG-320H Series Model No. A A A A A A A A A A A A A A A A A A = A, B , C , D or Blank HLG-185H Series HLG-185H-12 HLG-185H-15 HLG-185H-20 HLG-185H-24 HLG-185H-30 HLG-185H-36 HLG-185H-42 HLG-185H-48 HLG-185H-54 Model No. HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42 HLG-240H-48 HLG-240H-54 Model No. HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 HLG-320H-54 A A A A A A A A A Output Tol. R&N Effi. 12V, 0~22.0A 15V, 0~19.0A 20V, 0~15.0A 24V, 0~13.34A 30V, 0~10.7A 36V, 0~8.90A 42V, 0~7.65A 48V, 0~6.70A 54V, 0~5.95A ±3.0% ±2.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV 91.0% 92.5% 93.5% 94.0% 94.0% 94.5% 95.0% 95.0% 95.0% = A , B , C , D or Blank HLG-185H-12A/24A/48A & HLG-240H-12A/24A/48A are our popular models. We will keep sufficient stock for prompt delivery of high quantity orders. 70~ 200 W Co nst ant Cu rrent w i t h PF C Features •2Constant current output with high output voltage>60VDC • Suitable for LED lighting and street lighting applications •2Universal AC input (up to 305VAC)/ Full range •2Multiple models for choice: •2Built-in active PFC function A-Type: IP65 rated. Constant current level can be adjusted •2High efficiency up to 94% through internal potentiometer •2Protections: Short circuit / Over voltage / Over temperature B-Type: IP67 rated and built-in 3 in 1 dimming function •2Cooling by free air convection (1~10VDC, PWM signal, or resistance) •2Output current adjustable through output cable or internal D-Type (option): IP67 rated. Timer dimming function, potentiometer contact MEAN WELL for details •2IP67 / IP65 design for indoor or outdoor installations •25 years warranty • Suitable for dry, damp, and wet location HLG-60H-C HLG-80H-C NE W INPUT HLG-120H-C NE W HLG-185H-C De U ve nd lop er me nt De U ve nd lop er me nt OUTPUT AC input voltage range 90~305VAC; 127VDC~431VDC AC inrush current (Typ.) Cold start, 60A at 230VAC Cold start, 70A at 230VAC Current adjustment range 60%~100% 50%~100% Short circuit protection Hiccup mode, auto-recovery Over temp. protection 85 O C±10 O C(RTH2), shut down o/p voltage, re-power on to recover Withstand voltage I/P-O/P:3.75kVAC, I/P-FG:2kVAC, O/P-FG:0.5kVAC Working temperature -40~+70 O C (refer to output derating curve) Safety standards UL8750, TUV EN61347-1, EN61347-2-13 approved (HLG-120H-C/185H-C pending) EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Connection Input UL rated, SJTW 16AWGx3C(30cm) Output A&D-Type: SJTW 16AWGx2C(30cm) B-Type: SJTW 16AWGx2C(30cm)+ SJTW 16AWGx2C(30cm) A&D-Type: STW 16AWGx2C(30cm) B-Type: STW 16AWGx2C(30cm)+ SJTW16AWGx2C(30cm) 171x 61.5x 36.8 220x 68x 38.8 Dimension (LxWxH)(mm) 195.6x 61.5x 38.8 HLG-80H-C Series HLG-60H-C Series Mod e l N o . O ut p ut I o Tol . R& N E ffi. HLG-60H-C350 A 100~200V, 350mA ±5% 1.0V 91.0% HLG-60H-C700 A 50~100V, 700mA ±5% 0.5V 90.5% Ou tpu t Io Tol. R&N E f f i. HLG-80H-C350 A 167~257V, 350mA ±5% 1.0V 91.5% HLG-80H-C700 A 84~129V, 700mA ±5% 0.5V 91.5% Model No. = A, B or D = A, B or D HLG-120H-C Series UL/CUL/TUV/CB/CE pending O ut p ut I o Tol . R& N E ffi. HLG-120H-C350 A 215~430V, 350mA ±5% 1.0V 93.5% HLG-120H-C500 A 150~300V, 500mA ±5% 1.0V 93.5% HLG-120H-C700 A 107~215V, 700mA Mod e l N o . 228x 68x 38.8 HLG-185H-C Series UL/CUL/TUV/CB/CE pending Ou tpu t I o Tol. R&N E f f i. HLG-185H-C500 A 200~400V, 500mA ±5% 1.0V 94% HLG-185H-C700 A 143~286V, 700mA ±5% 0.5V 94% Model No. ±5% 0.5V 93.5% HLG-185H-C1050 A 95~190V, 1050mA ±5% 0.5V 94% HLG-120H-C1050 A 74~148V, 1050mA ±5% 0.5V 93.5% HLG-185H-C1400 A 71~143V, 1400mA ±5% 0.5V 94% HLG-120H-C1400 A 54~108V, 1400mA ±5% 0.5V 93.5% = A, B or D = A, B or D 21 96~150W Wide Input Range with PFC Features •2Wide input range: 180~480VAC for HVG(C)-100 180~528VAC for HVG(C)-150 • Protections: Short circuit / Over voltage / Over temperature / Over current (HVG-100/150) • Built-in active PFC • High efficiency up to 91.5% • IP67 / IP65 design • Cooling by free air convection • C.V. +C.C. mode design (HVG-100/150) • Constant current design (HVGC-100/150) • Output current adjustable through output cable or internal potentiometer • Class 2 power unit / Pass LPS for HVG-100 • Suitable for dry, damp, and wet location • Suitable for LED lighting and street lighting applications • Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (0~10VDC, PWM signal, or resistance) D-Type (option): IP67 rated. Timer dimming function, contact MEAN WELL for details • 5 years warranty HVG/HVGC-100 HVG/HVGC-150 NE W INPUT OUTPUT AC input voltage range AC inrush current (max.) DC adjustment range Current adjustment range Over current protection ( HVG-100/150 ) Over voltage protection Withstand voltage Working temperature Safety standards EMC standards Input Connection A&DType Output BType Dimension (LxWxH)(mm) HVG-100 Series 180~480VAC(single phase); 254~679VDC 180~528VAC (single phase); 254~747VDC Cold start, 25A at 440VAC Cold start, 35A at 480VAC ±10% rated output voltage HVG-100/150: 55%~100% ; HVGC-100/150: 60%~100% 95%~108% constant current limiting, auto-recovery 110%~140% rated output voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC -40~+70 OC (refer to output derating curve) HVG-100/150: UL8750 approved HVGC-100/150: UL8750, TUV EN61347-1, EN61347-2-13 approved EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, FCC part 15 class B UL rated, STW 18AWGx3C (30cm) HVG-100: SVT 18AWGx2C (30cm) HVG-150: SJTW 14AWGx2C (30cm) HVGC-150: STW 18AWGx2C (30cm) HVGC-100: SJTW 18AWGx2C (30cm) HVG-100: SVT 18AWGx2C (30cm)+ UL2517 18AWGx2C (30cm) HVGC-100: SJTW 18AWGx2C(30cm)+ UL2517 18AWGx2C (30cm) 236x 68x 38.8 (C.V. +C.C. mode) (for 42~54V) (for 15~36V) Model No. Output Tol. R&N Effi. HVG-100-15 A 15V, 0~5.0A ±2.0% 150mV 89.0% HVG-100-20 A 20V, 0~4.8A ±1.0% 150mV 90.0% HVG-100-24 A 24V, 0~4.0A ±1.0% 150mV 91.0% HVG-100-30 A 30V, 0~3.2A ±1.0% 200mV 91.0% HVG-100-36 A 36V, 0~2.65A ±1.0% 200mV 90.5% HVG-100-42 A 42V, 0~2.28A ±1.0% 200mV 90.5% HVG-100-48 A 48V, 0~2.0A ±1.0% 200mV 91.0% HVG-100-54 A 54V, 0~1.77A ±1.0% 200mV 91.0% = A , B or D HVGC-100 Series Model No. 22 HVG-150 Series (C.V. +C.C. mode) Model No. HVG-150-12 HVG-150-15 HVG-150-20 HVG-150-24 HVG-150-30 HVG-150-36 HVG-150-42 HVG-150-48 HVG-150-54 Output A A A A A A A A A 12V, 15V, 20V, 24V, 30V, 36V, 42V, 48V, 54V, 0~10A 0~10A 0~7.5A 0~6.25A 0~5A 0~4.17A 0~3.58A 0~3.13A 0~2.78A Tol. R&N Effi. ±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% 150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV 87.0% 89.0% 90.5% 91.0% 91.0% 91.0% 91.0% 91.5% 91.5% = A , B or D HVGC-150 Series (C.C. mode) Output Io Tol. R&N (C.C. mode) Effi. Model No. Output Io Tol. R&N Effi. HVGC-150-350 A HVGC-150-500 A HVGC-150-700 A HVGC-150-1050 A HVGC-150-1400 A 42~428V, 350mA 30~300V, 500mA 21~215V, 700mA 15~143V, 1050mA 12~107V, 1400mA ±5% ±5% ±5% ±5% ±5% 2.0V 1.5V 1.0V 0.7V 0.5V 91% 91% 91% 90% 90% HVGC-100-350 A 29~285V, 350mA ±5% 1V 91% HVGC-100-700 A 15~142V, 700mA ±5% 0.5V 91% = A , B or D HVG-150: S  JTW 14AWGx2C (30cm)+ UL2517 18AWGx2C (30cm) HVGC-150: S TW 18AWGx2C (30cm)+ UL2517 18AWGx2C (30cm) 245x 68x 38.8 = A , B or D 70W &150W Single Output with PFC / Surge Protection Device 7 0 W R e c t a n gu l a r Met a l C a se 1 5 0 W U-Brac ket Single Out put w ith PFC •Universal AC input (up to 305VAC) • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC • Output current adjustable through internal potentiometer • IP65 design • Cooling by free air convection • Suitable for LED lighting and moving sign applications • 3 years warranty 127.2x 90x 38.8 mm •Universal AC input (up to 295VAC) •Built-in active PFC function •High efficiency up to 93% • P rotections: S hort circuit / Overload / Over voltage / Over temperature •Constant voltage design •Cooling by free air convection •U-bracket low profile: 33mm •3 years warranty 215x 67.4x 33 mm AC input voltage range AC inrush current (max.) 90~295VAC; 127~417VDC Cold start, 65A at 230VAC Current adjustment range 60%~100% Overload protection Over current protection 95%~108% constant current limiting 130%~185% hiccup mode, auto-recovery Over voltage protection 112%~140% rated output voltage Over voltage protection 110%~135% rated output voltage Setup, rise, hold up time Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 1.88kVAC, O/P-FG: 0.5kVAC 2000ms, 100ms, 16ms at full load and 230VAC Working temperature -40~+70OC (refer to output derating curve) Withstand voltage I/P-O/P: 3.75kVAC, I/P-FG: 1.88kVAC, O/P-FG: 0.5kVAC Safety standards Design refer to EN61347-1, EN61347-2-13 Working temperature EMC standards EN55015, EN61000-3-2 class C, EN61000-3-3, EN61547, EN61000-4-2,3,4,5,6,8,11 O -30~+70 C (refer to output derating curve) Safety standards Design refer to UL8750, EN61347-1, EN61347-2-13 Input H05RN-F 1.5mm2x2C (30cm) EMC standards Output H05RN-F 1.0mm2x3C (30cm) EN55015, EN61000-3-2 class C, EN61000-3-3, EN61547, EN61000-4-2,3,4,5,6,8,11 AC input voltage range Connection 90~305VAC; 127~431VDC Model No. Output Tol. R&N Effi. Model No. Output Tol. R&N Effi. HSG-70-12 12V, 0~5.0A ±2.5% 150mV 88% ULP-150-12 12V, 0~12.5A ±2% 100mV 91.5% HSG-70-18 18V, 0~4.0A ±2.0% 200mV 89% ULP-150-15 15V, 0~10.0A ±2% 150mV 91.5% HSG-70-24 24V, 0~3.0A ±1.0% 200mV 89% ULP-150-24 24V, 0~6.30A ±2% 150mV 93.0% HSG-70-36 36V, 0~2.0A ±1.0% 200mV 90% ULP-150-36 36V, 0~4.20A ±2% 250mV 93.0% HSG-70-48 48V, 0~1.5A ±1.0% 200mV 90% ULP-150-48 48V, 0~3.20A ±2% 250mV 93.0% 2 0 k A S u rge Pro t ec t io n D ev ic e Features •U L1449 3rd Edition, Type 2 component assemblies •L ine to Ground & Line to Line protected •P arallel (3 wires) connection style •LED status indicators 90x 70x 50 mm •IP67 design •Suitable for surge protection of LED drivers (SPD-20-240P) Model No. SPD-20-240P SPD-20-277P Operating voltage 240VAC, 50/60Hz 277VAC, 50/60Hz MCOV (Max. Continuous Operating Voltage) 300VAC 320VAC VPR (Voltage Protection Rating) ≤1200 (L-FG, N-FG, L-N) IN (Nominal Discharge Current) 5kA Max. Surge Current (8/20μs) 20kA SCCR (Short Circuit Current Rating) 5kA Response time <25ns Operating temperature -40~+70OC Safety standard UL1449 3rd Edition, TUV EN61643-11 approved UL1449 3rd Edition approved L (Black) Connection N (White) FEP 10AWG (15cm) FG (Green) 23 DC-DC Co nst ant Cu rrent LED Dr i ve r Features •Constant current LED driver •W ide input and output voltage range •High efficiency up to 97% •C omply with EN55015 and FCC part 15 without additional input filter and capacitors •Built-in PWM dimming and remote ON/OFF control •P rotections: Short circuit / Over temperature •Compact size •O perating temperature range: -40~+85 o C •Cooling by free air convection •Fully enclosed plastic case (UL 94V-0) •Low cost, high reliability •3 years warranty LDD - H / HW / HS L D D -L / LW / L S NEW ±3% at 24VDC input; ±4% at 48VDC input for LDD-H/HW; ±5% at 48VDC input for LDD-HS Output Current Accuracy NEW ±5% at 24VDC input Leave open if not used PWM Dimming & ON/OFF Control Remote ON/OFF Power ON with dimming: DIM~-Vin>2.5~6VDC or open circuit Power OFF: DIM~-Vin <0.8VDC or short PWM Frequency 100~1KHz Regulated at rated output current, can be continued, auto-recovery Tj 150o C typically detect on main control IC Shut down, recovers automatically after temperature goes down - 4 0 ~ + 8 5 o C (refer to output derating curve) EN55015, FCC part 15 class B, EN61000-4-2,3,4,6,8, light industry level, criteria A 100o C LDD-H/HW: 31.8x 20.3x 12.2 LDD-L/LW: 22.6x 9.9x 8.9 LDD-HS: 31.8x 20.3x 11.4 LDD-LS: 25.4x 10.5x 9.3 Short circuit Range Type Working temperature EMC standards Operating case temp. (max.) Over temp. protection Dimension (LxWxH)(mm) LDD-H Series Model No. LDD-L Series Input LDD-300H LDD-350H LDD-500H LDD-600H LDD-700H LDD-1000H Output (VDC) Voltage 9~56 9~56 9~56 9~56 9~56 9~56 2~52 2~52 2~52 2~52 2~52 2~52 (VDC) Current Io Tol. Effi. Input LDD-300HW LDD-350HW LDD-500HW LDD-600HW LDD-700HW LDD-1000HW 300 350 500 600 700 1000 ±4% ±4% ±4% ±4% ±4% ±4% 97% 97% 97% 97% 97% 97% 24 LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L Input Output (VDC) Voltage Current Io Tol. Effi. 9~36 9~36 9~36 9~36 9~36 2~32 2~32 2~32 2~32 2~32 300 350 500 600 700 ±5% ±5% ±5% ±5% ±5% 95% 95% 95% 95% 95% (VDC) (mA) LDD-LW Series Output (VDC) Voltage Current Io Tol. 9~56 9~56 9~56 9~56 9~56 9~56 2~52 2~52 2~52 2~52 2~52 2~52 300 350 500 600 700 1000 ±4% ±4% ±4% ±4% ±4% ±4% (VDC) Effi. Input 97% 97% 97% 97% 97% 97% Output (VDC) Voltage Current Io Tol. Effi. LDD-300LW 9~36 2~32 300 ±5% 95% LDD-350LW 9~36 2~32 350 ±5% 95% LDD-500LW 9~36 2~32 500 ±5% 95% LDD-600LW 9~36 2~32 600 ±5% 95% LDD-700LW 9~36 2~32 700 ±5% 95% Current Io Tol. Effi. 300 350 500 600 700 style ±5% ±5% ±5% ±5% ±5% 95% 95% 95% 95% 95% Model No. (mA) (VDC) (mA) LDD-LS Series LDD-HS Series Model No. Model No. (mA) LDD-HW Series Model No. Power ON with dimming: DIM~-Vin>3.5~8VDC or open circuit Power OFF: DIM~-Vin <0.5VDC or short Input (VDC) Output Voltage (VDC) Current Io Tol. Effi. (mA) LDD-300HS 9~56 2~52 300 LDD-350HS 9~56 2~52 350 LDD-500HS 9~56 2~52 500 LDD-600HS 9~56 2~52 600 LDD-700HS 9~56 2~52 700 LDD-1000HS 9~56 2~52 1000 H: pin style, HW: wire style, HS: SMD style ±5% ±5% ±5% ±5% ±5% ±5% 96% 96% 96% 96% 96% 96% Model No. Input (VDC) Output Voltage (VDC) LDD-300LS 9~36 2~32 LDD-350LS 9~36 2~32 LDD-500LS 9~36 2~32 LDD-600LS 9~36 2~32 LDD-700LS 9~36 2~32 L: pin style, LW: wire style, LS: SMD (mA) 96~240W Circular Shape for High Bay Lighting Description HBG series are high performance LED power supplies specially designed for the high/low bay lighting and spot lighting applications. Featuring with circular shape, these new series are easy to be assembled and perfectly fit in with the mechanical structure of high/ low bay lighting fixtures. Fully potted by glue, their aluminum enclosure can be tightly assembled to the heat sink of lighting fixtures and provide excellent heat dissipation ability, which solve the mechanism limits of old style bay lighting systems using slim shape LED power supplies. As long as the temperature on the top of the enclosure can be controlled under 70 o C, the power supply service life could be guaranteed up to 40,000 hours. For more detail information, please visit our website: www.meanwell.com/product/HBG/HBG.html H B G- 10 0 HBG-1 6 0 HBG-2 4 0 NE W NE W DxH: 130x 66.5mm De U ve nd lop er me nt DxH: 151.68x 66.5mm DxH: 191.5x 69mm Features •Universal AC input (90~305VAC) •Built-in active PFC function •High efficiency up to 93.5% •Protections: Short circuit / Over current / Over voltage / Over temperature •Output current adjustable through internal potentiometer •IP67 / IP65 design for indoor or outdoor installations •Suitable for dry, damp, and wet location HBG-100 Series UL/CUL/TUV/CB/CE pending Model No. Output HBG-100-24 A 24V, HBG-100-36 A 36V, HBG-100-48 A 48V, HBG-100-60 A 60V, = A, B, E or Blank Tol. 0~4.0A 0~2.7A 0~2.0A 0~1.6A HBG-160 Series Model No. Effi. ±1% ±1% ±1% ±1% HBG-240 Series UL/CUL/TUV/CB/CE pending Output Tol. Effi. HBG-160-24 A HBG-160-36 A 24V, 0~6.5A 36V, 0~4.4A ±1% ±1% 92.0% 92.0% ► ►Construction of High Bay Light HBG Series + Heat Sink + Light Source + Output HBG-160-48 A 48V, 0~3.3A HBG-160-60 A 60V, 0~2.6A = A, B, E or Blank 90.5% 91.0% 91.0% 91.5% Model No. Ring •Multiple models for choice: A-Type: IP65 rated. Constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection E-Type(option): IP67 rated. Can be mounted on metal frame, contact MEAN WELL for details •5 years warranty Tol. Effi. ±1% ±1% 93.0% 93.5% UL/CUL/TUV/CB/CE pending Model No. HBG-240-24 A HBG-240-36 A HBG-240-48 A HBG-240-60 A = A, B or Blank Output Tol. Effi. 24V, 0~10A 36V, 0~6.7A 48V, 0~5.0A 60V, 0~4.0A ±1% ±1% ±1% ±1% 92.5% 92.5% 93.0% 93.5% lampshade High Bay Light + ► ►Installations Spot Light Stage Light High Bay Light Chain Type Hanger Type 25 ► ►Female Waterproof Output Connector (Power supply side) P i n C o n f i g u r a t i o n (F e m a l e ) Waterproof Connector M12 M15 Order No. : M12-02 Order No. : M12-04 Suitable Current : 5A max. 2-pin (5A/PIN) Suitable Current : 10A max. 4-pin (5A/PIN) M 2 0 .5 Order No. : M15-02 2-pin (12A/PIN) Suitable Current : 12A max. 2-pin (20A/PIN) M 2 0 .8 Order No. : M20.5-02 Order No. : M20.8-02 Suitable Current : 20A max. Suitable Current : 20A max. ► The output cable can be modified to include different waterproof connectors by MEAN WELL. Minimum order quantity may vary for different models. ► We would suggest you to order the configurations of "M15 connector with length of 20cm / 30cm / 45cm / 60cm / 80cm / 100cm cables" due to its cost effectiveness and fast delivery. Ordering other connector type or cable lengths will have higher cost and longer lead-time. ► Suitable for CLG / HLG / HLG-C / HVG(C) / CEN / HSG / HLN / LPF series. ► ►Male Waterproof Output Connector with Cable (System side) Figure Drawing L= 30cm / 60cm / 100cm for choice ► M EAN WELL offers male waterproof connectors with cable length of 30cm, 60cm, and 100cm as our standard mating accessories. These mating accessories need to be ordered together with PSU. For other length or cable style, the higher MOQ requirement and long lead-time will be expected. Please consult MEAN WELL for details. ► ►Order No. M12-02M-30-U1-UN 1 2 3 4 5 Cable Type 3 6 Connector Type: Male / Female 1 M12 UN & CH M15 UN & CH M20.5 UN only 2P 2pin 4P 4pin F Female (PSU Side) 5 4 30 30cm 60 60cm 100 100cm 6 Cable Length: Female with Cable 20 20cm M15, M20.5 and M20.8 only have 2-pin choice 30 30cm 45 45cm 60 60cm 80 80cm U1 SJTW (USA) E1 H05RN-F (EURO) Brand Name Cable Length: Male with Cable M20.8 CH only No. of PIN 2 M Male (System Side) UN UNICABLE (Made in Taiwan) CH CHOGORI (Made in China) 100 100cm ►►Waterproof Cable Joiner 66 20 φ25 26 CJ04-1 suitable for 14AWG~16AWG CJ04-2 suitable for 18AWG~22AWG Order No. : CJ04-1  CJ04-2 Up to four wires can be connected through this cable joiner by soldering or clamping by tools. ► CJ04 cable joiner can be purchased independently for user's own assembly. 26 • Decide a suitable wattage level, including safety margin. • Verify your design of LED driving circuit: direct drive by PSU [choose a constant current (C.C.) mode LED power supply] or add additional driving IC to get a more precise constant current level [choose LDD]. • Verify whether the application need PFC function. • Verify location of assembly and the required level against dust and humidity for the LED power supply (enclosure style, IP level, dry/damp/wet location). • Verify the required safety certificates. • Need to adjust the output voltage and/or output current or need the dimming function ? ► ►Su gg e s t e d S y s t e m D e s ig n Setting Circuit Diagram Description Advantage & Disadvantage Use constant Using MEAN WELL's C.C. mode LED Advantage current (C.C.) power supply as constant current • Simplest design, no need LED +V(Red) mode power supply only AC/DC C.C. mode PSU -V(Black) source and feed the LED arrays directly. 0.35A ... ... 0.35A ... ... driver IC • Lower price • Higher efficiency with the MEAN WELL product: best lumen per watt(lm/w) ... ... ... ... APC / LPC / ELN / PLN / PLC / LPF / 0.35A HLN / PLD / PLM / CLG / CEN / HLG Disadvantage / HLG-C / HSG / HVG / HVGC / HBG • Unbalanced driving current / PLP / HLP / LCM families ... ... and shorter LED life time • LED chips should be sorted for similar VF Use constant voltage (C.V.) mode power +V (Red) AC/DC C.V. mode LED PSU - V (Black) Using AC/DC C.V. mode LED power Advantage supply and separate DC/DC LED • Independent output drivers. current for paralleled LED supply with +V Driver IC -V strips ... • No need to sort the VF of LED -V • Longer LED lifetime 0.35A +V Driver IC ...... driver 0.35A +V ... ... DC-DC LED channels, the most balanced Driver IC • Failures in any string do not ... affect the other strings -V MEAN WELL product: 0.35A +V ... -V DC/DC LED Driver Any AC/DC LED power supply+ LDD series (DC/DC LED driver) Disadvantage • Higher price • Complicated circuit design • Lower system efficiency • L arger in power supply volume 27 Note At the moment of power on, the LED power supply will work in C.V. mode and can provide a peak output current; after the LED turns on, the LED power supply will go into C.C. mode (patent pending). Metal Case NE W NE W PFC Plastic Case Constant Voltage + Constant Current (C.V.+C.C.) Note PCB Type Non-PFC Constant Current PFC Plastic Case Plastic Case (C.C.) NE W PFC U-bracket Metal Case Constant Voltage (C.V.) Non-PFC 28 NE W Plastic Case Series CEN-60/75 CEN-100 Dimension (Lx Wx H) 185x 62.5x 40.5 mm 195x 62.5x 40.5 mm Page Series CLG-60 CLG-100 CLG-150 Dimension (Lx Wx H) 195.6x 61.5x 38.8 mm 222.2x 68x 38.8 mm 229x 68x 38.8 mm Page Series HLG-40H/60H/60H-C HLG-80H/80H-C HLG-100H/120H/120H-C HLG-150H/185H/185H-C HLG-240H HLG-320H Dimension (Lx Wx H) 171x 61.5x 36.8 mm 195.6x 61.5x 38.8 mm 220x 68x 38.8 mm 228x 68x 38.8 mm 251x 68x 38.8 mm 252x 90x 43.8 mm Page 18/21 19/21 19/21 20/21 20 20 Series HVG(C)-100 HVG(C)-150 Dimension (Lx Wx H) 236x 68x 38.8 mm 245x 68x 38.8 mm Page Series HSG-70 Dimension (Lx Wx H) 127.2x 90x 38.8 mm Page 23 Series HBG-100 HBG-160 HBG-240 Dimension (Dx H) 130x 66.5 151.68x 66.5 191.5x 69 Page Series LPF-16(D)/25(D) LPF-40(D)/60(D) LPF-90(D) Series PLC-30 PLC-45/60 PLC-100 Dimension (Lx Wx H) 148x 40x 32 mm 162.5x 43x 32 mm 161x 61x 36 mm Dimension (Lx Wx H) 160x 46x 30 mm 181.5x 62x 35 mm 200.5x 69.5x 35 mm Page Series PLN-20 PLN-30 PLN-45/60 PLN-100 Dimension (Lx Wx H) 148.5x 38.5x 28 mm 145x 47x 30 mm 181x 61.5x 35 mm 200x 70.5x 35 mm Page Series HLN-40H/60H HLN-80H Dimension (Lx Wx H) 161x 61.5x 35 mm 181x 61.5x 35 mm Page Series PLP-20 PLP-30 PLP-45/60 Dimension (Lx Wx H) 140x 32x 22 mm 101.6x 50.8x 26.6 mm 101.6x 50.8x 29.6 mm Page Series HLP-40H/60H HLP-80H Dimension (Lx Wx H) 147x 53x 27 mm 167x 53x 29.5 mm Page Series APC-12/16 APC-25/35 Series LPLC-18, LPHC-18 LPC-20 LPC-35 LPC-60 Dimension (Lx Wx H) 77x 40x 29 mm 84x 57x 29.5 mm Dimension (Lx Wx H) 140x 30x 22 mm 118x 35x 26 mm 148x 40x 30 mm 162.5x 42.5x 32 mm Page Series ELN-30 ELN-60 Dimension (Lx Wx H) 145x 47x 30 mm 181x 61.5x 35 mm Page Series PCD-16/25 PCD-40/60 PLD-16/25 PLD-40/60 Dimension (Lx Wx H) 84x 57x 29.5 mm 128x 60x 31.5 mm 84x 57x 29.5 mm 128x 60x 31.5 mm Page Series PLM-12/25 PLM-40 Dimension (Lx Wx H) 145x 38x 22 mm 175x 42x 24 mm Page Series LCM-40(DA)/60(DA) Dimension (Lx Wx H) 123.5x 81.5x 23 mm Page 13 Page 16 17 22 25 9 Page 10 11 12 14 15 2 Page 4 5 6 7 8 Series Dimension (Lx Wx H) ULP-150 215x 67.4x 33 mm Series APV-12/16 APV-25/35 Dimension (Lx Wx H) 77x 40x 29 mm 84x 57x 29.5 mm Page Series LPL-18, LPH-18 LPV-20 LPV-35 LPV-60 LPV-100 Dimension (Lx Wx H) 140x 30x 22 mm 118x 35x 26 mm 148x 40x 30 mm 162.5x 42.5x 32 mm 190x 52x 37 mm Page 23 2 3 Family Type Series Name HLG-40H / 60H / 80H / 100H / 120H / 150H / 185H / 240H / 320H PFC (Note 1) (Note 3) A B C (240W/320W only) Blank Two Stage AC Input Range (VAC) Potted 90~305 C.C. or C.V. C.V.+C.C. D (option) A HLG-60H-C/ 80H-C/ 120H-C/ B D (option) 185H-C A B HBGBlank 100/160/240 E (option, 100W/160W only) A HVG(C)-100/150 B D (option) HSG-70 CLG-150 Single Stage A B C Blank 90~305 C.V.+C.C. 90~305 C.V.+C.C. IP 65 67 67 Dimming Vo / Io Max. (Note 2) Adj Eff. 3 in 1 67 Timer 67 65 67 67 Timer 65 67 3 in 1 3 in 1 Warranty (years) Remark 95% 5 Vo<60VDC 94% 5 Vo>60VDC 93.5% 5 Circular shape 91.5% 5 90% 3 91% 3 67 180~480 (528) C.V.+C.C. 65 67 67 90~305 C.V.+C.C. 65 90~295 C.V.+C.C. 3 in 1 Timer Io 65 67 Resistance 67 CLG-100 90~295 C.V.+C.C. 67 88.5% 3 CLG-60 90~295 C.V.+C.C. 67 89% 3 CEN-60 / 75 / 100 90~295 C.V.+C.C. 66 91% 3 ULP-150 90~295 93% 3 91% 3 90.5% 3 A HLN-40H / 60H / 80H B LPF-16 / 25 / 40 / 60 / 90 Blank D (half) C.V. Vo 90~305 C.V.+C.C. 64 90~305 C.V.+C.C. (16W option) 67 3 in 1 3 in 1 PLN-100 90~295 C.V.+C.C. 64 88.5% 2 PLN-30 / 45 / 60 90~295 C.V.+C.C. 64 89% 2 PLN-20 90~277 C.V.+C.C. 64 83.5% 2 PLC-100 90~264 C.V.+C.C. 90% 2 PLC-30 / 45 / 60 90~264 C.V.+C.C. 89% 2 87% 3 88% 3 88% 2 PCD-16 / 25 / 40 / 60 PLD-16 / 25 / 40 / 60 A: 90~135 B: 180~295 16/40/60W: A-90~135 B-180~295 25W: 90~295 PLM-12/25/40 LCM-40 / 60 LCM-40DA / 60DA PLP-20 / 30 / 45 / 60 HLP-40H / 60H / 80H ELN-30 / 60 LPH / LPL-18 LPV-20 / 35 / 60 / 100 LPHC / LPLC-18 LPC-20 / 35 / 60 APC-12 / 16 / 25 / 35 (half) (half) 90~295 180~295 30 C.C. 30 C.C. 30 C.C. 20W: 90~277 30~60W:90~264 90~305 20 AC Phase-Cut 0~10Vdc & PWM 92% DALI & push DIM 91.5% C.V.+C.C. 90~264 LPH: 180~264 LPL: 90~132 LPV: 90~264 LPHC: 180~264 LPLC: 90~132 LPC: 90~264 90~264 C.C. Io (16W/35W half) Io U-bracket Terminal block I/O Terminal block I/O 3 Io level selectable in one power unit 89% 2 PCB type PCB type C.V.+C.C. 3 in 1 90.5% 3 C.V.+C.C. 64 1~10Vdc or PWM 88% 2 C.V. 67 89% 2 C.V.+C.C. 67 87% 2 C.V.+C.C. 30 84% 2 90~264 C.V. 30 85% 2 (16W/35W half) Note 1 •S ingle-Stage PFC : No hold-up time and higher Ripple & Noise. Not to use in regions with unstable utility status is highly recommended. (For C.V. mode operation, please refer to the application Q&A on MEANWELL LED website.) • Two-Stage PFC : Longer hold-up time and lower Ripple & Noise. Suitable for LED lighting and general industrial applications. • Non-PFC : PF<0.6 and target at regions where PF compliance does not required. Note 2 3-in-1 dimming: 1~10Vdc, PWM signal, or resistance. Timer: Timmer dimming function, please contact MEANWELL for details. are popular models and will have sufficient stock for prompt delivery of high quantity orders. Note 3 APV-12 / 16 / 25 / 35 29 Ta iw an 明緯企業股份有限公司 MEAN W ELL ENTE R PR I SE S C O. , LTD. 248 9 1 新北市五股 區 五 權 三 路 2 8 號 No. 2 8 , W uqua n 3rd Rd., W u g u Dis t ., New Ta ipei C ity 2 4 8 9 1 , Ta iwa n ( R.O.C.) 統一編號:3 4 4 9 1 0 7 5 Te l :+8 8 6 - 2- 22 9 9 -6 1 0 0 ( rep.) Fa x :+88 6 - 2- 22 9 9 -6 2 0 0 ( rep.) +88 6 - 2- 22 9 8 -0 8 1 8 ( s a l es ) E-ma il:inf o@mea n wel l .c o m h t tp ://www. mea nwel l .c o m C h ina U .S.A . 明緯(廣州)電子有限公司 MEA N WEL L U S A , I N C. MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD. 廣州市天河區東圃鎮黃 村 大 道 粵 安 工 業 園 A棟 2 樓 2nd Floor, No.A Bu il din g , Yu ea n In d. Pa rk , D ongp u Town, Tian h e Dis t ric t , G u a n g zh o u , Ch i na Post C ode: 51 0 6 6 0 Te l :+8 6 - 20 - 28 8 7 -1 2 0 0 4 0 0 -0 2 0 -1 2 0 0 ( 免 付 費 電 話 ) Fa x :+86 - 20 - 82 0 1 -0 5 0 7 E-ma il:inf o@mea n wel l .c o m.c n h t tp ://www. mea nwel l .c o m.c n 4 4 0 3 0 Fr e m ont B l v d . , Fr e m ont , C A 9 4 5 3 8 , U. S . A . Te l : + 1 - 5 1 0 - 6 8 3 - 8 8 8 6 Fa x : + 1 - 5 1 0 - 6 8 3 - 8 8 9 9 E- m a i l : i nfo@ m e a nw e l l usa . c om ht t p : / / w w w. m e a nw e l l usa . c om 蘇州明緯科技有限公司 S UZHOU MEAN WE L L TE C H N OLOGY C O. , LTD. 江蘇省蘇州市相城區黃 埭 鎮 潘 陽 工 業 園 東 橋 健 民 路 7 7號 No. 7 7 , Jia n- Ming Rd. Do n g -Q ia o , Pan-Ya ng Ind. Pa r k , H u a n g -Da i To wn , Xiang- C heng Distric t , Su zh o u , J ia n g -Su , Ch in a Post C ode: 21 5 1 5 2 Te l :+8 6 - 51 2 - 65 0 8 -8 6 0 0 Fa x :+86 - 51 2 - 65 0 8 -8 7 0 0 E-ma il:inf o@mea n wel l .c c h t tp ://www. mea nwel l .c c E u rope MEA N WEL L EU R OP E B. V. L a ng s d e We r f 8 , 1 1 8 5 X T A m st e l v e e n, T he N e t he r l a nd s Te l : + 3 1 - 2 0 - 7 5 8 - 6 0 0 0 Fa x : + 3 1 - 2 0 - 7 5 8 - 6 0 0 1 E- m a i l : i nfo@ m e a nw e l l . e u ht t p : / / w w w. m e a nw e l l . e u Ple ase C on ta ct Yo ur Lo ca l Di st r ib ut o r www.meanwell.com This catalog is printed with soy ink