Since 2006, we star ted to endeavor the development of waterproof LED power supplies. Thus far, more than 1000 models comply with specif ic lighting norms per UL8750, UL1310, UL879, EN61347-2-13, IEC61347-2-13(CB), and EN61000-3-2 Class C (harmonic current) have been launched in the market with utmost success. In this catalog, we are glad to introduce you dif ferent t ypes of LED power supplies, which are ver y suitable for LED street lighting, LED tunnel lighting, outdoor electronic display, of f ice lighting, LED decorative lighting, LED architectural lighting …etc. all kinds of outdoor or indoor LED lighting related applications. If they still can’t meet your requirement, ME AN WELL also of fers over 4,000 standard industrial switching power supplies from 5W to 3,000W for your selection. Please visit our website for more details —
w w w.meanwell.com
Featured New Products LCM-40(DA)/60(DA) Series
Page 13
40W/ 60W multiple-stage output current supporting DALI interface
HLG-C Series
HVG(C)-150 Series
Page 22
150W wide input range (180~528VAC) with PFC function
Page 21
70W/ 90W/ 150W/ 200W Constant current output with high output voltage >60VDC
HBG Series
100W/ 160W/ 240W Circular Shape for High Bay Lighting
Page 25
Index 2
AP series
12~35W
16
LP series
18~100W
17
• Economical with Slim Plastic Case • IP67
5
ELN series PCD series
18~20 30~60W
7
PLD series PLM series
40~320W
• IP65 & IP67 • 5 Years Warranty
21
HLG-C series
70~200W
• C.C. Output with High Output Voltage>60VDC • PFC Function • Metal Case
16~60W
12~40W
HLG series
• Metal Case • 3 in 1 Dimming Function
• 3 in 1 Dimming Function
• PFC Function • Plastic Case
8
60~150W
• High Efficiency with PFC Function
16~60W
• PFC Function • Plastic Case • AC Phase-cut Dimming
CLG series
• PFC Function • Metal Case • IP65 & IP67
• Dimming Option • Plastic Case
6
60~96W
• PFC Function • Metal Case • IP66
• Low Cost with Rectangular Plastic Case
3~4
CEN series
• IP65 & IP67 • 5 years warranty
22
HVG(C) series
96~150W
• PFC Function • Metal Case • IP65 & 67
• PFC Function • Economical with Plastic Case • Push Terminal I/O
• Wide Input Range: 180~480VAC/100W ; 180~528VAC/150W • 5 years warranty
9
LPF series
16~90W
• PFC Function • Plastic Case
10
23
• 3 in 1 Dimming Function • IP67
• PFC Function
PLC series
ULP series
30~96W
SPD series
20~96W
• 20kA Surge Protection Device • Plastic Case
• PFC Function • Plastic Case • IP64
12
HLN series
40~80W
24
• 3 in 1 Dimming Function
LCM series
40~60W
25
• DALI Interface and Push DIM
• IP65 & IP67
26
Waterproof Output Connector
20~60W
27
How to Choose A Suitable LED Power Supply?
40~80W
28
Quick Selection Map
29
Comparison Chart
• PFC Function • PCB Type
HLP series
96~240W
• 5 years warranty
• Multiple-Stage C.C. Level Selectable by DIP S.W.
15
HBG series
• 3 in 1 Dimming Function
• Plastic Case with Push Terminal I/O
PLP series
Single Channel DC/DC Driver
• PFC Function • Circular Shape Metal Case
• PFC Function
14
LDD series
• Plastic Case • Constant Current Output • Pin Style / Wire Style / SMD Style
• PFC Function • Plastic Case • IP64
13
150W
• U-bracket Type • PFC Function • Built-in lighting fixture
• Screw Terminal I/O
PLN series
70W
• Rectangular Metal Case • IP65
• PFC Function • Plastic Case
11
HSG series
• PFC Function • PCB Type • 3 in 1 Dimming Function
1
12~35W Single Output LED Power Supply Features •2Universal AC input / Full range •2Fully isolated plastic case •2Protections: Short circuit / Overload (APV only) / Over voltage •2Constant voltage design (C.V. mode) for APV series •2Constant current design (C.C. mode) for APC series • IP30 design • Withstand 300VAC surge input for 5 seconds (APV/C-25/35)
APV-12/16
• Class 2 power unit / Pass LPS • Isolation class II, no F.G. •2Cooling by free air convection •2100% full load burn-in test •2Low cost, high reliability • Suitable for LED lighting and moving sign applications •22 years warranty
APC-12/16
APV-25/35
APC-25/35
NE W
INPUT O UT P U T
AC input voltage range
90~264VAC ; 127~370VDC
AC inrush current (max.)
APC/V-12: Cold start, 70A at 230VAC APC-16: Cold start, 45A at 230VAC APV-16: Cold start, 50A at 230VAC
Overload protection
(APV only)
Range
>105% rated output current
Type
Hiccup up mode, auto-recovery
Over voltage protection
110%~145% rated output voltage
Withstand voltage
I/P-O/P: 3.75kVAC
Working temperature
-30~+70OC (refer to output derating curve)
Vibration
10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes
Safety standards
UL8750 approved; Design refer to TUV EN60950-1
Design refer to TUV EN60950-1, UL8750
EMC standards
EN55015, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11
UL rated, 18AWGx2C (15cm)
UL rated, 18AWGx2C (15cm)
Output UL rated, 20AWGx2C (15cm)
UL rated, 18AWGx2C (15cm)
Input
Connection
Dimension (LxWxH)(mm)
APV-12 Series Model No.
77x 40x 29
84x 57x 29.5
APC-12 Series
(C.V. mode) Output
(C.C. mode)
Tol.
R&N
Effi.
Model No.
Output
Io Tol.
R&N
Effi.
APV-12-5 APV-12-12 APV-12-15
5V, 0~2.0A 12V, 0~1.0A 15V, 0~0.8A
±5% ±5% ±5%
100mV 120mV 120mV
76% 82% 82%
APC-12-350
9~36V, 350mA
±8%
300mV
82%
APC-12-700
9~18V, 700mA
±8%
250mV
80%
APV-12-24
24V, 0~0.5A
±5%
150mV
84%
APV-16 Series Model No.
(C.V. mode) Output
Tol.
R&N
Effi.
APV-16-5 APV-16-12 APV-16-15
5V, 0~2.60A 12V, 0~1.25A 15V, 0~1.00A
±5% ±5% ±5%
100mV 120mV 120mV
76% 80% 81%
APV-16-24
24V, 0~0.67A
±5%
150mV
83%
APV-25 Series
(C.V. mode)
APC-16 Series Model No.
(C.C. mode) Output
(for 700mA)
(for 350mA)
Io Tol.
R&N
Effi.
APC-16-350
12~48V, 350mA
±8%
300mV
84%
APC-16-700
9~24V, 700mA
±8%
250mV
83%
APC-25 Series Model No.
(C.C. mode) Output
Io Tol.
R&N
Effi.
±8%
300mV
83%
Model No.
Output
Tol.
R&N
Effi.
APC-25-350
25~70V, 350mA
APV-25-5 APV-25-12 APV-25-15 APV-25-24
5V, 0~3.5A 12V, 0~2.1A 15V, 0~1.68A 24V, 0~1.05A
±5% ±5% ±5% ±5%
120mV 150mV 150mV 150mV
75.5% 82.0% 83.0% 83.0%
APC-25-500
15~50V, 500mA
±8%
300mV
83%
APC-25-700
11~36V, 700mA
±8%
300mV
83%
±8%
300mV
83%
APV-25-36
36V, 0~0.7A
±5%
150mV
84.0%
APV-35 Series Model No. APV-35-5 APV-35-12 APV-35-15 APV-35-24 2
Cold start, 45A at 230VAC
APV-35-36
Output
36V, 0~1.0A
9~24V, 1050mA
APC-35 Series
(C.V. mode)
5V, 0~5.0A 12V, 0~3.0A 15V, 0~2.4A 24V, 0~1.5A
APC-25-1050
Tol.
R&N
Effi.
Model No.
±5% ±5% ±5% ±5%
120mV 150mV 150mV 180mV
76.5% 83.0% 84.0% 84.0%
APC-35-350
±5%
180mV
85.0%
(C.C. mode) Io Tol.
R&N
Effi.
28~100V, 350mA
±8%
350mV
84%
Output
APC-35-500
25~70V, 500mA
±8%
350mV
84%
APC-35-700
15~50V, 700mA
±8%
350mV
84%
APC-35-1050
11~33V, 1050mA
±8%
350mV
84%
18~100W Single Output LED Power Supply Features • • • • • •
Isolation class II, no F.G. W ithstand 300VAC surge input for 5 seconds (except for LPH/LPL-18) Cooling by free air convection 100% full load burn-in test Low cost, high reliability Suitable for LED-based decorative/architectural lighting, LED stage and theater lighting, and LED electronic displays • 2 years warranty
• L PV: Universal AC input / Full range LPH-18: 180~264VAC input only LPL - 18: 90~132VAC input only • Fully encapsulated with IP67 level • Protections: Short circuit / Overload / Over voltage / Over temperature (LPH-18/LPL-18 only) • Constant voltage design (C.V. mode) • Class 2 power unit / Pass LPS (except for LPV-100)
LPL-18
LPH-18
LPV-20
LPV-35
LPV-100
LPV-60
INPUT
OUTPUT
AC input voltage range
90~132VAC
180~264VAC
90~264VAC
AC inrush current (max.)
Cold start, 40A at 115VAC
Cold start, 50A at 230VAC
Cold start, 70A at 230VAC
Overload Protection
Range
>105%
Type
Hiccup mode, auto-recovery
Cold start, Cold start, 55A at 230VAC 60A at 230VAC
Cold start, 75A at 230VAC
-30~+65 OC
-25~+70 OC
110%~150%
Over voltage protection
115%~135% rated output voltage
Withstand voltage
I/P-O/P: 3kVAC
Working temperature
-30~+70 OC
Vibration
10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes
Safety standards
TUV EN60950-1, EN61347-1, EN61347-2-13 approved for LPH-18
EMC standards
FCC part 15 class B
TUV EN60950-1(LPV-20 only), IEC61347-1, IEC61347-2-13 (LPV-35 only), UL1310 (except for LPV-60-5 & LPV-100), UL879 (except for LPV-35/100 & LPV-60-5) approved
EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11
Input Connection
Output
UL rated, 18AWGx2C (60cm)
UL rated, 18AWGx2C (60cm)
18AWGx2C (30cm)
UL rated,18AWGx2C (30cm)
UL rated, 16AWGx2C (60cm)
UL rated, 14AWGx2C (30cm)
140x 30x 22
118x 35x 26
148x 40x 30 162.5x 42.5x 32 190x 52x 37
Dimension (LxWxH)(mm)
LPL-18 Series
(C.V. mode)
Model No.
(LVD)
Output
Tol.
R&N
Effi.
LPL-18-12
12V, 0~1.5A
±3%
120mV
80%
LPL-18-24
24V, 0~0.75A
±3%
150mV
83%
LPL-18-36
36V, 0~0.5A
±3%
200mV
84%
LPH-18 Series Model No.
LPV-35 Series Model No. LPV-35-5 LPV-35-12 LPV-35-15 LPV-35-24 LPV-35-36
Model No. LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 LPV-60-48
Tol.
R&N
Effi.
LPH-18-12
12V, 0~1.5A
±3%
120mV
78%
LPH-18-24
24V, 0~0.75A
±3%
150mV
82%
LPH-18-36
36V, 0~0.5A
±3%
200mV
83%
Output
Tol.
R&N
Effi.
Model No.
5V, 0~3.0A
±5%
80mV
77%
LPV-20-12
12V, 0~1.67A
±5%
120mV
81%
LPV-20-15
15V, 0~1.33A
±5%
120mV
83%
LPV-20-24
24V, 0~0.84A
±5%
150mV
83%
LPV-100-5 LPV-100-12 LPV-100-15 LPV-100-24 LPV-100-36 LPV-100-48
Model No. LPV-20-5
(C.V. mode)
Output 5V, 0~5.0A (peak 6A) 12V, 0~3.0A 15V, 0~2.4A 24V, 0~1.5A 36V, 0~1.0A
LPV-60 Series
(C.V. mode) Output
LPV-20 Series
-30~+70 OC
(C.V. mode)
Output 5V, 0~8.0A 12V, 0~5.0A 15V, 0~4.0A 24V, 0~2.5A 36V, 0~1.67A 48V, 0~1.25A
LPV-100 Series
(C.V. mode)
Tol. ±6% ±5% ±5% ±5% ±5%
R&N 80mV 120mV 120mV 150mV 150mV (for 48V only)
Tol. ±8% ±5% ±5% ±5% ±5% ±5%
Effi. 77% 84% 84% 85% 85% (for 12~36V)
R&N 80mV 120mV 120mV 150mV 150mV 150mV
Effi. 76% 83% 83% 86% 86% 86%
Tol.
R&N
Effi.
±8% ±5% ±5% ±5% ±5% ±5%
80mV 120mV 120mV 150mV 150mV 150mV
80% 85% 87% 88% 88% 89%
(C.V. mode) Output
5V, 0~12.0A 12V, 0~8.5A 15V, 0~6.7A 24V, 0~4.2A 36V, 0~2.8A 48V, 0~2.1A
3
18~60W Single Output LED Power Supply Features • L PC: Universal AC input / Full range
• Class 2 power unit / Pass LPS
LPHC-18: 180~264VAC input only
• Isolation class II, no F.G.
LPL C -18: 90~132VAC input only
• Cooling by free air convection
• Fully encapsulated with IP67 level
• 100% full load burn-in test
• Protections: S hort circuit / Over voltage /
• Low cost, high reliability
Over temperature ( LPLC/LPHC-18 only )
• S uitable for LED-based decorative / architectural lighting,
• Constant current design (C.C. mode)
LED stage and theater lighting, and LED electronic displays
• W ithstand 300VAC surge input for 5 seconds
• 2 years warranty
(except for LPHC/LPLC-18)
LPHC-18
LPLC-18
LPC-20
LPC-35
LPC-60
INPUT
OUTPUT
AC input voltage range
90~132VAC
180~264VAC
90~264VAC
AC inrush current (max.)
Cold start, 40A at 115VAC
Cold start, 50A at 230VAC
Cold start, 70A at 230VAC
Over voltage protection
105%~135% rated output voltage
Withstand voltage
I/P-O/P: 3kVAC
Working temperature
-30~+70OC
Vibration
10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes
Safety standards
Design refer to UL1310, EN60950-1
UL1310, UL879 (LPC-20 only), TUV EN60950-1(LPC-20 only) approved
EMC standards
FCC part 15 class A (LPLC-18), EN55022 class A, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11
EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11
UL rated, 18AWGx2C (30cm)
UL rated, 18AWGx2C (60cm)
UL rated, 18AWGx2C (60cm)
140x 30x 22
118x 35x 26
148x 40x 30
Connection
Input Output
Dimension (LxWxH)(mm)
LPLC-18 Series
(C.C. mode)
(LVD)
LPC-35 Series
200mV
85%
LPC-35-1050
9~30V, 1050mA
±5%
200mV
85%
LPC-35-1400
9~24V, 1400mA
±5%
200mV
85%
Model No.
82%
LPC-35-700
LPLC-18-700
6~25V, 700mA
±8%
250mV
80%
R&N
Effi.
LPHC-18-350
6~48V, 350mA
±8%
300mV
80%
LPHC-18-700
6~25V, 700mA
±8%
250mV
80%
4
(C.C. mode)
(for 350mA)
(for 700mA)
Model No.
Output
Io Tol.
R&N
Effi.
LPC-20-350
9~48V, 350mA
±5%
200mV
83%
LPC-20-700
9~30V, 700mA
±5%
200mV
83%
Output
LPC-60 Series Model No.
LPC-20 Series
(for 1050mA & 1400mA)
±5%
Effi.
300mV
Io Tol.
(for 700mA)
9~48V, 700mA
R&N
±8%
Output
(C.C. mode)
162.5x 42.5x 32
Effi.
Io Tol.
Model No.
UL rated, 16AWGx2C (60cm)
R&N
Output 6~48V, 350mA
(C.C. mode)
Cold start, 60A at 230VAC
Io Tol.
Model No. LPLC-18-350
LPHC-18 Series
Cold start, 55A at 230VAC
(C.C. mode) Output
(for 1050mA & 1400mA)
(for 1750mA)
Io Tol.
R&N
Effi.
LPC-60-1050
9~48V, 1050mA
±5%
200mV
87%
LPC-60-1400
9~42V, 1400mA
±5%
200mV
85%
LPC-60-1750
9~34V, 1750mA
±5%
200mV
87%
30~60W Single Output LED Power Supply Features •2Universal AC input / Full range
• Class 2 power unit / Pass LPS
•2Fully isolated plastic case with IP64 level
• Isolation class II, no F.G.
•2Built-in constant current limiting circuit with adjustable OCP level
• Cooling by free air convection
•2Protections: Short circuit / Over current / Over voltage
• Suitable for economical LED indoor lighting and LED electronic
•2Optional dimming function: 1.1~10VDC(D type) or PWM (P type) controlled
displays •22 years warranty
ELN-30
ELN-60
INPUT O UT P U T (standard)
O UT P U T (Dimming Funct ion)
AC input voltage range
90~264VAC ; 127~370VDC
AC inrush current (max.)
Cold start, 55A at 230VAC
DC adjustment range
±10% rated output voltage
Current adjustment range
75%~103%
Over current protection
95%~110% constant current limiting, auto-recovery
Over voltage protection
Cold start, 60A at 230VAC
Range
110%~150% rated output voltage
Type
Shut down o/p voltage, re-power on to recover
Withstand voltage
I/P-O/P: 3kVAC
Working temperature
-20~+60OC (refer to output derating curve)
Vibration
10~500Hz, 2G 10 minutes /1 cycle, period for 60 minutes each along X, Y, Z axes
Safety standards
UL1310 approved; Design refer to TUV EN60950-1
EMC standards
EN55022 class B, EN61000-3-2 class A, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 Input
UL rated, SVT 18AWGx2C (32cm)
UL rated, SVT 18AWGx2C (30cm)
Output
Without dimming: UL rated, SVT 18AWGx2C (32cm) With dimming(optional): UL2464 18AWGx4C (32cm)
Without dimming: UL rated, SVT 18AWGx2C (30cm) With dimming(optional): UL2464 18AWGx4C (30cm)
Dimension (LxWxH)(mm)
145x 47x 30
181x 61.5x 35
Packing
0.26kg ; 60pcs / 16.6kg
0.4kg ; 24pcs / 11.0kg
Connection
ELN-30 Series
(for 48V only)
ELN-60 Series
(for 5~27V)
Output
Tol.
R&N
Effi.
Model No.
ELN-30-5
5V, 0~5.0A
±5%
80mV
75%
ELN-60-9
ELN-30-9
9V, 0~3.4A
±5%
100mV
80%
ELN-30-12
12V, 0~2.5A
±5%
120mV
82%
ELN-30-15
15V, 0~2.0A
±5%
120mV
82%
ELN-30-24
24V, 0~1.25A
±5%
150mV
ELN-30-27
27V, 0~1.12A
±5%
150mV
ELN-30-48
48V, 0~0.63A
±5%
250mV
Model No.
► ►Dimming
(for 48V only)
Output
(for 9~27V)
Tol.
R&N
Effi.
9V, 0~5.0A
±5%
120mV
82%
ELN-60-12
12V, 0~5.0A
±5%
120mV
85%
ELN-60-15
15V, 0~4.0A
±5%
150mV
86%
85%
ELN-60-24
24V, 0~2.5A
±5%
150mV
87%
85%
ELN-60-27
27V, 0~2.3A
±5%
200mV
87%
87%
ELN-60-48
48V, 0~1.3A
±5%
250mV
88%
Control (optional)
Through the dimming function, output current of
D Type :
1.1~10Vdc external control signal
PWM control signal V
DIM+
ELN series can be adjusted to reduce the energy consumption or adjust the brightness of LEDs connecting to it. Two kinds of control signal are
P Type :
Vdc
ELN Control input
+
f: 100Hz ~ 3KHz f
10V
accepted: 1.1~10VDC (D-type option) or PWM signal (P-type option). Vdc 1.1~10V
DIM-
Order No.: ELN- 30 - 5 D
t1
Duty=
t2
t1 , 0~100% t1+t2
f
Low: 0V High: 10V
Order No.: ELN- 30 - 5 P
5
16~ 60W Single Ou t pu t AC Di m m abl e Pow e r Un i t Features
• I P30 design • C lass 2 power unit / Pass LPS (PCD-16/25) •2Isolation class II, no F.G. • P rotections: Short circuit / Over temperature • C ooling by free air convection • 3 years warranty
•AC phase-cut dimming, work with leading edge and trailing edge TRIAC dimmers •PCD-16/25: 115VAC or 230VAC input PCD-40/60: 230VAC input only • B uilt-in active PFC function • F ully isolated plastic case • C onstant current design
PCD-16/25
PCD-40/60
NE W
INPUT
(A t y p e )
INPUT
OUTPUT
(B t y p e )
AC input voltage range
115VAC (90~135VAC) or 230VAC (180~295VAC)
230VAC (180~295VAC)
AC inrush current (max.)
Cold start, 10A at 230VAC
PCD-40: Cold start, 11A at 230VAC PCD-60: Cold start, 13A at 230VAC
Withstand voltage
I/P - O/P: 3.75kVAC
Working temperature
-30~+60ºC (refer to output derating curve)
Safety standards
UL8750 (PCD-16/25 only), ENEC EN61347-1, EN61347-2-13, EN62384(B-Type only) approved (PCD-40/60 pending)
EMC standards
A-Type: FCC part 18 non-consumer equipment B-Type: EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection
Input
A-Type: UL1430 18AWGx2C (7.5cm); B-Type: NISPT-1 18AWGx2C (7.5cm)
Output
UL1430 18AWGx2C (15cm)
Dimension (LxWxH)(mm)
PCD-16 Series Mod e l N o . PCD-16-350
84x 57x 29.5
(for 350mA) (for 700~1400mA)
O ut p ut 24~48V, 350mA
128x 60x 31.5 (B Type) (A Type)
Io Tol . ±5%
R& N 4.6V
(B Type)
PCD-60 Series
ENEC/CB/CE pending
E ffi.
Model No.
Ou tpu t
Io T ol.
R&N
82.0%
PCD-60-500B
65~115V, 500mA
±5%
10.2V
87%
PCD-60-700B
50~86V, 700mA
± 5%
5.6V
86%
± 5%
3.8V
86%
E f f i.
PCD-16-700
16~24V, 700mA
±5%
2.7V
81.0%
PCD-60-1050B
34~57V, 1050mA
PCD-16-1050
12~16V, 1050mA
±5%
2.2V
80.5%
PCD-60-1400B
25~43V, 1400mA
±5%
3.4V
85%
PCD-16-1400
8~12V, 1400mA
±5%
2.0V
80.0%
PCD-60-1750B
20~34V, 1750mA
±5%
3.3V
85%
= A o r B-T y p e ; A -T y pe: 90~135VAC , B-Type: 180~295V AC
PCD-25 Series Mod e l N o . PCD-25-350
(for 350/700mA) (for 1050/1400mA)
(B Type) (A Type)
(B Type)
O ut put
Io Tol .
R& N
Effi.
40~58V, 350mA
±5%
4.6V
82.0%
PCD-25-700
24~36V, 700mA
±5%
2.7V
81.0%
PCD-25-1050
16~24V, 1050mA
±5%
2.2V
80.5%
PCD-25-1400
12~18V, 1400mA
±5%
2.0V
80.0%
= A o r B-T y p e ; A -T y pe: 90~135VAC , B-Typ e: 180~295V AC
PCD-40 Series Mod e l N o .
6
-30~+50ºC (refer to output derating curve)
ENEC/CB/CE pending O ut put
Io Tol .
R& N
E ffi.
PCD-60-2000B
18~30V, 2000mA
± 5%
2.4V
85%
PCD-60-2400B
15~25V, 2400mA
± 5%
2.4V
84%
► ►Dimmer Compatibility Chart Ma n u fa c tu rer
Dimmer Model
LUTRON
SKYLARK SF-12P-277
(277VAC / 60Hz)
LUTRON
DVF-103P-277
(277VAC / 60Hz)
LUTRON
SKYLARK SF-10P
(120VAC / 60Hz)
LUTRON
SKYLARK S-600P
(120VAC / 60Hz)
LUTRON
SKYLARK DVF-103P
(120VAC / 60Hz)
LEVITON
ILLUMATECH TM Cat.No.IP106 (120VAC / 60Hz)
LEVITON
SURESLIDE TM Cat.No.6633-P
LEVITON
SURESLIDE TM Cat. NO.6615-P (120VAC / 60Hz)
(120VAC / 60Hz)
JUNG
Licht-Management 225 T DE
JUNG
Licht-Management 225 NV DE (230VAC / 50Hz)
(230VAC / 50Hz)
PCD-40-350B
65~115V, 350mA
±5%
9.5V
87%
BERKER
Tronic-Drehdimmer 286710
(230-240VAC / 50Hz)
PCD-40-500B
45~80V, 500mA
±5%
5.0V
87%
BE LICHTREGLER
T39.01
(230VAC / 50Hz)
BE LICHTREGLER
T46
(230VAC / 50Hz)
CLIPSAL
32E450UDM
(220-240VAC / 50Hz)
CLIPSAL
NO 32E450TM
(220-240VAC / 50Hz)
PCD-40-700B
34~57V, 700mA
±5%
3.1V
86%
PCD-40-1050B
22~38V, 1050mA
±5%
2.6V
86%
PCD-40-1400B
17~29V, 1400mA
±5%
2.5V
85%
PCD-40-1750B
13~23V, 1750mA
±5%
2.4V
85%
► Conduction angle: 30 degrees (min.) / 180 degrees (max.) ► For PCD-16/25/40/60 only
16~ 60 W Single O u t pu t wi t h PFC Features • C lass 2 power unit / Pass LPS (PLD-16/25)
•PLD-25: Universal AC input (up to 295VAC) / Full range
•2Isolation class II, no F.G.
PLD-16: 115VAC or 230VAC input
• P rotections: Short circuit / Over temperature
PLD-40/60: 230VAC input only •Built-in active PFC function
• S uitable for indoor LED lighting applications
• F ully isolated plastic case
• C ooling by free air convection
• C onstant current design
• 3 years warranty
• I P30 design
PLD-25
PLD-16
PLD-40
PLD-60
NE W
INP UT (A-Type)
INP UT
OUTPUT
( B-Type & PLD-25)
AC input voltage range
115VAC (90~135VAC) or 90~295VAC 230VAC (180~295VAC)
230VAC (180~295VAC)
AC inrush current (max.)
Cold start, 20A at 230VAC
Cold start, 25A at 230VAC
Withstand voltage
I/P - O/P: 3.75kVAC
Short circuit protection
Hiccup mode, auto-recovery
Over Temp. protection
95ºC± 10ºC (RTH1) shut down o/p voltage, re-power on to recover
105ºC± 5ºC (STW1) shut down o/p voltage, auto-recovery
Working temperature
-30~+50ºC
-30~+50ºC
Safety standards
UL8750 (PLD-16/25), ENEC EN61347-1, EN61347-2-13, EN62384 (except for A-Type) approved (PLD-40/60 pending)
EMC standards
A-Type & PLD-25: FCC part 18 non-consumer equipment B-Type & PLD-25: EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4,2,3,4,5,6,8,11, EN61547
Connection
Cold start, 15A at 230VAC
-30~+60ºC
Input
A-Type: UL1430 18AWGx2C (7.5cm) B-Type & PLD-25: NISPT-1 18AWGx2C (7.5cm)
Output
UL1430 18AWGx2C (15cm)
Dimension (LxWxH)(mm)
PLD-16 Series Mod e l N o .
84x 57x 29.5
(for 350mA)
O ut p ut
128x 60x 31.5
(for 700~1400mA)
(B Type) (A Type) (B Type)
Io Tol .
R& N
E ffi.
PLD-16-350
24~48V, 350mA
±5%
4.6V
84.5%
PLD-16-700
16~24V, 700mA
±5%
2.7V
84.5%
PLD-16-1050
12~16V, 1050mA
±5%
2.2V
84.0%
PLD-16-1400
8~12V, 1400mA
±5%
2.0V
82.5%
PLD-40 Series
ENEC/CB/CE pending Ou tpu t
Io T ol.
R&N
E f f i.
PLD-40-350B
65~115V, 350mA
±5%
9.5V
88%
PLD-40-500B
45~80V, 500mA
±5%
5.0V
88%
Model No.
PLD-40-700B
34~57V, 700mA
±5%
3.1V
87%
PLD-40-1050B
22~38V, 1050mA
±5%
2.6V
87%
PLD-40-1400B
17~29V, 1400mA
± 5%
2.5V
86%
PLD-40-1750B
13~23V, 1750mA
± 5%
2.4V
86%
= A o r B-T y p e ; A -T y pe: 90~135VAC , B-Type: 180~295V AC
PLD-25 Series Mod e l N o . PLD-25-350
(for 350/700mA)
O ut put 36~58V, 350mA
PLD-60 Series
(for 1050/1400mA)
Io Tol . ±5%
R& N 4.6V
Effi. 85%
PLD-25-700
24~36V, 700mA
±5%
2.7V
86%
PLD-25-1050
16~24V, 1050mA
±5%
2.2V
85%
PLD-25-1400
12~18V, 1400mA
±5%
2.0V
84%
ENEC/CB/CE pending Ou tpu t
Io Tol.
R&N
E f f i.
PLD-60-500B
65~115V, 500mA
±5%
10.2V
88%
Model No.
PLD-60-700B
50~86V, 700mA
±5%
5.6V
87%
PLD-60-1050B
34~57V, 1050mA
±5%
3.8V
87%
PLD-60-1400B
25~43V, 1400mA
± 5%
3.4V
86%
PLD-60-1750B
20~34V, 1750mA
± 5%
3.3V
86%
PLD-60-2000B
18~30V, 2000mA
±5%
2.4V
86%
PLD-60-2400B
15~25V, 2400mA
±5%
2.4V
85% 7
12~ 40 W Single O u t pu t wi t h PFC Features • Universal AC input (up to 295VAC) / Full range
• Isolation class II, no F.G.
• Built-in active PFC function
• Cooling by free air convection
•2Protections: Short circuit / Over temperature(PLM-40)
• Low cost, high reliability
• Fully isolated plastic case
• Suitable for indoor LED lighting applications
• Constant current design
•22 years warranty
• IP30 design
PLM-12
PLM-25
PLM-40
De U ve nd lop er me nt
De U ve nd lop er me nt
AC input voltage range
90~295VAC; 127~417VDC
AC inrush current (max.)
Cold start, 40A at 230VAC
Setup time
2000ms at full load and 230VAC
Short circuit protection
Hiccup mode, auto-recovery
Over temperature (PLM-40)
95ºC ±10ºC (RTH1) shut down o/p voltage, re-power on to recover
Withstand voltage
I/P-O/P: 3.75kVAC
Working temperature
-30~+45ºC (refer to output derating curve)
Safety standards
Design refer to UL8750, ENEC EN61347-1, EN61347-2-13, EN62384
EMC standards
Design refer to EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
1500ms at full load and 230VAC
-30~+50ºC (refer to output derating curve)
Connection (Input / Output) 2+2P push terminal block Dimension (LxWxH)(mm)
145x 38x 22
PLM-12 Series
UL/CUL/ENEC/CB/CE pending Output
Io Tol.
R&N
Effi.
PLM-12-350
18~36V, 350mA
±5%
3.6V
85%
PLM-12-500
12~24V, 500mA
±5%
2.4V
84%
PLM-12-700
9~18V, 700mA
±5%
1.8V
83%
PLM-12-1050
6~12V, 1050mA
±5%
1.2V
82%
Model No.
PLM-25 Series
PLM-40 Series Model No.
UL/CUL/ENEC/CB/CE pending Output
Io Tol.
R&N
Effi.
PLM-40-350
53~105V, 350mA
±5%
10V
88%
PLM-40-500
40~80V, 500mA
±5%
8V
87%
PLM-40-700
28~55V, 700mA
±5%
6V
86%
PLM-40-1050
19~38V, 1050mA
±5%
4V
86%
PLM-40-1400
15~29V, 1400mA
±5%
3V
85%
PLM-40-1750
12~23V, 1750mA
±5%
2.5V
85%
UL/CUL/ENEC/CB/CE pending Output
Io Tol.
R&N
Effi.
PLM-25-350
36~72V, 350mA
±5%
7.2V
88%
PLM-25-500
25~50V, 500mA
±5%
5.0V
87%
PLM-25-700
18~36V, 700mA
±5%
3.6V
86%
PLM-25-1050
12~24V, 1050mA
±5%
2.4V
86%
Model No.
8
175x 42x 24
16~ 90W Single O u t pu t wit h PFC Features
• Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC function • Fully isolated plastic case • Isolation class II, no F.G. • Class 2 power unit / Pass LPS
LPF-16(D)/25(D)
• Built-in 3 in 1 dimming function (1~10VDC, PWM signal or resistance) for D type • Fully encapsulated with IP67 level [optional for LPF-16(D)] • Cooling by free air convection • Suitable for LED lighting and moving sign applications • Suitable for dry, damp, and wet location • 3 years warranty
LPF-40(D)/60(D)
LPF-90(D)
NE W
INPUT O UT PU T
(Non-Dimming Function)
O UT PU T (Dimming Function)
AC input voltage range
90~305VAC ; 127~431VDC
AC inrush current (max.)
LPF-16(D): Cold start, 45A LPF-25(D): Cold start, 50A
Over current protection
95% ~108% constant current, auto-recovery
Over voltage protection
110%~150% rated output voltage
Withstand voltage
I/P - O/P: 3.75kVAC
Working temperature
-35~+70ºC
Safety standards
UL8750, ENEC EN61347-1, EN61347-2-13, EN62384, PSE J61347-1, J61347-2-13 approved for LPF-16(D)/25(D); UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved for LPF-40(D)/60(D)/90(D)
EMC standards Input
EN55015, EN61547, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11 UL rated, SJTW 18AWGx2C (30cm)
Connection
Output
Dimension (LxWxH)(mm)
LPF-16
LPF-25
-12 -15 -20 -24 -30 -36 -42 -48 -54
LPF-40
-12 -15 -20 -24 -30 -36 -42 -48 -54
LPF-40/60: UL rated, SVT 18AWGx2C (30cm) LPF-40D/60D: UL2464 18AWGx2C(30cm)+22AWGx2C (30cm)
LPF-90: UL rated, SVT 18AWGx2C (30cm) LPF-90D: UL2464 18AWGx4C (30cm)
148x 40x 32
162.5x 43x 32
161x 61x 36
-12 -15 -20
PS E
TUV Rheinland Product Safety
Model No.
O u t put
Tol .
R& N
E ffi.
12V, 0~1.34A 15V, 0~1.07A 20V, 0~0.80A 24V, 0~0.67A 30V, 0~0.54A 36V, 0~0.45A 42V, 0~0.39A 48V, 0~0.34A 54V, 0~0.30A
±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV
83.0% 83.0% 84.5% 84.5% 84.5% 85.0% 85.0% 85.0% 84.5%
TUV Rheinland Product Safety
PS E
O u t put
Tol .
R& N
E ffi.
12V, 0~2.10A 15V, 0~1.67A 20V, 0~1.25A 24V, 0~1.05A 30V, 0~0.84A 36V, 0~0.70A 42V, 0~0.60A 48V, 0~0.53A 54V, 0~0.47A
±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV
84.0% 84.0% 85.0% 85.5% 85.5% 85.5% 85.5% 86.0% 86.0%
Series
Mod e l N o . LPF-40 LPF-40 LPF-40
LPF-16/25: UL rated, SVT 18AWGx2C (30cm) LPF-16D/25D: UL rated, SJTW 18AWGx4C (30cm)
Series
Mod e l N o . LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25 LPF-25
Cold start, 55A at 230VAC
-40~+70ºC (refer to output derating curve)
Series
Mod e l N o . LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16 LPF-16
LPF-40(D): Cold start, 50A LPF-60(D): Cold start, 55A
(for 48~54V)
TUV Rheinland Product Safety
(for 12~42V)
PS E
O u t put
Tol .
R& N
E ffi.
12V, 0~3.34A 15V, 0~2.67A 20V, 0~2.00A
±4.0% ±4.0% ±4.0%
150mV 150mV 150mV
84.0% 85.0% 86.0%
LPF-40 LPF-40 LPF-40 LPF-40 LPF-40 LPF-40
LPF-60
-24 -30 -36 -42 -48 -54
LPF-90
-12 -15 -20 -24 -30 -36 -42 -48 -54
R&N
E f f i.
150mV 200mV 250mV 250mV 250mV 350mV
87.0% 88.0% 88.0% 88.5% 89.0% 89.0%
(for 48~54V)
-15 -20 -24 -30 -36 -42 -48 -54
TUV Rheinland Product Safety
(for 12~42V)
PS E
Ou tpu t
T ol.
R &N
E f f i.
12V, 0~5.00A 15V, 0~4.00A 20V, 0~3.00A 24V, 0~2.50A 30V, 0~2.00A 36V, 0~1.67A 42V, 0~1.43A 48V, 0~1.25A 54V, 0~1.12A
±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV
86% 87% 88% 89% 90% 90% 90% 90% 90%
Series
Model No. LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 LPF-90 LPF-90
T ol. ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
Series
Model No. LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60 LPF-60
Ou tpu t 24V, 0~1.67A 30V, 0~1.34A 36V, 0~1.12A 42V, 0~0.96A 48V, 0~0.84A 54V, 0~0.76A
(for 48~54V)
TUV Rheinland Product Safety
(for 15~42V)
PS E
Ou tpu t
Tol.
R &N
E f f i.
15V, 0~5.00A 20V, 0~4.50A 24V, 0~3.75A 30V, 0~3.00A 36V, 0~2.50A 42V, 0~2.15A 48V, 0~1.88A 54V, 0~1.67A
±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0% ±4.0%
150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV
89.0% 89.5% 90.0% 90.5% 90.5% 90.5% 90.5% 90.5%
= Blank, D ; Blank: without dimming function , D: with dimming function 9
30~ 96W Single O u t pu t wit h PFC Features
• Universal AC input / Full range
• Isolation class II, no F.G. for PLC-30
• Fully isolated plastic case with screw terminal style of I/O
• Cooling by free air convection
• Built-in constant current limiting circuit (C.V.+C.C. mode)
• Protections: Short circuit / Over current / Over voltage /
• Adjustable output voltage and current level • Built-in active PFC function, PF>0.9 for 75% of load or higher • High efficiency up to 89%
• Suitable for LED lighting and moving sign applications
• Class 2 power unit / Pass LPS
• 2 years warranty
PLC-30
PLC-45
PLC-100
PLC-60
AC input voltage range
90~264VAC ; 127~370VDC
AC inrush current (max.)
Cold start, 35A at 230VAC
Cold start, 40A at 230VAC
DC adjustment range
90%~110% rated output voltage
85%~100% rated output voltage
Current adjustment range
75%~103%
Over current protection
100%~110% constant current limiting, auto-recovery
Over voltage protection
110%~155% rated output voltage 115%~140% rated output voltage 107%~135% rated output voltage
Setup time
2000ms at full load and 230VAC
1500ms at full load and 230VAC
Withstand voltage
I/P-O/P: 3.75kVAC
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC
Working temperature
-30~+50OC (refer to output derating curve)
Safety standards
UL1310, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; TUV EN60950-1 approved for PLC-100 only
EMC standards
EN55015, EN55022 class B (PLC-45/60/100), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection (Input / Output)
2+2P screw terminal block
3+2P screw terminal block
Dimension (LxWxH)(mm)
160x 46x 30
181.5x 62x 35
200.5x 69.5x 35
Packing
0.2kg ; 70pcs / 15kg
0.41kg ; 30pcs / 13.3kg
0.52kg ; 25pcs / 14kg
PLC-30 Series
(for 48V only)
(for 9~36V)
75%~100%
TUV Rheinland Product Safety
95%~110% constant current limiting, auto-recovery
PLC-60 Series
PS E
95%~102% constant current limiting, auto-recovery 1200ms at full load and 230VAC
(for 12~36V)
(for 48V only)
PS E
Output
Tol.
R&N
Effi.
Model No.
Tol.
R&N
Effi.
±10%
2.6V
80.0%
PLC-60-12
12V, 0~5.0A
±10%
2.0V
85.0%
PLC-30-12
12V, 0~2.5A
±10%
2.0V
82.5%
PLC-60-15
15V, 0~4.0A
±10%
2.4V
86.0%
PLC-30-15
15V, 0~2.0A
±10%
2.6V
83.5%
PLC-60-20
20V, 0~3.0A
±10%
1.8V
87.5%
PLC-30-20
20V, 0~1.5A
±10%
2.6V
84.0%
PLC-60-24
24V, 0~2.5A
±10%
2.4V
87.0%
PLC-30-24
24V, 0~1.25A
±10%
2.4V
84.0%
PLC-60-27
27V, 0~2.3A
±10%
2.7V
88.0%
PLC-30-27
27V, 0~1.12A
±10%
2.3V
84.5%
PLC-60-36
36V, 0~1.7A
±10%
3.6V
89.0%
PLC-30-36
36V, 0~0.84A
±10%
3.6V
85.0%
PLC-60-48
48V, 0~1.3A
±10%
4.6V
89.0%
PLC-30-48
48V, 0~0.63A
±10%
3.7V
85.5%
PLC-45 Series
(for 48V only)
(for 12~36V)
TUV Rheinland Product Safety
Output
TUV Rheinland Product Safety
9V, 0~3.3A
Model No. PLC-30-9
PLC-100 Series
PS E
TUV Rheinland Product Safety
(for 12~36V)
(for 48V only)
PS E
Tol.
R&N
Effi.
Model No.
Output
Tol.
R&N
Effi.
PLC-45-12
12V, 0~3.8A
±10%
2.0V
83.5%
PLC-100-12
12V, 0~5.0A
±3%
150mV
83.0%
PLC-45-15
15V, 0~3.0A
±10%
2.4V
85.0%
PLC-100-15
15V, 0~5.0A
±3%
150mV
85.0%
20V, 0~4.8A
±3%
150mV
88.5%
Model No.
10
Over temperature • 100% full load burn-in test
Output
PLC-45-20
20V, 0~2.3A
±10%
1.8V
86.5%
PLC-100-20
PLC-45-24
24V, 0~1.9A
±10%
2.7V
86.5%
PLC-100-24
24V, 0~4.0A
±3%
150mV
88.5%
PLC-45-27
27V, 0~1.7A
±10%
2.7V
86.5%
PLC-100-27
27V, 0~3.55A
±3%
150mV
88.0%
PLC-45-36
36V, 0~1.25A
±10%
3.6V
87.5%
PLC-100-36
36V, 0~2.65A
±2%
150mV
88.0%
PLC-45-48
48V, 0~0.95A
±10%
4.6V
87.5%
PLC-100-48
48V, 0~2.0A
±2%
200mV
88.5%
20~96W Single Output with PFC Features •2Universal AC input (up to 295VAC) / Full range •2Fully isolated plastic case with IP64 level •2Built-in active PFC function, PF>0.9 for 75% of load or higher •2Protections: Short circuit / Over current / Over voltage / Over temperature •2Built-in constant current limiting circuit (C.V.+C.C. mode) •2Class 2 power unit / Pass LPS
PLN-20
•2Isolation class II, no F.G. for PLN-20/30 •2User adjustable output voltage (except for PLN-20) and current protection level •2Cooling by free air convection •2Suitable for LED lighting and moving sign applications •22 years warranty
PLN-30
PLN-45/60
PLN- 100
I NP UT PLN-20
PLN-30
PLN-45/60/100
O U T P UT PLN-20
PLN-30/45/60/100
AC input voltage range AC inrush current (max.)
90~295VAC ; 127~417VDC
90~277VAC; 127~392VDC
Cold start, 35A at 230VAC
Cold start, 40A at 230VAC
DC adjustment range
None
95%~108% rated output voltage
85%~100% rated output voltage
Current adjustment range
75%~100% 95%~110% constant current limiting, auto-recovery
75%~103% 100%~110% constant current limiting, auto-recovery
95%~110% constant current limiting, auto-recovery
95%~102% constant current limiting, auto-recovery
105%~142% rated output voltage
110%~155% rated output voltage
115%~140% rated output voltage
107%~135% rated output voltage
2300ms(setup time) at full load and 230VAC, no hold up time I/P-O/P: 3.75kVAC -30~+60 O C
2000ms(setup time) at 1500ms(setup time) at 1200ms, 80ms, 60ms full load and 230VAC, full load and 230VAC, at full load and 230VAC no hold up time no hold up time I/P-O/P: 3.75kVAC I/P-FG: 2kVAC O/P-FG: 0.5kVAC -30~+50 O C (refer to output derating curve)
Over current protection Over voltage protection Setup, rise, hold up time Withstand voltage Working temperature Safety standards
UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved for PLN-20 UL879, UL1310, UL8750(PLN-45/60), TUV EN61347-1, EN61347-2-13,PSE J61347-1, J61347-2-13 approved for PLN-30/45/60 UL879, UL1310, UL8750, TUV EN61347-1, EN61347-2-13, EN60950-1, PSE J61347-1, J61347-2-13 approved for PLN-100
EMC standards
EN55015, EN55022 class B (PLN-60/100 only), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Input Output Dimension (LxWxH) (mm) Connection
UL rated, UL1015 18AWGx2C (32cm)
UL rated, SVT 18AWGx2C (32cm)
UL rated, SVT 18AWGx3C (30cm)
UL rated, SVT 18AWGx3C (31cm)
UL rated, SVT 18AWGx2C (30cm)
UL rated, SVT 18AWGx2C (31cm)
148.5x 38.5x 28
145x 47x 30
181x 61.5x 35
200x 70.5x 35
PLN-20 Series Model No.
TUV Rheinland Product Safety
Output
PS E
Tol.
R&N
Effi.
PLN-20-12
12V, 0~1.6A
±10%
2.5V
80.0%
PLN-20-18
18V, 0~1.1A
±10%
3.0V
81.0%
PLN-20-24
24V, 0~0.8A
±10%
3.0V
82.0%
PLN-20-36
36V, 0~0.55A
±10%
3.0V
83.0%
PLN-20-48
48V, 0~0.42A
±10%
3.8V
PLN-30 Series Model No. PLN-30-9 PLN-30-12 PLN-30-15 PLN-30-20 PLN-30-24 PLN-30-27 PLN-30-36 PLN-30-48
PLN-45 Series Model No. PLN-45-12 PLN-45-15
TUV Rheinland Product Safety
(for 9~36V) (for 48V only) (for 9~36V)
Output 9V, 0~3.3A 12V, 0~2.5A 15V, 0~2.0A 20V, 0~1.5A 24V, 0~1.25A 27V, 0~1.12A 36V, 0~0.84A 48V, 0~0.63A (for 48V only)
Output 12V, 0~3.8A 15V, 0~3.0A
Tol. ±10% ±10% ±10% ±10% ±10% ±10% ±10% ±10%
R&N 2.6V 2.0V 2.6V 2.6V 2.6V 2.3V 4.5V 3.7V
Effi. 80.0% 82.5% 83.5% 84.0% 84.0% 84.5% 85.0% 85.5% TUV Rheinland Product Safety
(for 12~36V)
Tol. ±10% ±10%
83.5% PS E
R&N 2.0V 2.4V
PS E
Effi. 83.5% 85.0%
Model No. PLN-45-20 PLN-45-24 PLN-45-27 PLN-45-36 PLN-45-48
Output 20V, 0~2.3A 24V, 0~1.9A 27V, 0~1.7A 36V, 0~1.25A 48V, 0~0.95A
PLN-60 Series Model No. PLN-60-12 PLN-60-15 PLN-60-20 PLN-60-24 PLN-60-27 PLN-60-36 PLN-60-48
Model No. PLN-100-12 PLN-100-15 PLN-100-20 PLN-100-24 PLN-100-27 PLN-100-36 PLN-100-48
(for 48V only)
Output 12V, 0~5.0A 15V, 0~4.0A 20V, 0~3.0A 24V, 0~2.5A 27V, 0~2.3A 36V, 0~1.7A 48V, 0~1.3A
PLN-100 Series
Tol. ±10% ±10% ±10% ±10% ±10%
Tol. ±10% ±10% ±10% ±10% ±10% ±10% ±10%
PS E
R&N 2.0V 2.4V 1.8V 2.7V 2.7V 3.6V 4.6V (for 12~36V)
Tol. ±3% ±3% ±3% ±3% ±3% ±2% ±2%
Effi. 86.5% 86.5% 86.5% 87.5% 87.5% TUV Rheinland Product Safety
(for 12~36V)
(for 48V only)
Output 12V, 0~5.0A 15V, 0~5.0A 20V, 0~4.8A 24V, 0~4.0A 27V, 0~3.55A 36V, 0~2.65A 48V, 0~2.0A
R&N 1.8V 2.7V 2.7V 3.6V 4.6V
Effi. 85.0% 86.0% 87.5% 87.0% 88.0% 89.0% 89.0% TUV Rheinland Product Safety
R&N 150mV 150mV 150mV 150mV 150mV 150mV 200mV
PS E
Effi. 83.0% 85.0% 88.5% 88.5% 88.0% 88.0% 88.5%
11
40~80W Single Output with PFC Features •2Universal AC input (up to 305VAC) / Full range
• Suitable for dry, damp location
•2Fully isolated plastic case with IP64 level
• Suitable for LED lighting and moving sign applications
• Built-in active PFC function, PF> 0.9 for 60% of load or higher
• Multiple models for choice: A-Type: IP64 rated. Output voltage and constant current level
• Protections:
can be adjusted through internal potentiometer
Short circuit / Over current / Over voltage / Over temperature
B-Type: IP64 rated and built-in 3 in 1 dimming function
• Built-in constant current limiting circuit (C.V.+C.C. mode)
(1-10VDC, PWM signal, or resistance)
• Class 2 power unit / Pass LPS
• 3 years warranty
• High efficiency up to 91% • Cooling by free air convection
HLN-40H
HLN-60H
HLN-80H
INPUT
B
A
B
A OUTPUT
AC input voltage range
90~305VAC; 127~431VDC
AC inrush current (max.)
Cold start, 50A at 230VAC
DC adjustment range
±10% rated output voltage (A-Type only)
Current adjustment range
60%~100%
Over current protection
95%~108% constant current limiting, auto-recovery
Over voltage protection
109%~150% rated output voltage
Setup, rise, hold up time
1000ms, 80ms, 16ms at full load and 230VAC
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC
Working temperature
-40~+50 O C (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; Design refer to UL/EN60950-1, EN60335-1for HLN-40H/60H
EMC standards
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection
Cold start, 55A at 230VAC
Input
UL rated, SVT 18AWGx3C (30cm)
Output
A-Type: UL rated, SVT 18AWGx2C (30cm) ; B-Type: UL rated, SVT 18AWGx4C (30cm)
Dimension (LxWxH) (mm)
HLN-40H Series Model No.
161x 61.5x 35
(for 48~54V)
Output
(for 12~42V)
Tol.
181x 61.5x 35
TUV Rheinland Product Safety
PS E
R&N
Model No.
Output
Tol.
R&N
Effi.
Effi.
HLN-60H-36 A
36V, 0~1.70A
±1.0%
200mV
90.0%
HLN-40H-12 A
12V, 0~3.33A
±2.5%
150mV
86.5%
HLN-60H-42 A
42V, 0~1.45A
±1.0%
300mV
90.0%
HLN-40H-15 A
15V, 0~2.67A
±2.0%
150mV
86.5%
HLN-60H-48 A
48V, 0~1.30A
±1.0%
300mV
90.5%
HLN-40H-20 A
20V, 0~2.00A
±1.0%
150mV
87.5%
HLN-60H-54 A
54V, 0~1.15A
±1.0%
300mV
90.5%
HLN-40H-24 A
24V, 0~1.67A
±1.0%
150mV
88.0%
= A or B
HLN-40H-30 A
30V, 0~1.34A
±1.0%
200mV
88.5%
HLN-40H-36 A
36V, 0~1.12A
±1.0%
200mV
88.5%
HLN-40H-42 A
42V, 0~0.96A
±1.0%
300mV
88.5%
Model No.
Output
Tol.
R&N
Effi.
HLN-40H-48 A
48V, 0~0.84A
±1.0%
300mV
89.0%
HLN-80H-12 A
12V, 0~5.0A
±2.5%
150mV
88.0%
HLN-40H-54 A
54V, 0~0.75A
±1.0%
300mV
89.0%
HLN-80H-15 A
15V, 0~5.0A
±2.0%
150mV
89.0%
HLN-80H-20 A
20V, 0~4.0A
±1.0%
150mV
90.0%
HLN-80H-24 A
24V, 0~3.4A
±1.0%
150mV
90.5%
HLN-80H-30 A
30V, 0~2.7A
±1.0%
200mV
91.0%
HLN-80H-36 A
36V, 0~2.3A
±1.0%
200mV
91.0%
HLN-80H-42 A
42V, 0~1.95A
±1.0%
200mV
91.0%
HLN-80H-48 A
48V, 0~1.7A
±1.0%
200mV
91.0%
HLN-80H-54 A
54V, 0~1.5A
±1.0%
200mV
91.0%
= A or B
HLN-60H Series
12
(for 48~54V)
(for 15~42V)
TUV Rheinland Product Safety
R&N
PS E
Model No.
Output
Tol.
Effi.
HLN-60H-15 A
15V, 0~4.0A
±2.0%
150mV
87.0%
HLN-60H-20 A
20V, 0~3.0A
±1.0%
150mV
88.5%
HLN-60H-24 A
24V, 0~2.5A
±1.0%
150mV
89.0%
HLN-60H-30 A
30V, 0~2.0A
±1.0%
200mV
89.5%
HLN-80H Series
= A or B
(for 48~54V)
(for 12~42V)
TUV Rheinland Product Safety
PS E
40~60W Multiple-Stage Output Current LED Power Supply Features
LCM-40(DA) / 60(DA)
NE W
•2Output current level selectable by DIP switch •2180~295VAC input only •2Built-in active PFC function •2Protections: Short circuit / Over voltage / Over temperature •2Cooling by free air convection • Fully isolated plastic case • Class II power unit, no F.G. • IP20 design • Built-in 0~10Vdc and PWM signal dimming function (LCM-40/60) • Built-in DALI interface and push dimming function (LCM-40DA/60DA) • Built-in 12V/50mA auxiliary output • Temperature compensation function by external NTC • No load power consumption <1W (LCM-40/60) No load power consumption <1.2W (LCM-40DA/60DA) • Power supplies synchronization function up to 10 units • Suitable for indoor LED lighting applications • 3 years warranty
AC input voltage range
180~295VAC; 254~417VDC
AC inrush current (Typ.)
Cold start, 20A at 230VAC
Short circuit protection
Constant current limiting, recovers automatically after fault condition is removed
Over voltage protection
LCM-40/40DA: 110~130VDC, LCM-60/60DA: 105~125VDC
Over temp. protection
Range
O O 90 C ±10 C (RTH2)
Type
Shut down o/p voltage, re-power on to recover
Setup, rise, hold up time
1000ms, 80ms, 16ms at full load and 230VAC
Withstand voltage
I/P-O/P: 3.75kVAC
Working temperature
O -30~+60 C (refer to output derating curve)
Safety standards
UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 approved
DALI standards
Comply with IEC62386-101, 102, 207 (LCM-40DA/60DA only)
EMC standards
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Dimension (LxWxH)(mm)
123.5x 81.5x 23
LCM-40(DA) Series O u tpu t
Io T ol.
R&N
Effi.
DI P S wi tc h 3 4
1
2
5
6
350mA , 2 ~ 1 0 0 V
-----
-----
-----
-----
-----
-----
500mA , 2 ~ 8 0 V
ON
-----
-----
-----
-----
-----
600mA , 2 ~ 6 7 V
ON
ON
-----
-----
-----
-----
ON
ON
ON
-----
-----
ON
900mA , 2 ~ 4 5 V
ON
ON
ON
ON
-----
ON
1050m A , 2 ~ 4 0 V
ON
ON
ON
ON
ON
ON
1
2
5
6
500mA , 2 ~ 9 0 V
-----
-----
-----
-----
-----
-----
600mA , 2 ~ 9 0 V
ON
-----
-----
-----
-----
-----
ON
ON
-----
-----
-----
-----
ON
ON
ON
-----
-----
ON
1050m A , 2 ~ 5 7 V
ON
ON
ON
ON
-----
ON
1400m A , 2 ~ 4 2 V
ON
ON
ON
ON
ON
ON
7 0 0 mA, 2~57V (Factory setting)
±5%
700mV
90.5%
LCM-60(DA) Series O u tpu t
7 0 0 mA, 2~86V (Factory setting) 900mA , 2 ~ 6 7 V
Io T ol.
±5%
R&N
700mV
Effi.
91.5%
DI P S wi tc h 3 4
► LCM- 40/6 0 are pri ma r y mod e ls w it h 0 ~ 1 0 V d c a n d P W M s i g n a l di m m i n g f u n c ti o n . ► LCM- 40DA /60DA ha v e D ALI int e r fa ce a nd p us h di m m i n g f u n c ti o n . 13
20~ 60W Single O u t pu t wit h PFC Features • Universal AC input / Full range
• Class 2 power unit / Pass LPS
• Protections: Short circuit / Over current / Over voltage /
• Isolation class II, no F.G. for PLP-20 • Built-in constant current limiting circuit (C.V.+C.C. mode)
Over temperature (PLP-20 only) • Built-in active PFC function, PF>0.9 for 75% of load or higher
• Suitable for building in LED lighting systems
• Cooling by free air convection
• 2 years warranty
PLP-30
PLP-20
AC input voltage range
90~277VAC; 127~392VDC
AC inrush current (max.)
Cold start, 25A at 230VAC
Current adjustable range
75%~100%
Over current Range protection Type
95%~110%
PLP-45/60
90~264VAC; 127~370VDC PLP-45: Cold start, 30A at 230VAC PLP-60: Cold start, 35A at 230VAC
100%~110%
Constant current limiting, auto-recovery
Setup, rise, hold up time
2300ms, 200ms at full load and 230VAC, no hold up time
1200ms(setup time) at full load and 230VAC, no hold up time
Withstand voltage
I/P-O/P: 3.75kVAC
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC
Working temperature
O -30~+60 C
-30~+70OC (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13 approved
EMC standards
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection
UL1015 18AWGx2C (30cm)
3+2P / 3.96mm pitch, JST P/N: B3P / B2P-VH
Dimension (LxWxH)(mm)
140x 32x 22
101.6x 50.8x 26.6
PLP-20 Series
1000ms(setup time) at full load and 230VAC, no hold up time
101.6x 50.8x 29.6
PLP-45 Series
(for 48V only)
(for 12/24V)
Mod el N o .
O u t put
Tol .
R& N
E ffi.
Model No.
Ou tpu t
Tol.
R&N
E f f i.
PLP- 2 0 -1 2
1 2 V , 0 ~1. 6A
±10%
2. 5V
80.0 %
P LP - 4 5- 12
12V , 0~3.8 A
±10%
4.2 V
86%
PLP- 2 0-1 8
1 8 V , 0~1. 1A
±10%
3. 0V
81.0 %
P LP - 4 5- 24
2 4V , 0~1.9 A
± 10%
3.8 V
89%
PLP- 2 0-2 4
2 4 V , 0~0. 8A
±10%
3. 0V
82.0 %
P LP - 45- 48
48V , 0~0.9 5A
± 10%
4.8 V
89%
PLP- 2 0-3 6
3 6 V , 0~0. 55A
±10%
3. 0V
83.0 %
PLP- 2 0-4 8
4 8 V , 0 ~0. 42A
±10%
3. 8V
83.5 %
PLP-30 Series
(for 48V only)
PLP-60 Series
(for 12/24V)
(for 48V only)
(for 12/24V)
Mod el N o .
O u t put
Tol .
R& N
Effi.
Model No.
Ou tpu t
T ol.
R&N
E f f i.
PLP- 3 0-1 2
1 2 V , 0 ~2. 5A
±10%
2. 0V
83.0 %
P LP - 60- 12
12V , 0~5.0 A
± 10%
4 .5 V
84%
PLP- 3 0-2 4
2 4 V , 0 ~1. 3A
±10%
2. 4V
85.5 %
P LP - 60- 24
24V , 0~2.5 A
± 10%
4 .5 V
88%
PLP- 3 0-4 8
4 8 V , 0 ~ 0. 63A
±10%
4. 8V
86.5 %
P LP - 60- 48
4 8V , 0~1.3 A
± 10%
4 .8 V
89%
► ►Special Symbols for EN61347-2-13 Protection against overheating to prevent the lamp controlgear case temperature under any conditions of use from exceeding the indicated value (110 C)
110
O
F M
Suitable for direct mounting on normally flammable surfaces, such as wood (>2mm) M
LPS
Based on VDE0710-14, can be installed inside a wooden material like wooden cabinet. The minimum distance between the product enclosure to wooden material in each side is defined. Limited power source
o
14
tc: 80 C o ta: 40 C
Full load operation up to 40 C with surface temperature of case < 80 OC
SELV
Vo< 120VDC can have this mark on the unit
O
40~ 80W Single O u t pu t wit h PFC Features •2Universal AC input (up to 305VAC) / Full range
• C lass 2 power unit / Pass LPS
• P rotections:
• C ooling by free air convection • S uitable for built-in LED lighting system
Short circuit / Over current / Over voltage / Over temperature
• B uilt-in 3 in 1 dimming function
• B uilt-in active PFC, PF>0.95
(1~10VDC, PWM signal, or resistance)
• O utput constant current level adjustable
• 3 years warranty
• B uilt-in constant current limiting circuit (C.V.+C.C. mode)
HLP-40H
HLP-60H
HLP-80H
AC input voltage range
90~305VAC ; 127~431VDC
AC inrush current (max.)
Cold start, 50A at 230VAC
DC adjustment range
±10% rated output voltage
Current adjustment range
60%~100%
Over current protection
95%~108% constant current limiting, auto-recovery
Over voltage protection
109%~145% rated output voltage
Setup, rise, hold up time
1000ms, 80ms, 16ms at full load and 230VAC
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC
Working temperature
-40~+70 O C (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13 approved; Design refer to EN60335-1(HLP-40H/60H), UL60950-1, EN60950-1
80%~100%
1000ms, 200ms, 16ms at full load and 230VAC
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
EMC standards Connection
Cold start, 55A at 230VAC
Input Output
Dimension (LxWxH) (mm)
6+6P/3.96mm pitch, JST P/N: B6P-VH 147x 53x 27
HLP-40H Series
(for 48V/54V)
167x 53x 29.5
(for 12~42V)
Model No.
Output
Tol.
HLP-40H-12
12V, 0~3.33A
±2.5%
150mV
87.0%
HLP-60H-36
HLP-40H-15
15V, 0~2.67A
±2.0%
150mV
87.0%
HLP-60H-42
HLP-40H-20
20V, 0~2.00A
±1.0%
150mV
88.0%
HLP-60H-48
HLP-40H-24
24V, 0~1.67A
±1.0%
150mV
88.0%
HLP-60H-54
HLP-40H-30
30V, 0~1.34A
±1.0%
200mV
88.5%
HLP-40H-36
36V, 0~1.12A
±1.0%
200mV
89.0%
HLP-40H-42
42V, 0~0.96A
±1.0%
300mV
89.0%
HLP-40H-48
48V, 0~0.84A
±1.0%
300mV
89.5%
HLP-40H-54
54V, 0~0.75A
±1.0%
300mV
89.5%
HLP-60H Series
(for 48V/54V)
R&N
Effi.
(for 12~42V)
Model No.
Output
Tol.
R&N
Effi.
36V, 0~1.70A
±1.0%
200mV
90.0%
42V, 0~1.45A
±1.0%
300mV
90.0%
48V, 0~1.30A
±1.0%
300mV
90.5%
54V, 0~1.15A
±1.0%
300mV
90.5%
HLP-80H Series Model No.
(for 48V/54V)
(for 12~42V)
Output
Tol.
R&N
Effi.
HLP-80H-12
12V, 0~5.0A
±2.5%
150mV
87.5%
HLP-80H-15
15V, 0~5.0A
±2.0%
150mV
88.5%
HLP-80H-20
20V, 0~4.0A
±1.0%
150mV
89.5%
HLP-80H-24
24V, 0~3.4A
±1.0%
150mV
90.0%
Model No.
Output
Tol.
Effi.
HLP-80H-30
30V, 0~2.7A
±1.0%
200mV
90.0%
HLP-60H-15
15V, 0~4.0A
±2.0%
150mV
88.0%
HLP-80H-36
36V, 0~2.3A
±1.0%
200mV
90.0%
HLP-60H-20
20V, 0~3.0A
±1.0%
150mV
89.0%
HLP-80H-42
42V, 0~1.95A
±1.0%
200mV
90.0%
HLP-60H-24
24V, 0~2.5A
±1.0%
150mV
89.5%
HLP-80H-48
48V, 0~1.7A
±1.0%
200mV
90.0%
HLP-60H-30
30V, 0~2.0A
±1.0%
200mV
90.0%
HLP-80H-54
54V, 0~1.5A
±1.0%
200mV
90.0%
R&N
15
60~96W Single Output with PFC Features •2Universal AC input (up to 295VAC) / Full range •2P rotections: Short circuit / Over current / Over voltage / Over temperature •2Built-in active PFC function, PF>0.9 for 75% of load or higher •2IP66 design •2Meet 4kV surge immunity level (IEC61000-4-5)
•2Class 2 power unit / Pass LPS •2Cooling by free air convection •2Suitable for dry, damp, and wet location •2Suitable for LED lighting and moving sign applications •23 years warranty
CEN-60/75
CEN-100
INPUT
OUTPUT
AC input voltage range
90~295VAC ; 127~417VDC
AC inrush current (max.)
Cold start, 45A at 230VAC
DC adjustment range
±10% rated output voltage
Current adjustment range
75%~100%
Over current protection
95%~110% constant current limiting, auto-recovery
Over voltage protection
110%~140% rated output voltage (RTH1) shut down o/p voltage, 85 re-power on to recover
100oC ±10oC (RTH1) shut down o/p voltage, re-power on to recover
Setup time
1400ms at full load and 230VAC, no hold up time
3000ms at full load and 230VAC, no hold up time
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC
Working temperature
-30~+70OC (refer to output derating curve)
Safety standards
UL8750, UL879 (except for CEN-100), TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved
Connection
±10oC
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Input
UL rated, SJTW 18AWGx3C (30cm)
Output
UL rated, SVT 18AWGx2C (30cm)
Dimension (LxWxH) (mm)
185x 62.5x 40.5
CEN-60 Series Model No.
195x 62.5x 40.5
TUV Rheinland Product Safety
Output
Tol.
PS E
R&N
Effi.
Model No.
Output
Tol.
R&N
Effi.
30V, 0~2.50A
±10%
3.0V
90% 90%
CEN-60-12
12V, 0~5.0A
±10%
2.0V
86%
CEN-75-30
CEN-60-15
15V, 0~4.0A
±10%
2.4V
87%
CEN-75-36
36V, 0~2.10A
±10%
3.6V
CEN-60-20
20V, 0~3.0A
±10%
1.8V
88%
CEN-75-42
42V, 0~1.80A
±10%
4.0V
90%
CEN-60-24
24V, 0~2.5A
±10%
2.4V
89%
CEN-75-48
48V, 0~1.57A
±10%
4.6V
91%
CEN-60-30
30V, 0~2.0A
±10%
3.0V
90%
CEN-75-54
54V, 0~1.40A
±10%
5.0V
91%
CEN-60-36
36V, 0~1.7A
±10%
3.6V
90%
CEN-60-42
42V, 0~1.45A
±10%
4.0V
90%
CEN-60-48
48V, 0~1.3A
±10%
4.6V
91%
CEN-60-54
54V, 0~1.15A
±10%
5.0V
91%
CEN-75 Series
16
110%~135% rated output voltage
Over temp. protection
EMC standards
oC
65%~100%
TUV Rheinland Product Safety
PS E
CEN-100 Series
(for 48V/54V)
(for 20~42V)
TUV Rheinland Product Safety
PS E
Model No.
Output
Tol.
R&N
Effi.
CEN-100-20
20V, 0~4.80A
±10%
2.0V
88%
CEN-100-24
24V, 0~4.00A
±10%
2.7V
89%
CEN-100-30
30V, 0~3.20A
±10%
3.0V
90%
Model No.
Output
Tol.
R&N
Effi.
CEN-100-36
36V, 0~2.65A
±10%
3.6V
90%
CEN-75-15
15V, 0~5.00A
±10%
2.7V
87%
CEN-100-42
42V, 0~2.28A
±10%
4.0V
90%
CEN-75-20
20V, 0~3.75A
±10%
2.0V
88%
CEN-100-48
48V, 0~2.00A
±10%
4.6V
91%
CEN-75-24
24V, 0~3.15A
±10%
2.7V
89%
CEN-100-54
54V, 0~1.77A
±10%
5.0V
91%
60~150W Single Output with PFC Features
•2Universal AC input (up to 295VAC) / Full range •2Protections: Short circuit / Over current / Over voltage / Over temperature •2Built-in active PFC function, PF>0.9 for 75% of load or higher •2IP67/IP65 design for indoor or outdoor installations (except for C-Type) •2Output current adjustable through output cable or internal potentiometer (CLG-150) •2Class 2 power unit / Pass LPS (CLG-60&100) •2Cooling by free air convection • Suitable for LED lighting, street lighting and moving sign applications
C LG - 6 0
• Built-in constant current limiting circuit (C.V.+C.C. mode) •2Meet 4kV surge immunity level (IEC 61000-4-5) • Multiple models for CLG-150 : A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated. Constant current level adjustable through output cable C-Type: Non IP. Terminal block for I/O connection Blank-Type: IP67 rated. Cable for I/O connection • 3 years warranty
C L G-1 0 0
C L G-1 5 0
INPUT
B
A
C
Blank
OUTPUT Class 2
AC input voltage range AC inrush current (max.) DC adjustment range Current adjustment range Over current protection Over voltage protection Setup, rise, hold up time Withstand voltage Working temperature Safety standards EMC standards Input Connection
Output
Dimension (LxWxH)(mm) Packing
Class 2
90~295VAC; 127~417VDC Cold start, 65A at 230VAC Fixed. Can be modified between 90%~110% (CLG-60) Can be adjusted between 85%~110% by internal potentiometer (A and C-Type) or 85%~100% (CLG-100) rated output voltage Fixed. Can be modified between 75%~103% Can be adjusted between 50%~100% by internal potentiometer rated output current (A and C-Type) or through output cable (B-Type) 95%~110% constant 95%~102% constant 95%~108% constant current limiting, auto-recovery current, auto-recovery current, auto-recovery 110%~140% rated output voltage 110%~145% rated output voltage 3000ms(setup time), 1200ms, 80ms, 60ms 3000ms, 80ms, 50ms at full load and 230VAC at full load and 230VAC no hold up time I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC -30~+70OC (refer to output derating curve) UL1310, UL8750, UL879, TUV EN61347-1, UL60950-1, UL1012, UL8750, TUV EN60950-1, EN61347-2-13, PSE J61347-1, EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13(option) approved; J61347-2-13(option, except for CLG-150 C-Type) TUV EN60950-1 for CLG-100 only approved EN55015, EN55022 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 UL rated, SJTW 18AWGx3C (30cm); Terminal block for C type UL rated, SJTW 18AWGx3C (30cm) A & Blank-Type : SJTW 14AWGx2C (30cm) UL rated, SVT 18AWGx2C (30cm) B-Type: SJTW 14AWGx2C (30cm)+18AWGx2C (30cm) C-Type: Terminal block 195.6x 61.5x 38.8 222.2x 68x 38.8 A/B/Blank-Type: 222.2x 68x 38.8; C-Type: 229x 68x 38.8 0.86kg ; 16pcs / 14.8kg 1.0kg ; 12pcs / 13kg 1.0kg ; 12pcs / 13kg Cold start, 35A at 230VAC Cold start, 40A at 230VAC
CLG-60 Series
(option)
(for 48V only) (for 12~36V)
Model No.
Output
Tol.
R&N
Effi.
CLG-60-12
12V, 0~5.0A
±10%
2.0V
85.0%
CLG-60-15
15V, 0~4.0A
±10%
2.4V
86.0%
CLG-60-20
20V, 0~3.0A
±10%
1.8V
87.5%
CLG-60-24
24V, 0~2.5A
±10%
2.7V
87.0%
CLG-60-27
27V, 0~2.3A
±10%
2.7V
88.0%
CLG-60-36
36V, 0~1.7A
±10%
3.6V
89.0%
CLG-60-48
48V, 0~1.3A
±10%
4.6V
89.0%
CLG-100 Series
(option)
(for 48V only) (for 12~36V)
Model No.
Output
Tol.
R&N
Effi.
CLG-100-12
12V, 0~5.00A
±3%
150mV
83.0%
CLG-100-15
15V, 0~5.00A
±3%
150mV
85.0%
CLG-100-20
20V, 0~4.80A
±3%
150mV
88.5%
CLG-100-24
24V, 0~4.00A
±3%
150mV
88.5%
Model No.
Output
Tol.
R&N
Effi.
CLG-100-27
27V, 0~3.55A
±3%
150mV
88.0%
CLG-100-36
36V, 0~2.65A
±2%
150mV
88.0%
CLG-100-48
48V, 0~2.00A
±2%
200mV
88.5%
CLG-150 Series
(option)
Model No.
Output
Tol.
R&N
Effi.
CLG-150-12 A
12V, 0~11.0A
±2%
150mV
88%
CLG-150-15 A
15V, 0~9.50A
±2%
150mV
88%
CLG-150-20 A
20V, 0~7.50A
±2%
150mV
90%
CLG-150-24 A
24V, 0~6.30A
±1%
150mV
90%
CLG-150-30 A
30V, 0~5.00A
±1%
150mV
91%
CLG-150-36 A
36V, 0~4.20A
±1%
150mV
91%
CLG-150-48 A
48V, 0~3.20A
±1%
200mV
91%
□= A, B, C or blank
CLG-60-12/24/48, CLG-100-12/24/48 & CLG-150-12A/24A/36A/ 48A are our popular models. We will keep sufficient stock for prompt delivery of high quantity orders.
17
40~60W High Efficiency with PFC Features •2Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC, PF>0.9 for 60% of load or higher • High efficiency up to 90.5% • IP67 / IP65 design for indoor or outdoor installations • Output current adjustable through output cable or internal potentiometer • Cooling by free air convection • Suitable for dry, damp, and wet location • Suitable for LED lighting and street lighting applications
• Meet 4kV surge immunity level (IEC61000-4-5) • Class 2 power unit • Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details. • 5 years warranty
HLG-40H
HLG-60H A
INPUT
B
Blank/D
OUTPUT
90~305VAC ; 127~431VDC
AC input voltage range AC inrush current (max.)
Cold start, 50A at 230VAC
DC adjustment range
±10% rated output voltage (A-Type only)
Current adjustment range
60%~100%
Over current protection
95%~108% constant current limiting, auto-recovery
Over voltage protection
109%~145% rated output voltage
Setup, rise, hold up time
1000ms, 80ms, 16ms at full load and 230VAC
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC
Working temperature
-40~+70OC (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; Design refer to UL60950-1, EN60950-1, EN60335-1 EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
EMC standards Connection
Cold start, 55A at 230VAC
Input
UL rated, SJTW 18AWGx3C (30cm)
Output
A/D/Blank-Type: SVT 18AWGx2C (30cm); B-Type: SVT 18AWGx2C (30cm)+UL2517 18AWGx2C (30cm)
Dimension (LxWxH) (mm)
HLG-40H Series
(for 48V/54V)
Model No.
HLG-40H-12 A HLG-40H-15 A
171x 61.5x 36.8
Output
12V, 0~3.33A 15V, 0~2.67A
Model No.
(for 12~42V)
Tol.
±2.5% ±2.0%
R&N
150mV 150mV
Output
Tol.
R&N
Effi.
Effi.
HLG-60H-36 A
36V, 0~1.70A
±1.0%
200mV
90.0%
86.5%
HLG-60H-42 A
42V, 0~1.45A
±1.0%
300mV
90.0%
86.5%
HLG-60H-48 A
48V, 0~1.30A
±1.0%
300mV
90.5%
HLG-60H-54 A
54V, 0~1.15A
±1.0%
300mV
90.5%
HLG-40H-20 A
20V, 0~2.00A
±1.0%
150mV
88.0%
HLG-40H-24 A
24V, 0~1.67A
±1.0%
200mV
88.0%
HLG-40H-30 A
30V, 0~1.34A
±1.0%
200mV
88.5%
HLG-40H-36 A
36V, 0~1.12A
±1.0%
200mV
88.5%
HLG-40H-42 A
42V, 0~0.96A
±1.0%
200mV
88.5%
HLG-40H-48 A
48V, 0~0.84A
±1.0%
300mV
89.5%
HLG-40H-54 A
54V, 0~0.75A
±1.0%
300mV
89.5%
= A, B, D or Blank
► ►Junction Box for HLG Series
= A, B, D or Blank
HLG-60H Series
18
(for 48V/54V)
(for 15~42V)
Model No.
Output
Tol.
R&N
Effi.
HLG-60H-15 A
15V, 0~4.0A
±2.0%
150mV
87.5%
HLG-60H-20 A
20V, 0~3.0A
±1.0%
150mV
89.0%
HLG-60H-24 A
24V, 0~2.5A
±1.0%
150mV
89.5%
HLG-60H-30 A
30V, 0~2.0A
±1.0%
200mV
90.0%
• Optional junction box available for HLG-80H~320H series (A/B/Blank-Type only). Please contact MEAN WELL for details. • “UL8750 listed” safety & IP66 approved for HLG-80H- BL (modified by B-Type only)
80~120W High Efficiency with PFC Features •2Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC, PF>0.9 for 60% of load or higher • High efficiency up to 93.5% • IP67 / IP65 design for indoor or outdoor installations • Output current adjustable through output cable or internal potentiometer • Cooling by free air convection • Suitable for dry, damp, and wet location • Suitable for LED lighting and street lighting applications • Meet 4kV surge immunity level (IEC61000-4-5) • Class 2 power unit / Pass LPS (except for HLG-120H)
• Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection BL-Type(option): for HLG-80H B-Type only, "UL8750 listed" safety & IP66 approved, contact MEAN WELL for details D-Type(option): IP67 rated. Timer dimming function, contact MEAN WELL for details • Optional CQC models available (HLG-100H/120H-A/Blank type) • 5 years warranty
HLG-100H / HLG-120H
HLG-80H INPUT
A
B
Blank/D
OUTPUT
90~305VAC ; 127~431VDC
AC input voltage range AC inrush current (max.)
Cold start, 55A at 230VAC
DC adjustment range
±10% rated output voltage (A-Type only)
Current adjustment range
HLG-80H/100H: 60%~100% ; HLG-120H: 50%~100%
Over current protection
95%~108% constant current limiting, auto-recovery
Over voltage protection
110%~140% rated output voltage
Setup, rise, hold up time
1000ms, 80ms, 16ms at full load and 230VAC
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG:0.5kVAC
Working temperature
-40~+70 O C (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; UL8750 listed for HLG-80H- □ BL only; Design refer to UL60950-1, EN60950-1
EMC standards
EN55015, EN55022 class B (except for HLG-80H), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection
Cold start, 60A at 230VAC
2500ms, 50ms, 16ms at full load and 230VAC
Input
UL rated, SJTW 18AWGx3C (30cm)
Output
A/D/Blank-Type: SVT 18AWGx2C (30cm) ;
A/D/Blank-Type: SJTW 14AWGx2C (30cm) ;
195.6x 61.5x 38.8
220x 68x 38.8
B-Type: SVT 18AWGx2C (30cm)+UL2517 18AWGx2C (30cm)
Dimension (LxWxH) (mm)
B-Type: SJTW 14AWGx2C (30cm)+SJTW 18AWGx2C (30cm)
Model No.
HLG-80H Series Model No.
HLG-80H-12 HLG-80H-15 HLG-80H-20 HLG-80H-24 HLG-80H-30 HLG-80H-36 HLG-80H-42 HLG-80H-48 HLG-80H-54
(for 48V/54V)
Output
A A A A A A A A A
12V, 0~5.0A 15V, 0~5.0A 20V, 0~4.0A 24V, 0~3.4A 30V, 0~2.7A 36V, 0~2.3A 42V, 0~1.95A 48V, 0~1.7A 54V, 0~1.5A
R&N
Effi.
(for 12~42BL)
HLG-100H-42 A
42V, 0~2.28A
±1.0%
200mV
93%
R&N
Effi.
HLG-100H-48 A
48V, 0~2.0A
±1.0%
200mV
93%
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV
88.0% 89.0% 90.0% 90.5% 91.0% 91.0% 91.0% 91.0% 91.0%
HLG-100H-54 A
54V, 0~1.77A
±1.0%
200mV
93%
(for 12~42V)
(for 48/54BL)
HLG-100H Series Output
Tol.
Tol.
= A , B, BL, D or Blank
Model No.
Output
Tol.
R&N
= A , B, D or Blank
HLG-120H Series Model No.
Output
Tol.
HLG-120H-12 A
12V, 0~10A
±2.5%
R&N
150mV
Effi.
92.0%
HLG-120H-15 A
15V, 0~8.0A
±2.0%
150mV
92.0%
HLG-120H-20 A
20V, 0~6.0A
±1.0%
150mV
93.0%
HLG-120H-24 A
24V, 0~5.0A
±1.0%
150mV
93.0%
HLG-120H-30 A
30V, 0~4.0A
±1.0%
200mV
93.0%
HLG-120H-36 A
36V, 0~3.4A
±1.0%
200mV
93.0%
Effi.
HLG-120H-42 A
42V, 0~2.9A
±1.0%
200mV
93.0%
HLG-120H-48 A
48V, 0~2.5A
±1.0%
200mV
93.5%
HLG-120H-54 A
54V, 0~2.3A
±1.0%
200mV
93.5%
HLG-100H-20 A
20V, 0~4.8A
±1.0%
150mV
93%
HLG-100H-24 A
24V, 0~4.0A
±1.0%
150mV
93%
HLG-100H-30 A
30V, 0~3.2A
±1.0%
200mV
93%
HLG-100H-36 A
36V, 0~2.65A
±1.0%
200mV
93%
= A , B, D or Blank HLG-120H-12A/24A/48A are our popular models. We will keep sufficient stock for prompt delivery of high quantity orders. 19
150~320W High Efficiency with PFC Features • Universal AC input (up to 305VAC) / Full range • Protections: Short circuit / Over current / Over voltage / Over temp. • Built-in active PFC, PF>0.9 for 60% of load or higher • High efficiency up to 95% • IP67 / IP65 design for indoor or outdoor installations (except for C-Type) • Output current adjustable • Cooling by free air convection • Suitable for LED lighting and street lighting applications • Meet 4kV surge immunity level (IEC61000-4-5)
• Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) C-Type: Terminal block for I/O connection (HLG-240H/320H) Blank-Type: IP67 rated. Cable for I/O connection D-Type(option): I P67 rated. Timer dimming function, contact MEAN WELL for details • Optional CQC models available (HLG-150H/185H/240H-A/Blank-Type) • 5 years warranty
HLG-150H/185H
HL G-2 4 0 H
HL G-3 2 0 H
INPUT
A
B
C
Blank/D
OUTPUT (HLG-240H/320H)
AC input voltage range AC inrush current (max.) DC adjustment range Current adjustment range Over current protection Over voltage protection Setup, rise, hold up time Withstand voltage Working temperature
90~305VAC; 127~431VDC Cold start, 75A at 230VAC Cold start, 70A at 230VAC ±10% rated output voltage ±6% rated output voltage HLG-150H: 60%~100% ; HLG-185H/240H/320H: 50%~100% 95%~108% constant current limiting, auto-recovery 110%~140% rated output voltage 2500ms, 80ms, 16ms 2500ms, 80ms, 15ms at full load and 230VAC I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC -40~+70 O C (refer to output derating curve) Cold start, 65A at 230VAC
UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 (except for C-Type) approved; UL1012, UL60950-1, TUV EN60950-1 approved for HLG-240H only
Safety standards EMC standards Input Connection
Output
Dimension (LxWxH)(mm)
EN55015, EN55022 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 UL rated, SJTW 18AWGx3C (30cm); Terminal block for C-Type (HLG-240H/320H only) A & Blank-Type: SJTW 14AWGx2C (30cm) ; B-Type: SJTW 14AWGx2C (30cm)+SJTW 18AWGx2C (30cm); C-Type: Terminal block (HLG-240H/320H) A/B/D/Blank-Type: A/B/D/Blank-Type: 244.2x 68x 38.8 252x 90x 43.8 228x 68x 38.8 C-Type: 251x 68x 38.8
HLG-240H Series
HLG-150H Series Model No.
HLG-150H-12 HLG-150H-15 HLG-150H-20 HLG-150H-24 HLG-150H-30 HLG-150H-36 HLG-150H-42 HLG-150H-48 HLG-150H-54
A A A A A A A A A
Output
Tol.
R&N
Effi.
12V, 0~12.5A 15V, 0~10.0A 20V, 0~7.50A 24V, 0~6.30A 30V, 0~5.00A 36V, 0~4.20A 42V, 0~3.60A 48V, 0~3.20A 54V, 0~2.80A
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV
91.5% 92.0% 93.0% 93.0% 93.5% 93.5% 94.0% 94.0% 94.0%
= A , B , D or Blank
Output
Tol.
R&N
Effi.
12V, 0~13.0A 15V, 0~11.5A 20V, 0~9.30A 24V, 0~7.80A 30V, 0~6.20A 36V, 0~5.20A 42V, 0~4.40A 48V, 0~3.90A 54V, 0~3.45A
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV
91.5% 92.0% 93.0% 93.5% 93.5% 93.5% 94.0% 94.0% 94.0%
= A , B , D or Blank 20
Output
Tol.
R&N
Effi.
12V, 0~16.0A 15V, 0~15.0A 20V, 0~12.0A 24V, 0~10.0A 30V, 0~8.00A 36V, 0~6.70A 42V, 0~5.72A 48V, 0~5.00A 54V, 0~4.45A
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV
90.0% 90.0% 92.0% 93.0% 93.0% 93.0% 93.0% 93.5% 94.0%
HLG-320H Series
Model No.
A A A A A A A A A
A A A A A A A A A
= A, B , C , D or Blank
HLG-185H Series HLG-185H-12 HLG-185H-15 HLG-185H-20 HLG-185H-24 HLG-185H-30 HLG-185H-36 HLG-185H-42 HLG-185H-48 HLG-185H-54
Model No.
HLG-240H-12 HLG-240H-15 HLG-240H-20 HLG-240H-24 HLG-240H-30 HLG-240H-36 HLG-240H-42 HLG-240H-48 HLG-240H-54
Model No.
HLG-320H-12 HLG-320H-15 HLG-320H-20 HLG-320H-24 HLG-320H-30 HLG-320H-36 HLG-320H-42 HLG-320H-48 HLG-320H-54
A A A A A A A A A
Output
Tol.
R&N
Effi.
12V, 0~22.0A 15V, 0~19.0A 20V, 0~15.0A 24V, 0~13.34A 30V, 0~10.7A 36V, 0~8.90A 42V, 0~7.65A 48V, 0~6.70A 54V, 0~5.95A
±3.0% ±2.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mV 150mV 150mV 150mV 200mV 250mV 250mV 250mV 350mV
91.0% 92.5% 93.5% 94.0% 94.0% 94.5% 95.0% 95.0% 95.0%
= A , B , C , D or Blank
HLG-185H-12A/24A/48A & HLG-240H-12A/24A/48A are our popular models. We will keep sufficient stock for prompt delivery of high quantity orders.
70~ 200 W Co nst ant Cu rrent w i t h PF C Features •2Constant current output with high output voltage>60VDC
• Suitable for LED lighting and street lighting applications
•2Universal AC input (up to 305VAC)/ Full range
•2Multiple models for choice:
•2Built-in active PFC function
A-Type: IP65 rated. Constant current level can be adjusted
•2High efficiency up to 94%
through internal potentiometer
•2Protections: Short circuit / Over voltage / Over temperature
B-Type: IP67 rated and built-in 3 in 1 dimming function
•2Cooling by free air convection
(1~10VDC, PWM signal, or resistance)
•2Output current adjustable through output cable or internal
D-Type (option): IP67 rated. Timer dimming function,
potentiometer
contact MEAN WELL for details
•2IP67 / IP65 design for indoor or outdoor installations
•25 years warranty
• Suitable for dry, damp, and wet location
HLG-60H-C
HLG-80H-C
NE W
INPUT
HLG-120H-C
NE W
HLG-185H-C
De U ve nd lop er me nt
De U ve nd lop er me nt
OUTPUT
AC input voltage range
90~305VAC; 127VDC~431VDC
AC inrush current (Typ.)
Cold start, 60A at 230VAC
Cold start, 70A at 230VAC
Current adjustment range 60%~100%
50%~100%
Short circuit protection
Hiccup mode, auto-recovery
Over temp. protection
85 O C±10 O C(RTH2), shut down o/p voltage, re-power on to recover
Withstand voltage
I/P-O/P:3.75kVAC, I/P-FG:2kVAC, O/P-FG:0.5kVAC
Working temperature
-40~+70 O C (refer to output derating curve)
Safety standards
UL8750, TUV EN61347-1, EN61347-2-13 approved (HLG-120H-C/185H-C pending)
EMC standards
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Connection
Input
UL rated, SJTW 16AWGx3C(30cm)
Output
A&D-Type: SJTW 16AWGx2C(30cm) B-Type: SJTW 16AWGx2C(30cm)+ SJTW 16AWGx2C(30cm)
A&D-Type: STW 16AWGx2C(30cm) B-Type: STW 16AWGx2C(30cm)+ SJTW16AWGx2C(30cm)
171x 61.5x 36.8
220x 68x 38.8
Dimension (LxWxH)(mm)
195.6x 61.5x 38.8
HLG-80H-C Series
HLG-60H-C Series Mod e l N o .
O ut p ut
I o Tol .
R& N
E ffi.
HLG-60H-C350 A
100~200V, 350mA
±5%
1.0V
91.0%
HLG-60H-C700 A
50~100V, 700mA
±5%
0.5V
90.5%
Ou tpu t
Io Tol.
R&N
E f f i.
HLG-80H-C350 A
167~257V, 350mA
±5%
1.0V
91.5%
HLG-80H-C700 A
84~129V, 700mA
±5%
0.5V
91.5%
Model No.
= A, B or D
= A, B or D
HLG-120H-C Series
UL/CUL/TUV/CB/CE pending O ut p ut
I o Tol .
R& N
E ffi.
HLG-120H-C350 A
215~430V, 350mA
±5%
1.0V
93.5%
HLG-120H-C500 A
150~300V, 500mA
±5%
1.0V
93.5%
HLG-120H-C700 A
107~215V, 700mA
Mod e l N o .
228x 68x 38.8
HLG-185H-C Series
UL/CUL/TUV/CB/CE pending Ou tpu t
I o Tol.
R&N
E f f i.
HLG-185H-C500 A
200~400V, 500mA
±5%
1.0V
94%
HLG-185H-C700 A
143~286V, 700mA
±5%
0.5V
94%
Model No.
±5%
0.5V
93.5%
HLG-185H-C1050 A
95~190V, 1050mA
±5%
0.5V
94%
HLG-120H-C1050 A
74~148V, 1050mA
±5%
0.5V
93.5%
HLG-185H-C1400 A
71~143V, 1400mA
±5%
0.5V
94%
HLG-120H-C1400 A
54~108V, 1400mA
±5%
0.5V
93.5%
= A, B or D
= A, B or D 21
96~150W Wide Input Range with PFC Features •2Wide input range: 180~480VAC for HVG(C)-100 180~528VAC for HVG(C)-150 • Protections: Short circuit / Over voltage / Over temperature / Over current (HVG-100/150) • Built-in active PFC • High efficiency up to 91.5% • IP67 / IP65 design • Cooling by free air convection • C.V. +C.C. mode design (HVG-100/150) • Constant current design (HVGC-100/150) • Output current adjustable through output cable or internal potentiometer
• Class 2 power unit / Pass LPS for HVG-100 • Suitable for dry, damp, and wet location • Suitable for LED lighting and street lighting applications • Multiple models for choice: A-Type: IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (0~10VDC, PWM signal, or resistance) D-Type (option): IP67 rated. Timer dimming function, contact MEAN WELL for details • 5 years warranty
HVG/HVGC-100
HVG/HVGC-150
NE W
INPUT
OUTPUT
AC input voltage range AC inrush current (max.) DC adjustment range Current adjustment range Over current protection ( HVG-100/150 ) Over voltage protection Withstand voltage Working temperature Safety standards EMC standards Input
Connection
A&DType Output
BType
Dimension (LxWxH)(mm)
HVG-100 Series
180~480VAC(single phase); 254~679VDC 180~528VAC (single phase); 254~747VDC Cold start, 25A at 440VAC Cold start, 35A at 480VAC ±10% rated output voltage HVG-100/150: 55%~100% ; HVGC-100/150: 60%~100% 95%~108% constant current limiting, auto-recovery 110%~140% rated output voltage I/P-O/P: 3.75kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC -40~+70 OC (refer to output derating curve) HVG-100/150: UL8750 approved HVGC-100/150: UL8750, TUV EN61347-1, EN61347-2-13 approved EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547, FCC part 15 class B UL rated, STW 18AWGx3C (30cm) HVG-100: SVT 18AWGx2C (30cm) HVG-150: SJTW 14AWGx2C (30cm) HVGC-150: STW 18AWGx2C (30cm) HVGC-100: SJTW 18AWGx2C (30cm) HVG-100: SVT 18AWGx2C (30cm)+ UL2517 18AWGx2C (30cm) HVGC-100: SJTW 18AWGx2C(30cm)+ UL2517 18AWGx2C (30cm) 236x 68x 38.8
(C.V. +C.C. mode)
(for 42~54V) (for 15~36V)
Model No.
Output
Tol.
R&N
Effi.
HVG-100-15 A
15V, 0~5.0A
±2.0%
150mV
89.0%
HVG-100-20 A
20V, 0~4.8A
±1.0%
150mV
90.0%
HVG-100-24 A
24V, 0~4.0A
±1.0%
150mV
91.0%
HVG-100-30 A
30V, 0~3.2A
±1.0%
200mV
91.0%
HVG-100-36 A
36V, 0~2.65A
±1.0%
200mV
90.5%
HVG-100-42 A
42V, 0~2.28A
±1.0%
200mV
90.5%
HVG-100-48 A
48V, 0~2.0A
±1.0%
200mV
91.0%
HVG-100-54 A
54V, 0~1.77A
±1.0%
200mV
91.0%
= A , B or D
HVGC-100 Series Model No.
22
HVG-150 Series
(C.V. +C.C. mode)
Model No.
HVG-150-12 HVG-150-15 HVG-150-20 HVG-150-24 HVG-150-30 HVG-150-36 HVG-150-42 HVG-150-48 HVG-150-54
Output
A A A A A A A A A
12V, 15V, 20V, 24V, 30V, 36V, 42V, 48V, 54V,
0~10A 0~10A 0~7.5A 0~6.25A 0~5A 0~4.17A 0~3.58A 0~3.13A 0~2.78A
Tol.
R&N
Effi.
±2.5% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
150mV 150mV 150mV 150mV 200mV 200mV 200mV 200mV 200mV
87.0% 89.0% 90.5% 91.0% 91.0% 91.0% 91.0% 91.5% 91.5%
= A , B or D
HVGC-150 Series
(C.C. mode) Output
Io Tol.
R&N
(C.C. mode)
Effi.
Model No.
Output
Io Tol.
R&N
Effi.
HVGC-150-350 A HVGC-150-500 A HVGC-150-700 A HVGC-150-1050 A HVGC-150-1400 A
42~428V, 350mA 30~300V, 500mA 21~215V, 700mA 15~143V, 1050mA 12~107V, 1400mA
±5% ±5% ±5% ±5% ±5%
2.0V 1.5V 1.0V 0.7V 0.5V
91% 91% 91% 90% 90%
HVGC-100-350 A
29~285V, 350mA
±5%
1V
91%
HVGC-100-700 A
15~142V, 700mA
±5%
0.5V
91%
= A , B or D
HVG-150: S JTW 14AWGx2C (30cm)+ UL2517 18AWGx2C (30cm) HVGC-150: S TW 18AWGx2C (30cm)+ UL2517 18AWGx2C (30cm) 245x 68x 38.8
= A , B or D
70W &150W Single Output with PFC / Surge Protection Device
7 0 W R e c t a n gu l a r Met a l C a se
1 5 0 W U-Brac ket Single Out put w ith PFC
•Universal AC input (up to 305VAC) • Protections: Short circuit / Over current / Over voltage / Over temperature • Built-in active PFC • Output current adjustable through internal potentiometer • IP65 design • Cooling by free air convection • Suitable for LED lighting and moving sign applications • 3 years warranty
127.2x 90x 38.8 mm
•Universal AC input (up to 295VAC) •Built-in active PFC function •High efficiency up to 93% • P rotections: S hort circuit / Overload / Over voltage / Over temperature •Constant voltage design •Cooling by free air convection •U-bracket low profile: 33mm •3 years warranty
215x 67.4x 33 mm
AC input voltage range AC inrush current (max.)
90~295VAC; 127~417VDC Cold start, 65A at 230VAC
Current adjustment range 60%~100%
Overload protection
Over current protection
95%~108% constant current limiting
130%~185% hiccup mode, auto-recovery
Over voltage protection
112%~140% rated output voltage
Over voltage protection
110%~135% rated output voltage
Setup, rise, hold up time
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 1.88kVAC, O/P-FG: 0.5kVAC
2000ms, 100ms, 16ms at full load and 230VAC
Working temperature
-40~+70OC (refer to output derating curve)
Withstand voltage
I/P-O/P: 3.75kVAC, I/P-FG: 1.88kVAC, O/P-FG: 0.5kVAC
Safety standards
Design refer to EN61347-1, EN61347-2-13
Working temperature
EMC standards
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61547, EN61000-4-2,3,4,5,6,8,11
O -30~+70 C (refer to output derating curve)
Safety standards
Design refer to UL8750, EN61347-1, EN61347-2-13
Input
H05RN-F 1.5mm2x2C (30cm)
EMC standards
Output
H05RN-F 1.0mm2x3C (30cm)
EN55015, EN61000-3-2 class C, EN61000-3-3, EN61547, EN61000-4-2,3,4,5,6,8,11
AC input voltage range
Connection
90~305VAC; 127~431VDC
Model No.
Output
Tol.
R&N
Effi.
Model No.
Output
Tol.
R&N
Effi.
HSG-70-12
12V, 0~5.0A
±2.5%
150mV
88%
ULP-150-12
12V, 0~12.5A
±2%
100mV
91.5%
HSG-70-18
18V, 0~4.0A
±2.0%
200mV
89%
ULP-150-15
15V, 0~10.0A
±2%
150mV
91.5%
HSG-70-24
24V, 0~3.0A
±1.0%
200mV
89%
ULP-150-24
24V, 0~6.30A
±2%
150mV
93.0%
HSG-70-36
36V, 0~2.0A
±1.0%
200mV
90%
ULP-150-36
36V, 0~4.20A
±2%
250mV
93.0%
HSG-70-48
48V, 0~1.5A
±1.0%
200mV
90%
ULP-150-48
48V, 0~3.20A
±2%
250mV
93.0%
2 0 k A S u rge Pro t ec t io n D ev ic e Features •U L1449 3rd Edition, Type 2 component assemblies •L ine to Ground & Line to Line protected •P arallel (3 wires) connection style •LED status indicators
90x 70x 50 mm
•IP67 design •Suitable for surge protection of LED drivers
(SPD-20-240P)
Model No.
SPD-20-240P
SPD-20-277P
Operating voltage
240VAC, 50/60Hz
277VAC, 50/60Hz
MCOV (Max. Continuous Operating Voltage)
300VAC
320VAC
VPR (Voltage Protection Rating)
≤1200 (L-FG, N-FG, L-N)
IN (Nominal Discharge Current)
5kA
Max. Surge Current (8/20μs)
20kA
SCCR (Short Circuit Current Rating)
5kA
Response time
<25ns
Operating temperature
-40~+70OC
Safety standard
UL1449 3rd Edition, TUV EN61643-11 approved UL1449 3rd Edition approved L (Black)
Connection
N (White)
FEP 10AWG (15cm)
FG (Green) 23
DC-DC Co nst ant Cu rrent LED Dr i ve r Features •Constant current LED driver •W ide input and output voltage range •High efficiency up to 97% •C omply with EN55015 and FCC part 15 without additional input filter and capacitors •Built-in PWM dimming and remote ON/OFF control •P rotections: Short circuit / Over temperature
•Compact size •O perating temperature range: -40~+85 o C •Cooling by free air convection •Fully enclosed plastic case (UL 94V-0) •Low cost, high reliability •3 years warranty
LDD - H / HW / HS
L D D -L / LW / L S NEW
±3% at 24VDC input; ±4% at 48VDC input for LDD-H/HW; ±5% at 48VDC input for LDD-HS
Output Current Accuracy
NEW
±5% at 24VDC input
Leave open if not used PWM Dimming & ON/OFF Control
Remote ON/OFF
Power ON with dimming: DIM~-Vin>2.5~6VDC or open circuit Power OFF: DIM~-Vin <0.8VDC or short
PWM Frequency
100~1KHz Regulated at rated output current, can be continued, auto-recovery Tj 150o C typically detect on main control IC Shut down, recovers automatically after temperature goes down - 4 0 ~ + 8 5 o C (refer to output derating curve) EN55015, FCC part 15 class B, EN61000-4-2,3,4,6,8, light industry level, criteria A 100o C LDD-H/HW: 31.8x 20.3x 12.2 LDD-L/LW: 22.6x 9.9x 8.9 LDD-HS: 31.8x 20.3x 11.4 LDD-LS: 25.4x 10.5x 9.3
Short circuit Range Type Working temperature EMC standards Operating case temp. (max.) Over temp. protection
Dimension (LxWxH)(mm)
LDD-H Series Model No.
LDD-L Series Input
LDD-300H LDD-350H LDD-500H LDD-600H LDD-700H LDD-1000H
Output
(VDC)
Voltage
9~56 9~56 9~56 9~56 9~56 9~56
2~52 2~52 2~52 2~52 2~52 2~52
(VDC)
Current
Io Tol.
Effi.
Input
LDD-300HW LDD-350HW LDD-500HW LDD-600HW LDD-700HW LDD-1000HW
300 350 500 600 700 1000
±4% ±4% ±4% ±4% ±4% ±4%
97% 97% 97% 97% 97% 97%
24
LDD-300L LDD-350L LDD-500L LDD-600L LDD-700L
Input
Output
(VDC)
Voltage
Current
Io Tol.
Effi.
9~36 9~36 9~36 9~36 9~36
2~32 2~32 2~32 2~32 2~32
300 350 500 600 700
±5% ±5% ±5% ±5% ±5%
95% 95% 95% 95% 95%
(VDC)
(mA)
LDD-LW Series Output
(VDC)
Voltage
Current
Io Tol.
9~56 9~56 9~56 9~56 9~56 9~56
2~52 2~52 2~52 2~52 2~52 2~52
300 350 500 600 700 1000
±4% ±4% ±4% ±4% ±4% ±4%
(VDC)
Effi.
Input
97% 97% 97% 97% 97% 97%
Output
(VDC)
Voltage
Current
Io Tol.
Effi.
LDD-300LW
9~36
2~32
300
±5%
95%
LDD-350LW
9~36
2~32
350
±5%
95%
LDD-500LW
9~36
2~32
500
±5%
95%
LDD-600LW
9~36
2~32
600
±5%
95%
LDD-700LW
9~36
2~32
700
±5%
95%
Current
Io Tol.
Effi.
300 350 500 600 700 style
±5% ±5% ±5% ±5% ±5%
95% 95% 95% 95% 95%
Model No.
(mA)
(VDC)
(mA)
LDD-LS Series
LDD-HS Series Model No.
Model No.
(mA)
LDD-HW Series Model No.
Power ON with dimming: DIM~-Vin>3.5~8VDC or open circuit Power OFF: DIM~-Vin <0.5VDC or short
Input (VDC)
Output Voltage (VDC)
Current
Io Tol.
Effi.
(mA)
LDD-300HS 9~56 2~52 300 LDD-350HS 9~56 2~52 350 LDD-500HS 9~56 2~52 500 LDD-600HS 9~56 2~52 600 LDD-700HS 9~56 2~52 700 LDD-1000HS 9~56 2~52 1000 H: pin style, HW: wire style, HS: SMD style
±5% ±5% ±5% ±5% ±5% ±5%
96% 96% 96% 96% 96% 96%
Model No.
Input (VDC)
Output Voltage (VDC)
LDD-300LS 9~36 2~32 LDD-350LS 9~36 2~32 LDD-500LS 9~36 2~32 LDD-600LS 9~36 2~32 LDD-700LS 9~36 2~32 L: pin style, LW: wire style, LS: SMD
(mA)
96~240W Circular Shape for High Bay Lighting Description HBG series are high performance LED power supplies specially designed for the high/low bay lighting and spot lighting applications. Featuring with circular shape, these new series are easy to be assembled and perfectly fit in with the mechanical structure of high/ low bay lighting fixtures. Fully potted by glue, their aluminum enclosure can be tightly assembled to the heat sink of lighting fixtures and provide excellent heat dissipation ability, which solve the mechanism limits of old style bay lighting systems using slim shape LED power supplies. As long as the temperature on the top of the enclosure can be controlled under 70 o C, the power supply service life could be guaranteed up to 40,000 hours. For more detail information, please visit our website: www.meanwell.com/product/HBG/HBG.html
H B G- 10 0
HBG-1 6 0
HBG-2 4 0
NE W
NE W
DxH: 130x 66.5mm
De U ve nd lop er me nt
DxH: 151.68x 66.5mm
DxH: 191.5x 69mm
Features •Universal AC input (90~305VAC) •Built-in active PFC function •High efficiency up to 93.5% •Protections: Short circuit / Over current / Over voltage / Over temperature •Output current adjustable through internal potentiometer •IP67 / IP65 design for indoor or outdoor installations •Suitable for dry, damp, and wet location
HBG-100 Series
UL/CUL/TUV/CB/CE pending
Model No.
Output
HBG-100-24 A 24V, HBG-100-36 A 36V, HBG-100-48 A 48V, HBG-100-60 A 60V, = A, B, E or Blank
Tol.
0~4.0A 0~2.7A 0~2.0A 0~1.6A
HBG-160 Series
Model No.
Effi.
±1% ±1% ±1% ±1%
HBG-240 Series
UL/CUL/TUV/CB/CE pending Output
Tol.
Effi.
HBG-160-24 A HBG-160-36 A
24V, 0~6.5A 36V, 0~4.4A
±1% ±1%
92.0% 92.0%
► ►Construction of High Bay Light HBG Series
+
Heat Sink
+
Light Source
+
Output
HBG-160-48 A 48V, 0~3.3A HBG-160-60 A 60V, 0~2.6A = A, B, E or Blank
90.5% 91.0% 91.0% 91.5%
Model No.
Ring
•Multiple models for choice: A-Type: IP65 rated. Constant current level can be adjusted through internal potentiometer B-Type: IP67 rated and built-in 3 in 1 dimming function (1~10VDC, PWM signal, or resistance) Blank-Type: IP67 rated. Cable for I/O connection E-Type(option): IP67 rated. Can be mounted on metal frame, contact MEAN WELL for details •5 years warranty Tol.
Effi.
±1% ±1%
93.0% 93.5%
UL/CUL/TUV/CB/CE pending
Model No.
HBG-240-24 A HBG-240-36 A HBG-240-48 A HBG-240-60 A = A, B or Blank
Output
Tol.
Effi.
24V, 0~10A 36V, 0~6.7A 48V, 0~5.0A 60V, 0~4.0A
±1% ±1% ±1% ±1%
92.5% 92.5% 93.0% 93.5%
lampshade
High Bay Light
+
► ►Installations Spot Light
Stage Light
High Bay Light
Chain Type
Hanger Type 25
► ►Female Waterproof Output Connector (Power supply side) P i n C o n f i g u r a t i o n (F e m a l e )
Waterproof Connector
M12
M15
Order No. : M12-02
Order No. : M12-04
Suitable Current : 5A max.
2-pin (5A/PIN)
Suitable Current : 10A max.
4-pin (5A/PIN)
M 2 0 .5
Order No. : M15-02
2-pin (12A/PIN)
Suitable Current : 12A max.
2-pin (20A/PIN)
M 2 0 .8
Order No. : M20.5-02
Order No. : M20.8-02
Suitable Current : 20A max.
Suitable Current : 20A max.
► The output cable can be modified to include different waterproof connectors by MEAN WELL. Minimum order quantity may vary for different models. ► We would suggest you to order the configurations of "M15 connector with length of 20cm / 30cm / 45cm / 60cm / 80cm / 100cm cables" due to its cost effectiveness and fast delivery. Ordering other connector type or cable lengths will have higher cost and longer lead-time. ► Suitable for CLG / HLG / HLG-C / HVG(C) / CEN / HSG / HLN / LPF series.
► ►Male Waterproof Output Connector with Cable (System side) Figure
Drawing
L= 30cm / 60cm / 100cm for choice
► M EAN WELL offers male waterproof connectors with cable length of 30cm, 60cm, and 100cm as our standard mating accessories. These mating accessories need to be ordered together with PSU. For other length or cable style, the higher MOQ requirement and long lead-time will be expected. Please consult MEAN WELL for details.
► ►Order
No.
M12-02M-30-U1-UN 1
2
3
4
5
Cable Type
3
6
Connector Type: Male / Female
1
M12 UN & CH
M15 UN & CH
M20.5 UN only
2P 2pin
4P 4pin
F Female (PSU Side)
5
4
30 30cm
60 60cm
100 100cm
6
Cable Length: Female with Cable 20 20cm
M15, M20.5 and M20.8 only have 2-pin choice
30 30cm
45 45cm
60 60cm
80 80cm
U1 SJTW (USA)
E1 H05RN-F (EURO)
Brand Name
Cable Length: Male with Cable
M20.8 CH only
No. of PIN
2
M Male (System Side)
UN UNICABLE (Made in Taiwan)
CH CHOGORI (Made in China)
100 100cm
►►Waterproof Cable Joiner 66 20
φ25
26
CJ04-1 suitable for 14AWG~16AWG CJ04-2 suitable for 18AWG~22AWG
Order No. : CJ04-1 CJ04-2 Up to four wires can be connected through this cable joiner by soldering or clamping by tools.
► CJ04 cable joiner can be purchased independently for user's own assembly.
26
• Decide a suitable wattage level, including safety margin. • Verify your design of LED driving circuit: direct drive by PSU [choose a constant current (C.C.) mode LED power supply] or add additional driving IC to get a more precise constant current level [choose LDD]. • Verify whether the application need PFC function. • Verify location of assembly and the required level against dust and humidity for the LED power supply (enclosure style, IP level, dry/damp/wet location). • Verify the required safety certificates. • Need to adjust the output voltage and/or output current or need the dimming function ?
► ►Su gg e s t e d S y s t e m D e s ig n Setting
Circuit Diagram
Description
Advantage & Disadvantage
Use constant
Using MEAN WELL's C.C. mode LED
Advantage
current (C.C.)
power supply as constant current
• Simplest design, no need LED
+V(Red)
mode power supply only
AC/DC C.C. mode PSU
-V(Black)
source and feed the LED arrays directly.
0.35A
... ...
0.35A
... ...
driver IC • Lower price • Higher efficiency with the
MEAN WELL product:
best lumen per watt(lm/w)
... ...
... ...
APC / LPC / ELN / PLN / PLC / LPF /
0.35A
HLN / PLD / PLM / CLG / CEN / HLG
Disadvantage
/ HLG-C / HSG / HVG / HVGC / HBG
• Unbalanced driving current
/ PLP / HLP / LCM families
... ...
and shorter LED life time • LED chips should be sorted for similar VF
Use constant voltage (C.V.) mode power
+V (Red)
AC/DC C.V. mode LED PSU
- V (Black)
Using AC/DC C.V. mode LED power
Advantage
supply and separate DC/DC LED
• Independent output
drivers.
current for paralleled LED
supply with +V Driver IC
-V
strips ...
• No need to sort the VF of LED
-V
• Longer LED lifetime
0.35A +V Driver IC
......
driver
0.35A +V
... ...
DC-DC LED
channels, the most balanced
Driver IC
• Failures in any string do not
...
affect the other strings
-V MEAN WELL product:
0.35A +V ...
-V
DC/DC LED Driver
Any AC/DC LED power supply+ LDD series (DC/DC LED driver)
Disadvantage • Higher price • Complicated circuit design • Lower system efficiency • L arger in power supply volume
27
Note At the moment of power on, the LED power supply will work in C.V. mode and can provide a peak output current; after the LED turns on, the LED power supply will go into C.C. mode (patent pending).
Metal Case NE W
NE W
PFC
Plastic Case
Constant Voltage + Constant Current (C.V.+C.C.) Note
PCB Type
Non-PFC
Constant Current
PFC
Plastic Case
Plastic Case
(C.C.)
NE W
PFC
U-bracket Metal Case
Constant Voltage (C.V.)
Non-PFC
28
NE W
Plastic Case
Series CEN-60/75 CEN-100
Dimension (Lx Wx H) 185x 62.5x 40.5 mm 195x 62.5x 40.5 mm
Page
Series CLG-60 CLG-100 CLG-150
Dimension (Lx Wx H) 195.6x 61.5x 38.8 mm 222.2x 68x 38.8 mm 229x 68x 38.8 mm
Page
Series HLG-40H/60H/60H-C HLG-80H/80H-C HLG-100H/120H/120H-C HLG-150H/185H/185H-C HLG-240H HLG-320H
Dimension (Lx Wx H) 171x 61.5x 36.8 mm 195.6x 61.5x 38.8 mm 220x 68x 38.8 mm 228x 68x 38.8 mm 251x 68x 38.8 mm 252x 90x 43.8 mm
Page 18/21 19/21 19/21 20/21 20 20
Series HVG(C)-100 HVG(C)-150
Dimension (Lx Wx H) 236x 68x 38.8 mm 245x 68x 38.8 mm
Page
Series HSG-70
Dimension (Lx Wx H) 127.2x 90x 38.8 mm
Page 23
Series HBG-100 HBG-160 HBG-240
Dimension (Dx H) 130x 66.5 151.68x 66.5 191.5x 69
Page
Series LPF-16(D)/25(D) LPF-40(D)/60(D) LPF-90(D) Series PLC-30 PLC-45/60 PLC-100
Dimension (Lx Wx H) 148x 40x 32 mm 162.5x 43x 32 mm 161x 61x 36 mm Dimension (Lx Wx H) 160x 46x 30 mm 181.5x 62x 35 mm 200.5x 69.5x 35 mm
Page
Series PLN-20 PLN-30 PLN-45/60 PLN-100
Dimension (Lx Wx H) 148.5x 38.5x 28 mm 145x 47x 30 mm 181x 61.5x 35 mm 200x 70.5x 35 mm
Page
Series HLN-40H/60H HLN-80H
Dimension (Lx Wx H) 161x 61.5x 35 mm 181x 61.5x 35 mm
Page
Series PLP-20 PLP-30 PLP-45/60
Dimension (Lx Wx H) 140x 32x 22 mm 101.6x 50.8x 26.6 mm 101.6x 50.8x 29.6 mm
Page
Series HLP-40H/60H HLP-80H
Dimension (Lx Wx H) 147x 53x 27 mm 167x 53x 29.5 mm
Page
Series APC-12/16 APC-25/35 Series LPLC-18, LPHC-18 LPC-20 LPC-35 LPC-60
Dimension (Lx Wx H) 77x 40x 29 mm 84x 57x 29.5 mm Dimension (Lx Wx H) 140x 30x 22 mm 118x 35x 26 mm 148x 40x 30 mm 162.5x 42.5x 32 mm
Page
Series ELN-30 ELN-60
Dimension (Lx Wx H) 145x 47x 30 mm 181x 61.5x 35 mm
Page
Series PCD-16/25 PCD-40/60 PLD-16/25 PLD-40/60
Dimension (Lx Wx H) 84x 57x 29.5 mm 128x 60x 31.5 mm 84x 57x 29.5 mm 128x 60x 31.5 mm
Page
Series PLM-12/25 PLM-40
Dimension (Lx Wx H) 145x 38x 22 mm 175x 42x 24 mm
Page
Series LCM-40(DA)/60(DA)
Dimension (Lx Wx H) 123.5x 81.5x 23 mm
Page 13 Page
16
17
22
25
9 Page 10
11
12
14
15
2 Page 4
5
6 7
8
Series
Dimension (Lx Wx H)
ULP-150
215x 67.4x 33 mm
Series APV-12/16 APV-25/35
Dimension (Lx Wx H) 77x 40x 29 mm 84x 57x 29.5 mm
Page
Series LPL-18, LPH-18 LPV-20 LPV-35 LPV-60 LPV-100
Dimension (Lx Wx H) 140x 30x 22 mm 118x 35x 26 mm 148x 40x 30 mm 162.5x 42.5x 32 mm 190x 52x 37 mm
Page
23
2
3
Family Type
Series Name HLG-40H / 60H / 80H / 100H / 120H / 150H / 185H / 240H / 320H
PFC (Note 1) (Note 3)
A B C (240W/320W only) Blank
Two Stage
AC Input Range (VAC)
Potted
90~305
C.C. or C.V.
C.V.+C.C.
D (option)
A HLG-60H-C/ 80H-C/ 120H-C/ B D (option) 185H-C A B HBGBlank 100/160/240 E (option, 100W/160W only) A HVG(C)-100/150 B D (option) HSG-70
CLG-150
Single Stage
A B C Blank
90~305
C.V.+C.C.
90~305
C.V.+C.C.
IP 65 67 67
Dimming Vo / Io Max. (Note 2) Adj Eff.
3 in 1
67
Timer
67 65 67 67
Timer
65 67
3 in 1
3 in 1
Warranty (years)
Remark
95%
5
Vo<60VDC
94%
5
Vo>60VDC
93.5%
5
Circular shape
91.5%
5
90%
3
91%
3
67 180~480 (528)
C.V.+C.C.
65 67 67
90~305
C.V.+C.C.
65
90~295
C.V.+C.C.
3 in 1 Timer Io
65 67 Resistance 67
CLG-100
90~295
C.V.+C.C.
67
88.5%
3
CLG-60
90~295
C.V.+C.C.
67
89%
3
CEN-60 / 75 / 100
90~295
C.V.+C.C.
66
91%
3
ULP-150
90~295
93%
3
91%
3
90.5%
3
A
HLN-40H / 60H / 80H
B
LPF-16 / 25 / 40 / 60 / 90
Blank
D
(half)
C.V.
Vo
90~305
C.V.+C.C.
64
90~305
C.V.+C.C.
(16W option)
67
3 in 1 3 in 1
PLN-100
90~295
C.V.+C.C.
64
88.5%
2
PLN-30 / 45 / 60
90~295
C.V.+C.C.
64
89%
2
PLN-20
90~277
C.V.+C.C.
64
83.5%
2
PLC-100
90~264
C.V.+C.C.
90%
2
PLC-30 / 45 / 60
90~264
C.V.+C.C.
89%
2
87%
3
88%
3
88%
2
PCD-16 / 25 / 40 / 60
PLD-16 / 25 / 40 / 60
A: 90~135 B: 180~295 16/40/60W: A-90~135 B-180~295
25W: 90~295
PLM-12/25/40 LCM-40 / 60 LCM-40DA / 60DA PLP-20 / 30 / 45 / 60 HLP-40H / 60H / 80H ELN-30 / 60 LPH / LPL-18 LPV-20 / 35 / 60 / 100 LPHC / LPLC-18 LPC-20 / 35 / 60 APC-12 / 16 / 25 / 35
(half)
(half)
90~295 180~295
30
C.C.
30
C.C.
30
C.C.
20W: 90~277 30~60W:90~264 90~305
20
AC Phase-Cut
0~10Vdc & PWM
92%
DALI & push DIM
91.5%
C.V.+C.C.
90~264 LPH: 180~264 LPL: 90~132 LPV: 90~264 LPHC: 180~264 LPLC: 90~132 LPC: 90~264 90~264
C.C.
Io
(16W/35W half)
Io
U-bracket
Terminal block I/O Terminal block I/O
3
Io level selectable in one power unit
89%
2
PCB type PCB type
C.V.+C.C.
3 in 1
90.5%
3
C.V.+C.C.
64
1~10Vdc or PWM
88%
2
C.V.
67
89%
2
C.V.+C.C.
67
87%
2
C.V.+C.C.
30
84%
2
90~264 C.V. 30 85% 2 (16W/35W half) Note 1 •S ingle-Stage PFC : No hold-up time and higher Ripple & Noise. Not to use in regions with unstable utility status is highly recommended. (For C.V. mode operation, please refer to the application Q&A on MEANWELL LED website.) • Two-Stage PFC : Longer hold-up time and lower Ripple & Noise. Suitable for LED lighting and general industrial applications. • Non-PFC : PF<0.6 and target at regions where PF compliance does not required. Note 2 3-in-1 dimming: 1~10Vdc, PWM signal, or resistance. Timer: Timmer dimming function, please contact MEANWELL for details. are popular models and will have sufficient stock for prompt delivery of high quantity orders. Note 3 APV-12 / 16 / 25 / 35
29
Ta iw an 明緯企業股份有限公司 MEAN W ELL ENTE R PR I SE S C O. , LTD. 248 9 1 新北市五股 區 五 權 三 路 2 8 號 No. 2 8 , W uqua n 3rd Rd., W u g u Dis t ., New Ta ipei C ity 2 4 8 9 1 , Ta iwa n ( R.O.C.) 統一編號:3 4 4 9 1 0 7 5 Te l :+8 8 6 - 2- 22 9 9 -6 1 0 0 ( rep.) Fa x :+88 6 - 2- 22 9 9 -6 2 0 0 ( rep.) +88 6 - 2- 22 9 8 -0 8 1 8 ( s a l es ) E-ma il:inf o@mea n wel l .c o m h t tp ://www. mea nwel l .c o m
C h ina
U .S.A .
明緯(廣州)電子有限公司
MEA N WEL L U S A , I N C.
MEAN WELL (GUANGZHOU) ELECTRONICS CO., LTD. 廣州市天河區東圃鎮黃 村 大 道 粵 安 工 業 園 A棟 2 樓 2nd Floor, No.A Bu il din g , Yu ea n In d. Pa rk , D ongp u Town, Tian h e Dis t ric t , G u a n g zh o u , Ch i na Post C ode: 51 0 6 6 0 Te l :+8 6 - 20 - 28 8 7 -1 2 0 0 4 0 0 -0 2 0 -1 2 0 0 ( 免 付 費 電 話 ) Fa x :+86 - 20 - 82 0 1 -0 5 0 7 E-ma il:inf o@mea n wel l .c o m.c n h t tp ://www. mea nwel l .c o m.c n
4 4 0 3 0 Fr e m ont B l v d . , Fr e m ont , C A 9 4 5 3 8 , U. S . A . Te l : + 1 - 5 1 0 - 6 8 3 - 8 8 8 6 Fa x : + 1 - 5 1 0 - 6 8 3 - 8 8 9 9 E- m a i l : i nfo@ m e a nw e l l usa . c om ht t p : / / w w w. m e a nw e l l usa . c om
蘇州明緯科技有限公司 S UZHOU MEAN WE L L TE C H N OLOGY C O. , LTD. 江蘇省蘇州市相城區黃 埭 鎮 潘 陽 工 業 園 東 橋 健 民 路 7 7號 No. 7 7 , Jia n- Ming Rd. Do n g -Q ia o , Pan-Ya ng Ind. Pa r k , H u a n g -Da i To wn , Xiang- C heng Distric t , Su zh o u , J ia n g -Su , Ch in a Post C ode: 21 5 1 5 2 Te l :+8 6 - 51 2 - 65 0 8 -8 6 0 0 Fa x :+86 - 51 2 - 65 0 8 -8 7 0 0 E-ma il:inf o@mea n wel l .c c h t tp ://www. mea nwel l .c c
E u rope MEA N WEL L EU R OP E B. V. L a ng s d e We r f 8 , 1 1 8 5 X T A m st e l v e e n, T he N e t he r l a nd s Te l : + 3 1 - 2 0 - 7 5 8 - 6 0 0 0 Fa x : + 3 1 - 2 0 - 7 5 8 - 6 0 0 1 E- m a i l : i nfo@ m e a nw e l l . e u ht t p : / / w w w. m e a nw e l l . e u
Ple ase C on ta ct Yo ur Lo ca l Di st r ib ut o r
www.meanwell.com This catalog is printed with soy ink