GENERAL SPECIFICATIONS
FREQUENCY RESPONSE CURVE
Nominal diameter
380 mm
Rated impedance
8 Ohm
AES power (1)
1500 W
Program power (2)
3000 W
Sensitivity (3)
95 dB
Max recomm. frequency
1500 Hz
(15 in)
Recomm. enclosure volume
100 ÷ 150 lt.
(3.53÷5.3 cu.ft)
Voice coil diameter
Dual 100mm
(Dual 4 in)
Voice coil winding material
Aluminum
Max Peak to Peak Excursion
66 mm
Suspension
Triple roll, Polycotton
Cone
(25,98 in) FREQUENCY RESPONSE MADE IN 125 LT. ENCLOSURE TUNED AT 50 Hz IN FREE FIELD (4π) ENVIRONMENT. ENCLOSURE CLOSES THE REAR OF THE DRIVER.
Straight ribbed, Water repellent
FREE AIR IMPEDANCE MAGNITUDE CURVE
THIELE SMALL PARAMETERS (4) Fs
42 Hz
Re
5,8 Ohm
Sd
0,0881 sqmt
Qms
6,3
Qes
0,41
Qts
0,39
Vas
94 lt
(3,31 cuft) (0,37 lb)
Mms
170 gr
BL
25Tm
Linear Mathematical X max (5)
± 9 mm
Le (1kHz)
1,70 mH
Ref. Efficiency 1W@1m (half space)
1,6 %
(136,56 sqin)
(± 0,35 in)
MOUNTING INFORMATIONS
NOTES
Overall diameter
393 mm
N. of mounting holes
8
Mounting hole diameter
7 mm
(15,47 in)
(0,28 in)
Bolt circle diameter
371 mm
(14,61 in)
Front mount baffle cutout diameter
354 mm
(13,94 in)
Rear mount baffle cutout diameter
360 mm
(14,17 in)
Total depth
245 mm
(9,65in)
Flange and gasket thickness
12,5 mm
(0,49 in)
Net weight
12,5 kg
(27,56 lb)
(1) AES power is determined according to AES2-1984 standard. (2) Program power rating is measured in 125 lit. enclosure tuned at 50Hz using a 40-400 Hz band limited pink noise test signal applied for 2 hours and with 50% duty cycle. (3) Sensitivity represents the averaged value of acoustic output as measured on the forward central axis of cone, at distance 1m from the baffle panel, when connected to 2.83V sine wave test signal swept between 100 Hz and 500 Hz with the test specimen mounted in the same enclosure as given for 2 above. (4) Thiele - Small parameters are measured after the test specimen has been conditioned by 1 hour 20 Hz sine and represent the expected long term parameters after a short period of use. (5) Linear Mat. Xmax is calculated as; (Hvc-Hg)/2 + Hg/4 where Hvc is the coil depth and Hg is gap depth.