Transcript
1.6 / 5.6
1.6 / 5.6 Series
FEATURES :
APPLICATIONS :
●
European design, 75 ohm version
●
Cable Assemblies
●
Snap-On with threaded coupling
●
Base Stations
mating
●
Datacom
Easy connection and disconnection
●
Telecom
●
www.misconnectors.com
[email protected]
1.6 / 5.6
ELECTRICAL SPECIFICATIONS Impedance
75 Ω
Frequency Range
0 – 1 GHz
Working Voltage
≥ 335 VRMS
Dielectric Withstanding Voltage 1000 VRMS at sea level VSWR
Straight : 1.15 max
Right Angle : 1.2 max
Contact Resistance
Center Contact : ≤ 4 mΩ
Outer Contact : ≤ 2 mΩ
Insulation Resistance
1,000 MΩ min.
MATERIAL SPECIFICATIONS Body and outer contacts
Brass, nickel or gold plated
Male contact
Brass, gold plated
Female contact
Beryllium Copper, gold plated
1.6 / 5.6
Insulator PTFE Crimp ferrule
Copper or brass, nickel or gold plated
MECHANICAL SPECIFICATIONS Contact Retention
≥ 6 lbs
Durability (matings)
500 cycles min.
ENVIRONENTAL Temperature Range
-40°C to +155°C
INTERFACE MATING DIMENSIONS
/HWWHU
-$&.
0LOOLPHWHUV 0LQLPXP
0D[LPXP
$
%
&
/HWWHU
0LOOLPHWHUV 0LQLPXP
0D[LPXP
$
%
&
'
'
(
(
)
*
1RWH,'WRPHHW96:5DQGFRQWDFWUHVLVWDQFH ZKHQPDWHGZLWKPPGLDSLQ
1.6 / 5.6
3/8*
1.6 / 5.6 Crimp Plug
Cable group : 03, 05, 10, 22, 23, 27
Clamp Plug
Cable group : 03, 05, 10, 22, 23, 27, 34, 35
Cable group : 03, 05, 10, 22, 23, 27
42
Right Angle Clamp Plug
Cable group : 03, 05, 10, 22, 23, 27,
34, 35
42
1.6 / 5.6
Right Angle Crimp Plug
Right Angle Bulkhead Crimp Jack
Cable group : 03, 05, 10
1.6 / 5.6
Bulkhead Clamp Jack
.91H
35 75 FLEX 3 36 75 FLEX 3.9 37 75 FLEX 5 38 50 3D-2V 39 50 5D-2V 40 50 8D-2V 41 50 5D-FB, LMR300
26 75 Belden 8218 27 75 BT-3002 28 50 .085/.086 semi-rigid, RG-405/U 29 50 .141 semi-rigid, RG-402/U 30 50 1.13mm OD micro-cable 31 50 1.32mm OD micro-cable 32 50 1.37mm OD micro-cable 33 50 .047 semi-rigid cable 34 75 FLEX 2
17 50 LMR400, Belden 9913 18 50 RG-8, 8A, 9, 213, 214 19 75 RG6/U, Quad 20 75 RG-11 21 75 Belden 1694A 22 75 AT&T 734A 23 75 AT&T 735A 24 50 LMR600 25 75 Belden 1695A
42
Bulkhead Crimp Jack
09 50 RG-58/U Plenum 10 75 RG-59, 62 11 75 RG-59/U 20AWG Center Conductor, Belden 1505A 12 75 Belden 8281 13 75 RG-59/U Quad Shield 14 75 RG-59/U Plenum 15 75 RG-6 16 50 8X, LMR240
Cable group : 03, 05, 10, 22, 23, 27,
Cable group : 03, 05, 10, 22, 23, 27,
01 50 RG-178, 196 02 50 RG-174, 188A, 316, LMR100 03 75 RG-179, 187 04 50 RD-316/U 05 75 RD-179/U 06 50 RG-58, 58A, 58C, 141, LMR195 07 50 RG-55, 142, 223, 400 08 50 LMR200
Right Angle Bulkhead Clamp Jack
34, 35
34, 35
34, 35
Cable group : 03, 05, 10, 22, 23, 27,
Cable Group Ω Cable Type
42
Golden Loch
1.6 / 5.6 Plug to Plug Adapter
Jack to Jack Bulkhead Adapter
.91H
1.6 / 5.6
42
3&'
Y-Link Adapter, Jack-Jack-Jack
1.6 / 5.6 3&' 42
U-Link Adapter, Plug-Plug
“T” Adapter, Jack-Plug-Jack
17 50 LMR400, Belden 9913 18 50 RG-8, 8A, 9, 213, 214 19 75 RG6/U, Quad 20 75 RG-11 21 75 Belden 1694A 22 75 AT&T 734A 23 75 AT&T 735A 24 50 LMR600 25 75 Belden 1695A
26 75 Belden 8218 27 75 BT-3002 28 50 .085/.086 semi-rigid, RG-405/U 29 50 .141 semi-rigid, RG-402/U 30 50 1.13mm OD micro-cable 31 50 1.32mm OD micro-cable 32 50 1.37mm OD micro-cable 33 50 .047 semi-rigid cable 34 75 FLEX 2
3&'
09 50 RG-58/U Plenum 10 75 RG-59, 62 11 75 RG-59/U 20AWG Center Conductor, Belden 1505A 12 75 Belden 8281 13 75 RG-59/U Quad Shield 14 75 RG-59/U Plenum 15 75 RG-6 16 50 8X, LMR240
01 50 RG-178, 196 02 50 RG-174, 188A, 316, LMR100 03 75 RG-179, 187 04 50 RD-316/U 05 75 RD-179/U 06 50 RG-58, 58A, 58C, 141, LMR195 07 50 RG-55, 142, 223, 400 08 50 LMR200
Cable Group Ω Cable Type
Golden Loch