Transcript
Install DIMM Memory Modules
DDR3 DIMM Memory Identification:
This server board supports up to 6 DDR3-800/1066/1333 ECC RDIMM or 1066/1333 ECC UDIMM.
A B C
DIMM A3 DIMM A2 DIMM A1 DIMM B3 DIMM B2 DIMM B1
DIMM notch and socket bump must align as shown.
D E
Memory Type: Minimum of one 1 GB, DDR3 800/1066/1333 MHz ECC RDIMM or 1066/1333 MHz ECC UDIMM.
Install Optical Drive and Hard Drive(s)
10
11
Connect Hard Drives/Optical Drive to Server Board
Note location of alignment notch. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. Push down firmly on the DIMM until it snaps into place and both levers close. IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot.
D
12
Attach Intrusion Switch Cable
4
0
3
Intrusion Switch Connector Internal USB/Serial Connector Detail
Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements.
See the documentation that came with your server chassis for add-in card installation.
Tab
13
Finishing Up
16
Network
Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power.
Software • BIOS, Drivers, and Operating System Installation
A. Confirm BIOS Version:
NIC1 10/100/ 1000 Mb
See your chassis documentation for AC power and grounding requirements.
Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://www.intel.com/support/motherboards/server/s3420gp If new versions are available, update the BIOS on your server. See the User Guide on the Intel® Server Deployment Toolkit CD for update instructions.
NIC2 10/100/ 1000 Mb
For the Intel® Server Chassis SC5650UP, see the Quick Start User's Guide accompanying the chassis.
B. Configure your RAID Controller: C. Install your Operating System: and with the operating system.
Use the instructions provided with the RAID controller.
Use the instructions provided with the RAID controller
D. Install Operating System Drivers: CAUTION: See your chassis documentation for AC power and grounding requirements.
Serial A
USB 0-1
Video
With the operating system running, insert the Intel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel® Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.
USB 2-3
Chassis Fan Connections
IMPORTANT NOTE: Return to your Intel® Server Chassis Quick Start User's Guide, or your non-Intel chassis documentation to finish installation and configuration of your Intel® Server Board S3420GP.
USB Connector Detail
USB 8-9
Begin cable connections at the SATA 0 location.
15
A
Front Panel
Server Board
CPU Power Connector Detail
Latch
USB 6-7
1
Install Add-in Card[s]
B
Note: For a non-Intel chassis, see your chassis documentation for front panel features and server board connection requirements.
Server Board
2
Server Board
Return to this document to finish up, including software, BIOS, drivers and operating system installation.
USB Floppy
Common Problems and Solutions
Attach fans with 4-pin connectors here.
For a non-Intel server chassis, see the "Making Connections ... Quick Reference" section below, and the documentation accompanying your chassis for specific chassis fan connection requirements.
For a list of hardware components that have been tested with this system, see: http://www.intel.com/support/motherboards/server/s3420gp/
The system does not boot or show video at power-on. • Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power. • Only Intel® Xeon® processors 3400 series with 95 W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel® Xeon® processors are not supported. Beep code 1-5-2-1 in a system means you do not have Intel® Xeon® processors 3400 sequence installed. • The system generates the memory error beep code and POST diagnostic LED message {0XE8~0XEE} that means some memory errors in early POST . • Remember, all DIMMs must be: • DDR3 800/1066/1333 MHz ECC Registered DIMM or 1066/1333 MHz ECC Unbuffered DIMM. • From the same manufacturer. • Installed beginning with DIMM A1. The system sometimes works, but is exhibiting erratic behavior.
Making Connections to the Server Board ... Quick Reference Required Connections A. B. C.
Note: Intel® Server Board S3420GPV does not have Status LED.
B
SATA 1 SATA 3 SATA 0
IPMB B B
B
CMOS Clear J1F5
Internal USB SSD
A
SAS Module Connector SATA_SGPIO
SYS_FAN 1 SYS_FAN 3 SYS_FAN 2 HSBP (not for Intel® Server Board S3420GPV) ® A Intel Server Board S3420GPLX only. Internal USB Floppy Connector B Intel® Server Board S3420GPLX and S3420GPLC.
CPU Fan 1
B
Available Documents Document/Tool
Content
Technical Product Specification In-depth technical information Spares, Parts List, and Configuration Guide Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Sever Configurator Tool Supported processors list Software and Drivers
Up-to-date firmware, driver and utility information
Additional Reference documents available at: http://www.intel.com/support/motherboards/ server/s3420gp/
I. J. K. L. M. N. O. P. Q.
C
12V CPU Power
A
6-7 USB
Intel® Server Chassis SC5650UP
HSBP (not for Intel® Server Board S3420GPV USB 6-9 SATA Connectors Serial B Chassis Intrusion Header IPMB SATA SGPIO Internal USB SSD SAS Module Header = Make this connection
Note: For a non-Intel Chassis, see your chassis documentation for server board connection information. Note: Not all optional connections are shown in this diagram. Refer to your Server Board User’s Guide, and your server chassis documentation for additional connection information.
J
8-9
Int. USB SSD
Serial ATA
P
K
DIMM B1
Optional Connections
Front Panel
DIMM B2
AXXSATADVD
System Fan 1 Header System Fan 2 Header System Fan 3 Header System Fan 4 Header CPU Fan Header = Make this connection
Main Power
Serial B
DIMM A1
D. E. F. G. H.
L
Intel® Server Chassis SC5650UP
DIMM B3
AXX4SASMOD
B
DIMM_B1
B
SATA 5 SATA 2 SATA 4
J1F2
CPU/System Fan Connections
Processor Socket
J1F3
Password Clear
AXXRMM3
A complete list of accessories and spares can be found at: http://www.intel.com/support/motherboards/server/s3420gp (search for the document titled “Spares and Configuration Guide”.)
CPU Fan Connector
Sys Fan 4
Intrusion
= Make this connection
AXXTIO
Additional Reference documents available at: http://www.intel.com/support/motherboards/server/s3420gp/
CPU Power Connector
CMOS Battery
® SAS Entry RAID Module
SATA Slim-Line DVD
DIMM_B2
BIOS Recovery
B
A
ATX I/O Shield
Intel
DIMM_A1
Internal USB
Intel RMM3 Connector
B
+12V CPU Power Connector Main Power Connector Front Panel Header
H
G
M
Accessories and Order Codes Intel® Remote Management Module 3
Main Power Connector
DIMM_A2
Internal USB
Diagnostic/ Status LEDs
Serial Port A
DIMM_A3
J1F1
A
NIC1 USB0 USB1
Video
SYS_FAN 4 Slot 6, PCI Express* Gen2 x8 (x16 Connector)
Note: Not all components, jumpers and connectors are described in this diagram. Refer to your Server Board User’s Guide on the Intel ® Server Deployment Toolkit CD for additional information.
ME Force Update
Front Panel Connector
A
Slot 5, PCI Express* Gen2 x8 (x8 Connector)
J1A2
NIC2 USB2 USB3
Slot 4, PCI Express* Gen2 x4 (x8 Connector)
Serial Port
Slot 1, 32 Mbit/33MHz PCI
BMC Force Update
B
Slot 3, PCI Express* Gen1 x4 (PCI Express* Gen2 Compliant)
B
Slot 2, PCI Express* Gen1 x1 (x4 Connector)
Note: Refer to the Technical Product Specification for Diagnostic LED decoder list.
DIMM_B3
Intel® Server Board S3420GP Component Layout
Intel® Server Chassis SC5650UP
DIMM A2
14
Attach the main power connector.
Serial B
5
SATA Data Cable Connector
B
Attach Front Panel, Serial, and USB Connections
Connect SATA Data Cables to server board here.
See the documentation that came with your server chassis for drive installation.
Attach the CPU power connector.
IMPORTANT NOTE: If you are using a non-Intel server chassis with an ATX power supply, see the documentation that came with your chassis for installation information.
B
A
A
Main Power Connector Detail
CAUTION: Note the location of the latch on each power cable connector and align it with the matching tab on each server board socket.
C
E
Note: For additional memory configurations, see the User Guide on the Intel® Server Deployment Toolkit CD that accompanied your Intel® Server Board S3420GP, or go to: http://www.intel.com/support/motherboards/server/s3420gp Memory sizing and configuration is supported only for qualified DIMMs approved by Intel®. For a list of supported memory, see the tested memory list at http://serverconfigurator.intel.com/default.aspx
Other Memory
Open both DIMM socket levers.
Server Board
DIMM A3
9
Make Server Board Power Connections
CAUTION: Avoid touching contacts when handling or installing DIMMs.
CAUTION: Observe normal ESD (ElectroStatic Discharge) procedures to avoid possible damage to system components.
DDR3
8
To Install DIMMs:
Memory Configurations and Population Order:
RMM3
Side 2
7
SAS Module
Q
USB Floppy HSBP
I
Sys Fan 3
SATA SGPIO
O
Sys Fan 1 IPMB
N
D
Sys Fan 2
E
F
IMPORTANT Note: Cables should be tied for better airflow. Use cable-ties as necessary.