16 Ton Submmy1924ht6ul 460v

   EMBED


Share

Transcript

SMMSi Twinned VRF Heat Pump Outdoor System HFGTYUT Model: MMY - AP1924HT6UL Submittal Data Unit – (s) #: SMMSi VRF Heat Pump Features • • • • • • • • • • Two of the 6, 8, and 10 Ton modules are twinned to form a larger system Modules have 2 or 3 inverter - driven, twin Rotary compressors Backup capability due to the multiple compressors Compressor speed is varied in increments of 0.1 Hz for comfort and efficiency Direct drive, inverter - driven outdoor motor with 64 steps 985 ft. (300 m) actual total system piping (liquid line) 590 ft. (180 m) actual piping length from outdoor unit to furthest fan coil Up to 330 ft. (100 m) outdoor control wiring Up to 6560 ft. (2000 m) control wiring between outdoor and indoor units Operating temperature range: o Cooling operating range DB: 23°F (-5°C) - 109°F (42.8°C) o Heating operating range WB: 5°F (-15°C) - 60°F (15.6°C) • Protection: High-pressure switch, Low-pressure sensor & switch, PC board fuse, Inverter Overload Protection • 7 Years limited compressor warranty, 1 Year limited parts warranty System Header Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MMY-MAP0964HT6UL Follower Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MMY-MAP0964HT6UL Nominal Cooling Capacity (Btu/h) . . . . . . . . . . . . . . . . . . . . . . . . . . . .192,000 Nominal Heating Capacity (Btu/h). . . . . . . . . . . . . . . . . . . . . . . . . . . . 216,000 Maximum Total Connected Indoor Unit Capacity . . . . . . . . . . . . . Up to 125% Cooling Efficiency* EER / IEER (Ducted FCU's) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.60 / 17.20 EER / IEER (Ductless FCU's) . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.60 / 17.20 EER / IEER (Ducted plus Ductless FCU's). . . . . . . . . . . . . . . . . 10.60 / 17.20 Heating Efficiency* COP @ 47°F / 17°F (Ducted FCU's) . . . . . . . . . . . . . . . . . . . . . . . .3.20 / 2.21 COP @ 47°F / 17°F (Ductless FCU's). . . . . . . . . . . . . . . . . . . . . . . 3.20 / 2.05 COP @ 47°F / 17°F (Ducted plus Ductless FCU's). . . . . . . . . . . . . 3.20 / 2.13 Electrical Power Source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460V, 3-Phase, 60Hz Minimum Circuit Amps (MCA)**. . . . . . . . . . . . . . . . . . . . . . . . . . (23 A / 23 A) Maximum Over Current Protection (MOCP)**. . . . . . . . . . . . . . . .(25 A / 25 A) Compressors Number x Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 x Inverter Twin Rotary Motor Output kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 x 2.1 Twinned System Sound Pressure Level Cooling / Heating dB(A). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 / 65 * Rated Per AHRI 1230 Standard Cooling: Indoor 80°F (35°C) DB / 67°F (27°C) WB, Outdoor 95°F (35°C) DB Heating: Indoor 70°F (21°C) DB, Outdoor 47°F (8°C) DB / 43°F (6°C) WB Physical Characteristics Color. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Munsell 1Y8.5/0.5 Physical Dimensions Header Inches . . . . . . . . . . . . . . . . . . . . 72 7/8 H x 47 9/16 W x 30 11/16 D Follower Inches . . . . . . . . . . . . . . . . . . . 72 7/8 H x 47 9/16 W x 30 11/16 D Header mm. . . . . . . . . . . . . . . . . . . . . . . . . . . .1851.7 H x 1209 W x 779.8 D Follower mm. . . . . . . . . . . . . . . . . . . . . . . . . . .1851.7 H x 1209 W x 779.8 D Header Net Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 817 lbs. / 370.6 kg Follower Net Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 817 lbs. / 370.6 kg Fan System Type x Quantity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Propeller x 2 Airflow Rate CFM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,600 + 6,600 Motor Type x Steps. . . . . . . . . . . . . . . . . . . . . . . . .Inverter Direct Driven x 64 Motor Output kW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 + 1.0 External Static Pressure (In WG)*** . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.20 Refrigerant / Piping Connections Factory Charge****. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 x 25.4 lbs / 11.5 kg Liquid (High Pressure) - Main*****. . . . . . . . . . . . . . . . . 5/8" / 15.9 mm (Flare) Suction (Low Pressure) - Main***** . . . . . . . . . . . . . 1 1/8" / 28.6 mm (Brazed) Balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8" / 9.5 mm (Flare) Required Accessory Twinning Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RBM-BT14UL ** Separate power supply is required. MCA and MOCP for both units are given *** Requires Setting by dip switches **** Additional Charges Required ***** Main pipe size leaving twinning kit DIMENSIONAL DRAWING - OUTDOOR UNIT COMBINATION Heat Pump / Twinned Unit Twinned Units Spacing between anchor bolt holes MMY-AP1924HT9UL MMY-AP1924HT6UL MMY-AP2284HT9UL MMY-AP2284HT6UL Outdoor unit (1) Header unit (2) Follower unit MMY-MAP0964HT9UL MMY-MAP0964HT9UL MMY-MAP0964HT6UL MMY-MAP0964HT6UL MMY-MAP1144HT9UL MMY-MAP1144HT9UL MMY-MAP1144HT6UL MMY-MAP1144HT6UL To outside flange Model 19.3" or more Spacing between anchor bolt holes (Slot) c Spacing between anchor bolt holes (490) NOTES: 1. A minimum clearance of 78.7” (2000 mm) is required above the unit. 2. Any wall or barrier should not exceed 31.5” (800 mm) from the bottom of the unit. 3. If the interconnecting pipe exits the front of outdoor unit, it must extend at least a minimum of 19.7” (500 mm) before it can turn 90o in either left or right direction. 4. Outdoor units are identified based on capacity (Header unit ≥ Follower unit ) DIMENSIONAL DRAWING - OUTDOOR UNIT To outdoor flange Spacing between anchor bolt holes NOTES: 1. A minimum clearance of 78.7” (2000 mm) is required above the unit. 2. Any wall or barrier should not exceed 31.5” (800 mm) from the bottom of the unit. 3. If the interconnecting pipe exits the front of outdoor unit, it must extend at least a minimum of 19.7” (500 mm) before it can turn 90o in either left or right direction. Spacing between anchor bolt holes Heat Pump / Single Unit Model: MMY--MAP0964HT9UL / MAP0964HT6UL Spacing between anchor bolt holes (Slot) 72.9" Spacing between anchor bolt holes Cut length of L-shape pipe Knockout for piping/wiring Liquid service valve connection port Discharge gas service valve conn. port Balance service valve connection port Square hole (for rigging) Knockout for piping (Plan view) Copyright 2014 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 10/14 02/14 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No:SUBMMY2164HT6UL---01 02 Replaces: NEW Replace: SUBMMY2164HT6UL-01